{"manifest":[{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYZD and MB4000JVYZC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3704312","datemodified":"2021-07-25T15:54:09","file_list":["cp048617.xml","cpqsetup.exe","payload.json","setup.dll","SMBPESD4.rel"],"md5sum":"43b5ea2fad33452a7c9e8b7d879aa7ad","name":"cp048617.exe","release":"2021-07-25T15:47:08","revision":"0","sha1sum":"d3606b852c1697153004de6f378beb5b7b734f15","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"29d3ee50608a4989be087dbfc8603ca4","version":"18fef078fcea4023bbe0f5929a33498c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYZD and MB4000JVYZC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB6000JVYZDおよびMB4000JVYZCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:19:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWBHR&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4887052","datemodified":"2021-07-23T08:39:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/CP048055.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/T14SEnD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e4c61fc63-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048055.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048055.scexe"],"md5sum":"dd17010309da23ad3e0695b0c11c7e22","name":"firmware-hdd-2e4c61fc63-HPD5-2.1.x86_64.rpm","release":"2021-07-23T08:27:05","revision":"0","sha1sum":"997b19ccfbe346b4e25801d007ae819749c42cc0","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"57c8ff295b854dbeaea4e204fed3ef83","version":"d0174a2937734bf79e3b7732622d4eff"},"installation":{"command":"CP040299.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T05:56:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3873520","datemodified":"2021-07-24T05:56:03","file_list":["cp048516.xml","cpqsetup.exe","payload.json","setup.dll","SKESTED9.rel"],"md5sum":"0c3a45301bdf6a9d9f8e3017fb46b088","name":"cp048516.exe","release":"2021-07-24T05:48:05","revision":"0","sha1sum":"0e6919eb3210071100cb8df2bfa76bcc085e32dc","size":"3MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"308794285e444711a0eb3833d54eb10e","version":"9b6a6a135c584e569a44a8007308be33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:51:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1615488","datemodified":"2021-08-27T05:25:49","file_list":["cp046782.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"82c9f2ae473dc47b1f547a48fef36254","name":"cp046782.exe","release":"2021-08-27T05:23:25","revision":"0","sha1sum":"30095b2950c86c675555c48d711a3309cf802dec","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"b2fc632eddf5428382301f3ae1e37ede","version":"804ee11f60b249f4bac2445a888e36f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.2.20</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where Input/Output (I/O) incompletions would be reported after extended periods of uptime in an Fibre Channel (FC) fabric doing Remote Desktop Protocol (RDP) requests</li>\n\t<li>Fixed a behavior where Multipath I/O (MPIO) paths may not recover if left offline for more than 90 seconds&nbsp;&nbsp;&nbsp;</li>\n\t<li>Fixed a behavior where an Fibre Channel (FC) Tape device configured for Target Persistent Binding would not be recognized after server reboot</li>\n\t<li>Fixed a behavior where Hyper-V Virtual Machines (VMs) may not see all paths to Logical Unit Numbers (LUNs)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMは、HPE Storageファイバーチャネルアダプターおよびメザニンホストバスアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5700739","datemodified":"2021-08-26T08:54:53","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"eb6be64154dbfb89dd4d805046adb8ba","name":"kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-4.rhel8u4.x86_64.rpm","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"3e2f544e21e6071e7bef1654f053531a25675023","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.01.a2-k1"}],"id":{"product":"a970944cf8a44d27bcff8a800d52aa6b","version":"abaa234ec94f4ae6899ce8215ce36471"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-1.rhel8u4.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"},{"lang":"ja","x_late":"<p>1.  システム管理者 (root) としてログインします。</p>\n\n<p>2.  RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3.  ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n                   <br />\n                    # rpm -Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh kmod-qlgc-qla2xxx-10.02.01.01.a2_k1-1.rhel8u4.x86_64.rpm<br />\n<br />\n4.  インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。  </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                      # rpm -e kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 4 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8 Update 4 Serverファイバーチャネルドライバーキットfor HPE QLogicホストバスアダプターおよびメザニンホストバスアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-30T11:02:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.4</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.01.a2-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.4</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.01.a2-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter on ESXi 6.5"},{"lang":"ja","x_late":"このパッケージには、ESXi 6.5上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプターをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27161395","datemodified":"2022-02-05T16:36:47","file_list":["/CP050329.vmexe","/CP050329.vmfile","/CP050329.xml","/CP050329_VMw.zip","/payload.json","/README.txt","/CP050329_VMw.zip/index.xml","/CP050329_VMw.zip/metadata.zip","/CP050329_VMw.zip/vendor-index.xml","/CP050329_VMw.zip/vib20/","/CP050329_VMw.zip/vib20/CP050329/","/CP050329_VMw.zip/vib20/CP050329/HPE_bootbank_CP050329_1.0.3-6.5.0.4240417.vib","/CP050329_VMw.zip/metadata.zip/vendor-index.xml","/CP050329_VMw.zip/metadata.zip/vmware.xml","/CP050329_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050329_1.0.3-6.5.0.4240417.xml","/CP050329_VMw.zip/metadata.zip/vibs/CP050329--3299395357655135445.xml"],"md5sum":"d8f24f6c997c8fd0cf530c67fc63ef38","name":"CP050329.zip","release":"2022-02-05T16:57:04","revision":"0","sha1sum":"d84d708b72a69553501672d156f27e13a4cef69b","size":"25MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP050329","version":"1.0.3-6.5.0.4240417"}]}],"id":{"product":"432284a4a7d540b6ab240935dd40f590","version":"7b732acd2bab46bb9155a83693812038"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline:</strong> &nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.<br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp;&nbsp; &nbsp;Download the appropriate SPP<br />\n&nbsp;&nbsp; &nbsp;Add the component to the SPP&nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp;&nbsp; &nbsp;Run SUM<br />\n&nbsp;&nbsp; &nbsp;Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp;&nbsp; &nbsp;For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp;&nbsp; &nbsp;Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp;&nbsp; &nbsp;Refer to the SPP documentation for detailed instructions at:www.hp.com/go/spp</p>\n\n<p style=\"margin-left:40px\"><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p><strong>To use HPE Insight Control for vCenter: </strong>&nbsp;<br />\n&nbsp;&nbsp; &nbsp;Log in to the vSphere Client &nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Click the HPE Insight Management tab&nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Follow Insight Control for vCenter steps to update firmware using a Smart Component<br />\n<br />\n<strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp;&nbsp; &nbsp;Enable SSH on the ESXi host<br />\n&nbsp;&nbsp; &nbsp;Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Place the Smart Component in a temporary directory<br />\n&nbsp;&nbsp;&nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp;&nbsp;&nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp;&nbsp;&nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp;&nbsp;&nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp;&nbsp; &nbsp;Logout.<br />\n&nbsp;&nbsp; &nbsp;Disable SSH&nbsp;on the ESXi host.<br />\n&nbsp;&nbsp; &nbsp;Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p><strong>オフライン：</strong>    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます。<br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />\n    適切なSPPをダウンロードします<br />\n    SPPにコンポーネントを追加します    <br />\n    更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとして更新対象のESXiホストを追加します  <br />\n    更新対象のESXiホストのIPまたはDNSアドレスを入力します  <br />\n    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください: http://www.hpe.com/go/spp</p>\n\n<p style=\"margin-left:40px\"><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong> <br />\n    vSphereクライアントにログインします     <br />\n    インベントリツリーのサーバーまたはクラスターを選択します  <br />\n    HPE Insight Managementタブをクリックします    <br />\n    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います<br />\n<br />\n<strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 </strong><br />\n    ESXiホストでSSHを有効にする<br />\n    rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 6.5）"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T07:18:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1014:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1200:</strong></p>\n\n<p>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.31.1014:</strong></p>\n\n<p>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). Note: If the port does not go up, switch to Force mode.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li>\n\t<li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following device&nbsp;has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB8000JFECQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5678202","datemodified":"2021-07-23T07:47:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/CP048175.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/SMKRPSD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-252770cdda-HPD7-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048175.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048175.scexe"],"md5sum":"dc2624e0c5da788f2e23150f8fb99e21","name":"firmware-hdd-252770cdda-HPD7-7.1.x86_64.rpm","release":"2021-07-23T07:34:12","revision":"0","sha1sum":"37e11489813126ab7b1550173fe0a0d6cc5085bc","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"cf9ee3d9e8f04b18823882812129b4e0","version":"85e64581f4844ae99247150add9ab062"},"installation":{"command":"CP040301.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:09:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen10Plusバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"3677792","datemodified":"2021-09-09T20:09:18","file_list":["cp049492.xml","cpqsetup.exe","Eaglescanyon-Release-0.39.bin.fw","payload.json","setup.dll"],"md5sum":"d79b9880722eb19b6b488ece06998ad6","name":"cp049492.exe","release":"2021-09-09T19:59:33","revision":"0","sha1sum":"4e487c0c08179920943a6864c1324c78fb1af65c","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39"}],"id":{"product":"b9dda486435f4c78a30de5b1c831c135","version":"9015687625a3473488cc42fd353f4fc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\packagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-08T18:36:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Product ID&#39;s to &quot;A4200 Gen10P LFF&quot; and &quot;A4200 Gen10P SFF&quot; to distinguish the generation.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"A4200 Gen10P SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"A4200 Gen10P LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.19.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2019およびWindows Server 2022で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"3134656","datemodified":"2021-08-26T11:25:05","file_list":["bcmnicfwupg.exe","BMAPIa.dll","cp048909.xml","cpqsetup.exe","FW/","FW/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"7427cd5b633fd21a61e3a04d05dff396","name":"cp048909.exe","release":"2021-09-17T00:00:00","revision":"1","sha1sum":"a7ddc83b0f8280a220e4d6fa9efacd65d5426a5b","size":"2MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"5.2.5.0"}],"id":{"product":"b0150fa8c3c74fa8a3415a136a3cc117","version":"581a6246de74473395c87a4c0375afdb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"214.0.0.0","description":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>\n\t<li>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n\t<li>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>\n\t<li>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</li>\n\t<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>\n\t<li>[インストール]ボタンをクリックして、インストールを開始します。</li>\n\t<li>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-23T02:06:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"BcmNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18890758","datemodified":"2021-08-26T15:05:09","file_list":["/CP048341_BUILD_2.data","/CP048341.vmexe","/CP048341.vmexe64","/CP048341.vmfile","/CP048341_VMw.zip","/CP048341.xml","/payload.json","/CP048341_VMw.zip/index.xml","/CP048341_VMw.zip/vendor-index.xml","/CP048341_VMw.zip/metadata.zip","/CP048341_VMw.zip/vib20/CP048341/HPE_bootbank_CP048341_HPD3.2-7.0.0.15843807.vib","/CP048341_VMw.zip/metadata.zip/vendor-index.xml","/CP048341_VMw.zip/metadata.zip/vmware.xml","/CP048341_VMw.zip/metadata.zip/vibs/CP048341--6959645046417752885.xml","/CP048341_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048341_HPD3.2-7.0.0.15843807.xml"],"md5sum":"afb2bacfe5de226f2041ad69299d2543","name":"CP048341.zip","release":"2021-08-26T14:59:46","revision":"0","sha1sum":"0e1a9b46b2aa384f22d00cb65f9080310bc2c05b","size":"18MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048341","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"a2bc84f793fd4972b6196baf3df85eb6","version":"198e704d96c8412d89b554415230b878"},"installation":{"command":"CP041510.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWUDB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T14:29:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 15 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"765715","datemodified":"2022-01-28T06:33:34","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"ad78c1fefba1b25ccc6b95997c5ada6d","name":"lsi-megaraid_sas-kmp-default-07.719.04.00_sles15sp2-1.x86_64.rpm","release":"2022-01-28T06:23:56","revision":"0","sha1sum":"498f2ea24f122bdfcab54be093e1656b3c5dcf59","size":"747KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.719.04.00"},{"bytes":"773435","datemodified":"2022-01-28T06:31:35","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"168955e76d457c3c32dc22cde08ba32a","name":"lsi-megaraid_sas-kmp-default-07.719.04.00_sles15sp3-1.x86_64.rpm","release":"2022-01-28T06:23:56","revision":"0","sha1sum":"9c6e17c37bd707e97ff7e6aad50a21b75e6c1faf","size":"755KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.719.04.00"}],"id":{"product":"506d73f1a1f34beeb329c1ead8b7d250","version":"44969dd99bfe42f7b8284da16ea77f82"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-11T06:34:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","latest_fixes_x_late":"<p>Addressed an issue with the Secure Boot enabled, after SLES OS installation update the megaraid_sas driver version from inbox to &ldquo;lsi-megaraid_sas-kmp-default-*_sles1*sp*-1.x86_64.rpm&rdquo; using the RPM file. In the next reboot Sles OS failed to boot to GUI login page.</p>\n\n<ul>\n\t<li>For additional information, reference SID8035</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Support Sles15sp3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5275209","datemodified":"2021-07-23T09:02:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/CP048195.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/G1633HD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4c048aaeb0-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048195.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048195.scexe"],"md5sum":"e25d2d0afe702d53da9cfe08b6b1b2c1","name":"firmware-hdd-4c048aaeb0-HPD8-4.1.x86_64.rpm","release":"2021-07-23T08:50:10","revision":"0","sha1sum":"f8fc36aad5e2b2ce8a8cff7161415eeef4c502c0","size":"5MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"3207ab7da97d4b129737d7c53c2ebb76","version":"2436129571374ec48c21bc0e26cbc074"},"installation":{"command":"CP042624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:41:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB014000GWUDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18956113","datemodified":"2021-08-26T14:41:29","file_list":["/CP048339_BUILD_2.data","/CP048339.vmexe","/CP048339.vmexe64","/CP048339.vmfile","/CP048339_VMw.zip","/CP048339.xml","/payload.json","/CP048339_VMw.zip/index.xml","/CP048339_VMw.zip/vendor-index.xml","/CP048339_VMw.zip/metadata.zip","/CP048339_VMw.zip/vib20/CP048339/HPE_bootbank_CP048339_HPG2.2-7.0.0.15843807.vib","/CP048339_VMw.zip/metadata.zip/vendor-index.xml","/CP048339_VMw.zip/metadata.zip/vmware.xml","/CP048339_VMw.zip/metadata.zip/vibs/CP048339-8592399725772804382.xml","/CP048339_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048339_HPG2.2-7.0.0.15843807.xml"],"md5sum":"7c2810ee9fe4555c3646d5e55c744b85","name":"CP048339.zip","release":"2021-08-26T14:36:22","revision":"0","sha1sum":"1f9b5d53ed16d56936165e901056bde2d4f97922","size":"18MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048339","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"eaadba373a2b4b7ab82c00e6e1f55628","version":"ff41fa60b1ff47ba92ced9071df729d2"},"installation":{"command":"CP041507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T12:36:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN, and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6219616","datemodified":"2021-07-24T11:14:50","file_list":["cp048479.xml","cpqsetup.exe","payload.json","setup.dll","spannsK4.rel"],"md5sum":"7b95fbb7a68d9084b8401172d2f7a6fc","name":"cp048479.exe","release":"2021-07-24T11:07:10","revision":"0","sha1sum":"8e46104d5b2ff30bb1fe26d317b45ddd142112db","size":"5MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d06d054af702418fa905eb8595ceb958","version":"4a9971b4e5f9496b9c87053d2cda135a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T18:32:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.00"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"5.00"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408e-m、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) -&nbsp;HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;3.53<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;3.21<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong>&nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;</p>\n\n<ul>\n\t<li style=\"list-style-type: disc;\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type: disc;\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type: disc;\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type: disc;\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type: disc;\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type: disc;\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type: disc;\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type: disc;\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type: disc;\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type: disc;\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type: disc;\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type: disc;\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type: disc;\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type: disc;\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6702176","datemodified":"2022-01-21T18:50:17","file_list":["cp049389.xml","cpqsetup.exe","HPE_luxor.bin.fw","payload.json","setup.dll"],"md5sum":"f64bef32547b9ac4838a09e37d433b53","name":"cp049389.exe","release":"2022-01-21T18:36:06","revision":"0","sha1sum":"b8b3dbaa92001ad83897bff4a02f4bd043a8f265","size":"6MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"5.00"}],"id":{"product":"5ace706167bb418f8ac30077c43e3171","version":"984c48b58fde48178dc493716faab312"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use HPE Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE Smart Array P408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-aおよびP416ie-m SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T16:08:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added OS support for Microsoft Windows Server 2022</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where SSD SmartPath is not enabled on logical drives created on the same array in certain scenarios.</li>\n\t<li>Fixed a problem where WRITE and READ fails with URE on a RAID6 volume where it could have completed successfully in certain error recovery scenarios.</li>\n\t<li>Fixed a problem where events were not getting logged in certain scenarios.</li>\n\t<li>Fixed an issue where a Windows memory dump process was taking longer than 30 minutes.</li>\n\t<li>Fixed a problem in Gen10+ server where FAULT LED was not turning on for the drives failing during device discovery.</li>\n\t<li>Fixed a problem where the critical event &quot;Controller memory ECC error limit exceeded&quot; was reported in the AHS IML log after upgrading to 3.53 B0 firmware build.</li>\n\t<li>Fixed a problem where the host WRITE I/O failed on the SmartCache logical drive with UREs present on the primary logical drive.</li>\n\t<li>Fixed an issue where the controller may be non-responsive after drive failure with SSD SmartPath enabled under a high queue depth workload.</li>\n\t<li>Fixed a performance issue when the host is submitting large sequential IO streams at high queue depth.</li>\n\t<li>Fixed an issue where OS filesystem is not available after making configuration changes in HII.</li>\n\t<li>Fixed an issue where error was observed while selecting edit SmartCache Logical drive option when SmartCache logical drive is in Degraded mode.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22374","datemodified":"2021-12-14T15:12:59","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"d471767edefe29e7ddfd5285780528de","name":"kmod-kernel-mft-mlnx-4.18.0-1.rhel8u4.x86_64.rpm","release":"2021-12-14T14:54:04","revision":"0","sha1sum":"09e304e50b9f578b7b4580f0c2ec42b93ff65ffb","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"},{"bytes":"7972302","datemodified":"2021-12-14T15:07:16","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/23","./usr/lib/.build-id/23/8e04ea9d1cf5e4d0bffa2a9ffa905215b11233","./usr/lib/.build-id/25","./usr/lib/.build-id/25/272a22133bc8f2bc269bd589dffd7cfe97b019","./usr/lib/.build-id/45","./usr/lib/.build-id/45/04084bdf52792335f6c316b8406200d7c3d2a5","./usr/lib/.build-id/77","./usr/lib/.build-id/77/f42cbb45647acdb6c1fbd09aa3dc4aae607096","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/d9336da78216d68defc4981c0181f49cc2ac1c","./usr/lib/.build-id/da","./usr/lib/.build-id/da/df0749c5859fdf544ff22ccaa1eb7b692eb3a6","./usr/lib/.build-id/df","./usr/lib/.build-id/df/da077576e46c79bb580489bd0bd52ff689cf44","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"d74a31da1310cd64e142ecd364c086b1","name":"mft-4.18.0-106.rhel8u4.x86_64.rpm","release":"2021-12-14T14:54:04","revision":"0","sha1sum":"c39682f856b8dfa00b258f49d2c2bbb2ef8beae4","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"}],"id":{"product":"deefa9a645fa441b8de838a7e800e6dd","version":"69d6da875a4d4745a6de7ecef16676cb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.18.0-1.rhel8u4.x86_64.rpm&nbsp;&nbsp;mft-4.18.0-78.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"953242","datemodified":"2021-01-14T07:50:15","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"6fa6a3fa29370b649c57c14326e6961a","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"034c8b07afcca0dc9fe2c1da7864a70ef57ebf44","size":"930KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"954112","datemodified":"2021-01-14T07:46:26","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"56b8c822abc0b5d74be445dd09575879","name":"kmod-be2iscsi-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:37:04","revision":"0","sha1sum":"b839c4a4d0d30f77a18e2958db4c06c1d0cb90bd","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1120be85411a4c4091bc1cad7f1e1af8","version":"38a828dcb5944a6f820916bfd8f83aa9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1693016","datemodified":"2021-11-02T14:56:08","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"0a576516bfb5e0a6f6512df79b5d2ea1","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel7u8.x86_64.rpm","release":"2021-11-02T13:36:23","revision":"0","sha1sum":"770b7f6876220904eca52fa9f22cb2482fb7e776","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"2255886","datemodified":"2021-11-02T15:00:35","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"347814f06e9ec49fc658eeaca36be9e0","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel7u8.x86_64.rpm","release":"2021-11-02T13:36:23","revision":"0","sha1sum":"24456e0aa843580a9f28420f160a175bd40f6e45","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"5ef718b94f9643ad8517d0050338c700","version":"238eb0f1a3eb4b139460fb931c37b0fb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"},{"lang":"ja","x_late":"<p>rootとしてログインし、rpmをご使用のハードディスク上のディレクトリにダウンロードし、そのディレクトリに移動します。<br />\n<br />\n<strong>注記</strong>：RoCEのユーザースペース機能を有効にするために、使用されているカーネルバージョンやタイプにかかわらず、\"mlnx-ofa_kernel-4.9\" RPMをインストールする必要があります。RoCEのユーザースペースライブラリであるRPM（mlnx-ofa_kernel）はOS配布に含まれるOpenMPI RPMと競合することがあります。これは既知の挙動です。Linux分布からのOpenMPI RPMは\"mlnx-ofa_kernel\"のインストレーションの前にはターゲットのノードにインストールされないことに注意が必要です。もし既にインストールされていれば、 HPE Mellanox RoCEのドライバーパッケージをインストールする前にすべてのOpenMPI配布のRPMをアンインストールしてください。 <br />\n<br />\nドライバーをインストールまたはアップグレードするには次のようにします。<br />\nカーネルバージョン3.10.0-1127.el7.x86_64または将来のerrataを使用している場合：<br />\n<br />\n<strong># rpm -Uvh kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nセットアップは完了しました。ドライバーを有効にするにはコンピューターを再起動します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HP Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_3p00_PLDMoMCTP_800095B8.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td>\n\t\t\t<td>800095B8</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"}],"files":[{"bytes":"10519800","datemodified":"2021-11-10T01:59:00","file_list":["HPE_E810_CQDA2_3p00_PLDMoMCTP_800095B8.HPb","HPE_E810_CQDA2_3p00_PLDMoMCTP_800095B8.xml","payload.json"],"md5sum":"0db712efc3db10e0ae855f85dfda0474","name":"HPE_E810_CQDA2_3p00_PLDMoMCTP_800095B8.fwpkg","release":"2021-11-10T01:53:44","revision":"0","sha1sum":"7665be7ce7bf89d70690638c77547ab166e24ee1","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159280860002"],"type_of_change":"1","version":"3.00"}],"id":{"product":"f3f8a4081d78499e9a2dd9c8d9fb4059","version":"fa85376c3a034da8b7935a284d44baae"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-03T10:21:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product correct an issue which the Operation failed error in POST when Breakout cable connected.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_CQ2_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. \n\nSSASCRIPTING - Scripting can be performed in offline or online environments.  The SSA Scripting application has 2 scripting modes – Capture and Input."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16639836","datemodified":"2022-01-24T11:25:29","file_list":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-5.30-6.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"md5sum":"29b72dd4262ffd26f47d1bb8aa5e6f3b","name":"ssacli-5.30-6.0.x86_64.rpm","release":"2022-01-24T11:22:57","revision":"0","sha1sum":"245bffbcee9ac5951de40293c8c6d5a82fc9c6cc","size":"15MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"51c52bf006bd4c60b09797563ff886bf","version":"1b5853f050a24da4be479f680e864efe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSACLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSACLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssacli and the executable name is ssacli which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:04:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication."},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"718357","datemodified":"2021-08-19T03:30:23","file_list":["/cp047396.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/index.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/vib20/testevent/HPE_bootbank_testevent_700.10.8.0.1-7.0.0.15843807.vib","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/vib20/hponcfg/HPE_bootbank_hponcfg_700.10.8.0.1-7.0.0.15843807.vib","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/vib20/conrep/HPE_bootbank_conrep_700.10.8.0.21-7.0.0.15843807.vib","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/vib20/bootcfg/HPE_bootbank_bootcfg_700.10.8.0.1-7.0.0.15843807.vib","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vmware.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vibs/bootcfg--7624848587451589441.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vibs/conrep--792564704199732962.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vibs/hponcfg-6698148441852477806.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/vibs/testevent--5270759171770812409.xml","/HPE-Utility-Component_10.8.0.700-22_18497760.zip/metadata.zip/bulletins/HPE-Utility-Component_10.8.0.700-22.xml"],"md5sum":"ff6a8483c852ad1b2e55596204be6b2e","name":"cp047396.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"2a26f64728b63ff9591ecde8b8950854cdb4db6e","size":"701KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9eca8969e05","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"testevent","version":"700.10.8.0.1-7.0.0.15843807"},{"name":"hponcfg","version":"700.10.8.0.1-7.0.0.15843807"},{"name":"conrep","version":"700.10.8.0.21-7.0.0.15843807"},{"name":"bootcfg","version":"700.10.8.0.1-7.0.0.15843807"}]}],"id":{"product":"60d50a2d8e934d7ba3009af9a701d8ce","version":"be3970e6ef0e47a9811a59889d919cf1"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 7.0"},{"lang":"ja","x_late":"HPEユーティリティバンドルSmartコンポーネント for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T22:38:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Includes an updated the Smart Storage Administrator CLI and CONREP</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Includes an updated the Smart Storage Administrator CLI and CONREP</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"testevent:700.10.8.0.1-7.0.0.15843807","sw_key_expectedpath":"software:vmware:zip"},{"name":"hponcfg:700.10.8.0.1-7.0.0.15843807","sw_key_expectedpath":"software:vmware:zip"},{"name":"HPE-Utility-Component:10.8.0.700-22","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"conrep:700.10.8.0.21-7.0.0.15843807","sw_key_expectedpath":"software:vmware:zip"},{"name":"bootcfg:700.10.8.0.1-7.0.0.15843807","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16601682","datemodified":"2021-08-27T12:35:52","file_list":["/CP048437_BUILD_3.data","/CP048437.vmexe","/CP048437.vmexe64","/CP048437.vmfile","/CP048437_VMw.zip","/CP048437.xml","/payload.json","/CP048437_VMw.zip/index.xml","/CP048437_VMw.zip/vendor-index.xml","/CP048437_VMw.zip/metadata.zip","/CP048437_VMw.zip/vib20/CP048437/HPE_bootbank_CP048437_HPD9.3-7.0.0.15843807.vib","/CP048437_VMw.zip/metadata.zip/vendor-index.xml","/CP048437_VMw.zip/metadata.zip/vmware.xml","/CP048437_VMw.zip/metadata.zip/vibs/CP048437-474269553684214630.xml","/CP048437_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048437_HPD9.3-7.0.0.15843807.xml"],"md5sum":"18a7f3e5959f7a4c8b867491b1c8c4b9","name":"CP048437.zip","release":"2021-08-27T12:30:51","revision":"0","sha1sum":"b9ae827729eb3d24e5528cd7252049c467b28b6b","size":"15MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048437","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"6b5a27285d114b399ac0db53bb209710","version":"8cd5c14d0d644d97a05775f03fc304f7"},"installation":{"command":"CP042219.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:13:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_32_1010-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHTアダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>2008This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter(P13188-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000416</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5270385","datemodified":"2021-12-21T06:02:52","file_list":["16_32_1010-MCX512F-ACH_Ax_Bx.pldm.signed","16_32_1010-MCX512F-ACH_Ax_Bx.pldm.xml","payload.json"],"md5sum":"bfbabe35560782e5a0b0b36f0261e5f2","name":"16_32_1010-MCX512F-ACH_Ax_Bx.pldm.fwpkg","release":"2021-12-21T05:58:45","revision":"0","sha1sum":"c38d83996c9672f54ee8074d6102fc61414cd560","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101715b30116"],"type_of_change":"1","version":"16.32.1010"}],"id":{"product":"0a8a267d13ac4d5588a19d1f0bcc2f5d","version":"84c21c08387f426cb61418a5c4cdab30"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX512F-ACHTアダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-21T05:57:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features included in Firmware version 16.31.2006:</strong></p>\n\n<ul>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF.\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>To enable it:</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p style=\"margin-left:96px\">PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF must be set to a none zero value.</p>\n\n<ul>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes included in firmware version 16.31.2006:</strong></p>\n\n<ul>\n\t<li>Altered the GetInventory NC-SI command to not report leading 0xf in firmware version when it starts with 0.</li>\n\t<li>Fixed PCIe lane margining capability issues.</li>\n\t<li>Fixed an issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"<p><strong>New Features and Changes included in Version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override).</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>Additional Fixes included in version 16.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX512F-ACHT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1266896","datemodified":"2021-07-23T14:48:39","file_list":["cp047039.xml","cpqsetup.exe","cp_data.xml","i40ea65.cat","i40ea65.din","i40ea65.inf","i40ea65.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"528f9da9a4394cd44e8effbda5f73712","name":"cp047039.exe","release":"2021-07-23T14:35:06","revision":"0","sha1sum":"3ebb0d7613b17529727a215fac3c0125225e3157","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"408cc9357d7a4fdb8b6243b952746726","version":"afa3575ccaae47dba19b76a89958dbcc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i40ea Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"i40ea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n"}],"files":[{"bytes":"7219008","datemodified":"2021-07-25T12:29:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/CP048239.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/GP1723b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fe9c474847-HPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048239.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048239.scexe"],"md5sum":"ddf0f171f4e3b82e7e02c40559261d6d","name":"firmware-hdd-fe9c474847-HPK3-3.1.x86_64.rpm","release":"2021-07-25T12:17:04","revision":"0","sha1sum":"a282cef4a6e3511a945e8b3f67f66c46c41c0ce5","size":"6MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"5bfad4d210f242bd90a5c8fa29d29f05","version":"9c5eb08b32f146a09e335f590c9c98b2"},"installation":{"command":"CP041314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T09:03:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 SP3."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 SP3で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"101615","datemodified":"2020-02-12T18:42:06","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/57ef6ded0ab349b14e94046722a43e0164dde6","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"0ea3dc41962b9194ccf67a9bd81fb603","name":"iscsiuio_bl-2.11.5.13-3.sles12sp3.x86_64.rpm","release":"2020-02-12T18:41:04","revision":"0","sha1sum":"1ee272253edaa7522a85410489597a367278c8e4","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"fdecd8de3b2448668fbc68e73736a3fc","version":"deac96d1c675459f8f95ac0aa828e2bb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"},{"lang":"ja","x_late":"HPE Blade QLogic iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 12 SP3"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product addresses an&nbsp;iSCSI discovery failure with VLAN.</p>\n\n<p>This product addresses an issue where&nbsp;an iSCSI portal is&nbsp;discovered with invalid an VLAN ID.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM4_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM4ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2227096","datemodified":"2022-01-17T15:18:35","file_list":["cp050757.xml","cpqsetup.exe","payload.json","setup.dll","UBM4_V1.24.hex.fw"],"md5sum":"b347600f9bd8e3d7effabbc24902ea31","name":"cp050757.exe","release":"2022-01-17T15:00:14","revision":"0","sha1sum":"cd7a840417a7494b6f6edde3cbb3f39686daa1fc","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.24"}],"id":{"product":"091f1e01734d4924a66d971602e115bc","version":"83cf7ade31de4ebbb9ca1b4483d6f681"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM4 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10Plus UBM4 バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"2048"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:43:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG2"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG2"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG2"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7944536","datemodified":"2021-12-20T07:10:37","file_list":["cp050580.xml","cpqsetup.exe","K511HPG2.rel","payload.json","setup.dll"],"md5sum":"81b63bfa76ef4601cbdda1146ae1ff5e","name":"cp050580.exe","release":"2021-12-20T07:02:43","revision":"0","sha1sum":"123f0ff413e4fb2a2f66201c9d9d8c6e0932b389","size":"7MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"2a95310f5de64c9fad6c33cfacf5d307","version":"d5279e620339469fab1604712d4a50fc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-20T06:59:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18199095","datemodified":"2021-08-30T18:55:12","file_list":["/CP048302_BUILD_8.data","/CP048302.vmexe","/CP048302.vmexe64","/CP048302.vmfile","/CP048302_VMw.zip","/CP048302.xml","/payload.json","/CP048302_VMw.zip/index.xml","/CP048302_VMw.zip/vendor-index.xml","/CP048302_VMw.zip/metadata.zip","/CP048302_VMw.zip/vib20/CP048302/HPE_bootbank_CP048302_HPG6.8-7.0.0.15843807.vib","/CP048302_VMw.zip/metadata.zip/vendor-index.xml","/CP048302_VMw.zip/metadata.zip/vmware.xml","/CP048302_VMw.zip/metadata.zip/vibs/CP048302-3566367639286406938.xml","/CP048302_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048302_HPG6.8-7.0.0.15843807.xml"],"md5sum":"d19f15a081859eb76b7a5b463494b6d1","name":"CP048302.zip","release":"2021-08-30T18:50:19","revision":"0","sha1sum":"ecc98d59b4ad46c1ce404324bf268833194c1af9","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048302","version":"HPG6.8-7.0.0.15843807"}]}],"id":{"product":"25298d41e8ae4c7a847f78be945ec24d","version":"0ab24257452b4a809cb343a2d29d105e"},"installation":{"command":"CP040785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T11:31:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1382285","datemodified":"2021-12-13T21:01:49","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"f38af4b950da33fa593c6418ea5b2d0b","name":"kmod-mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel7u9.x86_64.rpm","release":"2021-12-13T20:03:05","revision":"0","sha1sum":"ec04da4339e8d0eb7233d10520622fb25ac214bc","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"},{"bytes":"1347193","datemodified":"2021-12-13T21:04:35","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.17","./usr/share/doc/dpcp-1.1.17/README","./usr/share/doc/libibverbs-55mlnx37","./usr/share/doc/libibverbs-55mlnx37/libibverbs.md","./usr/share/doc/librdmacm-55mlnx37","./usr/share/doc/librdmacm-55mlnx37/librdmacm.md","./usr/share/doc/libvma-9.4.0","./usr/share/doc/libvma-9.4.0/CHANGES","./usr/share/doc/libvma-9.4.0/README","./usr/share/doc/mlnx-tools-5.2.0","./usr/share/doc/mlnx-tools-5.2.0/ib2ib_setup.txt","./usr/share/doc/rdma-core-55mlnx37","./usr/share/doc/rdma-core-55mlnx37/COPYING.BSD_FB","./usr/share/doc/rdma-core-55mlnx37/COPYING.BSD_MIT","./usr/share/doc/rdma-core-55mlnx37/COPYING.GPL2","./usr/share/doc/rdma-core-55mlnx37/COPYING.md","./usr/share/doc/rdma-core-55mlnx37/README.md","./usr/share/doc/rdma-core-55mlnx37/tag_matching.md","./usr/share/doc/rdma-core-55mlnx37/udev.md","./usr/share/licenses/dpcp-1.1.17","./usr/share/licenses/dpcp-1.1.17/LICENSE","./usr/share/licenses/libvma-9.4.0","./usr/share/licenses/libvma-9.4.0/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"1265ba88e1334f0b5e351a4bfd307793","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel7u9.x86_64.rpm","release":"2021-12-13T20:03:05","revision":"0","sha1sum":"a132bec0a34113bd277994b3b73f8e66ee543951","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"}],"id":{"product":"ac732738370b4df180761b2b7435b65d","version":"4558d107b07244909e9fc71110eaab88"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1</strong><strong>.rhel7u9.x86_64.rpm mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 9 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2834680","datemodified":"2021-07-22T11:38:01","file_list":["4IDVHPG1.rel","cp048635.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"eec88631f0135bcaa8e4a7aa4320241c","name":"cp048635.exe","release":"2021-07-22T11:29:07","revision":"0","sha1sum":"08e31ea5299d421250d9235412e0a3cbc7e20d71","size":"2MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"ea55ec7473304ea29dd406dfd2137028","version":"70ccb44535494a9684a969c153cc001f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:58:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEXYA and MB6000JEXYB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3028648","datemodified":"2021-07-25T15:09:14","file_list":["cp048609.xml","cpqsetup.exe","payload.json","setup.dll","TTMRESD9.REL"],"md5sum":"2bfa591801d762dcd0acb7bac6b7bb83","name":"cp048609.exe","release":"2021-07-25T15:02:07","revision":"0","sha1sum":"64a550a4ae85c2b34726afc66bdf043d8d5da75f","size":"2MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"705c5706f7b64a23bc5fcf7fbd4a5be7","version":"dd88875ae72949c6b4dfd68c6365be93"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:13:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"426469","datemodified":"2021-08-27T06:16:56","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"b1a1b4d8e65ca61c65d9c2c81bde1094","name":"brcmfcoe-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-27T06:11:06","revision":"0","sha1sum":"7fc3285290f2536ca9b318cd00c45d19ce8f065a","size":"416KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"81798df39029402e8ad9bf5a76183ca6","version":"8b2b31c1ace1475d9b3c9335d85b63f8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles15sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 service pack 2 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:12:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for SLES 15 SP2</li>\n</ul>\n\n<p>Updated to Driver version 12.0.1342.0</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where cluster nodes could be evicted during Fibre Channel over Ethernet (FCoE) multipath failover as described in <a href=\"https://access.redhat.com/solutions/3136041\">https://access.redhat.com/solutions/3136041</a></li>\n\t<li>Fixed a behavior where Ethernet connections may not recover after a Virtual Connect (VC) interconnect module reboot</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"5038788","datemodified":"2021-07-23T10:22:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/CP048217.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/GPM1645ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048217.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048217.scexe"],"md5sum":"b11d41ab19b6c4ffe22f9cb07b04459e","name":"firmware-hdd-a07a420ed1-HPD4-2.1.x86_64.rpm","release":"2021-07-23T10:11:06","revision":"0","sha1sum":"cfa8115453b11006dd2e6c7bc4ec88ab128ba184","size":"4MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f12cb892007944f694736d03ec00543c","version":"b21d6124bcd04af3b5df7dee43d49cc1"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:37:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2019用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"906528","datemodified":"2020-06-12T10:45:28","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044562.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"49c6fa5346af463c999d04a805a12340","name":"cp044562.exe","release":"2020-06-12T10:32:05","revision":"0","sha1sum":"ace4876a411ff30399c36a4f9bb4bb25e919a870","size":"885KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"14ccfdf7a8d64255bce75290d1e21746","version":"299f3ac601a4460d9602ffd6fac4d9d8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains drivers for the Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2019 and Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントは、Broadcom NX1 1Gb Ethernetアダプターfor Microsoft Windows Server 2019およびWindows Server 2022を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"972576","datemodified":"2021-09-01T04:24:25","file_list":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp048940.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"bed1ef76154737760e99942854012bd5","name":"cp048940.exe","release":"2021-09-17T00:00:00","revision":"1","sha1sum":"6e9f0bbc5a5770a1939a23f2c2fe3c0fc8ad7cd9","size":"949KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"1","version":"219.0.1.0"}],"id":{"product":"84f4d8cbba034646b75e0fce6c455870","version":"c93a673006fd4a74b31c0aa696cdf3fa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>\n\t<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>\n\t<li>[インストール]ボタンをクリックして、インストールを開始します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"lang":"ja","x_late":"Broadcom NX1 1Gbドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-23T02:06:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"b57nd60a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-12.8.528.12-1//firmware//A12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3933488","datemodified":"2021-07-21T02:13:17","file_list":["cp046789.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.528.12-1/boot/","elxflashStandalone-windows-12.8.528.12-1/firmware/","elxflashStandalone-windows-12.8.528.12-1/firmware/A12852812.grp","elxflashStandalone-windows-12.8.528.12-1/win/","elxflashStandalone-windows-12.8.528.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.528.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.528.12-1/win/x64/","elxflashStandalone-windows-12.8.528.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.528.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.528.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.528.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.528.12-1/win/x64/WinLpCfg.exe","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"b3ea26bbf1a056d0e5765eec7487d2e2","name":"cp046789.exe","release":"2021-07-21T01:59:05","revision":"0","sha1sum":"065d56fd76444998af65de1f513903df0dea7557","size":"3MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"facf75b5c7944efda90a1807afad2c8a","version":"ddb0047406b6436ab7ac6e80b2dcc906"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Distributed Management Task Force (DMTF) &ndash; Platform Level Data Model (PLDM) Firmware Update to the SN1200E, SN1600E, and SN1610E</li>\n\t<li>The adapter will now reset to defaults when the user activates Hewlett Packard Enterprise (HPE) Secure Erase from Hewlett Packard Enterprise (HPE) intelligent provisioning</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior&nbsp;where the SN1600E would wrongly display an unwanted message when loading Unified Extensible Firmware Interface (UEFI) driver defaults</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100859","datemodified":"2021-01-14T07:19:25","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"2af0f156d813885ad60dd90dbf3c0913","name":"kmod-be2net-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"a66b7aaddc230597c9153aa9221b1e7d40eb1c2e","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100863","datemodified":"2021-01-14T07:23:05","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"8d03323d34aff4826670cd28a059346e","name":"kmod-be2net-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-01-14T07:13:05","revision":"0","sha1sum":"b9b8b6aeae0d006d85e816f05b9b69556bdbde31","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"47f79ff4032545a7bdbbbdab76c5b9b2","version":"d975e0a231f5496c80ea72988a8242ca"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and&nbsp;Red Hat Enterprise Linux 7 Update 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_32_1010-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 1-port QSFP28 MCX515A-CCAT PCIe3 x16 Adapter"},{"lang":"ja","x_late":"HPE Ethernet 100Gb 1ポートQSFP28 MCX515A-CCAT PCIe3 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter(P31246-B21)</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>MT_0000000591</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1ポートQSFP28 PCIe3 x16 MCX515A-CCATアダプター（P31246-B21）</td>\n\t\t\t<td>16.31.1014</td>\n\t\t\t<td>MT_0000000591</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"5563592","datemodified":"2021-12-07T09:56:07","file_list":["16_32_1010-MCX515A-CCA_HPE_Ax.pldm.signed","16_32_1010-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"249d4db76913af13057e1caf00a1045e","name":"16_32_1010-MCX515A-CCA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:53:10","revision":"0","sha1sum":"f0e695749b45e6fc23fa4672f00b5f108e06d73d","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101715900346"],"type_of_change":"1","version":"16.32.1010"}],"id":{"product":"96fe9c5a9b9741d5bcf4ae73623359e0","version":"90c2f2ae902045cbaeb7eb42bd4eced8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 MCX515A-CCAT PCIe3 x16 Adapter"},{"lang":"ja","x_late":"HPE Ethernet 100Gb 1ポートQSFP28 MCX515A-CCAT PCIe3 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>Additional Fixes included in version 16.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New Features and Changes included in Version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override).</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>Additional Fixes included in version 16.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX515A-CCAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"113138","datemodified":"2021-10-01T05:10:33","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"c22ae5b6673f64ca4698ce50a7d1f3cf","name":"tg3-kmp-default-3.139b_k5.3.18_57-2.sles15sp3.x86_64.rpm","release":"2021-10-01T05:02:08","revision":"0","sha1sum":"45a45628d3d398cdf0bd4c480fdb2c00cab0dd99","size":"110KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"},{"bytes":"113090","datemodified":"2021-10-01T05:14:44","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"9c5f0db7aa0f6eb7d0fd469fe4cea758","name":"tg3-kmp-default-3.139b_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-10-01T05:02:08","revision":"0","sha1sum":"bf94d8da0f291bcee8ec725a1f822e975032c11d","size":"110KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"8e8482d9e6e6494a8e54ec40143d190a","version":"026eaeb8a6cd451d9ec415a9a11e8e22"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</p>\n","latest_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5176056","datemodified":"2021-07-24T09:25:26","file_list":["cp048463.xml","cpqsetup.exe","KPE60X1GHPK3.rel","payload.json","setup.dll"],"md5sum":"468b96e10eca4f975a4056812099d939","name":"cp048463.exe","release":"2021-07-24T09:18:14","revision":"0","sha1sum":"68171b461bc620baf89171e93774365ee39ada86","size":"4MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"d026cab87ecf46f4a70676c4643d63f0","version":"373486e94cc940cda7f4fdcefb8fb608"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T12:11:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.56 (01/20/2022)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8532722","datemodified":"2022-01-26T06:02:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/CP050884.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/U48_2.56_01_20_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u48-2.56_2022_01_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050884.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050884.scexe"],"md5sum":"b7ad0b94339ef2b64eaf664ed1f7b4b5","name":"firmware-system-u48-2.56_2022_01_20-1.1.x86_64.rpm","release":"2022-01-26T05:56:57","revision":"0","sha1sum":"2e9bb091d02ed716a78e80f58d1d2db8f4ff1c00","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"2bd1c3f2d559498081c13ef5a6c74bb4","version":"cdadd7d04b30485d812fd5e2229eec51"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner<strong>.</strong></p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<strong></strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T05:33:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.\n\nNone<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Provides out of band management system with OS-level Agentless Management information and Active Health System events. "},{"lang":"cn","x_late":"提供具有操作系统级Agentless Management信息和Active Health系统事件的带外管理系统。 "},{"lang":"ja","x_late":"帯域管理システム以外を、OS-レベルエージェントレス管理情報とアクティブヘルスシステムのイベントで提供します。 "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[{"lang":"en","x_late":"<ul>\n\t<li>IML events marked as repaired in ILO will not be mirrored in Windows Event Log.</li>\n\t<li>Recommend user enables code integrity policy after AMS installed.</li>\n\t<li>If Windows Server 2016 Device Guard policy is enabled, AMS can be upgraded from an older version to a newer version,&nbsp; but it cannot be uninstalled.&nbsp; To uninstall AMS, the Device Guard policy needs to be temporarily disabled.</li>\n\t<li>AMS Control Panel applet &ldquo;SNMP&rdquo; tab does not show SNMP settings and does not allow test trap generation<br />\n\t&nbsp; when iLO5 encryption is set to SuiteB NSA mode.&nbsp; Please use iLO5-&gt;Management page as an alternate option</li>\n\t<li>AMS may exhibit slow memory consumption increase in Windows Task Manager. This is due to known WMI (Windows Management Instrumentation)&nbsp;issue in Microsoft Windows. It is expected be fixed in future Microsoft Windows updates or versions. To slow down memory consumption either:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1. Restart&nbsp; the AMS service (type &#39;net stop ams&#39; followed by &#39;net start ams&#39; in a command prompt) ...OR...</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2. Create a new DWORD registry value named PollInterval&nbsp;in registry&#39;s HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\Parameters and set its value to higher than decimal 300. This value will determine&nbsp; how often (in seconds)&nbsp;AMS&nbsp;reads data from WMI.</p>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>iLOで修復済みとマークされたIMLイベントは、Windowsイベントログでは反映されません。</li>\n\t<li>ユーザーはAMSのインストール後にコード整合性ポリシーを有効にすることを推奨します。</li>\n\t<li>Windows Server 2016 Device Guardポリシーが有効になっている場合は、AMSを古いバージョンから新しいバージョンにアップグレードできますが、AMSをアンインストールすることはできません。  AMSをアンインストールするには、Device Guardポリシーを一時的に無効にする必要があります。</li>\n\t<li>iLO5暗号化がSuiteB NSAモードに設定されているときは、AMSコントロールパネルアプレットの[SNMP]タブに<br />\n\t  SNMP設定が表示されず、テストトラップ生成が許可されません。  iLO5->マネジメントページを代替オプションとして使用してください</li>\n\t<li>AMSは、Windowsタスクマネージャーでゆっくりとしたメモリ消費量の増加を示す場合があります。これは、Microsoft WindowsのWMI（Windows Management Instrumentation）の既知の問題によるものです。今後のMicrosoft Windowsのアップデートまたはバージョンで修正される予定です。メモリ消費を遅くするには、次のいずれかを実行します。</li>\n</ul>\n\n<p>             1. AMSサービスを再起動します（コマンドプロンプトで'net stop ams'と入力し、次に'net start ams'と入力します）...または...</p>\n\n<p>             2. レジストリのHKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\hpeams\\ParametersにPollIntervalという名前の新しいDWORDレジストリ値を作成し、その値を10進数の300より大きい値に設定します。この値により、AMSがWMIからデータを読み取る頻度（秒単位）が決定されます。</p>\n"}],"files":[{"bytes":"8292248","datemodified":"2022-01-25T13:37:25","file_list":["ams.cab","ams.msi","cp049914.xml","cpqsetup.exe","install.xml","MergeModule2012.msi","multisetup.dll","SmaInstall.cab"],"md5sum":"867768ed7498100a3ab7d2ec383d6c7d","name":"cp049914.exe","release":"2022-01-25T13:34:50","revision":"0","sha1sum":"856135234440f3dc32f03175ffa1e545425c25f2","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"type_of_change":"0","version":"2.51.0.0"}],"id":{"product":"e9a54d5b255e4c18936eebffaaff1ccf","version":"971885ce6e0546fe9658386d3b2b6ebb"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the service installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてサービスのインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service for Microsoft Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T09:46:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support Intel Virtual RAID (SATA).</li>\n\t<li>Added support for new I/O cards.</li>\n\t<li>Removed hardware RAID NVMe devices in CpqSePCIeDiskEntry.</li>\n\t<li>Added support OS uptime information.</li>\n\t<li>Removed Broadcom and QLogic DLL files.</li>\n\t<li>Shorten the stop time and uninstall time.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Handled more running exceptions when AMS is querying iSCSI information.</li>\n\t<li>Fixed a crash issue when AMS is querying network information.</li>\n\t<li>Fixed incorrect bridging NIC information.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support installer.dll version in system software information.</li>\n\t<li>Enhanced disk overheat detection.</li>\n\t<li>Removed unnecessary conditions for the status of P824i-p MR Gen10 controller report.</li>\n\t<li>Corrected the source of cpqIdeAtaDiskSSDPercntEndrnceUsed for iLo displayed.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fine tune presenting capacity bytes in AHCI SATA.</li>\n\t<li>Fixed thread leaking issue.</li>\n\t<li>Fixed Windows will shut down caused by bogus temperature.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ams.exe","sw_key_expectedpath":"%ProgramFiles%\\OEM\\AMS\\service"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n\t<li>qfle3, version 1.1.17.0</li>\n</ul>\n"}],"files":[{"bytes":"1399141","datemodified":"2021-08-12T04:40:50","file_list":["/cp047831.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qcnic-478720060.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3f-1875916866.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3-876788810.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.17.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.59.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.25.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"570b64407a76faf148c8869a1fedc204","name":"cp047831.zip","release":"2021-08-12T04:37:35","revision":"0","sha1sum":"f1ae6ad5da339ecb7fbcc6791eccff31d7dafe5a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qfle3","version":"1.1.17.0-1OEM.650.0.0.4598673"},{"name":"qcnic","version":"1.0.59.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.25.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e3347115cdc54c64abafd1793b901484","version":"a90e9c15f47c4ed9a0eb1ac36f1a548f"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 6.5 U3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qfle3:1.1.17.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.59.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"101922","datemodified":"2019-12-20T07:01:42","file_list":["/cp042807.xml","/Release_Notes_lsi-mr3-7.706.09.00-1OEM.txt","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/vendor-index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/vib20/lsi-mr3/Avago_bootbank_lsi-mr3_7.706.09.00-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00.xml","/VMW-ESX-6.7.0-lsi_mr3-7.706.09.00-offline_bundle-12095481.zip/metadata.zip/vibs/lsi-mr3--1465933317.xml"],"md5sum":"317a52ca94781ab4a74603cee2d7fb76","name":"cp042807.zip","release":"2019-12-20T07:00:04","revision":"0","sha1sum":"74ce4b13adb8ce3349eecb65788ba7cbf062d31a","size":"99KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"0","version":"2019.12.13","vib_list":[{"name":"lsi-mr3","version":"7.706.09.00-1OEM.670.0.0.8169922"}]}],"id":{"product":"d348cc79cad0401481d553a1970ba39e","version":"50f027b03ab249ef9a76185694d24e43"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller (64-bit) Driver for vSphere 6.7 (Driver Component)"},{"lang":"ja","x_late":"vSphere 6.7用HPE SmartアレイP824i-p MRコントローラー（64ビット）ドライバー（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-13T10:42:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added VMware vSphere 6.7 OS support</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Addressed a vSAN Fault Tolerance test failure seen in JBOD mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-mr3:7.706.09.00-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3489120","datemodified":"2021-08-26T07:11:43","file_list":["cp049365.xml","cpqsetup.exe","payload.json","setup.dll","TARM5ALSHPD6.rel"],"md5sum":"a4308be18e8c731bc579d271b7f5622b","name":"cp049365.exe","release":"2021-08-26T07:03:42","revision":"0","sha1sum":"6700526fc67150b5fe1e69fa5bb9635ba288d5f3","size":"3MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"dd83343964ed4806840a86595ee2254d","version":"b4bc8f4a1bcb4c46b831da890608c6d2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T07:00:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050852.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2630968","datemodified":"2022-01-26T03:29:32","file_list":["cp050852.compsig","cp050852.zip","cp050854.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"126406bc7a8874603ba9ae9ac363a7ef","name":"cp050854.exe","release":"2022-01-26T03:28:04","revision":"0","sha1sum":"4fa59adb831aa96c1f8aced8a43c98e496b7ae67","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"8bd617958fd64494b0066602dc57ff65","version":"cf06d428f9c94d7abe743aba9b4b37d1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download cp047662.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cp047662.exe.&nbsp;<br />\n2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>Execute the file &nbsp;cp047662.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います。</strong><br />\n1.    cp047662.exeを、サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムにダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />\n2.    ファイル名を右クリックして、プロパティを選択します。<br />\n3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />\n4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />\n5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />\n6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />\n7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />\n        a.    ファームウェアを展開しないでください。<br />\n        b.    ファイルをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p>\n\n<p><br />\n<strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />\n1.    Microsoft Windows CRC/SHAツールを使用して、cp047662.exeのSHA256ハッシュ値を計算します。 <br />\n2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />\n•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />\n•    値が一致しない場合は、ファイルやその内容を展開しないでください。<br />\n•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />\n•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p>\n\n<p>cp047662.exeファイルを実行し、画面の指示に従ってインストールを完了してください。<br />\nドライバーのインストールが完了した後、サーバーを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:00:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx4 is the low level driver implementation for the ConnectX®-3 and ConnectX®-3 Pro adapters for VMware ESXi 6.5 Mellanox Ethernet Adapters."},{"lang":"ja","x_late":"nmlx4は、VMware ESXi 6.5 Mellanoxイーサーネットアダプター用ConnectX®-3およびConnectX®-3 Proアダプターの低レベルドライバー実装です。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2798457","datemodified":"2020-11-24T07:55:32","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip","/cp046261.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/doc/release_note_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.16.70.2-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-rdma-1214697530.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-en-1132928091.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/vibs/nmlx4-core--114843923.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_core-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_en-3.16.70.2.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-17024424.zip/MLNX-NATIVE-ESX-ConnectX-3_3.16.70.2-1OEM.650.0.0.4598673-offline_bundle-17024424.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx4_rdma-3.16.70.2.xml"],"md5sum":"8e137dace023b758639d11e15d219cdc","name":"cp046261.zip","release":"2020-11-24T07:53:10","revision":"0","sha1sum":"fcbe6c42a7eeafff1b7d123fe1e5504d5453e6d9","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-core","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-en","version":"3.16.70.2-1OEM.650.0.0.4598673"},{"name":"nmlx4-rdma","version":"3.16.70.2-1OEM.650.0.0.4598673"}]}],"id":{"product":"4fdb2c37f619467eb44cb380a68bf092","version":"26a0e9fca5e04cc2bbfae7a4598f52e4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx4_en Driver Component for VMware 6.5"},{"lang":"ja","x_late":"nmlx4_enドライバーコンポーネント for VMware 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in version 3.16.11.10:</strong></p>\n\n<ul>\n\t<li>Resolved an issue that caused the network adapter traffic to stop.</li>\n\t<li>Fixed an internal multicast loopback issue that broke LACP(Link Aggregation Control Protocol) bonding protocol.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-core:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-en:3.16.70.2-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEXXV Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GEXXVドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5246557","datemodified":"2021-07-23T07:32:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/CP048168.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/TTMRETG2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a629fcea59-HPG2-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048168.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048168.scexe"],"md5sum":"1495a8539dbdf9be0de67ec004e6a091","name":"firmware-hdd-a629fcea59-HPG2-10.1.x86_64.rpm","release":"2021-07-23T07:20:16","revision":"0","sha1sum":"8e3ccfa9468bc3cb3d607150c702742c5c264987","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"0514481c6d244017bb9549a474c6c48c","version":"ad613143fd14434fbb4f1d2ded920131"},"installation":{"command":"CP040292.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:41:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-mezzanine Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2039280","datemodified":"2021-08-27T05:41:27","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp046759.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"fbc4ae96aa666c54b9bf7cfdce4e1d6c","name":"cp046759.exe","release":"2021-08-27T05:38:31","revision":"0","sha1sum":"4dd8c5d764d5c07263901cbd2e763c6070379744","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"65745918a4694cd0a7c96fde04278213","version":"9455d484006f4cb3aa9cd665516c51cf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2016"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//A12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel Host Bus Adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11253141","datemodified":"2021-08-31T08:45:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/CP046788.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/elxflashStandalone-linux-12.8.528.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/firmware/A12852812.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-emulex-2021.10.01-1.14/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046788.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046788.scexe"],"md5sum":"4db3583887fd67b2e75bc508573c887a","name":"firmware-fc-mezz-emulex-2021.10.01-1.14.x86_64.rpm","release":"2021-08-31T08:33:15","revision":"0","sha1sum":"e54c1efd16ebeb10a22614e4beaf199d95e4b78f","size":"10MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"e498500c87604ddabe3d9c5c037f53fc","version":"dbab8c60f31442c384de2ed91f83a1df"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Distributed Management Task Force (DMTF) &ndash; Platform Level Data Model (PLDM) Firmware Update to the SN1200E, SN1600E, and SN1610E</li>\n\t<li>The adapter will now reset to defaults when the user activates Hewlett Packard Enterprise (HPE) Secure Erase from Hewlett Packard Enterprise (HPE) intelligent provisioning</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior&nbsp;where the SN1600E would wrongly display an unwanted message when loading Unified Extensible Firmware Interface (UEFI) driver defaults</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS2, provides Windows 64-bit support for HPE Smart Array P824i-p MR 64-bit controller"},{"lang":"ja","x_late":"このドライバーMegaSAS2は、HPE Smart Array P824i-p MR 64-bitコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1029040","datemodified":"2019-01-23T23:43:47","file_list":["cp034411.xml","cpqsetup.exe","generic.dll","install.xml","megasas2.cat","MegaSAS2.inf","megasas2.pdb","MegaSas2.sys","nodev.inf"],"md5sum":"b85d4500b6f10fa9e1ae6ad418816d98","name":"cp034411.exe","release":"2019-01-24T05:43:01","revision":"0","sha1sum":"735718453b2bc6179045b1d512120760f95b9185","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9d4f074d"],"type_of_change":"1","version":"6.714.18.0"}],"id":{"product":"6c37374d90434a8f868d8552b730c508","version":"aae90018c7554e92860cfe5209d9ceff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR 64-bit controller driver for Microsoft Windows 2016 edition."},{"lang":"ja","x_late":"Windows 2016エディション用HPE Smart Array P824i-p MR 64-bitコントローラードライバー。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-02-02T06:38:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MegaSas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers in bundle MRVL-E3-Ethernet-iSCSI-FCoE:3.0.143.0-1OEM.700.1.0.15843807:</p>\n\n<ul>\n\t<li>qcnic, version 2.0.59.0</li>\n\t<li>qfle3, version 1.4.17.0</li>\n\t<li>qfle3f, version 2.1.25.0</li>\n\t<li>qfle3i, version 2.1.8.0</li>\n</ul>\n"}],"files":[{"bytes":"1513197","datemodified":"2021-08-12T04:41:49","file_list":["/cp047630.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.59.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.8.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.25.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.17.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3-1191248098602857359.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3i--558247773911429780.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qfle3f--371781071515599867.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/vibs/qcnic-3768180827600800407.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807_18145216.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.143.0-1OEM.700.1.0.15843807.xml"],"md5sum":"00fc0c3c5f98ce773bed9522e3497ed4","name":"cp047630.zip","release":"2021-08-12T04:38:34","revision":"0","sha1sum":"bbff508c1ebdea1ca83509981dcaa12e4eb7d06f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qcnic","version":"2.0.59.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.8.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.25.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.17.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d2fcdefd57524f44b8d7ad99311fad8f","version":"da957069bc3740f69c87aa777f86386c"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.</p>\n","latest_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 U3.<br />\nThis product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen while collecting data dump.<br />\nThis product addessses a PSOD seen during uplink reset with failure conditions.<br />\nThis product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qfle3f:2.1.25.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.4.17.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:2.1.8.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.143.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qcnic:2.0.59.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>HPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong>.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"22027739","datemodified":"2021-08-30T07:34:30","file_list":["/CP049302_BUILD_1.data","/CP049302.vmexe","/CP049302.vmexe64","/CP049302.vmfile","/CP049302_VMw.zip","/CP049302.xml","/payload.json","/CP049302_VMw.zip/index.xml","/CP049302_VMw.zip/vendor-index.xml","/CP049302_VMw.zip/metadata.zip","/CP049302_VMw.zip/vib20/CP049302/HPE_bootbank_CP049302_HPK3.1-7.0.0.15843807.vib","/CP049302_VMw.zip/metadata.zip/vendor-index.xml","/CP049302_VMw.zip/metadata.zip/vmware.xml","/CP049302_VMw.zip/metadata.zip/vibs/CP049302--4795136500392460299.xml","/CP049302_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049302_HPK3.1-7.0.0.15843807.xml"],"md5sum":"b7c36ddfb119ddcd9fb9ba27ed7aa324","name":"CP049302.zip","release":"2021-08-30T07:29:27","revision":"0","sha1sum":"215d47497599ad8b59924da45ddf4ce2923e9fba","size":"21MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3","vib_list":[{"name":"CP049302","version":"HPK3.1-7.0.0.15843807"}]}],"id":{"product":"eacabd6c758c41759c1c132130d3f614","version":"240cec76249d46c081bea5cd76ab50c8"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T12:28:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEQNL and MB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17527652","datemodified":"2021-08-26T20:03:54","file_list":["/CP048368_BUILD_2.data","/CP048368.vmexe","/CP048368.vmexe64","/CP048368.vmfile","/CP048368_VMw.zip","/CP048368.xml","/payload.json","/CP048368_VMw.zip/index.xml","/CP048368_VMw.zip/vendor-index.xml","/CP048368_VMw.zip/metadata.zip","/CP048368_VMw.zip/vib20/CP048368/HPE_bootbank_CP048368_HPDB.2-7.0.0.15843807.vib","/CP048368_VMw.zip/metadata.zip/vendor-index.xml","/CP048368_VMw.zip/metadata.zip/vmware.xml","/CP048368_VMw.zip/metadata.zip/vibs/CP048368--6638341273484569961.xml","/CP048368_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048368_HPDB.2-7.0.0.15843807.xml"],"md5sum":"c92f082d83d5a1ead06de5759bd88f06","name":"CP048368.zip","release":"2021-08-26T19:58:30","revision":"0","sha1sum":"2a7b7c4e28e2c0742e128c28c76b49774fbae6a6","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP048368","version":"HPDB.2-7.0.0.15843807"}]}],"id":{"product":"dffb1787348c4681b9170fbc360355c9","version":"2410a722f1864073918a1550e3137a10"},"installation":{"command":"CP039424.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T19:43:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000GWJRRおよびMB008000GWJRTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4863329","datemodified":"2021-07-23T09:42:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/CP048210.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/TAMG06ACHPG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048210.scexe"],"md5sum":"dd2942389e506e08e89ffa006669842f","name":"firmware-hdd-c993b31232-HPG4-4.1.x86_64.rpm","release":"2021-07-23T09:30:09","revision":"0","sha1sum":"33a87d34044c0d8dae5e904f0a7ff899c6add0ae","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"87b9a1c22150406cbf61d6b300753282","version":"6c38566fd3b242d996050ef74e0f389c"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:53:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - &nbsp;ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4663851","datemodified":"2021-07-23T08:44:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/4ICSHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/CP048514.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c4355d15c4-4ICSHPK4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048514.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048514.scexe"],"md5sum":"f331e4bfd4384612550ce74b4c857e4e","name":"firmware-hdd-c4355d15c4-4ICSHPK4-3.1.x86_64.rpm","release":"2021-07-23T08:31:07","revision":"0","sha1sum":"6c3e141257d71f6baa9e70ab3fcf7bdd50cd00da","size":"4MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"id":{"product":"21d70f91419f44f0a429331de70ce506","version":"055d8cbe2bec45c980972fa75d8151a5"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:38:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMD enabled Intel VROC platform.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>\n\t<p>Fixed HPK3 drive reports incorrect Device ID issue.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001920KWZQRおよびVO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25282360","datemodified":"2021-08-27T04:27:36","file_list":["/CP048473_BUILD_3.data","/CP048473.vmexe","/CP048473.vmexe64","/CP048473.vmfile","/CP048473_VMw.zip","/CP048473.xml","/payload.json","/CP048473_VMw.zip/index.xml","/CP048473_VMw.zip/vendor-index.xml","/CP048473_VMw.zip/metadata.zip","/CP048473_VMw.zip/vib20/CP048473/HPE_bootbank_CP048473_HPK5.3-7.0.0.15843807.vib","/CP048473_VMw.zip/metadata.zip/vendor-index.xml","/CP048473_VMw.zip/metadata.zip/vmware.xml","/CP048473_VMw.zip/metadata.zip/vibs/CP048473-4202404720181768433.xml","/CP048473_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048473_HPK5.3-7.0.0.15843807.xml"],"md5sum":"340b1a86707d24cfefe1f8ec78ca4367","name":"CP048473.zip","release":"2021-08-27T04:22:26","revision":"0","sha1sum":"a752c8dbfc3ab0730832b31036adb76c1c93cc05","size":"24MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5","vib_list":[{"name":"CP048473","version":"HPK5.3-7.0.0.15843807"}]}],"id":{"product":"939eb4c97d9745fe9b103a023bb5c6ab","version":"dd2eec3d0b3e4eb88055f676c750f2ae"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:13:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"287697","datemodified":"2021-11-04T08:58:14","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/68","./usr/lib/.build-id/68/6da78a2789b12021743a9c51ab049abcf26bc9","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"b2d27fb63946dcf9b9afb204a7f0575d","name":"kmod-hp-i40e-2.17.4-1.rhel7u8.x86_64.rpm","release":"2021-11-04T08:45:36","revision":"0","sha1sum":"f49698e5dab86e5f12fa58f0fa12f3b3366b0806","size":"280KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.17.4-1"},{"bytes":"287700","datemodified":"2021-11-04T08:57:06","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/15","./usr/lib/.build-id/15/46e0cdd88d4f18e58751fc01589e696b2ae33f","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"c71b97f8677c39bf4f8a555da4242019","name":"kmod-hp-i40e-2.17.4-1.rhel7u9.x86_64.rpm","release":"2021-11-04T08:45:36","revision":"0","sha1sum":"cae0a96f848cf68e3efe7374d52e933c9afafaec","size":"280KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.17.4-1"}],"id":{"product":"3d448885a31a43a9b8495c6b5feb6d8e","version":"45b28c96be3147f3ad4a53be81e7fa69"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"Red Hat Enterprise Linux 7 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL360&nbsp;Gen10 Plus Server</li>\n\t<li>HPE ProLiant DL380&nbsp;Gen10 Plus Server&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where double count in crc_error and size_error counter.</li>\n\t<li>This product addresses an issue where ethtool status triggers a warning due to invalid size on veb_tc when veb-stats was enabled.</li>\n\t<li>This product addresses an issue where the kernel error message about PF reset failed.</li>\n\t<li>This product addresses an issue where the adapter LED is not blinking via ethtool command</li>\n\t<li>This product addresses an issue where physical functions cannot synchronize tpid setting</li>\n\t<li>This product addresses an issue where Linux kernel problem (kernel Oops) when Virtual Station Interface (VSI) reset.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EH000600JWCPF and EH000900JWCPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5739732","datemodified":"2021-07-23T08:19:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/CP048084.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/SKESTED9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048084.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048084.scexe"],"md5sum":"0f29aa37e355c102a36623e4282ccce2","name":"firmware-hdd-a05f29cef3-HPD9-2.1.x86_64.rpm","release":"2021-07-23T08:06:08","revision":"0","sha1sum":"fcf855b7439af09e2327a3246a6ae12f29d8ed04","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"365d207e25654d61b3829f731965d204","version":"c87573404f8a4121be2922a308346ff8"},"installation":{"command":"CP040712.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:15:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3214024","datemodified":"2021-07-25T21:25:55","file_list":["cp048660.xml","cpqsetup.exe","GP1633D9.rel","payload.json","setup.dll"],"md5sum":"f76e8bb47952e995e5a5567f8f576a80","name":"cp048660.exe","release":"2021-07-25T21:18:14","revision":"0","sha1sum":"0e0923e2d12e6a927006b9473a817d093cebe37b","size":"3MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"dc2f3874388f4d969828a39097a550e8","version":"66ea9ac1c02b4c39aa9c0eae29e6be28"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"},{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:48:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300060","languages":[{"lang":"tw","x_late":"驅動程式 ─ 視訊"},{"lang":"en","x_late":"Driver - Video"},{"lang":"ko","x_late":"드라이버 - 비디오"},{"lang":"ja","x_late":"ドライバ - ビデオ"},{"lang":"cn","x_late":"驱动程序 - 视频"}]}],"description":[{"lang":"en","x_late":"This component provides advanced video support for the Matrox G200eH3 video controller."},{"lang":"ja","x_late":"このコンポーネントは、Matrox G200eH3ビデオ コントローラー対応の高度なビデオ機能を提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"1610024","datemodified":"2021-08-11T07:49:06","file_list":["cp048496.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","MxG2hDO64.sys","mxg2hs16.cat","MxG2hS16.inf"],"md5sum":"56fceaf387b81c523c7bf2819a0127c6","name":"cp048496.exe","release":"2021-08-11T07:47:08","revision":"0","sha1sum":"a83a5e9f7c020dd3570b1823b5b70c79143cb614","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"type_of_change":"0","version":"9.15.1.248"}],"id":{"product":"f74d68169f04405fb74a2820e48df6f5","version":"492e0c06475f44deb67e517a3945ab82"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<P>Place the Smart Component in a temporary directory, then double-click it to run.</P>\n<P>Select \"Install\" to start extracting to a temporary location on the hard drive.</P>\n<P>Click the \"Install\" button to perform the driver installation.</P>"},{"lang":"ja","x_late":"<P>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</P>\n<P>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</P>\n<P>インストールボタンをクリックしてドライバーインストールを実行します。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"dev":"0538","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-0538159000e4","type":"pci","ven":"102B"},{"dev":"0538","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-102b-05381590027f","type":"pci","ven":"102B"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T02:53:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>TBD</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022</li>\n\t<li>Added support for Edgeline platforms</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"MxG2hDO64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong>&nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5247680","datemodified":"2021-07-23T09:47:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/CP048212.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/hbcpssssefd3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048212.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048212.scexe"],"md5sum":"54f749118ad77b31db9fba3da575c1e9","name":"firmware-hdd-ef93133161-HPD3-3.1.x86_64.rpm","release":"2021-07-23T09:34:11","revision":"0","sha1sum":"6e4b21b39b7c2d133edcc47d8af62a5632982408","size":"5MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"07a5f3ddb9bd4168818fb38406e49473","version":"4cc4081d6c2a4ecd91cd55c8a8d84d1f"},"installation":{"command":"CP040353.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:13:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5801358","datemodified":"2021-07-23T09:23:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/CP048204.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/SCIMARRNNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048204.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048204.scexe"],"md5sum":"e86d008e94d239c05360f4fd45353701","name":"firmware-hdd-adb3ab8147-HPD6-2.1.x86_64.rpm","release":"2021-07-23T09:11:11","revision":"0","sha1sum":"c9d59a51d15910b09c4e661443803d99ed992fb0","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"6559625804344daab70667e2f1b0b044","version":"76dcd51cb75c421d9076c5eb660cb2e2"},"installation":{"command":"CP043262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:27:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16803647","datemodified":"2022-01-17T06:50:11","file_list":["payload.json","U60_1.54_01_13_2022.signed.flash","U60_1.54_01_13_2022.xml"],"md5sum":"4702fbb5631228665f5450fab6912e92","name":"U60_1.54_01_13_2022.fwpkg","release":"2022-01-17T06:46:55","revision":"0","sha1sum":"5d996d633ca5ec5c7571cf5fc5d316d2f26f0a01","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"31e3c0de86a045739aadd70ea35e114f","version":"aaf3b71433214daa864d70f8c6b9048e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10 Plus サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T03:40:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"U60","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWFVKおよびMB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWFVK and MB006000JWFVL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16246945","datemodified":"2021-08-30T19:47:57","file_list":["/CP048320_BUILD_2.data","/CP048320.vmexe","/CP048320.vmexe64","/CP048320.vmfile","/CP048320_VMw.zip","/CP048320.xml","/payload.json","/CP048320_VMw.zip/index.xml","/CP048320_VMw.zip/vendor-index.xml","/CP048320_VMw.zip/metadata.zip","/CP048320_VMw.zip/vib20/CP048320/HPE_bootbank_CP048320_HPD4.2-7.0.0.15843807.vib","/CP048320_VMw.zip/metadata.zip/vendor-index.xml","/CP048320_VMw.zip/metadata.zip/vmware.xml","/CP048320_VMw.zip/metadata.zip/vibs/CP048320-6342785011101897965.xml","/CP048320_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048320_HPD4.2-7.0.0.15843807.xml"],"md5sum":"cf9165c04520ed9149a97eb4f7756dd5","name":"CP048320.zip","release":"2021-08-30T19:42:51","revision":"0","sha1sum":"7d68402bfafb305aa82c27e5a2b82ecc6542d40e","size":"15MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048320","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"0e268c49682a427da167d2f123ccafaf","version":"dbe348f31daf45369b747ac1388713af"},"installation":{"command":"CP041749.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T11:45:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34210712","datemodified":"2022-02-21T12:49:36","file_list":["A47_2.56_02_10_2022.signed.flash","cp050503.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"cffec0c7a0254e1257a52f3076ba2244","name":"cp050503.exe","release":"2022-02-21T12:47:31","revision":"0","sha1sum":"d05f677b6c76940a0646faea2afb14249e6dcc30","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"f25420df1f7142d3a5eccbf213f27251","version":"582b4895cd65406ca826c14c0a1995b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:42:25","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.7 Mellanox Ethernet driver for ConnectX-3(Pro) devices"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1321287","datemodified":"2020-11-24T07:55:38","file_list":["/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip","/cp046262.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/doc/release_note_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.pdf","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-core/MEL_bootbank_nmlx4-core_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-en/MEL_bootbank_nmlx4-en_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/vib20/nmlx4-rdma/MEL_bootbank_nmlx4-rdma_3.17.70.1-1OEM.670.0.0.8169922.vib","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-core-681000306.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-en-914539524.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/vibs/nmlx4-rdma-1057846885.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_en-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_rdma-3.17.70.1.xml","/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-15491048.zip/MLNX-NATIVE-ESX-ConnectX-3_3.17.70.1-1OEM.670.0.0-offline_bundle-15491048.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-nmlx4_core-3.17.70.1.xml"],"md5sum":"2298b30f04857c03d31e64ce539c1a80","name":"cp046262.zip","release":"2020-11-24T07:53:05","revision":"0","sha1sum":"9e2127c88c3d08bb5f8425c729ea6d564b6a703a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec34a24f7b","20a6e8e4-bf33-4c71-a6bf-d9ec50f64a40","20a6e8e4-bf33-4c71-a6bf-d9ec0427da2e"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmlx4-en","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-rdma","version":"3.17.70.1-1OEM.670.0.0.8169922"},{"name":"nmlx4-core","version":"3.17.70.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"5174bf3a7a274551a9858fbcf75b37fb","version":"b26f87fc452c4998972983352fad588a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"nmlx4_en driver component for VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1003","subdev":"1777","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c1777","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CF","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cf","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18D6","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18d6","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18cd","type":"pci","ven":"15B3"},{"dev":"1003","subdev":"18CE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1003103c18ce","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-11T12:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>No Fixes are included in version 3.17.70.1:</strong></p>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New features in version 3.17.70.1:</strong></p>\n\n<ul>\n\t<li>Adapter card&rsquo;s PSID is now displayed in the Privstats (Private statistics).</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx4-en:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-rdma:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx4-core:3.17.70.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11584138","datemodified":"2022-03-08T11:14:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/CP051170.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/U32_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051170.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051170.scexe"],"md5sum":"39061a1c30c1209d97757c130a5f1f07","name":"firmware-system-u32-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"d64f2e3c489aafafa512cdf6526d5f233ecf0083","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"ff5a3639b5c744a8ac2e4611ce9482ea","version":"680a35ba13d84fad891df7b9224e7fef"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:25","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.7."},{"lang":"ja","x_late":"このパッケージは、ESXi 6.7.上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28634815","datemodified":"2022-02-08T09:56:02","file_list":["/CP050369.vmexe","/CP050369.vmfile","/CP050369.xml","/CP050369_VMw.zip","/payload.json","/CP050369_VMw.zip/index.xml","/CP050369_VMw.zip/vendor-index.xml","/CP050369_VMw.zip/metadata.zip","/CP050369_VMw.zip/vib20/CP050369/HPE_bootbank_CP050369_1.0.4-6.7.0.7535516.vib","/CP050369_VMw.zip/metadata.zip/vendor-index.xml","/CP050369_VMw.zip/metadata.zip/vmware.xml","/CP050369_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050369_1.0.4-6.7.0.7535516.xml","/CP050369_VMw.zip/metadata.zip/vibs/CP050369-3671836567280614792.xml"],"md5sum":"accbe131a6d29bbd2c88f916909f8072","name":"CP050369.zip","release":"2022-02-08T10:14:30","revision":"0","sha1sum":"e7ab8cbaba2555d85bb23edae69ce6e90d1de25f","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP050369","version":"1.0.4-6.7.0.7535516"}]}],"id":{"product":"8f7bfcc1686841199a7eebcfc658f164","version":"06d06b12ffea43c1aca27aa110df2f17"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 6.7)"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T11:04:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)</li>\n\t<li>779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li>\n\t<li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following device has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"IEGen10Plus_1.0.0.20.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.20"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPS Innovation Engineファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8406109","datemodified":"2021-04-06T06:32:23","file_list":["IEGen10Plus_1.0.0.20.signed.bin","IEGen10Plus_1.0.0.20.xml","payload.json"],"md5sum":"09d8f777f3fd98f6afaed55026b66d87","name":"IEGen10Plus_1.0.0.20.fwpkg","release":"2021-06-10T00:00:00","revision":"1","sha1sum":"57af11fbff6d3a07516b38a3425970bcf749c53b","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.20"}],"id":{"product":"4c108242693848129dadc44c03c82865","version":"61ff5f9ffa7b41ff840f44a7d9173380"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ -  HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-18T08:41:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"IE-Gen10Plus","sw_key_expectedpath":"firmware:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV\n"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC およびMO001920JWWWV\n"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA,&nbsp; EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4864845","datemodified":"2021-07-26T20:08:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/CP049145.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/TAPM5ALLHPD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049145.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049145.scexe"],"md5sum":"436f3cd47f287ce14a753566190a127c","name":"firmware-hdd-9ad359dac1-HPD9-2.1.x86_64.rpm","release":"2021-07-26T19:56:05","revision":"0","sha1sum":"f10064fe9507e7ba04e8c8e28c8b01e57f807c5e","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"c47b4b11bb744418a62b9ae668fd0ea6","version":"0a69bcbbf12d49ffb4d07264f2d06007"},"installation":{"command":"CP040601.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネントfor Linux (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、 MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、 MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:48:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"838232","datemodified":"2022-01-25T15:26:13","file_list":["cp049620.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"md5sum":"4e351793a09cf43d39d28e6de159ca92","name":"cp049620.exe","release":"2022-01-25T15:11:48","revision":"0","sha1sum":"cc64a1aa6fc76652c2880227c07cdee9f1aa0911","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"type_of_change":"1","version":"2.1.241.0"}],"id":{"product":"e951bbca527f4f9f8a089c23c99574fe","version":"4874cdd8a6e14c91a35210d60a497668"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6083828","datemodified":"2021-07-23T08:05:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/CP048136.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/HLIBRHsseFD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6ec35faf90-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048136.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048136.scexe"],"md5sum":"a11f848d392f7845f92d6c7b460b130d","name":"firmware-hdd-6ec35faf90-HPD6-2.1.x86_64.rpm","release":"2021-07-23T07:52:08","revision":"0","sha1sum":"8965c06c7424e5faee075c4230dd4a8e3a7fde6a","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"21c2460d0eda43ee8d9561eb3baf6bcd","version":"d4c9001ad60341c5a4782815892a0715"},"installation":{"command":"CP040326.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:00:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":" This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD Flash Component for&nbsp;Windows (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n"}],"files":[{"bytes":"5045784","datemodified":"2021-12-21T07:31:48","file_list":["cp050550.xml","cpqsetup.exe","GP1725K1.rel","payload.json","setup.dll"],"md5sum":"d0ab4cbae45a062a94b34f3b54f66105","name":"cp050550.exe","release":"2021-12-21T07:24:23","revision":"0","sha1sum":"5e10ded229d0c198e11e5b8e4fce531a41cd54fe","size":"4MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPK1"}],"id":{"product":"81163fed551c4f30a0af9ef8c5746c3e","version":"db94c9939c274ad7a5a1deeecbffafe6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-16T05:24:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33602235","datemodified":"2022-03-08T13:19:57","file_list":["payload.json","U33_2.62_03_08_2022.signed.flash","U33_2.62_03_08_2022.xml"],"md5sum":"536777ce6cf8288b6d0538f1761d03b3","name":"U33_2.62_03_08_2022.fwpkg","release":"2022-03-08T13:15:30","revision":"0","sha1sum":"c33630fcf9ff0ce32095222ec7c08fa5d998fb0f","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"972a94402aa14188aa7633893c7137b6","version":"bbd5525a8489459f80af34116a4a9185"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:33:45","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1735720","datemodified":"2021-12-13T22:09:32","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"027f58a03010a545891fd7bf59c7e716","name":"kmod-mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel8u4.x86_64.rpm","release":"2021-12-13T21:05:05","revision":"0","sha1sum":"4efc3eb23a79ac717fbb71195d8c3975d1602781","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"},{"bytes":"1412499","datemodified":"2021-12-13T22:13:49","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/04","./usr/lib/.build-id/04/6ba2441a5c922374418c860c5eb618fecba1c5","./usr/lib/.build-id/31","./usr/lib/.build-id/31/46cd17aa3584e388787e0fa3298b8a293ff284","./usr/lib/.build-id/47","./usr/lib/.build-id/47/d65f0a67687d9bab4dc065ac3348763eac1d9b","./usr/lib/.build-id/4c","./usr/lib/.build-id/4c/7f92980529bba08b9e9aacfde880f67318884b","./usr/lib/.build-id/4c/8b8fa5b3453b39427a1f1b1939e7c99943c798","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/5aaac939f6cab71585b7b0f27a039ec17d175f","./usr/lib/.build-id/60","./usr/lib/.build-id/60/e646fe12b0c0b7120018e389360b025d689f2f","./usr/lib/.build-id/74","./usr/lib/.build-id/74/16ef2103c62be64593dfaf06843ec020dd9bdd","./usr/lib/.build-id/8f","./usr/lib/.build-id/8f/e5e5bda2e8ad1e11342fc27db8047c76ae8b9d","./usr/lib/.build-id/e7","./usr/lib/.build-id/e7/d24aa1fd6aa44d7953903c7908f5afd2504af6","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"924444fd62643277bac5c36b0638c6e7","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel8u4.x86_64.rpm","release":"2021-12-13T21:05:05","revision":"0","sha1sum":"2b4aec78aa5c41baab6c79133092cc1f4b2d1030","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"}],"id":{"product":"0531c6d1fe1a4b698169f8dcb578d331","version":"72b2df5afc5f4b7b8b4472d12950a885"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.rhel8u4.x86_64.rpm mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 4 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33594755","datemodified":"2022-02-21T05:19:32","file_list":["A40_2.56_02_10_2022.signed.flash","A40_2.56_02_10_2022.xml","payload.json"],"md5sum":"ce4422874091dc18445b9915a40b08b2","name":"A40_2.56_02_10_2022.fwpkg","release":"2022-02-21T05:14:40","revision":"0","sha1sum":"65b40d87428891e7ce889028422b49e24967364d","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"6f77f9ef4381482fb9f00a79ce325ab3","version":"c33643e0030742adb6408f98ed0cffd1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL385 Gen10（A40）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T04:08:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000JWDFD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6028268","datemodified":"2021-07-23T08:02:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/CP048140.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/HLEAHssseFD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048140.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048140.scexe"],"md5sum":"a783c3655588a6eeda1f03320f72a5f7","name":"firmware-hdd-aaf1014ede-HPD3-2.1.x86_64.rpm","release":"2021-07-23T07:50:12","revision":"0","sha1sum":"34cedd66b9a70a89632d34848c90a2eb0984bd4a","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"421cc08cc7bc4143866089180c719d3f","version":"1a03f51f4a224fe28f961f51e7b31394"},"installation":{"command":"CP040338.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:07:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"218.0.303000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Microsoft Windows Server 2019 and Windows Server 2022."},{"lang":"ja","x_late":"このパッケージには、Microsoft Windows Server 2019およびWindows Server 2022で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのブートコード、PXE、UMP、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9295136","datemodified":"2022-02-07T10:18:05","file_list":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp050626.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"7be85de08576e7cbec69de3c6bb9cadb","name":"cp050626.exe","release":"2022-02-07T10:08:58","revision":"0","sha1sum":"dba19ba253c795a593518ffd2dedf245c18e64e0","size":"8MB","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"a3ac88993616476a8dcf9b3fac5ea67c","version":"d5a6c76c5ad44d0c99f03385725fe51a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p> </p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップグレードする場合は、リビジョン履歴を参照し、必要なバージョンまで一つずつアップグレードしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-22T05:25:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where network interface could not be brought up under OS.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue a packet missing problem after some amounts of multicast UDP streams transmitted.</li>\n\t<li>This product addresses an issue the port identifier LED problem on HPE Ethernet 10Gb 2-port 535T Adapter .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"bcmefwupg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892966","datemodified":"2021-03-08T18:01:40","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"078f24ffb9ccfbf0ae6a565c9847cb60","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"b08a628ef5265116ee802c13d05745b33cc0005c","size":"872KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"871242","datemodified":"2021-03-08T18:13:31","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"c286e9edc89302d9b790c48c568f0f93","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T17:52:10","revision":"0","sha1sum":"3561023f17012264bb3f0f3feef4a604454ca46a","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"61d3db3934a9409ea2efff88ec08bbc6","version":"cab99dcef31246e79bbcb163a81e1b59"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWFUV and&nbsp;EG001200JWFVA&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4768691","datemodified":"2021-07-23T08:36:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/CP048063.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/T14SELD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f0c91d2fe3-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048063.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048063.scexe"],"md5sum":"2942f97acf3ff641ff52bcc8b5883b9f","name":"firmware-hdd-f0c91d2fe3-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:25:06","revision":"0","sha1sum":"5a5407fd75175ac2b7eac26859f78932ebf3b04c","size":"4MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"0d53f18d93f34c14a12850b4c4f5646a","version":"00fdf1adb672473e93675e958c607d8f"},"installation":{"command":"CP040324.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T09:44:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4117168","datemodified":"2021-07-26T06:32:30","file_list":["cp049052.xml","cpqsetup.exe","payload.json","setup.dll","SHPEEVANSSD2.rel"],"md5sum":"656f691714d52ba8644fa99b9e61082b","name":"cp049052.exe","release":"2021-07-26T06:24:07","revision":"0","sha1sum":"2e7a35d98cd577efbc698cdf5053b77efc185481","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"a25f1000baab4c289a20555c0f1143b1","version":"634ba474b82a41b5ad801db22f5b4de8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:26:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10 NVMe storage backplanes. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、ProLiant Gen10Plus NVMeストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"37566","datemodified":"2022-02-04T11:56:01","file_list":["ISS_NVMe_BP_PIC_flashV1B24.xml","ISS_NVMe_BP_PIC_flashV1B24_signed.hex","payload.json"],"md5sum":"5ec81eceb27c32639f82fa25ac89e63f","name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","release":"2022-02-04T11:52:54","revision":"0","sha1sum":"6c34e2c79f0a5fff7598083243f1d8d5344a7160","size":"36KB","target_guids":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"type_of_change":"1","version":"1.24"}],"id":{"product":"aa9211e645514db69ecc4a92d0863429","version":"27d0782143b647809ecb454abed66373"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10 NVMe Backplane PIC Firmware"},{"lang":"ja","x_late":"ファームウェアパッケージ - Gen10 NVMe Backplane PICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"NVMe Backplane","target_guid":"00000000-0000-0000-0000-00004e564d65","type":"pic"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-24T09:11:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Update&nbsp;the&nbsp;firmware to support git setting on ProLiant Gen10 NVMe storage backplanes.</li>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<p>Addressed an issue when deploying Gen10 NVMe Backplane PIC FWPKG component from SUM, user may see additional listing of FWPKG and Smart&nbsp;component if operate system&nbsp;is Windows or Linux</p>\n\n<ul>\n\t<li>For additional information, reference SID8029</li>\n\t<li>Please use FWPKG component to do installation</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Update&nbsp;the&nbsp;firmware to support git setting on ProLiant Gen10 NVMe storage backplanes.</li>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"NVMePIC-Gen10","sw_key_expectedpath":"firmware:nvmebackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD2"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD2"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD2"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD2"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD2"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD2"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD2"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD2"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD2"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD2"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD2"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ</p>\n\n<p><strong>リリースバージョンおよび/または日付：</strong><br />\n     HPD2<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     HPD1<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     HPD1<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"3763144","datemodified":"2021-12-09T07:42:34","file_list":["cp050385.xml","cpqsetup.exe","payload.json","setup.dll","TAPM6ALLHPD2.rel"],"md5sum":"5628f4eb068e2b4c38eaefbfb1166631","name":"cp050385.exe","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"2661e5c26900569b324fb0da0fe7f10f723921f9","size":"3MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"139d2679780d42b2a020c2a6176ac11b","version":"7538eb2bd14c416d842690cdd515dc65"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T10:49:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP2."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 15 SP2下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23150","datemodified":"2021-10-01T18:05:40","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"d205fb74bb9ae0a46fca913944d5ba73","name":"libbnxt_re-219.0.8.0-sles15sp2.x86_64.rpm","release":"2021-10-01T17:56:01","revision":"0","sha1sum":"753a03f351c9bb3f711c98872080ed26a4036d81","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"219.0.8.0"}],"id":{"product":"ae3d91fc556c4e44b780b594f473e350","version":"5ce0b8e7087c4669aa47239011dcba04"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">インボックスライブラリと競合する可能性のあるHPE Broadcom RoCEライブラリをインストールまたはアップデートするときは、--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP2"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15 SP2用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GVYYU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5280008","datemodified":"2021-07-23T07:31:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/CP048169.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/SMPN6TG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdc37cb37f-HPG2-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048169.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048169.scexe"],"md5sum":"d9254815a37ff8aa72a6cf1a41b6a094","name":"firmware-hdd-bdc37cb37f-HPG2-9.1.x86_64.rpm","release":"2021-07-23T07:19:15","revision":"0","sha1sum":"6ad381fbd87734eb38d9c457ca1b5eb9cbcec1ef","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ff74c7c5dcd8491d9c1177c5c1de73f4","version":"3ebfa78763694b1f93535e4e524b3efe"},"installation":{"command":"CP040310.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:47:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"17015336","datemodified":"2021-12-21T11:58:43","file_list":["/CP050057_BUILD_3.data","/CP050057.vmcfg","/CP050057.vmexe","/CP050057.vmexe64","/CP050057.vmfile","/CP050057_VMw.zip","/CP050057.xml","/payload.json","/CP050057_VMw.zip/index.xml","/CP050057_VMw.zip/vendor-index.xml","/CP050057_VMw.zip/metadata.zip","/CP050057_VMw.zip/vib20/CP050057/HPE_bootbank_CP050057_5.04.3-7.0.0.15843807.vib","/CP050057_VMw.zip/metadata.zip/vendor-index.xml","/CP050057_VMw.zip/metadata.zip/vmware.xml","/CP050057_VMw.zip/metadata.zip/vibs/CP050057--9079731622169830535.xml","/CP050057_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050057_5.04.3-7.0.0.15843807.xml"],"md5sum":"8059c9d4eba7e4b1fae02f63b80b0527","name":"CP050057.zip","release":"2021-12-21T11:57:03","revision":"0","sha1sum":"ab3830150d8f9ec437975cba73687a42d68de6ed","size":"16MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04","vib_list":[{"name":"CP050057","version":"5.04.3-7.0.0.15843807"}]}],"id":{"product":"cd60e68416444c61a56b3c63cb2d1ca3","version":"871dde98914c41cd841f48ca68f211a6"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:600px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"VMware (ESXi)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-24T08:32:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33593927","datemodified":"2022-02-21T05:12:43","file_list":["A41_2.56_02_10_2022.signed.flash","A41_2.56_02_10_2022.xml","payload.json"],"md5sum":"6de35f744c5842af3513287d03693401","name":"A41_2.56_02_10_2022.fwpkg","release":"2022-02-21T05:07:50","revision":"0","sha1sum":"c4e1e9ada09ee985a553794e06bbbe6f3d3172d1","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"14652a1a392747089da4a4254064ac9d","version":"52418fc45dba49f6bbf6a614446d4bd2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL325 Gen10（A41）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T06:06:43","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR および VK001600GWCNT ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR&nbsp;and VK001600GWCNT&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4690895","datemodified":"2021-07-23T10:41:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/4IDVHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/CP048185.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6e3845def5-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048185.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048185.scexe"],"md5sum":"aaee53f8fc1dbe0bb63f4073bcd08d25","name":"firmware-hdd-6e3845def5-HPG1-6.1.x86_64.rpm","release":"2021-07-23T10:28:04","revision":"0","sha1sum":"68c286c5ca0d583a56b3baed9191fbde38f8ab31","size":"4MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"bc34fe37ff6f4e0b9f7866222b805e05","version":"6c6e53607a1046918b40cfc9de16b04c"},"installation":{"command":"CP040345.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:54:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050885.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.062"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9036880","datemodified":"2022-01-26T08:31:32","file_list":["cp050885.compsig","cp050885.zip","cp050886.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"1a10e8196970a7cfc66e9f0cc765647b","name":"cp050886.exe","release":"2022-01-26T08:29:30","revision":"0","sha1sum":"481102e101780c486e8cc7c8febebad57e68d038","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.062"}],"id":{"product":"56422dc0cdb64171addc0c9909a7019a","version":"65ce49257ed44e9192b9a764444c0cf7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T08:26:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added support for Intel Optane Persistent Memory.</p><p><strong>Known Issues:</strong></p>None","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version of the System ROM contains updates aligned with the INTEL Whitley BKC WW52.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"SPS_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."},{"lang":"ja","x_late":"iLO 5自動サーバー復旧ドライバーは、オペレーティングシステムがロックアップした場合にサーバーをリセットするASRハードウェアタイマーを管理します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"590720","datemodified":"2021-09-07T14:03:39","file_list":["cp047942.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"md5sum":"4f1841510013ef52570e5ac768ae370d","name":"cp047942.exe","release":"2021-09-07T14:01:03","revision":"0","sha1sum":"b21be877f5f46dcab387269f9ac49d6439dfa4a2","size":"576KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"95e1a7b8a2664cd8b8d67128eff9bb87","version":"72d6a58075614569b9b4ab1ec2e5b9cf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2016 and Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-14T07:33:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Snap5 platforms</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nechesasr.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33588613","datemodified":"2022-02-07T07:33:42","file_list":["payload.json","U46_1.58_01_13_2022.signed.flash","U46_1.58_01_13_2022.xml"],"md5sum":"4a7596bf3b649bcc5a19cfcec20d38e2","name":"U46_1.58_01_13_2022.fwpkg","release":"2022-02-07T07:30:28","revision":"0","sha1sum":"0f44eca314518db0c135c70bbdc25b84e8befd85","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"d8cf5e47a4564ba6bcb2ea1177a33ff1","version":"7a553a8e06164ab891e08145e0f061d3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"lang":"ja","x_late":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-22T03:07:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"U46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含的驅動程式適用於在 Windows Server 2016 執行的 HPE Intel E1R Gigabit Ethernet NIC。"},{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel E1R 기가비트 이더넷 NIC용 드라이버가 들어 있습니다."},{"lang":"cn","x_late":"该组件包可为在 Microsoft Windows Server 2016 下运行的 HPE Intel E1R 千兆以太网卡提供驱动程序。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1196584","datemodified":"2021-08-15T05:23:57","file_list":["cp047043.xml","cpqsetup.exe","cp_data.xml","e1r65x64.cat","e1r65x64.din","e1r65x64.inf","e1r65x64.sys","e1rmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"2300c3300a6f84dddb57fcbcfdb559f5","name":"cp047043.exe","release":"2021-08-15T05:09:28","revision":"0","sha1sum":"7dbfcf31abd104cda2581e04974b5f6cfdd091a2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac"],"type_of_change":"0","version":"12.16.4.1"}],"id":{"product":"fc4022f2727541aca9a0c50b935a3b24","version":"583c663084fc4dcd936fdb704cc8f37e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE Intel E1R 驅動程式（適用於 Windows Server 2016）"},{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel E1R 드라이버"},{"lang":"cn","x_late":"适用于 Windows Server 2016 的 HPE Intel E1R 驱动程序"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"e1r65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 7.0"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 7.0上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBandカードタイプ</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2ポート544+Mアダプター（764282-B21）</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+Mアダプター（764283-B21）</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+QSFPアダプター（764284-B21）</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2ポート544+FLR-QSFPアダプター（764285-B21）</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017 </td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2ポート544+FLR-QSFPアダプター（764286-B21）</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023 </td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20083186","datemodified":"2021-02-03T03:39:45","file_list":["/CP045904.vmexe64","/CP045904.vmfile","/CP045904_VMw.zip","/CP045904.xml","/payload.json","/README.txt","/CP045904_VMw.zip/index.xml","/CP045904_VMw.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip","/CP045904_VMw.zip/vib20/CP045904/HPE_bootbank_CP045904_1.0.0-7.0.0.15525992.vib","/CP045904_VMw.zip/metadata.zip/vendor-index.xml","/CP045904_VMw.zip/metadata.zip/vmware.xml","/CP045904_VMw.zip/metadata.zip/vibs/CP045904--1517099505877222018.xml","/CP045904_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045904_1.0.0-7.0.0.15525992.xml"],"md5sum":"e1a28cdfc099e4a1a327a84a68840576","name":"CP045904.zip","release":"2021-02-26T00:00:00","revision":"1","sha1sum":"ae97d7bab13cb5d0f10c76583ae32cdb3be0b6f7","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.1","vib_list":[{"name":"CP045904","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"b208c604a379445cb8f4da716ed6946e","version":"2bed7ba28d5f46339c9b9064a2b202d1"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 7.0"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 7.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-17T13:59:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11615200","datemodified":"2022-03-08T13:44:37","file_list":["cp051281.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_2.62_03_08_2022.signed.flash"],"md5sum":"567e40346cab4a6400802908d9b5d4c1","name":"cp051281.exe","release":"2022-03-08T13:43:25","revision":"0","sha1sum":"68e99ab806d2103efed2dcce764fc201c2408bb4","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"bf6c1988a6474823969dd84808070288","version":"06da43e3671f49889fe39acce40d7fb2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download cp047197.exe&nbsp;to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cp047197.exe.&nbsp;</p>\n\n<p>2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>&nbsp;</p>\n\n<p>Execute the file cp047197.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います。</strong><br />\n1.    cp047197.exeを、サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムにダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />\n2.    ファイル名を右クリックして、プロパティを選択します。<br />\n3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />\n4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />\n5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />\n6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />\n7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />\n        a.    ファームウェアを展開しないでください。<br />\n        b.    ファイルをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p>\n\n<p><br />\n<strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />\n1.    Microsoft Windows CRC/SHAツールを使用して、cp047197.exeのSHA256ハッシュ値を計算します。 </p>\n\n<p>2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />\n•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />\n•    値が一致しない場合は、ファイルやその内容を展開しないでください。<br />\n•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />\n•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p>\n\n<p> </p>\n\n<p>cp047197.exeファイルを実行し、画面の指示に従ってインストールを完了してください。<br />\nドライバーのインストールが完了した後、サーバーを再起動してください。</p>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:10:46","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5025946","datemodified":"2021-07-23T10:42:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/4IYRHPG6.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/CP048188.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG6-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048188.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048188.scexe"],"md5sum":"91b2a4db27604a6d4d9508a8cb440450","name":"firmware-hdd-c566d63ca0-HPG6-3.1.x86_64.rpm","release":"2021-07-23T10:30:07","revision":"0","sha1sum":"08d3a5f217584218c81d59204a7dfa80a86af041","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c6a4f7a1c0f14173802a4263b3ee7551","version":"92ac47bc180d45248ad5a01b57912e75"},"installation":{"command":"CP040783.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T08:13:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1230032","datemodified":"2021-01-14T07:44:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"41e355e8d3c84b3255ceef5737a6ffef","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"7fc9eff00e5853ddd7706d1f9bda348745a7bef5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1265721","datemodified":"2021-01-14T07:37:34","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi/component.xml"],"md5sum":"b3b83ef2621c73df7709acc7b11c91ad","name":"kmod-be2iscsi-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:31:04","revision":"0","sha1sum":"9400144fadc091f44fbc6b9e2738f3130fc5c6f4","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd9057dd3"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"da2886f50e85443fa3f87dcf733edc2b","version":"74cd88bdfbf54bf5bd8c1cc53129ec38"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6016440","datemodified":"2021-07-23T08:02:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/CP048134.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/HVLPeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048134.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048134.scexe"],"md5sum":"44528759ed2a0980b849016d45f36bde","name":"firmware-hdd-8b26d1ef02-HPD2-2.1.x86_64.rpm","release":"2021-07-23T07:50:08","revision":"0","sha1sum":"ddc7c8fb78a258a6ce934bd65346fbc85d56a2e4","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"596340d3247946aaa109faeb065a7eab","version":"8468aed0707544adbb9b82ce9c980bda"},"installation":{"command":"CP041479.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:48:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17484913","datemodified":"2021-08-27T04:18:11","file_list":["/CP048378_BUILD_2.data","/CP048378.vmexe","/CP048378.vmexe64","/CP048378.vmfile","/CP048378_VMw.zip","/CP048378.xml","/payload.json","/CP048378_VMw.zip/index.xml","/CP048378_VMw.zip/vendor-index.xml","/CP048378_VMw.zip/metadata.zip","/CP048378_VMw.zip/vib20/CP048378/HPE_bootbank_CP048378_HPDB.2-7.0.0.15843807.vib","/CP048378_VMw.zip/metadata.zip/vendor-index.xml","/CP048378_VMw.zip/metadata.zip/vmware.xml","/CP048378_VMw.zip/metadata.zip/vibs/CP048378-272077702656427524.xml","/CP048378_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048378_HPDB.2-7.0.0.15843807.xml"],"md5sum":"b3a831515a3f2a435ef897282b89f0df","name":"CP048378.zip","release":"2021-08-27T04:12:50","revision":"0","sha1sum":"e73b8757b6df813efd138240649b31edee22f486","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB","vib_list":[{"name":"CP048378","version":"HPDB.2-7.0.0.15843807"}]}],"id":{"product":"1d0e9b382f8640e89092917ac97996ce","version":"70460be367f946b3aa379f828104ac98"},"installation":{"command":"CP040519.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi  - MB6000JEQUV およびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:33:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5651665","datemodified":"2021-07-23T08:22:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/CP048083.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/SKESTND7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048083.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048083.scexe"],"md5sum":"ecfc62d6fab4113513207e568a756b2e","name":"firmware-hdd-3d97759111-HPD7-2.1.x86_64.rpm","release":"2021-07-23T08:08:07","revision":"0","sha1sum":"15acdad7bdb2ad51c91b4653a92a2f0f990938d3","size":"5MB","target_guids":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"eca7d77c8ba84ffe9014dfb5c3b6ee15","version":"78a7b4a2d74d4406a264b90ab1b79cbe"},"installation":{"command":"CP040309.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000300JWCPK、EH000600JWCPLおよびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:10:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4171776","datemodified":"2021-07-23T11:54:11","file_list":["cp048670.xml","cpqsetup.exe","HVLPeAsseFD2.rel","payload.json","setup.dll"],"md5sum":"68561745771c7137ac47211bd3e00524","name":"cp048670.exe","release":"2021-07-23T11:47:11","revision":"0","sha1sum":"a6dfebee149d0f256285fe1ea6b56072f6c1be2f","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"3f71b29f23c14fcb8f1f4cc9ac53400c","version":"503db59efcd746638f169d03cfc3bdb9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:21:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"サポートされているHPE Mellanoxアダプターカード用のHPE Mellanox MFTドライバーおよびFirmware Tool。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23543","datemodified":"2021-12-14T15:30:47","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/mst_pci.ko","./lib/modules/4.12.14-94.41-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"6cd7b08fffcc6523d91756af368732d8","name":"kernel-mft-mlnx-kmp-default-4.18.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-12-14T15:19:15","revision":"0","sha1sum":"742a3c9aa7346a99eed6e7ad9871e1974bb324c8","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"},{"bytes":"7970504","datemodified":"2021-12-14T15:33:45","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"6f3a193b041f556b8bf65534d60d7976","name":"mft-4.18.0-106.sles12sp4.x86_64.rpm","release":"2021-12-14T15:19:15","revision":"0","sha1sum":"cc7018e4e7f2acf3cc76ded408cef7149b7b9889","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"}],"id":{"product":"fb694776c4964491b586e98c556b93d2","version":"90bd31a6d72d4a2193bf076a3a07c7ff"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.18.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm&nbsp; mft-4.18.0-78.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4（AMD64/EM64T）向けのHPE Mellanox MFTドライバーおよびFirmware Tools"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"17070008","datemodified":"2021-08-26T19:38:32","file_list":["/CP048365_BUILD_2.data","/CP048365.vmexe","/CP048365.vmexe64","/CP048365.vmfile","/CP048365_VMw.zip","/CP048365.xml","/payload.json","/CP048365_VMw.zip/index.xml","/CP048365_VMw.zip/vendor-index.xml","/CP048365_VMw.zip/metadata.zip","/CP048365_VMw.zip/vib20/CP048365/HPE_bootbank_CP048365_HPG6.2-7.0.0.15843807.vib","/CP048365_VMw.zip/metadata.zip/vendor-index.xml","/CP048365_VMw.zip/metadata.zip/vmware.xml","/CP048365_VMw.zip/metadata.zip/vibs/CP048365--562824061359719919.xml","/CP048365_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048365_HPG6.2-7.0.0.15843807.xml"],"md5sum":"6fbb2b227af99c5099f48a91ca052914","name":"CP048365.zip","release":"2021-08-26T19:32:24","revision":"0","sha1sum":"8cafacc5773c5ffd9ec8303de1df6db9e2c4678c","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048365","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"27c04cd9178a40abb16f9409a4957000","version":"ee1feb31b6e0463ba7bdda80d0a17a6d"},"installation":{"command":"CP039421.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T18:32:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージには、SUSE Linux Enterprise Server 15上でEmulexホストバスアダプターおよびメザニンホストバスアダプターに対してHPE Storageファイバーチャネルアレイ接続を有効にするためのユーティリティとライブラリが含まれています。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1755262","datemodified":"2021-11-15T07:35:22","file_list":["./opt/emulex/sles15sp2/i386/lib/libdfc.so","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12","./opt/emulex/sles15sp2/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles15sp2/i386/lib/libemsdm.so","./opt/emulex/sles15sp2/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp2/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles15sp2/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp2/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"c404289e7b6ac7ab49cd71bf8cfbc2a0","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles15sp2.x86_64.rpm","release":"2021-11-15T07:29:25","revision":"0","sha1sum":"6aeda5624c40f5b9f3cff58dbbc4c2aefde53bb5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.526.0"},{"bytes":"1755243","datemodified":"2021-11-15T07:45:52","file_list":["./opt/emulex/sles15sp3/i386/lib/libdfc.so","./opt/emulex/sles15sp3/i386/lib/libdfc.so.12","./opt/emulex/sles15sp3/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles15sp3/i386/lib/libemsdm.so","./opt/emulex/sles15sp3/i386/lib/libemulexhbaapi.so","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so.12","./opt/emulex/sles15sp3/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles15sp3/x86_64/lib64/libemsdm.so","./opt/emulex/sles15sp3/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"666e2747035cdc12463dc96a297a2333","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles15sp3.x86_64.rpm","release":"2021-11-15T07:29:25","revision":"0","sha1sum":"93d38318f8418af799a9e60d4ff0eddea04f83cd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.526.0"}],"id":{"product":"3a4168637f45404b864aa9e998210305","version":"ced0d7f1666a438dae3b0872cc462fc3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>&nbsp;</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;2 and SuSE Linux Enterprise Server 15 service pack&nbsp;3 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --reinstall &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"},{"lang":"ja","x_late":"<p>イネーブルメントキットのインストール前にターゲット環境にlibHBAAPIパッケージをインストールしておく必要があります。（存在していない場合、libHBAAPIパッケージはオペレーティングシステムのインストールメディアから取得することができます。）</p>\n\n<p> </p>\n\n<p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>SuSE Linux Enterprise Server 15サービスパック2およびSuSE Linux Enterprise Server 15サービスパック3での同じイネーブルメントキットバージョンの書き換えは、--reinstallオプションを使用して実行する必要があります。</p>\n\n<p>例：rpm –Uvh HPE-CNA-FC-Emulex-Enablement-Kit-<version>.<OS>.<architecture>.rpm --reinstall              </p>\n\n<p> 詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulexファイバーチャネルイネーブルメントキットforホストバスアダプターおよびメザニンホストバスアダプター - SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for SLES 15 SP3</li>\n</ul>\n\n<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"},{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"5545829","datemodified":"2021-07-23T08:29:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/CP048079.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/HCFL4CD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a2c06af48-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048079.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048079.scexe"],"md5sum":"2957ed781570c986a3acbfeb59465af2","name":"firmware-hdd-8a2c06af48-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:16:09","revision":"0","sha1sum":"4c4ff7c197bf126b826a4e2515331c3118f188a3","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"121d8116603e47a49293c085684f3fa1","version":"5c2157b1aea54b978fadca9a88c38935"},"installation":{"command":"CP040315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:57:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and&nbsp;MK003840GWTTN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16515980","datemodified":"2021-08-27T10:18:11","file_list":["/CP048408_BUILD_3.data","/CP048408.vmexe","/CP048408.vmexe64","/CP048408.vmfile","/CP048408_VMw.zip","/CP048408.xml","/payload.json","/CP048408_VMw.zip/index.xml","/CP048408_VMw.zip/vendor-index.xml","/CP048408_VMw.zip/metadata.zip","/CP048408_VMw.zip/vib20/CP048408/HPE_bootbank_CP048408_HPG6.3-7.0.0.15843807.vib","/CP048408_VMw.zip/metadata.zip/vendor-index.xml","/CP048408_VMw.zip/metadata.zip/vmware.xml","/CP048408_VMw.zip/metadata.zip/vibs/CP048408--799434529393724594.xml","/CP048408_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048408_HPG6.3-7.0.0.15843807.xml"],"md5sum":"8a9579504cd0880002d7f7128042891a","name":"CP048408.zip","release":"2021-08-27T10:12:48","revision":"0","sha1sum":"467805714e5410d2eebce66df6eef85255f362a9","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048408","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"c5274a8d3e3e40d790c226da85bd84aa","version":"526c2f35074e4106bc2436ed31826a65"},"installation":{"command":"CP040790.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T04:55:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for ESXi 7.0 U1.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7970506","datemodified":"2021-12-14T15:38:43","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"4b303aa41920d08590e08377d32bcd52","name":"mft-4.18.0-106.sles12sp5.x86_64.rpm","release":"2021-12-14T15:29:05","revision":"0","sha1sum":"5491e148be5d04b04a397376a6af80d2f9a90d2c","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.18"},{"bytes":"21779","datemodified":"2021-12-14T15:37:23","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/mst_pci.ko","./lib/modules/4.12.14-120-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"5266fd9f6a093a4b67cc1e2491c3dda8","name":"kernel-mft-mlnx-kmp-default-4.18.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-12-14T15:29:05","revision":"0","sha1sum":"7b606fbaf9f48d90c306fdfa22eebae9e582fd85","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.18"}],"id":{"product":"121737c377d94d3aa35bfe198f1f6e1f","version":"2ed7c08a122643d99d98fae57edadb6e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.18.0_k4.12.14_120-1.sles12sp5.x86_64.rpm&nbsp; mft-4.18.0-78.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL, and EH000900JWCPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3781072","datemodified":"2021-07-24T05:56:12","file_list":["cp048510.xml","cpqsetup.exe","payload.json","setup.dll","SKESTND7.rel"],"md5sum":"68075c607b1fe59bf334047b6c57eedd","name":"cp048510.exe","release":"2021-07-24T05:48:08","revision":"0","sha1sum":"4d74837c7d11a145e39235d2e7ac07aaf6e55dcf","size":"3MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"3f2f70c223354bc6b59b77123faa8545","version":"ecb71206461a484da2e8a4cbd61d5859"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:41:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4754432","datemodified":"2021-07-25T12:43:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/CP045366.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9a826ccd8a-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045366.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045366.scexe"],"md5sum":"fa10fe81bcfafe6eaeaa0efbc8474faf","name":"firmware-hdd-9a826ccd8a-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:31:04","revision":"0","sha1sum":"a60d89aa6a9d31262c72ba200403cc9e2b6277ab","size":"4MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"a35c5c84e8e149fe9fff61ed94a4a7ac","version":"985eead36b2143309c7841486491583a"},"installation":{"command":"CP040088.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:13:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2126442","datemodified":"2021-02-25T07:55:23","file_list":["/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip","/cp044633.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/vendor-index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/vib20/vmware-storcli64/BCM_bootbank_vmware-storcli64_007.1616.0000.0000-01.vib","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vendor-index.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vmware.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/vibs/vmware-storcli64-471654706444394320.xml","/BCM-vmware-storcli64_007.1616.0000.0000-01_17650073.zip/metadata.zip/bulletins/BCM-vmware-storcli64_007.1616.0000.0000-01.xml"],"md5sum":"833553f49b2b206dcb914ea05217da9c","name":"cp044633.zip","release":"2021-02-25T07:54:04","revision":"0","sha1sum":"19d5b3e94f8e601b2ffc55d55c6cef65f13dca63","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f161a38","20a6e8e4-bf33-4c71-a6bf-d9ec466b4ce5"],"type_of_change":"1","version":"2021.04.00","vib_list":[{"name":"vmware-storcli64","version":"007.1616.0000.0000-01"}]}],"id":{"product":"227d96d8e01b420b8686e88babe12d3a","version":"45cf739dde494438b0242c6056f54af4"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 7.0 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -d=&lt;path&gt;&lt;componet_bundle&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-22T13:17:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Supported on ESXi OS 7.0 64 bit</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"BCM-vmware-storcli64:007.1616.0000.0000-01","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"vmware-storcli64:007.1616.0000.0000-01","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.3089.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7 and 7.0"},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7,0で動作するHPE ProLiant Intel Gigabit Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25469707","datemodified":"2021-11-02T16:04:18","file_list":["/CP049895_BUILD_7.data","/CP049895.vmexe","/CP049895.vmexe64","/CP049895.vmfile","/CP049895_VMw.zip","/CP049895.xml","/payload.json","/CP049895_VMw.zip/index.xml","/CP049895_VMw.zip/vendor-index.xml","/CP049895_VMw.zip/metadata.zip","/CP049895_VMw.zip/vib20/CP049895/HPE_bootbank_CP049895_3.15.50.7-7.0.0.15843807.vib","/CP049895_VMw.zip/metadata.zip/vendor-index.xml","/CP049895_VMw.zip/metadata.zip/vmware.xml","/CP049895_VMw.zip/metadata.zip/vibs/CP049895--6534084502673984895.xml","/CP049895_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049895_3.15.50.7-7.0.0.15843807.xml"],"md5sum":"289a394e973d44928d406a0319930e28","name":"CP049895.zip","release":"2021-11-02T15:59:12","revision":"0","sha1sum":"e4c829f0caa924d49f296700fbe781af21b91268","size":"24MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"1","version":"3.15.50","vib_list":[{"name":"CP049895","version":"3.15.50.7-7.0.0.15843807"}]}],"id":{"product":"79ba405b8c19425aa9a14902b672b652","version":"8f555572d0ce4e24888ddd902854c7af"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong><em>Additional Information:</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<li>VMwareコンポーネントをインストールします。\n\t<ul>\n\t\t<li>a. ESXi 7.0ターゲットの場合：esxcli software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<li>b. ESXi 6.xターゲットの場合：esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ul>\n\t</li>\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ul>\n\t\t<li>a. /opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<li>b. Smartコンポーネントをクリーンアップするには：\n\t\t<ul>\n\t\t\t<li>i. ESXi 7.0ターゲットの場合：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii. ESXi 6.xターゲットの場合：esxcli software vib remove –n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c. CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong><em>追加情報：</em></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、次のカスタマーアドバイザリを参照してください。 <br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後に電源を再投入する必要があります。<br />\n\tHPE Ethernet 1Gb 2ポート368iアダプター<br />\n\tHPE Ethernet 1Gb 2ポート369iアダプター<br />\n\tHPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />\n\tHPE Ethernet 10Gb 2ポート 568FLR-MMSFP+アダプター<br />\n\tHPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Intel 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Intel在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-01T07:02:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 u3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.11.0.</p>\n"}],"files":[{"bytes":"199847","datemodified":"2021-11-19T09:56:10","file_list":["/cp049117.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/index.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/metadata.zip","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/vib20/ixgben/INT_bootbank_ixgben_1.10.3.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-ixgben-1.10.3.0.xml","/VMW-ESX-6.5.0-ixgben-1.10.3.0-offline_bundle-18150350.zip/metadata.zip/vibs/ixgben--5841797763395565623.xml"],"md5sum":"92375fa4101704fc6c7e5465f3983e7a","name":"cp049117.zip","release":"2021-11-19T09:51:55","revision":"0","sha1sum":"6b7ed37b49006d2aadd4f92462a11cb2317cf9c6","size":"195KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.12.00","vib_list":[{"name":"ixgben","version":"1.10.3.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"a6351a56dbe64b13b1076909ea7de13e","version":"f06a39d0747f40ffa6b88382aa970243"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T08:38:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where non-working MAC anti-spoofing</li>\n\t<li>This product corrects an issue where incorrect values in virtual function counters</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.10.3.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4855824","datemodified":"2021-12-07T04:54:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/CP050183.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/TA15SEn0HPD5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050183.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050183.scexe"],"md5sum":"2af65b2cf1e4699288651430371af21e","name":"firmware-hdd-24fe569b72-HPD5-1.1.x86_64.rpm","release":"2021-12-07T04:40:25","revision":"0","sha1sum":"3413163298fe051ecd7c73d103d4744d6640f246","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"779f4f17fec64b6b9acf9ede668fc68a","version":"a1efe8895a804de3bcfc12d202cf428f"},"installation":{"command":"CP041564.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP.<nnnnnn>scexeスクリプトは、'scexe-compat'フォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:36:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000GWWQUおよびMB006000GWWQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3767336","datemodified":"2021-07-25T20:03:35","file_list":["cp048648.xml","cpqsetup.exe","payload.json","SCIMARRNETG2.rel","setup.dll"],"md5sum":"4402bdc8bed15aca99f9a5ce74afe989","name":"cp048648.exe","release":"2021-07-25T19:56:04","revision":"0","sha1sum":"af22f00734f36fa5988cc5a285c9e2570788f663","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"c65e02b4990e43eea4fa2402b45960eb","version":"fb60773c9c834ebc8a6d9dda216daed4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:27:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; GPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18438442","datemodified":"2021-08-30T06:40:45","file_list":["/CP049279_BUILD_1.data","/CP049279.vmexe","/CP049279.vmexe64","/CP049279.vmfile","/CP049279_VMw.zip","/CP049279.xml","/payload.json","/CP049279_VMw.zip/index.xml","/CP049279_VMw.zip/vendor-index.xml","/CP049279_VMw.zip/metadata.zip","/CP049279_VMw.zip/vib20/CP049279/HPE_bootbank_CP049279_GPK3.1-7.0.0.15843807.vib","/CP049279_VMw.zip/metadata.zip/vendor-index.xml","/CP049279_VMw.zip/metadata.zip/vmware.xml","/CP049279_VMw.zip/metadata.zip/vibs/CP049279-667443216068728449.xml","/CP049279_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049279_GPK3.1-7.0.0.15843807.xml"],"md5sum":"2190c4b78c7dedc1579b34e93c46eb1a","name":"CP049279.zip","release":"2021-08-30T06:35:46","revision":"0","sha1sum":"4a07b63d02b7da750ed7417623bf225778f631d9","size":"17MB","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK3","vib_list":[{"name":"CP049279","version":"GPK3.1-7.0.0.15843807"}]}],"id":{"product":"92d52e2161c24f8f9ff633da842f814c","version":"e877e5f61b494a18b3c6bd3ebc25bbf4"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:21:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"336173","datemodified":"2021-10-01T18:41:19","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"9d8ad1f601cbadddae64c7bd0257bf8d","name":"kmod-bnxt_en-1.10.2-219.0.55.0.rhel7u9.x86_64.rpm","release":"2021-10-01T18:26:04","revision":"0","sha1sum":"593acee369c5dcbf9cc59d54a60d01d8cdf75dff","size":"328KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-219.0.55.0"},{"bytes":"336156","datemodified":"2021-10-01T18:40:10","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"ea5c62d26f680e1e6ba8a87348f7c69f","name":"kmod-bnxt_en-1.10.2-219.0.55.0.rhel7u8.x86_64.rpm","release":"2021-10-01T18:26:04","revision":"0","sha1sum":"d2c67dab2fdc22b7a82a0509366d8fe362511497","size":"328KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-219.0.55.0"}],"id":{"product":"8f50751a2a4c4c6eac4753b883c9d78b","version":"f3c8a5bd972247b4b0702a694ddad08c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n\t<li>This product addresses an issue where Virtual Functions (VFs) cannot be configured while the Physical Function (PF) interface is administratively down.</li>\n\t<li>This product addresses an issue where system crash when driver unloads while firmware reset is in progress.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE and VO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for Windows (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2881312","datemodified":"2021-08-31T14:06:00","file_list":["cp049412.xml","cpqsetup.exe","payload.json","setup.dll","TAPM2RD4.rel"],"md5sum":"ed0ffd21acd9adbde7b0fcc93110a404","name":"cp049412.exe","release":"2021-08-31T13:58:16","revision":"0","sha1sum":"207698f78d5128bd8fb680995bb0a56628601af3","size":"2MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4"}],"id":{"product":"d2a88686878e43e6b0ba883edf80c3c8","version":"694f1729bd1942ac8e61deb281cf4b99"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VK0400JEABD、VK0800JEABE、およびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:35:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6931298","datemodified":"2021-11-18T07:08:02","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"b6fde59a95bd9fe8baf970610dc40b34","name":"kmod-netxtreme2-7.15.02-1.rhel7u9.x86_64.rpm","release":"2021-11-18T06:41:56","revision":"0","sha1sum":"fb42df397f93365abdf1ecdfd6dbca3e4d179a84","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.02-1"},{"bytes":"6929774","datemodified":"2021-11-18T07:04:58","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"fbe619eb9af18c7b8a5d26cbe0f62ec5","name":"kmod-netxtreme2-7.15.02-1.rhel7u8.x86_64.rpm","release":"2021-11-18T06:41:56","revision":"0","sha1sum":"fcd542c0e2c6eb9f34e1caaada97afc215e4c20f","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.02-1"}],"id":{"product":"fd1884928c824890aec3a37db50b22e0","version":"95d94479f1bc4b43ae4a6b18e0988b87"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、ESXi 6.5上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28741560","datemodified":"2022-02-08T09:50:47","file_list":["/CP050368.vmexe","/CP050368.vmfile","/CP050368.xml","/CP050368_VMw.zip","/payload.json","/README.txt","/CP050368_VMw.zip/index.xml","/CP050368_VMw.zip/vendor-index.xml","/CP050368_VMw.zip/metadata.zip","/CP050368_VMw.zip/vib20/CP050368/HPE_bootbank_CP050368_1.0.4-6.5.0.4240417.vib","/CP050368_VMw.zip/metadata.zip/vendor-index.xml","/CP050368_VMw.zip/metadata.zip/vmware.xml","/CP050368_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050368_1.0.4-6.5.0.4240417.xml","/CP050368_VMw.zip/metadata.zip/vibs/CP050368-3431376411192976465.xml"],"md5sum":"127f900671a7eca0ba39b20a1b2467ed","name":"CP050368.zip","release":"2022-02-08T10:16:06","revision":"0","sha1sum":"c6d4554cb6b2fee2ffde0eadc535efa45876f6c3","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.11","vib_list":[{"name":"CP050368","version":"1.0.4-6.5.0.4240417"}]}],"id":{"product":"80d81c90aa4043f99c110cbf04419c83","version":"ee27e65bdc3844eebe1538ee38cae0c8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 6.5)"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T11:02:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)</li>\n\t<li>779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li>\n\t<li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following device has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogicメザニンファイバーチャネルドライバー"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1540313","datemodified":"2021-08-27T03:59:42","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp046773.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"8561e82564d6275b0231560d37b241c3","name":"cp046773.zip","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"6f200399ae4705244b34a2fa38d71d74b775306d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"74bcebdbd1974e4b8af3429e65c84801","version":"f41ee113735542bda899b2b049913902"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogicメザニンファイバーチャネルドライバーコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-26T05:45:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"219.0.144.0"},{"DeviceName":"Broadcom NetXtreme-E BCM5741x adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm219.0.144.0.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"219.0.144.0"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E BCM5741x Gigabit Ethernet NIC firmware."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 219.0.144.0a with the following firmware versions:</p>\n\n<ul>\n\t<li>Bootcode Version: 219.0.112.0</li>\n\t<li>NCSI Version: 219.0.83.0</li>\n\t<li>MBA Version:&nbsp;219.0.13.0</li>\n\t<li>UEFI Version:&nbsp;219.0.38.0</li>\n\t<li>CCM Version:&nbsp;219.0.6.0</li>\n\t<li>RoCE Version:&nbsp;219.0.2.0</li>\n</ul>\n"}],"files":[{"bytes":"7428345","datemodified":"2021-09-27T10:56:22","file_list":["bcm219.0.144.0.pup.HPb","bcm219.0.144.0.pup.xml","payload.json"],"md5sum":"203682c1544edfcb23098a4c43dcea78","name":"bcm219.0.144.0.pup.fwpkg","release":"2021-09-27T10:52:25","revision":"0","sha1sum":"e19c473c2bdc66d6ea766896f0332794dc4b5535","size":"7MB","target_guids":["a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16d614e41595"],"type_of_change":"1","version":"219.0.144.0"}],"id":{"product":"5fcadb289d2a4581aa347222e1e2d7d1","version":"91bef687f7694f3aa51a5e6277104d89"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom Firmware Package for BCM5741x adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41596","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where unexpected firmware update failure due to NVM fragementation.</li>\n\t<li>This product corrects an issue where the SSID of ​Broadcom BCM57416 Ethernet 10Gb 2-port BASE-T OCP3 Adapter</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"BCM_NXE_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6301248","datemodified":"2021-07-23T09:26:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/CP048206.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/GSM883G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f693ccc138-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048206.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048206.scexe"],"md5sum":"8a6bc85e8e4629745d32e114ee7f4a03","name":"firmware-hdd-f693ccc138-HPG3-3.1.x86_64.rpm","release":"2021-07-23T09:14:09","revision":"0","sha1sum":"3cebc2b0fc6d20c9f3219f8f4a2af2b13820d181","size":"6MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"17be7af3223241a4bef4e8f0da8afac5","version":"f0e040155968423da194497600d2ffc0"},"installation":{"command":"CP041676.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします: </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- MK000480GWSSC、 MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:33:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4302688","datemodified":"2021-09-02T09:02:15","file_list":["./etc/depmod.d/brcmfcoe.conf","./etc/dracut.conf.d/brcmfcoe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe","./lib/modules/4.18.0-240.el8.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"82f2a72f49fe29ddd296456797c5c462","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-09-02T08:54:11","revision":"0","sha1sum":"0e6591455b5d22d73cb1156089387d8299a6dfed","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"de4e8e44a39b461c93ece5604d26abfa","version":"efc2247b96774beb8fda940702a9c0c1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-rhel8u3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 3 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:12:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n\n<p>Updated to Driver version 12.0.1342.0</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where cluster nodes could be evicted during Fibre Channel over Ethernet (FCoE) multipath failover as described in <a href=\"https://access.redhat.com/solutions/3136041\">https://access.redhat.com/solutions/3136041</a></li>\n\t<li>Fixed a behavior where Ethernet connections may not recover after a Virtual Connect (VC) interconnect module reboot</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3322632","datemodified":"2021-07-25T20:41:07","file_list":["cp048651.xml","cpqsetup.exe","payload.json","PLTGIID7.rel","setup.dll"],"md5sum":"46c7e835dcfc9acae52a3b2c6a3f6dcd","name":"cp048651.exe","release":"2021-07-25T20:34:11","revision":"0","sha1sum":"f0c618429a31b9a658599770aaab8ea710b1df38","size":"3MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"a5c4c8dc7b4a47d3abf311a168b0a29d","version":"cdbbc8bf0dee4dba9d7ac57a6abf71f1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:49:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1063048","datemodified":"2021-11-09T06:36:09","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"87bf2598fd5239372f5528d1ae8970d6","name":"hp-ixgbevf-kmp-default-4.13.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-11-09T06:25:15","revision":"0","sha1sum":"2a68a81095d6927df1ca90981c376626166b23d7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.13.3-1"}],"id":{"product":"cff92813aa394a808304dff72295152b","version":"0b79b7a503e94ade940df48d25d526c2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where potential memory leak</li>\n\t<li>This product addresses an issue where eXpress Data Path(XDP) frame size calculations.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB8000GFECR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3532824","datemodified":"2021-07-25T16:10:18","file_list":["cp048618.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPTG6.rel"],"md5sum":"8df68ace593e8dffb988ad283cd9ac02","name":"cp048618.exe","release":"2021-07-25T16:03:04","revision":"0","sha1sum":"cd843488484b5555d6645151ab15b3fff3119fcb","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"82d1b2ac21094989a9b2118ea6829df2","version":"ab89b8e954b34458b8eabf3717871671"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:25:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JWXKH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5563143","datemodified":"2021-07-26T15:57:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/CP049125.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/TAMG08scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049125.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049125.scexe"],"md5sum":"0f3407ec9e7147e68f636e107df84d7b","name":"firmware-hdd-8a0371a425-HPD9-2.1.x86_64.rpm","release":"2021-07-26T15:44:07","revision":"0","sha1sum":"0fc910989da04f75be3a1bb17f317433e9ea3d3e","size":"5MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"aa62b707fef04bb99492053e558daffb","version":"471351bfe45d463b98131b92e91c96cc"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:39:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB001000GWJAN、MB002000GWFWA および MB004000GWFWB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3396800","datemodified":"2021-07-23T19:23:00","file_list":["cp048558.xml","cpqsetup.exe","payload.json","setup.dll","TATCATSATAG1.REL"],"md5sum":"b288ba95315cda1d1a1646d432e9f187","name":"cp048558.exe","release":"2021-07-23T19:15:04","revision":"0","sha1sum":"d8d583957a7881c2930d1da1d16d2568469ed4bf","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3d1400a6e0204fb498134f7e6e3f374a","version":"59d5ad6748fe48afb3192b88770d4f8b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:50:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for&nbsp;Linux&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&bull;&nbsp;&nbsp; Added support for RHEL 8.4 and SLES15SP3.</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None&nbsp;&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4664174","datemodified":"2021-07-23T08:47:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/CP048186.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/GP863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f42438de3d-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048186.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048186.scexe"],"md5sum":"c158ca816de427a3b551394e0a7b2dd0","name":"firmware-hdd-f42438de3d-HPG3-7.1.x86_64.rpm","release":"2021-07-23T08:34:09","revision":"0","sha1sum":"382cd2dcb8cbd108513ee4d3adc732737ae6f68b","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"dee0352e8d5a4157b5757fd1a1669bb8","version":"973868c2b7354caea45f113c8509c4a0"},"installation":{"command":"CP040346.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:57:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 6.5. "},{"lang":"ja","x_late":"このパッケージには、ESXi 6.5上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15949677","datemodified":"2022-02-08T10:27:45","file_list":["/CP050391.vmexe","/CP050391.vmfile","/CP050391.xml","/CP050391_VMw.zip","/payload.json","/README.txt","/CP050391_VMw.zip/index.xml","/CP050391_VMw.zip/vendor-index.xml","/CP050391_VMw.zip/metadata.zip","/CP050391_VMw.zip/vib20/CP050391/HPE_bootbank_CP050391_1.0.4-6.5.0.4240417.vib","/CP050391_VMw.zip/metadata.zip/vendor-index.xml","/CP050391_VMw.zip/metadata.zip/vmware.xml","/CP050391_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050391_1.0.4-6.5.0.4240417.xml","/CP050391_VMw.zip/metadata.zip/vibs/CP050391-2123589278251262189.xml"],"md5sum":"66ee2f811309cd04b7a3130a9f748d12","name":"CP050391.zip","release":"2022-02-08T10:31:12","revision":"0","sha1sum":"5198ec7ea9c06f221969498d02aaeeb1cd828c78","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP050391","version":"1.0.4-6.5.0.4240417"}]}],"id":{"product":"d4fc4da3121749de965df405cffc318e","version":"aa00a9202d1b4981a7daa3d7f8016452"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 6.5）"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T08:50:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.31.1014:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027405","datemodified":"2021-03-08T18:25:46","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"9b19062e20d318dc6d2be41b872182be","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"69e8751f557da72218c9b58062d693d082422476","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1055055","datemodified":"2021-03-08T18:21:31","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf","./lib/modules/4.12.14-120-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"d4788382bd188db5898b7abb8b5f0bfb","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:13:11","revision":"0","sha1sum":"2d3b57753612f3f550c0a667f58118c5c5cc5ab8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"88b0a89daaf348e9967e08f08cad5650","version":"7e3f1a803b874274afd2472a9cd4d129"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4095480","datemodified":"2021-12-20T08:57:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/CP050141.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050141.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050141.scexe"],"md5sum":"717b3a04551ac1e514697b58bd95e593","name":"firmware-d6020-2.74-11.1.x86_64.rpm","release":"2021-12-20T08:49:05","revision":"0","sha1sum":"2419ee91ef0beb991b430ba4ae727cf5fe6e26ed","size":"3MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"id":{"product":"ce7e63b5ed004965a0bc6af06ca584ef","version":"55184e172c5141058e2cdd2beb07a88a"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;</em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d6020-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d6020-&lt;version&gt;-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d,&nbsp;--discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e,&nbsp;--reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f,&nbsp; --force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g,&nbsp;--downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s,&nbsp;--silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created&nbsp; Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-29T12:31:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color:blue; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16682127","datemodified":"2021-08-27T08:58:27","file_list":["/CP048511_BUILD_2.data","/CP048511.vmexe","/CP048511.vmexe64","/CP048511.vmfile","/CP048511_VMw.zip","/CP048511.xml","/payload.json","/CP048511_VMw.zip/index.xml","/CP048511_VMw.zip/vendor-index.xml","/CP048511_VMw.zip/metadata.zip","/CP048511_VMw.zip/vib20/CP048511/HPE_bootbank_CP048511_4ICRHPK3.2-7.0.0.15843807.vib","/CP048511_VMw.zip/metadata.zip/vendor-index.xml","/CP048511_VMw.zip/metadata.zip/vmware.xml","/CP048511_VMw.zip/metadata.zip/vibs/CP048511-6164370636035978595.xml","/CP048511_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048511_4ICRHPK3.2-7.0.0.15843807.xml"],"md5sum":"d320362140829da7a4d3689651ea81e5","name":"CP048511.zip","release":"2021-08-27T08:53:27","revision":"0","sha1sum":"d3efbe7088543cd73451afc93967097317cad7ce","size":"15MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3","vib_list":[{"name":"CP048511","version":"4ICRHPK3.2-7.0.0.15843807"}]}],"id":{"product":"a5e366733eda432d8665f3d8aaa40d56","version":"68760c8a1e514d1c8c960ebadb663b56"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:11:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed issues described in Customer Bulletin at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color:blue; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1852408","datemodified":"2021-08-24T15:35:14","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-iavf","./lib/modules/5.3.18-57-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"20af4a75ade72de26f2483f2893d3fa2","name":"hp-iavf-kmp-default-4.2.7_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-08-24T15:23:06","revision":"0","sha1sum":"72e2f87156adb84f2843050609ee19d88ffec5e1","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"1804068","datemodified":"2021-08-24T15:32:23","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-iavf","./lib/modules/5.3.18-22-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"87be7480268b443c680090af6642a420","name":"hp-iavf-kmp-default-4.2.7_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-24T15:23:06","revision":"0","sha1sum":"82eb249166630a6c6e15d9fdeaf1793889848012","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"5156ee2ce74d4685bd9c2931c6170220","version":"2f72a814d8fe4de18ea699ae3617b9e2"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.55.14"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_ah_mbi_open_8.55.14_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.14"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v8.55.14.&nbsp;This combo image includes: PXE:2.0.19, Boot Code (MFW): 8.55.43.0, and UEFI: 6.1.8.2.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージには、コンボイメージv8.55.14が含まれています。 このコンボイメージには以下が含まれます。PXE：2.0.19、ブートコード（MFW）：8.55.43.0、UEFI：6.1.8.2。</p>\n"}],"files":[{"bytes":"1951757","datemodified":"2021-08-12T11:48:22","file_list":["payload.json","ql_ah_mbi_open_8.55.14_pldm.HPb","ql_ah_mbi_open_8.55.14_pldm.xml"],"md5sum":"32efc0a1491d0f13a32179e8bddf9c0a","name":"ql_ah_mbi_open_8.55.14_pldm.fwpkg","release":"2021-09-16T00:00:00","revision":"1","sha1sum":"a5a7bb2d5f2fba0cacfc61ce76489648fbb96f71","size":"1MB","target_guids":["a6b1a447-382a-5a4f-1077-80f010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-807010770068"],"type_of_change":"1","version":"8.55.14"}],"id":{"product":"5c10ef42611f4cada08e038ec64fbce6","version":"4c2bc81de05647068511527eab94b362"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n\t<li>\n\t<p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n\t<li>\n\t<p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Marvell FastLinQ Firmware Package for Arrowhead adapters"},{"lang":"ja","x_late":"Arrowheadアダプター用Marvell FastLinQファームウェアパッケージ"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T08:47:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n"},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"<p>This product contains support PLDM firmware upgrade base improvements.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"MARVELL_FLQ_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000GWWQUおよびMB006000GWWQTドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5609760","datemodified":"2021-07-23T09:15:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/CP048199.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/SCIMARRNETG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048199.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048199.scexe"],"md5sum":"02495a23949ae1cf89c4679a913c7174","name":"firmware-hdd-18e328f036-HPG2-4.1.x86_64.rpm","release":"2021-07-23T09:02:11","revision":"0","sha1sum":"62b382f396ce9d160d20f5e97c264404d6bdd6e1","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"862d36dd920c478ca6dcfdb5f392893a","version":"1add6f474af546e091f7460aa488c903"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:06:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM2ストレージバックプレーンをアップデートします。\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3934483","datemodified":"2022-02-23T05:54:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/CP051210.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/UBM2_V1.20.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-1.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051210.scexe"],"md5sum":"37879d5e1d51fe80ef7f4bbead214ad7","name":"firmware-smartarray-40023de47f-1.20-1.1.x86_64.rpm","release":"2022-02-23T05:37:50","revision":"0","sha1sum":"225d82ad9e9939c3eea11ca0e4a62c7713f1d498","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.20"}],"id":{"product":"baaff1c67f3f496a9b2cb59a73843db0","version":"01875550b0fb47b3885278684247bd6d"},"installation":{"command":"CP050746.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP042957.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-40023de47f-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP042957.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-smartarray-40023de47f-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート：</strong></em></p>\n\n<ul>\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/x86_64-linux-gnu'の場所へrpmの内容を解凍します。</li>\n\t<li>CP042957.scexeスクリプトは'hp-scexe-compat'フォルダーにあります。'firmware-smartarray-40023de47f-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：</li>\n</ul>\n\n<p>               # ./ CP042957.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</p>\n\n<p>     # ./setup（'/usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*'で実行）</p>\n\n<ul>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは'.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id  これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-40023de47f-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-smartarray-40023de47f-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記に概説した手順に従う必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Linux - Gen10Plus UBM2バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-22T14:10:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 8 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラーを有効にする、64ビットRed Hat Enterprise Linux 8用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"976942","datemodified":"2022-01-19T12:48:08","file_list":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/megaraid_sas","./lib/modules/4.18.0-305.el8.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"8f6d6e4190f05af50b06a559a172362c","name":"kmod-megaraid_sas-07.719.04.00_el8.4-1.x86_64.rpm","release":"2022-01-19T12:46:22","revision":"0","sha1sum":"e70aa6f97a726f94b243581cfdadd0ae8d26b406","size":"954KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.719.04.00"}],"id":{"product":"d8869737bfef407fbb159aff392990e1","version":"1cda5db7e9c3416ca82185e3850a4d38"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel8uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラードライバーfor 64-bit Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-11T07:25:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Support RHEL8.4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1412188","datemodified":"2021-12-13T23:20:46","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/.build-id","./usr/lib/.build-id/38","./usr/lib/.build-id/38/8bc6b87ce9e4a01988fdabbf1cef49259c3d22","./usr/lib/.build-id/50","./usr/lib/.build-id/50/5ff45876686ace4f75addf3497e63fa62c97ff","./usr/lib/.build-id/53","./usr/lib/.build-id/53/9a03776f91a92bbb6f595a0ddb5ebc74cf7ea9","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/236c51f8ce37b2f2230c0ab3fd0e244368e949","./usr/lib/.build-id/a6","./usr/lib/.build-id/a6/cead5459b37aee0d00ad90e25875d39f12e726","./usr/lib/.build-id/ae","./usr/lib/.build-id/ae/e5967b2f0856da6cac10c24096c3a23368ec00","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/75da2878f492d5f281c8184a28e1eab972e7bb","./usr/lib/.build-id/c7","./usr/lib/.build-id/c7/075c36777bbcd9d5b36834ef551a944dd239fd","./usr/lib/.build-id/d3","./usr/lib/.build-id/d3/ce7ca6a5b1ed8f62008cfde6dd7ebd521d75b8","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/d59484b6067fb542cac4676acd6bfd234f8489","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp","./usr/share/doc/dpcp/README","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/COPYING.BSD_FB","./usr/share/doc/rdma-core/COPYING.BSD_MIT","./usr/share/doc/rdma-core/COPYING.GPL2","./usr/share/doc/rdma-core/COPYING.md","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"b3e80807c5fae734812c7d044f7fcdd8","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel8u5.x86_64.rpm","release":"2021-12-13T22:13:15","revision":"0","sha1sum":"d1f82acc17f84f47f12faefcb576b4817cedee4b","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.5"},{"bytes":"1735836","datemodified":"2021-12-13T23:23:47","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"acba4c49b62ac80c6f5cf034c857f496","name":"kmod-mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel8u5.x86_64.rpm","release":"2021-12-13T22:13:15","revision":"0","sha1sum":"7068e34375ca6fc78910558b1d583890f4eabaf3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"5.5"}],"id":{"product":"efd223e91b2b47c1a6686d2ee30f32f7","version":"3da59be020e24d84a1258878d251649b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.rhel8u4.x86_64.rpm mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 8 Update 5 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:21:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1025504","datemodified":"2020-12-02T17:25:23","file_list":["cp045179.xml","cpqsetup.exe","cp_data.xml","install.xml","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"96cfa4d8770ef91ae69e90892a2b3574","name":"cp045179.exe","release":"2020-12-02T17:11:09","revision":"0","sha1sum":"78ac09b544a2e68ea4476101a12c6c67a2bf7a2d","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.192.0"}],"id":{"product":"f5e3995830b040538ed866e14afc4c24","version":"fa6e7ba979934b8cabc2bc12f19a5fa1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, vxnmsg.dll, nicco5.dll, and nicinvxn.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM4_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM4ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3950920","datemodified":"2022-01-17T14:20:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/CP050756.xml","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/UBM4_V1.24.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-8586fe2547-1.24-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050756.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050756.scexe"],"md5sum":"329d81f60f55b0d43a7f94acc3279be7","name":"firmware-8586fe2547-1.24-1.1.x86_64.rpm","release":"2022-01-17T14:02:50","revision":"0","sha1sum":"4f3ee1b1a11520e6588622292711a600c825c5c2","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.24"}],"id":{"product":"a6b537d158284bcb8d8b5bf0c949d656","version":"a1841d457aa84f5ab76bd03b412b5322"},"installation":{"command":"CP050756.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP049068.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-8586fe2547-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP049068.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-8586fe2547-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-8586fe2547-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-8586fe2547-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート：</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/x86_64-linux-gnu'の場所へrpmの内容を解凍します。</li>\n\t<li>CP049068.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-8586fe2547-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：</li>\n</ul>\n\n<p>               # ./ CP049068.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'内）（または）</p>\n\n<p style=\"margin-left:40px\">     # ./setup（'/usr/lib/x86_64-linux-gnu/firmware-8586fe2547-*'で実行）</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは'.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id  これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-8586fe2547-*'に移動し、./setupを実行してファームウェアをアップデートします。'firmware-8586fe2547-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記に概説した手順に従う必要があります。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM4 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Linux - Gen10Plus UBM4バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:41:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI (SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>To enter the&nbsp;SSA&nbsp;CLI console type: ssacli</p>\n\n<p>Commands can also be executed from outside the&nbsp;SSA&nbsp;CLI console using the syntax: ssacli</p>\n\n<p>Type &quot;ssacli help&quot; or type &quot;help&quot; at the CLI prompt for usage details.</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"8616016","datemodified":"2022-01-24T07:28:41","file_list":["cp049695.xml","cpqsetup.exe","genericmsi.dll","SSACLI53060_X64.msi"],"md5sum":"716c7b4c444c01d61fcedbdfe452413f","name":"cp049695.exe","release":"2022-01-24T07:26:33","revision":"0","sha1sum":"86ae53909577a9b3c0ca3674ba397cec41eb26c8","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"01e0939311154208bbd5b8d9e5157a9c","version":"62ff2bdde6a44c629dabe0a992a36c01"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator (智慧型儲存管理員 (SSA)) CLI"},{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자(SSA) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:13:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssacli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on ESXi 7.0."},{"lang":"ja","x_late":"このパッケージは、ESXi 7.0.上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"29491295","datemodified":"2022-02-05T16:46:22","file_list":["/CP050370.vmexe64","/CP050370.vmfile","/CP050370.xml","/CP050370_VMw.zip","/payload.json","/README.txt","/CP050370_VMw.zip/index.xml","/CP050370_VMw.zip/vendor-index.xml","/CP050370_VMw.zip/metadata.zip","/CP050370_VMw.zip/vib20/CP050370/HPE_bootbank_CP050370_1.0.4-7.0.0.15525992.vib","/CP050370_VMw.zip/metadata.zip/vendor-index.xml","/CP050370_VMw.zip/metadata.zip/vmware.xml","/CP050370_VMw.zip/metadata.zip/vibs/CP050370-4243289056654294129.xml","/CP050370_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050370_1.0.4-7.0.0.15525992.xml"],"md5sum":"41e1e9659617f37447d13e5199daaa6c","name":"CP050370.zip","release":"2022-02-05T17:17:05","revision":"0","sha1sum":"1740a190495224e77f321b45eb2517b216f5607f","size":"28MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050370","version":"1.0.4-7.0.0.15525992"}]}],"id":{"product":"4a88cfeb4a984c96a13ab1090bcaab71","version":"0c5356cb5528485b9df1b9529545a2d9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"HPE Mellanox Ethernetアダプター専用のオンラインファームウェアアップグレードユーティリティ(ESXi 7.0)"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T11:05:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)</li>\n\t<li>779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li>\n\t<li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following device has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 64-bit to enable the HPE Smart Array P824i-p MR controller.  This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array P824i-p MRコントローラーを有効にする、SRed Hat Enterprise Linux 7 64-bit用のビルド済みバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"709931","datemodified":"2019-01-23T06:18:43","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-957.el7.x86_64","./lib/modules/3.10.0-957.el7.x86_64/extra","./lib/modules/3.10.0-957.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-957.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"ce36b2c24f30c6a27b2d263405701040","name":"kmod-megaraid_sas-07.706.05.00-14.rhel7u6.x86_64.rpm","release":"2019-01-23T06:17:01","revision":"0","sha1sum":"23958aae2c2b99315d7693f3b7825833bb56a506","size":"693KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.706.05.00-14"},{"bytes":"707491","datemodified":"2019-01-23T06:17:14","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-862.el7.x86_64","./lib/modules/3.10.0-862.el7.x86_64/extra","./lib/modules/3.10.0-862.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-862.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"a5085435ddad70efabd99e7c2d00eedd","name":"kmod-megaraid_sas-07.706.05.00-14.rhel7u5.x86_64.rpm","release":"2019-01-23T06:17:01","revision":"0","sha1sum":"07ed629881ce8b16f2dfaa1bafc8bdf50d5e4d5c","size":"690KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"e5dfbd8525114b8cbf5ba28d97ea5b28","version":"23a1452ef14f40e5a32a246d8974f642"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit Red Hat Enterprise Linux 7 "},{"lang":"ja","x_late":"64-bit Red Hat Enterprise Linux 7用HPE SmartアレイP824i-p MRコントローラードライバー "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-22T09:32:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n\n<p>Added support for Red Hat Enterprise LINUX 7 Update 5</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12909287","datemodified":"2021-08-25T06:39:32","file_list":["/CP046765_BUILD_6.data","/CP046765.vmexe","/CP046765.vmexe64","/CP046765.vmfile","/CP046765_VMw.zip","/CP046765.xml","/payload.json","/CP046765_VMw.zip/index.xml","/CP046765_VMw.zip/vendor-index.xml","/CP046765_VMw.zip/metadata.zip","/CP046765_VMw.zip/vib20/CP046765/HPE_bootbank_CP046765_2021.10.01.6-6.7.0.7535516.vib","/CP046765_VMw.zip/metadata.zip/vendor-index.xml","/CP046765_VMw.zip/metadata.zip/vmware.xml","/CP046765_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046765_2021.10.01.6-6.7.0.7535516.xml","/CP046765_VMw.zip/metadata.zip/vibs/CP046765--7573655854639785624.xml"],"md5sum":"3e13d0904116bae6e68c376c05fec207","name":"CP046765.zip","release":"2021-08-25T06:34:05","revision":"0","sha1sum":"3ada67ae4ff78ae35ecfd4597679173b91ebb855","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046765","version":"2021.10.01.6-6.7.0.7535516"}]}],"id":{"product":"91d189194b084bd98d6e01e6c3e2ba6d","version":"a2e8a2cd7fd144f1bb21050ee9b98db4"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Fixed a behavior with internal engineering data display</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware version:</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:623px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Universal Boot Image</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot BIOS</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E Dual Port Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E-T Dual Port Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PCIGen10_1.0.8ts.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.8"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"667152","datemodified":"2021-09-07T03:23:50","file_list":["cp049266.xml","cpqsetup.exe","LICENSE.txt","payload.json","PCIGen10_1.0.8ts.hex","SecureFlash64.dll"],"md5sum":"21ebe546fc05b1ab22eb81be972a9349","name":"cp049266.exe","release":"2021-09-07T03:22:21","revision":"0","sha1sum":"eb08378884290bc4d9cd3f8e7154e4f01ca2b76e","size":"651KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.8"}],"id":{"product":"b81956d2c370432aad5ffc0ea6fc40b3","version":"86b58be3df9b41438b1d81c6e6d74269"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.&nbsp;<br />\n&nbsp;</p>\n\n<p>This component can only be executed on Windows x64.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するために[インストール]ボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。 <br/>\n </p>\n\n<p>このコンポーネントは、Windows x64上でのみ実行できます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Windows x64 - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-12T13:26:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (C) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (C) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.<br />\n&nbsp;</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Fixed an issue of inaccurate temperature readings when the actual temperature exceeds 100 &deg;C on Proliant Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DX360 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：EG000600JWEBHおよびEG000300JWEBFのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5514636","datemodified":"2021-08-25T12:13:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/CP049347.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/STHBUGD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aa9e289524-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049347.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049347.scexe"],"md5sum":"5d1ac611ce46fc28ff461742ba040e81","name":"firmware-hdd-aa9e289524-HPD5-2.1.x86_64.rpm","release":"2021-08-25T11:59:05","revision":"0","sha1sum":"463fb3d71abf2c5ad7ffb0f68f49f5d68b57509f","size":"5MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"9931ebb8026f40e8a799a9d593247da2","version":"b4a748a77b1547dbbbcde3d777743d85"},"installation":{"command":"CP040342.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for Linux (x64) - EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:54:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1023112","datemodified":"2021-11-02T10:13:37","file_list":["cp047051.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"md5sum":"7a479a07369dd260045c6d4e6af80d3f","name":"cp047051.exe","release":"2021-11-02T09:59:48","revision":"0","sha1sum":"8637a98458c0d44e8b3164cad2f32aabefd55d16","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"type_of_change":"0","version":"4.1.239.0"}],"id":{"product":"ab1694a2c3b34d68b6e9d41c15960bf5","version":"905a2c0861344244b1356a88ca224e6e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2019"},{"lang":"ja","x_late":"Windows Server 2019用HPE Intel ixsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXS.dll and ixsmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixs68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5475704","datemodified":"2021-07-23T07:53:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/CP048180.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/SAVNGSD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04257b77b-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048180.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048180.scexe"],"md5sum":"3bd2d27d1e745bc7f030470f1e114933","name":"firmware-hdd-b04257b77b-HPD9-2.1.x86_64.rpm","release":"2021-07-23T07:37:05","revision":"0","sha1sum":"9399a1e1b648dc55f0ff8105290f4de5e8c596a4","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"4cf79b782386458fa01aea2ca94f4962","version":"c99e0b57016c4a9391476f2664d65dfb"},"installation":{"command":"CP040271.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:36:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM2ストレージバックプレーンをアップデートします。\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14019852","datemodified":"2022-02-23T11:17:37","file_list":["/CP051209_BUILD_6.data","/CP051209.vmexe","/CP051209.vmexe64","/CP051209.vmfile","/CP051209_VMw.zip","/CP051209.xml","/payload.json","/CP051209_VMw.zip/index.xml","/CP051209_VMw.zip/vendor-index.xml","/CP051209_VMw.zip/metadata.zip","/CP051209_VMw.zip/vib20/CP051209/HPE_bootbank_CP051209_1.20.6-7.0.0.15843807.vib","/CP051209_VMw.zip/metadata.zip/vendor-index.xml","/CP051209_VMw.zip/metadata.zip/vmware.xml","/CP051209_VMw.zip/metadata.zip/vibs/CP051209--616676442104084304.xml","/CP051209_VMw.zip/metadata.zip/bulletins/Smart-Component-CP051209_1.20.6-7.0.0.15843807.xml"],"md5sum":"709210e113bdfcad85562cb9ed7a58c8","name":"CP051209.zip","release":"2022-02-23T10:57:20","revision":"0","sha1sum":"8e8270ae632bb7750271fbae8bf2e7b7f69f05c8","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.20","vib_list":[{"name":"CP051209","version":"1.20.6-7.0.0.15843807"}]}],"id":{"product":"6c850a8782474532b42a51c8d341beac","version":"c12708ea029943c8aaacc5390629408e"},"installation":{"command":"CP051209.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>「追加情報」に記載されている指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./Execute_Component </li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./ Execute_Component</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor VMware Esxi - Gen10Plus UBM2バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-22T14:07:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL, and EG0900FCSPN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4752379","datemodified":"2021-07-23T08:32:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/CP048075.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/TA13SED2.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7c1a1734f9-HPD2-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048075.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048075.scexe"],"md5sum":"8ee56e8118f23141e9490df5dd254291","name":"firmware-hdd-7c1a1734f9-HPD2-8.1.x86_64.rpm","release":"2021-07-23T08:18:21","revision":"0","sha1sum":"d44d6099d568b3ba6ac6e60463d0d7d8b6c80c03","size":"4MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"a3c9b8269658446e8b8ae9264c4873c2","version":"455b0dea49a2414cbfb34fa2a8d8e324"},"installation":{"command":"CP040300.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-22T16:32:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1050369","datemodified":"2021-01-14T08:12:01","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"391cf277e9181d32d7c8c88c1fb70587","name":"be2iscsi-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"f4c69b955262ad19c50484d5be2e4cd9291156ae","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"978624","datemodified":"2021-01-14T07:58:20","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"2f7e5d427d02ae9abf84cc0848984d27","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:49:05","revision":"0","sha1sum":"8039e9e645120611d5084ceeaa12336dd4d1180b","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"dd5b092a7dec4d3e9ecd257e4f87af47","version":"90e50c8ec51142778ad28c7f963aff19"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 1 and&nbsp;SUSE Linux Enterprise Server 15 Service Pack 2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"58edf963-9038-4e01-80c5-59b770e09e25","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"UBM1_V1.46.signed.hex.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"V1.46"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10Plus UBM1 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"58307","datemodified":"2022-01-12T14:44:08","file_list":["payload.json","UBM1_V1.46.signed.hex.ilo","UBM1_V1.46.xml"],"md5sum":"4e1dfa8aba7927baf7cb0054a10e17ca","name":"UBM1_V1.46.fwpkg","release":"2022-01-12T14:39:02","revision":"0","sha1sum":"4a7144aac5bf43ef2a8865dc592c35dac811cfe2","size":"56KB","target_guids":["9675b54e-1c96-44c3-a7a1-901501000000"],"type_of_change":"1","version":"1.46"}],"id":{"product":"e884951b2d9a4bf7ac25bf0d37a0e37d","version":"ffa225c6f2e7421eba2a635f4f5ce2f8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10 Plus UBM1 Backplane PIC Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-05T10:32:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add Microsoft Windows 2022 to supported lists.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1PIC","sw_key_expectedpath":"firmware:ubmbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp040071.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.20"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10 PlusサーバーのHPE Gen10 Plus Innovation Engine Firmwareをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9035496","datemodified":"2021-04-06T06:47:47","file_list":["cp040070.xml","cp040071.compsig","cp040071.zip","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"bae4af138d4dc3490ee63ad099ef3502","name":"cp040070.exe","release":"2021-06-10T00:00:00","revision":"1","sha1sum":"e5c371ed0a7b6d1d04bd5f4690c8c241cfddfa1d","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.20"}],"id":{"product":"6522bf51105244bfa55540a1e824854d","version":"b7bba3fd5bf842c5a1cf938fb19f235d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Windows x64 - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-18T08:42:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"IE-Gen10Plus","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5706766","datemodified":"2022-02-10T09:48:33","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-qla2xxx","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"b5c847016795fa24864f5f0d9b407732","name":"kmod-qlgc-qla2xxx-10.02.06.03_k1-1.rhel8u5.x86_64.rpm","release":"2022-02-10T09:43:44","revision":"0","sha1sum":"9a4244b5db51e018893e4c59377e7b2a17b31950","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.06.03-k1"}],"id":{"product":"a970944cf8a44d27bcff8a800d52aa6b","version":"ff5fda0470d04c0da1b72c540b0f5312"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qlgc-qla2xxx-10.02.06.02_k1-1.rhel8u5.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 5 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-13T08:40:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.4</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.01.a2-k1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for RHEL 8.5</p>\n\t</li>\n</ul>\n\n<p>Updated to driver version 10.02.06.03-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在Red Hat Enterprise Linux 7 x86_64下运行的HPE Intel i40e以太网网卡的SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"93612","datemodified":"2021-08-24T16:04:46","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/f9d6f321c1f914d626f033175748e6749dcddf","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"9a3738c394b2dbcf7c79a0f3421d655c","name":"kmod-hp-iavf-4.2.7-1.rhel7u9.x86_64.rpm","release":"2021-08-24T15:53:07","revision":"0","sha1sum":"5c4379846e41e137b091697fbd6c7b0111bbf080","size":"91KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"93613","datemodified":"2021-08-24T16:03:35","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/257c89ae6a7b38a70c5af45a31cc1bbf0792ad","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"a6c17788e21c7c0a47a5c54849bbf848","name":"kmod-hp-iavf-4.2.7-1.rhel7u8.x86_64.rpm","release":"2021-08-24T15:53:07","revision":"0","sha1sum":"a3c528f42200cbf1a300c25f603a7ba3bb0a54e5","size":"91KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"58d1a656061f4ce896db266c33677e70","version":"0630783d3c9e46cc8079f656dc99496a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4004984","datemodified":"2021-07-23T19:34:44","file_list":["cp048556.xml","cpqsetup.exe","payload.json","setup.dll","WRN620G6.rel"],"md5sum":"294c024a093b6c2e3f9d6bb560a82f8f","name":"cp048556.exe","release":"2021-07-23T19:27:07","revision":"0","sha1sum":"6941cad46207194e08ceaafea3192d9b20381285","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"39fa471cea234b3883e794de990ad252","version":"f01d43e61e884cdfa32bd4d4d12c1966"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:29:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_2CQDA2_O_SEC_3p00_PLDMoMCTP_80008271.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-2CQDA2 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-2CQDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter</td>\n\t\t\t<td>80008271</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t\t<th>NVMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター</td>\n\t\t\t<td>80008271</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2992.0は以下を含みます：インテル(R)ブートエージェントICE v2.5.0およびUEFI x64 100ギガビットドライバーv3.0.11。</p>\n"}],"files":[{"bytes":"10517832","datemodified":"2021-08-13T13:10:13","file_list":["HPE_E810_2CQDA2_O_SEC_3p00_PLDMoMCTP_80008271.HPb","HPE_E810_2CQDA2_O_SEC_3p00_PLDMoMCTP_80008271.xml","payload.json"],"md5sum":"c5f2ed002fa37cbe9cefa7e3b5962763","name":"HPE_E810_2CQDA2_O_SEC_3p00_PLDMoMCTP_80008271.fwpkg","release":"2021-09-16T00:00:00","revision":"2","sha1sum":"c53c65fbb38365b3592653993a6ee1943f2f65c5","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-15928086000e"],"type_of_change":"1","version":"3.00"}],"id":{"product":"58e30c6460374d34ab64c2a8547dafe2","version":"34800c0623f84cc68080e09989d128ab"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-2CQDA2 Ethernet 100Gb 2ポートQSFP28アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-13T03:50:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_2CQ2_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1345.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12900501","datemodified":"2021-08-25T05:58:25","file_list":["/CP046754_BUILD_8.data","/CP046754.vmexe","/CP046754.vmexe64","/CP046754.vmfile","/CP046754_VMw.zip","/CP046754.xml","/payload.json","/CP046754_VMw.zip/index.xml","/CP046754_VMw.zip/vendor-index.xml","/CP046754_VMw.zip/metadata.zip","/CP046754_VMw.zip/vib20/CP046754/HPE_bootbank_CP046754_2021.10.01.8-6.7.0.7535516.vib","/CP046754_VMw.zip/metadata.zip/vendor-index.xml","/CP046754_VMw.zip/metadata.zip/vmware.xml","/CP046754_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046754_2021.10.01.8-6.7.0.7535516.xml","/CP046754_VMw.zip/metadata.zip/vibs/CP046754-8988436774523808914.xml"],"md5sum":"76abf4ba48bd2728709e7be4f4190152","name":"CP046754.zip","release":"2021-08-25T05:53:20","revision":"0","sha1sum":"42d37b948898aeb001e2b474e0724b7cb9bf4780","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046754","version":"2021.10.01.8-6.7.0.7535516"}]}],"id":{"product":"783998957ee142cfa68787b55e3611e4","version":"7249a067e26f4c4ba0f1d76f3f1e6b79"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed a behavior with internal engineering data displays</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5896973","datemodified":"2021-07-23T10:31:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/CP048094.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/WRH620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc4af697b-HPG6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048094.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048094.scexe"],"md5sum":"2d95c8896c120ef53ebccda7a6c9fc5d","name":"firmware-hdd-bfc4af697b-HPG6-5.1.x86_64.rpm","release":"2021-07-23T10:19:04","revision":"0","sha1sum":"8cb1f087b6f16dcbb486b45c78dbe9c3138eb13e","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"6114e7f77ac240e69cf280b518ec5e27","version":"5c7858b769d34fe8aed68430b80ef77f"},"installation":{"command":"CP040778.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:15:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"3406206","datemodified":"2022-02-08T13:37:03","file_list":["/cp049608.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/index.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/vendor-index.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/metadata.zip","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/vib20/sut/HPE_bootbank_sut_701.2.9.1.16-1OEM.701.0.0.16850804.vib","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/metadata.zip/vendor-index.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/metadata.zip/vmware.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/metadata.zip/vibs/sut-4961749315775369943.xml","/sutComponent_701.2.9.1.9-0-signed_component-19330218.zip/metadata.zip/bulletins/sutComponent_701.2.9.1.9-0.xml"],"md5sum":"e4717a9746056efba8778190a016d442","name":"cp049608.zip","release":"2022-02-08T13:36:19","revision":"0","sha1sum":"8ce5e51477969f9e23929c50c78c489925978e68","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"sut","version":"701.2.9.1.16-1OEM.701.0.0.16850804"}]}],"id":{"product":"113bb71009854458ba860147296f93b4","version":"88be833e82074dd38ec766488c004891"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HPE Smart Update Manager (SUM) from the HPE Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Copy&nbsp;this component&nbsp;to the directory<em>&nbsp;/SPP20xxxxx/packages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to&nbsp;<em>/packages</em>&nbsp;and execute ./smartupdate.bat or ./smartupdate.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the iLO of the ESXi host to be updated.</li>\n\t<li>Enter the iLO credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager&nbsp;instructions&nbsp;to complete the Component update.</li>\n</ol>\n\n<p>This&nbsp;method works if this component is already installed on the ESXi host and is running in the Auto mode.</p>\n\n<p>Refer&nbsp;Server updates through iLO 5 in <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmiS7agzZPZ\">SUM User Guide</a></p>\n\n<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the component bundle.</li>\n\t<li>Run the &quot;esxcli software component apply&quot; command&nbsp;to install the component bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-21T09:52:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhyMagzZPY\">iSUT Release Notes</a> for information about the enhancements added&nbsp;in this release</p>\n","latest_fixes_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhxlqgzZPY\">iSUT Release Notes</a> for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhyMagzZPY\">iSUT Release Notes</a> for information about the enhancements added&nbsp;in this release</p>\n","curr_fixes_x_late":"<p>See the <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/solutions/info-library/index.aspx?cat=smartupdate&amp;subcat=isut#.XmhxlqgzZPY\">iSUT Release Notes</a> for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sutComponent:701.2.9.1.9-0","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Broadcom NetXtreme-E NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"334965","datemodified":"2021-10-01T17:49:17","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnxt_en.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"41d3c720e70c3954bcb8eff7b56c6207","name":"bnxt_en-kmp-default-1.10.2_k5.3.18_22-219.0.55.0.sles15sp2.x86_64.rpm","release":"2021-10-01T17:31:59","revision":"0","sha1sum":"7b4bf980237d75ab70d6044ec1a0cf5dc847d518","size":"327KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-219.0.55.0"},{"bytes":"339038","datemodified":"2021-10-01T17:50:28","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/bnxt_en.ko","./lib/modules/5.3.18-57-default/updates/drivers","./lib/modules/5.3.18-57-default/updates/drivers/infiniband","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"10dfd73acecd0f2b85b113b81690c2c5","name":"bnxt_en-kmp-default-1.10.2_k5.3.18_57-219.0.55.0.sles15sp3.x86_64.rpm","release":"2021-10-01T17:31:59","revision":"0","sha1sum":"78d5f98b033289296d3452f016ea5a2fafb485a1","size":"331KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-219.0.55.0"}],"id":{"product":"2ed4fb56e81f45b0b8ae601a61b78e6c","version":"818ea38e64a741c29a08bc997f240334"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports SUSE Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n\t<li>This product addresses an issue where Virtual Functions (VFs) cannot be configured while the Physical Function (PF) interface is administratively down.</li>\n\t<li>This product addresses an issue where system crash when driver unloads while firmware reset is in progress.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5上で動作するHPE Blade Intel ixgbenアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.11.0.</p>\n"}],"files":[{"bytes":"196126","datemodified":"2021-03-31T14:47:17","file_list":["/cp045171.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.11.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-ixgben-1.9.11.0.xml","/VMW-ESX-6.5.0-ixgben-1.9.11.0-offline_bundle-17672460.zip/metadata.zip/vibs/ixgben-7460454770853794822.xml"],"md5sum":"cd4f7992329d57e15fbd48810ef87e06","name":"cp045171.zip","release":"2021-03-31T14:45:04","revision":"0","sha1sum":"2251152a56f7aa7724e7e9c4503a403672a977b6","size":"191KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.04.19","vib_list":[{"name":"ixgben","version":"1.9.11.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"7c150c6f26c6491f9b995cd907650c31","version":"5a83cd2ae373440ab5f6ad38395e5765"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade Intel ixgbenドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"<p>This product addresses VF issues when calculating, reset PF interface, link state propagation and VLAN trunk scenarios.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.9.11.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic FastLinQ 10/25/50 GbE Server Adapters for Microsoft Windows Server 2016, Microsoft Windows Server 2019 and Microsoft Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE QLogic FastLinQ 10/25/50 GbEサーバーアダプタードライバーfor Microsoft Windows Server 2016、Microsoft Windows Server 2019、およびMicrosoft Windows Server 2022を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>Marvell Windows FastLinQ Ethernet VBD, 8.58.16.0</li>\n\t<li>Marvell Windows FastLinQ Ethernet VBD Client, 8.58.12.0&nbsp;</li>\n\t<li>Marvell Windows FCoE Offload Driver, 8.58.1.0</li>\n\t<li>Marvell Windows FCoE Crash-dump Driver, 8.58.1.0</li>\n\t<li>Marvell Windows iSCSI Crash-dump Driver, 8.58.1.0</li>\n\t<li>Marvell Windows iSCSI Offload Driver, 8.58.1.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>このコンポーネントは、以下のドライバーを含みます。</p>\n\n<ul>\n\t<li>Marvell Windows FastLinQイーサーネットVBD、8.58.16.0</li>\n\t<li>Marvell Windows FastLinQイーサーネットVBDクライアント、8.58.12.0 </li>\n\t<li>Marvell Windows FCoEオフロードドライバー、8.58.1.0</li>\n\t<li>Marvell Windows FCoEクラッシュダンプドライバー、8.58.1.0</li>\n\t<li>Marvell Windows iSCSIクラッシュダンプドライバー、8.58.1.0</li>\n\t<li>Marvell Windows iSCSIオフロードドライバー、8.58.1.0</li>\n</ul>\n"}],"files":[{"bytes":"3505384","datemodified":"2021-11-17T12:07:09","file_list":["cp049989.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"md5sum":"099ea7debd333b6d825f3eb24368c681","name":"cp049989.exe","release":"2021-11-17T11:51:48","revision":"0","sha1sum":"23156e8eab62c16067a8ad45209e77807d325e57","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"1","version":"8.58.20.0"}],"id":{"product":"ff242e39c275472185612592300114ce","version":"a85635d911b944be9167836aae4ddcff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"Windows Server x64 Edition用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bf","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002be","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002c0","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021f","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021f","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021a","type":"pci","ven":"1077"},{"dev":"8080","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80801590021b","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021a","type":"pci","ven":"1077"},{"dev":"8084","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80841590021b","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021a","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-17T08:10:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where RoCE+L2 traffic on MOS in NPAR mode</li>\n\t<li>This product correct an issue where transmitting under heavy PAUSE/Priority-based Flow Control (PFC)</li>\n\t<li>This product correct an issue where turning off VMs while VF RDMA traffic is running</li>\n\t<li>This product correct an issue where yellow bang while running VF RoCE traffic with overnight switch port.</li>\n\t<li>This product correct an issue where installing dirvers with iSCSI enumerated.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qevbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1647068","datemodified":"2021-08-27T06:03:12","file_list":["./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12","./opt/broadcom/rhel7/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/i386/lib/libbrcmemsdm.so","./opt/broadcom/rhel7/i386/lib/libbrcmhbaapi.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel7/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel7/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel7/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"b0b39ba7720901e73c45c33db993b685","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel7.x86_64.rpm","release":"2021-08-27T05:55:55","revision":"0","sha1sum":"4f6e926b8609d2bfc3cece714f6b6b7a0e77ce59","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"7821f460e2f3488c95e92c25e76c9d75","version":"f7252735bfd0469d9ff89c95bc9dfde7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Users will automatically be logged out after a predetermined period of inactivity when using&nbsp;SSA&nbsp;and will have to re-login.</p>\n\n<p>On the Web-based Management Device Homepage, under &quot;options&quot;, &quot;Anonymous Access&quot; should be enabled when using SSA.</p>\n\n<p>When clicking on a controller that is currently being configured in a different&nbsp;SSA&nbsp;session, a message will appear which allows you to override the other&nbsp;SSA&nbsp;session or cancel. If you choose to override the other&nbsp;SSA&nbsp;session, any unsaved changes in the other session will be discarded.</p>\n\n<p>To uninstall SSA, use Add/Remove Programs located in the Control Panel on Windows Systems.</p>\n\n<p>To run&nbsp;SSA&nbsp;in local application mode on Windows, Internet Explorer must be the default browser.</p>\n\n<p><strong>The following are known issues:</strong></p>\n\n<ul>\n\t<li>Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.</li>\n</ul>\n"}],"files":[{"bytes":"9904888","datemodified":"2022-01-24T07:26:14","file_list":["cp049694.xml","cpqsetup.exe","genericmsi.dll","SSA53060_X64.msi"],"md5sum":"5507574cf88fa51291dfdaf870f7649b","name":"cp049694.exe","release":"2022-01-24T07:23:43","revision":"0","sha1sum":"15df1e24eba75781c5100331f4aeefa50affe9bc","size":"9MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"594618f566cc4fbca055e8866278e53d","version":"3df4d468b3a64d759ccdb48bff666bb6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. \n<P>From that drive and directory, execute the downloaded file. \n<P>Click the \"Install\" button to proceed with the installation. The utility will automatically be installed.</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Windows 64-bit"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:10:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_265.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.65"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Linux Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HP Smart Update Manager."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるLinuxオペレーティングシステムに直接インストール可能なアップデートされたiLOファームウェアを提供します。このコンポーネントは、iLOユーザーインターフェイス、ユーティリティ、またはスクリプティングインターフェイスからファームウェアイメージのアップデートを入手するために使用することができます。さらに、HP Smart Update Managerと一緒に使用することが出来ます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"33936300","datemodified":"2022-02-24T05:11:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/CP049683.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/ilo5_265.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-2.65-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049683.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049683.scexe"],"md5sum":"50ea444cf99f3937ba600b7768786c43","name":"firmware-ilo5-2.65-1.1.x86_64.rpm","release":"2022-02-24T04:56:08","revision":"0","sha1sum":"d8895a0d54e9ebad174c40937e12343f8a3af709","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"2.65"}],"id":{"product":"8aa4f1e30dfc4417885cea85b551314e","version":"294473b23b52476585c0d25cea8812b5"},"installation":{"command":"sh CP0XXXXX.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Below are the steps to install/upgrade Linux Smart Component rpm files</strong></p>\n\n<p style=\"margin-left:40px\">Extract the rpm file using the command &lsquo;rpm2cpio &lt;filename&gt; | cpio &ndash;idmv&rsquo;<br />\nNavigate to /usr/lib/x86_64-linux-gnu/firmware-ilo5-ri11-1.40-1.1<br />\nRun the &lsquo;hpsetup&rsquo; file using the command ./hpsetup or ./hpsetup &ndash;f when updating to same version</p>\n\n<p style=\"margin-left:40px\">&nbsp;</p>\n\n<p><strong>To install the Linux Smart Components perform the below steps</strong></p>\n\n<p style=\"margin-left:40px\">Extract the RPM file and navigate to /usr/lib/x86_64-linux-gnu.<br />\nTo use the Set up file, navigate to firmware-ilo5-2.xx-1.1 folder and run the same.<br />\nTo use .scexe files, navigate to hp-scexe-compat or scexe-compat folders and run the same.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86)","platform":"red_hat_enterprise_linux_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86)","platform":"red_hat_enterprise_linux_client_x86","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (x86)","platform":"suse_linux_enterprise_server_x86","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Support for Cloud based management with Compute Ops Manager (COM).</li>\n\t<li>Support for Enhanced Download Performance\n\t<ul>\n\t\t<li>This option allows to improve the performance of iLO Scriptable Virtual Media and URL based Firmware update in environments with high network latencies.</li>\n\t</ul>\n\t</li>\n\t<li>Support &nbsp;for NVIDIA A2 PCIE GPU card</li>\n</ul>\n","latest_fixes_x_late":"<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"<p>Initial build</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16695679","datemodified":"2021-08-27T13:08:15","file_list":["/CP048445_BUILD_2.data","/CP048445.vmexe","/CP048445.vmexe64","/CP048445.vmfile","/CP048445_VMw.zip","/CP048445.xml","/payload.json","/CP048445_VMw.zip/index.xml","/CP048445_VMw.zip/vendor-index.xml","/CP048445_VMw.zip/metadata.zip","/CP048445_VMw.zip/vib20/CP048445/HPE_bootbank_CP048445_HPD8.2-7.0.0.15843807.vib","/CP048445_VMw.zip/metadata.zip/vendor-index.xml","/CP048445_VMw.zip/metadata.zip/vmware.xml","/CP048445_VMw.zip/metadata.zip/vibs/CP048445--8748020149411627963.xml","/CP048445_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048445_HPD8.2-7.0.0.15843807.xml"],"md5sum":"4a29de7bb7907d392f8de44d4d8d402d","name":"CP048445.zip","release":"2021-08-27T13:03:11","revision":"0","sha1sum":"1a2b3e4c8c9af3978de1be8d204d4c60249d1725","size":"15MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048445","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"bda7d035201d46ffadf44995b633fe12","version":"e898706727e04734811374fee915f4b7"},"installation":{"command":"CP042629.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:10:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel E1R Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1074776","datemodified":"2021-08-15T05:41:51","file_list":["cp047044.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"9b475d94a0517a961a472e0add6c105d","name":"cp047044.exe","release":"2021-08-15T05:24:28","revision":"0","sha1sum":"cffb41264a01b5915e994f327f0d7e0700818d91","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"0","version":"12.18.12.1"}],"id":{"product":"87793aff72a54849a327ce026784372d","version":"a7994178081648348df447829ef20992"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel E1Rドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"e1r68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"8150944","datemodified":"2021-07-25T12:43:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/CP048503.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b45e49679c-HPK4-6.1/spannsK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048503.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048503.scexe"],"md5sum":"1be7b1ebde1b2745e6ace26775266471","name":"firmware-hdd-b45e49679c-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:29:06","revision":"0","sha1sum":"63a2ed12d83ba7aa46948b1e822ce82a6fd1dd72","size":"7MB","target_guids":["562340a5-304b-3130-3932-304b57445548","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3430-304b5744554b"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ff420d2a518645bca112d4ae29440c26","version":"e444ab28e4254d73be14cfa7db235fec"},"installation":{"command":"CP040920.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"Linux用オンラインNVMe SSDフラッシュコンポーネント（x64）- MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:45:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2016, Windows Server 2019 and Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>&nbsp;10/20 Gigabit Ethernet VBD Driver 7.13.206.0</li>\n\t<li>&nbsp;iSCSI Offload Driver &nbsp;7.14.17.0</li>\n\t<li>&nbsp;Unified iSCSI Crash Dump Driver 7.13.5.0</li>\n\t<li>&nbsp;Network Adapter NDIS VBD Client 7.13.198.0&nbsp;</li>\n\t<li>&nbsp;FCoE Offload driver &nbsp;7.14.24.0</li>\n\t<li>&nbsp;FCoE Crash Dump Driver 7.13.7.0</li>\n</ul>\n"}],"files":[{"bytes":"3410120","datemodified":"2021-08-11T06:48:43","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp047060.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"md5sum":"0f6bfa29d62567b4d8e14c0d31144d19","name":"cp047060.exe","release":"2021-09-02T00:00:00","revision":"1","sha1sum":"3dcf0f53f221e5ccf60407dfd8467aef8349cce2","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"1","version":"7.13.206.0"}],"id":{"product":"88920b6128524213bc79e665d9b3a53b","version":"e3da2478d8cf4a528522a0aa7ca98b85"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"2231","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c2231","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-17T06:05:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where System crash while upgrading with NPAR SRIOV-EP mode enabled.</li>\n\t<li>This product correct an issue where BSOD in Windows NDIS driver while in WS2022 PCS Configuration.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where System crash while upgrading with NPAR SRIOV-EP mode enabled.</li>\n\t<li>This product correct an issue where BSOD in Windows NDIS driver while in WS2022 PCS Configuration.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム用のRoCEv2対応HPE 25GbイーサーネットアダプターおよびHPE 100GbイーサーネットアダプターをサポートするHPE NVMeネームサーバーホストエージェントキットが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"83522","datemodified":"2022-01-24T08:42:14","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"4446a2cc3f4417ce6edb0136590f7db9","name":"HPE-NFC-host-agent-RHEL-1.1-1.rhel8u4.x86_64.rpm","release":"2022-01-24T08:39:00","revision":"0","sha1sum":"883996b36586e2ba04eba360eb602b2facf68809","size":"81KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd07551d5"],"type_of_change":"1","version":"1.1-1"},{"bytes":"83522","datemodified":"2022-01-24T08:39:50","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"8f922575bd20ce12d5342b30864d7686","name":"HPE-NFC-host-agent-RHEL-1.1-1.rhel7u9.x86_64.rpm","release":"2022-01-24T08:39:00","revision":"0","sha1sum":"431f2c6f05a63a2ec3b3b2d0004b577a61538bd1","size":"81KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd07551d5"],"type_of_change":"1","version":"1.1-1"},{"bytes":"83521","datemodified":"2022-01-24T08:45:09","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"2b78413b47535897fd4d876dcd964c4d","name":"HPE-NFC-host-agent-RHEL-1.1-1.rhel7u8.x86_64.rpm","release":"2022-01-24T08:39:00","revision":"0","sha1sum":"44006cf97251e402e0a6b6b3ffd3d72ab88f0c1a","size":"81KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd07551d5"],"type_of_change":"1","version":"1.1-1"},{"bytes":"83523","datemodified":"2022-01-24T08:41:03","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-RHEL/component.xml"],"md5sum":"1c1e9917d58b723ae4a5b17a1dc48f32","name":"HPE-NFC-host-agent-RHEL-1.1-1.rhel8u5.x86_64.rpm","release":"2022-01-24T08:39:00","revision":"0","sha1sum":"0990bbadd4acfc9d958c248b17423814f07271c9","size":"81KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd07551d5"],"type_of_change":"1","version":"1.1-1"}],"id":{"product":"c48bc2a5906e4288a0300950c2ec6126","version":"fa0e64109b534cac8542c13d854e176e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for RedHat Enterprise Linux(RHEL) Server -7/8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"037D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101d1590037d","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 1.0-1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.1-1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-RHEL","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4853612","datemodified":"2021-07-26T17:30:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/CP049133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/TA14SXe0HPD7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049133.scexe"],"md5sum":"f9fffdad5ecfd73b42b497ea8864d239","name":"firmware-hdd-c7df7ceedb-HPD7-2.1.x86_64.rpm","release":"2021-07-26T17:18:04","revision":"0","sha1sum":"3c70e577311d16f085c91433b1c22c7f9d899d4e","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"e3abad55c63d42f3bfc00d8212a8e9d4","version":"6af5a02141ff41d29b6552e85c3dd55d"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP.&lt;nnnnnn&gt;scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:14:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34218288","datemodified":"2022-02-21T05:31:39","file_list":["A43_2.56_02_10_2022.signed.flash","cp050442.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"0104488321da51208fe2434cd7087803","name":"cp050442.exe","release":"2022-02-21T05:29:37","revision":"0","sha1sum":"7ba12fb24f75fa2a2a6db89e7c9f5dc8cddef83a","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"707f07cb4d404d119f2788d168e17586","version":"6babd05ba9d449829d9b7bc933dcfc8d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T06:05:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp;</strong> &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5973297","datemodified":"2021-08-16T11:13:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/CP049283.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/TACD6ALLGPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049283.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049283.scexe"],"md5sum":"940fb0268c8915d6a24b54a34dccf016","name":"firmware-hdd-6fc985bd3b-GPK3-2.1.x86_64.rpm","release":"2021-08-16T11:00:06","revision":"0","sha1sum":"dd73092964dd0f6d4a180ec65eee6097fcf228ac","size":"5MB","target_guids":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433","002340a5-434b-3644-584c-554c39363047"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"2e5a37814cc1401a951db2b5be91b6b3","version":"8874b7c6f603458999b5e771bcfb2e4d"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:55:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 7 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージには、Red Hat Enterprise Linux 7 Server上でEmulexホストバスアダプターおよびメザニンホストバスアダプターに対してHPE Storageファイバーチャネルアレイ接続を有効にするためのユーティリティとライブラリが含まれています。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1762341","datemodified":"2021-11-15T07:07:13","file_list":["./opt/emulex/rhel7/i386/lib/libdfc.so","./opt/emulex/rhel7/i386/lib/libdfc.so.12","./opt/emulex/rhel7/i386/lib/libdfc.so.12.8.526","./opt/emulex/rhel7/i386/lib/libemsdm.so","./opt/emulex/rhel7/i386/lib/libemulexhbaapi.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel7/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/rhel7/x86_64/lib64/libemsdm.so","./opt/emulex/rhel7/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"38e802b86206679639220871d2122134","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.rhel7.x86_64.rpm","release":"2021-11-15T06:56:40","revision":"0","sha1sum":"f3f0b76f89207cc4577eca96547324f8cd847d47","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.526.0"}],"id":{"product":"86a63f267d0441379f1742c69a628a0a","version":"0cf20886c0a94d2697365560cc3e6a0c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"},{"lang":"ja","x_late":"<p>イネーブルメントキットのインストール前にターゲット環境にlibHBAAPIパッケージをインストールしておく必要があります。（存在していない場合、libHBAAPIパッケージはオペレーティングシステムのインストールメディアから取得することができます。）</p>\n\n<p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 7 Server"},{"lang":"ja","x_late":"HPE Emulexファイバーチャネルイネーブルメントキットforホストバスアダプターおよびメザニンホストバスアダプター - Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"lang":"ja","x_late":"HPE Storageファイバーチャネル(FC)アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター(HBA)ドライバーを提供する、バージョン12.8.351.7 のEmulex Storportドライバーfor Extended Systemが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2322856","datemodified":"2021-11-15T03:48:00","file_list":["cp049962.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"c04d374c295bf0426fdd6d08844e151b","name":"cp049962.exe","release":"2021-11-15T03:45:14","revision":"0","sha1sum":"50e3b1074326ba8b91cea9d94516774a28d379d6","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"C8510","version":"72629128a45d40e89f17327480e12812"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"},{"lang":"ja","x_late":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000GFECR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17251527","datemodified":"2021-08-27T04:46:57","file_list":["/CP048381_BUILD_2.data","/CP048381.vmexe","/CP048381.vmexe64","/CP048381.vmfile","/CP048381_VMw.zip","/CP048381.xml","/payload.json","/CP048381_VMw.zip/index.xml","/CP048381_VMw.zip/vendor-index.xml","/CP048381_VMw.zip/metadata.zip","/CP048381_VMw.zip/vib20/CP048381/HPE_bootbank_CP048381_HPG6.2-7.0.0.15843807.vib","/CP048381_VMw.zip/metadata.zip/vendor-index.xml","/CP048381_VMw.zip/metadata.zip/vmware.xml","/CP048381_VMw.zip/metadata.zip/vibs/CP048381-4290166914378001619.xml","/CP048381_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048381_HPG6.2-7.0.0.15843807.xml"],"md5sum":"aafbffd66d305a264a191a594b5bdc67","name":"CP048381.zip","release":"2021-08-27T04:42:06","revision":"0","sha1sum":"01f630cc05cdb20d605d41c97eeabc3f8186901f","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048381","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"4e50152f0d024f97a52057a7a5220f5a","version":"0d5a0f4924e34b289904c41a3dc4dc62"},"installation":{"command":"CP040516.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:02:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34212832","datemodified":"2022-02-21T12:43:41","file_list":["A46_2.56_02_10_2022.signed.flash","cp050500.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"bb5756341e9feb4161ce7b45430b9ca5","name":"cp050500.exe","release":"2022-02-21T12:41:32","revision":"0","sha1sum":"bde4cd7b277a932147ad276f17cf527d30f3a4a6","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"d00882018d64492aa4a5bc81f394c4dc","version":"688230209a7046d297ad551c7cf70c29"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T17:19:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4291480","datemodified":"2021-07-23T18:39:07","file_list":["cp048666.xml","cpqsetup.exe","HVLAnAsseFD2.rel","payload.json","setup.dll"],"md5sum":"54f4ef06d5cef500e5f570736d440ed1","name":"cp048666.exe","release":"2021-07-23T18:31:04","revision":"0","sha1sum":"86ab7c9f7499d45200f09f1b47b52b3291dbe205","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"96853662d13b4def814a5c153a747271","version":"3826386021f54d878029e73b1711e4cd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000JWKGUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:18:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16965579","datemodified":"2022-01-17T06:55:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/CP050005.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/U60_1.54_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u60-1.54_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050005.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050005.scexe"],"md5sum":"f2f5d17605c01381d9a2688f968de7bb","name":"firmware-system-u60-1.54_2022_01_13-1.1.x86_64.rpm","release":"2022-01-17T06:47:11","revision":"0","sha1sum":"1c8844a7bea4a1065faac265b0be50064aa63ee5","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"52c884546e0a44fb8cddfd654ad71e81","version":"9e5cc7e892e44204ae193e90656faeca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL20 Gen10 Plus サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T03:22:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"U60","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6929836","datemodified":"2021-08-16T17:02:17","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"59301d9bfaac866bb704a063dd6ca537","name":"kmod-netxtreme2_bl-7.14.80-5.rhel7u9.x86_64.rpm","release":"2021-08-16T16:39:27","revision":"0","sha1sum":"537354133b7824b04c69f428770daa42aedb8557","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"6927796","datemodified":"2021-08-16T17:05:18","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"1ebb033a6754e233c0a0a89bb51da8a6","name":"kmod-netxtreme2_bl-7.14.80-5.rhel7u8.x86_64.rpm","release":"2021-08-16T16:39:27","revision":"0","sha1sum":"7e1cee13ed0a0aa3d094d020e91507b8a5081a02","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"690ed2c76a80449da0cbf178bbdf3cd5","version":"a9d334fd35d64c52b833a58b6cf78336"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with firmware version 1.5.x.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0 includes the latest Fiber Channel and Storage libraries."},{"lang":"ja","x_late":"HPEファイバーチャネルおよびストレージ イネーブルメント バンドルsmartコンポーネントfor ESXi 7.0 には、最新のファイバーチャネルおよびストレージライブラリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6656340","datemodified":"2021-09-01T01:47:12","file_list":["/cp047521.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/vendor-index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/vib20/fc-enablement/HPE_bootbank_fc-enablement_700.3.8.0.6-1OEM.700.1.0.15843807.vib","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vendor-index.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vmware.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/vibs/fc-enablement-1807629225033749204.xml","/fc-enablement-component_700.3.8.0.6-1_18506758.zip/metadata.zip/bulletins/fc-enablement-component_700.3.8.0.6-1.xml"],"md5sum":"d11a0e12a83f2b1ef7273959ad4547c3","name":"cp047521.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"b894bd6cab9c222556de5c1bfb96ca3f27a5f7c8","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbf0a9496","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"fc-enablement","version":"700.3.8.0.6-1OEM.700.1.0.15843807"}]}],"id":{"product":"f97eb4848b18499fa1a1379ab7b46d05","version":"2324e553b65441b3bfdadca7c5dc2b72"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Fiber Channel and Storage Enablement Bundle Smart Component for ESXi 7.0"},{"lang":"ja","x_late":"HPEファイバーチャネルおよびストレージ イネーブルメント バンドル Smart コンポーネント for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"7500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T22:28:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports VMware ESXi 7.0 U2 and ESXi 7.0 U3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Supports VMware ESXi 7.0 U2 and ESXi 7.0 U3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"fc-enablement-component:700.3.8.0.6-1","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"fc-enablement:700.3.8.0.6-1OEM.700.1.0.15843807","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2990568","datemodified":"2021-07-26T20:08:06","file_list":["cp049146.xml","cpqsetup.exe","payload.json","setup.dll","TAPM5ALLHPD9.rel"],"md5sum":"2882bd8c4dbbb0e6ff43f0c4eea60a23","name":"cp049146.exe","release":"2021-07-26T20:00:05","revision":"0","sha1sum":"19d8185d8b789b1b16cd4ef1c99a3ed88ac14d4c","size":"2MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"9141b4ee76c74b70a4eb2f021bfa217f","version":"5f88613e063c4dff95201f419e453e8f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネントfor Windows (x64) - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T19:56:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.1.17.0</li>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1400664","datemodified":"2021-08-11T14:00:34","file_list":["/cp047871.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.650.0.0.4598673.vib","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qcnic-478720060.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3f-1875916866.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3i--1959034772.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/vibs/qfle3-876788810.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3-1.1.17.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qcnic-1.0.59.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3f-1.1.25.0.xml","/MRVL-E3-Ethernet-iSCSI-FCoE-1.0.143-offline_bundle-18284876.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-qfle3i-1.1.5.0.xml"],"md5sum":"836aaaed4f51a8ee4436430a005c4038","name":"cp047871.zip","release":"2021-08-11T13:57:15","revision":"0","sha1sum":"15306f031b3601fec47593aeab53d5e94c9d1819","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qfle3","version":"1.1.17.0-1OEM.650.0.0.4598673"},{"name":"qcnic","version":"1.0.59.0-1OEM.650.0.0.4598673"},{"name":"qfle3f","version":"1.1.25.0-1OEM.650.0.0.4598673"},{"name":"qfle3i","version":"1.1.5.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"5cd2c31f18d541c09e937a83715365ee","version":"ea4d94a465f64c618340616c238eef26"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an incorrect MTU value displayed by the ESXCLI tool.</p>\n"},{"curr_enhancements_x_late":"<p>This products enhances the mechanism that collation of data log.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qfle3:1.1.17.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:1.0.59.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.19.51"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含可升級 HPE ProLiant Broadcom NX1 Gigabit 乙太網路網路卡啟動碼、PXE、UEFI、NCSI 及 CCM 碼的公用程式與二進位檔，適用於 Linux x86_64。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, and CCM code running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE ProLiant Broadcom NX1 기가비트 이더넷 NIC 부팅 코드, PXE, UEFI, NCSI 및 CCM 코드를 업그레이드하기 위한 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包内含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE ProLiant Broadcom NX1千兆以太网卡启动代码、PXE、UEFI、NCSI和CCM代码。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v20.19.31 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>NCSI Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 330i Adapter (22BD)</td>\n\t\t\t<td>2.10</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.30</td>\n\t\t\t<td>21.6.28</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 331i Adapter (22BE)<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331FLR Adapter<br />\n\t\t\tHPE Ethernet 1Gb 4-port 331T Adapter</td>\n\t\t\t<td>1.46</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.30</td>\n\t\t\t<td>21.6.28</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 332i Adapter (22E8)<br />\n\t\t\tHPE Ethernet 1Gb 2-port 332T Adapter</td>\n\t\t\t<td>1.42</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.30</td>\n\t\t\t<td>21.6.28</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"3702669","datemodified":"2021-12-13T06:10:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/CP050424.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/CP050424.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/CPINIT","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/330i-2x1G-14E4-1665-103C-22BD.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-broadcom-2.29.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050424.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050424.scexe"],"md5sum":"c9ae1081c434621d70a992cc9dacc681","name":"firmware-nic-broadcom-2.29.0-1.1.x86_64.rpm","release":"2021-12-13T05:58:40","revision":"0","sha1sum":"d4aeceb042e077bc9f3e622031d37d34cdae5a33","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"2.29.0"}],"id":{"product":"bf3a285848ac4632b8eb3d00276b79b4","version":"52781ffb5cd14c048ec4572ed03e3c9f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP049944.txt file.The results of the firmware upgrade are saved&nbsp;in CP049944.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"Linux x86_64版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T08:56:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addressed the firmware update failure problem while running the installation under Linux OS.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16965218","datemodified":"2022-01-17T06:41:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/CP050003.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/U61_1.54_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u61-1.54_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050003.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050003.scexe"],"md5sum":"7ec9dbbf3af5e4e745559aac3f458642","name":"firmware-system-u61-1.54_2022_01_13-1.1.x86_64.rpm","release":"2022-01-17T06:35:33","revision":"0","sha1sum":"8253a67ff45dfef9a4180844cf156a2da5185c9f","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"e99fcbdfe7054c0191086c267b0b5462","version":"765403fce3aa4b58a1dae20b30a13a14"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML30 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T03:09:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U61","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB010000JWAYK and MB008000JWAYH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4210120","datemodified":"2021-07-23T11:31:27","file_list":["cp048672.xml","cpqsetup.exe","HLIBRHsseFD6.rel","payload.json","setup.dll"],"md5sum":"28ebbf4f18cae52ab28fe02e7269af80","name":"cp048672.exe","release":"2021-07-23T11:24:07","revision":"0","sha1sum":"92281966b0ac4f31c7db909ba5984a312b1a28e6","size":"4MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"e4254455513a49c0ad5f61c79ab13950","version":"e63c7e2329af4981a3dd741c7b6e7f21"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:29:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"10995845","datemodified":"2021-08-24T14:52:31","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/ice","./lib/modules/4.12.14-120-default/updates/ice/ice.ko","./usr/share/smartupdate/ice-kmp-default/component.xml"],"md5sum":"ee825b161de4095b16ad286bd174bc54","name":"ice-kmp-default-1.6.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-24T14:47:05","revision":"0","sha1sum":"ce712d63d853fb8bdbdc9caf80713def0959cb49","size":"10MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"type_of_change":"1","version":"1.6.4-1"}],"id":{"product":"02ba81d3bf8d40eb8d79abb45b24dbeb","version":"f6c0a6860b014b43bf91fa9b20393117"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel ice Drivers for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"ice-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11661824","datemodified":"2022-03-10T21:55:25","file_list":["cp051199.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_2.62_03_08_2022.signed.flash"],"md5sum":"70074314c970ca55bbc5aa4cbc6e53f4","name":"cp051199.exe","release":"2022-03-10T21:53:01","revision":"0","sha1sum":"239a10f1f010aa18a7d374a38bfe66213b69426c","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"ccbfcdbdc47644e7ab18a371d4af9d7a","version":"da3772600fd94b3c895343baeada9abb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:55:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Linux (x64) -&nbsp;HPE&nbsp;Smart Array P824i-p MR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0043(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</li>\n</ul>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名</strong><strong>：</strong><br />\n     オンラインROM Flashコンポーネントfor Linux (x64) - HPE SmartアレイP824i-p MR Gen10<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n    24.23.0-0043(A)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n    24.23.0-0042<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n    24.23.0-0042<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n    なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>Apollo 4510システムのサポートを追加しました</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>過熱の問題は、>=60Cしきい値のための誤ったIMLでした。新しいバージョンでしきい値を>65Cに変更しました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"6775825","datemodified":"2020-08-27T14:10:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/CP045234.xml","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/MR_FW_3324_4MB.rom.fw","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cafee9b6e4-24.23.0_0043-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045234.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045234.scexe"],"md5sum":"73a8ef7bb7e26e62eaaf7ed08d15bf68","name":"firmware-cafee9b6e4-24.23.0_0043-2.1.x86_64.rpm","release":"2020-08-27T13:55:04","revision":"0","sha1sum":"f0d968021872eefdc3970e344b3ceeb648e8b9c9","size":"6MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"1","version":"24.23.0-0043"}],"id":{"product":"e9e3449278f14c8cb84369f1b3996ad4","version":"b3774521b9e04341be6ae0de58dfc045"},"installation":{"command":"CP045234.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The actual name of the &#39;firmware-smartarray-cafee9b6e4-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute following commands:\n\t<ul>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the log file, located in the current directory</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-cafee9b6e4-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the log file, located in the&nbsp;current directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>'firmware-smartarray-cafee9b6e4-*'フォルダーの実際の名前は、最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドを実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*'ロケーションに<em>./setup</em> を追加してください。</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、現在のディレクトリにあるログファイルに保存されます</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-cafee9b6e4-*'ロケーションに移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-cafee9b6e4-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、現在のディレクトリにあるログファイルに保存されます</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-09-14T09:38:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00101958en_us\" style=\"color:#0563c1; text-decoration:underline\">a00101958en_us</a></p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3012584","datemodified":"2021-07-25T21:11:29","file_list":["4IYVHPG5.rel","cp048664.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"2d0bc3b289dc278d145b0b549659c144","name":"cp048664.exe","release":"2021-07-25T21:04:05","revision":"0","sha1sum":"ecd0b0a813ca490189748d9659fd0b9d3c3345f5","size":"2MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"01713b1febed4cc9a463023eeb2cf6ee","version":"ede24ea822904ca78180810df9309f40"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:02:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5 is the low level driver implementation for ConnectX-4, ConnectX-5 and ConnectX-6  Mellanox Ethernet Adapters on VMware ESXi 7.0 Update 2 and Update 3."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"916094","datemodified":"2021-12-09T13:37:38","file_list":["/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip","/cp050400.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/README.txt","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/release_note_nmlx5-core_4.21.71.101-1OEM.702.0.0.17630552.pdf","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/doc/release_note_nmlx5-rdma_4.21.71.101-1OEM.702.0.0.17630552.pdf","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vendor-index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.21.71.101-1OEM.702.0.0.17630552.vib","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.21.71.101-1OEM.702.0.0.17630552.vib","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vibs/nmlx5-rdma--2387361673357585997.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/vibs/nmlx5-core--2146088624239958034.xml","/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880-package.zip/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552_18117880.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.21.71.101-1OEM.702.0.0.17630552.xml"],"md5sum":"8cf8d3d940603354610c6021ca107fd3","name":"cp050400.zip","release":"2021-12-09T13:36:07","revision":"0","sha1sum":"cf213fcaa4faaef77ac3d3acf4efdab34e45f24b","size":"894KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec38df96d3"],"type_of_change":"1","version":"2021.04.21","vib_list":[{"name":"nmlx5-rdma","version":"4.21.71.101-1OEM.702.0.0.17630552"},{"name":"nmlx5-core","version":"4.21.71.101-1OEM.702.0.0.17630552"}]}],"id":{"product":"45e5e3b4b5524afa8388b9297cf98327","version":"fa3d68d275c244f78fda896bf20f554c"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx/を実行し、SUMを起動します（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）。</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"nmlx5_en Driver Component for VMware ESXi 7.0 Update 2 and Update 3"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T12:48:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features are included&nbsp;in smart component version 2021.04.21:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>vSan over RDMA.</li>\n\t\t<li>Receive Side Scaling (RSS) for ENS model 0.</li>\n\t\t<li>200GbE link speed.</li>\n\t\t<li>ConnectX-6 Lx devices.</li>\n\t\t<li>Scaled support for up to 10K connections over RDMA networks</li>\n\t\t<li>Data Center Bridging Capability Exchange (DCBX) protocol with hardware offload.</li>\n\t\t<li>sriov_mc_isolation module parameter to isolate multicast traffic to SR-IOV interfaces. Default value is OFF.</li>\n\t\t<li>ens_fallback_model to set the default fallback mode when the option to query ENS model from the OS is no supported. Default to Model 1.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>\n\t<p>SR-IOV InfiniBand is at GA level.</p>\n\t</li>\n\t<li>\n\t<p>Updated the supported_num_ports default value to 1 to lower memory constraints.<br />\n\tNote: The user must set a value corresponding to the amount of ports installed in the system.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>Fixed a compatibility issue with VMware Update Manager as it wouldn&#39;t accept a bundle with metadata xml with old versioning scheme. The metadata xml now contains the new versioning scheme.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features are included&nbsp;in smart component version 2021.04.21:</strong></p>\n\n<ul>\n\t<li>Added support for the following features:\n\t<ul>\n\t\t<li>vSan over RDMA.</li>\n\t\t<li>Receive Side Scaling (RSS) for ENS model 0.</li>\n\t\t<li>200GbE link speed.</li>\n\t\t<li>ConnectX-6 Lx devices.</li>\n\t\t<li>Scaled support for up to 10K connections over RDMA networks</li>\n\t\t<li>Data Center Bridging Capability Exchange (DCBX) protocol with hardware offload.</li>\n\t\t<li>sriov_mc_isolation module parameter to isolate multicast traffic to SR-IOV interfaces. Default value is OFF.</li>\n\t\t<li>ens_fallback_model to set the default fallback mode when the option to query ENS model from the OS is no supported. Default to Model 1.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>\n\t<p>SR-IOV InfiniBand is at GA level.</p>\n\t</li>\n\t<li>\n\t<p>Updated the supported_num_ports default value to 1 to lower memory constraints.<br />\n\tNote: The user must set a value corresponding to the amount of ports installed in the system.</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes&nbsp;included in version 4.21.71.101:</strong></p>\n\n<ul>\n\t<li>Fixed a compatibility issue with VMware Update Manager as it wouldn&#39;t accept a bundle with metadata xml with old versioning scheme. The metadata xml now contains the new versioning scheme.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx5-core:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Mellanox-nmlx5:4.21.71.101-1OEM.702.0.0.17630552","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"4120812","datemodified":"2021-12-20T08:38:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/CP050058.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050058.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050058.scexe"],"md5sum":"fd7d4ad4a9691769d5ebb9b25eb810a0","name":"firmware-d3000-5.04-4.1.x86_64.rpm","release":"2021-12-20T08:32:20","revision":"0","sha1sum":"0766799174d3a25d2fc1c41f52a0b109cb82145c","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"id":{"product":"d6810024a18142b0a4b8ec4db68a4e55","version":"a13fd2737f7e4d34a708fb102167a452"},"installation":{"command":"setup","command_params":"-t D3600 -t D3610 -t D3700 -t D3710 -v 5.04 -i Reveille-Release-5.04-build-000.bin -l D3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d3000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d3000-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created &nbsp;Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"Linux (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-24T08:54:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP3."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23141","datemodified":"2021-10-01T17:55:00","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"2fbc7af87b5874ca26328a222cd6c934","name":"libbnxt_re-219.0.8.0-sles15sp3.x86_64.rpm","release":"2021-10-01T17:49:57","revision":"0","sha1sum":"23b0ae0ec0d03954f270097a13fdb27fa8b94499","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"219.0.8.0"}],"id":{"product":"bb0c6fd1d6df4adcb15793f0346071ce","version":"2cc766c605f044dfa2183d7d09ae9a88"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP3"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-11-01T07:34:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB012000JWDFD Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4165944","datemodified":"2021-07-25T18:21:08","file_list":["cp048634.xml","cpqsetup.exe","HLEAHssseFD3.rel","payload.json","setup.dll"],"md5sum":"00eb7cb81a44dd53b8acff91e4db81fc","name":"cp048634.exe","release":"2021-07-25T18:14:04","revision":"0","sha1sum":"ede5a127b83922415ae448e74cd22096933cc01f","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"4893b899f6404bf4b119e3e3a55be5b2","version":"318609d8c34f4520b93eea3446f7aeb5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:50:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JFHMH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EG1800JFHMH Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"16246561","datemodified":"2021-08-31T06:44:16","file_list":["/CP048270_BUILD_2.data","/CP048270.vmexe","/CP048270.vmexe64","/CP048270.vmfile","/CP048270_VMw.zip","/CP048270.xml","/payload.json","/CP048270_VMw.zip/index.xml","/CP048270_VMw.zip/vendor-index.xml","/CP048270_VMw.zip/metadata.zip","/CP048270_VMw.zip/vib20/CP048270/HPE_bootbank_CP048270_HPD8.2-7.0.0.15843807.vib","/CP048270_VMw.zip/metadata.zip/vendor-index.xml","/CP048270_VMw.zip/metadata.zip/vmware.xml","/CP048270_VMw.zip/metadata.zip/vibs/CP048270--344626177108592925.xml","/CP048270_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048270_HPD8.2-7.0.0.15843807.xml"],"md5sum":"ef0cad3431e577720737c40e66a36201","name":"CP048270.zip","release":"2021-08-31T06:39:33","revision":"0","sha1sum":"5bf9b784b8abc5a644cae8057dfb430ecb37836d","size":"15MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP048270","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"b013dc662ea446dbabf5ade1d9cf8d6f","version":"37170fd2e4e84ddd94a64d5176b4718f"},"installation":{"command":"CP040626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T16:15:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16058131","datemodified":"2021-08-27T07:17:12","file_list":["/CP048393_BUILD_3.data","/CP048393.vmexe","/CP048393.vmexe64","/CP048393.vmfile","/CP048393_VMw.zip","/CP048393.xml","/payload.json","/CP048393_VMw.zip/index.xml","/CP048393_VMw.zip/vendor-index.xml","/CP048393_VMw.zip/metadata.zip","/CP048393_VMw.zip/vib20/CP048393/HPE_bootbank_CP048393_HPD5.3-7.0.0.15843807.vib","/CP048393_VMw.zip/metadata.zip/vendor-index.xml","/CP048393_VMw.zip/metadata.zip/vmware.xml","/CP048393_VMw.zip/metadata.zip/vibs/CP048393-6166442019455905043.xml","/CP048393_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048393_HPD5.3-7.0.0.15843807.xml"],"md5sum":"5aa23c206817f2113a253045602c64cf","name":"CP048393.zip","release":"2021-08-27T07:11:43","revision":"0","sha1sum":"7c8dd7aad41fa526dfd94a19a9ec92b27e8d5964","size":"15MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048393","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"1d291170bb0944cd8d58e9257151b0f1","version":"74a9c297c9d44c55bb89ae88f1a0763b"},"installation":{"command":"CP041422.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWU、およびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T12:15:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9092593","datemodified":"2021-08-12T02:05:19","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"1703eaf127d2379f14e466576bd3e4df","name":"kmod-netxtreme2_bl-7.14.80-5.rhel8u4.x86_64.rpm","release":"2021-08-12T01:43:06","revision":"0","sha1sum":"3e5663252085228a20c340ece6acd6f3d40e59e1","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"8936001","datemodified":"2021-08-12T02:09:49","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2_bl/component.xml"],"md5sum":"9004dde55758c2c8ab44f915e5df8be0","name":"kmod-netxtreme2_bl-7.14.80-5.rhel8u3.x86_64.rpm","release":"2021-08-12T01:43:06","revision":"0","sha1sum":"cc9e9f5ced21c45ea57141aff0ceefc9df36b3c2","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"b3f391bd1aa44685b17f74a3d4ddf32c","version":"33d71363769a4ee38d6f746498d85ac1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 4.</p>\n\n<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"72916","datemodified":"2022-01-25T13:36:30","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"9a251e683d2e128810edd863e16dbebb","name":"smartpqi-kmp-default-2.1.16-030.sles15sp3.x86_64.rpm","release":"2022-01-25T13:29:37","revision":"0","sha1sum":"82201b371589f023e44c78448ce0ec680867c802","size":"71KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.16-030"},{"bytes":"73021","datemodified":"2022-01-25T13:46:57","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"5e23821e98c57c1e2d190bdb051a667d","name":"smartpqi-kmp-default-2.1.16-030.sles15sp2.x86_64.rpm","release":"2022-01-25T13:29:37","revision":"0","sha1sum":"45115a41242eabfde1b8d432e802fadd5034dba0","size":"71KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.16-030"}],"id":{"product":"ddc8bdca3abc4ab8823e820be1ed4dfd","version":"f150d0c13e174064a4f28bc6d1552743"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles15&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)"},{"lang":"ja","x_late":"HPE ProLiant Gen10 Smartアレイコントローラー(64ビット)ドライバーfor SUSE LINUX Enterprise Server 15 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T15:44:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where duplicate device nodes for Ultrium tape drive and medium changer are being created.</li>\n\t<li>Fixed an issue where the OS boot could fail during logical volume rebuild.</li>\n\t<li>Fixed an issue to avoid failing IOs for devices which are offline.</li>\n\t<li>Fixed an issue where request_irq failed during system hibernation.</li>\n\t<li>Fixed take a long time to come up if the system is rebooted while a hard disk(s) is being sanitized on SLES15 SP2.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 8下で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"114156","datemodified":"2021-10-01T05:10:14","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/tg3","./lib/modules/4.18.0-305.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/3c394af8a1e0caea4f553bf7d61e0d96c3ce74","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"b9b1d43f0a7b9d748e10232ab03825c1","name":"kmod-tg3-3.139b-1.rhel8u4.x86_64.rpm","release":"2021-10-01T04:56:07","revision":"0","sha1sum":"c77f2033cb467b7af7e98494e21f505849227841","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"113690","datemodified":"2021-10-01T05:07:37","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3","./lib/modules/4.18.0-240.el8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/e2","./usr/lib/.build-id/e2/69ca287c5d716d66db896c0c546a2ca1380555","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"aa3ba3e8a65edc32d401995f596023d6","name":"kmod-tg3-3.139b-1.rhel8u3.x86_64.rpm","release":"2021-10-01T04:56:07","revision":"0","sha1sum":"e91c84854cf667c7481148b1b166392d726e0d35","size":"111KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"17ede1952e7d40da9d3235daae0363d6","version":"c8aab6886c654389a2bc7d0702ec83c1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</p>\n","latest_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18200032","datemodified":"2021-08-30T18:51:11","file_list":["/CP048300_BUILD_3.data","/CP048300.vmexe","/CP048300.vmexe64","/CP048300.vmfile","/CP048300_VMw.zip","/CP048300.xml","/payload.json","/CP048300_VMw.zip/index.xml","/CP048300_VMw.zip/vendor-index.xml","/CP048300_VMw.zip/metadata.zip","/CP048300_VMw.zip/vib20/CP048300/HPE_bootbank_CP048300_HPG6.3-7.0.0.15843807.vib","/CP048300_VMw.zip/metadata.zip/vendor-index.xml","/CP048300_VMw.zip/metadata.zip/vmware.xml","/CP048300_VMw.zip/metadata.zip/vibs/CP048300-2745758003451962957.xml","/CP048300_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048300_HPG6.3-7.0.0.15843807.xml"],"md5sum":"ffa7e69de8fba17bd5180f536a7a48a7","name":"CP048300.zip","release":"2021-08-30T18:46:14","revision":"0","sha1sum":"fb2ac808efd24d46ee538baf04bf4b2256450c80","size":"17MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6","vib_list":[{"name":"CP048300","version":"HPG6.3-7.0.0.15843807"}]}],"id":{"product":"fcc57b2588b04f54a01cb383a7a5a458","version":"a4094da3c41e485c97f5344adb7891d6"},"installation":{"command":"CP040784.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T10:00:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"16600108","languages":[{"lang":"fr","x_late":"Système d’exploitation - Améliorations"},{"lang":"en","x_late":"Operating System - Enhancements"},{"lang":"cn","x_late":"操作系统 - 增强功能"},{"lang":"tw","x_late":"作業系統 ─ 增強功能"},{"lang":"de","x_late":"Betriebssystem - Erweiterungen"},{"lang":"ko","x_late":"운영 체제 - 향상된 기능"},{"lang":"it","x_late":"Sistema operativo - Miglioramenti"},{"lang":"ja","x_late":"オペレーティング システム - 拡張"},{"lang":"es","x_late":"Sistema operativo - Mejoras"}]}],"description":[{"lang":"en","x_late":"This components installs the AMD PSHED service"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"609576","datemodified":"2021-11-26T08:13:51","file_list":["cp049984.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.sys"],"md5sum":"441427f281439c841c9b0b2d514de476","name":"cp049984.exe","release":"2021-11-26T08:12:13","revision":"0","sha1sum":"abf610087c7438a391928e8b47e7b7f929f79f21","size":"595KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"type_of_change":"1","version":"1.0.0.41"}],"id":{"product":"e485f42530b84989a3373bff82088143","version":"68086756fd844fbe851c61119d271fa0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"AMD PSHED Plug-in service for Microsoft Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-17T03:31:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"amdpshed.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"18034264","datemodified":"2021-11-30T06:32:04","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"0e0335ed99232e85b8a448546adf6b91","name":"kmod-qlgc-fastlinq-8.55.15.0-1.rhel8u4.x86_64.rpm","release":"2021-11-30T05:57:00","revision":"0","sha1sum":"b120effaa20c648106e4862c99e8179924bb6b9f","size":"17MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.55.15.0-1"},{"bytes":"20261806","datemodified":"2021-11-30T06:35:29","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.59.3.0.bin","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"ce6748fbcf759c80f06aa7b4df758a09","name":"kmod-qlgc-fastlinq-8.59.6.0-1.rhel8u5.x86_64.rpm","release":"2021-11-30T05:57:00","revision":"0","sha1sum":"f33f27664da6aade27ccabbf3e1389507cb04bcb","size":"19MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.55.15.0-1"}],"id":{"product":"fac6c21a4a1e47499a956ff93dccfbd6","version":"d7c6c0f2d94743b8abf9fc49e2bfdf00"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5474060","datemodified":"2021-07-23T07:47:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/CP048179.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/SAVGRTG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ec908c3650-HPG8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048179.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048179.scexe"],"md5sum":"eec3b569429e45085b77be9f0dbacc4d","name":"firmware-hdd-ec908c3650-HPG8-8.1.x86_64.rpm","release":"2021-07-23T07:35:06","revision":"0","sha1sum":"37d2baea6c1aaae91ae0c69b25d986517d843f4d","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"38437d438933420e8063d6e963ffd91f","version":"b8f0f4a7d0c04f97914b91d00f279aa7"},"installation":{"command":"CP040273.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:26:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7970708","datemodified":"2021-12-14T15:55:34","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"0b1b97fbcae4d0454bcbd5acfadbbfd9","name":"mft-4.18.0-106.sles15sp2.x86_64.rpm","release":"2021-12-14T15:38:04","revision":"0","sha1sum":"022366259c54873c55846e2a31695288c3cc8875","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.18"},{"bytes":"24023","datemodified":"2021-12-14T15:52:34","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/mst_pci.ko","./lib/modules/5.3.18-22-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"62b4eda49eedc0663705ac969f655673","name":"kernel-mft-mlnx-kmp-default-4.18.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-12-14T15:38:04","revision":"0","sha1sum":"4ba1f1074b462d428c36bed7f2e3189b5866185d","size":"23KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"type_of_change":"1","version":"4.18"}],"id":{"product":"d60ce0b82db54a2e881c0e0bf9e229a2","version":"d4864a99a4f6420caf79f9bba541aeec"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using 4.12.14-195-default kernel or any future errata:<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.18.0_k4.12.14_195-1.sles15sp2.x86_64.rpm&nbsp;&nbsp;mft-4.18.0-78.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"ac963eeb-ed78-4f36-8cc1-29d85f34a0ac","Devices":{"Device":[{"DeviceName":"Firmware for HPE 16GB NVDIMM DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp032704.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-80ad-80ad80ad80ad","Version":"1.04"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This Windows component provides firmware upgrade for HPE 16GB NVDIMM-N DDR4-2666 Modules."},{"lang":"ja","x_late":"このWindowsコンポーネントは、HPE 16GB NVDIMM-N DDR4-2666モジュール用のファームウェアアップデートを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Support list :</p>\n\n<p>Windows:</p>\n\n<ul>\n\t<li>Windows 2022</li>\n\t<li>Windows 2019</li>\n\t<li>Windows 2016</li>\n</ul>\n"}],"files":[{"bytes":"743808","datemodified":"2021-06-15T03:17:44","file_list":["cp032704.compsig","cp032704.zip","cp048495.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"7e3befabe4c78390922ab8f2959c3550","name":"cp048495.exe","release":"2021-06-15T03:16:06","revision":"0","sha1sum":"55e1d80ac7a8e8c54d3dc352cbfe4354fe2ab536","size":"726KB","target_guids":["805dd01c-eb5a-1e76-80ad-80ad80ad80ad"],"type_of_change":"0","version":"1.04"}],"id":{"product":"f164fee24b024bb9b6d0636563b8a349","version":"7d6a5740096d4e41a79c180f1b60b649"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant&nbsp;</a><strong>:</strong></strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.bat スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Microsoft Windows x64 - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T02:47:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>Initial relaese.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Add suppport for Microsoft Windows 2022</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1021416","datemodified":"2022-01-25T15:23:08","file_list":["cp049619.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"md5sum":"10107b6a3fc1bd30b210c843edc54c82","name":"cp049619.exe","release":"2022-01-25T15:09:18","revision":"0","sha1sum":"943ac1285293dfcc2e37e463021cb9d45dad0ee0","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"type_of_change":"1","version":"4.1.246.0"}],"id":{"product":"1607ed48320345de80b2a91bfe782685","version":"8d101909f353452c8af764f30a40fcc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixs.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4031920","datemodified":"2021-07-23T10:26:13","file_list":["cp048544.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"md5sum":"4a46117a43a7dc4d04d0a61e6b8aa0b4","name":"cp048544.exe","release":"2021-07-23T10:18:16","revision":"0","sha1sum":"cad4056c1bf0f36874627410ce13934455267c02","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"ed9a4b98eb61471ab66480b22d4e9c4f","version":"de6dfaa64e5340059e5e3bc9609569ca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:23:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000GEFQVおよびMM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;for:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3594040","datemodified":"2021-07-25T16:50:38","file_list":["cp048622.xml","cpqsetup.exe","payload.json","SAVGRTG8.rel","setup.dll"],"md5sum":"f7b018bcadaadf9a1bb1b42375c50c3b","name":"cp048622.exe","release":"2021-07-25T16:43:05","revision":"0","sha1sum":"3aea06c6bf6b4b7097f5dba02928c9a8aad1ef9b","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"54856ac460a544e2985eadac24abf907","version":"54dfbf8c90144a3490e2a1c7268c04f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:56:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JWXKH&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17635112","datemodified":"2021-08-27T18:26:43","file_list":["/CP049124_BUILD_1.data","/CP049124.vmexe","/CP049124.vmexe64","/CP049124.vmfile","/CP049124_VMw.zip","/CP049124.xml","/payload.json","/CP049124_VMw.zip/index.xml","/CP049124_VMw.zip/vendor-index.xml","/CP049124_VMw.zip/metadata.zip","/CP049124_VMw.zip/vib20/CP049124/HPE_bootbank_CP049124_HPD9.1-7.0.0.15843807.vib","/CP049124_VMw.zip/metadata.zip/vendor-index.xml","/CP049124_VMw.zip/metadata.zip/vmware.xml","/CP049124_VMw.zip/metadata.zip/vibs/CP049124--8377738557993626998.xml","/CP049124_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049124_HPD9.1-7.0.0.15843807.xml"],"md5sum":"0498e8d1e89fb7f644319d19f2a593d6","name":"CP049124.zip","release":"2021-08-27T18:22:03","revision":"0","sha1sum":"e51d03b3473ea90805b85fe9c9e0b65fbd349cef","size":"16MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049124","version":"HPD9.1-7.0.0.15843807"}]}],"id":{"product":"8a5f6b85a2a94dc58e5d42c516c7060a","version":"e72cd0a1a2554c49b874fb4c02d8a2cb"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:27:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware&nbsp;revision corrects a rare situation where a Cryptographic Erase could result in random data instead of the expected deterministic zeros. This is judged as low severity because it does not compromise user data or security, but justifies the update to preclude potential security concerns. There are several items that reduce the probability of hangs and provide some minor performance improvements.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6111137","datemodified":"2021-07-23T07:59:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/CP048098.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/HVLAnAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048098.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048098.scexe"],"md5sum":"c5cce600f3c6abda7e81c7f1edbad967","name":"firmware-hdd-ca21e169e2-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:47:13","revision":"0","sha1sum":"7fd2a6646c7906ee9d8784a89983bec4b1adb1fd","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"02a1f5d0f0e244c0b4c2ace636d0f60b","version":"140b27b6a05946a38b8401ec9fcfdc64"},"installation":{"command":"CP041494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000GWKGV ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:48:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62900","datemodified":"2021-03-08T18:23:57","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"f70dba16d37671f891799ab920187bd2","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"80f15d86f74ba0e3bb6ef72741c6d6f67be55769","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"62899","datemodified":"2021-03-08T18:19:39","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"3d079135a638cbf5dc430db567f12a96","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:13:04","revision":"0","sha1sum":"f7ce9704b8e9ac5f9334a529626e07f2e731678d","size":"61KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"5230830842514ef8a52b0b19a00fb203","version":"1fe9919da8234720accc28522b08cd41"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25011932","datemodified":"2021-08-30T07:26:07","file_list":["/CP049299_BUILD_1.data","/CP049299.vmexe","/CP049299.vmexe64","/CP049299.vmfile","/CP049299_VMw.zip","/CP049299.xml","/payload.json","/CP049299_VMw.zip/index.xml","/CP049299_VMw.zip/vendor-index.xml","/CP049299_VMw.zip/metadata.zip","/CP049299_VMw.zip/vib20/CP049299/HPE_bootbank_CP049299_HPG2.1-7.0.0.15843807.vib","/CP049299_VMw.zip/metadata.zip/vendor-index.xml","/CP049299_VMw.zip/metadata.zip/vmware.xml","/CP049299_VMw.zip/metadata.zip/vibs/CP049299-3653185010826679455.xml","/CP049299_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049299_HPG2.1-7.0.0.15843807.xml"],"md5sum":"fa4ebbc475d734290f39f59610594fa4","name":"CP049299.zip","release":"2021-08-30T07:21:38","revision":"0","sha1sum":"7708ed912554f775a45351a35fe6a9984421cbfc","size":"23MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP049299","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"a6c377914cad4568810f0a24fc0faa52","version":"542beb9061324c8ba9aa4cacc88ff4fd"},"installation":{"command":"CP043281.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWXFF、MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T10:41:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16803652","datemodified":"2022-01-17T06:39:11","file_list":["payload.json","U61_1.54_01_13_2022.signed.flash","U61_1.54_01_13_2022.xml"],"md5sum":"480c8d2292a24048337103570859b7a1","name":"U61_1.54_01_13_2022.fwpkg","release":"2022-01-17T06:35:18","revision":"0","sha1sum":"15537262eaca5ec02c589ee28ef9326eb7094d2d","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"a96fcafbb6d4411b8c5383684726a0e9","version":"39e4acda463e486f9dd59480f5eda907"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T03:49:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U61","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None.</p>\n"}],"files":[{"bytes":"3675016","datemodified":"2021-07-24T05:22:11","file_list":["cp048553.xml","cpqsetup.exe","HKFL4CD7.rel","payload.json","setup.dll"],"md5sum":"fcc0ef66fb07d449d47f5a327fe9b726","name":"cp048553.exe","release":"2021-07-24T05:14:04","revision":"0","sha1sum":"56c312cac2efc6e29b510e373441f2968f465362","size":"3MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"68a7de4833704c8fb3dbc75f2b162b30","version":"ddf8a1a086fc4d94876cddb46525ca00"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T04:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 8 x86_64."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7 Update 8 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25148","datemodified":"2021-10-01T18:19:43","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"b014337974e1f08fdd462f94f77a5ae3","name":"libbnxt_re-219.0.8.0-rhel7u8.x86_64.rpm","release":"2021-10-01T18:13:58","revision":"0","sha1sum":"80fe43ee4d85e6b8d9f07315dda413e1ca7dd72d","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"219.0.8.0"}],"id":{"product":"a7b0a77ad412478f9ceb945592e1c7ab","version":"f1dcb5df58434ccca4a24e9dae3c1fa9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">インボックスライブラリと競合する可能性のあるHPE Broadcom RoCEライブラリをインストールまたはアップデートするときは、--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 8"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 Update 8用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0118"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"36944461","datemodified":"2021-12-20T12:59:01","file_list":["/CP050051_BUILD_3.data","/CP050051.vmcfg","/CP050051.vmexe","/CP050051.vmexe64","/CP050051.vmfile","/CP050051_VMw.zip","/CP050051.xml","/payload.json","/CP050051_VMw.zip/index.xml","/CP050051_VMw.zip/vendor-index.xml","/CP050051_VMw.zip/metadata.zip","/CP050051_VMw.zip/vib20/CP050051/HPE_bootbank_CP050051_0118.3-7.0.0.15525992.vib","/CP050051_VMw.zip/metadata.zip/vendor-index.xml","/CP050051_VMw.zip/metadata.zip/vmware.xml","/CP050051_VMw.zip/metadata.zip/vibs/CP050051-4713461772257382902.xml","/CP050051_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050051_0118.3-7.0.0.15525992.xml"],"md5sum":"30e0389ed08f60a5f71622556417bb07","name":"CP050051.zip","release":"2021-12-20T12:55:38","revision":"0","sha1sum":"5b3e70bb6655af474a6870a1bef9e1a6fa282d11","size":"35MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0118","vib_list":[{"name":"CP050051","version":"0118.3-7.0.0.15525992"}]}],"id":{"product":"d65fb45f0327449eb7763d2d9cb7bf3e","version":"e3caaa9b962148e5a78d5429f8b47575"},"installation":{"command":"setup","command_params":"-t D8000 -v 0118 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff -l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"HPE D8000 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-23T08:04:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;.</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail.</p>\n\t</li>\n\t<li>\n\t<p>Fixes a problem where after upgrade, drives in slots 1 &ndash; 96 may not appear.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15 SP1."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 15 SP1下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22955","datemodified":"2021-02-11T00:35:40","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"995da5da2cbcef872a613c2ec8ce4b06","name":"libbnxt_re-218.0.7.0-sles15sp1.x86_64.rpm","release":"2021-02-11T00:33:04","revision":"0","sha1sum":"c3f3bb1743118affd235b1dc21b43ce120eed7b9","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"0edaaf6685e5406d9f15af585063acb1","version":"f52e007016ef420ab3f2755c688a470f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP1"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15 SP1用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now disables loading RoCE driver on VFs when Link Aggregation is enabled</li>\n\t<li>This product now supports rdma-core v22&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n\t<li>This product corrects an issue which HPSUM selects driver for SUSE Linux Enterprise Server 15 while SPP deployment running with SUSE Linux Enterprise Server 15 Service Pack 1 platform.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"},{"lang":"ja","x_late":"VMware vSphere 7.0ファイバーチャネルドライバーキットfor HPE Storage Emulexホストバスアダプター（HBA）"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"805123","datemodified":"2021-11-15T04:24:42","file_list":["/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip","/cp049966.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.13-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vibs/lpfc-3271848157575413779.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807.xml"],"md5sum":"741bab653a07e138d8920beb1bf0fd6a","name":"cp049966.zip","release":"2021-11-15T04:23:28","revision":"0","sha1sum":"3e8c6b051349607df587e37bcfe5030a72aeb331","size":"786KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7654434b","20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"lpfc","version":"12.8.528.13-1OEM.700.1.0.15843807"}]}],"id":{"product":"14bdb24247e844e783ad854d474aa245","version":"6575af0c623447278ab3c925a3e1be85"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE Storage Emulexファイバーチャネルドライバーコンポーネントfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.8.528.13</p>\n\n<p>This Driver is applicable on ESXi 7.0U2 only</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.13</p>\n\n<p>&nbsp;</p>\n\n<p>This component is supported only on ESXI 7.0U2</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"Broadcom-ELX-lpfc:12.8.528.13-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"lpfc:12.8.528.13-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6650079","datemodified":"2021-07-27T15:58:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/CP049158.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/M5300AG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f9bf23306-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049158.scexe"],"md5sum":"8fb9e1a512a5dcee7071689e9f8260df","name":"firmware-hdd-8f9bf23306-HPG1-2.1.x86_64.rpm","release":"2021-07-27T15:45:05","revision":"0","sha1sum":"4d1c48543a30aca6b84516048ffd1226d93de7ea","size":"6MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"49ef8a3b84714e97bc36564b7cd48c52","version":"35a6f51c6350416992e56924dcc78818"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl　\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:39:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JFJTH and MM002000JWCNF Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17286572","datemodified":"2021-08-27T07:07:56","file_list":["/CP048392_BUILD_2.data","/CP048392.vmexe","/CP048392.vmexe64","/CP048392.vmfile","/CP048392_VMw.zip","/CP048392.xml","/payload.json","/CP048392_VMw.zip/index.xml","/CP048392_VMw.zip/vendor-index.xml","/CP048392_VMw.zip/metadata.zip","/CP048392_VMw.zip/vib20/CP048392/HPE_bootbank_CP048392_HPD4.2-7.0.0.15843807.vib","/CP048392_VMw.zip/metadata.zip/vendor-index.xml","/CP048392_VMw.zip/metadata.zip/vmware.xml","/CP048392_VMw.zip/metadata.zip/vibs/CP048392--1101656020403834514.xml","/CP048392_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048392_HPD4.2-7.0.0.15843807.xml"],"md5sum":"6fee6ffa216cf974b8e35dc6f770a3e6","name":"CP048392.zip","release":"2021-08-27T07:02:18","revision":"0","sha1sum":"0489af9f7ccc59e2cc574ee081211463bdcf7cae","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048392","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"4aaa1b96312a4790820f2c40ac3eb0e7","version":"d35a2ba0f8c94671a10b0aa6f40500cf"},"installation":{"command":"CP040517.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T12:02:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_32_1010-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter "},{"lang":"ja","x_late":"HPE Ethernet 200Gb 1ポートQSFP56 MCX623105AS-VDATアダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter&nbsp;(P10180-B21)</td>\n\t\t\t<td>22.31.1014</td>\n\t\t\t<td>MT_0000000435</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 200Gb 1ポートQSFP56 MCX623105AS-VDATアダプター（P10180-B21）</td>\n\t\t\t<td>22.31.1014</td>\n\t\t\t<td>MT_0000000435</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"7006148","datemodified":"2021-12-07T09:33:00","file_list":["22_32_1010-MCX623105AS-VDA_Ax.pldm.signed","22_32_1010-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"md5sum":"731bc9870f6b0251bb43fa425e6407bf","name":"22_32_1010-MCX623105AS-VDA_Ax.pldm.fwpkg","release":"2021-12-07T09:30:04","revision":"0","sha1sum":"e6aa54a6472d547edc74a7ad1930b3e6075c1928","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"type_of_change":"1","version":"22.32.1010"}],"id":{"product":"f5b93810cc2347bb802707c26e414376","version":"eb7e02ef0ce04614b96a2d434161517d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter "},{"lang":"ja","x_late":"HPE Ethernet 200Gb 1ポートQSFP56 MCX623105AS-VDATアダプター用Mellanoxファームウェアパッケージ（FWPKG） "}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 22.31.1014:</strong></p>\n\n<ul>\n\t<li>Set the cap to 0 for high index functions to avoid too many parallel Virtual Function(VF) NODNIC functions.</li>\n\t<li>Implemented a new Network Communications Services Interface(NC-SI) command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Phy counters are cleared x seconds after link is up. This feature can be configured and enabled via the ini fields using the NVconfig.</li>\n\t<li>Extended the Dynamic Flex Parser capabilities in order to support Real-time Transport Protocol(RTP) packets parsing.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>NVME traffic can run now on another vHCA than the emulation manager vHCA.</li>\n\t<li>Allows the device to be configured with more than 256 MSIX vectors per physical PCI function.</li>\n\t<li>Enabled measuring PCIe eye dynamic grading over PCIe Gen3 speed.</li>\n\t<li>Enabled hardware real time clock for virtualized environment.</li>\n\t<li>Added support for the following:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>Matching field ipv4_ihl in create_flow_group and set_flow_table_entry commands.</li>\n\t\t<li>Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.</li>\n\t\t<li>A single Packet Filter(PF) per NUMA for Socket-Direct without a host management.</li>\n\t\t<li>Full tunnel header matcher to VXLAN header (including VXLAN alert bit).</li>\n\t\t<li>A new bit (&quot;data_in_order&quot;) to query the Queue Pair(QP) and allow a process/library to detect when the Adaptive Routing(AR) is enabled.</li>\n\t\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.31.1014:</strong></p>\n\n<ul>\n\t<li>A fatal assert (0x8274) occured due to invalid inputs sent to the query_vport_state command.</li>\n\t<li>Occasionally, toggling one of the NIC&#39;s port might result in link down of the 2nd port.</li>\n\t<li>Incorrect indication of the function dependency in the SR-IOV capability in PCIe configuration space.</li>\n\t<li>A rare issue that caused the destroy DCT command to not work properly when there were packet drops on connect packets in the network .</li>\n\t<li>The rate select mechanism in QSFP modules is fixed.</li>\n\t<li>A fatal error issue eventually causing the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number was overwritten with a 32 bit number and erased the high bits during de-allocation.</li>\n\t<li>Initialized the rate table in the static configuration so it would be configured at the link-not-up scenarios.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>The TX queue got into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>&quot;ICM-cache-large-scale&quot; steering mode was not supported with NoDNIC boot.</li>\n\t<li>Classification issues with &quot;Passive&quot; cables.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 22.32.1010:</strong></p>\n\n<ul>\n\t<li>Set the cap to 0 for high index functions to avoid too many parallel Virtual Function(VF) NODNIC functions.</li>\n\t<li>Implemented a new Network Communications Services Interface(NC-SI) command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Phy counters are cleared x seconds after link is up. This feature can be configured and enabled via the ini fields using the NVconfig.</li>\n\t<li>Extended the Dynamic Flex Parser capabilities in order to support Real-time Transport Protocol(RTP) packets parsing.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>NVME traffic can run now on another vHCA than the emulation manager vHCA.</li>\n\t<li>Allows the device to be configured with more than 256 MSIX vectors per physical PCI function.</li>\n\t<li>Enabled measuring PCIe eye dynamic grading over PCIe Gen3 speed.</li>\n\t<li>Enabled hardware real time clock for virtualized environment.</li>\n\t<li>Added support for the following:\n\t<ul>\n\t\t<li>Matching field ipv4_ihl in create_flow_group and set_flow_table_entry commands.</li>\n\t\t<li>Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.</li>\n\t\t<li>A single Packet Filter(PF) per NUMA for Socket-Direct without a host management.</li>\n\t\t<li>Full tunnel header matcher to VXLAN header (including VXLAN alert bit).</li>\n\t\t<li>A new bit (&quot;data_in_order&quot;) to query the Queue Pair(QP) and allow a process/library to detect when the Adaptive Routing(AR) is enabled.</li>\n\t\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.32.1010:</strong></p>\n\n<ul>\n\t<li>A fatal assert (0x8274) occured due to invalid inputs sent to the query_vport_state command.</li>\n\t<li>Occasionally, toggling one of the NIC&#39;s port might result in link down of the 2nd port.</li>\n\t<li>Incorrect indication of the function dependency in the SR-IOV capability in PCIe configuration space.</li>\n\t<li>A rare issue that caused the destroy DCT command to not work properly when there were packet drops on connect packets in the network .</li>\n\t<li>The rate select mechanism in QSFP modules is fixed.</li>\n\t<li>A fatal error issue eventually causing the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number was overwritten with a 32 bit number and erased the high bits during de-allocation.</li>\n\t<li>Initialized the rate table in the static configuration so it would be configured at the link-not-up scenarios.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>The TX queue got into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>&quot;ICM-cache-large-scale&quot; steering mode was not supported with NoDNIC boot.</li>\n\t<li>Classification issues with &quot;Passive&quot; cables.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under VMware vSphere vSphere 6.5."},{"lang":"ja","x_late":"このコンポーネントパッケージには、VMware vSphere vSphere 6.5で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.6.2.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.6.2.0が含まれています。</p>\n"}],"files":[{"bytes":"429049","datemodified":"2022-01-25T05:40:50","file_list":["/cp050786.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/index.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/vendor-index.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/metadata.zip","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/vib20/icen/INT_bootbank_icen_1.6.2.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-icen-1.6.2.0.xml","/VMW-ESX-6.5.0-icen-1.6.2.0-offline_bundle-18556790.zip/metadata.zip/vibs/icen-7422646159209865658.xml"],"md5sum":"1d44d6755d9e55e1abd09084c0ebcd7d","name":"cp050786.zip","release":"2022-01-25T05:40:39","revision":"0","sha1sum":"0a40cbb3f0707422f9ebaa3fda8ae17882999dc8","size":"418KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"icen","version":"1.6.2.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"c39088255d4c473a9f07d569516c5064","version":"9b037073bcb64b95a414207ad452aaa5"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"Intel icea ドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-14T02:22:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with&nbsp;<em>Intel Firmware Package For E810 Ethernet Adapter</em>&nbsp;(PLDM)&nbsp;&nbsp;version 3.10</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icen:1.6.2.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33595737","datemodified":"2022-02-21T05:32:34","file_list":["A42_2.56_02_10_2022.signed.flash","A42_2.56_02_10_2022.xml","payload.json"],"md5sum":"08044028158e86077c2ba5040a0c9631","name":"A42_2.56_02_10_2022.fwpkg","release":"2022-02-21T05:28:53","revision":"0","sha1sum":"956c4f84d9f778a0ce09fb708c87013a55c884f9","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"a745e380a94147888b60792dcbb594a8","version":"c94e4fa54dd54abbba1d3e2c4b71def2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"lang":"ja","x_late":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T07:32:18","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"26_32_1010-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE&nbsp;(P42044-B21)</td>\n\t\t\t<td>26.32.1010</td>\n\t\t\t<td>MT_0000000575</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6421861","datemodified":"2021-12-07T10:10:42","file_list":["26_32_1010-MCX631102AS-ADA_Ax.pldm.signed","26_32_1010-MCX631102AS-ADA_Ax.pldm.xml","payload.json"],"md5sum":"2815bd170fb7c8386e38acf4dbb1a3b4","name":"26_32_1010-MCX631102AS-ADA_Ax.pldm.fwpkg","release":"2021-12-07T10:07:05","revision":"0","sha1sum":"03fbd15222bdef2077b7a9ccd0f081bb355a57ea","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"type_of_change":"1","version":"26.32.1010"}],"id":{"product":"b50552ebf09d445294b0b81e162643cf","version":"ebbb54fa15024265bbb605d8f23b5d4f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New Features and Changes in Version 26.31.2006:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 26.31.2006:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n"},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 26.32.1010:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 26.32.1010:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX631102AS-ADAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16955271","datemodified":"2021-12-21T08:05:05","file_list":["/CP050140_BUILD_6.data","/CP050140.vmcfg","/CP050140.vmexe","/CP050140.vmexe64","/CP050140.vmfile","/CP050140_VMw.zip","/CP050140.xml","/payload.json","/CP050140_VMw.zip/index.xml","/CP050140_VMw.zip/vendor-index.xml","/CP050140_VMw.zip/metadata.zip","/CP050140_VMw.zip/vib20/CP050140/HPE_bootbank_CP050140_2.74.6-7.0.0.15525992.vib","/CP050140_VMw.zip/metadata.zip/vendor-index.xml","/CP050140_VMw.zip/metadata.zip/vmware.xml","/CP050140_VMw.zip/metadata.zip/vibs/CP050140--8102216228830708789.xml","/CP050140_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050140_2.74.6-7.0.0.15525992.xml"],"md5sum":"cfcb030f667d9b2161bf2b9e84d07135","name":"CP050140.zip","release":"2021-12-21T08:02:01","revision":"0","sha1sum":"109866853e621e2b7d4dde04008c999ab6d19123","size":"16MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74","vib_list":[{"name":"CP050140","version":"2.74.6-7.0.0.15525992"}]}],"id":{"product":"8bcfdc333663490ba14bb0a7e2286062","version":"2234d5e52dd44cbcbf41fa07a3613934"},"installation":{"command":"setup","command_params":"-t D6020 -v 2.74 -i Tormore-Release-2.74-build-001.bin -l D6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>VMWare Smart Component Installation Instructions:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Unzip the Smart Component with unzip CP0xxxxx.zip command.</li>\n\t<li>From the same directory, execute the Smart Component. For example: ./CP0xxxxx.vmexe.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p>OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;</p>\n\n<p><strong>Remote Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)"},{"lang":"ja","x_late":"HPE D6020 12Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor VMware (ESXi)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-29T12:22:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6399200","datemodified":"2021-11-18T06:55:11","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"42b0a566a846bebebec80404be8c9c18","name":"netxtreme2-kmp-default-7.15.02_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-11-18T06:35:56","revision":"0","sha1sum":"710d28b732a2d8d6bcce8042f78c59d1e4501726","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"1","version":"7.15.02-1"}],"id":{"product":"4cbf7b1f2fb64da880e8ed0ed8c83095","version":"158118af14af44a28617b8965a878316"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3040192","datemodified":"2021-07-24T07:27:25","file_list":["cp048459.xml","cpqsetup.exe","payload.json","setup.dll","T14SEhD4.rel"],"md5sum":"2a9409924850f918620758d1b1335d42","name":"cp048459.exe","release":"2021-07-24T07:20:09","revision":"0","sha1sum":"6a1593344f89003bee90cd3836deaee290dd9d5a","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"55c20afa55214e04bc6d7e8985b8d0b6","version":"90340bde05c44b01b89ae3c13d825d94"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWFVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T10:15:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB008000JWRTD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWRTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18520056","datemodified":"2021-08-30T20:29:14","file_list":["/CP048332_BUILD_2.data","/CP048332.vmexe","/CP048332.vmexe64","/CP048332.vmfile","/CP048332_VMw.zip","/CP048332.xml","/payload.json","/CP048332_VMw.zip/index.xml","/CP048332_VMw.zip/vendor-index.xml","/CP048332_VMw.zip/metadata.zip","/CP048332_VMw.zip/vib20/CP048332/HPE_bootbank_CP048332_HPD2.2-7.0.0.15843807.vib","/CP048332_VMw.zip/metadata.zip/vendor-index.xml","/CP048332_VMw.zip/metadata.zip/vmware.xml","/CP048332_VMw.zip/metadata.zip/vibs/CP048332-3419053399330638890.xml","/CP048332_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048332_HPD2.2-7.0.0.15843807.xml"],"md5sum":"dc0671bb2a404eb50f75a9ec5fc41af2","name":"CP048332.zip","release":"2021-08-30T20:24:06","revision":"0","sha1sum":"23f1a89122727b1c0788e0a308af57d5415ee87f","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57525444"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048332","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"a9e8e46bd6de460ea736a9be4499f26a","version":"1ae91753efa442e5b2359d160fded862"},"installation":{"command":"CP041478.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWRTD ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWRTD","target_guid":"4d2340a5-3042-3830-3030-304a57525444","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:04:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWRTD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2019を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1612176","datemodified":"2020-06-12T11:09:45","file_list":["bepnic.dll","bepnic.rtf","cp044542.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"3867a732a8f6d31de5b592929665fe50","name":"cp044542.exe","release":"2020-06-12T10:56:04","revision":"0","sha1sum":"2162bf360898c1fe98751a0362c0a1203bf04903","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"ee7c0fad5ff040dabc594be75871d841","version":"03f10bf622574025b711b1e94d94eee1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2876824","datemodified":"2021-07-25T12:15:08","file_list":["4IFDHPK4.rel","cp048476.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"91818df1d8d4b812bdb61ffd5debc898","name":"cp048476.exe","release":"2021-07-25T12:07:04","revision":"0","sha1sum":"d105164dbf9d52c2e476bf88136f6846aca58e1c","size":"2MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"e54bd80d86eb48638f965cd122dd00a1","version":"9a20a90746d5414c947982c634cce3ef"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows(x64)- VO0400KEFJB、VO1200KEFJC、およびVO2000KEFJDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:25:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD2"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD2"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD2"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD2"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD2"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD2"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD2"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD2"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD2"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD2"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD2"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64） - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ</p>\n\n<p><strong>リリースバージョンおよび/または日付：</strong><br />\n     HPD2<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     HPD1<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     HPD1<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"5610115","datemodified":"2021-12-09T07:48:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/CP050384.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/TAPM6ALLHPD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050384.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050384.scexe"],"md5sum":"30540d618f6f1757cefcc7dbdc8ee7fb","name":"firmware-hdd-42aff4675b-HPD2-1.1.x86_64.rpm","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"b051dd5951d3c2698ef50e2d2d429509f7332277","size":"5MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"74085bfad3ea4badb1e5c0235f47c1ea","version":"c7da2f0b30a94cc5875585939248616b"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T10:58:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GEXXV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16951870","datemodified":"2021-08-27T07:56:45","file_list":["/CP048403_BUILD_2.data","/CP048403.vmexe","/CP048403.vmexe64","/CP048403.vmfile","/CP048403_VMw.zip","/CP048403.xml","/payload.json","/CP048403_VMw.zip/index.xml","/CP048403_VMw.zip/vendor-index.xml","/CP048403_VMw.zip/metadata.zip","/CP048403_VMw.zip/vib20/CP048403/HPE_bootbank_CP048403_HPG2.2-7.0.0.15843807.vib","/CP048403_VMw.zip/metadata.zip/vendor-index.xml","/CP048403_VMw.zip/metadata.zip/vmware.xml","/CP048403_VMw.zip/metadata.zip/vibs/CP048403--6359453495002588922.xml","/CP048403_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048403_HPG2.2-7.0.0.15843807.xml"],"md5sum":"55a78858cb3604d4a79028d36844f863","name":"CP048403.zip","release":"2021-08-27T07:51:27","revision":"0","sha1sum":"1a38c3fcb0a2b657d11a80d4908bd7a6c4f5f238","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048403","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"b85e73b81c5b414ba6a301b86f35ed46","version":"05706743061244c19fe7d88347a53a4e"},"installation":{"command":"CP040515.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T21:27:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - &nbsp;MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16035363","datemodified":"2021-08-31T03:53:30","file_list":["/CP048489_BUILD_2.data","/CP048489.vmexe","/CP048489.vmexe64","/CP048489.vmfile","/CP048489_VMw.zip","/CP048489.xml","/payload.json","/CP048489_VMw.zip/index.xml","/CP048489_VMw.zip/vendor-index.xml","/CP048489_VMw.zip/metadata.zip","/CP048489_VMw.zip/vib20/CP048489/HPE_bootbank_CP048489_HPK4.2-7.0.0.15843807.vib","/CP048489_VMw.zip/metadata.zip/vendor-index.xml","/CP048489_VMw.zip/metadata.zip/vmware.xml","/CP048489_VMw.zip/metadata.zip/vibs/CP048489--2754645189579232014.xml","/CP048489_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048489_HPK4.2-7.0.0.15843807.xml"],"md5sum":"aaffa0714c4954094182dc1acae8c64e","name":"CP048489.zip","release":"2021-08-31T03:48:21","revision":"0","sha1sum":"5192088178cfda4605dd9f6127b528f6f993df5d","size":"15MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048489","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"199eba867d0c4e0892143a3378628d99","version":"b67745fe5bd84e1589d3811e6b312365"},"installation":{"command":"CP040195.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d /CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d /CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d /CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d /CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T12:04:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.27"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"本套件包含可升級 HPE ProLiant QLogic FastLinQ Gigabit 乙太網路網路卡 韌體的公用程式和二進位檔，適用於 Linux x86_64 平台。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE ProLiant QLogic FastLinQ 기가비트 이더넷 NIC 펌웨어를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"此软件包含有用于升级在Linux x86_64平台下运行的HPE ProLiant QLogic FastLinQ千兆以太网卡固件所需的实用程序和二进制文件。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v8.55.27. This combo image includes: Boot Code (MFW): 8.55.43.0, UEFI: 4.1.13.1&nbsp;and PXE: 2.0.19. The users will only see the combo image versions in the interactive mode firmware update or while using HPSUM/SPP to update the firmware on the supported adapters.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージには、コンボイメージv8.55.27が含まれています。このコンボイメージには以下が含まれます。ブートコード（MFW）：8.55.43.0、UEFI：4.1.13.1、PXE：2.0.19。ユーザーがコンボイメージのバージョンを確認できるのは、対話型モードのファームウェアアップデート、またはサポートされているアダプター上でHPSUM/SPPを使用してファームウェアをアップデートしている間だけです。</p>\n"}],"files":[{"bytes":"2247605","datemodified":"2022-02-07T10:19:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/CP050212.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/CP050212.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/nic_fw/ql_hp_ah_mbi_8.55.27.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.20.1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050212.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050212.scexe"],"md5sum":"fa02f5550525d5a47dbfa8582a4cb2e5","name":"firmware-nic-qlogic-flq-1.20.1-1.1.x86_64.rpm","release":"2022-02-07T10:11:57","revision":"0","sha1sum":"18ede68ca28804534db26087a22232b6c404f366","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"1.20.1"}],"id":{"product":"a2c850b33a31462c8693efedafbdd8b9","version":"66d93b4fa74d44f3b57c780abf49a391"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP048837.txt file.The results of the firmware upgrade are saved&nbsp;in CP048837.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n\t<li>Note that the firmware 8.35.43 enables additional network functionality on &#39;HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Converged Network Adapter&#39;. So once the adapter is updated to 8.35.43 or newer, it can no longer be downgraded to versions older than 8.35.43.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p>\n\n<ul>\n\t<li>ファームウェアrpmパッケージをインストールします。<br />\n\t<em>> rpm -ivh <rpm_filename>.rpm </em></li>\n\t<li>ファイルを抽出する場所を確認します。<br />\n\t<em>> rpm -qlp <rpm_filename>.rpm</em></li>\n\t<li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li>\n</ul>\n\n<p> </p>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<ul>\n\t<li>詳細情報はCP048837.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCP048837.logに保存されます。</li>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li>\n\t<li>ファームウェア8.35.43は、'HPE Ethernet 10/25Gb 2ポート622FLR-SFP28コンバージドネットワークアダプター'の追加のネットワーク機能を実現することに注意してください。したがって、アダプターを8.35.43またはそれ以降にアップデートすると、バージョン8.35.43よりも古いバージョンにダウングレードすることはできません。</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE QLogic FastLinQ 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE QLogic FastLinQ 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE QLogic FastLinQ 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-03T07:37:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the modification on string format of firmware update payload.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses the problem that the MAC being modified after Firmware update</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13157360","datemodified":"2021-08-20T08:30:14","file_list":["/CP046766_BUILD_11.data","/CP046766.vmexe","/CP046766.vmexe64","/CP046766.vmfile","/CP046766_VMw.zip","/CP046766.xml","/payload.json","/CP046766_VMw.zip/index.xml","/CP046766_VMw.zip/vendor-index.xml","/CP046766_VMw.zip/metadata.zip","/CP046766_VMw.zip/vib20/CP046766/HPE_bootbank_CP046766_2021.10.01.11-7.0.0.15843807.vib","/CP046766_VMw.zip/metadata.zip/vendor-index.xml","/CP046766_VMw.zip/metadata.zip/vmware.xml","/CP046766_VMw.zip/metadata.zip/vibs/CP046766-6319412335928090677.xml","/CP046766_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046766_2021.10.01.11-7.0.0.15843807.xml"],"md5sum":"df645349aa0c508192532a676f348626","name":"CP046766.zip","release":"2021-08-20T08:25:05","revision":"0","sha1sum":"8958ead65a7aa3fa82f3e57d930b6533a4822eef","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046766","version":"2021.10.01.11-7.0.0.15843807"}]}],"id":{"product":"798a64591d87417fba658ac00f3833b5","version":"71a233b6901c4123ac7593477f31cd34"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Fixed a behavior with internal engineering data display</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware version:</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:623px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Universal Boot Image</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot BIOS</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E Dual Port Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E-T Dual Port Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U61_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17424368","datemodified":"2022-01-17T06:36:36","file_list":["cp050009.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U61_1.54_01_13_2022.signed.flash"],"md5sum":"0593941a403f411828b0b28a863f5a30","name":"cp050009.exe","release":"2022-01-17T06:35:04","revision":"0","sha1sum":"b78355b391efae33f6f38c62fdebdf50658dfe4e","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023c"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"a6fc6d419cd14563aeefb1d3f50c589e","version":"6f25ed2907044c1490992f5b09c0fe4f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML30 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T04:03:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U61","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-514180897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-560580897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-001080897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-551580897a09","Version":"1.2.0.5446"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Linux Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers."},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のオンラインLinuxファームウェアコンポーネントを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"453942","datemodified":"2021-04-20T07:40:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/CP047626.xml","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/cp047625.compsig","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/cp047625.zip","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-1.2.0.5446-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047626.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047626.scexe"],"md5sum":"d5dafbd1b0e4f4332d18b51f8713b1b2","name":"firmware-dcpmm-1.2.0.5446-1.1.x86_64.rpm","release":"2021-04-20T07:33:22","revision":"0","sha1sum":"0cfe04dd74c14262f4c7457453237dceca65971c","size":"443KB","target_guids":["805dd01c-eb5a-1e76-8089-514180897a09","805dd01c-eb5a-1e76-8089-560580897a09","805dd01c-eb5a-1e76-8089-001080897a09","805dd01c-eb5a-1e76-8089-551580897a09"],"type_of_change":"1","version":"1.2.0.5446"}],"id":{"product":"005a4115369b4776b7144bbda87ad6ef","version":"d04f2e45daac482da45d8de957d70c2b"},"installation":{"command":"CP041747.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ol>\n\t<li>Install the firmware rpm using the command: rpm -ivh &lt;rpm_filename&gt;.&nbsp;</li>\n\t<li>This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location. After installation, navigate into this folder.</li>\n\t<li>The CPxxxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<br />\n\t<br />\n\t# <em>./CPxxxxxx.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)<br />\n\t<br />\n\t# <em>./hpsetup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location<br />\n\t&nbsp;</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ol>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ol>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ol>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use&nbsp;Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ol>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory,&nbsp;/SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow HPE Smart Update Manager steps to complete firmware update.</li>\n</ol>\n\n<p><strong>Online:</strong></p>\n\n<ol>\n\t<li>Login as root. (You must be root in order to apply the&nbsp;update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></p>\n\n<ol>\n\t<li>コマンド rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </li>\n\t<li>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。インストール後、このフォルダーに移動します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'firmware-dcpmem-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<br/>\n\t<br/>\n\t# <em>./CPxxxxxx.scexe</em> in the '/usr/lib/x86_64-linux-gnu/hp-scexe-compat' location (OR)<br/><br/># <em>./hpsetup</em> in the '/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*' location<br/>\n\t </li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ol>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ol>\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id.  これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-dcpmem-*'ロケーションに移動し、./hpsetupを実行してファームウェアをアップデートします。'firmware-dcpmem-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ol>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br/>\n<br />\n<strong>オフライン：</strong></p>\n\n<ol>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n</ol>\n\n<p><strong>オンライン：</strong></p>\n\n<ol>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネント for Linux - HPE Gen10サーバー上のIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-20T06:47:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</li>\n\t<li>This product contains mainly performance improvements.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 and SUSE Linux Enterprise Server 12.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB1000JVYZL, MB2000JVYZN, MB3000JVYZP&nbsp;and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17374458","datemodified":"2021-08-26T18:11:30","file_list":["/CP048344_BUILD_2.data","/CP048344.vmexe","/CP048344.vmexe64","/CP048344.vmfile","/CP048344_VMw.zip","/CP048344.xml","/payload.json","/CP048344_VMw.zip/index.xml","/CP048344_VMw.zip/vendor-index.xml","/CP048344_VMw.zip/metadata.zip","/CP048344_VMw.zip/vib20/CP048344/HPE_bootbank_CP048344_HPD3.2-7.0.0.15843807.vib","/CP048344_VMw.zip/metadata.zip/vendor-index.xml","/CP048344_VMw.zip/metadata.zip/vmware.xml","/CP048344_VMw.zip/metadata.zip/vibs/CP048344-2113967309781078438.xml","/CP048344_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048344_HPD3.2-7.0.0.15843807.xml"],"md5sum":"0ae824809c0d40185520f08a6a38b110","name":"CP048344.zip","release":"2021-08-26T18:05:43","revision":"0","sha1sum":"5ea5d8f80e8102c23347a74b56d5fd4ea85e1d85","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048344","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"9e4dc8db386245f0ad4fc38aef31f547","version":"e1d90af74488425ba62f9de6ecf09896"},"installation":{"command":"CP040660.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T16:16:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"362699","datemodified":"2020-06-11T04:18:54","file_list":["/cp044546.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"9b46aa68b1a2f32f667e21e0fc45326b","name":"cp044546.zip","release":"2020-06-11T04:18:10","revision":"0","sha1sum":"e9549e487bb930e39484ea94ccc9a7d88e830293","size":"354KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"c154697a46644c47b9724ee0f9b7eaa4","version":"2c8b05ea902743ac927a92c715bbd21a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1617576","datemodified":"2021-08-26T10:36:21","file_list":["cp046829.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"9457ffbc5360578c4da4f8462fc8ebb8","name":"cp046829.exe","release":"2021-08-26T10:33:10","revision":"0","sha1sum":"ddd79a604009fb288ca63a0f752f1fc3933049b7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"ad60a281882240318ac9ec3091a5f1c9","version":"b6ee1c82b6604fe780f8ca3cc1d3322a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to version 9.4.2.20</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where Hyper-V Virtual Machines (VMs) may not see all paths to Logical Unit Numbers (LUNs)</li>\n\t<li>Fixed a behavior where an Fibre Channel (FC) Tape device configured for Target Persistent Binding would not be recognized after server reboot</li>\n\t<li>Fixed a behavior where Multipath I/O (MPIO) paths may not recover if left offline for more than 90 seconds</li>\n\t<li>Fixed a behavior where Input/Output (I/O) incompletions would be reported after extended periods of uptime in an Fibre Channel (FC) fabric doing Remote Desktop Protocol (RDP) requests</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version 9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"MicroserverGen10PlusSPS_05.01.04.400.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8408101","datemodified":"2022-01-26T05:57:38","file_list":["MicroserverGen10PlusSPS_05.01.04.400.signed.bin","MicroserverGen10PlusSPS_05.01.04.400.xml","payload.json"],"md5sum":"ed9870fcfe6e6045bed408b446ee13bb","name":"MicroserverGen10PlusSPS_05.01.04.400.fwpkg","release":"2022-01-26T05:53:47","revision":"0","sha1sum":"1254e18aeac331062182d3e3f64bf316242150ca","size":"8MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"134da74460bf4b5aa8511e630ba5a272","version":"4f2b35a1811f47d5bccd7f4b42402c60"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:01:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 4ICSHPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 0px; margin-right: 0px;\">Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2832096","datemodified":"2021-07-24T10:18:01","file_list":["4ICSHPK4.rel","cp048692.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"d384a11a36a7f2a758435e17b42c09dc","name":"cp048692.exe","release":"2021-07-24T10:10:04","revision":"0","sha1sum":"6338186a73b1b907aad28c87899a5b0ac99b8cf7","size":"2MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4"}],"id":{"product":"142d96d331a04f9e847ceeb66ad042c6","version":"2342a80670484aba8e9a82749857a4d7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - ET000750KWJTF、EO000750KWTXCおよびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T11:19:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>\n\t<p>Fixed HPK3 drive reports incorrect Device ID issue.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5131302","datemodified":"2021-07-23T09:49:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/CP048213.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/G1633LD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2eb810cdd7-HPD8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048213.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048213.scexe"],"md5sum":"504bde4585a1011f00a4bb030ecf0a35","name":"firmware-hdd-2eb810cdd7-HPD8-4.1.x86_64.rpm","release":"2021-07-23T09:35:11","revision":"0","sha1sum":"e726fa0d592fbd59cb626084c028adf02c442a6a","size":"4MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"a27996e3432942ccb8c76d5fed9fc9b4","version":"78b8caa4c1c14411840275a9cfdbeb87"},"installation":{"command":"CP042627.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:17:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>TBD</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5324194","datemodified":"2021-08-26T07:12:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/CP049364.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/TARM5ALSHPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049364.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049364.scexe"],"md5sum":"8614365b35d30c90beb5a3a9de65d1cb","name":"firmware-hdd-8fafc9efb2-HPD6-1.1.x86_64.rpm","release":"2021-08-26T07:00:08","revision":"0","sha1sum":"7522d3ebae44b83e9f1c07ff77f3db6319ec7ce4","size":"5MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"9fd1abd8973f4c09aa450e541dc4ee41","version":"079a21793d7a4c4e95b1ac9602bbf164"},"installation":{"command":"CP041555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T06:55:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>TBD</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000300JWFVB&nbsp;Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4885942","datemodified":"2021-07-23T08:41:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/CP047501.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/T14SErD3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c5cd837c29-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047501.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047501.scexe"],"md5sum":"cfae76bfe2a9791db5017397d75cbc09","name":"firmware-hdd-c5cd837c29-HPD3-2.1.x86_64.rpm","release":"2021-07-23T08:29:06","revision":"0","sha1sum":"09ca7294526816d2c6038635df7ac4555f960853","size":"4MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"7163f5a35db04c1899f77a9e771fd83e","version":"bbe18fedac3f491a8faf79f113e76a6c"},"installation":{"command":"CP040323.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000300JWFVBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-09T09:05:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104367","datemodified":"2021-07-21T18:03:02","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"70267a3653e40d1087effc997f2ea5bb","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:48:19","revision":"0","sha1sum":"ce14a350232cc36fbd3af1bf2027421837ebdd6d","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104283","datemodified":"2021-07-21T18:00:25","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"517ba511ee3fc595ea39031c2331c589","name":"kmod-be2net_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-07-21T17:48:19","revision":"0","sha1sum":"32cff5b2a8e726c5b6fbe4e39810dacbb12544f6","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"37f4d88a2594441eb8937501d8ada85b","version":"cf64c54c80fa412ba3f6336bb3b25373"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 7.0."},{"lang":"ja","x_late":"この製品は、VMware vSphere 7.0下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;219.0.17.0 and RoCE driver version&nbsp;219.0.4.0.</p>\n"}],"files":[{"bytes":"400818","datemodified":"2021-09-28T12:21:56","file_list":["/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip","/cp047900.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_219.0.13.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_219.0.29.0-1OEM.700.1.0.15843807.vib","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip/vibs/bnxtroce-7844241372122612301.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip/vibs/bnxtnet-4380260230371990333.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807_18660116.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.700.1.0.15843807.xml"],"md5sum":"1363dc21675909f512dbe9229ca78314","name":"cp047900.zip","release":"2021-09-28T12:17:47","revision":"0","sha1sum":"18f0c48e74e323e4a34e9429538407c1de3f5a92","size":"391KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"bnxtroce","version":"219.0.13.0-1OEM.700.1.0.15843807"},{"name":"bnxtnet","version":"219.0.29.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"11a6992c4ec7430e9b4f2b44f5d06fe1","version":"56593fe647b04c7db81329fafad180b9"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances that new query for Firmware health data.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:219.0.29.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:219.0.13.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-bnxt-Net-RoCE:219.0.235.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"16900659","datemodified":"2021-09-10T09:30:08","file_list":["/CP049505_BUILD_1.data","/CP049505.vmexe","/CP049505.vmexe64","/CP049505.vmfile","/CP049505_VMw.zip","/CP049505.xml","/payload.json","/CP049505_VMw.zip/index.xml","/CP049505_VMw.zip/vendor-index.xml","/CP049505_VMw.zip/metadata.zip","/CP049505_VMw.zip/vib20/CP049505/HPE_bootbank_CP049505_0.39.1-7.0.0.15843807.vib","/CP049505_VMw.zip/metadata.zip/vendor-index.xml","/CP049505_VMw.zip/metadata.zip/vmware.xml","/CP049505_VMw.zip/metadata.zip/vibs/CP049505-2605781942637966724.xml","/CP049505_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049505_0.39.1-7.0.0.15843807.xml"],"md5sum":"352d537b5c51e6b22de15046d6d18ac3","name":"CP049505.zip","release":"2021-09-10T09:10:52","revision":"0","sha1sum":"a0090fa3cca6794234e5ba1c23feab7b96490de2","size":"16MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39","vib_list":[{"name":"CP049505","version":"0.39.1-7.0.0.15843807"}]}],"id":{"product":"a271f679286141d98830336f93a8205f","version":"1d9889cfa4b14e909b813b96099e0352"},"installation":{"command":"CP049505.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HP Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HP Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, for the firmware update to take effect</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加します。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします</li>\n\t<li>SUMを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します</li>\n\t<li><strong>SUM 6.0以降の場合は、</strong>ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Manager Steps の指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HP Insight Control for vCenterを使用するには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HP Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-09T16:27:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Product ID&#39;s to &quot;A4200 Gen10P LFF&quot; and &quot;A4200 Gen10P SFF&quot; to distinguish the generation.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"A4200 Gen10P SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"A4200 Gen10P LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3341296","datemodified":"2021-07-25T17:59:50","file_list":["cp048630.xml","cpqsetup.exe","HSSCPCD3.rel","payload.json","setup.dll"],"md5sum":"7fd06f958b1c94b1731b52f51a8286d0","name":"cp048630.exe","release":"2021-07-25T17:52:05","revision":"0","sha1sum":"476838d0cd4ef35721ba608f42a6b3bacaa05b39","size":"3MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c9d950d613945119a93065a8b8651f2","version":"8de63901a764465b9db3e7e99fd8f5ad"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:18:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 MCX653435A-HDAI OCP3 PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 MCX653435A-HDAI OCP3 PCIe4 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16&nbsp; OCP3 MCX653435A-HDAI Adapter(P31323-B21)</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000592</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 PCIe4 x16 OCP3 MCX653435A-HDAIアダプター（P31323-B21）</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000592</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"5952573","datemodified":"2021-12-07T10:00:11","file_list":["20_32_1010-MCX653435A-HDA_HPE_Ax.pldm.signed","20_32_1010-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"98c13089824d3145b2738fa9fd239959","name":"20_32_1010-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:57:19","revision":"0","sha1sum":"89f6ce235b578b58517591fa6af1e9fc3682d2b2","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900347"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"e6fc00ad6a3e4c539778e7419a9fafa6","version":"b98623effda245fba3db4a96c8fa34c8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 MCX653435A-HDAI OCP3 PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 1ポートQSFP56 MCX653435A-HDAI OCP3 PCIe4 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the HPE Blade QLogic userspace IO daemon that provides ARP/DHCP support for iSCSI offload for Blade QLogic NX2 Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15 SP1."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15 SP1で動作するBlade QLogicマルチファンクションGigabit Ethernet NICのiSCSIオフロード用のARP/DHCPサポートを提供するHPE Blade QLogic userspace IO Daemonが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"99628","datemodified":"2020-02-12T18:46:21","file_list":["./etc/logrotate.d/iscsiuiolog","./sbin/iscsiuio","./usr/lib/.build-id","./usr/lib/.build-id/85","./usr/lib/.build-id/85/c3cfa1e86cfabbf8aae2b9075be2b98b9f29d2","./usr/share/man/man8/iscsiuio.8.gz","./usr/share/smartupdate/iscsiuio_bl/component.xml"],"md5sum":"fd97603fda31237994a666c33ef170e6","name":"iscsiuio_bl-2.11.5.13-3.sles15sp1.x86_64.rpm","release":"2020-02-12T18:45:06","revision":"0","sha1sum":"a46e773cf9f039fd6a4e42a1cae2dcdd489dc6fc","size":"97KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf9413ac8"],"type_of_change":"0","version":"2.11.5.13-3"}],"id":{"product":"48c9c127d8e84c96aa3d591f450ace21","version":"556182e6fc1246258154795ae211f65c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 iSCSI Offload IO Daemon for SUSE Linux Enterprise Server 15 SP1"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product has&nbsp;been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"iscsiuio_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"820348","datemodified":"2021-08-26T10:52:28","file_list":["/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip","/cp046819.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/Readme-ESX70.qlnativefc","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/Release-ESX70-4.1.34.0.qlnativefc","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/README.txt","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_4.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vibs/qlnativefc-847282033782445070.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/bulletins/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807.xml"],"md5sum":"ed88cba6d311ef9c6edd25b2ee70dfa0","name":"cp046819.zip","release":"2021-08-26T10:51:05","revision":"0","sha1sum":"56b2e99955b08d4138db079931d97be30802da4e","size":"801KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"4.1.34.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"c07f99c2b0d248348543770e8f33efd1","version":"9cbc793baa514adc865bfbc865b151dc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:51:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Driver version 4.1.22.0</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where enabling VM-ID and SmartSAN on a boot from Storage Area Network (SAN) setup caused driver load incomplete</li>\n\t<li>Fixed a behavior where automatic attempts to recover from the behavior described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a> would result in a Purple Screen of Death (PSoD)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 4.1.34.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:4.1.34.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-QLogic-FC:4.1.34.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.00"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"5.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Supplemental Update / Online ROM Flash Component for Linux&nbsp;(x64)&nbsp;- HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3.21<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Enhanced the performance of sequential READ I/Os greater than 256KiB for cached logical drives.</li>\n\t<li>Added support for user-configurable expander scan duration parameters.</li>\n\t<li>Improved background consistency check to scan logical drives more eff iciently.</li>\n\t<li>Added support for Port Discovery Protocol host tool option to support SGPIO or UBM backplanes.</li>\n\t<li>Improved handling of reserved SMBUS addresses.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     サプリメンタルアップデート/オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE SmartアレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a<br />\n<br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n     3.21<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     3.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     なし</p>\n\n<p><strong>ファームウェアの関連性:</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>キャッシュされた論理ドライブの256KiBを超える順次読み取りI/Oのパフォーマンスが向上しました。</li>\n\t<li>ユーザーが構成可能なエキスパンダースキャン継続時間パラメーターのサポートが追加されました。</li>\n\t<li>バックグラウンド整合性チェックが改善され、論理ドライブのスキャン効率が向上しました。</li>\n\t<li>SGPIOまたはUBMバックプレーンをサポートするためのPort Discovery Protocolホストツールオプションのサポートが追加されました。</li>\n\t<li>予約済みSMBUSアドレスの処理を改善しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong>     </p>\n\n<p>     なし</p>\n\n<p><strong>既知の問題点:</strong><br />\n     なし</p>\n\n<p> </p>\n"}],"files":[{"bytes":"8812345","datemodified":"2022-01-21T18:37:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/CP049388.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/HPE_luxor.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049388.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049388.scexe"],"md5sum":"a4614ad7cd707de543aa4b62276ad598","name":"firmware-smartarray-f7c07bdbbd-5.00-1.1.x86_64.rpm","release":"2022-01-21T18:21:30","revision":"0","sha1sum":"f29a6a967189c77fe926133d2e600fe4e8e29ae9","size":"8MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"5.00"}],"id":{"product":"02754226ca24415fbdc877dfe47af242","version":"a06269a339da44ada286007600933c0a"},"installation":{"command":"CP049388.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP043010.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP043010.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f7c07bdbbd-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP043010.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./ CP043010.scexe in the '/usr/lib/x86_64-linux-gnu/scexe-compat' location （または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f7c07bdbbd-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Smart アレイP408i-p、P408e-p、P408i-a、E208i-p、E208e-p、E208i-a、P816i-a SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T16:05:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where SSD SmartPath is not enabled on logical drives created on the same array in certain scenarios.</li>\n\t<li>Fixed a problem where WRITE and READ fails with URE on a RAID6 volume where it could have completed successfully in certain error recovery scenarios.</li>\n\t<li>Fixed a problem where events were not getting logged in certain scenarios.</li>\n\t<li>Fixed an issue where a Windows memory dump process was taking longer than 30 minutes.</li>\n\t<li>Fixed a problem in Gen10+ server where FAULT LED was not turning on for the drives failing during device discovery.</li>\n\t<li>Fixed a problem where the critical event &quot;Controller memory ECC error limit exceeded&quot; was reported in the AHS IML log after upgrading to 3.53 B0 firmware build.</li>\n\t<li>Fixed a problem where the host WRITE I/O failed on the SmartCache logical drive with UREs present on the primary logical drive.</li>\n\t<li>Fixed an issue where the controller may be non-responsive after drive failure with SSD SmartPath enabled under a high queue depth workload.</li>\n\t<li>Fixed a performance issue when the host is submitting large sequential IO streams at high queue depth.</li>\n\t<li>Fixed an issue where OS filesystem is not available after making configuration changes in HII.</li>\n\t<li>Fixed an issue where error was observed while selecting edit SmartCache Logical drive option when SmartCache logical drive is in Degraded mode.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64)&nbsp;- MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3132624","datemodified":"2021-07-25T18:00:29","file_list":["cp048632.xml","cpqsetup.exe","M5100MGG.rel","payload.json","setup.dll"],"md5sum":"dee77b944c43493e9c0e3530c47dd4c8","name":"cp048632.exe","release":"2021-07-25T17:53:04","revision":"0","sha1sum":"f92a635eb348705fb31095ead9b1952dce622f0b","size":"2MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"acb1ff6d668a45ae89fbb3be24e50b7f","version":"a7efc55b6b4d45edb726f1045fbb160b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB、およびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:34:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1309552","datemodified":"2021-08-12T05:37:51","file_list":["cp048047.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"1b3391d738ca28e41652ef36dab26d20","name":"cp048047.exe","release":"2021-08-12T05:22:27","revision":"0","sha1sum":"d07772d800bdc48380940cce19816808bf5029dd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"683278c3722a411eb75e30e9eb4f543d","version":"ba87b32be2c9494cb63910903bf4a778"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel iavf Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1889","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-188980860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1889","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>​Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE</li>\n\t<li>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"iavf68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1564672","datemodified":"2021-08-18T02:54:02","file_list":["cp048045.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"2d7ba8b2c16bb9eeeff29a452526b6bd","name":"cp048045.exe","release":"2021-08-18T02:40:08","revision":"0","sha1sum":"45ec45123712bbb339db942095ba0f53e67d6ea2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"type_of_change":"0","version":"1.9.65.0"}],"id":{"product":"5e67b3914b754070a44558f816a7dbab","version":"afbe71837347464c8346a89c66215c8c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>​Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE</li>\n\t<li>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16802488","datemodified":"2022-02-21T02:02:24","file_list":["IEGen10_0.2.3.0.signed.bin","IEGen10_0.2.3.0.xml","IEGen10_0.2.3.0_B.signed.bin","payload.json"],"md5sum":"5cf91306700e2cedda419aa6a599b354","name":"IEGen10_0.2.3.0.fwpkg","release":"2022-02-21T01:58:19","revision":"0","sha1sum":"f2e271b0ae9bc8e3e6aad3b491adafc9c044fed3","size":"16MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.3.0"}],"id":{"product":"91adee7c0766499184ce8d25a925669e","version":"65a53e381e954b2e80987b720e9e240c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-21T01:55:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Address an issue where Innovation Engine (IE) Firmware may be unresponsive and iLO Firmware may report &ldquo;Update Failed&rdquo; after flashing the Innovation Engine (IE) Firmware via RESTful update. &nbsp;The flash will have been performed successfully, but the system must be reset for IE Firmware to function properly.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"14885117","datemodified":"2021-11-30T06:25:46","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.3.18-22-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"409e50c3fc5536f37728f7502b383b6e","name":"qlgc-fastlinq-kmp-default-8.55.15.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-11-30T06:02:53","revision":"0","sha1sum":"08e079a1a7f131bd3357c681ff6f331e93e53390","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"1","version":"8.55.15.0-1"},{"bytes":"15320635","datemodified":"2021-11-30T06:30:37","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/5.3.18-57-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"5c22cc6cc4833a17e8287b24de90d15e","name":"qlgc-fastlinq-kmp-default-8.55.15.0_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-11-30T06:02:53","revision":"0","sha1sum":"e296862e18fa99998c3cf72faa84ed51661cbf06","size":"14MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"1","version":"8.55.15.0-1"}],"id":{"product":"39b3bcd8f8b243ad9879002d6ba846cc","version":"dbcc9cf020d4481ca7fc3eb1987d0b98"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3658616","datemodified":"2021-07-25T20:42:09","file_list":["cp048652.xml","cpqsetup.exe","payload.json","SCIMARRNNTG3.rel","setup.dll"],"md5sum":"bb1a9c5a3f120629351410e274c96643","name":"cp048652.exe","release":"2021-07-25T20:35:10","revision":"0","sha1sum":"9e659c906e53193ae1305a3e99ceae1581eecf1b","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"260b73b77b824e60a7231a400ce24c25","version":"f9ecd669500a4bb386cf0a61bf546cd9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:54:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"16_32_1010-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX562A-ACAI OCP3アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter(P10112-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000241</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5557656","datemodified":"2022-01-06T19:30:04","file_list":["16_32_1010-MCX562A-ACA_Ax_Bx.pldm.signed","16_32_1010-MCX562A-ACA_Ax_Bx.pldm.xml","payload.json"],"md5sum":"e34415024f4904e24f1be1f7f8d562ae","name":"16_32_1010-MCX562A-ACA_Ax_Bx.pldm.fwpkg","release":"2022-01-06T19:25:18","revision":"0","sha1sum":"d146044f4c3a3939a716777b56d08807237fe1eb","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101715b30052"],"type_of_change":"1","version":"16.32.1010"}],"id":{"product":"a6a815c1e19641d7b77e2e862e63ca3a","version":"7dfd621739d94147bf532d5798e0f1d8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10/25Gb 2ポートSFP28 MCX562A-ACAI OCP3アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-06T05:10:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features included in Firmware version 16.31.2006:</strong></p>\n\n<ul>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF.\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>To enable it:</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p style=\"margin-left:96px\">PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF must be set to a none zero value.</p>\n\n<ul>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes included in firmware version 16.31.2006:</strong></p>\n\n<ul>\n\t<li>Altered the GetInventory NC-SI command to not report leading 0xf in firmware version when it starts with 0.</li>\n\t<li>Fixed PCIe lane margining capability issues.</li>\n\t<li>Fixed an issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"<p><strong>New Features and Changes included in Version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig&nbsp;sets the port to work in AN mode and sets the module to No Data Management Engine (DME). This change&nbsp;does not affect the speed logic, only the forward error correction (FEC) logic (FEC override).</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>Additional Fixes included in version 16.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX562A-ACAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2051720","datemodified":"2021-08-27T06:43:15","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp046770.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"d41e3321d59ce228c8392fd04379c82a","name":"cp046770.exe","release":"2021-08-27T06:39:06","revision":"0","sha1sum":"430215d94fa6fc0f40fe02ce32f4ae1ec7c6e81f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"a1ae47134c0e4b378bbf0bb2397b9e93","version":"e981c4b3e5564f6fa07e9d1258b0ddfc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p> </p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2012R2"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"9093942","datemodified":"2021-11-18T07:12:28","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"0343d40c7545e969997e323dab4a818c","name":"kmod-netxtreme2-7.15.02-1.rhel8u4.x86_64.rpm","release":"2021-11-18T06:47:55","revision":"0","sha1sum":"8f3f9f7856bf4895d3139f3514932b92443911da","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.02-1"},{"bytes":"9400081","datemodified":"2021-11-18T07:15:25","file_list":["./etc/depmod.d/netxtreme2.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"md5sum":"f9546cfbf3f13343815d431628ae6803","name":"kmod-netxtreme2-7.15.03-2.rhel8u5.x86_64.rpm","release":"2021-11-18T06:47:55","revision":"0","sha1sum":"276061b8d6939a4aac668a837db7be88919d9535","size":"8MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"type_of_change":"1","version":"7.15.02-1"}],"id":{"product":"9f8f92dcaee7444992d11c0fa284d349","version":"65ac858dd68446f3b473067b8f444171"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 4</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"},{"name":"kmod-netxtreme2","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GEQUT and MB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17559937","datemodified":"2021-08-26T20:31:26","file_list":["/CP048371_BUILD_2.data","/CP048371.vmexe","/CP048371.vmexe64","/CP048371.vmfile","/CP048371_VMw.zip","/CP048371.xml","/payload.json","/CP048371_VMw.zip/index.xml","/CP048371_VMw.zip/vendor-index.xml","/CP048371_VMw.zip/metadata.zip","/CP048371_VMw.zip/vib20/CP048371/HPE_bootbank_CP048371_HPGB.2-7.0.0.15843807.vib","/CP048371_VMw.zip/metadata.zip/vendor-index.xml","/CP048371_VMw.zip/metadata.zip/vmware.xml","/CP048371_VMw.zip/metadata.zip/vibs/CP048371--6397431421621867534.xml","/CP048371_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048371_HPGB.2-7.0.0.15843807.xml"],"md5sum":"92e383ad30c7cb975095f024881cb734","name":"CP048371.zip","release":"2021-08-26T20:26:08","revision":"0","sha1sum":"19ee148fd3af5685f4f6298ee68aef35aca10775","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP048371","version":"HPGB.2-7.0.0.15843807"}]}],"id":{"product":"ef9e3c99746c4ae380ca5d0cac6d2b97","version":"b90cbdbf0f224b70a65964f41155a0c1"},"installation":{"command":"CP040632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"},{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T21:10:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK75H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7693496","datemodified":"2021-07-24T08:54:23","file_list":["cp048464.xml","cpqsetup.exe","MPK75H5Q.rel","payload.json","setup.dll"],"md5sum":"981549506c99edef2b742d1928260142","name":"cp048464.exe","release":"2021-07-24T08:47:05","revision":"0","sha1sum":"456cdb2a9d8f0c2b502d38a820d8b0e72cebf068","size":"7MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"2","version":"MPK75H5Q"}],"id":{"product":"459b31cbafbe408eaf0a96421248c984","version":"d1e0b3d3b2eb4b00a174b1c57df26e3a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-0ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T12:17:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33596925","datemodified":"2022-02-21T05:33:33","file_list":["A43_2.56_02_10_2022.signed.flash","A43_2.56_02_10_2022.xml","payload.json"],"md5sum":"fedf5469f15b915c43495f7d9aa0da9d","name":"A43_2.56_02_10_2022.fwpkg","release":"2022-02-21T05:29:50","revision":"0","sha1sum":"42dc87613da4a1f34d9db95db802068134696546","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"bafc8d47aead420a9621e8d49861aa9b","version":"958416c45db64b92bbca9b3a5a972e4a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"lang":"ja","x_late":"ROMフラッシュユニバーサルファームウェアパッケージ - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T06:05:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG2"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNETG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000GWWQU and MB006000GWWQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17721440","datemodified":"2021-08-27T11:36:40","file_list":["/CP048425_BUILD_2.data","/CP048425.vmexe","/CP048425.vmexe64","/CP048425.vmfile","/CP048425_VMw.zip","/CP048425.xml","/payload.json","/CP048425_VMw.zip/index.xml","/CP048425_VMw.zip/vendor-index.xml","/CP048425_VMw.zip/metadata.zip","/CP048425_VMw.zip/vib20/CP048425/HPE_bootbank_CP048425_HPG2.2-7.0.0.15843807.vib","/CP048425_VMw.zip/metadata.zip/vendor-index.xml","/CP048425_VMw.zip/metadata.zip/vmware.xml","/CP048425_VMw.zip/metadata.zip/vibs/CP048425--1460648084595783290.xml","/CP048425_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048425_HPG2.2-7.0.0.15843807.xml"],"md5sum":"2ec8694949f8fc94a06dad74805d33b5","name":"CP048425.zip","release":"2021-08-27T11:31:31","revision":"0","sha1sum":"9739f463ff88f79a6e685c6cb4ae52440e067716","size":"16MB","target_guids":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048425","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"fbe68804b30c4fe28e13ea472cae5392","version":"cbd2d9f88684491a891cd46743d69688"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000GWWQUおよびMB006000GWWQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWWQU","target_guid":"4d2340a5-3042-3830-3030-304757575155","type":"sata"},{"id":"MB006000GWWQT","target_guid":"4d2340a5-3042-3630-3030-304757575154","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T06:00:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWWQT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWWQU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5_en Ethernet driver (ConnectX-4, ConnectX-5 and ConnectX-6) for VMware ESXi 6.5."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"676872","datemodified":"2022-01-28T05:09:36","file_list":["/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip","/cp050402.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/README.txt","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/release_note_nmlx5-rdma_4.16.71.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/doc/release_note_nmlx5-core_4.16.71.1-1OEM.650.0.0.4598673.pdf","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.16.71.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.16.71.1-1OEM.650.0.0.4598673.vib","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vendor-index.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vmware.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vibs/nmlx5-core--1864763229.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/vibs/nmlx5-rdma--1854117972.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_rdma-4.16.71.1.xml","/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-17702356.zip/MLNX-NATIVE-ESX-ConnectX-4-5_4.16.71.1-1OEM.650.0.0.4598673-offline_bundle-17702356.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-nmlx5_core-4.16.71.1.xml"],"md5sum":"04f9dac373849da4bc3d26d92f0502b0","name":"cp050402.zip","release":"2022-01-28T05:08:26","revision":"0","sha1sum":"476ecd21fe2ed82119a23fc5994c26e73f837196","size":"661KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48","20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821"],"type_of_change":"1","version":"2021.04.15","vib_list":[{"name":"nmlx5-rdma","version":"4.16.71.1-1OEM.650.0.0.4598673"},{"name":"nmlx5-core","version":"4.16.71.1-1OEM.650.0.0.4598673"}]}],"id":{"product":"b0057e5ba3444c3eb76eb15c0d0d8adc","version":"148704b1b89b40789905ee1e54ab01dd"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 \"nmlx5_en\" Driver Component for VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T12:59:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>An event will be sent to notify the administrator if the power required by the network adapter is higher than that available on the PCIe slot.</li>\n\t<li>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</li>\n\t<li>A&nbsp;new counter that enables the user to query per Virtual Function counters.</li>\n\t<li>RX out-of-buffer counter to indicate any lack of software receive buffers.</li>\n\t<li>Module parameter to enforce specific RoCE version.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command was not supported. When running this command on a vmknic, a failure message was displayed.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15(A):</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (Part Number: P42041-B21)</li>\n\t\t<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (Part Number: P42041-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>Added support for ConnectX-6 Lx devices.</li>\n\t<li>Scaled support for up to 10K connections over RDMA networks.</li>\n\t<li>Updated the module parameter &quot;supported_num_ports&quot; default value to 1 to lower memory constraints. Note: The user must set a value corresponding to the amount of ports installed in the system.</li>\n\t<li>Added &quot;sriov_mc_isolation&quot; module parameter to isolate multicast traffic to SR-IOV interfaces. Default value is OFF.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in driver version&nbsp;in 4.16.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>ConnectX-6 supported up to 100GbE speed link only.</p>\n\t</li>\n\t<li>\n\t<p>Live unload of the driver was&nbsp;not supported. Doing so may cause a PSOD if the max_vfs parameter was&nbsp;set.</p>\n\t</li>\n\t<li>\n\t<p>The maximum number of established active RDMA connections (QPs) was 5000.</p>\n\t</li>\n\t<li>\n\t<p>Setting ETS value to 0 caused WQE timeout.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx5-rdma:4.16.71.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-core:4.16.71.1-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"358890","datemodified":"2020-02-05T16:23:11","file_list":["/cp042919.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"073093bafe630e1dc71c1395a11fe424","name":"cp042919.zip","release":"2020-02-05T22:23:05","revision":"0","sha1sum":"9d045e2340350da0b9dd8e812c582e52a8c4108a","size":"350KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"4af400bbe27947109ef9222bacd0d2fd","version":"51edc3e8ce5e4b15a197316085ddafe6"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15792953","datemodified":"2021-08-30T07:35:06","file_list":["/CP048295_BUILD_2.data","/CP048295.vmexe","/CP048295.vmexe64","/CP048295.vmfile","/CP048295_VMw.zip","/CP048295.xml","/payload.json","/CP048295_VMw.zip/index.xml","/CP048295_VMw.zip/vendor-index.xml","/CP048295_VMw.zip/metadata.zip","/CP048295_VMw.zip/vib20/CP048295/HPE_bootbank_CP048295_HPG3.2-7.0.0.15843807.vib","/CP048295_VMw.zip/metadata.zip/vendor-index.xml","/CP048295_VMw.zip/metadata.zip/vmware.xml","/CP048295_VMw.zip/metadata.zip/vibs/CP048295-8081142903580322682.xml","/CP048295_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048295_HPG3.2-7.0.0.15843807.xml"],"md5sum":"658cc0993069335683739eba69f344fe","name":"CP048295.zip","release":"2021-08-30T07:29:43","revision":"0","sha1sum":"74059d8adb7877f07eadb34cf036d76874eaeb09","size":"15MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048295","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"31f6809eb59143388eb68360c8d0d7ac","version":"386d871897394fc28fa00e98012338fd"},"installation":{"command":"CP040680.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T09:09:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000GWXKK&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17574866","datemodified":"2021-08-27T18:37:33","file_list":["/CP049128_BUILD_1.data","/CP049128.vmexe","/CP049128.vmexe64","/CP049128.vmfile","/CP049128_VMw.zip","/CP049128.xml","/payload.json","/CP049128_VMw.zip/index.xml","/CP049128_VMw.zip/vendor-index.xml","/CP049128_VMw.zip/metadata.zip","/CP049128_VMw.zip/vib20/CP049128/HPE_bootbank_CP049128_HPG3.1-7.0.0.15843807.vib","/CP049128_VMw.zip/metadata.zip/vendor-index.xml","/CP049128_VMw.zip/metadata.zip/vmware.xml","/CP049128_VMw.zip/metadata.zip/vibs/CP049128-1230566697150109975.xml","/CP049128_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049128_HPG3.1-7.0.0.15843807.xml"],"md5sum":"9fa994f80ae0ffb0e59c5168f097b299","name":"CP049128.zip","release":"2021-08-27T18:32:14","revision":"0","sha1sum":"241b43d7b5a337e69d811e369fd45691e01594ec","size":"16MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP049128","version":"HPG3.1-7.0.0.15843807"}]}],"id":{"product":"660aa31b4e5e4c7fa47517faf21f93a1","version":"7cdfdd389d2c483db246d2f48a569e1d"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:18:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware&nbsp;revision corrects a rare situation where a Cryptographic Erase could result in random data instead of the expected deterministic zeros. This is judged as low severity because it does not compromise user data or security, but justifies the update to preclude potential security concerns. There are several items that reduce the probability of hangs and provide some minor performance improvements.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"962240","datemodified":"2021-11-02T15:39:54","file_list":["cp047084.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo5.dll","nicdrvr.dll","NicInVXS.dll","vxs65x64.cat","vxs65x64.din","vxs65x64.inf","vxs65x64.sys","vxsmsg.dll"],"md5sum":"a6b95884480d978e5f0437d11d58b681","name":"cp047084.exe","release":"2021-11-02T15:26:06","revision":"0","sha1sum":"ce9e2a5cc87261df14e78df6776abd1ad932527f","size":"939KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5c427f56"],"type_of_change":"0","version":"2.1.232.0"}],"id":{"product":"a786a49cd75640888a37e362b009fb3c","version":"3376370678a545a68dd8200d6d38d49a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel vxsドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInVXS.dll and vxsmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2310120","datemodified":"2021-08-26T09:26:23","file_list":["cp046790.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"3951a9d729444273ed172562d3fd2314","name":"cp046790.exe","release":"2021-08-26T09:24:04","revision":"0","sha1sum":"835ae643133cdd4b051d8938444e1f23e2573cff","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"1cf7a310ab4d4c49af4f9d9368690f44","version":"bcc352e0bc4b462eb737099e50691f7e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK003840GWHTE Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MK003840GWHTEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux&nbsp;(x64)&nbsp;-&nbsp;MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4969038","datemodified":"2021-07-23T07:44:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/CP048177.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/M51004G8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac20a1e1c6-HPG8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048177.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048177.scexe"],"md5sum":"527c4bd24316a558ffe687a0ab41648f","name":"firmware-hdd-ac20a1e1c6-HPG8-2.1.x86_64.rpm","release":"2021-07-23T07:30:17","revision":"0","sha1sum":"287e1eb6dcde198a218364919dd90efc1c4fb8f0","size":"4MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"e0a6e611d1444b4f8561da2a0566c408","version":"0d5d4f33e7dc4e21ad1a60e468344f16"},"installation":{"command":"CP041322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:16:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations. "},{"lang":"ja","x_late":"HPE MRSA Storage Administrator（HPE MRSA）ソフトウェアは、複数のユーザーがMegaRAID®製品のための監視、維持、トラブルシューティング、および構成機能を実行することを可能にするWebベースのアプリケーションです。MRSAグラフィカルユーザーインターフェイス（GUI）によって、既存のサーバーハードウェア構成を簡単に表示できます。また、これはストレージ構成の作成と管理にも役立ちます。このソフトウェアは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示します。このソフトウェアを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このソフトウェアを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"62472377","datemodified":"2021-09-14T14:13:03","file_list":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/3_04210_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_BGSanitize.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Change Drive Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure21-EnableTheUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Manage PCIe Storage Interface.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Mark Drive Offline.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Replace_Missing_Drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_background_operations.svg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_mail_server.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398236.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398345.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398429.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398469.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12698838.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13057592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13100187.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13111710.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13365465.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895285.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery-1.4.2.1-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery.flexslider-min.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/jquery_page_top_arrow.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/63C2E45CB45A465C8D53407524D7E5FF.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/948B09F082BDCBF81D5496A19E5890D4.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/EC76858D51A9C92959EC3735825CC13D.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/6AB35D2EB42441B41AAFB1934F9B98A3.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/8D40259B8CE49463AE3836D3BA7B9EBE.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/B5CD183A7E8F7863A4E5B17D5C17B05A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/47BB223EF06F049BC828364D0CC73B1E.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6227901A46DE11E7368CF1D7021032AA.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/795F47DD716BB083A21DD72E7DCDA43A.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/A33E682D8A44A8CC61711FE2D80B1DEC.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_horz.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/thumb_vertical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/css/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/0036BF84BBF761FA5A817B2AB5000709.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6EB4A93ACDD7659C40D6962BD4D66C32.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/89B92DC2898CEBCFD6E2C40ECDFD08FA.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/4826457BD7CBF50AFF02086731A9DED2.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/BFE9E66A49029BC46374B3D428E0831F.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/F90D9EFECF4C09C65F4037B0DDE10FD5.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"md5sum":"da5b3d0a9ef6910621cea8ae316510d6","name":"MRStorageAdministrator-007.016.016.000-00.x86_64.rpm","release":"2021-09-30T00:00:00","revision":"1","sha1sum":"a2fb6558e4ffcb0100b79ea21a25d86003eb7745","size":"59MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"type_of_change":"1","version":"7.016.16.0"}],"id":{"product":"c697574afe4243919c63d77cce675260","version":"50a834c83f304cb7a73ba4aaf0d16b66"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>HPEMRSA is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of HPEMRSA installed on the system, please use &quot;rpm -e &lt;rpm_name&gt;&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;rpm_name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in opt/HPEMRSA/LSIStorageAuthority.</li>\n</ul>\n"},{"lang":"ja","x_late":"<ul>\n\t<li>HPEMRSAはRed Hat Package Manager (RPM) パッケージを用いて配布されます。</li>\n\t<li>古いバージョンのHPEMRSAがシステムにインストールされている場合、\"rpm -e <rpm_name>\"を使用して最初にそれを削除してください。</li>\n\t<li>アプリケーションをインストールするためには、\"rpm -i <rpm_name>\"を使用します。</li>\n\t<li>RPMに関する詳細については \"man rpm\" と入力します。</li>\n\t<li>ソフトウェアはopt/HPEMRSA/LSIStorageAuthorityにあります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator (HPE MRSA) for Linux 64-bit"},{"lang":"ja","x_late":"Linux 64-bit用HPE MegaRAID Storage Administrator (HPE MRSA)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-04-13T10:12:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MRStorageAdministrator","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;&nbsp;VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2</p>\n\n<p><br />\n<strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20958308","datemodified":"2021-08-27T06:33:46","file_list":["/CP048469_BUILD_3.data","/CP048469.vmexe","/CP048469.vmexe64","/CP048469.vmfile","/CP048469_VMw.zip","/CP048469.xml","/payload.json","/CP048469_VMw.zip/index.xml","/CP048469_VMw.zip/vendor-index.xml","/CP048469_VMw.zip/metadata.zip","/CP048469_VMw.zip/vib20/CP048469/HPE_bootbank_CP048469_HPK3.3-7.0.0.15843807.vib","/CP048469_VMw.zip/metadata.zip/vendor-index.xml","/CP048469_VMw.zip/metadata.zip/vmware.xml","/CP048469_VMw.zip/metadata.zip/vibs/CP048469-9035756745624418070.xml","/CP048469_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048469_HPK3.3-7.0.0.15843807.xml"],"md5sum":"116b305af12f2159f32b665211ac1dea","name":"CP048469.zip","release":"2021-08-27T06:28:24","revision":"0","sha1sum":"a02dcdad6a4af73797c173ae9353323c5cf52a56","size":"19MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP048469","version":"HPK3.3-7.0.0.15843807"}]}],"id":{"product":"994a54e899fb4be5bf05bb0bf86539b6","version":"2162b782fbaf48fe97dc6857f785f7db"},"installation":{"command":"CP041138.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T14:01:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The HPE MRSA Storage Administrator (HPE MRSA) software is a web-based application that enables multiple users to perform monitoring, maintaining, troubleshooting, and configuration functions for the MegaRAID® products. The MRSA graphical user interface (GUI) makes it easy for you to view the existing server hardware configuration. It also helps you to create and manage storage configurations. The software displays the status of the controller cards, virtual drives, and drives on the controller. You can use the software to perform system maintenance tasks, such as updating the controller firmware. The software enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations.\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"49330928","datemodified":"2022-01-05T10:18:43","file_list":["cp050700.xml","cpqsetup.exe","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"md5sum":"0aeb6236e9229b8a13983ab8ec8a3d00","name":"cp050700.exe","release":"2022-01-05T10:16:30","revision":"0","sha1sum":"5d609f70190fd6c17a06170be1861671cec3b443","size":"47MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"type_of_change":"1","version":"7.16.16.0"}],"id":{"product":"d71ec216198e46cba0dfe25b58e109f0","version":"b69c4c1c1dcd4c048a4355fedc5cc2a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>If there is an older version of HPE MRSA installed on the system, please uninstall it by going to &quot;Control Panel -&gt; Uninstall a program&quot; and then uninstall &quot;LSA&quot;.</p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"},{"lang":"ja","x_late":"<p>HPE MRSAの古いバージョンがシステムにインストールされている場合、\"コントロールパネル ->プログラムのアンインストール\"からアンインストールを行った後に、\"LSA\"をアンインストールしてください。</p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator (HPE MRSA) for Windows 64-bit"},{"lang":"ja","x_late":"Windows 64-bit向けHPE MegaRAID Storage Administrator (HPE MRSA)"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-05T06:07:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Support Microsoft Windows Server 2022</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsa.exe","sw_key_expectedpath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under VMware vSphere 7.0"},{"lang":"ja","x_late":"このコンポーネントパッケージには、VMware vSphere 7.0で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.6.2.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.6.2.0が含まれています。</p>\n"}],"files":[{"bytes":"525057","datemodified":"2022-01-25T05:45:36","file_list":["/cp050788.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/index.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/vendor-index.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/metadata.zip","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/vib20/icen/INT_bootbank_icen_1.7.4.0-1OEM.700.1.0.15843807.vib","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/metadata.zip/vendor-index.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/metadata.zip/vmware.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/metadata.zip/vibs/icen--2570742064478961061.xml","/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807_19001931.zip/metadata.zip/bulletins/Intel-icen_1.7.4.0-1OEM.700.1.0.15843807.xml"],"md5sum":"18788e0a45d18515116525fe9d3badaf","name":"cp050788.zip","release":"2022-01-25T05:45:25","revision":"0","sha1sum":"d3f371b7d019ac5a453bec63d5845520479a632a","size":"512KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15","20a6e8e4-bf33-4c71-a6bf-d9ece43a8459"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"icen","version":"1.7.4.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"5f7ee6a6e6404443973d0cc0a41a28a3","version":"a559b60cdfde4a9fac5a8079cc3b7594"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for VMware vSphere 7.0"},{"lang":"ja","x_late":"Intel icea ドライバーfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-14T02:22:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with&nbsp;<em>Intel Firmware Package For E810 Ethernet Adapter</em>&nbsp;(PLDM)&nbsp;&nbsp;version 3.10</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icen:1.7.4.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-icen:1.7.4.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33603337","datemodified":"2022-03-08T12:59:47","file_list":["payload.json","U34_2.62_03_08_2022.signed.flash","U34_2.62_03_08_2022.xml"],"md5sum":"622fb2662493b734df0ce88c46cfb0bb","name":"U34_2.62_03_08_2022.fwpkg","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"5614f6a9bad010bd812cb252d66bcd5d05da9977","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"170e9646d84b43c984c43d017aedc665","version":"dd51c0efdba042288d848d0bd06aa7cb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:47","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>MPK75H5Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problem Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"9547371","datemodified":"2021-07-25T12:34:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/CP048227.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/MPK75H5Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK75H5Q-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048227.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048227.scexe"],"md5sum":"9019f67244fafea82b44d6304ab3e693","name":"firmware-hdd-e320db791d-MPK75H5Q-3.1.x86_64.rpm","release":"2021-07-25T12:21:04","revision":"0","sha1sum":"ad3cba47d3192a012d01bb1e0ce395382a811d47","size":"9MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"type_of_change":"2","version":"MPK75H5Q"}],"id":{"product":"5b139cd72d0b4c89818f276c3a1dce8c","version":"d6f696e709a84b54827dfa7a6c509c13"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:31:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Added support for VMD enabled Intel VROC platform</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"108000","datemodified":"2021-03-08T18:11:45","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"b3b57dda29e23e309de4df9c8806896a","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"8fb0af6de7ac770508fdb1950828ebb73bdc3848","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107845","datemodified":"2021-03-08T18:08:49","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"66ea757b46b623fa883d5d29e7effd81","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:02:04","revision":"0","sha1sum":"ff330ccbf17369a2d139194fe48965df3364558c","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"b25d6b61a6364a739b769a23e6051253","version":"60f89ebb45d044a299c4062fd1930599"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU&nbsp;and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4758666","datemodified":"2021-07-25T13:00:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/CP045365.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2a5b65f157-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045365.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045365.scexe"],"md5sum":"d7a272a1d68058b4d8a1557706056122","name":"firmware-hdd-2a5b65f157-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:34:04","revision":"0","sha1sum":"d90e42b8ed3b3261c604efe4d239b79dcaebd6b5","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"74b89b05406c4068843f3b27148a33d9","version":"65335ea2137647a1bb692bd75cc0b0bc"},"installation":{"command":"CP040087.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:13:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD1"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD1"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD1"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ</p>\n\n<p><strong>リリースバージョンおよび/または日付：</strong><br />\n     HPD1<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     なし<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n      なし<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n       なし</p>\n"}],"files":[{"bytes":"3850992","datemodified":"2021-12-13T08:36:22","file_list":["cp050457.xml","cpqsetup.exe","payload.json","setup.dll","TAPM6AFSHPD1.rel"],"md5sum":"54a0a012391aadebc262e97e8e0e2530","name":"cp050457.exe","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"d9cee9d041510839f8b740fedd529ab4a1437a22","size":"3MB","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"f1a885eabd844ec18e0dab540c21f1c8","version":"9746ed44c9474fccb67b9fbfb4269e8c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840XZCLT","target_guid":"562340a5-304f-3330-3834-30585a434c54","type":"sas"},{"id":"MO001600XZCLV","target_guid":"4d2340a5-304f-3130-3630-30585a434c56","type":"sas"},{"id":"MO000800XZCLQ","target_guid":"4d2340a5-304f-3030-3830-30585a434c51","type":"sas"},{"id":"VO007680XZCMB","target_guid":"562340a5-304f-3730-3638-30585a434d42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T10:45:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840XZCLT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600XZCLV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800XZCLQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680XZCMB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VO1920JEUQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO1920JEUQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16865614","datemodified":"2021-08-27T11:05:15","file_list":["/CP048419_BUILD_5.data","/CP048419.vmexe","/CP048419.vmexe64","/CP048419.vmfile","/CP048419_VMw.zip","/CP048419.xml","/payload.json","/CP048419_VMw.zip/index.xml","/CP048419_VMw.zip/vendor-index.xml","/CP048419_VMw.zip/metadata.zip","/CP048419_VMw.zip/vib20/CP048419/HPE_bootbank_CP048419_HPD3.5-7.0.0.15843807.vib","/CP048419_VMw.zip/metadata.zip/vendor-index.xml","/CP048419_VMw.zip/metadata.zip/vmware.xml","/CP048419_VMw.zip/metadata.zip/vibs/CP048419--811590486461629562.xml","/CP048419_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048419_HPD3.5-7.0.0.15843807.xml"],"md5sum":"777fbaeb32a5e8755303d932c4c0552f","name":"CP048419.zip","release":"2021-08-27T11:00:05","revision":"0","sha1sum":"3a091c58bbdecdf088b477f68eae9a900b3f7499","size":"16MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048419","version":"HPD3.5-7.0.0.15843807"}]}],"id":{"product":"9735a485aa1b43118b5c393eba2635c1","version":"4b5461abca2d4d16966ab31fcfb3c5e8"},"installation":{"command":"CP040555.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T15:52:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000480JWDAR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3438-304a57444152","Version":"HPD8"},{"DeviceName":"VO000960JWDAT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a57444154","Version":"HPD8"},{"DeviceName":"VO001920JWDAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a57444155","Version":"HPD8"},{"DeviceName":"VO003840JWDAV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633LD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a57444156","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000480JWDAR、VO000960JWDAT、VO001920JWDAUおよびVO003840JWDAV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3260520","datemodified":"2021-07-25T21:39:03","file_list":["cp044739.xml","cpqsetup.exe","G1633LD8.rel","payload.json","setup.dll"],"md5sum":"39b2925453f33a26001e630eae45cfe0","name":"cp044739.exe","release":"2021-07-25T21:32:13","revision":"0","sha1sum":"7c32d062c33bcb625dd745f75c3e20776cb17580","size":"3MB","target_guids":["562340a5-304f-3030-3438-304a57444152","562340a5-304f-3030-3936-304a57444154","562340a5-304f-3130-3932-304a57444155","562340a5-304f-3330-3834-304a57444156"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"38d33d1fd49e4ce68d34a95d7c8c3f1f","version":"f5419d7303514d568d381ec1624594b1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000480JWDAR, VO000960JWDAT, VO001920JWDAU and VO003840JWDAV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840JWDAV","target_guid":"562340a5-304f-3330-3834-304a57444156","type":"sas"},{"id":"VO001920JWDAU","target_guid":"562340a5-304f-3130-3932-304a57444155","type":"sas"},{"id":"VO000960JWDAT","target_guid":"562340a5-304f-3030-3936-304a57444154","type":"sas"},{"id":"VO000480JWDAR","target_guid":"562340a5-304f-3030-3438-304a57444152","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-08-01T12:36:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840JWDAV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWDAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000480JWDAR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWDAT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB, and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4772998","datemodified":"2021-07-23T08:29:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/CP048078.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/TA14SED8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7505dfb5ae-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048078.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048078.scexe"],"md5sum":"fa73ded3fd9c883ccbb649d435e1ab02","name":"firmware-hdd-7505dfb5ae-HPD8-2.1.x86_64.rpm","release":"2021-07-23T08:16:12","revision":"0","sha1sum":"ed0fd27686c36a261286e87053ea0bbe2d56cd77","size":"4MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"b24d5f9d7d1b43c1891a12ff33223756","version":"1b239b50a6a64407a2f1b1be78f8a58a"},"installation":{"command":"CP040286.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0600JETKA、EG0900JETKBおよびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:52:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Running SSADUCLI<br />\n------------------------------------------------------------------------<br />\nTo run the command-line application:&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp; Open a command prompt and change directory (cd) to the location<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; where SSADUCLI is installed.&nbsp; This is commonly<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; C:\\Program Files\\Smart Storage Administrator\\ssaducli\\bin.<br />\n&nbsp;&nbsp; To generate a diagnostic report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -f adu-report.zip</p>\n\n<p>&nbsp;&nbsp; To generate a SmartSSD Wear gauge report, enter the following command:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ssaducli -ssdrpt -f ssd-report.zip<br />\n&nbsp;&nbsp;<br />\n&nbsp;&nbsp; More options can be found by &quot;ssaducli -help&quot;.<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\nAdditional Notes<br />\n----------------<br />\nBoth the diagnostic and SmartSSD wear gauge reports are generated in compressed<br />\n&nbsp; (ZIP) format.</p>\n\n<p>The diagnostic report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * ADUReport.txt&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in text format<br />\n&nbsp;&nbsp; * ADUReport.xml&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; Diagnostic report in XML format<br />\n&nbsp;&nbsp; * ADUReport.htm&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; HTML viewer for diagnostic report<br />\n&nbsp;&nbsp; * report.checksum&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; =&gt; checksum file<br />\n&nbsp;&nbsp; * SlotX.txt (SlotX.old)&nbsp; =&gt; Controller serial output log</p>\n\n<p>&nbsp;&nbsp; Note: The serial output log file(s) are only available if the &quot;HPE Smart<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Array SAS/SATA Event Notification Service&quot; is installed and running.</p>\n\n<p>&nbsp;&nbsp; To view the diagnostic report in a browser, extract the ADUReport.htm. Open<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ADUReport.htm in the browser.</p>\n\n<p>The SmartSSD wear gauge report output archive contains the following files:</p>\n\n<p>&nbsp;&nbsp; * SmartSSDWearGaugeReport.txt&nbsp; =&gt; SmartSSD wear gauge report in text format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.json =&gt; SmartSSD wear gauge report in JSON format<br />\n&nbsp;&nbsp; * SmartSSDWearGaugeReport.htm&nbsp; =&gt; HTML viewer for the JSON wear gauge report</p>\n\n<p>&nbsp;&nbsp; To view the SmartSSD wear gauge report in a browser, extract the<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.json, SmartSSDWearGaugeReport.htm files to a<br />\n&nbsp;&nbsp; directory (both files must reside in the same directory).&nbsp; Open<br />\n&nbsp;&nbsp; SmartSSDWearGaugeReport.htm in the browser.</p>\n\n<p>Known Issues<br />\n------------<br />\n* When installing the 32-bit version of SSADUCLI on a system that has a<br />\n&nbsp; 64-bit (x64) version of SSADUCLI installed, please uninstall the 64-bit<br />\n&nbsp; version first. Failing to uninstall the 64-bit version will cause the 32-bit<br />\n&nbsp; installation to fail.</p>\n"}],"files":[{"bytes":"3400568","datemodified":"2022-01-24T07:30:16","file_list":["cp049696.xml","cpqsetup.exe","genericmsi.dll","SSADU53060_X64.msi"],"md5sum":"06f669cce7400ed3ad91d46a588dd213","name":"cp049696.exe","release":"2022-01-24T07:28:02","revision":"0","sha1sum":"41cbeaa7774cfd654b81350011bad237a06ee77b","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"3ac61ed209fd49fb908341fa7b77c3ea","version":"8078ffcb052f4325ab95f7b8258adebc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":90,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit"},{"lang":"ko","x_late":"Windows 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Windows版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:15:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022 for HPE ProLiant Gen10 and Gen10 Plus platforms only.</li>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli.exe","sw_key_expectedpath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55533","datemodified":"2021-07-21T17:54:23","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"14a9a554562a4d34270802b881e098d2","name":"kmod-hp-ixgbevf_bl-4.9.3-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:49:04","revision":"0","sha1sum":"e707ca288a43f5737b0ae4a9d7bd5f32900d7fdc","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"55676","datemodified":"2021-07-21T17:57:06","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/kmod-hp-ixgbevf_bl/component.xml"],"md5sum":"a968050da10613760865e9119a85faed","name":"kmod-hp-ixgbevf_bl-4.9.3-2.rhel8u3.x86_64.rpm","release":"2021-07-21T17:49:04","revision":"0","sha1sum":"a822a79a1ec3112dfc563f454f8f885e9f94992a","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec674b05ac"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"1645a3fa489f4a55a83d6b3479318292","version":"afe13ed3ddaf4aacbb7cb07f9cc31294"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1031728","datemodified":"2021-08-11T19:23:33","file_list":["cp047053.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt68x64.cat","ixt68x64.din","ixt68x64.inf","ixt68x64.sys","ixtmsg.dll","nicdrvr.dll"],"md5sum":"0d705743d9922bea2a618eae96202135","name":"cp047053.exe","release":"2021-08-11T19:09:05","revision":"0","sha1sum":"7b6160250673484851582dfe2c51f8224a7d1a2a","size":"0MB","target_guids":[],"type_of_change":"0","version":"4.1.228.0"}],"id":{"product":"47e104da8d1247009422e246e7ae204a","version":"1f009d9831be4a018d5e3f2d490f3f33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXT.dll and ixtmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020101","value":"HPE Superdome Flex Server"}],"sw_keys":[{"name":"ixt68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1345.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7590512","datemodified":"2021-09-15T04:40:50","file_list":["brcmflashStandalone-windows-12.0.1345.0-1/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/firmware/oc14-12.0.1345.0.ufi","brcmflashStandalone-windows-12.0.1345.0-1/win/","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/RM.INI","cp046757.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"b5840f0baff7183715559ec062449d4a","name":"cp046757.exe","release":"2021-09-15T04:22:59","revision":"0","sha1sum":"66daa0a46df6a78b4f249a1d9f580275b332d558","size":"7MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"2cfba0d873b646c19a7524c98b475007","version":"a4cb3f6e66c948249813ea6d1c90d419"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Microsoft Windows Server 2016/2019(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed a behavior with internal engineering data displays</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HPE 6Gb SAS BL Switch. After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HPE 6Gb SAS BLスイッチのファームウェアイメージが含まれています。コンポーネントをダウンロードしてディレクトリにファームウェアイメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Windows&nbsp;(x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.3.6.0 (B)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (C):</strong>&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>Improved integration with Smart Update Manager</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"34248016","datemodified":"2018-11-27T03:29:38","file_list":["cp038273.xml","cp_data.xml","Entry.bsh","vsm_release_4.3.6.0.img"],"md5sum":"dd34c209e5f44e8294c17058ac55a93a","name":"cp038273.exe","release":"2018-11-27T09:28:04","revision":"0","sha1sum":"a28dcfb93408d6ad568751c732f5dc51abb55f76","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"3ed50c140ece462d9878c300a512c4f5","version":"2b418b1cf2454e5d9af13cfa6c71ef45"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><strong>To update firmware from&nbsp;Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.&nbsp;</li>\n\t<li>Double-click on the Smart Component.&nbsp;</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the </strong><a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u>&nbsp;</a><strong>&nbsp;(SPP) and follow these steps:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the firmware to be updated in the directory, \\SPP20xxxxx\\packages on the USB key.</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。 </li>\n\t<li>Smartコンポーネントをダブルクリックします。 </li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\">HP Service Pack for ProLiant</a><u>（SPP）を入手して、以下の手順を実行することをおすすめします。</u></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの\\SPP20xxxxx\\packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HPE 6Gb SAS BL Switch Firmware Smart Component for Windows (x86/x64)"},{"lang":"ja","x_late":"オンラインHPE 6 Gb SAS BLスイッチファームウェアSmart Component for Windows (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"10"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-27T09:14:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>\n\t<p style=\"margin-left:0in; margin-right:0in\">Improved integration with Smart Update Manager</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20272275","datemodified":"2021-12-17T08:43:15","file_list":["/CP050549_BUILD_1.data","/CP050549.vmexe","/CP050549.vmexe64","/CP050549.vmfile","/CP050549_VMw.zip","/CP050549.xml","/payload.json","/CP050549_VMw.zip/index.xml","/CP050549_VMw.zip/vendor-index.xml","/CP050549_VMw.zip/metadata.zip","/CP050549_VMw.zip/vib20/CP050549/HPE_bootbank_CP050549_HPK1.1-7.0.0.15843807.vib","/CP050549_VMw.zip/metadata.zip/vendor-index.xml","/CP050549_VMw.zip/metadata.zip/vmware.xml","/CP050549_VMw.zip/metadata.zip/vibs/CP050549--9081991953768540040.xml","/CP050549_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050549_HPK1.1-7.0.0.15843807.xml"],"md5sum":"0f362a05a623feca20ce3bc3e5e93da5","name":"CP050549.zip","release":"2021-12-17T08:41:16","revision":"0","sha1sum":"3b953b334dfd2a475b13b00a8f05572f8a7a971b","size":"19MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"1","version":"HPK1","vib_list":[{"name":"CP050549","version":"HPK1.1-7.0.0.15843807"}]}],"id":{"product":"bc640709bf9a4728898e83ba80473c0a","version":"6bc1f5deafec4465806ba021e5896b55"},"installation":{"command":"CP040212.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-16T05:15:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p dir=\"rtl\">&nbsp;</p>\n"}],"files":[{"bytes":"7744760","datemodified":"2021-08-17T13:28:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/CP049304.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/KPE80X0AHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049304.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049304.scexe"],"md5sum":"ed1b7e1d865e6ede8ca523fcb687e70e","name":"firmware-hdd-035a863453-HPK3-2.1.x86_64.rpm","release":"2021-08-17T13:14:05","revision":"0","sha1sum":"bd0f130c4a0ca3e7bbc3fb54e3ff1bb832d1866c","size":"7MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"fdd1b58860474c42b7f3b1b7524af387","version":"1a3c729a891943d280530fccb58fd498"},"installation":{"command":"CP042953.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T13:09:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.55.27"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"ql_hp_ah_mbi_8.55.27_pldm.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.55.27"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、HPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v8.55.27.&nbsp;This combo image includes: Boot Code (MFW): 8.55.43.0, PXE:2.0.19, and UEFI: 4.1.13.0.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージには、コンボイメージv8.55.27が含まれています。 このコンボイメージには以下が含まれます。ブートコード（MFW）：8.55.43.0、PXE：2.0.19、UEFI：4.1.13.0</p>\n"}],"files":[{"bytes":"1827265","datemodified":"2022-01-27T04:37:03","file_list":["payload.json","ql_hp_ah_mbi_8.55.27_pldm.HPb","ql_hp_ah_mbi_8.55.27_pldm.xml"],"md5sum":"5a0b4706a86bd60fd35ad0b93786d417","name":"ql_hp_ah_mbi_8.55.27_pldm.fwpkg","release":"2022-01-27T04:31:42","revision":"0","sha1sum":"5834a866eaa6ea721a3f83e71a93b5bd7071c280","size":"1MB","target_guids":["a6b1a447-382a-5a4f-1077-80f0159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021d"],"type_of_change":"1","version":"8.55.27"}],"id":{"product":"066920f0b4684f1da260602d0174d2e0","version":"f8928eb97d30408682438e0ffc6f6eb7"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n\t<li>\n\t<p>Be noted that it needs the minimum version(combo image v8.55.12) for this firmware package, please refer to the following link to update firmware first.</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n\t<li>\n\t<p>このファームウェアパッケージには最小バージョン（コンボイメージv8.55.12）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c924ae49269f4d53b93dbb5ac5</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_829c3c2d15a641eeba5aebd3a2</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_117b0672d7ef4c5bb0eca02886</a></p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters"},{"lang":"ja","x_late":"Arrowheadアダプター用HPE QLogic FastLinQファームウェアパッケージ"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-03T07:37:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where the modification on string format of firmware update payload.</p>\n"},{"curr_enhancements_x_late":"<p>This product adjustment on platforms supported.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"NIC_FLQ_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3139704","datemodified":"2021-07-25T18:59:24","file_list":["cp048639.xml","cpqsetup.exe","M52004G3.rel","payload.json","setup.dll"],"md5sum":"cea207e496fe06b6f70c26486d3797a8","name":"cp048639.exe","release":"2021-07-25T18:52:06","revision":"0","sha1sum":"69ce051ddad4a48ca739e40b56aa64b4658afdde","size":"2MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"121ced484e6647bf98b3a4bca60530c2","version":"70781bbc0f16405ab48711473474efaa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK003840GWSXL ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:57:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11403104","datemodified":"2022-03-10T21:48:33","file_list":["cp051193.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_2.62_03_08_2022.signed.flash"],"md5sum":"dfe9c7ce2bd8011ae64c7daca668bd65","name":"cp051193.exe","release":"2022-03-10T21:46:48","revision":"0","sha1sum":"76f8e2c4c5464d61a71b53d88b911b13487e1cfa","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"2e589cc6a48f40eaa0870785c3351832","version":"9e2805030a134e80a7dde69e157d8040"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:0in; margin-right:0in\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p> </p>\n\n<p style=\"margin-left:0in; margin-right:0in\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant XL230k Gen10 (U37)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:01:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3035176","datemodified":"2021-07-23T19:08:47","file_list":["cp048560.xml","cpqsetup.exe","payload.json","setup.dll","TATCATRsnSD4.REL"],"md5sum":"7ef786214429f7cab7efbc8cc212bfd7","name":"cp048560.exe","release":"2021-07-23T19:01:05","revision":"0","sha1sum":"81e077fb3faa201fecd143c453ad57cc58658349","size":"2MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"2b0745f5d1b9423aa88e57ad4cdfbe00","version":"babc897cb01e43a2b63828a1da6dc53c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:16:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE 12Gb/s SAS Expander "},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE 12Gb/s SASエキスパンダーのファームウェアを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3614560","datemodified":"2021-08-17T13:55:19","file_list":["cp049280.xml","cpqsetup.exe","firmware-Signed-5.10-build-000.bin.fw","payload.json","setup.dll"],"md5sum":"81b0e0c6455e8061d01d923fb1a716be","name":"cp049280.exe","release":"2021-09-06T00:00:00","revision":"2","sha1sum":"e14ec2b47b95d6aa9991f68e99970ddead907aab","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10"}],"id":{"product":"b57ffa2f7fe942a89e589fe3043c5ffa","version":"efb80e12990e456a89930f3cbc38c24f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant&nbsp;</a>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには<a href=\"http://www.hpe.com/info/spp\" style=\"color:#0563c1; text-decoration:underline\">Service Pack for ProLiant</a></strong>から以下の手順に従ってください：</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"面向 Windows (x64) 的在线 ROM 刷新组件 – 适用于 HPE 智能阵列控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 扩展器固件"},{"lang":"tw","x_late":"適用於 Windows (x64) 的線上 ROM 更新元件 – HPE 12Gb/s SAS 擴充卡韌體，適用於 HPE Smart Array 控制器和 HPE HBA 控制器"},{"lang":"ko","x_late":"Windows(x64)용 온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS Expander 펌웨어"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE 12Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-11T08:49:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Add Windows 2022 support&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"9260797","datemodified":"2021-08-17T11:23:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/CP049301.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/K503HPG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049301.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049301.scexe"],"md5sum":"b9590fc65410041a95900f0e51eda985","name":"firmware-hdd-8e1e8083c5-HPG2-1.1.x86_64.rpm","release":"2021-08-17T11:10:04","revision":"0","sha1sum":"5d3a8db7b677fcddc1119b7642f856f6c8c51e55","size":"8MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"24bbe0adc4dc4c7385b6f5ad6aecf867","version":"2b767913d9d943e893ed3900eb2a17ae"},"installation":{"command":"CP043280.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T11:00:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller.  This driver is used by the Agentless Management Service, firmware flash components, and other utilities."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"570288","datemodified":"2021-09-03T15:41:57","file_list":["cp049467.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"md5sum":"c5418ae118ac3323e970d5eb62b05ace","name":"cp049467.exe","release":"2021-09-03T15:40:21","revision":"0","sha1sum":"aa211ccdd309e6e86bcfc81cf3036fe3a54d0730","size":"556KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"094c75ee866a4b1bb6f0e035ac316695","version":"e8d3de1047b34915a6a588c3533c7669"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-03T15:02:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixes driver destination folder</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"necheschif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM2_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM2_V1.20.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18de95518a","Version":"1.20"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM2 storage backplanes.\n\n"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM2ストレージバックプレーンをアップデートします。\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2224912","datemodified":"2022-02-23T05:54:22","file_list":["cp051208.xml","cpqsetup.exe","payload.json","setup.dll","UBM2_V1.20.hex.fw"],"md5sum":"64509f17c4fc3b2ecbf08130f3fbf283","name":"cp051208.exe","release":"2022-02-23T05:38:41","revision":"0","sha1sum":"c54c17b5f6f6605a97cef683c5e33c549067e358","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18de95518a"],"type_of_change":"1","version":"1.20"}],"id":{"product":"52d86414c1094be5a91709cfda5fa592","version":"b4faacbb470141709b280def1bbecea3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Firmware update takes effect immediately.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ファームウェアアップデートはすぐに有効になります。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10Plus UBM2 バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-22T13:58:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft&nbsp;Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEMDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5643407","datemodified":"2021-07-23T08:26:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/CP048081.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/STHBT2D5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a38b25661-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048081.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048081.scexe"],"md5sum":"e8cd24e3c3a0196be3974351463f2a53","name":"firmware-hdd-0a38b25661-HPD5-8.1.x86_64.rpm","release":"2021-07-23T08:14:05","revision":"0","sha1sum":"da4b7852be15615249b1cfa585c535304e22e386","size":"5MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"d2428e35050d42c7ba121ca5de5ea63c","version":"023db66966fd4b6e864b4f10965ad8a4"},"installation":{"command":"CP040287.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:01:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and&nbsp;MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15796724","datemodified":"2021-08-27T06:48:38","file_list":["/CP048390_BUILD_2.data","/CP048390.vmexe","/CP048390.vmexe64","/CP048390.vmfile","/CP048390_VMw.zip","/CP048390.xml","/payload.json","/CP048390_VMw.zip/index.xml","/CP048390_VMw.zip/vendor-index.xml","/CP048390_VMw.zip/metadata.zip","/CP048390_VMw.zip/vib20/CP048390/HPE_bootbank_CP048390_HPG3.2-7.0.0.15843807.vib","/CP048390_VMw.zip/metadata.zip/vendor-index.xml","/CP048390_VMw.zip/metadata.zip/vmware.xml","/CP048390_VMw.zip/metadata.zip/vibs/CP048390-6565617751817706618.xml","/CP048390_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048390_HPG3.2-7.0.0.15843807.xml"],"md5sum":"213175046eab0980f2d79169c642895c","name":"CP048390.zip","release":"2021-08-27T06:43:48","revision":"0","sha1sum":"93a7ad1407ad0c69518b2dfba6347ec463e069c5","size":"15MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048390","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"568141f535e3461e90494d5ac58c3991","version":"46833a0f1e6949838b4b3067ba4bd367"},"installation":{"command":"CP040679.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T11:06:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"DL20ML30Gen10SPS_05.01.04.400.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2002584","datemodified":"2022-01-26T03:26:23","file_list":["DL20ML30Gen10SPS_05.01.04.400.signed.bin","DL20ML30Gen10SPS_05.01.04.400.xml","payload.json"],"md5sum":"5fa62fa8c421b711171004905b3c5f13","name":"DL20ML30Gen10SPS_05.01.04.400.fwpkg","release":"2022-01-26T03:25:13","revision":"0","sha1sum":"96974b6464fa7140d0d01749d3c2b2ff8c73021a","size":"1MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"aacf76bfa7674de086e8a84063eadb98","version":"c2999a89f628449091885860be5f78a5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:01:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"596175","datemodified":"2022-02-10T08:06:37","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-348.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"7c5143cc633efeee2848e68529ac04ed","name":"kmod-elx-lpfc-12.8.528.24-1.rhel8u5.x86_64.rpm","release":"2022-02-10T07:59:11","revision":"0","sha1sum":"260323dcf95f02ae1ebccef60dde712ab081739c","size":"582KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.528.24"}],"id":{"product":"a1969a6dced74b848f7c8392464ddc8c","version":"7eeda3b366814c7a87ce8116ca50f870"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.528.22-1.rhel8u5.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 5 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-13T08:30:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.24</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VO1920JEUQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3336256","datemodified":"2021-07-25T19:46:37","file_list":["cp048645.xml","cpqsetup.exe","HSCPPCD3.rel","payload.json","setup.dll"],"md5sum":"c91883a7446e2d44a9f55f4d25e65719","name":"cp048645.exe","release":"2021-07-25T19:39:04","revision":"0","sha1sum":"3e3fb91e1bc58a4afce9a584946043f81a2085b0","size":"3MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"cbed2371ac3f4cd6a3df13f0ee8daa7b","version":"fe0102deebe242f8a8bf4886b7c775b8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:59:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.5"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.13.1.0.</p>\n"}],"files":[{"bytes":"218480","datemodified":"2021-11-03T07:42:48","file_list":["/cp049058.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/index.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/metadata.zip","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/vib20/i40en/INT_bootbank_i40en_1.14.3.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-i40en-1.14.3.0.xml","/VMW-ESX-6.5.0-i40en-1.14.3.0-offline_bundle-18666904.zip/metadata.zip/vibs/i40en--2875619686306351145.xml"],"md5sum":"576752bad604d4d04f571b9b84665405","name":"cp049058.zip","release":"2021-11-03T07:38:26","revision":"0","sha1sum":"a21ba350256d5b8fee028376f1f1a27bb81279b1","size":"213KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"i40en","version":"1.14.3.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"68498f6599c54afbbc323dc39761e931","version":"41dc2cf14a914f6ab0cc8946bd5c6de0"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel i40enドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-21T01:39:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports HPE ProLiant DL385 Gen10 Plus Server</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue where PSOD when drivers loading.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"i40en:1.14.3.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL&nbsp;and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4648223","datemodified":"2021-07-23T08:58:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/CP048192.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/GPM863G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a2d4b5c742-HPG1-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048192.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048192.scexe"],"md5sum":"3b807cc9d91c0711b7a2aa181b9a0cd3","name":"firmware-hdd-a2d4b5c742-HPG1-10.1.x86_64.rpm","release":"2021-07-23T08:45:10","revision":"0","sha1sum":"467f27b2ae18d07b42fad1e31797a4f8c0d7dcca","size":"4MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"149f4a8ca4634ca1990be51d125b79e4","version":"428d859915c14549ae54a46ac370155c"},"installation":{"command":"CP040295.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:30:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18712859","datemodified":"2021-08-30T19:42:01","file_list":["/CP048319_BUILD_2.data","/CP048319.vmexe","/CP048319.vmexe64","/CP048319.vmfile","/CP048319_VMw.zip","/CP048319.xml","/payload.json","/CP048319_VMw.zip/index.xml","/CP048319_VMw.zip/vendor-index.xml","/CP048319_VMw.zip/metadata.zip","/CP048319_VMw.zip/vib20/CP048319/HPE_bootbank_CP048319_HPG1.2-7.0.0.15843807.vib","/CP048319_VMw.zip/metadata.zip/vendor-index.xml","/CP048319_VMw.zip/metadata.zip/vmware.xml","/CP048319_VMw.zip/metadata.zip/vibs/CP048319-3624375847395312057.xml","/CP048319_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048319_HPG1.2-7.0.0.15843807.xml"],"md5sum":"df8b6b33039322522e7344a24bb5a7c3","name":"CP048319.zip","release":"2021-08-30T19:36:29","revision":"0","sha1sum":"a4103c3963fa64547b34aa055574707954ee3ff6","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048319","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"cc96bd351eff4426bf37f3da741a7623","version":"19ab963646bf4142be4e0aa9c6b2992c"},"installation":{"command":"CP041493.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000GWKGVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T11:12:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; GPK3</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18456984","datemodified":"2021-08-30T07:05:32","file_list":["/CP049284_BUILD_1.data","/CP049284.vmexe","/CP049284.vmexe64","/CP049284.vmfile","/CP049284_VMw.zip","/CP049284.xml","/payload.json","/CP049284_VMw.zip/index.xml","/CP049284_VMw.zip/vendor-index.xml","/CP049284_VMw.zip/metadata.zip","/CP049284_VMw.zip/vib20/CP049284/HPE_bootbank_CP049284_GPK3.1-7.0.0.15843807.vib","/CP049284_VMw.zip/metadata.zip/vendor-index.xml","/CP049284_VMw.zip/metadata.zip/vmware.xml","/CP049284_VMw.zip/metadata.zip/vibs/CP049284--4947017558253916959.xml","/CP049284_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049284_GPK3.1-7.0.0.15843807.xml"],"md5sum":"b4a4feb5632456de128b0cc504a64380","name":"CP049284.zip","release":"2021-08-30T07:00:42","revision":"0","sha1sum":"aaec92fcccd6fbc251ec065b3e3aa4e35d0b41af","size":"17MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3","vib_list":[{"name":"CP049284","version":"GPK3.1-7.0.0.15843807"}]}],"id":{"product":"c101b138be5d4ee79271a6725d6813d4","version":"fd57fa7c34fc4f748b36616a907458ee"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:11:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0480JFDGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3438-304a46444754","Version":"HPD9"},{"DeviceName":"VO0960JFDGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3936-304a46444755","Version":"HPD9"},{"DeviceName":"VO1920JFDGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a46444756","Version":"HPD9"},{"DeviceName":"VO3840JFDHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1633D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334f-3834-304a46444841","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO0480JFDGT, VO0960JFDGU, VO1920JFDGV, and VO3840JFDHA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： VO0480JFDGT、VO0960JFDGU、VO1920JFDGVおよびVO3840JFDHAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV&nbsp;and VO3840JFDHA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp;</strong> &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5060702","datemodified":"2021-07-23T09:34:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/CP048207.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/GP1633D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8ed8893abd-HPD9-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048207.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048207.scexe"],"md5sum":"b95ff5cd5171827f8d4a3531dce0cfeb","name":"firmware-hdd-8ed8893abd-HPD9-4.1.x86_64.rpm","release":"2021-07-23T09:19:09","revision":"0","sha1sum":"0dadfc437633b3b5a2151438a56fec66fd4bfa51","size":"4MB","target_guids":["002340a5-5600-304f-3438-304a46444754","002340a5-5600-304f-3936-304a46444755","002340a5-5600-314f-3932-304a46444756","002340a5-5600-334f-3834-304a46444841"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"13652737a6ea4ec4a4913fd807c0a85c","version":"bb7240a85785410f8b886ab52d751b4a"},"installation":{"command":"CP042220.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO0480JFDGT, VO0960JFDGU, VO1920JFDGV and VO3840JFDHA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO0480JFDGT、VO0960JFDGU、VO1920JFDGV、およびVO3840JFDHAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO3840JFDHA","target_guid":"002340a5-5600-334f-3834-304a46444841","type":"sas"},{"id":"VO1920JFDGV","target_guid":"002340a5-5600-314f-3932-304a46444756","type":"sas"},{"id":"VO0480JFDGT","target_guid":"002340a5-5600-304f-3438-304a46444754","type":"sas"},{"id":"VO0960JFDGU","target_guid":"002340a5-5600-304f-3936-304a46444755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:38:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0960JFDGU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO0480JFDGT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO3840JFDHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1920JFDGV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, and MB4000GDUPB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB1000GDUNU, MB2000GDUNV, MB3000GDUPA, およびMB4000GDUPBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"5246804","datemodified":"2021-07-23T06:09:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/CP048145.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/TAHARRG4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3ab4c70e64-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048145.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048145.scexe"],"md5sum":"63ea3f554703f861b12889e41bd31a80","name":"firmware-hdd-3ab4c70e64-HPG4-10.1.x86_64.rpm","release":"2021-07-23T05:54:06","revision":"0","sha1sum":"158e214d5fe182f118ad7e55309d1da2f2cdef1a","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"be75bc90ea544ceea229c5a0eeef825c","version":"3aa57d9599ac445ea7ec7ec936ad4508"},"installation":{"command":"CP040288.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、および MB4000GDUPB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:32:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3326207","datemodified":"2021-09-07T05:08:49","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1160.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"a29932afde378003bf885b6cdfd39a3c","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-09-07T05:02:43","revision":"0","sha1sum":"9d8ed96f0b3bffcd5110cf03fe820e8b7af7bd5c","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"676bdef4b7644815a191aa651f44dc5d","version":"146a5c5649f34507a2992cb9284ffdc0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.rhel7u9.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:12:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 7.9</li>\n</ul>\n\n<p>Updated to Driver version 12.0.1342.0</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where cluster nodes could be evicted during Fibre Channel over Ethernet (FCoE) multipath failover as described in <a href=\"https://access.redhat.com/solutions/3136041\">https://access.redhat.com/solutions/3136041</a></li>\n\t<li>Fixed a behavior where Ethernet connections may not recover after a Virtual Connect (VC) interconnect module reboot</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p><br />\n&nbsp; &nbsp; &nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"2902480","datemodified":"2021-07-24T07:03:24","file_list":["cp048481.xml","cpqsetup.exe","payload.json","setup.dll","TA13SED2.REL"],"md5sum":"843c798200406733b11d94e60e836c63","name":"cp048481.exe","release":"2021-07-24T06:55:11","revision":"0","sha1sum":"e343d0e3e5619d3cb1dd9f965e95467dba972e75","size":"2MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"e3b32b83ce544644bc4408de465e0c11","version":"a6d0f8a37cda4fe8b09f477d1568e8f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T03:45:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4385912","datemodified":"2021-07-23T10:13:56","file_list":["cp048545.xml","cpqsetup.exe","HLEBHasseFG2.rel","payload.json","setup.dll"],"md5sum":"4d6c032e129fd8a1420705d0deab8def","name":"cp048545.exe","release":"2021-07-23T10:06:11","revision":"0","sha1sum":"950c260d6604848e732b1e0d25e97d29db06c9b1","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"074cd65cf284444dbd64a63e5f809ff6","version":"eff018269bb044e38e8b4a37428b7135"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T12:27:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16015753","datemodified":"2021-08-27T10:47:39","file_list":["/CP048413_BUILD_4.data","/CP048413.vmexe","/CP048413.vmexe64","/CP048413.vmfile","/CP048413_VMw.zip","/CP048413.xml","/payload.json","/CP048413_VMw.zip/index.xml","/CP048413_VMw.zip/vendor-index.xml","/CP048413_VMw.zip/metadata.zip","/CP048413_VMw.zip/vib20/CP048413/HPE_bootbank_CP048413_HPG1.4-7.0.0.15843807.vib","/CP048413_VMw.zip/metadata.zip/vendor-index.xml","/CP048413_VMw.zip/metadata.zip/vmware.xml","/CP048413_VMw.zip/metadata.zip/vibs/CP048413-7453443161214509018.xml","/CP048413_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048413_HPG1.4-7.0.0.15843807.xml"],"md5sum":"5a0382d3550579c02ccc04ea6a0def3f","name":"CP048413.zip","release":"2021-08-27T10:42:03","revision":"0","sha1sum":"c92c7bcd41f51f1a9798f9835ee0d40eb01fcaa1","size":"15MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048413","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"c565c3f6bc0f4964b8b59efe8bfdfdea","version":"5aaa7432af0145b588834dd37133a1f6"},"installation":{"command":"CP040528.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T08:24:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEML and MB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17443341","datemodified":"2021-08-26T19:15:44","file_list":["/CP048361_BUILD_2.data","/CP048361.vmexe","/CP048361.vmexe64","/CP048361.vmfile","/CP048361_VMw.zip","/CP048361.xml","/payload.json","/CP048361_VMw.zip/index.xml","/CP048361_VMw.zip/vendor-index.xml","/CP048361_VMw.zip/metadata.zip","/CP048361_VMw.zip/vib20/CP048361/HPE_bootbank_CP048361_HPD6.2-7.0.0.15843807.vib","/CP048361_VMw.zip/metadata.zip/vendor-index.xml","/CP048361_VMw.zip/metadata.zip/vmware.xml","/CP048361_VMw.zip/metadata.zip/vibs/CP048361--6810381694176016378.xml","/CP048361_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048361_HPD6.2-7.0.0.15843807.xml"],"md5sum":"9217af76bb0c516c24eebea4d1603463","name":"CP048361.zip","release":"2021-08-26T19:10:28","revision":"0","sha1sum":"ec7aa8ed838288e80861670aaa8f5a356d0199cf","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6","vib_list":[{"name":"CP048361","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"193fefc836ff47bc98df145955f3145a","version":"7ba50602247a440da4bf7da81032d5b0"},"installation":{"command":"CP040640.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"},{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T11:54:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1291521","datemodified":"2021-11-09T06:23:57","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-ixgbevf","./lib/modules/5.3.18-57-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"2ff2bdfff5f095cf30e8432e98c983e3","name":"hp-ixgbevf-kmp-default-4.13.3_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-11-09T06:13:17","revision":"0","sha1sum":"764d6e01a4de238a5788dd3420d7553b401ea4ba","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.13.3-1"},{"bytes":"1255006","datemodified":"2021-11-09T06:25:22","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"md5sum":"fb0965f0f6b91faddf9022bba4be179e","name":"hp-ixgbevf-kmp-default-4.13.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-11-09T06:13:17","revision":"0","sha1sum":"7d1c2707c40ab1c45a44dcb4a5aab30f68231040","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"type_of_change":"0","version":"4.13.3-1"}],"id":{"product":"58259b45dec7469580dfbddb76171768","version":"ddaddb2a168542b88ecab9d1d776833b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where potential memory leak</li>\n\t<li>This product addresses an issue where eXpress Data Path(XDP) frame size calculations.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 7.0"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"820164","datemodified":"2021-08-27T04:12:40","file_list":["/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip","/cp046775.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/Readme-ESX70.qlnativefc","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/Release-ESX70-4.1.34.0.qlnativefc","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/doc/README.txt","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_4.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/vibs/qlnativefc-847282033782445070.xml","/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810-package.zip/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807_17541810.zip/metadata.zip/bulletins/MRVL-QLogic-FC_4.1.34.0-1OEM.700.1.0.15843807.xml"],"md5sum":"11e04db89b913b577b3d90ac2c20736a","name":"cp046775.zip","release":"2021-08-27T04:09:04","revision":"0","sha1sum":"c8a27a79b13e93df94e836e43beff6ee08350d94","size":"800KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"4.1.34.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"c1a4b1e8f3024c9bbd04b1730ba98308","version":"929b7bf7cc504440a49fd624bd5e7ccd"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Driver version 4.1.22.0</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where enabling VM-ID and SmartSAN on a boot from Storage Area Network (SAN) setup caused driver load incomplete</li>\n\t<li>Fixed a behavior where automatic attempts to recover from the behavior described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a> would result in a Purple Screen of Death (PSoD)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 4.1.34.0</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:4.1.34.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-QLogic-FC:4.1.34.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the Marvell FastLinQ 10/25/50 GbE Drivers for Microsoft Windows Server 2016, Microsoft Windows Server 2019 and Microsoft Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Marvell FastLinQ 10/25/50 GbEドライバーfor Microsoft Windows Server 2016、Microsoft Windows Server 2019、およびMicrosoft Windows Server 2022を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>Windows qevbd Driver is 8.58.16.0</li>\n\t<li>Windows qend Driver is 8.58.12.0</li>\n\t<li>Windows qefcoe Driver is 8.58.1.0</li>\n\t<li>Windows qxdiag Driver is 8.14.0.0</li>\n\t<li>Windows qeois Driver is 8.58.1.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>このコンポーネントは、以下のドライバーを含みます。</p>\n\n<ul>\n\t<li>Windows qevbdドライバー、8.58.16.0</li>\n\t<li>Windows qendドライバーは8.58.12.0</li>\n\t<li>Windows qefcoeドライバーは8.58.1.0です</li>\n\t<li>Windows qxdiagドライバーは8.14.0.0</li>\n\t<li>Windows qeoisドライバーは8.58.1.0です</li>\n</ul>\n"}],"files":[{"bytes":"6388976","datemodified":"2021-11-18T04:38:57","file_list":["cp049988.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"md5sum":"067e640a6910d01d2e94fb360e0a66bd","name":"cp049988.exe","release":"2021-11-18T04:25:22","revision":"0","sha1sum":"4cfc27f2daa8d3af50fd4e34ce5ca40fdf3f1ad7","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"type_of_change":"1","version":"8.58.20.0"}],"id":{"product":"8484f11834644aea8a2a14d1d0d58403","version":"18f60a6df978427eb8d217b959ad1b60"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"Marvell FastLinQ 10/25/50 GbEドライバー for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-17T08:10:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where RoCE+L2 traffic on MOS in NPAR mode</li>\n\t<li>This product correct an issue where transmitting under heavy PAUSE/Priority-based Flow Control (PFC)</li>\n\t<li>This product correct an issue where turning off VMs while VF RDMA traffic is running</li>\n\t<li>This product correct an issue where yellow bang while running VF RoCE traffic with overnight switch port.</li>\n\t<li>This product correct an issue where installing dirvers with iSCSI enumerated.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"qevbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"提供各種公用程式，以支援 HPE 支援的光纖通道主機匯流排配接卡驅動程式。"},{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."},{"lang":"ko","x_late":"HPE 지원 파이버 채널 호스트 버스 어댑터 드라이버의 다양한 유틸리티를 제공합니다."},{"lang":"cn","x_late":"提供支持 HPE 支持的光纤通道主机总线适配器驱动程序的其他实用程序。"},{"lang":"ja","x_late":"HPEのサポートされるファイバーチャネルホストバスアダプタードライバーのサポートに各種ユーティリティを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"26640","datemodified":"2022-02-10T07:31:22","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"4b302e17eeca5d9f550995f3ac3415f5","name":"fibreutils-4.2-1_rhel.x86_64.rpm","release":"2022-02-10T07:30:40","revision":"0","sha1sum":"97cc88d985e458ddf73fee970aeaed3a69a24837","size":"26KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.2-1"}],"id":{"product":"C8691","version":"4c2847597f04401db117050630e94d13"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"下載 fibreutil RPM。 <BR>使用 rpm -Uvh 命令來安裝/升級 RPM。"},{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."},{"lang":"ko","x_late":"fibreutils RPM을 다운로드합니다. <BR>rpm -Uvh 명령을 사용하여 RPM을 설치/업그레이드합니다."},{"lang":"cn","x_late":"下载 fibreutils RPM。 <BR>使用 rpm-Uvh 命令以安装/升级 RPM。"},{"lang":"ja","x_late":"fibreutils RPMをダウンロードします。 <BR>\nRPMをインストール/アップグレードするには、rpm -Uvhコマンドを使用してください"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -Red Hat Enterprise Linux (RHEL)"},{"lang":"ja","x_late":"Fibreutils for HPE Storageファイバーチャネルホストバスアダプター for Linux - Red Hat Enterprise Linux (RHEL)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This package supports only&nbsp;Red&nbsp;Hat Enterprise&nbsp;Linux&nbsp;(RHEL) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12535258","datemodified":"2021-08-24T15:26:14","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/ice","./lib/modules/5.3.18-57-default/updates/ice/ice.ko","./usr/share/smartupdate/ice-kmp-default/component.xml"],"md5sum":"76817f3dbf20bd8845a28f0990a83991","name":"ice-kmp-default-1.6.4_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-08-24T15:17:07","revision":"0","sha1sum":"bda79a5417f25aaac0423a91e210bae3d187c268","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"type_of_change":"1","version":"1.6.4-1"},{"bytes":"12393755","datemodified":"2021-08-24T15:29:40","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/ice","./lib/modules/5.3.18-22-default/updates/ice/ice.ko","./usr/share/smartupdate/ice-kmp-default/component.xml"],"md5sum":"88885c51960f59ca24e57d9feb2534ff","name":"ice-kmp-default-1.6.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-24T15:17:07","revision":"0","sha1sum":"f34502534094a944d7e94f5dd4e597be638148de","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"type_of_change":"1","version":"1.6.4-1"}],"id":{"product":"29a000381a7c4ec8a72063a155821a0a","version":"5798c4f77f0746ba9921a879933103e4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel ice Drivers for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"ice-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"ice-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"ice-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"ice-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1666714","datemodified":"2021-08-27T06:03:22","file_list":["./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles12sp5/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles12sp5/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"c4c391421bff8ffd52ff448a51ba1087","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles12sp5.x86_64.rpm","release":"2021-08-27T05:56:33","revision":"0","sha1sum":"d1d6791bc58d5cee7f39d3f68c7d01e6eb0d232a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"a3459c07ef5f45fe84a4a598d99e1833","version":"5b2aaba9800f4a67b20e140afa5ee52e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22433","datemodified":"2021-12-14T15:19:33","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/kernel-mft-mlnx","./lib/modules/4.18.0-348.el8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/4.18.0-348.el8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"c65ab494bf379c8d4740a79648e6493c","name":"kmod-kernel-mft-mlnx-4.18.0-1.rhel8u5.x86_64.rpm","release":"2021-12-14T15:09:04","revision":"0","sha1sum":"23ae5a6166ae37101c4675349594dae7f8906bc9","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"},{"bytes":"7972361","datemodified":"2021-12-14T15:22:20","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/lib/.build-id","./usr/lib/.build-id/23","./usr/lib/.build-id/23/8e04ea9d1cf5e4d0bffa2a9ffa905215b11233","./usr/lib/.build-id/25","./usr/lib/.build-id/25/272a22133bc8f2bc269bd589dffd7cfe97b019","./usr/lib/.build-id/45","./usr/lib/.build-id/45/04084bdf52792335f6c316b8406200d7c3d2a5","./usr/lib/.build-id/77","./usr/lib/.build-id/77/f42cbb45647acdb6c1fbd09aa3dc4aae607096","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/d9336da78216d68defc4981c0181f49cc2ac1c","./usr/lib/.build-id/da","./usr/lib/.build-id/da/df0749c5859fdf544ff22ccaa1eb7b692eb3a6","./usr/lib/.build-id/df","./usr/lib/.build-id/df/da077576e46c79bb580489bd0bd52ff689cf44","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"77e78b84e60497ec16273a4ba9eef5cf","name":"mft-4.18.0-106.rhel8u5.x86_64.rpm","release":"2021-12-14T15:09:04","revision":"0","sha1sum":"dd7921e1a5ee90e5a3e2e26626a90d9033558c22","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"}],"id":{"product":"36be4b500e2d45ccb5e9acc5b5158451","version":"2352bdae5bc24d09832baaa950f1086b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using kernel version 4.18.0-305.el8.x86_64&nbsp;or any future errata:<br />\n<strong># rpm -Uvh&nbsp;kmod-kernel-mft-mlnx-4.18.0-1.rhel8u4.x86_64.rpm&nbsp;&nbsp;mft-4.18.0-78.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 8 Update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:49:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWJNP and EG001200JWJNQ&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4086144","datemodified":"2021-07-24T07:49:40","file_list":["cp048457.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ND4.rel"],"md5sum":"bb2b8af1b17a99808857c8141f8cc6bb","name":"cp048457.exe","release":"2021-07-24T07:43:07","revision":"0","sha1sum":"b47c648826302764583c7e1f112e4a7ea228adb5","size":"3MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"5ac3ee90b2184fa9828f960cd9d17840","version":"c4457210fdee4ade8edacc5c02939430"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T09:30:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"nmlx5_en Ethernet driver (ConnectX-4, ConnectX-5 and ConnectX-6) for VMware ESXi 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"704226","datemodified":"2022-01-28T05:10:58","file_list":["/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip","/cp050401.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/README.txt","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/release_note_nmlx5-core_4.17.71.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/doc/release_note_nmlx5-rdma_4.17.71.1-1OEM.670.0.0.8169922.pdf","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vib20/nmlx5-core/MEL_bootbank_nmlx5-core_4.17.71.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/vib20/nmlx5-rdma/MEL_bootbank_nmlx5-rdma_4.17.71.1-1OEM.670.0.0.8169922.vib","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vendor-index.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vmware.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vibs/nmlx5-core--2359207540222518703.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/vibs/nmlx5-rdma--5396774233207068486.xml","/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-17650904.zip/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922-offline_bundle-17650904.zip/metadata.zip/bulletins/Mellanox-nmlx5_4.17.71.1-1OEM.670.0.0.8169922.xml"],"md5sum":"fcfd35ebfd4936e3f27ed28de644fe73","name":"cp050401.zip","release":"2022-01-28T05:09:24","revision":"0","sha1sum":"dc23815ff7d5c1ce07b2a21f3e5e6efe56d9451c","size":"687KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41bd2821","20a6e8e4-bf33-4c71-a6bf-d9ecdebb2a48"],"type_of_change":"1","version":"2021.04.15","vib_list":[{"name":"nmlx5-core","version":"4.17.71.1-1OEM.670.0.0.8169922"},{"name":"nmlx5-rdma","version":"4.17.71.1-1OEM.670.0.0.8169922"}]}],"id":{"product":"8e7aaa71b17c4086a95b8b9f64ce4863","version":"5ad1023485c14570b0b624fd809a68b9"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx/ and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 \"nmlx5_en\" Driver Component for VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T12:55:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15:</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>HPE Ethernet 200Gb 1-Port QSFP56 MCX623105AS-VDAT Adapter (HPE Part Number: P10180-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in version 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Disabled the option of shutting down the link due to power limitation.</p>\n\t</li>\n\t<li>\n\t<p>Support for trusting Differentiated Services Code Point (DSCP) and setting default value for RoCE traffic.</p>\n\t</li>\n\t<li>\n\t<p>New counter that enables the user to query per Virtual Function counters.</p>\n\t</li>\n\t<li>\n\t<p>RX out-of-buffer counter to indicate any lack of software receive buffers.</p>\n\t</li>\n\t<li>\n\t<p>Module parameter to enforce specific RoCE version.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version&nbsp;in 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The &quot;esxcli network sriovnic vf stats&quot; command&nbsp;was not supported.When running this command on a &quot;vmknic&quot;, a failure message&nbsp;was displayed.</p>\n\t</li>\n\t<li>\n\t<p>IPv6 as inner packet was not supported.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Changes and New Features in smart component version 2021.04.15(A):</strong></p>\n\n<ul>\n\t<li>Added support for the following adapters:\n\t<ul>\n\t\t<li>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (Part Number: P42041-B21)</li>\n\t\t<li>Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (Part Number: P42041-B21)</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p><strong>New features and changes in driver version 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for ConnectX-6 Lx devices.</p>\n\t</li>\n\t<li>\n\t<p>Scaled support for up to 10K connections over RDMA networks.</p>\n\t</li>\n\t<li>\n\t<p>Updated the module parameter &quot;supported_num_ports&quot; default value to 1 to lower memory constraints. Note: The user must set a value corresponding to the amount of ports installed in the system.</p>\n\t</li>\n\t<li>\n\t<p>Added &quot;sriov_mc_isolation&quot; module parameter to isolate multicast traffic to SR-IOV interfaces. Default value is OFF.</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in driver version&nbsp;in 4.17.71.1:</strong></p>\n\n<ul>\n\t<li>\n\t<p>SRI-OV was not supported while ENS was enabled.</p>\n\t</li>\n\t<li>\n\t<p>Live unload of the driver was not supported. Doing so aused&nbsp;a PSOD if the max_vfs parameter was set.</p>\n\t</li>\n\t<li>\n\t<p>The maximum number of established active RDMA connections (QPs) was 5000.</p>\n\t</li>\n\t<li>\n\t<p>ENS was not supported in ConnectX-6 Dx adapter cards.</p>\n\t</li>\n\t<li>\n\t<p>Setting ETS value to 0 caused WQE timeout.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmlx5-core:4.17.71.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"nmlx5-rdma:4.17.71.1-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18503306","datemodified":"2021-08-30T20:24:52","file_list":["/CP048331_BUILD_2.data","/CP048331.vmexe","/CP048331.vmexe64","/CP048331.vmfile","/CP048331_VMw.zip","/CP048331.xml","/payload.json","/CP048331_VMw.zip/index.xml","/CP048331_VMw.zip/vendor-index.xml","/CP048331_VMw.zip/metadata.zip","/CP048331_VMw.zip/vib20/CP048331/HPE_bootbank_CP048331_HPG1.2-7.0.0.15843807.vib","/CP048331_VMw.zip/metadata.zip/vendor-index.xml","/CP048331_VMw.zip/metadata.zip/vmware.xml","/CP048331_VMw.zip/metadata.zip/vibs/CP048331--6204746841176718845.xml","/CP048331_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048331_HPG1.2-7.0.0.15843807.xml"],"md5sum":"a7d4b1ab85581b70f26814672d6c45dd","name":"CP048331.zip","release":"2021-08-30T20:20:08","revision":"0","sha1sum":"8e9fce27ccee73be883bf105977af66e12250ab2","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048331","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"a6447acbde7f4368991a3df1503f91e8","version":"ca282a25bee64bf087ea6774b2bdb640"},"installation":{"command":"CP041481.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000GWRTCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:50:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-30475746574b","Version":"HPG6"},{"DeviceName":"MB002000GWFWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRH620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-30475746574c","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWFWK and MB002000GWFWL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB001000GWFWK and MB002000GWFWL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4004968","datemodified":"2021-07-23T19:35:21","file_list":["cp048557.xml","cpqsetup.exe","payload.json","setup.dll","WRH620G6.rel"],"md5sum":"2f4ac3306a8e8df6f6f6ac810db0055f","name":"cp048557.exe","release":"2021-07-23T19:28:07","revision":"0","sha1sum":"ab221e04a4aed0a50de546a8036ee3ca8eb2a35b","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-30475746574b","4d2340a5-3042-3230-3030-30475746574c"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"57a91e286d3e413c8468376551e64001","version":"34c053d109ae450f8d8adc1896d5bfff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWFWK and MB002000GWFWL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB001000GWFWKおよびMB002000GWFWLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFWK","target_guid":"4d2340a5-3042-3130-3030-30475746574b","type":"sata"},{"id":"MB002000GWFWL","target_guid":"4d2340a5-3042-3230-3030-30475746574c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:42:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000GWFWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWFWK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MM1000GFJTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します： MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5423037","datemodified":"2021-07-23T07:50:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/CP046354.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/SAVGNTG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95af9a555e-HPG5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046354.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046354.scexe"],"md5sum":"ab69c699f5cb3ff045930fe82a842b80","name":"firmware-hdd-95af9a555e-HPG5-6.1.x86_64.rpm","release":"2021-07-23T07:36:06","revision":"0","sha1sum":"06b139ec7ff900359136b2b5e72a8ab06e2d0469","size":"5MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"e8a7c3696813408f916249b859b6b722","version":"1a18f589c1164370908a926a777e95a4"},"installation":{"command":"CP040344.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000GFJTE Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-25T07:08:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"605488","datemodified":"2021-12-21T04:33:07","file_list":["cp050589.xml","cpqsetup.exe","installer.dll","pnp/","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"md5sum":"0a01d2b3af2122bfe3ef7002a6e63aae","name":"cp050589.exe","release":"2021-12-21T04:30:56","revision":"0","sha1sum":"2b53da46634ef001cacd04f0eea35764b1663fc4","size":"591KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"id":{"product":"21c71338fdf2430b8b41f3737620822c","version":"ba73b01ba2374ceba6a886aeb5018a74"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":3600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows"},{"lang":"ja","x_late":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第1および第2世代）識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-21T04:25:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Modified install time</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed version control issues</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong><strong>Enhancements/New Features</strong>:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2731608","datemodified":"2021-07-25T16:29:03","file_list":["cp048621.xml","cpqsetup.exe","GSV843G3.rel","payload.json","setup.dll"],"md5sum":"7ccdaa92e112660621c354fae951f888","name":"cp048621.exe","release":"2021-07-25T16:22:07","revision":"0","sha1sum":"d43e4392be5f35348f14421c50bb4d06157c8281","size":"2MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"d3eb22b830d045a89e85774c90558992","version":"7863a89aa5284ec39e86949796165b8e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:48:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000JXLBA and MB018000JXLAU Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6930734","datemodified":"2021-08-11T18:37:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/CP049255.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/WpariscASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049255.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049255.scexe"],"md5sum":"6f1056cbdba6ba36246e778468fb065b","name":"firmware-hdd-d550523365-HPD2-1.1.x86_64.rpm","release":"2021-08-11T18:24:06","revision":"0","sha1sum":"d34d0787587f53761d1c93599793df54da008d43","size":"6MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"d287970503c042a480f1860ec2c054c7","version":"eeffc0a67db34a318cb6db36f76f16da"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T18:15:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"6397387","datemodified":"2021-08-16T16:57:29","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnx2.ko","./lib/modules/4.12.14-120-default/updates/bnx2fc.ko","./lib/modules/4.12.14-120-default/updates/bnx2i.ko","./lib/modules/4.12.14-120-default/updates/bnx2x.ko","./lib/modules/4.12.14-120-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"507b5beb5af982bec3350b1fe0a273dd","name":"netxtreme2_bl-kmp-default-7.14.80_k4.12.14_120-5.sles12sp5.x86_64.rpm","release":"2021-08-16T16:40:04","revision":"0","sha1sum":"ab972c9f35dc2c6d6fa9a6af76caf5df07ca0e85","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"6f63395ea958425f83bb31303381afd1","version":"d687baf1f76b4e73b726b31a7cdde904"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with firmware version 1.5.x.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"95181","datemodified":"2021-08-24T16:51:29","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/ec","./usr/lib/.build-id/ec/395064640281498bce40c7c8067c43efcd6123","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"c07778b5c6c8c4cdb9cd0a25953419cd","name":"kmod-hp-iavf-4.2.7-1.rhel8u3.x86_64.rpm","release":"2021-08-24T16:35:05","revision":"0","sha1sum":"a6a4ff63aa102daabbabb04406fdcf7db7d1fa69","size":"92KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"},{"bytes":"95310","datemodified":"2021-08-24T16:45:44","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-iavf","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/82","./usr/lib/.build-id/82/56fef0f45c9581aa85257f22034eda8a842a0e","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"md5sum":"f3260a4c5ef383271f2c20adbc51422e","name":"kmod-hp-iavf-4.2.7-1.rhel8u4.x86_64.rpm","release":"2021-08-24T16:35:05","revision":"0","sha1sum":"276dd88a8780eefb3243fb6d86b576fe82f077d2","size":"93KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"26d6bb7ca1354a5998790d5fa42f5aa8","version":"37907d27ee8e41a9ae26eb5f564dcf81"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel iavf ドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>&nbsp;</p>\n\n<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-iavf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"StorCLI は複数のユーザーが MegaRAID® 製品の維持、トラブルシューティング、および構成の機能の実行を可能にするコマンド ライン インターフェイスです。 ストレージ構成の作成と管理をすることもできます。 StorCLI はコント ローラー上のコント ローラー カード、仮想ドライブ、そしてドライブのステータスを表示することができます。 CLI を使用してコント ローラーのファームウェアのアップデートなどのシステム メンテナンス タスクを実行することができます。 このツールはコント ローラーの監視とコント ローラーの仮想ドライブおよびドライブを構成することを可能にします。 簡単に新しいストレージ構成を作成したり構成を変更することができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2720776","datemodified":"2018-12-13T08:53:58","file_list":["cp036918.xml","cpqsetup.exe","install.xml","multisetup.dll","StorCLI.msi"],"md5sum":"daa7af959475b91876166f241663c9cc","name":"cp036918.exe","release":"2018-12-13T14:52:03","revision":"0","sha1sum":"2a697a4105185dd1a119701b42c3b8130989b75e","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"type_of_change":"0","version":"1.25.12.0"}],"id":{"product":"42eb0b14ee764418a766256ac492f5b9","version":"16db44a089104cfb9cf6570d36545834"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n\n<p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p>\n\n<p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバーのWindowsオペレーティングシステムからStorcliユーティリティを実行するには：</strong></p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>\n\n<p>インストールが完了したら、コマンドプロンプト環境を実行し、%programfiles%\\MR Storage Administrator\\StorCLI\\binフォルダーに移動し、Storcli64.exeユーティリティを実行します</p>\n\n<p>例：<strong>Storcli64.exe /c0 show </strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit"},{"lang":"ja","x_late":"Windows 64-bit用HPE MegaRAID Storage Administrator StorCLI"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-08-05T15:31:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Improved integration with Smart Update Manager.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Release For Snap4</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server (private)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"storcli64.exe","sw_key_expectedpath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>EPK75H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"7568064","datemodified":"2021-07-24T08:40:42","file_list":["cp048301.xml","cpqsetup.exe","EPK75H3Q.rel","payload.json","setup.dll"],"md5sum":"10e1262bc2f7aa07518cc5361320528a","name":"cp048301.exe","release":"2021-07-24T08:33:14","revision":"0","sha1sum":"ab70f50275318527a79a657c6467622bdb09cc0f","size":"7MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q"}],"id":{"product":"99c23ff7c8d6427fabec401028b615d8","version":"cae6f90f03de48aa8b92195060b0d66b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor Windows (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T11:11:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6148374","datemodified":"2021-07-23T08:14:10","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/CP048132.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/HVLAeAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048132.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048132.scexe"],"md5sum":"388a6c1c1559ca6d9b690e42c757695a","name":"firmware-hdd-a886842a99-HPD2-2.1.x86_64.rpm","release":"2021-07-23T08:01:13","revision":"0","sha1sum":"a067c36af3386ff6f1fba7859d3fe9bf92663469","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"9ea83d5d4cdf449690664479d7c8538a","version":"1ac367c3c29041abb54079d02fb76138"},"installation":{"command":"CP041488.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB006000JWKGN ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:20:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO1920JEUQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSCPPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3932-304a45555151","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:VO1920JEUQQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：VO1920JEUQQのファームウェアを提供します"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5210912","datemodified":"2021-07-23T09:05:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/CP048196.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/HSCPPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5d9e841607-HPD3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048196.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048196.scexe"],"md5sum":"5ffe61f150e24c778e8d470d6b9f135a","name":"firmware-hdd-5d9e841607-HPD3-8.1.x86_64.rpm","release":"2021-07-23T08:52:12","revision":"0","sha1sum":"1f3fd43d03e9f54f95394591cf7967c05a9ee693","size":"4MB","target_guids":["002340a5-5600-314f-3932-304a45555151"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5c979876c84d42aba65fe31d9aa00e1f","version":"e795c5cb9ce040dd85e3022caa264bb0"},"installation":{"command":"CP040312.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO1920JEUQQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO1920JEUQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO1920JEUQQ","target_guid":"002340a5-5600-314f-3932-304a45555151","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:44:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO1920JEUQQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for ESXi&nbsp;(x64) -&nbsp;HPE&nbsp;Smart Array P824i-p MR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0043(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</li>\n</ul>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4951562","datemodified":"2020-07-17T09:10:26","file_list":["/CP044920.vmexe","/CP044920.vmfile","/CP044920.xml","/payload.json","/README.txt"],"md5sum":"bf7db14bd598932eedb0886e08c8611a","name":"CP044920.zip","release":"2020-07-17T09:08:05","revision":"0","sha1sum":"8af86c31265f6dac89dde3112cef74e58f5ccb23","size":"4MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"0","version":"24.23.0-0043","vib_list":[]}],"id":{"product":"b9e7f18a1693495cbaf0b6cf2ac1c5fb","version":"38e72a5698934d138dfdc5794b157441"},"installation":{"command":"CP044920.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, extract the Smart Component tp temporary folder. For example: ./CPXXXXXX.vmexe --unpack=tmp</li>\n\t<li>Change directory to&nbsp;tmp folder&nbsp;location</li>\n\t<li>Execute ./flash_ctrl_1.04.sh</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントtmp一時フォルダーを解凍します。例：./CPXXXXXX.vmexe --unpack=tmp</li>\n\t<li>ディレクトリをtmpフォルダーの場所に変更します</li>\n\t<li>./flash_ctrl_1.04.shを実行します</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for ESXi (x86) - HPE Smart Array P824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-16T14:12:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>\n\t<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n\t<p>Please reference Customer Advisory&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00101958en_us\">a00101958en_us</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6563224","datemodified":"2021-08-13T14:20:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/CP049273.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/M5210AG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4b4177239b-HPG2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049273.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049273.scexe"],"md5sum":"4ae3542a63e89af8af2bf78d6e632b37","name":"firmware-hdd-4b4177239b-HPG2-2.1.x86_64.rpm","release":"2021-08-13T14:08:04","revision":"0","sha1sum":"e3aaadc5fa3c15510be0fa03f9685b20802e7aae","size":"6MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"920be7efa67449a4b47e25f2db58a48e","version":"3c9b40b2406949feb955cb54b133bafa"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:01:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers. "},{"lang":"ja","x_late":"Smart Storage Administrator CLIは、SmartアレイコントローラーおよびSmartRAIDコントローラー用のコマンドラインベースのディスク構成プログラムです。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"7631655","datemodified":"2022-02-02T17:39:25","file_list":["/cp050291.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/index.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/vendor-index.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/metadata.zip","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/vib20/hpessacli/MIS_bootbank_hpessacli_5.30.6.0-7.0.0.15525992.oem.vib","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/metadata.zip/vendor-index.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/metadata.zip/vmware.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/metadata.zip/vibs/hpessacli-6859894788269631305.xml","/hpessacli-component_5.30.6.0-7.0.0_19303168.zip/metadata.zip/bulletins/hpessacli-component_5.30.6.0-7.0.0.xml"],"md5sum":"1e0123c1c449a2a0f562984e61860d26","name":"cp050291.zip","release":"2022-02-02T17:39:09","revision":"0","sha1sum":"2736c22ac5a4b8d2a7a2afb0abed258c840779b0","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc5c305d1","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"hpessacli","version":"5.30.6.0-7.0.0.15525992.oem"}]}],"id":{"product":"91a15c09dbd5425fbdb19fbefcf76977","version":"d47cde91f14c4f30bbffa99205c1b9c2"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 7.0 "},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) CLI Smartコンポーネントfor ESXi 7.0 "}],"prerequisites":{"required_diskspace":{"size_kb":"7100"},"supported_devices":[{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"},{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21cc","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cc","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21CD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cd","type":"pci","ven":"103c"},{"dev":"A106","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a106159000c0","type":"pci","ven":"8086"},{"dev":"A107","subdev":"00C0","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a107159000c0","type":"pci","ven":"8086"},{"dev":"3239","subdev":"21ce","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ce","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21cb","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21cb","type":"pci","ven":"103c"},{"dev":"8D66","subdev":"009D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d661590009d","type":"pci","ven":"8086"},{"dev":"8D06","subdev":"009C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-8d061590009c","type":"pci","ven":"8086"},{"dev":"193F","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-193f103c3381","type":"pci","ven":"103C"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21be","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21be","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c0","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c0","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21ca","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21ca","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21BD","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bd","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c4","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c4","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c9","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c9","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21bf","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21bf","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c7","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c7","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c6","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c6","type":"pci","ven":"103c"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-23T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"hpessacli-component:5.30.6.0-7.0.0","sw_key_expectedpath":"software.component:vmware:zip"},{"name":"hpessacli:5.30.6.0-7.0.0.15525992.oem","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GEBTP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16643795","datemodified":"2021-08-26T20:22:37","file_list":["/CP048370_BUILD_2.data","/CP048370.vmexe","/CP048370.vmexe64","/CP048370.vmfile","/CP048370_VMw.zip","/CP048370.xml","/payload.json","/CP048370_VMw.zip/index.xml","/CP048370_VMw.zip/vendor-index.xml","/CP048370_VMw.zip/metadata.zip","/CP048370_VMw.zip/vib20/CP048370/HPE_bootbank_CP048370_HPG4.2-7.0.0.15843807.vib","/CP048370_VMw.zip/metadata.zip/vendor-index.xml","/CP048370_VMw.zip/metadata.zip/vmware.xml","/CP048370_VMw.zip/metadata.zip/vibs/CP048370--1305886891935817215.xml","/CP048370_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048370_HPG4.2-7.0.0.15843807.xml"],"md5sum":"df108452e6266d553ccb0c2f4787007d","name":"CP048370.zip","release":"2021-08-26T20:17:33","revision":"0","sha1sum":"e97740543ac05e855c7f64bf8b22a9b9fdd35903","size":"15MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048370","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"f08c2998f0194b1483b2e21050a3b5a3","version":"303a095dffab410caaf6224b981c4413"},"installation":{"command":"CP040543.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T20:39:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1188.0が含まれています。</p>\n"}],"files":[{"bytes":"3566056","datemodified":"2020-06-11T04:19:57","file_list":["/cp044544.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"8072d670a52c8573702fa8b2af21fc31","name":"cp044544.zip","release":"2020-06-11T04:19:05","revision":"0","sha1sum":"c6a321999115f6ff6f29b278cac6601a7ec4f199","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7fae0e3a1408427d859a7147aca14a11","version":"d6ee5259298e469584ecb1092196dca4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.7.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含的套件 QLogic 光纖通道主機匯流排配接卡的 Linux 作業系統上提供對 Smart SAN 的支援。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Linux operating systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 QLogic 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"ja","x_late":"このパッケージは、LinuxオペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"18511","datemodified":"2021-08-27T04:07:38","file_list":["./opt/hpe/ql_smartsan/ql_ss_enablement","./opt/hpe/ql_smartsan/qlssen.sh","./opt/hpe/ql_smartsan/qlssen.txt","./usr/share/smartupdate/hpe-qlogic-smartsan-enablement-kit/component.xml"],"md5sum":"0dbed7f094006e3f797affd24855289b","name":"hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm","release":"2021-08-27T04:00:24","revision":"0","sha1sum":"de6d625514e53f13751bb7abc083f0c6a1a75b5f","size":"18KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd61cbbea"],"type_of_change":"0","version":"3.3-3"}],"id":{"product":"8be880867f274999951d42eb0e3b0aa8","version":"6b0f1985a662486da4078f979c5b8777"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p>\n\n<p style=\"margin-left:40px\">To uninstall the QLogic Smart SAN enablement RPM use the following command:</p>\n\n<p style=\"margin-left:40px\"># rpm -e hpe-qlogic-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p>\n\n<p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-qlogic-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-qlogic-smartsan-enablement-kit-3.3-3.x86_64.rpm</p>\n\n<p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 QLogic SmartSAN 啟用套件"},{"lang":"en","x_late":"HPE QLogic Smart SAN enablement kit for Linux"},{"lang":"ko","x_late":"Linux용 QLogic SmartSAN 인에이블먼트 키트"},{"lang":"ja","x_late":"HPE QLogic Smart SAN イネーブルメントキット（Linux）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-19T10:36:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added Support to RHEL8 and SLES15SP1</p>\n\n<p>Updated to version 3.3-3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 3.3-3</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"hpe-qlogic-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"58edf963-9038-4e01-80c5-59b770e09e25","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"UBM3_V1.24.signed.hex.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"V1.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10Plus UBM3 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、ProLiant Gen10Plus UBM3ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"62632","datemodified":"2022-02-25T06:21:52","file_list":["payload.json","UBM3_V1.24.signed.hex.ilo","UBM3_V1.24.xml"],"md5sum":"9d2feb1287b07835ca78913e70c38c90","name":"UBM3_V1.24.fwpkg","release":"2022-02-25T06:18:37","revision":"0","sha1sum":"166143a5cfebe072a67c2169ce095cd8ffc26131","size":"61KB","target_guids":["9675b54e-1c96-44c3-a7a1-901503000000"],"type_of_change":"1","version":"1.24"}],"id":{"product":"3dc958db65ab4d0f834facaa57c7058d","version":"a52fed0685a049b995cd082b616ef377"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10Plus UBM3 Backplane PIC Firmware"},{"lang":"ja","x_late":"ファームウェアパッケージ - Gen10Plus UBM3 Backplane PICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-07T10:25:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3PIC","sw_key_expectedpath":"firmware:ubmbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.19.31"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading  Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, NCSI, and CCM code running under vSphere 7.0."},{"lang":"ja","x_late":"このパッケージには、vSphere 7.0で動作するBroadcom NX1 Gigabit Ethernet NICブートコード、PXE、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3697327","datemodified":"2021-09-05T17:10:03","file_list":["/CP048908_BUILD_25.data","/CP048908.vmexe","/CP048908.vmexe64","/CP048908.vmfile","/CP048908_VMw.zip","/CP048908.xml","/payload.json","/CP048908_VMw.zip/index.xml","/CP048908_VMw.zip/vendor-index.xml","/CP048908_VMw.zip/metadata.zip","/CP048908_VMw.zip/vib20/CP048908/HPE_bootbank_CP048908_1.29.3.25-7.0.0.15843807.vib","/CP048908_VMw.zip/metadata.zip/vendor-index.xml","/CP048908_VMw.zip/metadata.zip/vmware.xml","/CP048908_VMw.zip/metadata.zip/vibs/CP048908--3065564454171005772.xml","/CP048908_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048908_1.29.3.25-7.0.0.15843807.xml"],"md5sum":"7edb9cca833105fe4b854e9d81df03f3","name":"CP048908.zip","release":"2021-09-17T00:00:00","revision":"1","sha1sum":"16c553666295b2ed06c3e651acc4b5f1b31d9e98","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"1.29.3","vib_list":[{"name":"CP048908","version":"1.29.3.25-7.0.0.15843807"}]}],"id":{"product":"83f19a40734047f1a91d25f9cd465999","version":"b9a8a22b77134f84a9ce20cad51c49a0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<li>VMwareコンポーネントをインストールします。\n\t<ul>\n\t\t<li>a. ESXi 7.0ターゲットの場合：esxcli software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<li>b. ESXi 6.xターゲットの場合：esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ul>\n\t</li>\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ul>\n\t\t<li>a. /opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<li>b. Smartコンポーネントをクリーンアップするには：\n\t\t<ul>\n\t\t\t<li>i. ESXi 7.0ターゲットの場合：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii. ESXi 6.xターゲットの場合：esxcli software vib remove –n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c. CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"Broadcom NX1オンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-23T02:06:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"BCM_OPEN","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33601066","datemodified":"2022-03-10T21:51:06","file_list":["payload.json","U37_2.62_03_08_2022.signed.flash","U37_2.62_03_08_2022.xml"],"md5sum":"801de8b2e8d412597ee50b0410b2263a","name":"U37_2.62_03_08_2022.fwpkg","release":"2022-03-10T21:47:16","revision":"0","sha1sum":"18f708d9320baa3fb44264888375069df300ca2f","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"644b370c36714c6490fce699ffce22e9","version":"e24a717aabea4b2a888c294d90fb40b7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:02:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB VR001920GWFMC ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5036658","datemodified":"2021-07-23T08:44:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/CP048184.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/M5100MGG.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9196d4f720-HPGG-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048184.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048184.scexe"],"md5sum":"e838eefbcb0ac0ac8cb8a7a370fd0c3f","name":"firmware-hdd-9196d4f720-HPGG-2.1.x86_64.rpm","release":"2021-07-23T08:32:08","revision":"0","sha1sum":"cde1b8ed507d325aa568a88f2cff7f95b22f6d13","size":"4MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"a6840b5d0ec24ee78bf7a78ec26db476","version":"231cd2df5396414980da86fafb6370b9"},"installation":{"command":"CP041316.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMB、およびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:50:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5550738","datemodified":"2021-07-23T06:14:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/CP048149.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/HAKPNFG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-70e3962f98-HPG6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048149.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048149.scexe"],"md5sum":"fbf17f8ee78bf0b29b6746f488623cb1","name":"firmware-hdd-70e3962f98-HPG6-9.1.x86_64.rpm","release":"2021-07-23T06:02:08","revision":"0","sha1sum":"7960b01f46abab8269f3760cc117c96df1561940","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"1195ecfa03744617a13d6f9abdc72e2b","version":"65118f0cbb71454f9b48bf4991440400"},"installation":{"command":"CP040331.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:49:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2022 for the HPE Smart Array S100i SR Gen10 SW RAID"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1691616","datemodified":"2021-09-07T04:08:08","file_list":["cp049244.xml","cpqsetup.exe","generic.dll","install.xml","smartdq-win.sarif","smartdq.cat","SmartDQ.inf","SmartDQa.sys","SmartDQco002.dll","SmartDQp.sys","SmartDQr.sys"],"md5sum":"47fda2ae5267d1a1fa61d7e4a34f19c1","name":"cp049244.exe","release":"2021-09-07T04:02:38","revision":"0","sha1sum":"c92b375e9fc99f2d9fc7b55e27244c9d8e40ee71","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59"],"type_of_change":"1","version":"1010.14.0.0"}],"id":{"product":"09fdb681b4924b8992d4cc199252815c","version":"4307382e470743d08456c40b490704a1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T03:39:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE Apollo k6000 Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"SmartDQa.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MM1000JFJTH and MM002000JWCNF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5424949","datemodified":"2021-07-23T07:58:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/CP048181.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/SAVGNSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-fa46c607d6-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048181.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048181.scexe"],"md5sum":"de642dd2c520c434af7f85ed1983ef8d","name":"firmware-hdd-fa46c607d6-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:46:05","revision":"0","sha1sum":"eedb7c7d2a6a71049720e228aafe97d4d039e415","size":"5MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"aedaa041caed4345872545de3f1efa40","version":"a01a176831b54244a95df145f1f7ce84"},"installation":{"command":"CP040294.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:41:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050852.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2167909","datemodified":"2022-01-26T03:32:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/CP050855.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/cp050852.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/cp050852.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.04.400-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050855.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050855.scexe"],"md5sum":"e17e28d9422b1dbeafad3bf0b5212548","name":"firmware-dl20ml30gen10sps-05.01.04.400-1.1.x86_64.rpm","release":"2022-01-26T03:26:49","revision":"0","sha1sum":"281bf29107584654b8b6b18ef99592cb353f50cc","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"e9b531c475a54ce6b287402b5c425933","version":"3f722273f44b4259b5b4b3412eb4f1a6"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>Verify the RPM signature using the following steps:</strong></p>\n\n<p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p>\n\n<p>Import the public key while logged in as root by running the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>Verify the RPM:</strong></p>\n\n<p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p>\n\n<p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p>\n\n<p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p>\n\n<p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p>\n\n<p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p><strong>次の手順を使用してRPM署名を確認します:</strong></p>\n\n<p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：https://downloads.linux.hpe.com/keys.html</p>\n\n<p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします:</p>\n\n<p>   # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>RPMを検証します：</strong></p>\n\n<p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p>\n\n<p>   # rpm --checksig filename_of_the_rpm</p>\n\n<p>   example result #  rpm --checksig <filename>.rpm</p>\n\n<p>  <filename>.rpm: digests signatures OK</p>\n\n<p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p>\n\n<p>   # rpm --checksig sample_file.rpm</p>\n\n<p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20/ML30 Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:00:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-004080897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-524580897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-a74a80897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-fc4f80897b09","Version":"2.2.0.1553"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Linux Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"483251","datemodified":"2021-06-21T07:45:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/CP047913.xml","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/cp048252.compsig","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/cp048252.zip","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dcpmm-2.2.0.1553-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047913.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047913.scexe"],"md5sum":"a56e0590dc3c83a050157a94f758983c","name":"firmware-dcpmm-2.2.0.1553-2.1.x86_64.rpm","release":"2021-06-21T07:37:18","revision":"0","sha1sum":"8acb2098616b54accbcdedf6452c79baab62d48b","size":"471KB","target_guids":["805dd01c-eb5a-1e76-8089-004080897b09","805dd01c-eb5a-1e76-8089-524580897b09","805dd01c-eb5a-1e76-8089-a74a80897b09","805dd01c-eb5a-1e76-8089-fc4f80897b09"],"type_of_change":"1","version":"2.2.0.1553"}],"id":{"product":"4345a02bdd6249338219baeef555995e","version":"2a0e572e4c0e46e28e022f937335f446"},"installation":{"command":"CP043329.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ol>\n\t<li>Install the firmware rpm using the command: rpm -ivh &lt;rpm_filename&gt;.&nbsp;</li>\n\t<li>This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location. After installation, navigate into this folder.</li>\n\t<li>The CPxxxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:<br />\n\t<br />\n\t# <em>./CPxxxxxx.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)<br />\n\t<br />\n\t# <em>./hpsetup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location<br />\n\t&nbsp;</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ol>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ol>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-dcpmem-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;firmware-dcpmem-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ol>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use&nbsp;Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ol>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory,&nbsp;/SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow HPE Smart Update Manager steps to complete firmware update.</li>\n</ol>\n\n<p><strong>Online:</strong></p>\n\n<ol>\n\t<li>Login as root. (You must be root in order to apply the&nbsp;update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></p>\n\n<ol>\n\t<li>コマンド rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </li>\n\t<li>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。インストール後、このフォルダーに移動します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'hp-scexe-compat'フォルダーにあります。'firmware-dcpmem-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：<br />\n\t<br />\n\t# <em>./CPxxxxxx.scexe</em>（'/usr/lib/x86_64-linux-gnu/hp-scexe-compat'で実行）（または）<br />\n\t<br />\n\t# <em>./hpsetup</em>（'/usr/lib/x86_64-linux-gnu/firmware-dcpmem-*'で実行）<br />\n\t </li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ol>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ol>\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id.  これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-dcpmem-*'ロケーションに移動し、./hpsetupを実行してファームウェアをアップデートします。'firmware-dcpmem-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ol>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ol>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HPE Smart Update Managerの手順に従って、ファームウェアのアップデートを完了します。</li>\n</ol>\n\n<p><strong>オンライン：</strong></p>\n\n<ol>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Plus Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue that three different capacities of Intel Optane DC Persistent Memory are identifiable&nbsp;with three individual device GUID.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000JVYYV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp; MB6000JVYYV Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17578189","datemodified":"2021-08-27T04:27:40","file_list":["/CP048379_BUILD_2.data","/CP048379.vmexe","/CP048379.vmexe64","/CP048379.vmfile","/CP048379_VMw.zip","/CP048379.xml","/payload.json","/CP048379_VMw.zip/index.xml","/CP048379_VMw.zip/vendor-index.xml","/CP048379_VMw.zip/metadata.zip","/CP048379_VMw.zip/vib20/CP048379/HPE_bootbank_CP048379_HPD2.2-7.0.0.15843807.vib","/CP048379_VMw.zip/metadata.zip/vendor-index.xml","/CP048379_VMw.zip/metadata.zip/vmware.xml","/CP048379_VMw.zip/metadata.zip/vibs/CP048379-5268119834730916793.xml","/CP048379_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048379_HPD2.2-7.0.0.15843807.xml"],"md5sum":"056ae73cbb235fcf1cc63293d242ea8e","name":"CP048379.zip","release":"2021-08-27T04:23:03","revision":"0","sha1sum":"72a43ff52949fea860d4ef9679d05ddecce6f271","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048379","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"ecd26cd8b6e9412ba22bff66e6f6bbbe","version":"1f173493e5ad4232bf84b2dac8b9f444"},"installation":{"command":"CP040534.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:49:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサー内のデバイスを識別するためのドライブなしのINFを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"663576","datemodified":"2021-12-21T03:33:41","file_list":["cp050588.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/amddrtm.cat","pnp/amddrtm.dll","pnp/amddrtm.inf","pnp/AmdIOV.cat","pnp/AmdIOV.inf","pnp/amdpcidev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"md5sum":"fe988172e09e6d92fe61e3d2244fc21c","name":"cp050588.exe","release":"2021-12-21T03:31:50","revision":"0","sha1sum":"deaa54f95cffcf64e06431c87a4dcb9a726e56c1","size":"648KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"1","version":"4.2.0.0"}],"id":{"product":"500c2e8334cb4bd793078241d6489395","version":"184964d1400c457d9e60d571ffaf7add"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for AMD EPYC Processors for Microsoft Windows"},{"lang":"ja","x_late":"Microsoft Windows用AMD EPYCプロセッサーの識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-21T03:26:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added PSHED Plug-in driver</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed version control issues</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK007680GWSXNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK007680GWSXN&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5007880","datemodified":"2021-07-23T08:56:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/CP048191.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/M52008G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048191.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048191.scexe"],"md5sum":"9eab53f756bc4ab4edc0798ad0c0ed27","name":"firmware-hdd-b460823f70-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:43:19","revision":"0","sha1sum":"292d9ae86684c04e0980665ad4842015ea782071","size":"4MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"0c319cd0bae843d891d1e9696a4b873b","version":"2545ec4bb8694330bcd38b4a2eca9b76"},"installation":{"command":"CP040780.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:17:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4769108","datemodified":"2021-07-23T08:17:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/CP048087.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/TA13SXD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1cbab97ff0-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048087.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048087.scexe"],"md5sum":"0170a560cd27136476dffe51cad77bab","name":"firmware-hdd-1cbab97ff0-HPD5-8.1.x86_64.rpm","release":"2021-07-23T08:05:10","revision":"0","sha1sum":"e6a6fb91e7a2d5659c457a9e4a085e537177b705","size":"4MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8c2e806c31134d5f896832d57e01f96c","version":"f5443d165b6c4c5592a820a5765040fc"},"installation":{"command":"CP040282.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JDXBA、EH0450JDXBBおよびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:26:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes.\n\n"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM3ストレージバックプレーンをアップデートします。\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3951203","datemodified":"2022-01-17T14:19:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/CP050752.xml","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/UBM3_V1.24.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-1.24-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050752.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050752.scexe"],"md5sum":"997b5297229a9cb1865dd133a99c9bff","name":"firmware-ff3fa73ca1-1.24-1.1.x86_64.rpm","release":"2022-01-17T14:02:46","revision":"0","sha1sum":"125e74aa3d8a94d143bee2b4c43cba809584914b","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.24"}],"id":{"product":"52abbcdaa353433f863db3360468056d","version":"3390ca1a75d94b2091405354883e7463"},"installation":{"command":"CP050752.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP049064.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-ff3fa73ca1-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP049064.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p style=\"margin-left:40px\">&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-ff3fa73ca1-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><em><strong>rpmインストールによるファームウェアのアップデート：</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/x86_64-linux-gnu'の場所へrpmの内容を解凍します。</li>\n\t<li>CP049064.scexeスクリプトは'hp-scexe-compat'フォルダーにあります。'firmware-ff3fa73ca1-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：</li>\n</ul>\n\n<p>               # ./ CP049064.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</p>\n\n<p style=\"margin-left:40px\">     # ./setup（'/usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-*'で実行）</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは'.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><em><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します：rpm2cpio <rpm_filename>.rpm | cpio -id  これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-ff3fa73ca1-*'に移動し、./setupを実行してファームウェアをアップデートします。'firmware-ff3fa73ca1-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><em><strong>追加情報：</strong></em></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記に概説した手順に従う必要があります。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM3 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Linux - Gen10Plus UBM3バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:32:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3082.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7 and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するIntel Gigabit Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12675858","datemodified":"2021-11-01T13:54:46","file_list":["/CP049898_BUILD_3.data","/CP049898.vmexe","/CP049898.vmexe64","/CP049898.vmfile","/CP049898_VMw.zip","/CP049898.xml","/payload.json","/CP049898_VMw.zip/index.xml","/CP049898_VMw.zip/vendor-index.xml","/CP049898_VMw.zip/metadata.zip","/CP049898_VMw.zip/vib20/CP049898/HPE_bootbank_CP049898_3.16.50.3-7.0.0.15843807.vib","/CP049898_VMw.zip/metadata.zip/vendor-index.xml","/CP049898_VMw.zip/metadata.zip/vmware.xml","/CP049898_VMw.zip/metadata.zip/vibs/CP049898--7396647421518330955.xml","/CP049898_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049898_3.16.50.3-7.0.0.15843807.xml"],"md5sum":"129b7cef8a26893a715e11e92c863a31","name":"CP049898.zip","release":"2021-11-01T13:49:44","revision":"0","sha1sum":"8b413d8873274a21e6ac420a247c86c5c89d4c02","size":"12MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"3.16.50","vib_list":[{"name":"CP049898","version":"3.16.50.3-7.0.0.15843807"}]}],"id":{"product":"a08198f75ae64d5f81f313aee3e10a81","version":"599862da3128480d82c987feb9727859"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Installation instructions are available in CP047006.txt, which is included in CP047006.zip.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>インストール手順は、CP047006.zipに含まれているCP047006.txtでご利用いただけます。</p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"Intelオンラインファームウェアアップグレードユーティリティfor VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-01T07:02:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 u3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1027328","datemodified":"2021-08-18T16:11:33","file_list":["cp049075.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"6eb15db30e000b484554e14c812feea7","name":"cp049075.exe","release":"2021-08-18T15:57:19","revision":"0","sha1sum":"e2b6193d7f7a84cb0e0a734549f1689817243460","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.197.0"}],"id":{"product":"cad34a66b4fc4a06bf8a262ac99afab3","version":"295af7fd26214475a9270cb0398fd66f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library ixtmsg.dll.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.11.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E8","Version":"1.11.000"},{"DeviceName":"HPE 100Gb 1p OPA 860z FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.11.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F01590021C","Version":"1.11.000"},{"DeviceName":"HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.11.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0159000E7","Version":"1.11.000"},{"DeviceName":"Intel Corporation Omni-Path HFI Silicon 100 Series [discrete]","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HfiPcieGen3Loader_1.11.0.0.0.rom","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-24F0808624F0","Version":"1.11.000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE OPA firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE OPAファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>OPA HFI Adapter Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>SSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 100Gb 1-Port OP101 QSFP28 x8 OPA Adapter</td>\n\t\t\t<td>1.11.0.0.0</td>\n\t\t\t<td>E7</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 100Gb 1-Port OP101 QSFP28 x16 OPA Adapter&nbsp;</td>\n\t\t\t<td>1.11.0.0.0</td>\n\t\t\t<td>E8</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo 100Gb 1-port Intel Omni-Path Architecture 860z Mezzanine FIO Adapter</td>\n\t\t\t<td>1.11.0.0.0</td>\n\t\t\t<td>21C</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"269606","datemodified":"2021-09-20T10:01:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/CP049225.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/CP049225.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/HfiPcieGen3Loader_1.11.0.0.0.rom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/HfiPcieGen3_1.11.0.0.0.efi","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/hfi1_eprom","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/nic_fw/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-opa-hfi-1.11.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049225.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049225.scexe"],"md5sum":"af76727abceb587dcef3b51cbabd7e9d","name":"firmware-nic-intel-opa-hfi-1.11.0-1.1.x86_64.rpm","release":"2021-10-18T00:00:00","revision":"1","sha1sum":"a14bdaf04ff43dea3e597b3975036ffa11fae286","size":"263KB","target_guids":["a6b1a447-382a-5a4f-8086-24F0159000E8","a6b1a447-382a-5a4f-8086-24F01590021C","a6b1a447-382a-5a4f-8086-24F0159000E7","a6b1a447-382a-5a4f-8086-24F0808624F0"],"type_of_change":"1","version":"1.11.0"}],"id":{"product":"7943f29050984f1f850b2530e1fd78f4","version":"7e7a5dfca56c4c879457c5697675886f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE OPA adapters"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64)for HPE OPAアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"24F0","subdev":"00E8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e8","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"021C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f01590021c","type":"pci","ven":"8086"},{"dev":"24F0","subdev":"00E7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-24f0159000e7","type":"pci","ven":"8086"},{"dev":"24f0","subdev":"24f0","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-24f0808624f0","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T13:40:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>No changes and new features in version 1.11.0</strong></p>\n","latest_fixes_x_late":"<p><strong>Fixes included in version 1.11.0:</strong></p>\n\n<ul>\n\t<li><strong>The following issue has been fixed in Unified Extensible Firmware Interafce (UEFI) ROM:&nbsp;</strong>On some platforms, the hfi1 device was&nbsp;not showing up in BIOS/UEFI boot menus and was not&nbsp;available as a PXE boot device. This was caused by the platform not loading the UEFI driver for the hfi1 adapter.&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>No changes and new features in version 1.11.0</strong></p>\n","curr_fixes_x_late":"<p><strong>Fixes included in version 1.11.0:</strong></p>\n\n<ul>\n\t<li><strong>The following issue has been fixed in Unified Extensible Firmware Interafce (UEFI) ROM:&nbsp;</strong>On some platforms, the hfi1 device was&nbsp;not showing up in BIOS/UEFI boot menus and was not&nbsp;available as a PXE boot device. This was caused by the platform not loading the UEFI driver for the hfi1 adapter.&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"Intel_OPA_HFI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE, and EO0800JEFPF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5236659","datemodified":"2021-07-23T08:44:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/CP048183.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/HSSCPCD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-71af849f3b-HPD3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048183.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048183.scexe"],"md5sum":"395248938363c0c2e6ed37eba7d806a6","name":"firmware-hdd-71af849f3b-HPD3-8.1.x86_64.rpm","release":"2021-07-23T08:31:11","revision":"0","sha1sum":"c236ab583305d0cdf377e78aca5fc162dced4d4d","size":"4MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"5691df43dd354d538b509faabb482ba9","version":"74e69b2754494d7a918117cc6a87aa28"},"installation":{"command":"CP040260.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:47:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MK000480GWSSC、MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4459808","datemodified":"2021-07-25T20:57:22","file_list":["cp048654.xml","cpqsetup.exe","GSM883G3.rel","payload.json","setup.dll"],"md5sum":"e84d319cdd2d329efbea507d9544af0f","name":"cp048654.exe","release":"2021-07-25T20:49:04","revision":"0","sha1sum":"66f479ed48e2160f9b338cde87e2b0de85ecfbc5","size":"4MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"2a24f9ce00084650b7c1f83427a4e25f","version":"510b9d30680448ddb07494e1f9707bc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- MK000480GWSSC、 MK000960GWSSD、MK001920GWSSEおよびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T19:07:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":800,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added HPE Smart Array p824i-p controller support&nbsp;</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3619464","datemodified":"2021-09-01T10:55:38","file_list":["cp038106.xml","cpqsetup.exe","payload.json","setup.dll","TiogaPass-Release-1.00-build-000.bin.fw"],"md5sum":"aeab843cab92736ea4f93a6964822f9b","name":"cp038106.exe","release":"2021-09-01T10:43:09","revision":"0","sha1sum":"63fd399fe9ed6fdc89c95e71cbe804b0098004f2","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00"}],"id":{"product":"b6b93bd958d94fa882426d0e7804a97a","version":"a3f87c217e7842e49707db8c50667f74"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":800,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 2000  Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"},{"id":"Apollor2800Gen10","target_guid":"","type":"agp"},{"id":"Tioga Pass","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-24T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array p824i-p controller support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEFNAおよびMB6000GEFNBドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5321900","datemodified":"2021-07-23T07:21:24","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/CP048161.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/SMKRATG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-40277d55d3-HPG6-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048161.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048161.scexe"],"md5sum":"5c7396086f53ce4e1a52c3da1fac6760","name":"firmware-hdd-40277d55d3-HPG6-10.1.x86_64.rpm","release":"2021-07-23T07:07:14","revision":"0","sha1sum":"fe92f620e71ae3248ecf36a6a21a60a0da4d6f6e","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"72599cd140dd4be0b9dbc3875c332654","version":"92e9d3545345490aab5cef5c34fb1ed0"},"installation":{"command":"CP040261.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:10:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18782659","datemodified":"2021-08-30T20:20:47","file_list":["/CP048330_BUILD_2.data","/CP048330.vmexe","/CP048330.vmexe64","/CP048330.vmfile","/CP048330_VMw.zip","/CP048330.xml","/payload.json","/CP048330_VMw.zip/index.xml","/CP048330_VMw.zip/vendor-index.xml","/CP048330_VMw.zip/metadata.zip","/CP048330_VMw.zip/vib20/CP048330/HPE_bootbank_CP048330_HPD2.2-7.0.0.15843807.vib","/CP048330_VMw.zip/metadata.zip/vendor-index.xml","/CP048330_VMw.zip/metadata.zip/vmware.xml","/CP048330_VMw.zip/metadata.zip/vibs/CP048330--1759966185983670208.xml","/CP048330_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048330_HPD2.2-7.0.0.15843807.xml"],"md5sum":"7afc5c54b93c2fd06b07604ffa910143","name":"CP048330.zip","release":"2021-08-30T20:15:37","revision":"0","sha1sum":"37c64c0886d034c2d101f53b49be23f444ee25cb","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048330","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"3fba85b34f854c9b9b5bb51030ba5e41","version":"afbad0c53f54434bb2d7bbaec80475ea"},"installation":{"command":"CP041489.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000JWKGNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:35:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"2916032","datemodified":"2021-07-24T06:29:02","file_list":["cp048485.xml","cpqsetup.exe","payload.json","setup.dll","TA14SED8.rel"],"md5sum":"5b0193dec9cdb00625a63a2cb3ea5d8c","name":"cp048485.exe","release":"2021-07-24T06:21:05","revision":"0","sha1sum":"6fe52a075eefd3c3ca53e5272d99cacc181fb27d","size":"2MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"696ee1f3634445c49a160d3bc3772307","version":"6cec8bd277a941e9899b572a64f027f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0600JETKA、EG0900JETKB、およびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T07:49:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含適用於 HPE BladeSystem c-Class Virtual Connect 模組的韌體映像。此韌體提供 HPE BladeSystem c-Class Virtual Connect 模組的管理功能。此元件及其韌體可用於下列情況： 1) 搭配 BladeSystem 線上韌體套件中找到的 Smart Update Manager (智慧型更新管理器) 一起使用時，此元件可以用於部署韌體至 HPE BladeSystem c-Class Virtual Connect 模組；及 2) 從此元件解壓縮的韌體可使用 Virtual Connect Support Utility 部署至 HPE BladeSystem c-Class Virtual Connect 模組。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ko","x_late":"이 구성 요소에는 HPE 블레이드시스템 c-클래스 가상 연결 모듈용 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE 블레이드시스템 c-클래스 가상 연결 모듈에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 구성요소는 BladeSystem Online Firmware Bundle에서 확인된 Smart Update Manager와 함께 사용되어 HPE BladeSystem c-Class 가상 연결 모듈로 펌웨어를 배포할 수 있고, 2) HP BladeSystem c-Class 가상 연결 모듈용 가상 연결 지원 유틸리티를 통해 구성요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件可为 HPE BladeSystem c-Class Virtual Connect 模块提供固件镜像。该固件可为 HPE BladeSystem c-Class Virtual Connect 模块提供管理功能。该组件及其固件适用于以下情形： 1) 与在 HP BladeSystem 在线固件包上找到的HP智能升级管理器（Smart Update Manager）配合使用，此组件可用于将固件部署到 HPE C 系列刀片式系统虚拟连接（HP BladeSystem c-Class Virtual Connect）模块；2) 可通过适用于 HPE C 系列刀片式系统虚拟连接模块的虚拟连接支持实用程序（Virtual Connect Support Utility）部署从此组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Virtual Connectモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class Virtual Connectモジュールの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) HPE BladeSystem  c-Class Virtual Connectモジュールにファームウェアをインストールするために、Firmware Maintenance CD上あるいはHPE BladeSystem Online Firmware Bundle内にあるHPE Smart Update Managerと共同でコンポーネントを使用する 。および2) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Virtual ConnectモジュールのVirtual Connectサポートユーティリティを使用してインストールする。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257255528","datemodified":"2020-07-20T02:59:57","file_list":["Entry.bsh","HpsumCli.exe","PackageDesc.xml","cp043332.xml","cp_data.xml","vcfwall485.bin"],"md5sum":"ac1a8acba5c6cd1a98afe0631175fa88","name":"cp043332.exe","release":"2020-07-20T02:44:05","revision":"0","sha1sum":"a058bbcd7e479bf87711be8a579659f09f81a315","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"2720830f9ed94ee48b3be0778488e00f","version":"2d9971b9341e4bd8914f8b99847679ea"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85, HPE VC 8Gb 24-Port FC version&nbsp;4.20, HPE VC 16Gb 24-Port FC version 4.20,&nbsp;and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility&nbsp;release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 &nbsp;and then upgrade from VC 4.50 to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE&nbsp;VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Windows)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition  Component for Windows"},{"lang":"ko","x_late":"Windows용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Windows 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネントfor Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"466482-B21","target_guid":"","type":"other"},{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."},{"lang":"ja","x_late":"Agentless Management Service（AMSD）は、Integrated Lights Out 5（iLO 5）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2917885","datemodified":"2021-12-06T05:18:03","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqiScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"ac5fe8ebe171bb3a59b4978ff7743707","name":"amsd-2.6.0-1701.1.rhel7.x86_64.rpm","release":"2021-12-06T05:06:31","revision":"0","sha1sum":"bc5ad79ca0fe77159ed5cd6d954f03e946a5886b","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"2.6.0"}],"id":{"product":"f9f0f575f0ee448d89b3c55f9e30c251","version":"788fe63473674580b91614bf261395bc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<ul>\n\t<li>パッケージをインストールするには、次のようにタイプします。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-<version>.rpm</li>\n\t</ul>\n\t</li>\n\t<li>パッケージが正しくロードされているか、以下をタイプして確認します。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>以下のコマンドを実行してヘルプを参照してください。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for Red Hat Enterprise Linux 7 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T14:25:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>New support added to amsd:</p>\n\n<ul>\n\t<li>Enhance the direct-attached SATA Drive Status - smart Error&nbsp;and failed.</li>\n\t<li>Enhance the direct-attached SATA Drive Status under hot-plug and hot-remove.</li>\n\t<li>Provide the new OID, cpqIdeAtaDiskCapacityLowBytes and cpqIdeAtaDiskCapacityHighBytes for SATA HD capacity support:</li>\n\t<li>HPE Synergy 4610C 10/25Gb Ethernet Adapter.</li>\n\t<li>HPE FC HBA/SN1700E</li>\n\t<li>HPE DSP DSC-25/100 Ent/Cld 10/25/100Gb</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11312976","datemodified":"2022-03-08T14:24:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/CP051333.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/U41_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051333.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051333.scexe"],"md5sum":"112732ac5e28b4674adf981fd4a21db6","name":"firmware-system-u41-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-08T14:17:43","revision":"0","sha1sum":"827b5ad4aa27eee8025dd30967aa55117b802362","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"d36b5614c00b4d00b66a58209cc5bffb","version":"a4ae00f210b54964bef08253cb97d753"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML350 Gen10 (U41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-07T08:13:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Virtual Connect modules. This firmware provides management capabilities for the HPE BladeSystem c-Class Virtual Connect modules. This component and its firmware can be used in the following scenarios: 1) in conjunction with the Smart Update Manager found in the HPE BladeSystem Online Firmware Bundle, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect modules, and 2) firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules."},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class バーチャルコネクトモジュールのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Class バーチャルコネクトモジュールの管理機能を提供します。このコンポーネントとそのファームウェアは、次のシナリオで使用できます：1) コンポーネントをHPE BladeSystemオンラインファームウェアバンドルにあるSmart Update Managerとともに使用することで、ファームウェアをHPE BladeSystem c-Classバーチャルコネクトモジュールに実装できる、および2) コンポーネントから展開したファームウェアを、HPE BladeSystem c-Classバーチャルコネクトモジュール対応のバーチャルコネクトサポートユーティリティを使用して実装できる。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>The 4.85&nbsp;version of HPE Virtual Connect Release Notes can be found in the in the following URL:&nbsp;<a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"}],"files":[{"bytes":"257797526","datemodified":"2020-07-20T02:59:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/CP043331.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/HpsumCli","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/PackageDesc.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/cp_data.xml","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-vceth-4.85-1.1/vcfwall485.bin","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043331.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043331.scexe"],"md5sum":"a1b889c932cd07ff8ea69c6f1d27819a","name":"firmware-vceth-4.85-1.1.x86_64.rpm","release":"2020-07-20T02:42:05","revision":"0","sha1sum":"b846ba26deeafa3dfcc8c7ed593a26f18efa1cba","size":"245MB","target_guids":[],"type_of_change":"1","version":"4.85"}],"id":{"product":"f94dec5c06294dd898433cd8abf10b3a","version":"509893f2521f4f4595773fa96f988527"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":1500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This component and its firmware can be used in the following scenarios:</p>\n\n<ol>\n\t<li>\n\t<p>In conjunction with the Smart Update Manager found on the SPP, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Firmware extracted from the component can be deployed using the Virtual Connect Support Utility for the HPE BladeSystem c-Class Virtual Connect modules.</p>\n\t</li>\n</ol>\n\n<p><strong>Installation Notes for using the component with Smart Update Manager and SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of <a href=\"http://www.hpe.com/info/spp/download\">SPP</a>.</li>\n\t<li>Extract the contents of the SPP ISO, locate the directory, /usb, and run the hpusbkey.exe file.</li>\n\t<li>Place the SPP on a USB key using the USB Key Utility</li>\n\t<li>Place this version of the Virtual Connect firmware component in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same&nbsp;network as the HPE BladeSystem c-Class Virtual Connect module to be updated.</li>\n\t<li>Run &ldquo;launch_hpsum.bat/launch_hpsum.sh&rdquo; on the SPP from the USB key to launch the Smart Update Manager.</li>\n\t<li>Follow the GUI to install the firmware on the Virtual Connect module.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>\n\t<p>Extract the firmware binary out of the component.</p>\n\t</li>\n\t<li>\n\t<p>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Virtual Connect module.</p>\n\t</li>\n\t<li>\n\t<p>Start the Virtual Connect Support Utility and deploy the firmware.</p>\n\t</li>\n</ol>\n\n<p>HPE requires using the HPE BladeSystem c-Class Virtual Connect Support Utility version 1.15.0&nbsp;(or higher)&nbsp;to install the HPE VC FlexFabric-20/40 F8 version 4.85, HPE VC Flex-10/10D version&nbsp;4.85,&nbsp;HPE VC FlexFabric 10Gb/24-port version 4.85,&nbsp;HPE VC 8Gb 24-Port FC version 4.20, HPE VC 16Gb 24-Port FC version 4.20, and HPE VC 8Gb 20-Port FC version 2.25&nbsp;firmware. Please read the HPE BladeSystem c-Class Virtual Connect Support Utility release notes.<br />\n<br />\nPlease be advised of a serious issue that could cause network outage when upgrading directly from VC 2.xx release version to VC 4.85&nbsp;release in Multi-Enclosure environment. Please upgrade from VC 2.xx to VC 3.70 or VC 4.10 first and then upgrade from VC 3.70 or VC 4.10 to VC 4.50 then upgrade from VC 4.50&nbsp;to VC 4.85&nbsp;in a Multi-Enclosure setup.</p>\n\n<p>To update HPE VC 8Gb 24-Port FC module(s) from Virtual Connect firmware 4.31 or lower to Virtual Connect 4.85&nbsp;or higher, these module(s) must first be updated with either Virtual Connect firmware version 4.4x or version 4.50 (Recommended version is 4.50) before they can be updated with Virtual Connect 4.85&nbsp;or higher.</p>\n\n<p>The USB Key Utility is used to copy the SPP onto a portable USB key storage device.&nbsp; Please note that the latest version (v2.0.0.0)&nbsp;of the utility is now 64-bit only.&nbsp; If the 32-bit application is needed, please use version 1.8, however, this version will not work on an ISO image greater than 4GB.</p>\n\n<p><strong>Note: Please read the Important note section of the Release Notes for firmware upgrade instructions.</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"HPE BladeSystem c-Class Virtual Connect 韌體，乙太網路加上 8Gb 20 埠及 8/16Gb 24 埠 FC Edition 元件 (適用於 Linux)"},{"lang":"en","x_late":"HPE BladeSystem c-Class Virtual Connect Firmware, Ethernet plus 8Gb 20-port and 8/16Gb 24-port FC Edition Component for Linux"},{"lang":"ko","x_late":"Linux용 HPE BladeSystem c-Class Virtual Connect 펌웨어, Ethernet plus 8Gb 20포트 및 8/16Gb 24포트 FC Edition 구성 요소"},{"lang":"cn","x_late":"HPE BladeSystem c-Class 虚拟连接固件，适用于 Linux 的 Ethernet plus 8Gb 20 端口和 8/16Gb 24端口 FC Edition 组件"},{"lang":"ja","x_late":"HPE BladeSystem c-Class Virtual Connectファームウェア、Ethernet plus 8 Gb 20ポートおよび8/16 Gb 24ポートFC Editionコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"60000"},"supported_devices":[{"id":"572018-B21","target_guid":"","type":"other"},{"id":"539535-B21","target_guid":"","type":"other"},{"id":"466482-B21","target_guid":"","type":"other"},{"id":"638526-B21","target_guid":"","type":"other"},{"id":"691367-B21","target_guid":"","type":"other"},{"id":"751465-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-04-03T10:39:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The list of enhancements in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","latest_fixes_x_late":"<p>The list of issues resolved in 4.80&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n"},{"curr_enhancements_x_late":"<p>The list of enhancements in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","curr_fixes_x_late":"<p>The list of issues resolved in 4.85&nbsp;version can be found in the HPE Virtual Connect Release Notes at&nbsp;URL<strong>:&nbsp;</strong><a href=\"http://www.hpe.com/info/vc/manuals\">http://www.hpe.com/info/vc/manuals</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"vc8gb","sw_key_expectedpath":"firmware:vc8gb"},{"name":"vceth","sw_key_expectedpath":"firmware:vceth"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"18255377","datemodified":"2021-08-26T14:25:40","file_list":["/CP048337_BUILD_3.data","/CP048337.vmexe","/CP048337.vmexe64","/CP048337.vmfile","/CP048337_VMw.zip","/CP048337.xml","/payload.json","/CP048337_VMw.zip/index.xml","/CP048337_VMw.zip/vendor-index.xml","/CP048337_VMw.zip/metadata.zip","/CP048337_VMw.zip/vib20/CP048337/HPE_bootbank_CP048337_HPG2.3-7.0.0.15843807.vib","/CP048337_VMw.zip/metadata.zip/vendor-index.xml","/CP048337_VMw.zip/metadata.zip/vmware.xml","/CP048337_VMw.zip/metadata.zip/vibs/CP048337--184982332656156337.xml","/CP048337_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048337_HPG2.3-7.0.0.15843807.xml"],"md5sum":"9296018b20b707d5604420e990d3754d","name":"CP048337.zip","release":"2021-08-26T14:20:18","revision":"0","sha1sum":"d93ec5bfdecc21776eb5d42e3b395d3d40214bf4","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048337","version":"HPG2.3-7.0.0.15843807"}]}],"id":{"product":"3fa689b1e0c54064af40f5128fac0e5b","version":"00ae617d61484de4bc52202efa2001a4"},"installation":{"command":"CP041453.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T21:22:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2943304","datemodified":"2021-07-25T17:38:20","file_list":["cp048627.xml","cpqsetup.exe","payload.json","setup.dll","TAPM4VVEHPD5.rel"],"md5sum":"880c18deb383ebeb0a8778ae693f0463","name":"cp048627.exe","release":"2021-07-25T17:31:04","revision":"0","sha1sum":"271a59501ded6579161d5961b7026d518178fc6f","size":"2MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0d44f7068b8b4ccebd15e4e19fe5c5fa","version":"2f9b09e09468492891f4c391e61185e0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)-  MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWU、およびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:40:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"55626","datemodified":"2021-11-09T06:26:22","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/41","./usr/lib/.build-id/41/26f1aceeeb97e02ffec965b2825947493073a5","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"8e19e934eef8abd20005bb6c0dd77636","name":"kmod-hp-ixgbevf-4.13.3-1.rhel8u3.x86_64.rpm","release":"2021-11-09T06:19:14","revision":"0","sha1sum":"a97e9863e75181f2b1344c0f124903d75330fecb","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.13.3-1"},{"bytes":"55678","datemodified":"2021-11-09T06:27:30","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-ixgbevf","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/866d2f62cc56fe47fc69b3ca89afe81715728f","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"c026452a7e32edd143c88b442ab96387","name":"kmod-hp-ixgbevf-4.13.3-1.rhel8u4.x86_64.rpm","release":"2021-11-09T06:19:14","revision":"0","sha1sum":"1ef84a446df743088d5b4ca70823822365cfefbf","size":"54KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.13.3-1"}],"id":{"product":"30f1903e29c9444e8763652af6b41477","version":"c1e42bf11e26429dba766b5a79035907"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where potential memory leak</li>\n\t<li>This product addresses an issue where eXpress Data Path(XDP) frame size calculations.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3647216","datemodified":"2021-07-25T15:39:33","file_list":["cp048614.xml","cpqsetup.exe","HAHC8SDB.rel","payload.json","setup.dll"],"md5sum":"413ed7a08d8c83fb05cb40ec1c1f1c8c","name":"cp048614.exe","release":"2021-07-25T15:32:07","revision":"0","sha1sum":"5db5fdc5c4c5ba0b145a7a7f25ea309b4351f706","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"f8be51b7e24840dda7b3bf9d2b21fe22","version":"154e6fa21beb4c0782b8c6cb16b9c8dd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB6000JEQUV およびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:58:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JXLBA and MB018000JXLAU Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5088136","datemodified":"2021-08-11T18:51:25","file_list":["cp049254.xml","cpqsetup.exe","payload.json","setup.dll","WpariscASFD2.rel"],"md5sum":"58e2f8260ad5d1bd73d9b675123ccd63","name":"cp049254.exe","release":"2021-08-11T18:42:06","revision":"0","sha1sum":"69b8ed3f237714e4f1cd2960ea97843190953119","size":"4MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"d1880357890d41959529b109e2a869e4","version":"6c2bb0a2cb824640aedba2dca2fe0945"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T14:23:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"3006088","datemodified":"2021-12-07T04:44:41","file_list":["cp050186.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEe0HPD5.REL"],"md5sum":"7c49ab1e8348b53038e41ce2845f3210","name":"cp050186.exe","release":"2021-12-07T04:36:02","revision":"0","sha1sum":"8d54d47f46ae101ac6b5cd796aa61241c26aa426","size":"2MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"057a33153b064c9280dd7da9d3d5a47a","version":"bf366dcfe5f84d3aaea0dc1c991cddbf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:57:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7226425","datemodified":"2021-07-25T12:28:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/CP048240.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/GP1725b0HPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cea219e4b1-HPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048240.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048240.scexe"],"md5sum":"d29d79e2ba819321d76350864c1b7641","name":"firmware-hdd-cea219e4b1-HPK3-3.1.x86_64.rpm","release":"2021-07-25T12:16:05","revision":"0","sha1sum":"14542b73a0e999bbca93d7a90145ccd2e8092afb","size":"6MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"9548ad0612e149baa76eccbb5ce95cee","version":"4efb861776bf4c21afa5ed0fdfb7ce11"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T09:16:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1985784","datemodified":"2021-12-07T11:23:14","file_list":["cp050317.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"ec3404a2cfdb3c6027b6897aa46527fc","name":"cp050317.exe","release":"2021-12-07T11:09:04","revision":"0","sha1sum":"4ce36719636e26b2708b3e2e235241fc4b5ac925","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"19810cc433a442df903276a4b0c34598","version":"15a118e062eb4263a6ebacc2ded1258e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30117","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30040","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30042","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30102","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30047","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30116","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30052","type":"pci","ven":"15B3"},{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"101E","subdev":"0007","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30007","type":"pci","ven":"15B3"},{"dev":"101E","subdev":"0012","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30012","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue which incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue which prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWVMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b57564d54","Version":"HPK3"},{"DeviceName":"VO003840KWVMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b57564d55","Version":"HPK3"},{"DeviceName":"VO007680KWVMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1723b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b57564d56","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5390704","datemodified":"2021-07-24T09:22:08","file_list":["cp048462.xml","cpqsetup.exe","GP1723b0HPK3.rel","payload.json","setup.dll"],"md5sum":"383311c4a4f74cac9ef766c5bef7ecb1","name":"cp048462.exe","release":"2021-07-24T09:13:07","revision":"0","sha1sum":"ea55ae2340cfc42157ce5b248460d4375950b09f","size":"5MB","target_guids":["562340a5-304f-3130-3932-304b57564d54","562340a5-304f-3330-3834-304b57564d55","562340a5-304f-3730-3638-304b57564d56"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"8ffd589c0d3c4586b8af1c72d7c3699f","version":"0a613232b7434285907811ff06761a89"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWVMT, VO003840KWVMU, and VO007680KWVMV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KWVMT、VO003840KWVMU、およびVO007680KWVMVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO007680KWVMV","target_guid":"562340a5-304f-3730-3638-304b57564d56","type":"nvme"},{"id":"VO003840KWVMU","target_guid":"562340a5-304f-3330-3834-304b57564d55","type":"nvme"},{"id":"VO001920KWVMT","target_guid":"562340a5-304f-3130-3932-304b57564d54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T11:54:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KWVMV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KWVMU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWVMT","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO0400KEFJB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304f-3430-304b45464a42","Version":"HPK4"},{"DeviceName":"VO1200KEFJC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3230-304b45464a43","Version":"HPK4"},{"DeviceName":"VO2000KEFJD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-324f-3030-304b45464a44","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO0400KEFJB, VO1200KEFJC and VO2000KEFJD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC&nbsp;and VO2000KEFJD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>&nbsp;None</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16034982","datemodified":"2021-09-24T10:12:44","file_list":["/CP045719_BUILD_5.data","/CP045719.vmexe","/CP045719.vmexe64","/CP045719.vmfile","/CP045719_VMw.zip","/CP045719.xml","/payload.json","/CP045719_VMw.zip/index.xml","/CP045719_VMw.zip/vendor-index.xml","/CP045719_VMw.zip/metadata.zip","/CP045719_VMw.zip/vib20/CP045719/HPE_bootbank_CP045719_HPK4.5-7.0.0.15843807.vib","/CP045719_VMw.zip/metadata.zip/vendor-index.xml","/CP045719_VMw.zip/metadata.zip/vmware.xml","/CP045719_VMw.zip/metadata.zip/vibs/CP045719-6546131769518136308.xml","/CP045719_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045719_HPK4.5-7.0.0.15843807.xml"],"md5sum":"ace4741361ca00b443a4f7e710842cd0","name":"CP045719.zip","release":"2021-09-24T10:06:39","revision":"0","sha1sum":"590b053825c7fc3f5b989aac0b08e5e601d6759a","size":"15MB","target_guids":["002340a5-5600-304f-3430-304b45464a42","002340a5-5600-314f-3230-304b45464a43","002340a5-5600-324f-3030-304b45464a44"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045719","version":"HPK4.5-7.0.0.15843807"}]}],"id":{"product":"151b3249eb8946acb43e16f663033dfa","version":"a131cd14ac3f467598a1dc6a0c005449"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO0400KEFJB, VO1200KEFJC and VO2000KEFJD Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO0400KEFJB","target_guid":"002340a5-5600-304f-3430-304b45464a42","type":"nvme"},{"id":"VO1200KEFJC","target_guid":"002340a5-5600-314f-3230-304b45464a43","type":"nvme"},{"id":"VO2000KEFJD","target_guid":"002340a5-5600-324f-3030-304b45464a44","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:48:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO0400KEFJB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO1200KEFJC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO2000KEFJD","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"4416288","datemodified":"2022-02-08T13:17:04","file_list":["/cp049606.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/index.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vendor-index.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/sut-6.7.0.2.9.1.0-21.vib","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/ilo_670.10.7.5.2-1OEM.670.0.0.7535516.vib","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/sutesxcli-6.7.0.2.9.1.0-9.vib","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vendor-index.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vmware.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vibs/sut-7687720005944333592.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vibs/cru--1581854872647123919.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vibs/ilo-2964936189223017316.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/vibs/sutesxcli-602057286740537615.xml","/sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/metadata-sut-esxi6.7-offline-bundle-2.9.1.0-6.zip/bulletins/sut-esxi6.7-offline-bundle-2.9.1.0-6.xml"],"md5sum":"13a9218736128663254b6cfb2260061e","name":"cp049606.zip","release":"2022-02-08T13:15:02","revision":"0","sha1sum":"0cd60efb615982c2513507c8f14622e70144710d","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf680a7e2","20a6e8e4-bf33-4c71-a6bf-d9ece09b5689","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"sut","version":"6.7.0.2.9.1.0-21"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"},{"name":"ilo","version":"670.10.7.5.2-1OEM.670.0.0.7535516"},{"name":"sutesxcli","version":"6.7.0.2.9.1.0-9"}]}],"id":{"product":"af9477b9fa00462698ac47498ea633b5","version":"de32695330e4430e9c1cbe9284bbebd3"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v &lt;path&gt;&lt;filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-21T09:48:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sutesxcli:6.7.0.2.9.1.0-9","sw_key_expectedpath":"software:vmware:zip"},{"name":"sut:6.7.0.2.9.1.0-21","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:670.10.7.5.2-1OEM.670.0.0.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5492206","datemodified":"2021-08-20T07:13:55","file_list":["/CP046787_BUILD_16.data","/CP046787.vmexe","/CP046787.vmexe64","/CP046787.vmfile","/CP046787_VMw.zip","/CP046787.xml","/payload.json","/CP046787_VMw.zip/index.xml","/CP046787_VMw.zip/vendor-index.xml","/CP046787_VMw.zip/metadata.zip","/CP046787_VMw.zip/vib20/CP046787/HPE_bootbank_CP046787_2021.10.01.16-7.0.0.15843807.vib","/CP046787_VMw.zip/metadata.zip/vendor-index.xml","/CP046787_VMw.zip/metadata.zip/vmware.xml","/CP046787_VMw.zip/metadata.zip/vibs/CP046787-3747470126233001805.xml","/CP046787_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046787_2021.10.01.16-7.0.0.15843807.xml"],"md5sum":"1b6cad78826dc97d2252fbf5bd1f9f8c","name":"CP046787.zip","release":"2021-08-20T07:08:04","revision":"0","sha1sum":"f85a2b866f70e721271a98dde23842a49e3fa0f8","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046787","version":"2021.10.01.16-7.0.0.15843807"}]}],"id":{"product":"085dc91909144ecd8918a217072a43fb","version":"fb9e9d12c2a648799e7656024452a685"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Distributed Management Task Force (DMTF) &ndash; Platform Level Data Model (PLDM) Firmware Update to the SN1200E, SN1600E, and SN1610E</li>\n\t<li>The adapter will now reset to defaults when the user activates Hewlett Packard Enterprise (HPE) Secure Erase from Hewlett Packard Enterprise (HPE) intelligent provisioning</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior&nbsp;where the SN1600E would wrongly display an unwanted message when loading Unified Extensible Firmware Interface (UEFI) driver defaults</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1440264","datemodified":"2021-09-28T11:19:42","file_list":["cp047048.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"be4d1632f51ef2b82c60d15844701fe8","name":"cp047048.exe","release":"2021-09-28T11:05:42","revision":"0","sha1sum":"5182064078198081471ce18d1a4d562e5ff6a6c8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"ed78d2df04834204b8977e0aaa96c64a","version":"bff70374b8d640cb8caa328c46958d19"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel i40ebドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library i40ebmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40eb68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Windowsオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"21150968","datemodified":"2022-02-02T13:16:40","file_list":["cp050332.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"a2460971dc32b30caf3b0c85a33e6ed0","name":"cp050332.exe","release":"2022-02-02T13:15:19","revision":"0","sha1sum":"fdab32c6cc0e684d8cf21396b27b2f227f174f78","size":"20MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.0.6"}],"id":{"product":"a8ea930bfde1449ab4444eb61f65be31","version":"862cc55e478f47deb1b539dc4f296ccf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n [インストール]ボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T07:18:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1014:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1200:</strong></p>\n\n<p>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.31.1014:</strong></p>\n\n<p>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). Note: If the port does not go up, switch to Force mode.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li>\n\t<li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following device&nbsp;has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、 MO001600KWJSNおよびMO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;4ICDHPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16394300","datemodified":"2021-08-27T04:57:40","file_list":["/CP048471_BUILD_2.data","/CP048471.vmexe","/CP048471.vmexe64","/CP048471.vmfile","/CP048471_VMw.zip","/CP048471.xml","/payload.json","/CP048471_VMw.zip/index.xml","/CP048471_VMw.zip/vendor-index.xml","/CP048471_VMw.zip/metadata.zip","/CP048471_VMw.zip/vib20/CP048471/HPE_bootbank_CP048471_4ICDHPK1.2-7.0.0.15843807.vib","/CP048471_VMw.zip/metadata.zip/vendor-index.xml","/CP048471_VMw.zip/metadata.zip/vmware.xml","/CP048471_VMw.zip/metadata.zip/vibs/CP048471--7735200043338282656.xml","/CP048471_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048471_4ICDHPK1.2-7.0.0.15843807.xml"],"md5sum":"3f5ba298fefa71768327fa3c2a224ab5","name":"CP048471.zip","release":"2021-08-27T04:52:13","revision":"0","sha1sum":"94c342d01b42b53837a1718340146bdbad0e837d","size":"15MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1","vib_list":[{"name":"CP048471","version":"4ICDHPK1.2-7.0.0.15843807"}]}],"id":{"product":"180a7c20ed0347b4a9c066f5e5cf116b","version":"34f4d91da4cb493596a44fb1ce39ac1b"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T16:01:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows - HPE Apollo 2000 Gen10 Plusバックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     NA<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     NA<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     NA<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>最初のリリース</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点:</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"3659384","datemodified":"2021-09-01T11:25:02","file_list":["Capitola-Release-1.27.bin.fw","cp049338.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"1e281ee60c0d4b3a8ec30bdcf3a00783","name":"cp049338.exe","release":"2021-09-01T11:08:10","revision":"0","sha1sum":"a921277c9c89183a5046175885f3fc576392a39f","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"id":{"product":"e79fad26938d4b788f99ac1b9d5aa529","version":"4c9c1b540b044f16a3082e80e0e5519a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<p> </p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-24T06:01:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added Win2022 support</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"}],"files":[{"bytes":"362271","datemodified":"2020-02-05T16:25:34","file_list":["/cp042920.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/elxnet-12.0.1216.4-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/README.txt","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.7.0-elxnet-12.0.1216.4-13017494.zip/VMW-ESX-6.7.0-elxnet-12.0.1216.4-offline_bundle-13017494.zip/metadata.zip/vibs/elxnet--1134262900.xml"],"md5sum":"e0737390f016bd44de695feeb0de64b6","name":"cp042920.zip","release":"2020-02-05T22:24:05","revision":"0","sha1sum":"4940baedcb79e6d8886a99270224cb15d7bcb658","size":"353KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.03.09","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.670.0.0.8169922"}]}],"id":{"product":"e420d2824f1a4f3980b18730d5e2bcc4","version":"3b510f5dfbf04414b2ce803a4d0454fe"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-03-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects&nbsp;a vmnic flapping issue which impacts network&nbsp;connectivity.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"121412","datemodified":"2021-11-05T03:03:33","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/89","./usr/lib/.build-id/89/294d823b6a9ed4172130d163a0b074a02de739","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"be042693c1798f53324a4b45947b7b5f","name":"kmod-hp-igb-6.8.5-2.rhel8u3.x86_64.rpm","release":"2021-11-05T02:56:57","revision":"0","sha1sum":"ee91ae10353c89c8a378844fc4d017bf819c4081","size":"118KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.8.5-2"},{"bytes":"121639","datemodified":"2021-11-05T03:07:50","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-igb","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/5a","./usr/lib/.build-id/5a/62e61643a1dbce26e84060b3f8e4bbb1ed06a0","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"5cf42fecddc0730318e207d64f358b90","name":"kmod-hp-igb-6.8.5-2.rhel8u4.x86_64.rpm","release":"2021-11-05T02:56:57","revision":"0","sha1sum":"7a74a9f2d34c7156de61272e77563920510fbc6c","size":"118KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.8.5-2"}],"id":{"product":"eb361011be5348dc81ccf25ec5c94210","version":"e7d4a6e1d0384f9592d8cf31f9468cb4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-05T01:47:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Linux Firmware upgrade utility v.1.22.5</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 4</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXF"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>&nbsp;85031G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n      オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ<br />\n <br />\n<strong>リリースバージョンおよび/または日付：<br />\n      </strong>85032G00</p>\n\n<p><strong>最新の推奨またはクリティカルバージョン：</strong><br />\n      85031G00</p>\n\n<p><strong>前のファームウェアバージョン：<br />\n     </strong> 85031G00</p>\n\n<p><strong>ファームウェアの依存関係:<br />\n      </strong>なし  </p>\n\n<p><strong>改善点/新しい機能： </strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題:</strong></p>\n\n<ul>\n\t<li>FWベースのVPDを実装します。</li>\n\t<li>ARP設定を\"Capable & Discoverable\"から\"Fixed & Discoverable\"に変更しました。</li>\n\t<li>重要な変数が適切に初期化されるように、フォアグラウンドメディアスキャン（FMS）アルゴリズムを微調整しました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong></p>\n\n<ul>\n\t<li>iLO5 v2.30以降が必要です。SUMは、v2.30より前のバージョンのiLOを使用した展開のファームウェアアップデートに適用可能としてSSDを検出しません</li>\n</ul>\n"}],"files":[{"bytes":"5708928","datemodified":"2021-12-02T11:58:15","file_list":["85032G00_mp.bin","cp050167.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"md5sum":"3c83f30f0e5dc1f8e0dc78fb0034d05a","name":"cp050167.exe","release":"2021-12-02T11:52:01","revision":"0","sha1sum":"3a80d8285bc8d0cc3525a2d52d57837ae870255b","size":"5MB","target_guids":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"type_of_change":"1","version":"85032G00"}],"id":{"product":"15c5494e659e4865b78e60077bae7860","version":"98479c4e14014853b370ddb2eee00d0b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em>&nbsp;script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T02:47:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp; &nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3198104","datemodified":"2021-07-26T06:30:44","file_list":["cp048466.xml","cpqsetup.exe","GPM1643ASAD4.rel","payload.json","setup.dll"],"md5sum":"c7b423ef001ddfd3729f4a969ae43b0b","name":"cp048466.exe","release":"2021-07-26T06:23:05","revision":"0","sha1sum":"b90bfe0f439e1853d9d75eccaba04c64ae577a71","size":"3MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e5d8389759aa4832a8475a2ff763f16b","version":"d7fcf5ecbebc4858aba47c20e26a207c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:05:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp; &nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17460050","datemodified":"2021-08-30T04:59:58","file_list":["/CP048261_BUILD_3.data","/CP048261.vmexe","/CP048261.vmexe64","/CP048261.vmfile","/CP048261_VMw.zip","/CP048261.xml","/payload.json","/CP048261_VMw.zip/index.xml","/CP048261_VMw.zip/vendor-index.xml","/CP048261_VMw.zip/metadata.zip","/CP048261_VMw.zip/vib20/CP048261/HPE_bootbank_CP048261_HPD5.3-7.0.0.15843807.vib","/CP048261_VMw.zip/metadata.zip/vendor-index.xml","/CP048261_VMw.zip/metadata.zip/vmware.xml","/CP048261_VMw.zip/metadata.zip/vibs/CP048261--2674799031549723175.xml","/CP048261_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048261_HPD5.3-7.0.0.15843807.xml"],"md5sum":"febe461b93f3e5e2bc7572c948a2a37f","name":"CP048261.zip","release":"2021-08-30T04:54:40","revision":"0","sha1sum":"fd299a22bd2fd24016532967700827f08370d7ec","size":"16MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048261","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"d480050a16674bf2aaea0c812270030a","version":"4189c7a5066d423e89a55e7032d92820"},"installation":{"command":"CP042538.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T09:54:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2031667","datemodified":"2021-11-02T22:17:50","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"833bed8b6418f2b27312a575aa5025df","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.sles15sp2.x86_64.rpm","release":"2021-11-02T21:08:05","revision":"0","sha1sum":"43f8366739dabd11cf1878f8353fe0170a94aabd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"1996893","datemodified":"2021-11-02T22:20:50","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"1e45951b0026dc18c9ad08528101554e","name":"mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.4.0.8.1.sles15sp2.x86_64.rpm","release":"2021-11-02T21:08:05","revision":"0","sha1sum":"eea6d6fd27d9fccc8e74748615463ef54aee6f75","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"7af26f11b3bd4a2f99d0fd0dcc72a2db","version":"76895ee9e71941a39be2be66dcdcad3e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using &nbsp;5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"},{"lang":"ja","x_late":"<p>rootとしてログインし、rpmをご使用のハードディスク上のディレクトリにダウンロードし、そのディレクトリに移動します。<br />\n<br />\n<strong>注記</strong>：RoCEのユーザースペース機能を有効にするために、使用されているカーネルバージョンやタイプにかかわらず、\"mlnx-ofa_kernel-4.9\" RPMをインストールする必要があります。RoCEのユーザースペースライブラリであるRPM（mlnx-ofa_kernel）はOS配布に含まれるOpenMPI RPMと競合することがあります。これは既知の挙動です。Linux分布からのOpenMPI RPMは\"mlnx-ofa_kernel\"のインストレーションの前にはターゲットのノードにインストールされないことに注意が必要です。もし既にインストールされていれば、 HPE Mellanox RoCEのドライバーパッケージをインストールする前にすべてのOpenMPI配布のRPMをアンインストールしてください。<br />\n<br />\nドライバーをインストールまたはアップグレードするには次のようにします。<br />\n5.3.18-22-defaultカーネルまたは任意の将来のerrataを使用する場合：<br />\n<br />\n<strong># rpm -Uvh mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_22-OFED.4.9.3.1.6.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nセットアップは完了しました。ドライバーを有効にするにはコンピューターを再起動します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Agentless Management Smart Component for ESXi 7.0 includes the latest HPE Agentless Management Service (AMS), and AMS ESXCLI Interface."},{"lang":"ja","x_late":"HPE ESXi Agentless Management Smartコンポーネント for ESXi 7.0には、最新のHPE Agentless Management Service (AMS）、およびAMS ESXCLIインターフェイスが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"715073","datemodified":"2021-09-11T08:26:04","file_list":["/cp047520.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip","/amsdComponent_701.11.8.0.15-1_18612107.zip/index.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip/vendor-index.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip/metadata.zip","/amsdComponent_701.11.8.0.15-1_18612107.zip/vib20/amsd/HPE_bootbank_amsd_701.11.8.0.15-1OEM.701.0.0.16850804.vib","/amsdComponent_701.11.8.0.15-1_18612107.zip/metadata.zip/vendor-index.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip/metadata.zip/vmware.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip/metadata.zip/vibs/amsd--8214859305018519733.xml","/amsdComponent_701.11.8.0.15-1_18612107.zip/metadata.zip/bulletins/amsdComponent_701.11.8.0.15-1.xml"],"md5sum":"a30fd913203e90895aa9db4314f3cfd2","name":"cp047520.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"a4ddb106c4b3f077de813d2cc08d8d49100eaf46","size":"698KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"amsd","version":"701.11.8.0.15-1OEM.701.0.0.16850804"}]}],"id":{"product":"5588a72e9c0d4878a499b54f0c18241c","version":"dc5457c7262a48a6af3ec140a73ec079"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip the&nbsp;HPE smart&nbsp;component zip file to extract the driver offline bundle&nbsp;zip file.</li>\n\t<li>Copy the driver offline bundle zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルのzipファイルを抽出するために、HPE Smartコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーオフラインバンドルのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Agentless Management Bundle Smart Component on ESXi 7.0 for Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"HPE Agentless ManagementバンドルSmartコンポーネントon ESXi 7.0 for Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"700"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-11-28T02:20:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"amsdComponent:701.11.8.0.15-1","sw_key_expectedpath":"software.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"5569352","datemodified":"2021-07-23T08:16:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/CP048090.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/HKFL4CD7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f3faa195ff-HPD7-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048090.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048090.scexe"],"md5sum":"5912bd1fc0c002633cb23769263dd7f1","name":"firmware-hdd-f3faa195ff-HPD7-8.1.x86_64.rpm","release":"2021-07-23T08:03:20","revision":"0","sha1sum":"0d1f27a09f5c45c663fa19ed3199df7e43cbb3e0","size":"5MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"dc8e1d549b6c46c4a9bd046b4dd1950e","version":"0f3cda86587e4bed849bb4f9006f7f81"},"installation":{"command":"CP040340.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:44:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWEBHおよびEG000300JWEBF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17505193","datemodified":"2021-08-30T07:45:07","file_list":["/CP049345_BUILD_3.data","/CP049345.vmexe","/CP049345.vmexe64","/CP049345.vmfile","/CP049345_VMw.zip","/CP049345.xml","/payload.json","/CP049345_VMw.zip/index.xml","/CP049345_VMw.zip/vendor-index.xml","/CP049345_VMw.zip/metadata.zip","/CP049345_VMw.zip/vib20/CP049345/HPE_bootbank_CP049345_HPD5.3-7.0.0.15843807.vib","/CP049345_VMw.zip/metadata.zip/vendor-index.xml","/CP049345_VMw.zip/metadata.zip/vmware.xml","/CP049345_VMw.zip/metadata.zip/vibs/CP049345-2934946384033608441.xml","/CP049345_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049345_HPD5.3-7.0.0.15843807.xml"],"md5sum":"78ef42c11d6ca7bbbc54e9c2072dff12","name":"CP049345.zip","release":"2021-08-30T07:40:03","revision":"0","sha1sum":"6f13ecb6d9ab1fb83671f56521ebc9c6d9456019","size":"16MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP049345","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"2fe8cdf1119641378a716d37c5e433f7","version":"3a76ed3bdd304961937a09e1718b779f"},"installation":{"command":"CP040661.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:41:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16230792","datemodified":"2021-08-27T13:25:28","file_list":["/CP048447_BUILD_2.data","/CP048447.vmexe","/CP048447.vmexe64","/CP048447.vmfile","/CP048447_VMw.zip","/CP048447.xml","/payload.json","/CP048447_VMw.zip/index.xml","/CP048447_VMw.zip/vendor-index.xml","/CP048447_VMw.zip/metadata.zip","/CP048447_VMw.zip/vib20/CP048447/HPE_bootbank_CP048447_HPG4.2-7.0.0.15843807.vib","/CP048447_VMw.zip/metadata.zip/vendor-index.xml","/CP048447_VMw.zip/metadata.zip/vmware.xml","/CP048447_VMw.zip/metadata.zip/vibs/CP048447-6076430416749615820.xml","/CP048447_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048447_HPG4.2-7.0.0.15843807.xml"],"md5sum":"62630d1715a9ee83e30bec5522a0c9ad","name":"CP048447.zip","release":"2021-08-27T13:20:44","revision":"0","sha1sum":"9f852d979ee417ad86003a74350519a73fbb98cc","size":"15MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048447","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"1cadb74f384743de9dfa8d9d6bc9f7b5","version":"415899c6be624816abdd4d41ab75b563"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:28:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5415019","datemodified":"2021-07-23T08:15:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/CP048089.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/SVKBPND4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8c4a212ff9-HPD4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048089.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048089.scexe"],"md5sum":"48809f678313c94ca16424804a84e88d","name":"firmware-hdd-8c4a212ff9-HPD4-9.1.x86_64.rpm","release":"2021-07-23T08:03:23","revision":"0","sha1sum":"aa19f57ea616e766cd69db5df482e678e7bce4ce","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"62bd64385d4642c4adfd6fdae64666cb","version":"a42a36e975974b6e9adef119d042b34e"},"installation":{"command":"CP040263.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:37:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4906849","datemodified":"2021-07-23T08:24:15","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/CP048082.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/T14SEED8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7fc5497116-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048082.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048082.scexe"],"md5sum":"4e401886fa3101cfbe0fff095353c52e","name":"firmware-hdd-7fc5497116-HPD8-2.1.x86_64.rpm","release":"2021-07-23T08:12:05","revision":"0","sha1sum":"0eb3642989662c23c97ff5797debb5267cea5497","size":"4MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"07f321e61ae446eba28c1b93476d5170","version":"c08069df7aa44afdbd2d5d82a876c683"},"installation":{"command":"CP040318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:05:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34210568","datemodified":"2022-02-07T07:32:24","file_list":["cp050612.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U46_1.58_01_13_2022.signed.flash"],"md5sum":"166b2312486a8f81b48c96209d705912","name":"cp050612.exe","release":"2022-02-07T07:30:11","revision":"0","sha1sum":"351e5458b642683169c14d2b56621eb25a2038f8","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"1f3d9896fbab4dc5aed295b2183323a0","version":"96131d02a06d4f9f8f1edb81b202a633"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-22T03:06:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"U46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEMDB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17741677","datemodified":"2021-08-30T05:54:01","file_list":["/CP048266_BUILD_4.data","/CP048266.vmexe","/CP048266.vmexe64","/CP048266.vmfile","/CP048266_VMw.zip","/CP048266.xml","/payload.json","/CP048266_VMw.zip/index.xml","/CP048266_VMw.zip/vendor-index.xml","/CP048266_VMw.zip/metadata.zip","/CP048266_VMw.zip/vib20/CP048266/HPE_bootbank_CP048266_HPD5.4-7.0.0.15843807.vib","/CP048266_VMw.zip/metadata.zip/vendor-index.xml","/CP048266_VMw.zip/metadata.zip/vmware.xml","/CP048266_VMw.zip/metadata.zip/vibs/CP048266-3589537419090905739.xml","/CP048266_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048266_HPD5.4-7.0.0.15843807.xml"],"md5sum":"9b9567d5046cf7d978d6189ab1c399c8","name":"CP048266.zip","release":"2021-08-30T05:48:46","revision":"0","sha1sum":"7396785ec0365ab9e2ce64586e779c98ebd6afd3","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048266","version":"HPD5.4-7.0.0.15843807"}]}],"id":{"product":"8881b9f92866499daac317541d2299ed","version":"1e7f7b92dd0b48acbb207d7d4fa53658"},"installation":{"command":"CP040573.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T12:54:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバーをアップデートします "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6933168","datemodified":"2022-02-21T02:10:42","file_list":["cp051154.compsig","cp051154.zip","cp051155.compsig","cp051155.zip","cp051158.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"74735d1eb366e0bae1fb65438df3e7a0","name":"cp051158.exe","release":"2022-02-21T02:09:24","revision":"0","sha1sum":"659fe84bba863c411b9247242b331e20fcc1cac8","size":"6MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.3.0"}],"id":{"product":"effc199f67764de3b570f964be1aa0ce","version":"9a7068e792d644edadcb2cff293e1551"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.<br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。<br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-21T02:05:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Address an issue where Innovation Engine (IE) Firmware may be unresponsive and iLO Firmware may report &ldquo;Update Failed&rdquo; after flashing the Innovation Engine (IE) Firmware via RESTful update. &nbsp;The flash will have been performed successfully, but the system must be reset for IE Firmware to function properly.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"ac963eeb-ed78-4f36-8cc1-29d85f34a0ac","Devices":{"Device":[{"DeviceName":"Firmware for HPE 16GB NVDIMM DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp032704.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-80ad-80ad80ad80ad","Version":"1.04"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This Linux component provides firmware upgrade for HPE 16GB NVDIMM-N DDR4-2666 Modules."},{"lang":"ja","x_late":"このLinuxコンポーネントは、HPE 16GB NVDIMM-N DDR4-2666モジュール用のファームウェアアップグレードを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Support list :</p>\n\n<p>Linux:</p>\n\n<ul>\n\t<li>SLES15 SP3</li>\n\t<li>SLES15 SP2</li>\n\t<li>SLES12 SP5</li>\n\t<li>RHEL 8.4</li>\n\t<li>RHEL 8.3</li>\n\t<li>RHEL 7.9</li>\n\t<li>RHEL 7.8</li>\n</ul>\n\n<p>VMWare:</p>\n\n<ul>\n\t<li>ESXi 7.0 U3</li>\n\t<li>ESXi 6.7 U2, U3</li>\n\t<li>ESXi 6.5&nbsp;U3</li>\n</ul>\n"}],"files":[{"bytes":"293476","datemodified":"2021-06-15T03:18:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/CP048326.xml","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/cp032704.compsig","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/cp032704.zip","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-1.04-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048326.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048326.scexe"],"md5sum":"75e3eb31a06e6bb5749256f91ce0e667","name":"firmware-nvdimm-16gb-1.04-3.1.x86_64.rpm","release":"2021-06-15T03:10:05","revision":"0","sha1sum":"f78dc7bfe8343aa3fcc9466b46e7bbbd6fdae114","size":"286KB","target_guids":["805dd01c-eb5a-1e76-80ad-80ad80ad80ad"],"type_of_change":"0","version":"1.04"}],"id":{"product":"5a879ce939db4665afe30df0d13ef686","version":"a4c7ea39c0d844ca8f7a004ecdf226ae"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command: rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP048326.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-nvdimm-16gb-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP048326.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;# ./hpsetup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-nvdimm-16gb-*&#39; location and run ./hpsetup to update the firmware. The actual name of the &#39;firmware-nvdimm-16gb-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HP Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\"><u>Service Pack for ProLiant&nbsp;</u></a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\" style=\"color: blue; text-decoration-line: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow HP Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /hp/swpackages</li>\n\t<li>Locate Start.html which is found in the root of the ISO</li>\n\t<li>Open the html file in a supported browser</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - 16GB NVDIMM-N DDR4-2666"},{"lang":"ja","x_late":"Linux用オンラインフラッシュコンポーネント - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T02:08:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>Initial release.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Add RHEL8.4 support.</li>\n\t<li>Add SLES15 SP3&nbsp;support.</li>\n\t<li>Add VMWare&nbsp;ESXi 7.0&nbsp;U3 support.</li>\n\t<li>Add VMWare&nbsp;vSphere 6.5&nbsp;U3 support.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD1"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD1"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD1"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ<br />\n<br />\n<strong>リリースバージョンおよび/または日付：</strong><br />\n      HPD1<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n      なし<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n       なし<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n      なし  </p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"17859218","datemodified":"2021-12-20T11:56:57","file_list":["/CP050453_BUILD_3.data","/CP050453.vmexe","/CP050453.vmexe64","/CP050453.vmfile","/CP050453_VMw.zip","/CP050453.xml","/payload.json","/CP050453_VMw.zip/index.xml","/CP050453_VMw.zip/vendor-index.xml","/CP050453_VMw.zip/metadata.zip","/CP050453_VMw.zip/vib20/CP050453/HPE_bootbank_CP050453_HPD1.3-7.0.0.15843807.vib","/CP050453_VMw.zip/metadata.zip/vendor-index.xml","/CP050453_VMw.zip/metadata.zip/vmware.xml","/CP050453_VMw.zip/metadata.zip/vibs/CP050453--7935474397955525415.xml","/CP050453_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050453_HPD1.3-7.0.0.15843807.xml"],"md5sum":"e2e8b9b9236097c440a8fe9c19139f54","name":"CP050453.zip","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"6708bc440295cd18b50c2dd40f0ae4f9815d9ebb","size":"17MB","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP050453","version":"HPD1.3-7.0.0.15843807"}]}],"id":{"product":"423cc31f15944616b9452d63683a53fd","version":"81cf241d9e1e4633a1777840d7396080"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6.7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO003840XZCLT","target_guid":"562340a5-304f-3330-3834-30585a434c54","type":"sas"},{"id":"MO001600XZCLV","target_guid":"4d2340a5-304f-3130-3630-30585a434c56","type":"sas"},{"id":"MO000800XZCLQ","target_guid":"4d2340a5-304f-3030-3830-30585a434c51","type":"sas"},{"id":"VO007680XZCMB","target_guid":"562340a5-304f-3730-3638-30585a434d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T10:56:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840XZCLT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600XZCLV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800XZCLQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680XZCMB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2000120","datemodified":"2021-12-07T12:50:30","file_list":["cp050319.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"9498e936a4b4ec6b4d4fbd115f46a6b6","name":"cp050319.exe","release":"2021-12-07T12:35:06","revision":"0","sha1sum":"571cbb286f4cacc3e4614d022c7fc36f46fb438a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"ed4e13cf761c496aa2355b8c9f267dd3","version":"eb993e8f971a42b59702731ba7868f00"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2016"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue where incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue where prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR100/Ethernet 100Gb 2ポートMCX653106A-ECAT QSFP56 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter(P23666-B21)</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000453</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2ポートMCX653106A-ECAT QSFP56 x16アダプター（P23666-B21）</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000453</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"5952245","datemodified":"2021-12-07T09:49:29","file_list":["20_32_1010-MCX653106A-ECA_HPE_Ax.pldm.signed","20_32_1010-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"db3df280f5fb9578f330d1efcdc7af93","name":"20_32_1010-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:46:39","revision":"0","sha1sum":"c1846e4e8c79c549b776444f14e40349378c903e","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"6ca4dd262131408db10af90451555128","version":"a2b6030190794c418f46021ae7dcbd44"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR100/Ethernet 100Gb 2ポートMCX653106A-ECAT QSFP56 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6007464","datemodified":"2021-07-23T07:32:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/CP048133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/HVLPeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048133.scexe"],"md5sum":"7ba59349f05697deeaba36b4bbb919b0","name":"firmware-hdd-82894b9e0a-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:18:06","revision":"0","sha1sum":"08bc553b5aacf197b769845161e004d51aacdacc","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d7cf155e76584b1f8fb8e3c7c222c90d","version":"ed16ae0c0cf24cfd9bdf3a9695fdfdb7"},"installation":{"command":"CP041482.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000GWRTC ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:44:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.19.51"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UMP, NCSI, and CCM code running under Windows Server 2019 and Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":null}],"files":[{"bytes":"5065056","datemodified":"2021-12-13T06:02:57","file_list":["bcmnicfwupg.exe","BMAPIa.dll","cp050426.xml","cpqsetup.exe","FW/","FW/330i-2x1G-14E4-1665-103C-22BD.BIN","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"7651054b3721cd2161862f72bac3aee5","name":"cp050426.exe","release":"2021-12-13T05:52:36","revision":"0","sha1sum":"4cdbc1c91fc53d53d3c8e000d9334ff47f90f44f","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"C9279","version":"d9a4a38067a94d21a1e2c59c30297351"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"214.0.0.0","description":"HPE Broadcom NX1 1Gb Driver version 214.0.0.0 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T08:56:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue about lost connection under S5 if adapter was running under 1G.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BcmNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This smart component contains the HPE Lights-Out Online Configuration Utility which is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the operating system without requiring a reboot of the server."},{"lang":"ja","x_late":"このSmartコンポーネントには、サーバーを再起動しないでオペレーティングシステムからProLiant Integrated Lights-Out（iLO）プロセッサーを設定するために使用するコマンドラインユーティリティである、HPE Lights-Outオンライン設定ユーティリティが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"1262136","datemodified":"2021-08-12T07:59:17","file_list":["cp048230.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"md5sum":"7094d70389dad468d53a47502d6dbbf3","name":"cp048230.exe","release":"2021-08-12T07:50:08","revision":"0","sha1sum":"16dd1f510f1d345a7e2504393634e6744a855b88","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"type_of_change":"0","version":"5.5.0.0"}],"id":{"product":"C9113","version":"a7d860131cb8402c9d326791836d04be"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":28,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Uninstall any older version of HPONCFG before installing this version of HPONCFG.</p>\n\n<p>Place Component to a directory in a temporary directory on your hard drive. Double-click it to run.</p>\n\n<p>Click on the install button to install the utlility on the server. This does not require a reboot.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>The utility will be installed in the program files under the directory HewlettPackardEnterprise\\HPONCFG\\</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p>A shortcut for the graphical interface of the utility will be provided in &quot;Start Menu &gt; Programs &gt; HPE System Tools &gt; HPE Lights-Out Online Configuration Utility&quot;.</p>\n"},{"lang":"ja","x_late":"<p>HPONCFGのこのバージョンをインストールする前に、HPONCFGのすべての古いバージョンをアンインストールします。</p>\n\n<p>コンポーネントを、ご使用のハードドライブの一時ディレクトリ内のディレクトリに置きます。ダブルクリックして実行します。</p>\n\n<p>インストールボタンをクリックし、サーバーにユーティリティをインストールします。再起動は必要ありません。</p>\n\n<p> </p>\n\n<p> </p>\n\n<p>ユーティリティは、HewlettPackardEnterprise\\HPONCFG\\ディレクトリの下にあるprogram filesにインストールされます</p>\n\n<p> </p>\n\n<p> </p>\n\n<p>ユーティリティのグラフィカルインターフェイス用のショートカットが、スタートメニュー >プログラム > HPEシステムツール > HPE Lights-Outオンライン構成ユーティリティに提供されます。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions"},{"lang":"ja","x_late":"HPE Lights-Out オンライン構成ユーティリティfor Windows x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"160"},"supported_devices":[{"dev":"B204","subdev":"B206","subven":"0E11","target_guid":"a6b1a447-382a-5a4f-0e11-b2040e11b206","type":"pci","ven":"0E11"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Storage Server 2008 x64 Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T05:08:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed an issue were HPONCFG failing on Microsoft Windows Server 2012 and 2012 R2&nbsp;with iLO in CNSA mode.</p>\n"},{"curr_enhancements_x_late":"<p>Introduced support for&nbsp;Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"","value":"HP StorageWorks 600 All-in-One Storage System"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"","value":"HP StorageWorks 1200 All-in-One Storage System"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"W04","value":"HP ProLiant DL320s Storage Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"I15","value":"HP ProLiant BL460c Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P64","value":"HP ProLiant DL360 G6 Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hponcfg.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 7.0 and for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE SmartアレイおよびSmart RAIDコントローラードライバーコンポーネントfor VMware vSphere 7.0。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"185103","datemodified":"2021-08-10T22:04:23","file_list":["/cp047416.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/index.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/vendor-index.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/metadata.zip","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/vib20/smartpqi/MIS_bootbank_smartpqi_70.4150.0.119-1OEM.700.1.0.15843807.vib","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/metadata.zip/vibs/smartpqi-5031768207965202989.xml","/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807_18380949.zip/metadata.zip/bulletins/Microchip-smartpqi_70.4150.0.119-1OEM.700.1.0.15843807.xml"],"md5sum":"fc7d424c12937bc4b0132d80dd653128","name":"cp047416.zip","release":"2021-10-05T00:00:00","revision":"1","sha1sum":"30c3e8073c81f2613f5ffcc910ca1b8e6f0ed4d2","size":"180KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"smartpqi","version":"70.4150.0.119-1OEM.700.1.0.15843807"}]}],"id":{"product":"e98331a0655643fe8e27ef6b9d441162","version":"db204ac1bf7e4a7887731405f2d47ed5"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 Smart Array and Gen10 Plus Smart RAID Controller Driver for VMware vSphere 7.0 (Driver Component)."},{"lang":"ja","x_late":"HPE ProLiant Gen10 SmartアレイおよびGen10 Plus Smart RAIDコントローラードライバーfor VMware vSphere 7.0（ドライバーコンポーネント）。"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-29T04:48:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A PSOD issue when system is running MBT Tool</li>\n\t<li>Fixed an issue where OS boot may fail during logical volume rebuild.</li>\n\t<li>Fixed an issue where logical disks are not exposed to OS.</li>\n\t<li>Fixed an issue with log spew during device resets.</li>\n\t<li>A PSOD issue with Task Management Function handler</li>\n\t<li>Fixed an issue where vSAN logs were showing higher latency for physical disks.</li>\n\t<li>Fixed an issue to avoid failing IOs for devices which are offline.</li>\n\t<li>Fixed an issue where error messages were printed for ignorable errors.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>A PSOD issue when system is running MBT Tool</li>\n\t<li>Fixed an issue where OS boot may fail during logical volume rebuild.</li>\n\t<li>Fixed an issue where logical disks are not exposed to OS.</li>\n\t<li>Fixed an issue with log spew during device resets.</li>\n\t<li>A PSOD issue with Task Management Function handler</li>\n\t<li>Fixed an issue where vSAN logs were showing higher latency for physical disks.</li>\n\t<li>Fixed an issue to avoid failing IOs for devices which are offline.</li>\n\t<li>Fixed an issue where error messages were printed for ignorable errors.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi:70.4150.0.119-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Microchip-smartpqi:70.4150.0.119-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。errataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"77793","datemodified":"2022-01-25T13:40:16","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/smartpqi","./lib/modules/4.18.0-305.el8.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"e99212431741b41adac7280695fdccb8","name":"kmod-smartpqi-2.1.16-030.rhel8u4.x86_64.rpm","release":"2022-01-25T13:29:10","revision":"0","sha1sum":"6da49a071846ec9ab6d40f1e7209a60aeaf99782","size":"75KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.16-030"},{"bytes":"77797","datemodified":"2022-01-25T13:38:57","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.18.0-348.el8.x86_64","./lib/modules/4.18.0-348.el8.x86_64/extra","./lib/modules/4.18.0-348.el8.x86_64/extra/smartpqi","./lib/modules/4.18.0-348.el8.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"4b3d74457207312bee87707246e06685","name":"kmod-smartpqi-2.1.16-030.rhel8u5.x86_64.rpm","release":"2022-01-25T13:29:10","revision":"0","sha1sum":"5a15e81c699bbc37f28c351c7602679c2f6870b0","size":"75KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.16-030"}],"id":{"product":"d952c2a30d6f4bb29ccf7ec141400337","version":"5b57e90ecf2e4097b936419237f48d21"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-&lt;version&gt;.rhel8&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel8&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array&nbsp;controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 8 (64-bit)"},{"lang":"ja","x_late":"HPE ProLiant Gen10 および Gen10Plus Smartアレイコントローラー(64ビット)ドライバー for Red Hat Enterprise Linux 8 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T15:50:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Adding RHEL8.5 support</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Blade Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVMバージョン</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート 560FLBアダプター</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2ポート560Mアダプター</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2836.0は以下を含みます：ブートエージェント：1GbE - v1.5.88、10GbE - v2.4.44、40GbE - v1.1.18 &UEFIドライバー：1GbE - v9.4.06、10GbE - v7.8.13、40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"8243623","datemodified":"2021-03-09T17:58:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/CP045078.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560FLB_G33590-000_2.45_800008F0.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_560M_G43498-00X_2.18_8000083D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/ofvpdfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/nic_fw/rfendfix64e","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-bl-1.2.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045078.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045078.scexe"],"md5sum":"55753286ff1cc2ba87f8059fd4015d6e","name":"firmware-nic-intel-bl-1.2.3-1.1.x86_64.rpm","release":"2021-03-31T00:00:00","revision":"1","sha1sum":"f298bc0185b14c3c82cdf60cd9c09d77c8068de5","size":"7MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3"}],"id":{"product":"efc60b9bf1a141328e5b2c582be6ef7b","version":"25702105733f4cbc858bd4c6e43ab3ca"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p>\n\n<ul>\n\t<li>ファームウェアrpmパッケージをインストールします。<br />\n\t<em>> rpm -ivh <rpm_filename>.rpm </em></li>\n\t<li>ファイルを抽出する場所を確認します。<br />\n\t<em>> rpm -qlp <rpm_filename>.rpm</em></li>\n\t<li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li>\n</ul>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-30T17:45:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWCBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757434243","Version":"HPG6"},{"DeviceName":"MB002000GWCBD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WRN620G6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757434244","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB001000GWCBC and MB002000GWCBD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)-&nbsp;&nbsp;MB001000GWCBC and MB002000GWCBD Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5891226","datemodified":"2021-07-23T08:03:26","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/CP048093.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/WRN620G6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-68b12e54d2-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048093.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048093.scexe"],"md5sum":"464ef5a99d8c590b159bcf06dd22709f","name":"firmware-hdd-68b12e54d2-HPG6-6.1.x86_64.rpm","release":"2021-07-23T07:49:09","revision":"0","sha1sum":"8da7ebad42f49d3ac26b2ecd3f77c52c988db828","size":"5MB","target_guids":["4d2340a5-3042-3130-3030-304757434243","4d2340a5-3042-3230-3030-304757434244"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"c41c6d23d08b454ca2ee1c24f966683f","version":"ae965177a92e4f78ae75c731dae78408"},"installation":{"command":"CP040777.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWCBC and MB002000GWCBD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWCBCおよびMB002000GWCBDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB001000GWCBC","target_guid":"4d2340a5-3042-3130-3030-304757434243","type":"sata"},{"id":"MB002000GWCBD","target_guid":"4d2340a5-3042-3230-3030-304757434244","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:10:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWCBC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWCBD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17656997","datemodified":"2022-02-21T05:13:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/A40_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/CP050796.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050796.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050796.scexe"],"md5sum":"db76f40ce6b39e74a72d187bb88c98b5","name":"firmware-system-a40-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T05:06:58","revision":"0","sha1sum":"a56d7f39112c7dda688d28cb7bb306eb29660a38","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"d313ecbde1f54151bf42ad357e6b94ad","version":"368c464fcbe440ee90b4db4536efb54f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL385 Gen10 (A40) サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T04:08:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFEML and MB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3625856","datemodified":"2021-07-25T14:20:05","file_list":["cp048590.xml","cpqsetup.exe","HAKPNSD6.rel","payload.json","setup.dll"],"md5sum":"6a646078709a2e476cf4e04b67ae0e15","name":"cp048590.exe","release":"2021-07-25T14:13:05","revision":"0","sha1sum":"0500c2eba0c4df5011191314f60af3ec473058e0","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"43e2b01e979548ad962efb95de5a6d12","version":"eac7f4dc955b411682f2eae4b268c1da"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:57:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"426057","datemodified":"2021-08-27T06:20:39","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/brcmfcoe.ko","./usr/share/smartupdate/brcmfcoe-kmp-default/component.xml"],"md5sum":"f62c630651914342473dd75bd27e417a","name":"brcmfcoe-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-27T06:11:03","revision":"0","sha1sum":"e6ecc7ed190992d3affa3b281e43cec1ace10b2b","size":"416KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08941732"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"497dff17dd524ba3a936f4d2ccd99da8","version":"65064765dcce441a87e8638790258a28"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.sles12sp5.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 service pack 5 Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:12:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for SLES 12 SP5</li>\n</ul>\n\n<p>Updated to Driver version 12.0.1342.0</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where cluster nodes could be evicted during Fibre Channel over Ethernet (FCoE) multipath failover as described in <a href=\"https://access.redhat.com/solutions/3136041\">https://access.redhat.com/solutions/3136041</a></li>\n\t<li>Fixed a behavior where Ethernet connections may not recover after a Virtual Connect (VC) interconnect module reboot</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"brcmfcoe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB6000GEQUT and MB8000GEQUU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MB6000GEQUTおよびMB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Fixed the issue of Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5584068","datemodified":"2021-07-23T07:34:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/CP048167.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/HAHc8HaoeFGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1d7f19120b-HPGB-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048167.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048167.scexe"],"md5sum":"f73d8fabe5ddafcaf46fc56dc84e925d","name":"firmware-hdd-1d7f19120b-HPGB-9.1.x86_64.rpm","release":"2021-07-23T07:22:11","revision":"0","sha1sum":"f9221262d64842a5a6aa3f8615696412291f2166","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"f588f22bf7a8476e978b8ff370066200","version":"dc048560551b44d082dd64fa780e9834"},"installation":{"command":"CP040322.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:38:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17238411","datemodified":"2021-08-26T20:48:52","file_list":["/CP048377_BUILD_2.data","/CP048377.vmexe","/CP048377.vmexe64","/CP048377.vmfile","/CP048377_VMw.zip","/CP048377.xml","/payload.json","/CP048377_VMw.zip/index.xml","/CP048377_VMw.zip/vendor-index.xml","/CP048377_VMw.zip/metadata.zip","/CP048377_VMw.zip/vib20/CP048377/HPE_bootbank_CP048377_HPG4.2-7.0.0.15843807.vib","/CP048377_VMw.zip/metadata.zip/vendor-index.xml","/CP048377_VMw.zip/metadata.zip/vmware.xml","/CP048377_VMw.zip/metadata.zip/vibs/CP048377-8393986470591433366.xml","/CP048377_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048377_HPG4.2-7.0.0.15843807.xml"],"md5sum":"ef46350f89f570bb238369269712d179","name":"CP048377.zip","release":"2021-08-26T20:43:40","revision":"0","sha1sum":"463fe32444412e8f48ac63358e796fb2773915ed","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048377","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"474dacedc05a47e69c05eb6235e4913d","version":"47b7546d1533489ca98cd9f2bd79f80b"},"installation":{"command":"CP040687.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T07:19:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653436A-HDAI OCP3 PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 MCX653436A-HDAI OCP3 PCIe4 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter (P31348-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>MT_0000000593</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5952934","datemodified":"2021-12-07T10:24:57","file_list":["20_32_1010-MCX653436A-HDA_HPE_Ax.pldm.signed","20_32_1010-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"df7ddc346da381646ea0090aa24e007a","name":"20_32_1010-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T10:21:50","revision":"0","sha1sum":"edbeee45f25c5fbc50c1747a5f6cdabd85ee9419","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900348"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"3f4d9eceae63421389745abdf06f001a","version":"46d03e76315749d6b0e937e4d972265b"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653436A-HDAI OCP3 PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 MCX653436A-HDAI OCP3 PCIe4 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"100964","datemodified":"2021-03-08T18:02:04","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"7d01d1f1d7997fdf297c2e45190cb822","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"01cac2c76a503b9065e5455abd6888535fab2e6a","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"100969","datemodified":"2021-03-08T17:59:24","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net_bl/component.xml"],"md5sum":"d006b6949e0a390a0252a4f6b56629d2","name":"kmod-be2net_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:14","revision":"0","sha1sum":"105f32e3b2493ef3a74fc1642d2fee9f46a557fc","size":"98KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec04f7105f"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"2d95bd349a5f487bbf7bbf3c783e4857","version":"2518ca8f7bf64c0180e2fcefe647aa86"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8 and Red Hat Enterprise Linux 7 Update 9.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1612184","datemodified":"2021-08-26T09:43:03","file_list":["cp047201.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"2120ff206f0cd99febbda2f19498ff1e","name":"cp047201.exe","release":"2021-08-26T09:40:10","revision":"0","sha1sum":"9331e2b45558fc5941579cffc6a81e31ea55752b","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"07117e80b64248dab9811a2280fcc85e","version":"3fb5c71f544442f69ab5b561f72a0088"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-17T09:15:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>\n\t<p dir=\"LTR\">Initial driver for Windows 2022</p>\n\t</li>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPD9"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTED9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000600JWCPF and EH000900JWCPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000600JWCPFおよびEH000900JWCPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;EH000600JWCPF and EH000900JWCPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17939226","datemodified":"2021-08-30T06:15:16","file_list":["/CP048272_BUILD_2.data","/CP048272.vmexe","/CP048272.vmexe64","/CP048272.vmfile","/CP048272_VMw.zip","/CP048272.xml","/payload.json","/CP048272_VMw.zip/index.xml","/CP048272_VMw.zip/vendor-index.xml","/CP048272_VMw.zip/metadata.zip","/CP048272_VMw.zip/vib20/CP048272/HPE_bootbank_CP048272_HPD9.2-7.0.0.15843807.vib","/CP048272_VMw.zip/metadata.zip/vendor-index.xml","/CP048272_VMw.zip/metadata.zip/vmware.xml","/CP048272_VMw.zip/metadata.zip/vibs/CP048272-698966563930879478.xml","/CP048272_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048272_HPD9.2-7.0.0.15843807.xml"],"md5sum":"453a38a06578230a6abe3a8f6a741ec9","name":"CP048272.zip","release":"2021-08-30T06:09:00","revision":"0","sha1sum":"2dd336c5fb32430581638538edb5c460313bf62e","size":"17MB","target_guids":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048272","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"ec5fd859b967489ab6f67ad677712984","version":"01e1af1d79f742f8b211eaccc0316d90"},"installation":{"command":"CP040536.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000600JWCPFおよびEH000900JWCPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000600JWCPF","target_guid":"452340a5-3048-3030-3630-304a57435046","type":"sas"},{"id":"EH000900JWCPH","target_guid":"452340a5-3048-3030-3930-304a57435048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T17:46:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWCPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication."},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13684246","datemodified":"2022-02-03T12:52:00","file_list":["/cp050293.xml","/HPE-Utility-Component_10.9.0.670-5.zip","/HPE-Utility-Component_10.9.0.670-5.zip/index.xml","/HPE-Utility-Component_10.9.0.670-5.zip/vendor-index.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip","/HPE-Utility-Component_10.9.0.670-5.zip/ilo_670.10.7.5.2-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/hponcfg-6.7.0.5.5-0.18.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/MIS_bootbank_hpessacli_5.30.6.0-6.7.0.7535516.oem.vib","/HPE-Utility-Component_10.9.0.670-5.zip/conrep_670.10.8.0.18-6.7.0.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/testevent-6.7.0.02-01.00.12.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/bootcfg-6.7.0.02-06.00.14.7535516.vib","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vendor-index.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vmware.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/ilo-2964936189223017316.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/hponcfg--6504653738878051635.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/cru--1581854872647123919.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/hpessacli--7301454814453753484.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/conrep--7426494458955974697.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/testevent--7260039959213699592.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/vibs/bootcfg-3356455625267296249.xml","/HPE-Utility-Component_10.9.0.670-5.zip/metadata-HPE-Utility-Component_10.9.0.670-5.zip/bulletins/esxi6.7-util-bundle-10.9.0.670-5.xml"],"md5sum":"3acf695c787465964e9265412cd568ce","name":"cp050293.zip","release":"2022-02-03T12:51:43","revision":"0","sha1sum":"e03075c8727fc5bc3a43c6e9f90d3103166a6e73","size":"13MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"ilo","version":"670.10.7.5.2-1OEM.670.0.0.7535516"},{"name":"hponcfg","version":"6.7.0.5.5-0.18.7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"},{"name":"hpessacli","version":"5.30.6.0-6.7.0.7535516.oem"},{"name":"conrep","version":"670.10.8.0.18-6.7.0.7535516"},{"name":"testevent","version":"6.7.0.02-01.00.12.7535516"},{"name":"bootcfg","version":"6.7.0.02-06.00.14.7535516"}]}],"id":{"product":"53bb40aec8a14ed088d9afe01e9aba86","version":"d88877d37e73439098b5b79f0e4f6141"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.7 "},{"lang":"ja","x_late":"HPE ユーティリティバンドル Smartコンポーネント for ESXi 6.7 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-23T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>hpeeacli - The Smart Storage Administrator CLI is a commandline-based disk configuration program for Smart Array Controllers and SmartRAID Controllers.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"ilo:670.10.7.5.2-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.7.0.02-06.00.14.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli:5.30.6.0-6.7.0.7535516.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:670.10.8.0.18-6.7.0.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"hponcfg:6.7.0.5.5-0.18.7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"testevent:6.7.0.02-01.00.12.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A40_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17930208","datemodified":"2022-02-21T05:08:14","file_list":["A40_2.56_02_10_2022.signed.flash","cp050794.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"c91af930518041a09125c8b274bfa3d5","name":"cp050794.exe","release":"2022-02-21T05:06:28","revision":"0","sha1sum":"23ed644ad3f03b6579e99985e4bac0657f4932ca","size":"17MB","target_guids":["00000000-0000-0000-0000-00000000020a"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"f8437d6127664644832d2cd688d58903","version":"7f890edf9c144ccd90162b3d4a412122"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL385 Gen10 (A40) サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T04:08:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"}],"sw_keys":[{"name":"A40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for Linux (x64) - &nbsp;MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p>&nbsp;<strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"7064464","datemodified":"2021-09-21T08:06:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/CP048229.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/KPE60X1GHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048229.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048229.scexe"],"md5sum":"65c7d017954ac9493f98725b0269aef6","name":"firmware-hdd-54addf5312-HPK3-6.1.x86_64.rpm","release":"2021-09-21T07:51:10","revision":"0","sha1sum":"715705882789b83e49557e8bac244abf53d7fb49","size":"6MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"3d004333c656491289fdf09d5881fcdd","version":"0cc49d0183f943c7b2a9f8ec056ad56c"},"installation":{"command":"CP041698.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux（x64）- MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、VK000960KWWFL、VK001920KWWFN、VK003840KWWFP、およびVK007680KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:48:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator (SSA) is a web-based application that helps you configure, manage, diagnose, and monitor Smart Array and SmartRAID Controllers and now other storage devices as well, such as host bus adapters (HBAs), Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of SSA, with the appropriate firmware."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>Please make sure the following browser options are enabled:</p>\n\n<ul>\n\t<li>Automatically load images and other data types.</li>\n\t<br />\n\t<li>JAVA script</li>\n\t<br />\n\t<li>Style sheets</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"11788615","datemodified":"2022-01-24T11:22:43","file_list":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"md5sum":"8d8164b63d9c89f393e8e382e0102033","name":"ssa-5.30-6.0.x86_64.rpm","release":"2022-01-24T11:21:54","revision":"0","sha1sum":"5c0bdcce07b81db4b619a89fa26cf666cf23b078","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"39676e9bd8d74e11b8837e3f6ebabd5c","version":"8f2cfabf0d3245c5ab2ca73c20701488"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSA is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSA installed on the system, please use &quot;rpm -e ssa&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/smartstorageadmin/ssa and the executable name is ssa which is located in /usr/sbin.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Smart Storage Administrator (SSA) for Linux 64-bit"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator (SSA)"},{"lang":"ja","x_late":"Smart Storage Administrator (SSA) for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:01:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssa","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO0800JEFPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3830-304a45465046","Version":"HPD3"},{"DeviceName":"EO0400JEFPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3430-304a45465045","Version":"HPD3"},{"DeviceName":"EO0200JEFPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304f-3230-304a45465044","Version":"HPD3"},{"DeviceName":"MO1600JEFPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a45465043","Version":"HPD3"},{"DeviceName":"MO0800JEFPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a45465042","Version":"HPD3"},{"DeviceName":"MO0400JEFPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a45465041","Version":"HPD3"},{"DeviceName":"MO0200JEFNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HSSCPCD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3230-304a45464e56","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for&nbsp;VMware ESXi&nbsp;- MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE&nbsp;and EO0800JEFPF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16874323","datemodified":"2021-08-27T07:33:26","file_list":["/CP048401_BUILD_3.data","/CP048401.vmexe","/CP048401.vmexe64","/CP048401.vmfile","/CP048401_VMw.zip","/CP048401.xml","/payload.json","/CP048401_VMw.zip/index.xml","/CP048401_VMw.zip/vendor-index.xml","/CP048401_VMw.zip/metadata.zip","/CP048401_VMw.zip/vib20/CP048401/HPE_bootbank_CP048401_HPD3.3-7.0.0.15843807.vib","/CP048401_VMw.zip/metadata.zip/vendor-index.xml","/CP048401_VMw.zip/metadata.zip/vmware.xml","/CP048401_VMw.zip/metadata.zip/vibs/CP048401--5580745014109652053.xml","/CP048401_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048401_HPD3.3-7.0.0.15843807.xml"],"md5sum":"dd3ffed120370b5e791aa09d4fe2b36c","name":"CP048401.zip","release":"2021-08-27T07:28:00","revision":"0","sha1sum":"3a73dd1235bfe5ef218e3fc213e6754d6053c8b4","size":"16MB","target_guids":["002340a5-4500-304f-3830-304a45465046","002340a5-4500-304f-3430-304a45465045","002340a5-4500-304f-3230-304a45465044","002340a5-4d00-314f-3630-304a45465043","002340a5-4d00-304f-3830-304a45465042","002340a5-4d00-304f-3430-304a45465041","002340a5-4d00-304f-3230-304a45464e56"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048401","version":"HPD3.3-7.0.0.15843807"}]}],"id":{"product":"22bf9e4ced19410ca8b8850245112a89","version":"17921eb24c6f42faa96f6d5e01004f4c"},"installation":{"command":"CP039420.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0200JEFNV, MO0400JEFPA, MO0800JEFPB, MO1600JEFPC, EO0200JEFPD, EO0400JEFPE and EO0800JEFPF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - MO0200JEFNV、MO0400JEFPA、MO0800JEFPB、MO1600JEFPC、EO0200JEFPD、EO0400JEFPE、およびEO0800JEFPFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EO0800JEFPF","target_guid":"002340a5-4500-304f-3830-304a45465046","type":"sas"},{"id":"MO1600JEFPC","target_guid":"002340a5-4d00-314f-3630-304a45465043","type":"sas"},{"id":"EO0200JEFPD","target_guid":"002340a5-4500-304f-3230-304a45465044","type":"sas"},{"id":"MO0200JEFNV","target_guid":"002340a5-4d00-304f-3230-304a45464e56","type":"sas"},{"id":"EO0400JEFPE","target_guid":"002340a5-4500-304f-3430-304a45465045","type":"sas"},{"id":"MO0400JEFPA","target_guid":"002340a5-4d00-304f-3430-304a45465041","type":"sas"},{"id":"MO0800JEFPB","target_guid":"002340a5-4d00-304f-3830-304a45465042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T19:08:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO0200JEFPD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0400JEFPE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO0800JEFPF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0200JEFNV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JEFPC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0800JEFPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JEFPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5505396","datemodified":"2021-07-23T09:22:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/CP048203.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/SCIMARRNNTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048203.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048203.scexe"],"md5sum":"592e3e6c9a31d1c868f6310290911eaa","name":"firmware-hdd-12304c1aca-HPG3-3.1.x86_64.rpm","release":"2021-07-23T09:09:10","revision":"0","sha1sum":"f9affa138ccbed9e8b24f83e5b2ab07578a08f26","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"205e86b4ae1e4a28ae1e3cf39faf17ba","version":"26220bd464044731946a4aa2a8156cfc"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:23:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Mezzanine Host Bus Adapter driver support for HPE Blade Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2039576","datemodified":"2021-08-27T05:41:03","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp046758.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"821a42f50b01b709b67da7e581bd3e23","name":"cp046758.exe","release":"2021-08-27T05:37:12","revision":"0","sha1sum":"2d1a64a149153da0bda7cab18a89bd171b954b87","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"44342a3601e1466c9e7b89e65ba92f03","version":"5359859516ed43a289c59ce5cc399c67"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Storage Mezzanine Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_3p00_PLDMoMCTP_80008250.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-XXVDA2 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter</td>\n\t\t\t<td>80008250</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t\t<th>NVMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター</td>\n\t\t\t<td>80008250</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2992.0は以下を含みます：インテル(R)ブートエージェントICE v2.5.0およびUEFI x64 100ギガビットドライバーv3.0.11。</p>\n"}],"files":[{"bytes":"10518217","datemodified":"2021-08-12T14:21:03","file_list":["HPE_E810_XXVDA2_SD_3p00_PLDMoMCTP_80008250.HPb","HPE_E810_XXVDA2_SD_3p00_PLDMoMCTP_80008250.xml","payload.json"],"md5sum":"c457c6bbda5b26eb3223acbf29543b10","name":"HPE_E810_XXVDA2_SD_3p00_PLDMoMCTP_80008250.fwpkg","release":"2021-09-16T00:00:00","revision":"1","sha1sum":"c24d90944dee83fde2940a214a6837c9851d7b69","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159b80860003"],"type_of_change":"1","version":"3.00"}],"id":{"product":"0134d053d49b43b1add04e5a51f6ff18","version":"614beebbe0ab46419cf6d86c9ae77739"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T08:47:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_XXV2_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB016000GWXKK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5533479","datemodified":"2021-07-26T16:40:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/CP049129.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/TAMG08acHPG3.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049129.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049129.scexe"],"md5sum":"ed7517c851a6c4a5eda69c291168d1fb","name":"firmware-hdd-e4f147cdd2-HPG3-2.1.x86_64.rpm","release":"2021-07-26T16:27:04","revision":"0","sha1sum":"86b88f4155204df9c53d583c8514143c770bc75b","size":"5MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"d780ef43938c40d3a6628583fe2200f7","version":"594d2b7521c8423cbc6dbf27c29d0773"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:22:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 2."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25192","datemodified":"2021-02-11T01:05:26","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/99","./usr/lib/.build-id/99/2d3ab5d9085915f48edcbc531702436c72fb53","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"22b00b36be7f99a9a827c2f382c7acfc","name":"libbnxt_re-218.0.7.0-rhel8u2.x86_64.rpm","release":"2021-02-11T01:02:04","revision":"0","sha1sum":"be366120973b74019a8d48f7255610407840bb13","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"67c1e7cc9a5f4a98b6e37ff05556aec1","version":"228b5255801449f6a047211f91a3c05e"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 2."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1755705","datemodified":"2021-12-14T03:07:50","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/compat","./lib/modules/5.3.18-22-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-22-default/updates/drivers","./lib/modules/5.3.18-22-default/updates/drivers/base","./lib/modules/5.3.18-22-default/updates/drivers/base/auxiliary.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-22-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-22-default/updates/drivers/net","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-22-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host","./lib/modules/5.3.18-22-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target","./lib/modules/5.3.18-22-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-22-default/updates/net","./lib/modules/5.3.18-22-default/updates/net/9p","./lib/modules/5.3.18-22-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/mlxdevm","./lib/modules/5.3.18-22-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/5.3.18-22-default/updates/net/rds","./lib/modules/5.3.18-22-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-22-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"8716825b70dcf6be68ef5b3f2cd70fe8","name":"mlnx-ofa_kernel-kmp-default-5.5_k5.3.18_22-OFED.5.5.1.0.3.1.sles15sp2.x86_64.rpm","release":"2021-12-14T01:57:15","revision":"0","sha1sum":"d0e2401b77ccc858a35e1cca51135364b79e14ac","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"},{"bytes":"1425380","datemodified":"2021-12-14T03:04:50","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.4.0","./usr/share/doc/packages/libvma-9.4.0/CHANGES","./usr/share/doc/packages/libvma-9.4.0/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"96b2bae427048629ef693c5204227431","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.sles15sp2.x86_64.rpm","release":"2021-12-14T01:57:15","revision":"0","sha1sum":"214ad1b7fadca3ab5fd456735cb06fc1a1f2555a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"}],"id":{"product":"725f060c9eaa4196aa47bcf7495820ec","version":"6b118ea3a3e2425091a931f0d06bf7c4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 5.3.18-22-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.sles15sp2.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.5_k5.3.18_22-OFED.5.5.0.4.4.1.sles15sp2.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP2 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"4355656","datemodified":"2021-07-23T05:55:11","file_list":["cp048563.xml","cpqsetup.exe","HLEBHssseFD3.rel","payload.json","setup.dll"],"md5sum":"0edd8a8162823b9c34afcacf924f9a65","name":"cp048563.exe","release":"2021-07-23T05:47:07","revision":"0","sha1sum":"cbe97453577cac106b87c610f5ac6bc1f9f8c6a0","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"83ce77cbc6db45d29c95de38716f222e","version":"b872dedf403047a9ad1ef20e55455eb2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWUDB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:00:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux platforms."},{"lang":"ja","x_late":"このパッケージには、Linux プラットフォームで動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3155085","datemodified":"2021-08-16T16:47:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/CP047648.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/CP047648.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/nic_fw/hp_mbi_7.18.82.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-bl-1.5.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP047648.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP047648.scexe"],"md5sum":"3af62345886d878cf4f9958ec039e49a","name":"firmware-nic-qlogic-nx2-bl-1.5.2-1.1.x86_64.rpm","release":"2021-08-16T16:39:03","revision":"0","sha1sum":"714072e00138f5bb60b904dd96fab3ad65910577","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.5.2"}],"id":{"product":"0b1755ac9ea74055988f525407cd9d18","version":"375091eba3814c0199caeceb07a68f44"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Linux"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティfor Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.<br />\nThis product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.<br />\nThis product now supports SUSE Linux Enterprise Server 12 SP5.<br />\nThis product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 Update 4.<br />\nThis product now supports SuSE Linux Enterprise Server 15 SP3.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for NS204i-p/d/r/t","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_PLDM_1060.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.0.14.1060"},{"DeviceName":"PMCI PLDM FW Update for NS204i-p/d/r/t","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_PLDM_1060.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.0.14.1060"},{"DeviceName":"PMCI PLDM FW Update for NS204i-p/d/r/t","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_PLDM_1060.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.0.14.1060"},{"DeviceName":"PMCI PLDM FW Update for NS204i-p/d/r/t","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_NS204i_Gen10P_PLDM_1060.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.0.14.1060"}]},"MinimumActiveVersion":"1.0.14.1055","PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE Boot Controller NS204i-p."},{"lang":"ja","x_late":"HPEブートコントローラーNS204i-p用ユニバーサルファームウェアPLDMファイル。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7366099","datemodified":"2021-09-06T14:33:07","file_list":["HPE_NS204i_Gen10P_PLDM_1060.ilo","HPE_NS204i_Gen10P_PLDM_1060.xml","payload.json"],"md5sum":"04d2e761f99984a62c388adeb19f518f","name":"HPE_NS204i_Gen10P_PLDM_1060.fwpkg","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"cbfae69350276efbb18486cf40a827ebbf6e583f","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6"],"type_of_change":"1","version":"1.0.14.1060"}],"id":{"product":"bce7ca8e9bb8402aa17bed3ad9def21a","version":"85f89fc60ae94ff0a96ec9dc73f947af"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Universal Firmware Package for HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r "},{"lang":"ja","x_late":"HPE Gen10 PlusブートコントローラーNS204i-p、NS204i-d、NS204i-t、NS204i-r用のユニバーサルファームウェアパッケージ "}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030e","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"030F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-22411590030f","type":"pci","ven":"1B4B"},{"dev":"2241","subdev":"0310","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-224115900310","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-12T02:35:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Enable PLDM T5 FWPKG for controller FW flashing directly through iLO</p>\n\t</li>\n\t<li>\n\t<p>IML event enhancement</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Enable PLDM T5 FWPKG for controller FW flashing directly through iLO</p>\n\t</li>\n\t<li>\n\t<p>IML event enhancement</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"03101590","sw_key_expectedpath":"firmware"},{"name":"030e1590","sw_key_expectedpath":"firmware"},{"name":"030f1590","sw_key_expectedpath":"firmware"},{"name":"02F61590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33809039","datemodified":"2022-02-21T12:54:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/A48_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/CP050508.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050508.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050508.scexe"],"md5sum":"f6b2c13f4d81575c56248264e2d467ff","name":"firmware-system-a48-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T12:48:08","revision":"0","sha1sum":"c9f6477b5b8dfcd3be76b6f33470b1fb7e2d9c4a","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"1e4f77062f4d48c8906f4212d8016a76","version":"a6f6f0f62a684e2c975635cec20218c0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:44:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.19.31"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, and CCM code running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v20.19.31 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>NCSI Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>BCM 5720 1GbE 2p BASE-T LOM Adptr</td>\n\t\t\t<td>1.42</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.30</td>\n\t\t\t<td>21.6.28</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージには、以下のファームウェアバージョンを含むコンボイメージv20.19.31が含まれています：</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>ブートコードバージョン</strong></td>\n\t\t\t<td><strong>PXEバージョン</strong></td>\n\t\t\t<td><strong>NCSIバージョン</strong></td>\n\t\t\t<td><strong>UEFIバージョン</strong></td>\n\t\t\t<td><strong>CCMバージョン</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>BCM 5720 1GbE 2p BASE-T LOMアダプター</td>\n\t\t\t<td>1.42</td>\n\t\t\t<td>21.6.0</td>\n\t\t\t<td>1.5.30</td>\n\t\t\t<td>21.6.28</td>\n\t\t\t<td>218.0.10.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"1556314","datemodified":"2021-08-26T11:32:46","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/CP048907.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/CP048907.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/nic_fw/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.28.3-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048907.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048907.scexe"],"md5sum":"ed3e900f43f3e7950a408bef33d408c4","name":"firmware-nic-bcm-open-2.28.3-1.1.x86_64.rpm","release":"2021-09-17T00:00:00","revision":"1","sha1sum":"196670bcb4ba0838e59df9e510ae78982daa5ab2","size":"1MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F14E4159C"],"type_of_change":"1","version":"2.28.3"}],"id":{"product":"110c3bd2bca349b2ba7b9fec9e58ee8d","version":"e76fa2df76824ccf9b59f1ea2299a77c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CP048907.txt file.The results of the firmware upgrade are saved&nbsp;in CP048907.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong>rpmパッケージを使用してアダプターファームウェアをアップデートする手順：</strong></em></p>\n\n<ul>\n\t<li>ファームウェアrpmパッケージをインストールします。<br />\n\t<em>> rpm -ivh <rpm_filename>.rpm </em></li>\n\t<li>ファイルを抽出する場所を確認します。<br />\n\t<em>> rpm -qlp <rpm_filename>.rpm</em></li>\n\t<li>前のステップからの出力を使用してhpsetupファイルの場所を判別し、そのディレクトリに変更して'<em>./hpsetup</em>'を実行してファームウェアをアップデートします。</li>\n</ul>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>詳細情報はCP048907.txtファイルにあります。ファームウェアのアップグレードの結果は\"/var/cpq/\"のCP048907.logに保存されます。</li>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアのrpmパッケージ（rpm -ivh）をインストールしてもアダプターファームウェアはアップデートされず、rpmパッケージの内容がローカルシステムに抽出されるだけです。アダプターファームウェアをアップデートするには、上記の手順に従う必要があります。</li>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ja","x_late":"Broadcom NX1オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-23T02:06:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"BCM_OPEN","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.00"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-b SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0701","Version":"5.00"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.00"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.00"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.00"},{"DeviceName":"HPE Smart Array P408i-sb Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0609","Version":"5.00"},{"DeviceName":"HPE Smart Array P408e-m SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HPE_luxor.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0655","Version":"5.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following storage controllers: HPE Smart Array P408i-p, P408e-p, P408i-a, P408e-m, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP408i-p、P408e-p、P408i-a、P408e-m、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi - HPE&nbsp;Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; 4.69</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; 4.11<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added UBM type3 backplane support</li>\n\t<li>Added support for long device model/product ID for SATA drives.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp; &nbsp; &nbsp;</p>\n\n<p>&nbsp; &nbsp; &nbsp;</p>\n\n<ul>\n\t<li style=\"list-style-type:disc\">An issue where the controller might become unresponsive while receiving periodic I/Os.</li>\n\t<li style=\"list-style-type:disc\">Host I/O timeouts might occur due to continuing firmware attempts to discover devices during an expander configuration.</li>\n\t<li style=\"list-style-type:disc\">A controller lockup problem (with code 0x1E10) might occur when a bad drive with unsupported block size.</li>\n\t<li style=\"list-style-type:disc\">A Controller hangs when multiple hot-plug and hot remove events (drives or JBODs) were being processed.</li>\n\t<li style=\"list-style-type:disc\">A Controller hangs on Flash Backed Write Cache enabled logical drives with sequential read towards the end of the logical drive.</li>\n\t<li style=\"list-style-type:disc\">A Controller hangs when hot-plug physical drive with outstanding I/Os.</li>\n\t<li style=\"list-style-type:disc\">A controller hangs if a host I/O and background consistency check simultaneously encounter a RAID-1 ADM or RAID-10 ADM stripe in which all drives have URE&#39;s on the same LBA.</li>\n\t<li style=\"list-style-type:disc\">A Controller hangs when a drive is failed from a RAID6/60 logical drive when the host issues a Clear Controller Configuration command or any other configuration change command.</li>\n\t<li style=\"list-style-type:disc\">The SSD data drive might be set offline (with reason code 0x37) when hot-remove and re-insert during a spare rebuild in progress.</li>\n\t<li style=\"list-style-type:disc\">A drive might not be exposed to the OS if the system is rebooted just after the sanitize erase finishes.</li>\n\t<li style=\"list-style-type:disc\">UBM backplanes are not detected properly when connected to specific ports (port 7 or above) in the 12Gb SAS Expander Card.</li>\n\t<li style=\"list-style-type:disc\">A controller might hang when idle followed by a short burst of I/Os.</li>\n\t<li style=\"list-style-type:disc\">The controller might return the previous drive firmware version, after a drive firmware update on SATA drives.</li>\n\t<li style=\"list-style-type:disc\">The controller might fail drives (with reason code 0x49, I/O freeze timeout) during expander firmware upgrade on a multi-expander enclosure configuration.</li>\n\t<li style=\"list-style-type:disc\">Hot-added drive LED control fails on specific fan-out expander type external enclosure models.</li>\n\t<li style=\"list-style-type:disc\">Smart Array Essential series controller might not be responsive when processing sequential I/Os and the firmware coalescing logic can&#39;t get the memory.</li>\n\t<li style=\"list-style-type:disc\">Filesystem or application might read old data when SmartCache configurations encounter intermittent write I/O errors to a primary logical drive.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22998421","datemodified":"2022-01-23T16:53:52","file_list":["/CP049390_BUILD_8.data","/CP049390.vmexe","/CP049390.vmexe64","/CP049390.vmfile","/CP049390_VMw.zip","/CP049390.xml","/payload.json","/CP049390_VMw.zip/index.xml","/CP049390_VMw.zip/vendor-index.xml","/CP049390_VMw.zip/metadata.zip","/CP049390_VMw.zip/vib20/CP049390/HPE_bootbank_CP049390_5.00.8-7.0.0.15843807.vib","/CP049390_VMw.zip/metadata.zip/vendor-index.xml","/CP049390_VMw.zip/metadata.zip/vmware.xml","/CP049390_VMw.zip/metadata.zip/vibs/CP049390-2034117286565407910.xml","/CP049390_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049390_5.00.8-7.0.0.15843807.xml"],"md5sum":"f793fdae4cb1c7757a0f7f59fddb4bc3","name":"CP049390.zip","release":"2022-01-23T16:41:59","revision":"0","sha1sum":"0e20c6f75b3ce6026bf44113776d54345f02117e","size":"21MB","target_guids":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0609","a6b1a447-382a-5a4f-9005-028f103c0655"],"type_of_change":"1","version":"5.00","vib_list":[{"name":"CP049390","version":"5.00.8-7.0.0.15843807"}]}],"id":{"product":"4f319faf890642fc80a3d8719760c121","version":"6eaf458ce833449080b0edc140e38c2c"},"installation":{"command":"CP049390.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.1.2-126","description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4-101","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673","description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847","description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599","description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408i-sb, P408e-m, P204i-c, P204i-b, P816i-a and P416ie-m SR Gen10"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE SmartアレイP408i-p、P408e-p、P408i-a、P408i-c、E208i-p、E208e-p、E208i-c、E208i-a、P408i-sb、P408e-m、P204i-c、P204i-b、P816i-a、およびP416ie-m SR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T16:13:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where SSD SmartPath is not enabled on logical drives created on the same array in certain scenarios.</li>\n\t<li>Fixed a problem where WRITE and READ fails with URE on a RAID6 volume where it could have completed successfully in certain error recovery scenarios.</li>\n\t<li>Fixed a problem where events were not getting logged in certain scenarios.</li>\n\t<li>Fixed an issue where a Windows memory dump process was taking longer than 30 minutes.</li>\n\t<li>Fixed a problem in Gen10&nbsp;server where FAULT LED was not turning on for the drives failing during device discovery.</li>\n\t<li>Fixed a problem where the critical event &quot;Controller memory ECC error limit exceeded&quot; was reported in the AHS IML log after upgrading to 3.53 B0 firmware build.</li>\n\t<li>Fixed a problem where the host WRITE I/O failed on the SmartCache logical drive with UREs present on the primary logical drive.</li>\n\t<li>Fixed an issue where the controller may be non-responsive after drive failure with SSD SmartPath enabled under a high queue depth workload.</li>\n\t<li>Fixed a performance issue when the host is submitting large sequential IO streams at high queue depth.</li>\n\t<li>Fixed an issue where OS filesystem is not available after making configuration changes in HII.</li>\n\t<li>Fixed an issue where error was observed while selecting edit SmartCache Logical drive option when SmartCache logical drive is in Degraded mode.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"0655103C","sw_key_expectedpath":"firmware"},{"name":"0609103C","sw_key_expectedpath":"firmware"},{"name":"0700103C","sw_key_expectedpath":"firmware"},{"name":"0654103C","sw_key_expectedpath":"firmware"},{"name":"0602103C","sw_key_expectedpath":"firmware"},{"name":"1101103C","sw_key_expectedpath":"firmware"},{"name":"0701103C","sw_key_expectedpath":"firmware"},{"name":"0650103C","sw_key_expectedpath":"firmware"},{"name":"0601103C","sw_key_expectedpath":"firmware"},{"name":"0600103C","sw_key_expectedpath":"firmware"},{"name":"0651103C","sw_key_expectedpath":"firmware"},{"name":"0603103C","sw_key_expectedpath":"firmware"},{"name":"0652103C","sw_key_expectedpath":"firmware"},{"name":"1100103C","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"185259","datemodified":"2021-07-21T17:26:42","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-193.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"710c819bbf4523385a134b42c898f900","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:19:04","revision":"0","sha1sum":"37ab0a41078ab565404edf7adcc819f43b4b3c84","size":"180KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"185419","datemodified":"2021-07-21T17:29:20","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"753e60b12794d92d9b7fda725e0cc185","name":"kmod-hp-ixgbe_bl-5.9.4-2.rhel8u3.x86_64.rpm","release":"2021-07-21T17:19:04","revision":"0","sha1sum":"b35d40d8267c3fd8c64fd7abcfc1e47cb6cec747","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"6a2763c5a8ec446e809e71991d4253f9","version":"a4f2c3819b114b27943e712cdd50e15c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"218.0.303000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Ethernet NICs Boot code, PXE, NCSI, and CCM code running under VMware vSphere 6.5, vSphere 6.7 and vSphere 7.0"},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、vSphere 6.7、およびvSphere 7.0で動作するHPE ProLiant Broadcom NetXtreme-E Ethernet NICのブートコード、PXE、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"14310165","datemodified":"2022-02-07T10:08:57","file_list":["/CP050625_BUILD_4.data","/CP050625.vmexe","/CP050625.vmexe64","/CP050625.vmfile","/CP050625_VMw.zip","/CP050625.xml","/payload.json","/CP050625_VMw.zip/index.xml","/CP050625_VMw.zip/vendor-index.xml","/CP050625_VMw.zip/metadata.zip","/CP050625_VMw.zip/vib20/CP050625/HPE_bootbank_CP050625_5.14.1.4-7.0.0.15843807.vib","/CP050625_VMw.zip/metadata.zip/vendor-index.xml","/CP050625_VMw.zip/metadata.zip/vmware.xml","/CP050625_VMw.zip/metadata.zip/vibs/CP050625-8675715713331376987.xml","/CP050625_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050625_5.14.1.4-7.0.0.15843807.xml"],"md5sum":"54e17ef0d2ab25a2bd8d9abb423281cc","name":"CP050625.zip","release":"2022-02-07T10:08:03","revision":"0","sha1sum":"3d8b3ea935150731693735cea8d67473d99a193e","size":"13MB","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"5.14.1","vib_list":[{"name":"CP050625","version":"5.14.1.4-7.0.0.15843807"}]}],"id":{"product":"fdb3892daac8474c8262b342acf8f35f","version":"5f77f99da743446c8d44fe12092a7a77"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<li>VMwareコンポーネントをインストールします。\n\t<ul>\n\t\t<li>a. ESXi 7.0ターゲットの場合：esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<li>b. ESXi 6.xターゲットの場合：esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ul>\n\t</li>\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<li>必要に応じて、コマンドセットオプションs、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ul>\n\t\t<li>a. /opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<li>b. Smartコンポーネントをクリーンアップするには：\n\t\t<ul>\n\t\t\t<li>i. ESXi 7.0ターゲットの場合：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii. ESXi 6.xターゲットの場合：esxcli software vib remove –n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c. CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eオンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-22T05:25:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where network interface could not be brought up under VMWare.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue a packet missing problem after some amounts of multicast UDP streams transmitted.</li>\n\t<li>This product addresses an issue the port identifier LED problem on HPE Ethernet 10Gb 2-port 535T Adapter .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"BCM_NXE","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11249292","datemodified":"2022-03-10T22:03:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/CP051198.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/U45_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051198.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051198.scexe"],"md5sum":"155bac6f2bca13b632124d8599b225c2","name":"firmware-system-u45-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-10T21:56:30","revision":"0","sha1sum":"aec23c675dc25eef0d6b734841291fb20089f6ae","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"1f91b74faf084255b33a9e102dcf221d","version":"16c7a9e20f38474bb86b28fae1b4c2d7"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:13:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33601440","datemodified":"2022-03-08T12:54:52","file_list":["payload.json","U39_2.62_03_08_2022.signed.flash","U39_2.62_03_08_2022.xml"],"md5sum":"765082ed82ebc3e0a50b2690e15dbf4d","name":"U39_2.62_03_08_2022.fwpkg","release":"2022-03-08T12:50:41","revision":"0","sha1sum":"aa3f62593886d96dc0c7e525c7550ca57fe93f27","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"5410a19b6b464f26bd8935266bc1120d","version":"54016a9b01574851ae389a2b469f048a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T10:40:45","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"837464","datemodified":"2021-11-02T08:42:26","file_list":["cp047055.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"91dbf7676af1423b24ae1b51260885d9","name":"cp047055.exe","release":"2021-11-02T08:28:34","revision":"0","sha1sum":"ccf1c92515d1e2ad5cf39179cdb6c731421fcace","size":"817KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.241.0"}],"id":{"product":"7a409aa1e5444a57b8b10f884c98ae5f","version":"0f566376f25d43459c0d4397f72bbce7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInVXN.dll and vxnmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB1000GVYZE、MB2000GVYZF、MB3000GVYZHおよびMB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5287261","datemodified":"2021-07-23T06:08:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/CP048146.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/SMBPNTG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7010918e-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048146.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048146.scexe"],"md5sum":"03db0e2543ea3245862839b0c22c3ef2","name":"firmware-hdd-0a7010918e-HPG4-10.1.x86_64.rpm","release":"2021-07-23T05:56:08","revision":"0","sha1sum":"1b279240bcc073fc0d8f9829b7d83862eb268221","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"a436ff0616cd485d9ad02a8eddc12852","version":"5c9143dd6a644bafa0b425b7ef13562c"},"installation":{"command":"CP040311.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:36:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4083432","datemodified":"2021-07-23T06:50:57","file_list":["cp048547.xml","cpqsetup.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"md5sum":"24f1e5973bc4dff78016ca9c98e7d9dd","name":"cp048547.exe","release":"2021-07-23T06:43:05","revision":"0","sha1sum":"ed414e4985e5c9606aa2a853b58d60561ea12062","size":"3MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"63976963938d4f79be04f7b652abb966","version":"e0a349de03494ac58e51819e0dbd30d1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T14:59:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1145488","datemodified":"2021-11-02T10:43:34","file_list":["cp047050.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs65x64.cat","ixs65x64.din","ixs65x64.inf","ixs65x64.sys","ixsmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXS.dll"],"md5sum":"132e5f3c179f9c0bdbc7ed09c84c5223","name":"cp047050.exe","release":"2021-11-02T10:29:47","revision":"0","sha1sum":"f34dcdb0af38f968ba1df3b45307aa2673260d97","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e"],"type_of_change":"0","version":"4.1.239.0"}],"id":{"product":"b0ffbe90a5fd48a0bda67da833198a22","version":"9f201f2d01aa4043b3735c2dee732d48"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixs Driver for Windows Server 2016"},{"lang":"ja","x_late":"Windows Server 2016用HPE Intel ixsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXS.dll and ixsmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixs65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19771634","datemodified":"2021-08-30T05:11:10","file_list":["/CP049160_BUILD_2.data","/CP049160.vmexe","/CP049160.vmexe64","/CP049160.vmfile","/CP049160_VMw.zip","/CP049160.xml","/payload.json","/CP049160_VMw.zip/index.xml","/CP049160_VMw.zip/vendor-index.xml","/CP049160_VMw.zip/metadata.zip","/CP049160_VMw.zip/vib20/CP049160/HPE_bootbank_CP049160_HPG1.2-7.0.0.15843807.vib","/CP049160_VMw.zip/metadata.zip/vendor-index.xml","/CP049160_VMw.zip/metadata.zip/vmware.xml","/CP049160_VMw.zip/metadata.zip/vibs/CP049160--7393442737713041868.xml","/CP049160_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049160_HPG1.2-7.0.0.15843807.xml"],"md5sum":"45cd0e36ca4f7df9dd878fab042a52c5","name":"CP049160.zip","release":"2021-08-30T05:06:15","revision":"0","sha1sum":"744b3f04591cd26673cf31b6beb195846a2f1a4a","size":"18MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP049160","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"2f7da3629806488ebbb800b74a44db9d","version":"25f43da49b724c95982004c2de170ae8"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB,MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:47:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 7.0"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 7.0上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) ConnectX6アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28869364","datemodified":"2022-02-05T14:03:34","file_list":["/CP050421.vmexe64","/CP050421.vmfile","/CP050421.xml","/CP050421_VMw.zip","/payload.json","/README.txt","/CP050421_VMw.zip/index.xml","/CP050421_VMw.zip/vendor-index.xml","/CP050421_VMw.zip/metadata.zip","/CP050421_VMw.zip/vib20/CP050421/HPE_bootbank_CP050421_1.0.0-7.0.0.15525992.vib","/CP050421_VMw.zip/metadata.zip/vendor-index.xml","/CP050421_VMw.zip/metadata.zip/vmware.xml","/CP050421_VMw.zip/metadata.zip/vibs/CP050421-4431268642792800530.xml","/CP050421_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050421_1.0.0-7.0.0.15525992.xml"],"md5sum":"917120972ff6248edab43d4350861d29","name":"CP050421.zip","release":"2022-02-05T17:12:04","revision":"0","sha1sum":"5e6c6284038fc7dd4299c9279bacdbb577679bf1","size":"27MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050421","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"65eb20c47c2e478992fc3cbe0ecae5a8","version":"14f127be8a544b1db37ec4b89c375f7f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 7.0"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 7.0) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX6デバイス - VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T07:06:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21</p>\n\n<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot.&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n<strong>Additional Fixes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>\n\t<li>Improved PortXmitWait IB counter accuracy.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 20.32.1010:</strong></p>\n\n<ul>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li>\n</ul>\n\n<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. If case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit per-host per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n\t<li>Limited the external loopback speed according to the used module&#39;s capabilities.</li>\n\t<li>Modified the Effective BER calculation method. Due to this, the value of the Effective BER will be slightly higher, however the link quality remains the same as prior to this change.</li>\n\t<li>This firmware version includes the following PCIe changes:\n\t<ul>\n\t\t<li>Fixed the ACS Port Number field in DSPs and ACS Egress Control Vector field in DSPs.</li>\n\t\t<li>Added support for VSC on USP of PCIe Switch.</li>\n\t\t<li>Fixed the mapping of Legacy Interrupts in the PCIe Switch.</li>\n\t\t<li>Fixed MRRS &amp; MPS configurations in DSPs.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>System could not create more than 128K QPs.</li>\n\t<li>Incorrect indication of the PCIe link down in the AER registers on PCIe switch upstream port.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The flash frequency on boot was lower than expected (under 50Mhz). The issue was fixed by enabling the firmware to increase it on boot2 to normal frequency.</li>\n\t<li>A race condition between DC QP flush and DC packets that led to stuck slices in the hardware. To avoid such situation, firmware keeps the TCU drop set until QP flush is done.</li>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.46.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.46"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2226600","datemodified":"2022-01-12T14:53:29","file_list":["cp050719.xml","cpqsetup.exe","payload.json","setup.dll","UBM1_V1.46.hex.fw"],"md5sum":"a7ee50219930ac991fe1990fc4d4ef44","name":"cp050719.exe","release":"2022-01-12T14:44:52","revision":"0","sha1sum":"09e95d6d9d6525f4c82cb797b10b9b00d2c5245a","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.46"}],"id":{"product":"fed7882585434512b7259db2ba5790f0","version":"d0dc1c8b40bc400da4d2dd531348f65b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM1 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10Plus UBM1 バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-06T06:18:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add Microsoft Windows 2022 to OS supported lists.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initil Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR416i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-p_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR416i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7491260","datemodified":"2021-09-08T14:49:07","file_list":["HPE_MR416i-p_Gen10P_52.16.3-3913.ilo","HPE_MR416i-p_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"114c7178d45a4ea9d5c5cd16392b6abe","name":"HPE_MR416i-p_Gen10P_52.16.3-3913.fwpkg","release":"2021-09-08T14:45:36","revision":"0","sha1sum":"88d318125047c3f8f541b94d6128a0b611e39979","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e215900293"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"3f857d7b01734aa494f8146516002d2e","version":"0b0717878ae0494aa4d4811cfa3694d3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR416i-p Gen10 Plusトライモードコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T14:14:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"02931590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11640400","datemodified":"2022-03-08T10:03:39","file_list":["cp051159.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_2.62_03_08_2022.signed.flash"],"md5sum":"0bdaccf88928e475f3482648023e8824","name":"cp051159.exe","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"3f3e3633c1e6afce63db762615abe4422c18c0ac","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"cfa8fbdb2f4a4c81b7b1ee3f89f284e0","version":"4843d364f743411e8135f77e11ad8b76"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows x64 的線上 ROM 更新元件 - HPE ProLiant DL380 Gen10 (U30) 伺服器"},{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ko","x_late":"Windows x64용 온라인 ROM 플래시 구성 요소 - HPE ProLiant DL380 Gen10 (U30) 서버"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL380 Gen10 (U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPK および EH000600JWHPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPK and EH000600JWHPH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16172826","datemodified":"2021-08-27T18:44:30","file_list":["/CP049135_BUILD_1.data","/CP049135.vmexe","/CP049135.vmexe64","/CP049135.vmfile","/CP049135_VMw.zip","/CP049135.xml","/payload.json","/CP049135_VMw.zip/index.xml","/CP049135_VMw.zip/vendor-index.xml","/CP049135_VMw.zip/metadata.zip","/CP049135_VMw.zip/vib20/CP049135/HPE_bootbank_CP049135_HPD7.1-7.0.0.15843807.vib","/CP049135_VMw.zip/metadata.zip/vendor-index.xml","/CP049135_VMw.zip/metadata.zip/vmware.xml","/CP049135_VMw.zip/metadata.zip/vibs/CP049135-1399980518082995242.xml","/CP049135_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049135_HPD7.1-7.0.0.15843807.xml"],"md5sum":"469ca42384224989a671e0fe287ca11a","name":"CP049135.zip","release":"2021-08-27T18:39:17","revision":"0","sha1sum":"2272a93645c426ae1ba8ecb14541609fb29c3aaa","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP049135","version":"HPD7.1-7.0.0.15843807"}]}],"id":{"product":"f7d7f54393d44f66845199e26d4e5900","version":"1d52f2fc65614fe9915bcfedff39a917"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"},{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:24:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a condition that could cause the heads to land on the media in an emergency power off situation, and another condition that can lead to high-fly write, and eliminates a command timeout issue. Some internal logging operations were refined at the same time.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWBHR"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWBHR Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16238653","datemodified":"2021-09-24T10:09:20","file_list":["/CP048248_BUILD_2.data","/CP048248.vmexe","/CP048248.vmexe64","/CP048248.vmfile","/CP048248_VMw.zip","/CP048248.xml","/payload.json","/CP048248_VMw.zip/index.xml","/CP048248_VMw.zip/vendor-index.xml","/CP048248_VMw.zip/metadata.zip","/CP048248_VMw.zip/vib20/CP048248/HPE_bootbank_CP048248_HPD5.2-7.0.0.15843807.vib","/CP048248_VMw.zip/metadata.zip/vendor-index.xml","/CP048248_VMw.zip/metadata.zip/vmware.xml","/CP048248_VMw.zip/metadata.zip/vibs/CP048248-1721123927654259357.xml","/CP048248_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048248_HPD5.2-7.0.0.15843807.xml"],"md5sum":"9668b7b56f2d5922edadbed735cea20d","name":"CP048248.zip","release":"2021-09-24T10:03:19","revision":"0","sha1sum":"9746e5b02dcd98abcfdae8baf882a25e0a211eae","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048248","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"2a7080d78048494dac265180eef80ae1","version":"7886b4a69c3644d2980cf46552a4ae55"},"installation":{"command":"CP040530.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T05:04:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VR000150GWEPP および VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2834256","datemodified":"2021-07-22T10:08:58","file_list":["4IDMHPG1.rel","cp048647.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"1050d238e4694b11404046732105e44f","name":"cp048647.exe","release":"2021-07-22T10:01:04","revision":"0","sha1sum":"d3c24cea2fad57c066c7779132a5722df51ccdf4","size":"2MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"7a5bb5126715458dbee6bc8ea5d0f887","version":"f475a3589fea402694029e839c9be596"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:19:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.46.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.46"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM1ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3949668","datemodified":"2022-01-12T14:54:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/CP050720.xml","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/UBM1_V1.46.hex.fw","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-b303c4dfec-1.46-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050720.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050720.scexe"],"md5sum":"5ab213a4a961fc062aa81baa6c2440b5","name":"firmware-b303c4dfec-1.46-1.1.x86_64.rpm","release":"2022-01-12T14:39:35","revision":"0","sha1sum":"ad203fc14c1f36c767cb885c338810a7f151544a","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.46"}],"id":{"product":"314bc817543f4e91a4b234b38c27ef87","version":"63f2bb14b025483eb1e50984c4260578"},"installation":{"command":"CP050720.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><em><strong>Updating firmware with rpm installed:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; rpm -ivh &lt;rpm_filename&gt;.&nbsp; This extracts the contents of the rpm to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP049221.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-2e20068436-*&#39; folder is based on the version of the rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./ CP049221.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp; &nbsp;&nbsp; # ./setup in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-2e20068436-*&#39; location</p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the &#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-2e20068436-*&#39; location and run ./setup to update the firmware. The actual name of the &#39;firmware-smartarray-2e20068436-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp; It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the above outlined steps</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Linux - Gen10Plus UBM1 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Linux - Gen10Plus UBM1バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-06T06:24:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Correct device GUID.</p>\n"},{"curr_enhancements_x_late":"<p>Inital Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1230284","datemodified":"2021-07-21T18:01:13","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-193.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"14f7a10ca482827811a22d58507ca30b","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-07-21T17:48:16","revision":"0","sha1sum":"51762eb23aa12f71a7ff87ef097ded3f75685fa3","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1265967","datemodified":"2021-07-21T18:00:01","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi","./lib/modules/4.18.0-240.el8.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"6498f0c109c54f627a64c960b195844b","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-07-21T17:48:16","revision":"0","sha1sum":"56420cc902899660391120b34178c34318307995","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"29dd95234723495d9d82f8b70f154b42","version":"8e41003a62b545a1b578fa505fc54f60"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8, Updates 2&nbsp;and 3.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000GWKGV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000GWKGV Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4269304","datemodified":"2021-07-23T19:06:04","file_list":["cp048561.xml","cpqsetup.exe","HVLAnAaseFG1.rel","payload.json","setup.dll"],"md5sum":"d0f63565215083b13c1399668dfd6241","name":"cp048561.exe","release":"2021-07-23T18:58:13","revision":"0","sha1sum":"5510641f3e74fdc98f0a4377c0ee1b83f303587e","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-3047574b4756"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"0d61334622ba44aeb0c163514d9f57b9","version":"3be45915be674a4699b3b60eb6c9a576"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB004000GWKGVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000GWKGV","target_guid":"4d2340a5-3042-3430-3030-3047574b4756","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:24:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWKGV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_3p00_NCSIwPLDMoMCTP_80008265.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA2 OCP3 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-XXVDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter</td>\n\t\t\t<td>80008265</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>he combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t\t<th>NVMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター</td>\n\t\t\t<td>80008265</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2992.0は以下を含みます：インテル(R)ブートエージェントICE v2.5.0およびUEFI x64 100ギガビットドライバーv3.0.11。</p>\n"}],"files":[{"bytes":"10518786","datemodified":"2021-08-12T14:09:03","file_list":["HPE_E810_XXVDA2_SD_OCP_3p00_NCSIwPLDMoMCTP_80008265.HPb","HPE_E810_XXVDA2_SD_OCP_3p00_NCSIwPLDMoMCTP_80008265.xml","payload.json"],"md5sum":"b87eca07fdcbed512151291e66c646b9","name":"HPE_E810_XXVDA2_SD_OCP_3p00_NCSIwPLDMoMCTP_80008265.fwpkg","release":"2021-09-16T00:00:00","revision":"1","sha1sum":"ca18165adb68cf700b7eb0c825fcfa35bcccf192","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159b80860005"],"type_of_change":"1","version":"3.00"}],"id":{"product":"fbb53cf22a594dbb99b8c7f89e562124","version":"902ded71c5184847af5c92c2ffb80f38"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-XXVDA2 Ethernet 10/25Gb 2ポートSFP28 OCP3アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T08:47:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_XXV2OCP_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>AAdded support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2809080","datemodified":"2021-07-25T18:39:02","file_list":["cp048637.xml","cpqsetup.exe","GP863aG3.rel","payload.json","setup.dll"],"md5sum":"fc15203a89364227630c97ee97810d0d","name":"cp048637.exe","release":"2021-07-25T18:31:05","revision":"0","sha1sum":"b2f639251fc7434a650e32862d3af37699e74c4d","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3030-3234-304757434644","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"539ed4e104fc49caac711d8c4da1d36a","version":"58160388743c44bb9c5c0cb6c706468f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFHおよびVK003840GWCFKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:40:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JFJTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a464a5448","Version":"HPD4"},{"DeviceName":"MM002000JWCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304d-3230-3030-304a57434e46","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JFJTH and MM002000JWCNF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH and MM002000JWCNF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3551088","datemodified":"2021-07-25T17:25:10","file_list":["cp048626.xml","cpqsetup.exe","payload.json","SAVGNSD4.rel","setup.dll"],"md5sum":"ac66ba31081b8009d2c02b54e12c6698","name":"cp048626.exe","release":"2021-07-25T17:18:14","revision":"0","sha1sum":"63d7a54ac6c3ece2fccef30cad4598077269d64f","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a464a5448","4d2340a5-304d-3230-3030-304a57434e46"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"05aa24e5db0c41fc91f79deb60685a31","version":"5702fac0a5bb4870aaed71fec0392142"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JFJTH and MM002000JWCNF Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JFJTH","target_guid":"002340a5-4d00-314d-3030-304a464a5448","type":"sas"},{"id":"MM002000JWCNF","target_guid":"4d2340a5-304d-3230-3030-304a57434e46","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:34:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM002000JWCNF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JFJTH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) device firmware on Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）デバイスファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"2890672","datemodified":"2020-11-12T07:52:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/CP045906.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045906.scexe"],"md5sum":"5c3c1937c3187c46524a9f5c237e963b","name":"firmware-hca-mellanox-vpi-eth-ib-1.0.12-1.1.x86_64.rpm","release":"2020-11-12T07:49:07","revision":"0","sha1sum":"d05404b3fa1e19acbcaeb33b2bef7b17802a0e52","size":"2MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.12"}],"id":{"product":"d0d15d83c7a84846a84195d46ef502f4","version":"bd2c2b5bb3894999be9e6352b3ce9436"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於執行 Linux x86_64 平台的 HPE Mellanox VPI (Ethernet 與 Infiniband 模式) 裝置的線上韌體升級公用程式 (Linux x86_64)"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Linux x86_64 platform"},{"lang":"ko","x_late":"Linux x86_64 플랫폼의 HPE Mellanox VPI(이더넷 및 Infiniband 모드) 장치용 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于Linux x86_64平台上的HPE Mellanox VPI（Ethernet和Infiniband模式）设备的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Linux x86_64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Linux x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GXAWE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304758415745","Version":"HPG1"},{"DeviceName":"VK000480GXAWK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475841574b","Version":"HPG1"},{"DeviceName":"VK000960GXAWL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475841574c","Version":"HPG1"},{"DeviceName":"VK001920GXAWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475841574e","Version":"HPG1"},{"DeviceName":"VK003840GXAWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758415750","Version":"HPG1"},{"DeviceName":"VK007680GXAWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758415751","Version":"HPG1"},{"DeviceName":"MK000480GXAWF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304758415746","Version":"HPG1"},{"DeviceName":"MK000960GXAXB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304758415842","Version":"HPG1"},{"DeviceName":"MK001920GXAWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304758415752","Version":"HPG1"},{"DeviceName":"MK003840GXAWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304758415754","Version":"HPG1"},{"DeviceName":"VR000240GXBBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3234-30475842424c","Version":"HPG1"},{"DeviceName":"MR000480GXBGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304758424748","Version":"HPG1"},{"DeviceName":"MR000960GXBGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5300AG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-30475842474b","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4734656","datemodified":"2021-07-27T15:54:42","file_list":["cp049159.xml","cpqsetup.exe","M5300AG1.rel","payload.json","setup.dll"],"md5sum":"9c47eaab0a878da81af4d7198ef04c93","name":"cp049159.exe","release":"2021-07-27T15:47:06","revision":"0","sha1sum":"ed77f775efe66739b75801e7cff410ec9ed5160a","size":"4MB","target_guids":["562340a5-304b-3030-3234-304758415745","562340a5-304b-3030-3438-30475841574b","562340a5-304b-3030-3936-30475841574c","562340a5-304b-3130-3932-30475841574e","562340a5-304b-3330-3834-304758415750","562340a5-304b-3730-3638-304758415751","4d2340a5-304b-3030-3438-304758415746","4d2340a5-304b-3030-3936-304758415842","4d2340a5-304b-3130-3932-304758415752","4d2340a5-304b-3330-3834-304758415754","562340a5-3052-3030-3234-30475842424c","4d2340a5-3052-3030-3438-304758424748","4d2340a5-3052-3030-3936-30475842474b"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3e81763b3821481db4fe370a0e06c011","version":"dc8bd0a7ea0e4e7da3154af323d7bebf"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl　\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GXAWE, VK000480GXAWK, VK000960GXAWL, VK001920GXAWN, VK003840GXAWP, VK007680GXAWQ, MK000480GXAWF, MK000960GXAXB, MK001920GXAWR, MK003840GXAWT, VR000240GXBBL, MR000480GXBGH and MR000960GXBGK  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GXAWE、VK000480GXAWK、VK000960GXAWL、VK001920GXAWN、VK003840GXAWP、VK007680GXAWQ、MK000480GXAWF、MK000960GXAXB、MK001920GXAWR、MK003840GXAWT、VR000240GXBBL、MR000480GXBGH、およびMR000960GXBGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MR000960GXBGK","target_guid":"4d2340a5-3052-3030-3936-30475842474b","type":"sata"},{"id":"MR000480GXBGH","target_guid":"4d2340a5-3052-3030-3438-304758424748","type":"sata"},{"id":"VR000240GXBBL","target_guid":"562340a5-3052-3030-3234-30475842424c","type":"sata"},{"id":"MK003840GXAWT","target_guid":"4d2340a5-304b-3330-3834-304758415754","type":"sata"},{"id":"MK001920GXAWR","target_guid":"4d2340a5-304b-3130-3932-304758415752","type":"sata"},{"id":"MK000960GXAXB","target_guid":"4d2340a5-304b-3030-3936-304758415842","type":"sata"},{"id":"MK000480GXAWF","target_guid":"4d2340a5-304b-3030-3438-304758415746","type":"sata"},{"id":"VK007680GXAWQ","target_guid":"562340a5-304b-3730-3638-304758415751","type":"sata"},{"id":"VK003840GXAWP","target_guid":"562340a5-304b-3330-3834-304758415750","type":"sata"},{"id":"VK000960GXAWL","target_guid":"562340a5-304b-3030-3936-30475841574c","type":"sata"},{"id":"VK000480GXAWK","target_guid":"562340a5-304b-3030-3438-30475841574b","type":"sata"},{"id":"VK000240GXAWE","target_guid":"562340a5-304b-3030-3234-304758415745","type":"sata"},{"id":"VK001920GXAWN","target_guid":"562340a5-304b-3130-3932-30475841574e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:42:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>The updates were included in a regularly scheduled 5300 maintenance release. This firmware has a security version upgrade to include TCGe SKUs and prevent a downloading of a back level firmware version of HPG0 after upgrading to HPG1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GXAWR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GXAWT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000240GXBBL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GXAWP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GXBGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GXAWK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GXAXB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GXAWE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXAWL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXAWN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXAWQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GXAWF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000480GXBGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JFHMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a46484d48","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JFHMH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG1800JFHMH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3034264","datemodified":"2021-07-24T06:11:09","file_list":["cp048509.xml","cpqsetup.exe","payload.json","setup.dll","T14SEED8.rel"],"md5sum":"45e41a2f3778be17bed60deeeca2f6b8","name":"cp048509.exe","release":"2021-07-24T06:03:05","revision":"0","sha1sum":"4a714ad21a887bac0d8cd35e1dfb9b22f346f1bf","size":"2MB","target_guids":["002340a5-4500-3147-3830-304a46484d48"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"cb2be7d18951448db0daf6ce3cff2a1c","version":"856e89204d034a4da3f91e38db3be942"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JFHMH Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JFHMHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JFHMH","target_guid":"002340a5-4500-3147-3830-304a46484d48","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:36:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JFHMH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG001800JWFVC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16256592","datemodified":"2021-08-31T05:56:21","file_list":["/CP048253_BUILD_2.data","/CP048253.vmexe","/CP048253.vmexe64","/CP048253.vmfile","/CP048253_VMw.zip","/CP048253.xml","/payload.json","/CP048253_VMw.zip/index.xml","/CP048253_VMw.zip/vendor-index.xml","/CP048253_VMw.zip/metadata.zip","/CP048253_VMw.zip/vib20/CP048253/HPE_bootbank_CP048253_HPD4.2-7.0.0.15843807.vib","/CP048253_VMw.zip/metadata.zip/vendor-index.xml","/CP048253_VMw.zip/metadata.zip/vmware.xml","/CP048253_VMw.zip/metadata.zip/vibs/CP048253--7086440309689431666.xml","/CP048253_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048253_HPD4.2-7.0.0.15843807.xml"],"md5sum":"94529813da19c3f61d025358387b4376","name":"CP048253.zip","release":"2021-08-31T05:51:35","revision":"0","sha1sum":"d613aafc3c98840ddab1641f01a4aefb172b0a25","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048253","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"f651d51d32bf48dca96b23a2b4fb67f4","version":"4fd3ba946e1c4a4e9c949c20259cc4c0"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG001800JWFVC ライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T08:04:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8761579","datemodified":"2021-08-25T09:15:42","file_list":["/CP046776_BUILD_4.data","/CP046776.vmexe","/CP046776.vmexe64","/CP046776.vmfile","/CP046776_VMw.zip","/CP046776.xml","/payload.json","/CP046776_VMw.zip/index.xml","/CP046776_VMw.zip/vendor-index.xml","/CP046776_VMw.zip/metadata.zip","/CP046776_VMw.zip/vib20/CP046776/HPE_bootbank_CP046776_2021.09.01.4-6.5.0.4240417.vib","/CP046776_VMw.zip/metadata.zip/vendor-index.xml","/CP046776_VMw.zip/metadata.zip/vmware.xml","/CP046776_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046776_2021.09.01.4-6.5.0.4240417.xml","/CP046776_VMw.zip/metadata.zip/vibs/CP046776-2452417873030035896.xml"],"md5sum":"06835564c4de5d4903cc888eb21edaf2","name":"CP046776.zip","release":"2021-08-25T09:10:05","revision":"0","sha1sum":"379bf419ab60ad664870cebe0ca0f804e63986cf","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046776","version":"2021.09.01.4-6.5.0.4240417"}]}],"id":{"product":"da71eb7a509c42f8b6a612623341578e","version":"197701c617d54726981d51f2849f258f"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a behavior where the Unified Extensible Firmware Interface (UEFI) driver would force the system to reboot if one or both ports of a mezzanine adapter were not connected to an interconnect module during boot.</li>\n\t<li>Fixed a behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK003840GWSXL Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK003840GWSXLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5009456","datemodified":"2021-07-23T08:54:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/CP048190.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/M52004G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048190.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048190.scexe"],"md5sum":"058876447f31018e1c135b3d98e65b3f","name":"firmware-hdd-d1cf327bc4-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:42:10","revision":"0","sha1sum":"7b9ad6e9268723877b47b62f3b10b645cc0a2a11","size":"4MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"26ad6199e9ca4196942c2e37e82e08a2","version":"9722a9db66f3424fae82a30d174dec06"},"installation":{"command":"CP040779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK003840GWSXLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:11:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD2"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD2"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD2"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD2"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD2"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD2"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD2"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD2"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD2"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD2"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD2"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6ALLHPD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n      オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EO000400PXDBQ、EO000800PXDCK、EO001600PXDCH、MO000800PXDBP、MO001600PXDCC、MO003200PXDCD、MO006400PXDCE、VO000960PXDBN、VO001920PXDBR、VO003840PXDBT、VO007680PXDBU、およびVO015300PXDBVドライブ<br />\n<br />\n<strong>リリースバージョンおよび/または日付：</strong><br />\n      HPD2<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n      HPD1<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n      HPD1<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n      なし  </p>\n\n<p><strong>改善点/新しい機能：</strong></p>\n\n<p>      なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"17685752","datemodified":"2021-12-17T09:21:11","file_list":["/CP050382_BUILD_1.data","/CP050382.vmexe","/CP050382.vmexe64","/CP050382.vmfile","/CP050382_VMw.zip","/CP050382.xml","/payload.json","/CP050382_VMw.zip/index.xml","/CP050382_VMw.zip/vendor-index.xml","/CP050382_VMw.zip/metadata.zip","/CP050382_VMw.zip/vib20/CP050382/HPE_bootbank_CP050382_HPD2.1-7.0.0.15843807.vib","/CP050382_VMw.zip/metadata.zip/vendor-index.xml","/CP050382_VMw.zip/metadata.zip/vmware.xml","/CP050382_VMw.zip/metadata.zip/vibs/CP050382--4018516077011111937.xml","/CP050382_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050382_HPD2.1-7.0.0.15843807.xml"],"md5sum":"1f6815e040018a29b1969819e920bc27","name":"CP050382.zip","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"e026915e8aea42b914bd9ebf5436b8a39f611aab","size":"16MB","target_guids":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP050382","version":"HPD2.1-7.0.0.15843807"}]}],"id":{"product":"cd1eb2802ed24b6aa04d98effb166b0e","version":"009d259df3974862a8eddf13db2edf98"},"installation":{"command":"CP042550.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EO000800PXDCK","target_guid":"452340a5-304f-3030-3830-30505844434b","type":"sas"},{"id":"MO000800PXDBP","target_guid":"4d2340a5-304f-3030-3830-305058444250","type":"sas"},{"id":"EO000400PXDBQ","target_guid":"452340a5-304f-3030-3430-305058444251","type":"sas"},{"id":"EO001600PXDCH","target_guid":"452340a5-304f-3130-3630-305058444348","type":"sas"},{"id":"MO001600PXDCC","target_guid":"4d2340a5-304f-3130-3630-305058444343","type":"sas"},{"id":"MO006400PXDCE","target_guid":"4d2340a5-304f-3630-3430-305058444345","type":"sas"},{"id":"VO007680PXDBU","target_guid":"562340a5-304f-3730-3638-305058444255","type":"sas"},{"id":"VO001920PXDBR","target_guid":"562340a5-304f-3130-3932-305058444252","type":"sas"},{"id":"VO015300PXDBV","target_guid":"562340a5-304f-3531-3330-305058444256","type":"sas"},{"id":"MO003200PXDCD","target_guid":"4d2340a5-304f-3330-3230-305058444344","type":"sas"},{"id":"VO000960PXDBN","target_guid":"562340a5-304f-3030-3936-30505844424e","type":"sas"},{"id":"VO003840PXDBT","target_guid":"562340a5-304f-3330-3834-305058444254","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T10:53:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680PXDBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600PXDCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920PXDBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800PXDCK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200PXDCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840PXDBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300PXDBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960PXDBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600PXDCC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400PXDBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400PXDCE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800PXDBP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"17518901","datemodified":"2021-08-30T06:42:08","file_list":["/CP048292_BUILD_2.data","/CP048292.vmexe","/CP048292.vmexe64","/CP048292.vmfile","/CP048292_VMw.zip","/CP048292.xml","/payload.json","/CP048292_VMw.zip/index.xml","/CP048292_VMw.zip/vendor-index.xml","/CP048292_VMw.zip/metadata.zip","/CP048292_VMw.zip/vib20/CP048292/HPE_bootbank_CP048292_HPD6.2-7.0.0.15843807.vib","/CP048292_VMw.zip/metadata.zip/vendor-index.xml","/CP048292_VMw.zip/metadata.zip/vmware.xml","/CP048292_VMw.zip/metadata.zip/vibs/CP048292--3310962060742691239.xml","/CP048292_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048292_HPD6.2-7.0.0.15843807.xml"],"md5sum":"da3ccd14e2785f8dd5a7da8e60bed85d","name":"CP048292.zip","release":"2021-08-30T06:37:04","revision":"0","sha1sum":"758f0f3b1e01238b137c85e666ac93b179338d33","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048292","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"2311760d35054ca48230493dff4b743b","version":"76c8094b7d2b4dd4a5e077f3d1c942a1"},"installation":{"command":"CP042726.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T07:31:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Smart Array SR Event Notification Service provides event notification to the 64-bit Microsoft Windows Server system event log for systems using the HPE Smart Array SR controller driver."},{"lang":"ja","x_late":"HPE SmartアレイイSRベント通知サービスは、HPE SmartアレイSRコントローラードライバーを使用しているシステムで、64ビットMicrosoft Windows Serverシステムイベントログへのイベント通知をサポートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"701152","datemodified":"2021-08-23T09:30:52","file_list":["cp049025.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"md5sum":"9143285b4d9fb692fae3bab96b4091bf","name":"cp049025.exe","release":"2021-08-23T09:29:05","revision":"0","sha1sum":"ecefd80428167bc2bce75eb6f6881a2c2fb14d77","size":"684KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"type_of_change":"1","version":"1.2.1.66"}],"id":{"product":"ccde97956825448f97ee8427bc2eccdb","version":"8790b6b8748f48c6b5b37192bc2f53d3"},"installation":{"command":"cpqsetup.exe","command_params":"/verbose_log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"63.32.0.64","description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update."}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"62.0.28.64","description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update."}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions"},{"lang":"ja","x_late":"Windows Server 64ビットEditions向けHPE SmartアレイSRベント通知サービス "}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-19T07:35:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Fixed for the version information</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpepqiesrv.exe","sw_key_expectedpath":"%programfiles%\\hpe\\hpepqiesrv"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWEBH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57454248","Version":"HPD5"},{"DeviceName":"EG000300JWEBF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBUGD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57454246","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWEBH and EG000300JWEBF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWEBHおよびEG000300JWEBF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000600JWEBH and EG000300JWEBF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3659584","datemodified":"2021-08-25T12:02:22","file_list":["cp049346.xml","cpqsetup.exe","payload.json","setup.dll","STHBUGD5.rel"],"md5sum":"03ab5c70923d2b842f50fc90bf04201e","name":"cp049346.exe","release":"2021-08-25T11:54:05","revision":"0","sha1sum":"37706cde029154ff6cf591d1bc2e16613c5019d1","size":"3MB","target_guids":["452340a5-3047-3030-3630-304a57454248","452340a5-3047-3030-3330-304a57454246"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"4ac05ec48f5041978979616c09c3b9fb","version":"2bef34203faf4c608eb62a09275a5b7a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWEBH and EG000300JWEBF Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor Windows (x64) -  EG000600JWEBHおよびEG000300JWEBFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWEBF","target_guid":"452340a5-3047-3030-3330-304a57454246","type":"sas"},{"id":"EG000600JWEBH","target_guid":"452340a5-3047-3030-3630-304a57454248","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T11:50:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000600JWEBH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWEBF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"16611448","datemodified":"2022-01-21T02:49:26","file_list":["CHIF/","CHIF/X64/","cp039984.exe","cp039985.exe","cp040013.exe","cp041932.exe","cp049467.exe","cp049603.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"md5sum":"f323f54aa78669a4a4d69822744a6ee3","name":"cp049603.exe","release":"2022-01-21T02:45:25","revision":"0","sha1sum":"860b0052ea69f6bb789b3e6558c315ebf850605a","size":"15MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f36672a","20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"type_of_change":"1","version":"2.9.1.0"}],"id":{"product":"8fe22752c5324386870794853904b4ba","version":"f4a1c8d7962c46a6a221d9e9ea5edb02"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ol>\n\t<li>Download the Smart Component (cpxxxxxx.exe) file to a local directory on the server where you want to install the software.</li>\n\t<li>Change to the directory.</li>\n\t<li>Run the .exe file by double-clicking it. A dialog box will display.</li>\n\t<li>Click the &lsquo;Install&rsquo; button to install the Smart Update Tools.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Windows x64"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-21T09:13:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hpsut.exe","sw_key_expectedpath":"%ProgramFiles%\\Hewlett-Packard\\HPSUT\\bin"},{"name":"sut.exe","sw_key_expectedpath":"%ProgramFiles%\\SUT\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3305440","datemodified":"2021-07-25T21:46:57","file_list":["cp048665.xml","cpqsetup.exe","GPM1643SAMD8.rel","payload.json","setup.dll"],"md5sum":"8d0d1c5d4eeb9b8fec78895b8a7d2999","name":"cp048665.exe","release":"2021-07-25T21:38:04","revision":"0","sha1sum":"55767bd23f6b31034b18be934debe48d18c710c4","size":"3MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"b5c5978ca68a42089c65763237c54346","version":"716d77bbe8b04280b310ef5e686623fc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:15:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050885.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.062"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8565771","datemodified":"2022-01-26T08:51:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/CP050888.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/cp050885.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/cp050885.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.062-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050888.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050888.scexe"],"md5sum":"5307e7975b8a4923d4cae0c921d451e7","name":"firmware-spsgen10plus-04.04.04.062-1.1.x86_64.rpm","release":"2022-01-26T08:46:38","revision":"0","sha1sum":"e4e20b70ecfcc253ff9b2f84fbd91dfc7127a8c6","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.062"}],"id":{"product":"78667359eec84fc9af9066672db940e0","version":"b7032efa66c74e889e92fe5ac6f9f7eb"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T08:44:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added support for Intel Optane Persistent Memory.</p><p><strong>Known Issues:</strong></p>None","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version of the System ROM contains updates aligned with the INTEL Whitley BKC WW52.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"SPS_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"107723","datemodified":"2021-01-14T07:51:58","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2net","./lib/modules/4.12.14-94.41-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"0da27091401168305cd9b64632d224b2","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"e586b0a32baad96de832d1d4cd60764a48bfac68","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"107567","datemodified":"2021-01-14T07:49:25","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2net","./lib/modules/4.12.14-120-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"27462c794d5e4f8915ccae7af6fcf256","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:43:08","revision":"0","sha1sum":"22b22383cfca5ef17ec987ac8a57ef81fa662a22","size":"105KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"09591d5b70d148ae85b720d091645e6c","version":"e1817901830848a0aea1e2e157a47a7a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1038696","datemodified":"2021-09-28T04:32:26","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp047876.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"e21e55a694b98f9011cd40b94ad76a7b","name":"cp047876.exe","release":"2021-09-28T04:16:21","revision":"0","sha1sum":"3b27739e08632f509d0b6bad90fcdd8ec7d25c88","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"219.0.44.0"}],"id":{"product":"ed7a5d4d2f9c4a55ba7dea78369f1389","version":"16beaebb82394d9a9e3386864ee40737"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp040071.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.20"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"\n This component provides updated IE firmware that can be installed directly on supported Operating Systems.\n "},{"lang":"ja","x_late":"\n このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたIEファームウェアを提供します。\n "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8556534","datemodified":"2021-04-06T06:42:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/CP040069.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/cp040071.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/cp040071.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP040069.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP040069.scexe"],"md5sum":"ab15546d24db739ef8fe0066f4c5b549","name":"firmware-iegen10plus-1.0.0.20-1.1.x86_64.rpm","release":"2021-06-10T00:00:00","revision":"1","sha1sum":"cfbdd0b7b8282705fc92bc1d7df4ba196278b3f0","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000303"],"type_of_change":"1","version":"1.0.0.20"}],"id":{"product":"03c87662bb3a4a57a852807a8f77de3f","version":"fa0cb32d31ab40a7853551446bdcb7f5"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p><br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - HPE Gen10 Plus Innovation Engineファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-18T08:40:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This is the initial version of the firmware.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"IE-Gen10Plus","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050853.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2165662","datemodified":"2022-01-26T05:58:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/CP050858.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/cp050853.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/cp050853.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.04.400-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050858.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050858.scexe"],"md5sum":"178e8312ad9887e053e24985834c8b6c","name":"firmware-microservergen10plussps-05.01.04.400-1.1.x86_64.rpm","release":"2022-01-26T05:53:36","revision":"0","sha1sum":"fe92d66976ce52ccb259a7d69ae8c6d7f94fd0bf","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"667c48761fdd439199126de11a3666a8","version":"45cb7d73f2ce444ca0ae4196dd34b04a"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>Verify the RPM signature using the following steps:</strong></p>\n\n<p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p>\n\n<p>Import the public key while logged in as root by running the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>Verify the RPM:</strong></p>\n\n<p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p>\n\n<p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p>\n\n<p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p>\n\n<p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p>\n\n<p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p><strong>次の手順を使用してRPM署名を確認します:</strong></p>\n\n<p>HPE GPG 2048ビット公開キー（hpePublicKey2048_key1.pub）をダウンロードします。これは、HPE SDR Webサイトから入手できます：https://downloads.linux.hpe.com/keys.html</p>\n\n<p>rootとしてログイン中に、次のコマンドを実行して公開鍵をインポートします:</p>\n\n<p>   # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>   例 # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>RPMを検証します：</strong></p>\n\n<p>rpm-checksigコマンドを使用して、署名済みファイルのデジタル署名を確認します。コマンドからの出力は、署名の有効性を示しています：</p>\n\n<p>   # rpm --checksig filename_of_the_rpm</p>\n\n<p>   example result #  rpm --checksig <filename>.rpm</p>\n\n<p>  <filename>.rpm: digests signatures OK</p>\n\n<p>ファイルが検証に合格しない場合、またはHewlett Packard Enterpriseの公開キーがインストールされていない場合、エラーが表示される場合があります：</p>\n\n<p>   # rpm --checksig sample_file.rpm</p>\n\n<p>   sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>この場合は、rpmをインストールしないでください。これは、ファイルがHewlett Packard Enterprise Companyからリリースされて以降、何らかの方法で変更されたことを意味します。</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:01:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB008000JWJRQ_MB006000JWJRP&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16237838","datemodified":"2021-08-26T10:27:04","file_list":["/CP049132_BUILD_2.data","/CP049132.vmexe","/CP049132.vmexe64","/CP049132.vmfile","/CP049132_VMw.zip","/CP049132.xml","/payload.json","/CP049132_VMw.zip/index.xml","/CP049132_VMw.zip/vendor-index.xml","/CP049132_VMw.zip/metadata.zip","/CP049132_VMw.zip/vib20/CP049132/HPE_bootbank_CP049132_HPD9.2-7.0.0.15843807.vib","/CP049132_VMw.zip/metadata.zip/vendor-index.xml","/CP049132_VMw.zip/metadata.zip/vmware.xml","/CP049132_VMw.zip/metadata.zip/vibs/CP049132--7449206712739965198.xml","/CP049132_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049132_HPD9.2-7.0.0.15843807.xml"],"md5sum":"bc2c1a049d890b1013a9e4a075d27a1d","name":"CP049132.zip","release":"2021-08-26T10:21:34","revision":"0","sha1sum":"c1297cc0e4e44a952d6eec995c71c1b17f092ca5","size":"15MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049132","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"5e76fbf672b8432aa6436d748dacb463","version":"e5bd62e42eb14a1bba321303c671f55c"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB008000JWJRQおよび MB006000JWJRP ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:02:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for&nbsp;Windows (x64) -&nbsp;VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4922960","datemodified":"2021-07-24T10:58:15","file_list":["cp048487.xml","cpqsetup.exe","payload.json","setup.dll","spannmK4.rel"],"md5sum":"991c92dcbe92ab604b22ea64f3738527","name":"cp048487.exe","release":"2021-07-24T10:51:04","revision":"0","sha1sum":"3c1bcacf6a3ea79e3d39b29e33bfaee3fd992a58","size":"4MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"537734d235b44d80ac3623e8cb9c5d5b","version":"77e6a06222c541c1bff0465cb914ba65"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T08:29:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR216i-a","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-a_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR216i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7491291","datemodified":"2021-09-08T14:49:30","file_list":["HPE_MR216i-a_Gen10P_52.16.3-3913.ilo","HPE_MR216i-a_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"79f0438490fd4a7a514cd06b915d84ad","name":"HPE_MR216i-a_Gen10P_52.16.3-3913.fwpkg","release":"2021-09-08T14:44:59","revision":"0","sha1sum":"ec553af6dd5730f9c59c1163a3ce4c7fcf19bca0","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032c"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"2b01702f6be343c09f8208f8aab17afb","version":"e2bba27ce39e47e48f32cf2b65d78e55"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR216i-a Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR216i-a Gen10 Plusトライモードコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T14:05:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"032C1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following NVME drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85032G00</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>85031G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO version older than v2.30</li>\n</ul>\n"}],"files":[{"bytes":"7997320","datemodified":"2021-10-20T10:19:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/CP049349.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049349.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049349.scexe"],"md5sum":"27c787fec9b57a09241dda3b95a2073e","name":"firmware-hdd-805abb7e9c-85032G00-1.1.x86_64.rpm","release":"2021-10-20T10:05:17","revision":"0","sha1sum":"4daf6b6f523ae50d1898653ebc205f5a431e15b6","size":"7MB","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85032G00"}],"id":{"product":"f4d3c3f0b12d4c1da09c3d11188e06cf","version":"23c742e8e7cc4e2cbd8ad3e4b366a080"},"installation":{"command":"CP042967.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KXALB、VS003840KWXFQ、VS001920KWXFP、およびVS000960KWXFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"},{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T14:01:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This is a maintenance release that contains various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000JWXKH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000JWXKH Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3740792","datemodified":"2021-07-26T16:00:18","file_list":["cp049126.xml","cpqsetup.exe","payload.json","setup.dll","TAMG08scHPD9.REL"],"md5sum":"43dbb9db897d42ef1a51552f8dadbf88","name":"cp049126.exe","release":"2021-07-26T15:49:04","revision":"0","sha1sum":"95b50413eb655d5b4ebf684c9326d93652fbdff0","size":"3MB","target_guids":["4d2340a5-3042-3631-3030-304a57584b48"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"3b6a8a58b8154bb1b3a7b5b4416448b8","version":"eb14b7963f6b4a4fa0005a555b8a559e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000JWXKH","target_guid":"4d2340a5-3042-3631-3030-304a57584b48","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:44:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000JWXKH","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1166504","datemodified":"2022-01-25T07:33:05","file_list":["cp049618.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"fee9c048bc7365de51ea426190e2af59","name":"cp049618.exe","release":"2022-01-25T07:19:08","revision":"0","sha1sum":"48066d996c2f513b1da19ea48ced26811c2d97e5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"type_of_change":"1","version":"1.16.139.0"}],"id":{"product":"283d84a861d348648dca86da7b4218bd","version":"0b2787a39bb449afa4a006f659da957b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i40ea Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"i40ea.sys","sw_key_expectedpath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.00(C)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>VMware vSphere 6.7 OSのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点：</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"11528580","datemodified":"2018-09-25T14:26:34","file_list":["/CP037611.vmexe","/CP037611.vmfile","/CP037611.xml","/payload.json","/README.txt"],"md5sum":"c550122373e1a49be92c518768904b3d","name":"CP037611.zip","release":"2018-10-23T00:00:00","revision":"1","sha1sum":"0de2f549fd62b8bbf2572e0ba4d9919ec9a86b03","size":"10MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00","vib_list":[]}],"id":{"product":"c1bd991a7a664214ab29388b7b63a963","version":"f7c5708b9400487cbac2b9b942488a5f"},"installation":{"command":"CP037611.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 8.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-04T14:11:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4918187","datemodified":"2021-07-26T05:47:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/CP048214.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048214.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048214.scexe"],"md5sum":"f9882f8eb60915807a51431798e07f11","name":"firmware-hdd-aef2a690c9-HPG5-6.1.x86_64.rpm","release":"2021-07-26T05:34:07","revision":"0","sha1sum":"8d4ac1db96724169f14f9b8c75d7bce5e9a15fad","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"29456540dcc74eaf9f223e63cf50eff7","version":"886ac51dd32b4b329b0872d2280b5b3a"},"installation":{"command":"CP040776.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPP、およびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:23:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16176671","datemodified":"2021-08-27T18:52:01","file_list":["/CP049136_BUILD_1.data","/CP049136.vmexe","/CP049136.vmexe64","/CP049136.vmfile","/CP049136_VMw.zip","/CP049136.xml","/payload.json","/CP049136_VMw.zip/index.xml","/CP049136_VMw.zip/vendor-index.xml","/CP049136_VMw.zip/metadata.zip","/CP049136_VMw.zip/vib20/CP049136/HPE_bootbank_CP049136_HPD7.1-7.0.0.15843807.vib","/CP049136_VMw.zip/metadata.zip/vendor-index.xml","/CP049136_VMw.zip/metadata.zip/vmware.xml","/CP049136_VMw.zip/metadata.zip/vibs/CP049136--1021048504555796351.xml","/CP049136_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049136_HPD7.1-7.0.0.15843807.xml"],"md5sum":"cd7a1bc51a52ee610136dcaa39939d7c","name":"CP049136.zip","release":"2021-08-27T18:47:24","revision":"0","sha1sum":"e1bb406e0aa6b8298b2e57999d17c4331162e55b","size":"15MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP049136","version":"HPD7.1-7.0.0.15843807"}]}],"id":{"product":"486d4489346f4ec8a160ad4ef3c94f99","version":"5d8ec9a8c2dd4a6385901d63e1a41762"},"installation":{"command":"CP041673.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:57:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware fixes a condition that could cause the heads to land on the media in an emergency power off situation, and eliminates a command timeout issue. Some internal logging operations were refined at the same time.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11562273","datemodified":"2022-03-10T22:00:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/CP051201.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/U38_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051201.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051201.scexe"],"md5sum":"22fcab57d36b1ade097f81e8ae1cec75","name":"firmware-system-u38-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-10T21:53:43","revision":"0","sha1sum":"f041c7ae791bd9027940a5e867388771c1df3f38","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"7ebf7b3b32234babb113c6746f09f68e","version":"e96e836fbf0c4c29b8147e8565c1ab6a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:56:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6136728","datemodified":"2021-07-23T07:33:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/CP048131.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/HVLAeAaseFG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG1-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048131.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048131.scexe"],"md5sum":"0d9859ac95a9e5da7c2ca19a259f089d","name":"firmware-hdd-7f2a26e6d0-HPG1-5.1.x86_64.rpm","release":"2021-07-23T07:21:06","revision":"0","sha1sum":"3b899cdf08227bb5c172d44228c802a54c8e475f","size":"5MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"d33174a587ab4b3ea4d5e4e22de786d1","version":"69e5c7740ff0497287195eec9bc9a7b9"},"installation":{"command":"CP041521.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWKGRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:09:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5595948","datemodified":"2021-07-23T08:14:31","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/CP048092.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/HBCMSssseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048092.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048092.scexe"],"md5sum":"c7b0ea9c34697880536ac064cc4d7b93","name":"firmware-hdd-5dcf26fa42-HPD2-6.1.x86_64.rpm","release":"2021-07-23T08:01:16","revision":"0","sha1sum":"e5b62e18930bf54a67b06244386c34c44f17b964","size":"5MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"896ea0712e9c4853949ccb47860e6c63","version":"0d79eecee8e54d71a1b79af30953b7a8"},"installation":{"command":"CP040329.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:04:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4065320","datemodified":"2021-07-25T20:28:34","file_list":["cp048649.xml","cpqsetup.exe","payload.json","SCIMARRNESD6.rel","setup.dll"],"md5sum":"caff32c0adbac1851ac336023fb60b69","name":"cp048649.exe","release":"2021-07-25T20:21:11","revision":"0","sha1sum":"5fa2f673a3574115c543ded74789f2f125cabfb3","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"8e4da865e5b44ea38e4b650ce9a93715","version":"cb2403eaa693447a9cf1f95d9a8d0c70"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:34:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG3"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG3"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000GWWQH, MB002000GWWQF and MB001000GWWQE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;</strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17503636","datemodified":"2021-08-27T11:57:32","file_list":["/CP048430_BUILD_2.data","/CP048430.vmexe","/CP048430.vmexe64","/CP048430.vmfile","/CP048430_VMw.zip","/CP048430.xml","/payload.json","/CP048430_VMw.zip/index.xml","/CP048430_VMw.zip/vendor-index.xml","/CP048430_VMw.zip/metadata.zip","/CP048430_VMw.zip/vib20/CP048430/HPE_bootbank_CP048430_HPG3.2-7.0.0.15843807.vib","/CP048430_VMw.zip/metadata.zip/vendor-index.xml","/CP048430_VMw.zip/metadata.zip/vmware.xml","/CP048430_VMw.zip/metadata.zip/vibs/CP048430-384385079037484807.xml","/CP048430_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048430_HPG3.2-7.0.0.15843807.xml"],"md5sum":"24a00a51b0ce11cd55905a26809ce9a5","name":"CP048430.zip","release":"2021-08-27T11:52:14","revision":"0","sha1sum":"2ba8e5af35a49212f7ef81c50d62daef26254d42","size":"16MB","target_guids":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048430","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"df6ba3c2e569412ab3999b9575ddb1d8","version":"fa792b6f7b3a437ebcfc68e1bc6ed39f"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>T</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB004000GWWQH、MB002000GWWQF、およびMB001000GWWQEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWWQH","target_guid":"4d2340a5-3042-3430-3030-304757575148","type":"sata"},{"id":"MB002000GWWQF","target_guid":"4d2340a5-3042-3230-3030-304757575146","type":"sata"},{"id":"MB001000GWWQE","target_guid":"4d2340a5-3042-3130-3030-304757575145","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T08:34:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWWQE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWWQF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB004000GWWQH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6135077","datemodified":"2021-07-23T08:13:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/CP048103.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/HVLAnAsseFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048103.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048103.scexe"],"md5sum":"4147120f47ec4170154ae54885193007","name":"firmware-hdd-2c27a7a9a4-HPD2-2.1.x86_64.rpm","release":"2021-07-23T08:01:07","revision":"0","sha1sum":"8c7992103cadac6c2e751dfe45aaa05e72d34ced","size":"5MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"188f54d508794fafbb14f21866a0ffb5","version":"b54141db67c94dddad083c1db63e194a"},"installation":{"command":"CP041491.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -  MB004000JWKGU ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T16:43:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and&nbsp;MK001920GWUGK&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3137224","datemodified":"2021-07-25T18:52:57","file_list":["cp048638.xml","cpqsetup.exe","M5200SG3.rel","payload.json","setup.dll"],"md5sum":"858d913900f19c5c331840f21554631b","name":"cp048638.exe","release":"2021-07-25T18:46:04","revision":"0","sha1sum":"3ae62fdb4cac4db208510e309b8e24209971dd79","size":"2MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"75bc856a96a1425a954558bdb79908f8","version":"499e970ea43d4d28b6ec55dd87f80cd7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T16:51:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on SUSE Linux Enterprise Server 15 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1638456","datemodified":"2021-08-27T06:01:28","file_list":["./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/i386/lib/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/i386/lib/libbrcmemsdm.so","./opt/broadcom/sles15sp2/i386/lib/libbrcmhbaapi.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/sles15sp2/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/libbrcmdfc.so","./usr/lib/libbrcmdfc.so.12","./usr/lib/libbrcmdfc.so.12.0.1329","./usr/lib/libbrcmemsdm.so","./usr/lib/libbrcmhbaapi.so","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"b405baedc7a27f614d9903a4bdaa2078","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.sles15sp2.x86_64.rpm","release":"2021-08-27T05:56:48","revision":"0","sha1sum":"cc6157c8232be8bd490e7c1aeedfb338b8f46353","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"c901792d2373446f89ecbbbaab9a8f09","version":"e216363e25174bf489bc9f9dc4d7a9ad"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10+ controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2700773","datemodified":"2021-09-08T16:45:12","file_list":["./opt/hpe/storcli/storcli64","./usr/lib/.build-id","./usr/lib/.build-id/18","./usr/lib/.build-id/18/da821f3768420ff26e9e349668617a13970af6","./usr/share/smartupdate/storcli/component.xml"],"md5sum":"2c57b64890af2f0f4a9cd31e79f3ced8","name":"storcli-007.1616.0000.0000-1.x86_64.rpm","release":"2021-09-08T16:35:27","revision":"0","sha1sum":"6555cdaaea1a275d8aa764233c4b0b39ad1d6bb8","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"type_of_change":"0","version":"007.1616.0000.0000"}],"id":{"product":"1e5bf302dfcf48eb8cdaa03a5c140f4d","version":"57fb5af76eec40f1ba2819b423787130"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>STORCLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of STORCLI installed on the system, please use &quot;rpm -e storcli-&lt;version&gt;.noarch&quot; to remove it first.</li>\n\t<li>To install the StorCLI RPM, run the rpm -ivh &lt;StorCLI-x.xx-x.noarch.rpm&gt; command.</li>\n\t<li>To upgrade the StorCLI RPM, run the rpm -Uvh &lt;StorCLI-x.xx-x.noarch.rpm&gt; command</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n\t<li>The software resides in /opt/hpe/storcli and the executable name is storcli64.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"},{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-13T10:23:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This version of StorCLI supports maintaining, troubleshooting, and configuration functions for the MegaRAID&reg; Gen10+ controller products: MR416i-a,&nbsp;MR416i-p,&nbsp;MR216i-a,&nbsp;MR216i-p</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10Plus server</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"storcli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33586280","datemodified":"2022-02-08T02:45:12","file_list":["payload.json","U47_1.58_01_13_2022.signed.flash","U47_1.58_01_13_2022.xml"],"md5sum":"675ad0298615b7105f5f6b7debe3a03c","name":"U47_1.58_01_13_2022.fwpkg","release":"2022-02-08T02:41:11","revision":"0","sha1sum":"934883f4b7f65b4c048625dfed06c7d339efdf2b","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"a294766010e4496a9a5cf2711f22fa84","version":"b3ced05cdb704c58b59e5d4019272292"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-07T18:11:50","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JETKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45544b41","Version":"HPD8"},{"DeviceName":"EG0900JETKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45544b42","Version":"HPD8"},{"DeviceName":"EG1200JETKC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SED8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45544b43","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0600JETKA, EG0900JETKB and EG1200JETKC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0600JETKA,&nbsp;EG0900JETKB&nbsp;and&nbsp;EG1200JETKC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16005366","datemodified":"2021-08-30T05:29:09","file_list":["/CP048264_BUILD_2.data","/CP048264.vmexe","/CP048264.vmexe64","/CP048264.vmfile","/CP048264_VMw.zip","/CP048264.xml","/payload.json","/CP048264_VMw.zip/index.xml","/CP048264_VMw.zip/vendor-index.xml","/CP048264_VMw.zip/metadata.zip","/CP048264_VMw.zip/vib20/CP048264/HPE_bootbank_CP048264_HPD8.2-7.0.0.15843807.vib","/CP048264_VMw.zip/metadata.zip/vendor-index.xml","/CP048264_VMw.zip/metadata.zip/vmware.xml","/CP048264_VMw.zip/metadata.zip/vibs/CP048264--66723586510665876.xml","/CP048264_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048264_HPD8.2-7.0.0.15843807.xml"],"md5sum":"dfdaadd427878ddbed2480e56c92863a","name":"CP048264.zip","release":"2021-08-30T05:24:36","revision":"0","sha1sum":"810eacd21a019163e318038aa793f096d9f7b28d","size":"15MB","target_guids":["002340a5-4500-3047-3630-304a45544b41","002340a5-4500-3047-3930-304a45544b42","002340a5-4500-3147-3230-304a45544b43"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP048264","version":"HPD8.2-7.0.0.15843807"}]}],"id":{"product":"d5fee9f753d04f3ba9583fdfe0002842","version":"42c35874b46445528a6b19861c62437e"},"installation":{"command":"CP040504.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG0600JETKA, EG0900JETKB and EG1200JETKC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG0600JETKA、EG0900JETKB、およびEG1200JETKCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JETKC","target_guid":"002340a5-4500-3147-3230-304a45544b43","type":"sas"},{"id":"EG0600JETKA","target_guid":"002340a5-4500-3047-3630-304a45544b41","type":"sas"},{"id":"EG0900JETKB","target_guid":"002340a5-4500-3047-3930-304a45544b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T11:02:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JETKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JETKC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JETKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;219.0.17.0 and RoCE driver version&nbsp;219.0.4.0.</p>\n"}],"files":[{"bytes":"374700","datemodified":"2021-09-28T12:19:57","file_list":["/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip","/cp047899.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_219.0.29.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_219.0.13.0-1OEM.670.0.0.8169922.vib","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip/vibs/bnxtnet--5677814717666654054.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip/vibs/bnxtroce--8914065072407541918.xml","/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922-offline_bundle-18604373.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_219.0.235.0-1OEM.670.0.0.8169922.xml"],"md5sum":"13c43d1fee869d09216938091ace547b","name":"cp047899.zip","release":"2021-09-28T12:15:48","revision":"0","sha1sum":"c6322581d811c7feb44dd1decb9e1c15e7b909f8","size":"365KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"bnxtnet","version":"219.0.29.0-1OEM.670.0.0.8169922"},{"name":"bnxtroce","version":"219.0.13.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"8cec45e9870e4e5fad3d7d2b3b545e8d","version":"db37b1f183844ef0888ec5a344b8d387"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances that new query for Firmware health data.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtroce:219.0.13.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtnet:219.0.29.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE iLO Driver allows software to communicate with the iLO management controller. This driver is used by the Agentless Management Service, firmware flash components, and other utilities. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"22041","datemodified":"2021-04-12T20:22:09","file_list":["/cp047518.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/vendor-index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/vib20/ilo/HPE_bootbank_ilo_700.10.7.5.2-1OEM.700.1.0.15843807.vib","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vendor-index.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vmware.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/vibs/ilo--2313206460127334238.xml","/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807_17856914.zip/metadata.zip/bulletins/ilo-driver_700.10.7.5.2-1OEM.700.1.0.15843807.xml"],"md5sum":"e44a35ab20dbcbe3b8990b2a05d46201","name":"cp047518.zip","release":"2021-04-12T20:20:07","revision":"0","sha1sum":"2fd6961479ff8532f29d2641e1685cc45b121b47","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"ilo","version":"700.10.7.5.2-1OEM.700.1.0.15843807"}]}],"id":{"product":"6439c3485f63410da139047f5f5bc562","version":"9bf4101945d34091a6f025aa513e9bd4"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE iLO Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Supports ESXi 7.0 and ESXi 7.0 U1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload and when Quickboot is enabled.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ilo-driver:700.10.7.5.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"ilo:700.10.7.5.2-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package enables auto-nvme connectivity support on Linux Server for HPE Emulex Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、Linuxサーバーでのauto-nvme接続サポートをHPE Emulexホストバスアダプターに対して有効にします"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8720","datemodified":"2021-11-15T06:46:32","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"f382ec722082838e31cf95c868032169","name":"nvmefc-connect-12.8.264.0-1.rhel7u9.noarch.rpm","release":"2021-11-15T06:40:55","revision":"0","sha1sum":"0b61ce2833a7bc8959b4979ffccecc3f18aefce8","size":"8KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9cc0c84f"],"type_of_change":"0","version":"12.8.264.0"},{"bytes":"8720","datemodified":"2021-11-15T06:49:25","file_list":["./usr/lib/dracut/dracut.conf.d/70-nvmefc-autoconnect.conf","./usr/lib/systemd/system/nvmefc-boot-connections.service","./usr/lib/systemd/system/nvmefc-connect@.service","./usr/lib/udev/rules.d/70-nvmefc-autoconnect.rules","./usr/sbin/lpfc/nvmefc_boot_connections.sh","./usr/share/smartupdate/nvmefc-connect/component.xml"],"md5sum":"81dce5551d4a7cdad1a7043f5d7226b3","name":"nvmefc-connect-12.8.264.0-1.rhel7u8.noarch.rpm","release":"2021-11-15T06:40:55","revision":"0","sha1sum":"5ff13bff70986f7ea761f9de4dd1d57f421d27ff","size":"8KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9cc0c84f"],"type_of_change":"0","version":"12.8.264.0"}],"id":{"product":"edfc3fe1db664c19ac762129db3cbadb","version":"44ceb59ddddf435faba65173a8430432"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n\n<p>To upgrade the elx-nvmefc-connect RPM use the following command:</p>\n\n<p>&nbsp;# rpm -Uvh elx-nvmefc-connect-&lt;version&gt;.noarch.rpm</p>\n"},{"lang":"ja","x_late":"<p>elx-nvmefc-connect RPMをインストールするには、次のコマンドを使用します。</p>\n\n<p>   # rpm -ivh elx-nvmefc-connect-<version>.noarch.rpm</p>\n\n<p>elx-nvmefc-connect RPMをアップグレードするには、次のコマンドを使用します。</p>\n\n<p> # rpm -Uvh elx-nvmefc-connect-<version>.noarch.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NVMe Fibre Channel Enablement Kit for Emulex Host Bus Adapters for Linux  Server"},{"lang":"ja","x_late":"HPE NVMeファイバーチャネルイネーブルメントキットfor Emulexホストバスアダプター - Linuxサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.8.264.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.264.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"},{"name":"nvmefc-connect","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3553912","datemodified":"2021-07-25T16:51:56","file_list":["cp048623.xml","cpqsetup.exe","payload.json","SAVGNTG5.rel","setup.dll"],"md5sum":"625499ba8fd566c7e78713914d4108b8","name":"cp048623.exe","release":"2021-07-25T16:44:05","revision":"0","sha1sum":"60a06da60b71a0e0ef3b9c0def0464da75f26cda","size":"3MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5"}],"id":{"product":"4106b2f5d7c1411c95e94d52dff63df7","version":"d41d13114060474a9ee817bf0d9588b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000GFJTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000GFJTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:04:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19226869","datemodified":"2021-02-03T03:26:06","file_list":["/CP045902.vmexe","/CP045902.vmfile","/CP045902_VMw.zip","/CP045902.xml","/payload.json","/README.txt","/CP045902_VMw.zip/index.xml","/CP045902_VMw.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip","/CP045902_VMw.zip/vib20/CP045902/HPE_bootbank_CP045902_1.0.1-6.5.0.4240417.vib","/CP045902_VMw.zip/metadata.zip/vendor-index.xml","/CP045902_VMw.zip/metadata.zip/vmware.xml","/CP045902_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045902_1.0.1-6.5.0.4240417.xml","/CP045902_VMw.zip/metadata.zip/vibs/CP045902-3689128572757422720.xml"],"md5sum":"7ef2fa5fcdeda7baa7a781a13bc510cb","name":"CP045902.zip","release":"2021-02-03T03:32:05","revision":"0","sha1sum":"a312f7e5a269d8b8936daec7b2d85b25d06893b3","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.7","vib_list":[{"name":"CP045902","version":"1.0.1-6.5.0.4240417"}]}],"id":{"product":"7a662f7d75e94013936ff11b1e7b1553","version":"5249928f049242e2998a48ccc80bb585"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33808863","datemodified":"2022-02-07T08:16:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/CP050649.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/U50_1.58_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u50-1.58_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050649.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050649.scexe"],"md5sum":"f9915183330be32eaaf375b3d2200e5c","name":"firmware-system-u50-1.58_2022_01_13-1.1.x86_64.rpm","release":"2022-02-07T08:08:30","revision":"0","sha1sum":"12c0fc1bb834a6bc9584a9074a054d396b3e346e","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"d4e991bf139c45c8a6f5a9b30e1a9d04","version":"f605df2dc7f74304998e5f8568a4be86"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\nコマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-03T02:47:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"U50","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"978905","datemodified":"2021-03-08T20:16:34","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2iscsi","./lib/modules/4.12.14-195-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"6a3c58bf25de820d0d57cd829268fb3b","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"8b5de4adc1f362a2760a7c9eaddcad4810e483e2","size":"955KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"1050641","datemodified":"2021-03-08T20:22:21","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2iscsi","./lib/modules/5.3.18-22-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi_bl-kmp-default/component.xml"],"md5sum":"f7e0721ba79cc0efd1cce3dd9ea099b9","name":"be2iscsi_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:03:04","revision":"0","sha1sum":"9851f2e3917fa0b45efdf331c67a3cb7e2347bc9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6b47a9e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"86e4b3a553494874939d56f97075cb67","version":"cf72dc2669f74c42816776cc86d25202"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for&nbsp;VMware ESXi -&nbsp;&nbsp;VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN Drives.<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85032G00</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;85031G00</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li><strong>&nbsp;</strong>Requires iLO5 v2.30 or later, SUM will not detect SSD as applicable for Firmware update for deployment with iLO5 version older than v2.30</li>\n</ul>\n"}],"files":[{"bytes":"22366624","datemodified":"2021-10-20T11:10:54","file_list":["/CP049351_BUILD_3.data","/CP049351.vmexe","/CP049351.vmexe64","/CP049351.vmfile","/CP049351_VMw.zip","/CP049351.xml","/payload.json","/CP049351_VMw.zip/index.xml","/CP049351_VMw.zip/vendor-index.xml","/CP049351_VMw.zip/metadata.zip","/CP049351_VMw.zip/vib20/CP049351/HPE_bootbank_CP049351_85032G00.3-7.0.0.15843807.vib","/CP049351_VMw.zip/metadata.zip/vendor-index.xml","/CP049351_VMw.zip/metadata.zip/vmware.xml","/CP049351_VMw.zip/metadata.zip/vibs/CP049351--5198069091505085516.xml","/CP049351_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049351_85032G00.3-7.0.0.15843807.xml"],"md5sum":"1f336057672d1e6870ffae16091dc8f6","name":"CP049351.zip","release":"2021-10-20T11:04:28","revision":"0","sha1sum":"74fb4e37fa12a549c5c4651bde26d8e67f9aa3b1","size":"21MB","target_guids":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"type_of_change":"1","version":"85032G00","vib_list":[{"name":"CP049351","version":"85032G00.3-7.0.0.15843807"}]}],"id":{"product":"fc28c0050f9d4a8a94e83f990b230b39","version":"a699df6b93d94c07b8a629159872788d"},"installation":{"command":"CP042969.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - VS000480KXALB、VS000960KWXFN、VS001920KWXFP、およびVS003840KWXFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VS003840KWXFQ","target_guid":"562340a5-3053-3330-3834-304b57584651","type":"nvme"},{"id":"VS001920KWXFP","target_guid":"562340a5-3053-3130-3932-304b57584650","type":"nvme"},{"id":"VS000960KWXFN","target_guid":"562340a5-3053-3030-3936-304b5758464e","type":"nvme"},{"id":"VS000480KXALB","target_guid":"562340a5-3053-3030-3438-304b58414c42","type":"nvme"},{"dev":"2241","subdev":"02F6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1b4b-2241159002f6","type":"pci","ven":"1B4B"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-25T14:28:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This is a maintenance release that contains various drive reliability enhancements and code fixes accumulated since the last initial release, as well as a change to disable MCTP over PCIe VDM function to satisfy certain HPE platform environments.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Implements FW-based VPD.</li>\n\t<li>ARP setting is changed from &ldquo;Capable &amp; Discoverable&rdquo; to &ldquo;Fixed &amp; Discoverable&rdquo;.</li>\n\t<li>A minor tweak to the Foreground Media Scan (FMS) algorithm to ensure critical variables are initialized properly.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"VS003840KWXFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWXFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS001920KWXFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KXALB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3000856","datemodified":"2021-07-26T18:36:44","file_list":["cp049138.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXn0HPD7.REL"],"md5sum":"b5cfed5a3fbe3d6d348758141b0311f6","name":"cp049138.exe","release":"2021-07-26T18:28:05","revision":"0","sha1sum":"0426ee61e3eb0e839d4afd2dfa1d2b9ef42c0b10","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"0a96bc740aee4364b774edfa452ca9a4","version":"db2ca8b92ea7413b9919b1a5dd582fac"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:06:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13360192","datemodified":"2022-03-08T10:06:23","file_list":["cp051120.xml","cpqsetup.exe","I41_2.62_03_08_2022.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"f05a1fe020803b7efb03aa48f8170f29","name":"cp051120.exe","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"84eede10ef0950594be07d45189f6427f92dc6a2","size":"12MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"51d4f5b1652542c6b4d9e256967fc72b","version":"ad07df9f484247758ff1640d7b3489bc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p> </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant BL460c Gen10 (I41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant BL460c Gen10 (I41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:35:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、NCSI、iSCSI、FCoEおよびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"4571024","datemodified":"2021-08-12T09:36:21","file_list":["BNICOFUT.pdf","cp047538.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.18.82.bin","ja/","ja/BNICOFUT_JA.pdf","LibQLGC_HpFwUpg.dll","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"7803f69a89eab306b2cdd6007983708c","name":"cp047538.exe","release":"2021-08-12T09:27:07","revision":"0","sha1sum":"588c1debbf7f2e6d569f257482e0867d1de98c98","size":"4MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.0.5.3"}],"id":{"product":"7ba136be4b834a5699f5c5fff754d07b","version":"9620e2bf90f84816a023fc2830fee22e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR>\n<P>［インストール］ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1025344","datemodified":"2021-11-02T08:49:28","file_list":["cp047049.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"md5sum":"531990d77d71bfa1e3cdfd12ca757ae6","name":"cp047049.exe","release":"2021-11-02T08:35:06","revision":"0","sha1sum":"3824445c505edd678a366551aa16fe82ed90f985","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"type_of_change":"0","version":"4.1.239.0"}],"id":{"product":"7a38c76de8ff4383970907d2998b1740","version":"3d2b37a4da2c4335ada5edac9988ed3f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated .cat file.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXN.dll and ixnmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ixn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SPSGen10Plus_04.04.04.062.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.062"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8409281","datemodified":"2022-01-26T08:39:08","file_list":["payload.json","SPSGen10Plus_04.04.04.062.signed.bin","SPSGen10Plus_04.04.04.062.xml"],"md5sum":"b0d993d05895cd1db439ff871ec5d2fd","name":"SPSGen10Plus_04.04.04.062.fwpkg","release":"2022-01-26T08:35:48","revision":"0","sha1sum":"af949ef52aea6e04a8e0a5169491ccf58aec1aed","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-87800a000101"],"type_of_change":"0","version":"04.04.04.062"}],"id":{"product":"6e357a862ebf4f379b5f531a7eb46680","version":"daad34959a0847ab93eda88954b9eb45"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T08:32:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>Added support for Intel Optane Persistent Memory.</p><p><strong>Known Issues:</strong></p>None","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version of the System ROM contains updates aligned with the INTEL Whitley BKC WW52.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"SPS_Gen10Plus","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel over Ethernet array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"923191","datemodified":"2021-08-27T06:03:32","file_list":["./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12","./opt/broadcom/rhel8/x86_64/lib64/libbrcmdfc.so.12.0.1329","./opt/broadcom/rhel8/x86_64/lib64/libbrcmemsdm.so","./opt/broadcom/rhel8/x86_64/lib64/libbrcmhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/75","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66","./usr/lib/.build-id/75/7c1bf6797cbd66b05c35bb64a5d5603f67ad66.1","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b","./usr/lib/.build-id/7c/1b0a41fc41e4bb166f002b7632fd98e45d938b.1","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8","./usr/lib/.build-id/b1/3574b27c2297ef7c922a0558dc0044a36035a8.1","./usr/lib64/libbrcmdfc.so","./usr/lib64/libbrcmdfc.so.12","./usr/lib64/libbrcmdfc.so.12.0.1329","./usr/lib64/libbrcmemsdm.so","./usr/lib64/libbrcmhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Broadcom-Enablement-Kit/component.xml"],"md5sum":"d3b00615ab7c5052beb4b151f1f352dd","name":"HPE-CNA-FC-Broadcom-Enablement-Kit-12.0.1339.0-1.rhel8.x86_64.rpm","release":"2021-08-27T05:56:11","revision":"0","sha1sum":"82081a0461769e1fcc026c8bb816ef4eda150dcc","size":"901KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece07e7061"],"type_of_change":"1","version":"12.0.1339.0"}],"id":{"product":"0789ba677e9748e99f7b62253abbd63d","version":"e4c941bbf5794a1e83c7b7dd5ea11fb7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>There has been a change to the enablement kits in this release.&nbsp; They are now vendor specific kits.&nbsp;&nbsp; It is recommended that you uninstall any previous kits prior to installation of this component.<br />\n<br />\nTo uninstall the hp-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -e hp-fc-enablement-&lt;version&gt;.noarch.rpm<br />\n<br />\nTo install the hp-CNA-fc-enablement RPM use the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm -ivh HP-CNA-FC-Broadcom-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm<br />\n<br />\nThis version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:<br />\n&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a><br />\n&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex(BRCM) Fibre Channel Over Ethernet Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version: 12.0.1339.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Broadcom-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWFWN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a5746574e","Version":"HPD5"},{"DeviceName":"MO000800JWFWP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57465750","Version":"HPD5"},{"DeviceName":"MO001600JWFWQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57465751","Version":"HPD5"},{"DeviceName":"MO003200JWFWR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57465752","Version":"HPD5"},{"DeviceName":"MO000960JWFWT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a57465754","Version":"HPD5"},{"DeviceName":"MO001920JWFWU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57465755","Version":"HPD5"},{"DeviceName":"MO003840JWFWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM4VVEHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a57465756","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4794667","datemodified":"2021-07-23T07:59:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/CP048182.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/TAPM4VVEHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b8a60fbe9a-HPD5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048182.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048182.scexe"],"md5sum":"b5bd338396cdbb8e20f7710f1bc0de24","name":"firmware-hdd-b8a60fbe9a-HPD5-5.1.x86_64.rpm","release":"2021-07-23T07:46:08","revision":"0","sha1sum":"eb2d52c9cd1e887f75fd7410c7fec3cb28a90c01","size":"4MB","target_guids":["4d2340a5-304f-3030-3430-304a5746574e","4d2340a5-304f-3030-3830-304a57465750","4d2340a5-304f-3130-3630-304a57465751","4d2340a5-304f-3330-3230-304a57465752","4d2340a5-304f-3030-3936-304a57465754","4d2340a5-304f-3130-3932-304a57465755","4d2340a5-304f-3330-3834-304a57465756"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0621549b347544c1869a7fcad2fb7ecf","version":"82264eeba1a94c428c28f18f331f862a"},"installation":{"command":"CP041423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO000400JWFWN, MO000800JWFWP, MO001600JWFWQ, MO003200JWFWR, MO000960JWFWT, MO001920JWFWU and MO003840JWFWV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64)-MO000400JWFWN、MO000800JWFWP、MO001600JWFWQ、MO003200JWFWR、MO000960JWFWT、MO001920JWFWUおよびMO003840JWFWVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200JWFWR","target_guid":"4d2340a5-304f-3330-3230-304a57465752","type":"sas"},{"id":"MO001920JWFWU","target_guid":"4d2340a5-304f-3130-3932-304a57465755","type":"sas"},{"id":"MO001600JWFWQ","target_guid":"4d2340a5-304f-3130-3630-304a57465751","type":"sas"},{"id":"MO000960JWFWT","target_guid":"4d2340a5-304f-3030-3936-304a57465754","type":"sas"},{"id":"MO000800JWFWP","target_guid":"4d2340a5-304f-3030-3830-304a57465750","type":"sas"},{"id":"MO000400JWFWN","target_guid":"4d2340a5-304f-3030-3430-304a5746574e","type":"sas"},{"id":"MO003840JWFWV","target_guid":"4d2340a5-304f-3330-3834-304a57465756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:44:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003840JWFWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWFWR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWFWN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWFWU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWFWQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JWFWT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWFWP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK&nbsp;and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong> None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"16599527","datemodified":"2021-08-27T12:43:23","file_list":["/CP048439_BUILD_3.data","/CP048439.vmexe","/CP048439.vmexe64","/CP048439.vmfile","/CP048439_VMw.zip","/CP048439.xml","/payload.json","/CP048439_VMw.zip/index.xml","/CP048439_VMw.zip/vendor-index.xml","/CP048439_VMw.zip/metadata.zip","/CP048439_VMw.zip/vib20/CP048439/HPE_bootbank_CP048439_HPD9.3-7.0.0.15843807.vib","/CP048439_VMw.zip/metadata.zip/vendor-index.xml","/CP048439_VMw.zip/metadata.zip/vmware.xml","/CP048439_VMw.zip/metadata.zip/vibs/CP048439-7103474675442070464.xml","/CP048439_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048439_HPD9.3-7.0.0.15843807.xml"],"md5sum":"fd1af67cc18ef29e7d89ee36d2b5dcac","name":"CP048439.zip","release":"2021-08-27T12:38:09","revision":"0","sha1sum":"b56c2e0497909ee4c8cf2a88ff9235c35ed5f165","size":"15MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048439","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"4e3d7926d2c648d2b99239bbce77f310","version":"6ed633d59ccd483ab1d82d0ecea8b2ff"},"installation":{"command":"CP042779.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO0400JFFCF、MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:39:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) devices on Windows x86_64 platform. See the supported devices list in the Supported devices section."},{"lang":"ja","x_late":"このパッケージは、Windows x86_64プラットフォーム上でHPE VPI (EthernetおよびInfinibandモードで動作)デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。 [サポートされるデバイス]セクションでサポートされるデバイスのリストを参照してください。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15785992","datemodified":"2020-11-12T07:53:23","file_list":["cp045905.xml","cpqsetup.exe","fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"feae578e4cc50a0ec032360edf98ab4b","name":"cp045905.exe","release":"2020-11-12T07:50:04","revision":"0","sha1sum":"11e9198d1258a0e94f559129217571e6c5919c4d","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.0.12"}],"id":{"product":"637d540b39214addb4d18ef0c3a8cbbf","version":"34bf979025e44dc3851a5dd91737e087"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on Windows x86_64 platform"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (Windows x64) for HPE Mellanox VPI (EthernetおよびInfinibandモード)デバイス - Windows x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component installs a Registry change to fix a fatal Non-Maskable Interrupt (NMI) when ejecting an NVMe drive."},{"lang":"ja","x_late":"このコンポーネントは、NVMeドライブをイジェクトする際の致命的なマスク不可割り込み (NMI) を修正するためにレジストリの変更をインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"615712","datemodified":"2021-07-01T15:17:55","file_list":["cp047948.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"md5sum":"d6b0b71ed7f2f9dbb67b53ce1af8f7bf","name":"cp047948.exe","release":"2021-07-01T15:16:05","revision":"0","sha1sum":"f826b5d2fac92f0e7520bc7bf6f5a0598efe7fbb","size":"601KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"type_of_change":"0","version":"1.1.0.0"}],"id":{"product":"130da7feaa1d444b8b70a759892883b1","version":"3f4a825bbd79445b929367eed663022b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_devices":[{"dev":"2020","subdev":"00EA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-2020159000ea","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-06-17T01:54:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Add support for Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Removed support for Windows Server 2012 R2</li>\n\t<li>Added support for Windows Server 2022</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"nvmeejectfix5.dll","sw_key_expectedpath":"%ProgramFiles%\\nvmefix"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11360104","datemodified":"2022-03-08T13:16:42","file_list":["cp051284.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_2.62_03_08_2022.signed.flash"],"md5sum":"9cce2ea8040dc75789851f1628625b47","name":"cp051284.exe","release":"2022-03-08T13:15:01","revision":"0","sha1sum":"5023c9abcc9ea408e30d1b0da949907ef971eec7","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"0e95d953f6c341e2ab45544cad6adaa1","version":"8903460d162843b587ec82a1e8892975"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML110 Gen10 (U33)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:33:21","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11414888","datemodified":"2022-03-10T21:57:07","file_list":["cp051196.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_2.62_03_08_2022.signed.flash"],"md5sum":"10772651e60151a4de76e4af5ef3732e","name":"cp051196.exe","release":"2022-03-10T21:55:47","revision":"0","sha1sum":"ed73bb4ef777529276a219b13f8b2559975af150","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"1bc921f76f2d48759522424a4aff4914","version":"a28d3a714b09401ea0ba4cb1323209df"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:12:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE Blade QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7上で動作するHPE Blade QLogic NX2 10/20 GbEマルチファンクションアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n\t<li>qfle3, version 1.1.17.0</li>\n</ul>\n"}],"files":[{"bytes":"1400657","datemodified":"2021-08-12T04:38:32","file_list":["/cp047629.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.17.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.59.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3f--2870239878310587039.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qfle3--5362795065017542531.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/vibs/qcnic--558619672783143317.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922-offline_bundle-18173562.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.143.0-1OEM.670.0.0.8169922.xml"],"md5sum":"df5a4e7646c5bacecb41c3d50cb0a5cc","name":"cp047629.zip","release":"2021-08-12T04:35:13","revision":"0","sha1sum":"5d76d4609869a2f51713f4816a8996a6afeea3eb","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"qfle3f","version":"1.1.25.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3","version":"1.1.17.0-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.59.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"86ed65a9ad3d4de69d4874b14dbe2a9a","version":"c520825cd81e46a08a99ad471673fc5e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vShere 6.7 U3.<br />\nThis product has improved handling of complex flooding and race condition issues.</p>\n","latest_fixes_x_late":"<p>This product addresses a PSOD involving an encapsulated header.<br />\nThis product addresses a PSOD seen during traffic scheduling.<br />\nThis product corrects an incorrect MTU value displayed by the ESXCLI tool.<br />\nThis product addresses a PSOD issue seen during Storage vMotion operation.<br />\nThis product addresses PSODs seen during discovery timeout, transmit scheduling, and LUN reset scenarios.<br />\nThis product addresses a PSOD seen on systems operating in a complicated VLAN environment.<br />\nThis product addresses a PSOD seen during critical packet drop scenarios.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances PLOGI for the HPE XP7 Storage Array.</p>\n","curr_fixes_x_late":"<p>This product addresses a PSOD seen while collecting data dump.<br />\nThis product addessses a PSOD seen during uplink reset with failure conditions.<br />\nThis product addresses a PSOD seen during device state changes without IDLE state.<br />\nThis product addresses a PSOD seen during scheduling fabic login.<br />\nThis product addresses a PSOD issue to enhance immediately flush in work queue and unload/quiesce mechanisms.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"qcnic:1.0.59.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.17.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB&nbsp;and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2877056","datemodified":"2021-07-25T12:36:48","file_list":["4IFDHPK4.rel","cp048428.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"31834d489466daadeab1b148d9101615","name":"cp048428.exe","release":"2021-07-25T12:29:14","revision":"0","sha1sum":"36948fb561e9728d3d5d74e1494d0ee114bd59a0","size":"2MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"8f00f37b744a48c992007d0537ca5fe1","version":"1709552d124d408fa390ababd0a7671f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T07:42:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000GFECR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304746454352","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB8000GFECR Drives "},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB8000GFECRドライブ "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp; MB8000GFECR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG5<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5402840","datemodified":"2021-07-23T07:49:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/CP048174.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/SMKRPTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6d922fc9a8-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048174.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048174.scexe"],"md5sum":"bda5e8191f929ac1bbc9224a360f612e","name":"firmware-hdd-6d922fc9a8-HPG6-6.1.x86_64.rpm","release":"2021-07-23T07:34:09","revision":"0","sha1sum":"7224e89fa244f5b1ba32a69379caf6b59047bf81","size":"5MB","target_guids":["002340a5-4d00-3842-3030-304746454352"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"d9c3a00a773f42a180ec8a2979413243","version":"d33f1f14f45f46718b152e04efb24b35"},"installation":{"command":"CP040293.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB8000GFECR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB8000GFECRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB8000GFECR","target_guid":"002340a5-4d00-3842-3030-304746454352","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:05:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GFECR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.7上で動作するHPE Blade Intel ixgbenアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.12.0.</p>\n"}],"files":[{"bytes":"198739","datemodified":"2021-08-12T03:50:26","file_list":["/cp045170.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.12.0-1OEM.670.0.0.8169922.vib","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/vibs/ixgben--163231294919778048.xml","/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922-offline_bundle-17890246.zip/metadata.zip/bulletins/Intel-ixgben_1.9.12.0-1OEM.670.0.0.8169922.xml"],"md5sum":"ec35a5ec9a25ac5d214645e17053659a","name":"cp045170.zip","release":"2021-08-12T03:47:06","revision":"0","sha1sum":"58f99d45f79ceee2ab65959363a8d6c2fb6ed7c8","size":"194KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"ixgben","version":"1.9.12.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"64cacd5223744f8db526479e2a86e773","version":"fefba4caa74845e79272b33c23480160"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbenドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":"<p>This product corrects a&nbsp;recursion termination condition so that recursion&nbsp;correctly ends in the case of&nbsp; PCIe link down.</p>\n\n<p>This product addresses an issue where the ixgben driver has high CPU overhead&nbsp;when an SFP+ module is absent.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 6.7 U3.</p>\n","curr_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.<br />\nThis product addresses issues with hardware VLAN offloading.<br />\nThis product addresses a TX hang during bi-directional traffic.<br />\nThis product addesses issues with NetQ RSS and VMDQ scenarios.<br />\nThis product addesses issues with MTU settings when SRIOV is enabled in DPDK environment<br />\nThis product addessses issues with several VF scenarios without PF interface.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.9.12.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP FlexFabric 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1933","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C22FA","Version":"7.18.82"},{"DeviceName":"HP FlexFabric 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1917","Version":"7.18.82"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A2103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 534M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1933","Version":"7.18.82"},{"DeviceName":"HP NPAR 10Gb 2-port 536FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C22FA","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1916","Version":"7.18.82"},{"DeviceName":"HP NPAR 20Gb 2-port 630M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.18.82.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16A4103C1917","Version":"7.18.82"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade QLogic NX2 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.18.82 with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP FlexFabric 10Gb 2-port 534M Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 536FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630FLB Adapter<br />\n\t\t\tHP FlexFabric 20Gb 2-port 630M Adapter</td>\n\t\t\t<td>7.16.03</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.0</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"22944364","datemodified":"2021-08-11T04:12:30","file_list":["/CP047647_BUILD_8.data","/CP047647.txt","/CP047647.vmexe","/CP047647.vmexe64","/CP047647.vmfile","/CP047647_VMw.zip","/CP047647.xml","/payload.json","/CP047647_VMw.zip/index.xml","/CP047647_VMw.zip/vendor-index.xml","/CP047647_VMw.zip/metadata.zip","/CP047647_VMw.zip/vib20/CP047647/HPE_bootbank_CP047647_1.5.2.8-7.0.0.15843807.vib","/CP047647_VMw.zip/metadata.zip/vendor-index.xml","/CP047647_VMw.zip/metadata.zip/vmware.xml","/CP047647_VMw.zip/metadata.zip/vibs/CP047647-1212703154968216485.xml","/CP047647_VMw.zip/metadata.zip/bulletins/Smart-Component-CP047647_1.5.2.8-7.0.0.15843807.xml"],"md5sum":"f3a7e08b27a8a628ab3c8dcb556d4e06","name":"CP047647.zip","release":"2021-08-11T04:08:22","revision":"0","sha1sum":"6d852670363a070636bb304d540ff95ea4161559","size":"21MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C1933","a6b1a447-382a-5a4f-14E4-16A2103C22FA","a6b1a447-382a-5a4f-14E4-16A2103C1917","a6b1a447-382a-5a4f-14E4-16A2103C1916","a6b1a447-382a-5a4f-14E4-16AE103C1933","a6b1a447-382a-5a4f-14E4-16A4103C22FA","a6b1a447-382a-5a4f-14E4-16A4103C1916","a6b1a447-382a-5a4f-14E4-16A4103C1917"],"type_of_change":"0","version":"1.5.2","vib_list":[{"name":"CP047647","version":"1.5.2.8-7.0.0.15843807"}]}],"id":{"product":"807963ddd98b4f45bbbe57b7d0cec0f8","version":"69f150005dd44d75bc753beb688e7ebb"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.6 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 7.7 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec63a13bba","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 8 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 12 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.14.63-1","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver for SUSE Linux Enterprise Server 15.1 version 7.14.63-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.650.0.0.4598673","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.650.0.0.4598673 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.0.87.0-1OEM.670.0.0.8169922","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.0.87.0-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.4.12.0-1OEM.700.1.0.15843807","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 1.4.12.0-1OEM.700.1.0.15843807 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.0.121.0-1OEM.700.1.0.15525992","description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.121.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade QLogic NX2オンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","latest_fixes_x_late":"<p>This product addresses an issue where powering on the system with any I/O virtualization functionality (NPAR, SR-IOV, etc) enabled results in an Uncorrectable Machine Check Exception (UMCE).<br />\nThis product addresses an issue where the WOL option is displayed on the Human Interface Infrastructure (HII) menu for 534M and 630M mezzanine devices, even though WOL is not supported on those devices.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 U3.</p>\n","curr_fixes_x_late":"<p>This product addresses an issue where the Maximum Transmission Unit (MTU) value of iSCSI function port is displayed as 0 bytes in AHS log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_NX2_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000300JWFVB&nbsp;Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3037848","datemodified":"2021-07-24T08:40:29","file_list":["cp048433.xml","cpqsetup.exe","payload.json","setup.dll","T14SErD3.REL"],"md5sum":"7e43eb95e7b155c1a87bb1245e098103","name":"cp048433.exe","release":"2021-07-24T08:32:04","revision":"0","sha1sum":"18284972895eee16ddb3024a0a0f1a497f3cd339","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"211fcef09ace432ba1e1c0cdad640eeb","version":"9f12f8888f2445babdd0b58c6d4b7fbc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWFVB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:44:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します：VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK&nbsp;and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5039895","datemodified":"2021-07-23T08:49:21","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/CP048187.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/M5100SGG.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3db7640485-HPGG-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048187.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048187.scexe"],"md5sum":"afc00e4a6dc17f94cca8080201086110","name":"firmware-hdd-3db7640485-HPGG-2.1.x86_64.rpm","release":"2021-07-23T08:37:10","revision":"0","sha1sum":"070b038a4585a8cd5ad69c1cbe6330d0bca485f4","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"8c0c47d5bf1446e88cb749de3c7fd2d0","version":"3a6cdd7eff9c4910858d764fbee5da8e"},"installation":{"command":"CP041319.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子のついていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T08:07:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3027400","datemodified":"2021-07-25T14:04:14","file_list":["cp048589.xml","cpqsetup.exe","payload.json","setup.dll","TTMRNSD4.REL"],"md5sum":"5ec3f3d59dfbea3618961c68c0e356c2","name":"cp048589.exe","release":"2021-07-25T13:57:04","revision":"0","sha1sum":"ef97d07b63088a88a38af916e4d0f6b628ade467","size":"2MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"96868d9680c84d50b81011a5d4811094","version":"d1d24df06b6a4d60ae84889e3f6d1cca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:28:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom NetXtreme-E NIC 的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom NetXtreme-E NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom NetXtreme-E Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"321384","datemodified":"2021-10-01T17:58:01","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/bnxt_en.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"md5sum":"f8c69ddac463619b68a2f3ad8580d31c","name":"bnxt_en-kmp-default-1.10.2_k4.12.14_120-219.0.55.0.sles12sp5.x86_64.rpm","release":"2021-10-01T17:44:02","revision":"0","sha1sum":"00dedfc1911f810ca8baa766b26e6a794ec044e3","size":"313KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"type_of_change":"0","version":"1.10.2-219.0.55.0"}],"id":{"product":"4449ff05e7054e05a09904ed0fed74a8","version":"3b047262bd994274a9fc86c69d65250d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>インストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom NetXtreme-E 驅動程式"},{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom NetXtreme-E 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Broadcom NetXtreme-E驱动程序"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</p>\n","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n\t<li>This product addresses an issue where Virtual Functions (VFs) cannot be configured while the Physical Function (PF) interface is administratively down.</li>\n\t<li>This product addresses an issue where system crash when driver unloads while firmware reset is in progress.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxt_en-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3およびMZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;EPK75H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>提供名：</strong><br />\n      オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ<br />\n <br />\n<strong>リリースバージョンおよび/または日付:</strong><br />\n      EPK75H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>最新の推奨またはクリティカルバージョン：</strong><br />\n      EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>前のファームウェアバージョン：</strong><br />\n      EPK74H3Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ファームウェアの関連性:<br />\n      </strong>なし  </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>改善点/新しい機能：</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">      なし</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>修正された問題：</strong></p>\n\n<ul>\n\t<li>アイドル電源モードでの誤ったUECCの問題を修正しました。</li>\n\t<li>古いファームウェアダウンロードブロッキング（EPK70H3Q〜EPK74H3Q）。</li>\n\t<li>ファームウェアは、各レーンのTXデータアライメントのオプションから変更されます。</li>\n\t<li>PCIe構成の読み取り操作時に、TLP完了後に割り込みをクリアするようにファームウェアが変更されました。</li>\n\t<li>詳しくは、HPE Customer Bulletin: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a>を参照してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>既知の問題点:<br />\n     </strong>なし</p>\n"}],"files":[{"bytes":"25278144","datemodified":"2021-08-27T07:37:28","file_list":["/CP048458_BUILD_3.data","/CP048458.vmexe","/CP048458.vmexe64","/CP048458.vmfile","/CP048458_VMw.zip","/CP048458.xml","/payload.json","/CP048458_VMw.zip/index.xml","/CP048458_VMw.zip/vendor-index.xml","/CP048458_VMw.zip/metadata.zip","/CP048458_VMw.zip/vib20/CP048458/HPE_bootbank_CP048458_EPK75H3Q.3-7.0.0.15843807.vib","/CP048458_VMw.zip/metadata.zip/vendor-index.xml","/CP048458_VMw.zip/metadata.zip/vmware.xml","/CP048458_VMw.zip/metadata.zip/vibs/CP048458--4454703523534727790.xml","/CP048458_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048458_EPK75H3Q.3-7.0.0.15843807.xml"],"md5sum":"0fa828aea7fc0cfdc89f974841aee5b6","name":"CP048458.zip","release":"2021-08-27T07:32:01","revision":"0","sha1sum":"031c0764f59a10ed655bbc83dac4c816d3514340","size":"24MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q","vib_list":[{"name":"CP048458","version":"EPK75H3Q.3-7.0.0.15843807"}]}],"id":{"product":"a1d749637b0b455e9a43d66fc6eed023","version":"c9c0061608f647d8b69e5c9c92a83833"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMeSSDフラッシュコンポーネントfor VMwareESXi - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"},{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T09:35:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050806.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2437213","datemodified":"2022-01-26T05:06:59","file_list":["./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/CP050808.xml","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/cp050806.compsig","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/cp050806.zip","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.039-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050808.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050808.scexe"],"md5sum":"14c148dea6998ad1ef7a641bc5a038a9","name":"firmware-ml30gen10plus_me-06.00.03.039-1.1.x86_64.rpm","release":"2022-01-26T05:02:09","revision":"0","sha1sum":"cb2791e16829d6f11eaccf10f5dfe9463977cff6","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"3eab1bf1c35b40e5b35b9f8cbcf441cd","version":"ddc044db3d244aaaadc311be6c968b44"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>Verify the RPM signature using the following steps:</strong></p>\n\n<p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p>\n\n<p>Import the public key while logged in as root by running the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>Verify the RPM:</strong></p>\n\n<p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p>\n\n<p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p>\n\n<p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p>\n\n<p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p>\n\n<p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-20T08:24:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33604295","datemodified":"2022-03-08T10:06:24","file_list":["payload.json","U30_2.62_03_08_2022.signed.flash","U30_2.62_03_08_2022.xml"],"md5sum":"5f3a175a3310c58538ab5cba93ba0247","name":"U30_2.62_03_08_2022.fwpkg","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"01df21e182c7626b19670c21bab1619eb38ba6b5","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"ab0976902eae4e0c8757219b825c91f8","version":"17d007e3280142e19f39cfaafa86bc31"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL380 Gen10(U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:35:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11616840","datemodified":"2022-03-08T12:52:30","file_list":["cp051304.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_2.62_03_08_2022.signed.flash"],"md5sum":"0bfce9ab27323e5bd4ed8ba95404af8d","name":"cp051304.exe","release":"2022-03-08T12:50:19","revision":"0","sha1sum":"2d64e8da8ccad97c758d3160b15b0cad17e456de","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"c94eb717d55e4213952a8c5723962404","version":"91875b96de0843958f6eadd7f278aa6b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント  for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T10:40:19","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter "},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 1ポートMCX653105A-HDAT QSFP56 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter&nbsp;(P23664-B21)</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000451</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1ポートMCX653105A-HDAT QSFP56 x16アダプター（P23664-B21）</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000451</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"5951837","datemodified":"2021-12-07T09:40:46","file_list":["20_32_1010-MCX653105A-HDA_HPE_Ax.pldm.signed","20_32_1010-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"dbd7b0adf45cd926063a5776fb95b854","name":"20_32_1010-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:37:23","revision":"0","sha1sum":"08326f039373c5064f8c114e49ba98bcf7121971","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"da435657efe64ff1a664870254b46a1c","version":"5904af33ad75430da16cb17e0ed6c24d"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the FWPKG supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported FWPKG file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Management Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>FWPKGでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているFWPKGファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter "},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 1ポートMCX653105A-HDAT QSFP56 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG） "}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1577216","datemodified":"2022-02-10T03:06:22","file_list":["cp049269.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"71b6b1c04e6bed7909fb09e18c0fbb42","name":"cp049269.exe","release":"2022-02-10T02:52:04","revision":"0","sha1sum":"542af0fb6e05a5656d8fb32392939cd45006a8ff","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"type_of_change":"1","version":"1.10.51.0"}],"id":{"product":"188764648e874fd98523f669c6e5a042","version":"086904fd367848a3becd1434390daa32"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T04:18:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icea.sys","sw_key_expectedpath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7314752","datemodified":"2021-07-21T19:45:56","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"0519bb9523dd61e447a822ec24bbfd9b","name":"netxtreme2_bl-kmp-default-7.14.80_k5.3.18_22-5.sles15sp2.x86_64.rpm","release":"2021-07-21T19:14:13","revision":"0","sha1sum":"27d6ec70230cbc52fb570bd6d33afe06569e6f8b","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"},{"bytes":"7483237","datemodified":"2021-07-21T19:48:54","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/bnx2.ko","./lib/modules/5.3.18-57-default/updates/bnx2fc.ko","./lib/modules/5.3.18-57-default/updates/bnx2i.ko","./lib/modules/5.3.18-57-default/updates/bnx2x.ko","./lib/modules/5.3.18-57-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2_bl-kmp-default/component.xml"],"md5sum":"8e7a56fb6f647fd3e3cf249f1bb0da9a","name":"netxtreme2_bl-kmp-default-7.14.80_k5.3.18_57-5.sles15sp3.x86_64.rpm","release":"2021-07-21T19:14:13","revision":"0","sha1sum":"85ffbb95b1c9266500a2092d61c67ce1dd1c70be","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3da3feeb"],"type_of_change":"0","version":"7.14.80-5"}],"id":{"product":"f76235dc1aee44f3804452ef8c8047d0","version":"7901fe6be5cd4faeb301af32dbd3635c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbEマルチファンクションドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the driver fails to load in NPAR mode when RoCE Data Center Quantized Congestion Notification (DCQCN) is enabled.<br />\nThis product addresses a system crash seen when unloading and reloading the RoCE driver only.<br />\nThis product addresses a system crash seen during multiple reboots of virtual machines using VFs and RDMA.<br />\nThis product addresses a system crash seen when injecting a fw_assert on a NIC PF.<br />\nThis product corrects an issue where a system fails to shutdown after reboots in iSCSI BFS.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports&nbsp;SUSE Linux Enterprise Server 15&nbsp;SP3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4891060","datemodified":"2021-07-23T07:33:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/CP048165.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/TTMRESD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0f923833e9-HPD9-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048165.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048165.scexe"],"md5sum":"b678cb94a2e3581a163335c3122a2076","name":"firmware-hdd-0f923833e9-HPD9-6.1.x86_64.rpm","release":"2021-07-23T07:20:07","revision":"0","sha1sum":"608603bc1f12e591a5ddc9af55e84aa49ae164fd","size":"4MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"15b4903e0d104da184afbca47ab6234b","version":"60fe2e23f7c343f484ce686336089385"},"installation":{"command":"CP040306.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:29:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"可升级 HPE ProLiant Gen9 扩展卡上机柜固件的补充更新/在线 ROM Flash 智能组件"},{"lang":"tw","x_late":"補充更新/線上 ROM 更新智慧型元件，可升級 HPE ProLiant Gen9 擴充的機櫃韌體"},{"lang":"ko","x_late":"추가 업데이트/HPE 프로라이언트 Gen9 확장기에서 인클로저 펌웨어를 업그레이드하는 온라인 ROM 플래시 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダー上のエンクロージャーファームウェアをアップグレードするサプリメンタルアップデート / オンラインROMフラッシュSmartコンポーネント"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5400997","datemodified":"2021-08-16T10:52:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/CP049278.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/firmware-Signed-5.10-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049278.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049278.scexe"],"md5sum":"6a70622927fd8542d10ec407714e6e89","name":"firmware-smartarray-1f19a4a64d-5.10-1.1.x86_64.rpm","release":"2021-09-06T00:00:00","revision":"2","sha1sum":"4462667ddd38a072b4e2e69dc3883d93c6822306","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10"}],"id":{"product":"799e6d2dd6574724a67dc3ea392d2873","version":"76e49ee7c717461397b52f90313ebc9b"},"installation":{"command":"CP049278.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044963.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP044963.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-2de15b6882-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート：</em></strong></p>\n\n<ul>\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします：  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します</li>\n\t<li>CP044963.scexeスクリプトは 'scexe-compat'フォルダーにあります。'firmware-smartarray-2de15b6882-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./ CP044963.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*' にある<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（'.rpm'拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します：<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-2de15b6882-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-2de15b6882-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"cn","x_late":"Linux (x64)版补充更新/在线ROM刷新组件 – 适用于HPE智能阵列控制器和HPE HBA控制器的HPE 12Gb/s SAS扩展器固件"},{"lang":"tw","x_late":"適用於 Linux (64) 的補充更新/線上 ROM 更新元件 – 適用於 HPE Smart Array 控制器和 HPE HBA 控制器的 HPE 12Gb/s SAS 擴充韌體"},{"lang":"ko","x_late":"Linux(x64)용 추가 업데이트/온라인 ROM 플래시 구성 요소 - HPE 스마트 어레이 컨트롤러 및 HPE HBA 컨트롤러용 HPE 12Gb/s SAS 익스팬더 펌웨어"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE 12 Gb/s SASエキスパンダーファームウェア for HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-11T08:51:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1382239","datemodified":"2021-12-13T20:04:18","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-auxiliary.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/base/auxiliary.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"f262648cf562fcad63ea49a768eebb83","name":"kmod-mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel7u8.x86_64.rpm","release":"2021-12-13T18:44:25","revision":"0","sha1sum":"9c0b68c4c4c0becb5cfdd6d53fd09df004dfc6d0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"},{"bytes":"1347129","datemodified":"2021-12-13T20:02:54","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/dpcp-1.1.17","./usr/share/doc/dpcp-1.1.17/README","./usr/share/doc/libibverbs-55mlnx37","./usr/share/doc/libibverbs-55mlnx37/libibverbs.md","./usr/share/doc/librdmacm-55mlnx37","./usr/share/doc/librdmacm-55mlnx37/librdmacm.md","./usr/share/doc/libvma-9.4.0","./usr/share/doc/libvma-9.4.0/CHANGES","./usr/share/doc/libvma-9.4.0/README","./usr/share/doc/mlnx-tools-5.2.0","./usr/share/doc/mlnx-tools-5.2.0/ib2ib_setup.txt","./usr/share/doc/rdma-core-55mlnx37","./usr/share/doc/rdma-core-55mlnx37/COPYING.BSD_FB","./usr/share/doc/rdma-core-55mlnx37/COPYING.BSD_MIT","./usr/share/doc/rdma-core-55mlnx37/COPYING.GPL2","./usr/share/doc/rdma-core-55mlnx37/COPYING.md","./usr/share/doc/rdma-core-55mlnx37/README.md","./usr/share/doc/rdma-core-55mlnx37/tag_matching.md","./usr/share/doc/rdma-core-55mlnx37/udev.md","./usr/share/licenses/dpcp-1.1.17","./usr/share/licenses/dpcp-1.1.17/LICENSE","./usr/share/licenses/libvma-9.4.0","./usr/share/licenses/libvma-9.4.0/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"893e40d62eeff62f5ceb525fdc9e9f73","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.rhel7u8.x86_64.rpm","release":"2021-12-13T18:44:25","revision":"0","sha1sum":"724f5f9f381a747745eada33997da4eab1da6854","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"}],"id":{"product":"63a0b4d1fd5143328925661934c3ed2a","version":"5ce7f28a1de048228c5923aac9fd210f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-5.5-OFED.5.5-0.4.4.1.rhel7u8.x86_64.rpm mlnx-ofa_kernel-5.5-OFED.5.5-0.4.4.1.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG001800JWJNR and EG002400JWJNT&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4250664","datemodified":"2021-07-24T07:04:21","file_list":["cp048242.xml","cpqsetup.exe","payload.json","setup.dll","SSKYBT512ED6.rel"],"md5sum":"3ff36e899ab3f616cf85b378be3b683e","name":"cp048242.exe","release":"2021-07-24T06:57:04","revision":"0","sha1sum":"ab751649d640b769dc1f11ce3d6f4a5ceaeec13e","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"17b00802f88a41f591cee6102caaf9d2","version":"bb502a54082c4a19a629ac188201e20b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T11:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U45_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33603050","datemodified":"2022-03-10T22:00:37","file_list":["payload.json","U45_2.62_03_08_2022.signed.flash","U45_2.62_03_08_2022.xml"],"md5sum":"f3821ae07d56a43ab31a46beff6c8a6f","name":"U45_2.62_03_08_2022.fwpkg","release":"2022-03-10T21:56:09","revision":"0","sha1sum":"79dcb14d7d448f082d01056de68020dc362e39ed","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000219"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"4bdcb7d3fc5c4d14af793003b89e365b","version":"187d982515bb47ffa99cd05ef3685bc0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:13:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"}],"sw_keys":[{"name":"U45","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB, and EH0600JDXBC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features</strong>:</p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2912280","datemodified":"2021-07-24T05:38:50","file_list":["cp048517.xml","cpqsetup.exe","payload.json","setup.dll","TA13SXD5.rel"],"md5sum":"f659aec23bf26507dd18a204bc4807fb","name":"cp048517.exe","release":"2021-07-24T05:30:04","revision":"0","sha1sum":"a17ca04f46055ce25f97d7e104ea90d8ddd2e62b","size":"2MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8de9ca424f8f4678aeecd66cdfe60068","version":"69df212698564e33ba12d5fa33f07e47"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:58:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5537739","datemodified":"2021-07-23T08:29:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/CP048077.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/STHBTND6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ac3fda26eb-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048077.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048077.scexe"],"md5sum":"8b4a8535e73bfda1f7c7500e98842e48","name":"firmware-hdd-ac3fda26eb-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:16:14","revision":"0","sha1sum":"5a86b346b2e2ddacc25f446434e5f802a3d35ba2","size":"5MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"b52adb44d0e04f40a015897db8ad0e5d","version":"92a41defd1ea44e09417c7049c8e9be0"},"installation":{"command":"CP040272.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:47:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1154128","datemodified":"2021-11-02T10:05:48","file_list":["cp047052.xml","cpqsetup.exe","cp_data.xml","install.xml","ixt65x64.cat","ixt65x64.din","ixt65x64.inf","ixt65x64.sys","ixtmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXT.dll"],"md5sum":"dd5a2ff8ca4e2d8de06f5e65a7b7ce64","name":"cp047052.exe","release":"2021-11-02T09:51:11","revision":"0","sha1sum":"fd50eccbbb6b2524ff65a33c08f2cce63f7a8dc1","size":"1MB","target_guids":[],"type_of_change":"0","version":"4.1.229.0"}],"id":{"product":"a8417355844c4be0a58d7ebc978d6631","version":"5feb0ef6fa9c4fce85f87a6805eb2c48"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixt Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixtドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXT.dll and ixtmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"}],"sw_keys":[{"name":"ixt65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 15下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"22082","datemodified":"2020-07-06T12:06:05","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-216.0.88.3.so","./usr/lib64/libbnxt_re-rdmav16.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"3f45b8c7ad6505ae9c557e6e4903d9d3","name":"libbnxt_re-216.0.88.3-sles15sp0.x86_64.rpm","release":"2020-07-06T12:03:04","revision":"0","sha1sum":"1500872c3a497d2156cf71194a6bc24e643ac476","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"216.0.88.3"}],"id":{"product":"624db0a4b73e44c99c1f052c1aef041d","version":"ed1d4fe37d2c4f4ca536ff844f6308d9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation instructions.</p>\n\n<p>Use <em>--force</em> or <em>--replacefiles</em> options while installing or updating the HPE Broadcom RoCE library on SUSE Linux Enterprise Server 15.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 15用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports&nbsp;the following network adapters.</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</li>\n</ul>\n","latest_fixes_x_late":"<p>This product adds a feature to group RoCE statistics<br />\nThis product fixes an issue to avoid VM reboot when RoCE driver was loaded on VF (of Thor).<br />\nThis product fixes RX buffer errors which reported in dmesg when running heavy jumbo traffic.</p>\n"},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now disables loading RoCE driver on VFs when Link Aggregation is enabled.</li>\n\t<li>This product now supports rdma-core v22.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot.</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U30_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11607288","datemodified":"2022-03-08T10:08:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/CP051166.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/U30_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051166.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051166.scexe"],"md5sum":"5bf2739593b3a0c3d6eec54676f9aef3","name":"firmware-system-u30-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"7d476fd0dd672893a34009123ae95cbcdcd823a6","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000205"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"1368ab3d45fb40b799c33ccbe297c322","version":"0ef54b545d1148489b8a01ae41afff33"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上 ROM 更新元件 - HPE ProLiant DL380 Gen10 (U30) 伺服器"},{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers"},{"lang":"ko","x_late":"Linux용 온라인 ROM 플래시 구성 요소 - HPE ProLiant DL380 Gen10 (U30) 서버"},{"lang":"cn","x_late":"用于 Linux 的 ROM Flash 组件 - HPE ProLiant DL380 Gen10 (U30) 服务器"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL380 Gen10(U30)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"}],"sw_keys":[{"name":"U30","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16858258","datemodified":"2021-01-27T11:50:55","file_list":["/CP046386_BUILD_3.data","/CP046386.vmexe","/CP046386.vmexe64","/CP046386.vmfile","/CP046386_VMw.zip","/CP046386.xml","/payload.json","/CP046386_VMw.zip/index.xml","/CP046386_VMw.zip/vendor-index.xml","/CP046386_VMw.zip/metadata.zip","/CP046386_VMw.zip/vib20/CP046386/HPE_bootbank_CP046386_1.27.3-7.0.0.15843807.vib","/CP046386_VMw.zip/metadata.zip/vendor-index.xml","/CP046386_VMw.zip/metadata.zip/vmware.xml","/CP046386_VMw.zip/metadata.zip/vibs/CP046386-1459263755695559488.xml","/CP046386_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046386_1.27.3-7.0.0.15843807.xml"],"md5sum":"a582fc80fae2e7c76ba8669fdfc88e1c","name":"CP046386.zip","release":"2021-01-27T11:35:07","revision":"0","sha1sum":"a91a315dd86fc8ec314aa5b21e13796eede617ef","size":"16MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27","vib_list":[{"name":"CP046386","version":"1.27.3-7.0.0.15843807"}]}],"id":{"product":"aa3d4b3746e2485289f458134b1187cd","version":"e7eec9edd68848238e978ebaedb56512"},"installation":{"command":"CP046386.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":240,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility&nbsp;for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"17000"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-03T13:27:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3415640","datemodified":"2021-07-27T12:57:02","file_list":["cp049152.xml","cpqsetup.exe","HBCQSssseFD1.rel","payload.json","setup.dll"],"md5sum":"b12a35879d4b777703d2426667b1e077","name":"cp049152.exe","release":"2021-07-27T12:49:05","revision":"0","sha1sum":"38cff43342780a5ae6f2e21a31eb19b318f6bc6c","size":"3MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"f0e80dda550e422981f666fd854cb6f6","version":"9ce35e34acf8492b9991619b738de2d9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:43:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV &nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"6335245","datemodified":"2021-07-23T09:25:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/CP048205.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/GPM883G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-db687966b4-HPG4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048205.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048205.scexe"],"md5sum":"1fd48dcae67a21ed230cf81374d98fb1","name":"firmware-hdd-db687966b4-HPG4-3.1.x86_64.rpm","release":"2021-07-23T09:12:16","revision":"0","sha1sum":"dd09a87fcb700216ac3facc16d12a7e0d6f95f5c","size":"6MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"225a3736a3d645ae82a85050bf27993e","version":"28b280620dec45c6bb98dee8614c15ad"},"installation":{"command":"CP043494.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報：</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br/>\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:30:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3654592","datemodified":"2021-07-25T14:55:08","file_list":["cp048607.xml","cpqsetup.exe","payload.json","setup.dll","SMKRASD9.rel"],"md5sum":"22efc5a0ba137b2051d33343fc339195","name":"cp048607.exe","release":"2021-07-25T14:47:05","revision":"0","sha1sum":"d9a999c46d30f9463f09dd7f25c2149f15085830","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"fc0a79d6952d41d4919e3578b5303d5a","version":"b42613000fc445edba7ba7d4fd02d469"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:37:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050814.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2436956","datemodified":"2022-01-26T03:08:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/CP050816.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/cp050814.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/cp050814.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.039-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050816.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050816.scexe"],"md5sum":"4885790508336d96009478e68a90ae31","name":"firmware-dl20gen10plus_me-06.00.03.039-1.1.x86_64.rpm","release":"2022-01-26T03:03:10","revision":"0","sha1sum":"24b64adb4690de49c2af634022d7049f15a9e8c1","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"c165fa12d9644f82b813c7e585ce9181","version":"e2f4b0eae9b5442e9eb74b07a8e2e0eb"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>Verify the RPM signature using the following steps:</strong></p>\n\n<p>Download the HPE GPG 2048-bit Public Key (hpePublicKey2048_key1.pub), which is available from the HPE SDR web site: <a href=\"https://downloads.linux.hpe.com/keys.html\" style=\"color:#0563c1; text-decoration:underline\">https://downloads.linux.hpe.com/keys.html</a></p>\n\n<p>Import the public key while logged in as root by running the following command:</p>\n\n<p>&nbsp;&nbsp; # rpm --import /path_to_the_key/file_name_of_the_key</p>\n\n<p>&nbsp;&nbsp; example # rpm --import /path_to_the_key/26C2B797.pub</p>\n\n<p><strong>Verify the RPM:</strong></p>\n\n<p>Use the rpm --checksig command to validate and verify the digital signature of the signed file. The output from the command indicates the validity of the signature:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig filename_of_the_rpm</p>\n\n<p>&nbsp;&nbsp; example result #&nbsp; rpm --checksig &lt;filename&gt;.rpm</p>\n\n<p>&nbsp; &lt;filename&gt;.rpm: digests signatures OK</p>\n\n<p>If your file does not pass verification or you do not have the Hewlett Packard Enterprise Company public key installed, you may see an error:</p>\n\n<p>&nbsp;&nbsp; # rpm --checksig sample_file.rpm</p>\n\n<p>&nbsp;&nbsp; sample_file.rpm: (SHA1) DSA sha1 md5 (GPG) NOT OK (MISSING KEYS: key#s)</p>\n\n<p>In this case then do not install the rpm. This means the file has been modified in some way since being released from Hewlett Packard Enterprise Company.</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-20T09:39:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Automatic Server Recovery Driver manages the ASR hardware timer, which will reset the server in the event of an operating system lockup."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"588328","datemodified":"2021-08-24T07:55:54","file_list":["cp047544.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"md5sum":"ac50a16d58ad275638793e03f0fb3be3","name":"cp047544.exe","release":"2021-08-24T07:54:05","revision":"0","sha1sum":"9c7d2d00dc3d2c5de027296011115b65445ca3db","size":"574KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"type_of_change":"0","version":"4.7.1.0"}],"id":{"product":"8c2329b4625b415f9c19a0c86db985e1","version":"4a8f30d145fd4bc2a2f19c61db4b0a68"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33061590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-15T07:22:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nechesasr.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17509833","datemodified":"2021-08-26T18:53:26","file_list":["/CP048346_BUILD_2.data","/CP048346.vmexe","/CP048346.vmexe64","/CP048346.vmfile","/CP048346_VMw.zip","/CP048346.xml","/payload.json","/CP048346_VMw.zip/index.xml","/CP048346_VMw.zip/vendor-index.xml","/CP048346_VMw.zip/metadata.zip","/CP048346_VMw.zip/vib20/CP048346/HPE_bootbank_CP048346_HPG6.2-7.0.0.15843807.vib","/CP048346_VMw.zip/metadata.zip/vendor-index.xml","/CP048346_VMw.zip/metadata.zip/vmware.xml","/CP048346_VMw.zip/metadata.zip/vibs/CP048346-7396468137369311180.xml","/CP048346_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048346_HPG6.2-7.0.0.15843807.xml"],"md5sum":"5dc4e43e961589935f9c614a73ec6cf0","name":"CP048346.zip","release":"2021-08-26T18:48:08","revision":"0","sha1sum":"c9d964185cd2e9fe501a6c7a8a35cda492fe341c","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6","vib_list":[{"name":"CP048346","version":"HPG6.2-7.0.0.15843807"}]}],"id":{"product":"63f9bb70bcb94f2c9378d569ebb38b7e","version":"c02204a5edf24ba38be0ca01d58f5c51"},"installation":{"command":"CP040642.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"},{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T18:39:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n\t<li>\n\t<p>Online firmware update fails when drives are connected behind AHCI controller.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33601689","datemodified":"2022-03-08T13:47:09","file_list":["payload.json","U40_2.62_03_08_2022.signed.flash","U40_2.62_03_08_2022.xml"],"md5sum":"75d42ef968a30d3a44ddad1bc263fa7c","name":"U40_2.62_03_08_2022.fwpkg","release":"2022-03-08T13:43:46","revision":"0","sha1sum":"27b2ac722d307832ef9d9d20dec97e2b682df9dd","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"118ba074c4b3495fbd26210e14a17511","version":"526356d63b5341c99852bab4d8073642"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:11:13","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK007680GWSXN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK007680GWSXN&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3138192","datemodified":"2021-07-25T19:13:05","file_list":["cp048640.xml","cpqsetup.exe","M52008G3.rel","payload.json","setup.dll"],"md5sum":"54785e4430c47577e939ebbaa48a29a6","name":"cp048640.exe","release":"2021-07-25T19:06:04","revision":"0","sha1sum":"c34ecc2f032549e1da25bad7aa5cce9459a04cb5","size":"2MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"32232f7880984b91885a4743fd2f886d","version":"2116acedd87944c8917df65bc1b131e9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:15:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13014574","datemodified":"2021-11-30T06:41:39","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"9a44d4fe36fd71548585bb616e14383e","name":"kmod-qlgc-fastlinq-8.55.15.0-1.rhel7u8.x86_64.rpm","release":"2021-11-30T06:14:56","revision":"0","sha1sum":"a499e8bf0a8646820b14fe3d04fdbba6dc2b73a3","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.55.15.0-1"},{"bytes":"13019387","datemodified":"2021-11-30T06:38:22","file_list":["./etc/depmod.d/fastlinq.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"md5sum":"0447cbb387d4f20145431e77dabfd77e","name":"kmod-qlgc-fastlinq-8.55.15.0-1.rhel7u9.x86_64.rpm","release":"2021-11-30T06:14:56","revision":"0","sha1sum":"bfabff2ef9c81c6819b5ba95588b610c067e765d","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"type_of_change":"1","version":"8.55.15.0-1"}],"id":{"product":"882bb8e4707345cbb8f1e7ba0901abee","version":"db0757dac9da41c2b256760033acf7e0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n\t<li>This product addresses an issue where the ethernet data rate limiting doesn&#39;t work for Virtual Functions (VFs) .</li>\n\t<li>This product addresses an issue where the system crash once there are not enough number of msix vectors as requested for Virtual Functions (VFs).</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"},{"name":"kmod-qlgc-fastlinq","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"16036520","datemodified":"2021-08-26T05:58:35","file_list":["/CP045718_BUILD_4.data","/CP045718.vmexe","/CP045718.vmexe64","/CP045718.vmfile","/CP045718_VMw.zip","/CP045718.xml","/payload.json","/CP045718_VMw.zip/index.xml","/CP045718_VMw.zip/vendor-index.xml","/CP045718_VMw.zip/metadata.zip","/CP045718_VMw.zip/vib20/CP045718/HPE_bootbank_CP045718_HPK4.4-7.0.0.15843807.vib","/CP045718_VMw.zip/metadata.zip/vendor-index.xml","/CP045718_VMw.zip/metadata.zip/vmware.xml","/CP045718_VMw.zip/metadata.zip/vibs/CP045718--7474043012750851602.xml","/CP045718_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045718_HPK4.4-7.0.0.15843807.xml"],"md5sum":"0b3ecedd34b46c7d354d614a8c63aba2","name":"CP045718.zip","release":"2021-08-26T05:52:38","revision":"0","sha1sum":"ab3959580fa9e2cb8b1acfb196077ef363dc42db","size":"15MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP045718","version":"HPK4.4-7.0.0.15843807"}]}],"id":{"product":"dea3d95c6cc64119ac507d9a05278db0","version":"06aa16d93ec74d40bc7bb7ea0855d979"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB, and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T17:47:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The iLO 5 Channel Interface Driver allows software to communicate with the iLO 5 management controller.  This driver is used by the Agentless Management Service, firmware flash components, and other utilities."},{"lang":"ja","x_late":"iLO 5 Channel Interfaceドライバーは、iLO 5管理コントローラーとの通信を行うことを可能にするソフトウェアです。このドライバーは、HPE Agentless Management Service、ファームウェアフラッシュコンポーネント、およびその他ユーティリティが使用しています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"571960","datemodified":"2021-09-07T14:15:57","file_list":["cp047941.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"md5sum":"3b1979f7937137e5846a05bdf545fe14","name":"cp047941.exe","release":"2021-09-07T14:12:59","revision":"0","sha1sum":"af5e98926b3c879c44d6f4c91d98d630da7bb9a6","size":"558KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"type_of_change":"1","version":"4.7.1.0"}],"id":{"product":"e1ccea24a14a427dabc2aadd846feea9","version":"e6bf7f54c031491998c6a9c8cebf196c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2016 and Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-33071590027f","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-14T07:33:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Modified code to comply with de-branding requirements</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Snap5 platforms</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"necheschif.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8786403","datemodified":"2022-01-26T04:50:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/CP050874.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/U44_2.56_01_20_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-2.56_2022_01_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050874.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050874.scexe"],"md5sum":"f52dee4f76f9a386aaf8841b0333ef6e","name":"firmware-system-u44-2.56_2022_01_20-1.1.x86_64.rpm","release":"2022-01-26T04:43:04","revision":"0","sha1sum":"342d84555ec0efa2aee4147ba166462e9bd37a91","size":"8MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"824707fd6d4844feaef370452b0a3a3e","version":"242881980c014bfb81c575c2ecc1b92e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:52:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_265.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.65"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides updated iLO firmware that can be installed directly on supported Operating Systems. This component can also be used to obtain the firmware image for updating via iLO user interface, utilities, or through the scripting interface. Additionally, this component can be used with the HPE Smart Update Manager."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"33606986","datemodified":"2022-02-24T06:03:16","file_list":["ilo5_265.bin","ilo5_265.xml","payload.json","readme.txt"],"md5sum":"77f13adbfe8ba965041c6917c6c424fb","name":"ilo5_265.fwpkg","release":"2022-02-24T05:59:42","revision":"0","sha1sum":"02b266a8e99410a95e6b6e5742ef0f1da24521c4","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"2.65"}],"id":{"product":"2dc80c4ae4b943faadb938f8fc2b61d5","version":"d373bd8a5c9948c6aae7bca5dc5272cd"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" target=\"_blank\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" target=\"_blank\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" target=\"_blank\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"70000"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Support for Cloud based management with Compute Ops Manager (COM).</li>\n\t<li>Support for Enhanced Download Performance\n\t<ul>\n\t\t<li>This option allows to improve the performance of iLO Scriptable Virtual Media and URL based Firmware update in environments with high network latencies.</li>\n\t</ul>\n\t</li>\n\t<li>Support &nbsp;for NVIDIA A2 PCIE GPU card</li>\n</ul>\n","latest_fixes_x_late":"<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"<p>Initial build</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16828146","datemodified":"2021-08-30T19:38:33","file_list":["/CP048317_BUILD_2.data","/CP048317.vmexe","/CP048317.vmexe64","/CP048317.vmfile","/CP048317_VMw.zip","/CP048317.xml","/payload.json","/CP048317_VMw.zip/index.xml","/CP048317_VMw.zip/vendor-index.xml","/CP048317_VMw.zip/metadata.zip","/CP048317_VMw.zip/vib20/CP048317/HPE_bootbank_CP048317_HPG3.2-7.0.0.15843807.vib","/CP048317_VMw.zip/metadata.zip/vendor-index.xml","/CP048317_VMw.zip/metadata.zip/vmware.xml","/CP048317_VMw.zip/metadata.zip/vibs/CP048317--411072492867730887.xml","/CP048317_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048317_HPG3.2-7.0.0.15843807.xml"],"md5sum":"7e680fb6770aa98a705de7ab65c306e8","name":"CP048317.zip","release":"2021-08-30T19:32:50","revision":"0","sha1sum":"e2c247c8856b368271d9368603f1f380a9e4acf4","size":"16MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3","vib_list":[{"name":"CP048317","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"38555f7d1f134877a75c17953659a8a3","version":"c64b637ef61a427bb6116124abaa3868"},"installation":{"command":"CP040652.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"},{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T09:36:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.528.12"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.528.12"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.528.12"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.528.12"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.528.12"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5866132","datemodified":"2021-08-25T08:17:42","file_list":["/CP046801_BUILD_16.data","/CP046801.vmexe","/CP046801.vmexe64","/CP046801.vmfile","/CP046801_VMw.zip","/CP046801.xml","/payload.json","/CP046801_VMw.zip/index.xml","/CP046801_VMw.zip/vendor-index.xml","/CP046801_VMw.zip/metadata.zip","/CP046801_VMw.zip/vib20/CP046801/HPE_bootbank_CP046801_2021.10.01.16-6.5.0.4240417.vib","/CP046801_VMw.zip/metadata.zip/vendor-index.xml","/CP046801_VMw.zip/metadata.zip/vmware.xml","/CP046801_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046801_2021.10.01.16-6.5.0.4240417.xml","/CP046801_VMw.zip/metadata.zip/vibs/CP046801-2938576211902366567.xml"],"md5sum":"3079628c4df4c51103f6be0f71fa33ff","name":"CP046801.zip","release":"2021-08-25T08:12:05","revision":"0","sha1sum":"cd07d9b449530eacb26849ce4fde1f54b888b6a1","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046801","version":"2021.10.01.16-6.5.0.4240417"}]}],"id":{"product":"89d9be7c134e4e5d9700073722a0ffab","version":"c0f08708b21c4f279f83ad3faa9463ee"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.5"},{"lang":"ja","x_late":"Emulexファイバーチャネルホストバスアダプター for VMware vSphere 6.5用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:30:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This is a fibre channel component.</p>\n\n<p dir=\"LTR\">Added support for the following:</p>\n\n<ul dir=\"ltr\">\n\t<li>Code update to support new flash vendors</li>\n</ul>\n\n<p>Contains following firmware versions:</p>\n\n<table border=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.24</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.24</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.24</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.24</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.352.5</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.12</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: XP0120GFJSL and XP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17353483","datemodified":"2021-08-27T11:15:02","file_list":["/CP048423_BUILD_4.data","/CP048423.vmexe","/CP048423.vmexe64","/CP048423.vmfile","/CP048423_VMw.zip","/CP048423.xml","/payload.json","/CP048423_VMw.zip/index.xml","/CP048423_VMw.zip/vendor-index.xml","/CP048423_VMw.zip/metadata.zip","/CP048423_VMw.zip/vib20/CP048423/HPE_bootbank_CP048423_HPS4.4-7.0.0.15843807.vib","/CP048423_VMw.zip/metadata.zip/vendor-index.xml","/CP048423_VMw.zip/metadata.zip/vmware.xml","/CP048423_VMw.zip/metadata.zip/vibs/CP048423-3173615281499992228.xml","/CP048423_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048423_HPS4.4-7.0.0.15843807.xml"],"md5sum":"887d3fee42457d4341e29d1ec1ad1767","name":"CP048423.zip","release":"2021-08-27T11:09:32","revision":"0","sha1sum":"4aba33879f495a7920abf599a8fd9793ce252869","size":"16MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4","vib_list":[{"name":"CP048423","version":"HPS4.4-7.0.0.15843807"}]}],"id":{"product":"71f736a9e5684fd69f80904bf78b29e9","version":"fce7208e949d4e3ab9b4dfec39fa7d95"},"installation":{"command":"CP040520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T02:45:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on HPE Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2022"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1578640","datemodified":"2021-08-26T05:52:53","file_list":["cp047508.xml","cpqsetup.exe","cp_data.xml","ElxSmartSANInstaller.dll","ELXSMARTSANVer.exe","esmartsan_cfg_cn.xml","esmartsan_cfg_en.xml","esmartsan_cfg_ja.xml","get_ss_status.bat","SmartSAN_Readme.txt","smartsan_x64.exe","ss_disable.bat","ss_enable.bat"],"md5sum":"3a1ea1389debcc5ef3c0cd40c7ac582f","name":"cp047508.exe","release":"2021-08-26T05:48:52","revision":"0","sha1sum":"0b5267bb28cd535f920198dbc5d2463f1e1a4d62","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"60d0acd98b544d0bac0a673d97d9bb2d","version":"bfed78b17f52439cb1d1c126e1c7753c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Smart SAN Enablement Kit for Host Bus Adapters for Microsoft Windows Server 2022 (x86_64) "}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-12T07:31:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support :</p>\n\n<ul>\n\t<li>Added support for Windows 2022</li>\n</ul>\n\n<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ELXSMARTSANVer.exe","sw_key_expectedpath":"%systemdrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3659808","datemodified":"2021-07-24T05:38:04","file_list":["cp048515.xml","cpqsetup.exe","HKFLRCD6.rel","payload.json","setup.dll"],"md5sum":"06e0a06312d507f89ecdb73dd6906692","name":"cp048515.exe","release":"2021-07-24T05:30:13","revision":"0","sha1sum":"f673e5f8982e4d852d1d15637259200b0e26a7f8","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"da89b89bd1534fddb60af7c195cb4d11","version":"de336cf3f1604ebd9315c64bd804fd2d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH0300JDYTH、EH0450JDYTK、およびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:50:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component provides support for the HPE Smart Array Gen10 and Gen10Plus E-series and P-series controllers"},{"lang":"ja","x_late":"このコンポーネントは、HPE SmartアレイGen10 Gen10Plus EシリーズおよびPシリーズのコントローラーのサポートを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"739800","datemodified":"2022-02-16T06:50:26","file_list":["cp049387.xml","cpqsetup.exe","generic.dll","install.xml","smartpqi.cat","SmartPqi.inf","SmartPqi.sys"],"md5sum":"0186d562926f9dd9580d1f7e7c936adf","name":"cp049387.exe","release":"2022-02-16T06:48:41","revision":"0","sha1sum":"ea0effa7422fa15be6f3e7b29e91c5f5a5e01d2c","size":"722KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"type_of_change":"1","version":"1010.24.0.1005"}],"id":{"product":"7f5cc2735e814d67a516e6e72cb03eec","version":"d2808d73886b4671aa8150713a6dc611"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number. <br><p>From that drive and directory, execute the downloaded file."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array Gen10 and Gen10Plus Controller Driver for Windows Server 2016, Windows Server 2019 and Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T15:32:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A BSOD issue when running large transfer I/O traffic to SATA drives connected behind an expander.</li>\n\t<li>Fixed RAID1 incorrectly request when SmartPath is enabled.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added Windows 2022 support</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>A BSOD issue when running large transfer I/O traffic to SATA drives connected behind an expander.</li>\n\t<li>Fixed RAID1 incorrectly request when SmartPath is enabled.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"SmartPqi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-514180897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-560580897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-001080897a09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp047625.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-551580897a09","Version":"1.2.0.5446"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Windows Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers."},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のオンラインWindowsファームウェアコンポーネントを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"903536","datemodified":"2021-06-15T03:18:58","file_list":["cp047625.compsig","cp047625.zip","cp047627.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"67bb3a5474fad25201bbfc4466ffc6a6","name":"cp047627.exe","release":"2021-06-15T03:17:06","revision":"0","sha1sum":"a0879ad4786620fe3c35a816fd5473ed7f4033fe","size":"882KB","target_guids":["805dd01c-eb5a-1e76-8089-514180897a09","805dd01c-eb5a-1e76-8089-560580897a09","805dd01c-eb5a-1e76-8089-001080897a09","805dd01c-eb5a-1e76-8089-551580897a09"],"type_of_change":"1","version":"1.2.0.5446"}],"id":{"product":"7be61fcc837b4a3698dfdb3d9031d2e0","version":"db2c4af1fa1d47c89e07e0c9e6bb8636"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ol>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ol>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>:</strong></strong></p>\n\n<ol>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ol>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ol>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ol>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\packagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Microsoft Windows x64 - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-20T06:49:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows Server 2022 support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18361472","datemodified":"2021-08-26T14:56:07","file_list":["/CP048340_BUILD_2.data","/CP048340.vmexe","/CP048340.vmexe64","/CP048340.vmfile","/CP048340_VMw.zip","/CP048340.xml","/payload.json","/CP048340_VMw.zip/index.xml","/CP048340_VMw.zip/vendor-index.xml","/CP048340_VMw.zip/metadata.zip","/CP048340_VMw.zip/vib20/CP048340/HPE_bootbank_CP048340_HPD2.2-7.0.0.15843807.vib","/CP048340_VMw.zip/metadata.zip/vendor-index.xml","/CP048340_VMw.zip/metadata.zip/vmware.xml","/CP048340_VMw.zip/metadata.zip/vibs/CP048340--8227837453782433227.xml","/CP048340_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048340_HPD2.2-7.0.0.15843807.xml"],"md5sum":"97aa8d36e8daa1650cd953210125a29b","name":"CP048340.zip","release":"2021-08-26T14:50:49","revision":"0","sha1sum":"2e41af46517ca5cb0afc0cd594a43eee73728d6e","size":"17MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048340","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"809cff8704ac44759685c033bb7b76d3","version":"a4d487f2ee51444b9486ac8b873a9593"},"installation":{"command":"CP041451.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for ESXi - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T12:48:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWRTH, MB012000JWRTF and MB010000JWRTE "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5940752","datemodified":"2021-07-23T06:00:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/CP048143.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048143.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048143.scexe"],"md5sum":"bce3dbcd5810c5735febd919feee45da","name":"firmware-hdd-10385ef3e6-HPD2-6.1.x86_64.rpm","release":"2021-07-23T05:49:04","revision":"0","sha1sum":"466281fa21d3298e0e4863e866caa27661905187","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"1d54c8dcf99741aabe78b8a4e54d84f8","version":"31604d7d8a3a4bad85711468f220af8f"},"installation":{"command":"CP041452.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWRTH、MB012000JWRTFおよびMB010000JWRTE ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWRTH","target_guid":"4d2340a5-3042-3431-3030-304a57525448","type":"sas"},{"id":"MB012000JWRTF","target_guid":"4d2340a5-3042-3231-3030-304a57525446","type":"sas"},{"id":"MB010000JWRTE","target_guid":"4d2340a5-3042-3031-3030-304a57525445","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:19:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWRTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWRTE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWRTF","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.&nbsp;</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"15854514","datemodified":"2021-08-27T11:25:37","file_list":["/CP048424_BUILD_3.data","/CP048424.vmexe","/CP048424.vmexe64","/CP048424.vmfile","/CP048424_VMw.zip","/CP048424.xml","/payload.json","/CP048424_VMw.zip/index.xml","/CP048424_VMw.zip/vendor-index.xml","/CP048424_VMw.zip/metadata.zip","/CP048424_VMw.zip/vib20/CP048424/HPE_bootbank_CP048424_HPG1.3-7.0.0.15843807.vib","/CP048424_VMw.zip/metadata.zip/vendor-index.xml","/CP048424_VMw.zip/metadata.zip/vmware.xml","/CP048424_VMw.zip/metadata.zip/vibs/CP048424--5963524205731614587.xml","/CP048424_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048424_HPG1.3-7.0.0.15843807.xml"],"md5sum":"5c9d0bb220ea106a1385a641425f4472","name":"CP048424.zip","release":"2021-08-27T11:19:59","revision":"0","sha1sum":"d7f17e6f79cab654135515af2e8819b53c25d5e5","size":"15MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1","vib_list":[{"name":"CP048424","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"dbdc578953024bf9bb26afb2d6d4cd6a","version":"32c5eceb0f6f4d90a79c85ba7c1de19c"},"installation":{"command":"CP040667.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T02:56:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a timing issue which can cause the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用のQLogicドライバー"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1544550","datemodified":"2021-08-26T11:00:30","file_list":["/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip","/cp046817.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/qlnativefc-2.1.101.0-1OEM.600.0.0.2768847.x86_64.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/README.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/doc/release_note_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.txt","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/vib20/qlnativefc/QLogic_bootbank_qlnativefc_2.1.101.0-1OEM.600.0.0.2768847.vib","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vmware.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/bulletins/VMW-ESX-6.0.0-qlnativefc-2.1.101.0.xml","/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-16223807.zip/VMW-ESX-6.0.0-qlnativefc-2.1.101.0-offline_bundle-16223807.zip/metadata.zip/vibs/qlnativefc--7247954598143724648.xml"],"md5sum":"234df3e1e64275d32224bbb0af543e0d","name":"cp046817.zip","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"803f2828c06b882b7c434dd8b3cc0def38bfd7f1","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"2.1.101.0-1OEM.600.0.0.2768847"}]}],"id":{"product":"8c8abb08e5a24556bd3dc3dfd7b5528b","version":"f43977d470f2437da77e4118a804dc6a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.5"},{"lang":"ja","x_late":"VMware vSphere 6.5用HPE QLogicファイバーチャネルドライバーコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-26T05:19:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 2.1.101.0</p>\n","curr_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:2.1.101.0-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"},{"lang":"ja","x_late":"HPE Storage Emulexホストバスアダプター（HBA）用のVMware vSphere 6.7ファイバーチャネルドライバーキット"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"737377","datemodified":"2021-11-15T03:53:48","file_list":["/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip","/cp049965.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.14-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vibs/lpfc--6885805289219874139.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922.xml"],"md5sum":"a2a0c9e4db4e03719f9ef605bea3571b","name":"cp049965.zip","release":"2021-11-15T03:53:06","revision":"0","sha1sum":"40be272fc31c4a24af7f4e8c727476bfbcdfeb4c","size":"720KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"lpfc","version":"12.8.528.14-1OEM.670.0.0.8169922"}]}],"id":{"product":"6b8b85add4d84390b7e5eded3468099d","version":"e4fd6c145c034177b27276075dba2c0e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.7"},{"lang":"ja","x_late":"VMware vSphere 6.7用HPE Storage Emulexファイバーチャネルドライバーコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.8.528.14</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.14</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.528.14-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEMDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBT2D5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a454d4442","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEMDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3775912","datemodified":"2021-07-24T06:10:36","file_list":["cp048508.xml","cpqsetup.exe","payload.json","setup.dll","STHBT2D5.rel"],"md5sum":"7dc8590852dcde6c328cc5224ecf61fb","name":"cp048508.exe","release":"2021-07-24T06:03:09","revision":"0","sha1sum":"146b9422fd418969ddc34f3d3adb43c67495a033","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a454d4442"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"0099c8dbd23e4805b57e681e858e79b9","version":"5977465dbf4f4898a1dee5ddcef30253"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEMDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JEMDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEMDB","target_guid":"002340a5-4500-3147-3830-304a454d4442","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:31:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEMDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.039.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10 Plusサーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2285214","datemodified":"2022-01-26T04:40:47","file_list":["payload.json","SC_ML30GEN10Plus_ME_06.00.03.039.signed.bin","SC_ML30GEN10Plus_ME_06.00.03.039.xml"],"md5sum":"c728af37182ea291f001e83725e19b2b","name":"SC_ML30GEN10Plus_ME_06.00.03.039.fwpkg","release":"2022-01-26T04:39:40","revision":"0","sha1sum":"6c851a481b0a0a1d64980bf56464d5e11bc9a432","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"896b673e61904db68a62db4c589536af","version":"36f04a2c3441412abdf410512be9e193"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant ML30 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-20T08:26:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3251592","datemodified":"2021-07-24T10:35:34","file_list":["4ICRHPK3.rel","cp048693.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"c0198497cd2faefd5ec0e0a7419682c9","name":"cp048693.exe","release":"2021-07-24T10:28:04","revision":"0","sha1sum":"de93a9c85e6f4ba6499445b372132ed24966f902","size":"3MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3"}],"id":{"product":"840d26617d5744de973393a116bf720d","version":"283d383d67b2453da44789b3da9f7829"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T11:26:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed issues described in Customer Bulletin&nbsp;at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111900en_us.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel NVMe Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"},{"lang":"ja","x_late":"VMware vSphere 7.0ファイバーチャネルNVMeドライバーキットfor HPE Storage Emulexホストバスアダプター（HBA）"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"39555","datemodified":"2021-11-12T10:03:04","file_list":["/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip","/cp049953.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/vib20/brcmnvmefc/EMU_bootbank_brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vmware.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vibs/brcmnvmefc--1536773069476625033.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/bulletins/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807.xml"],"md5sum":"9db04e6c048c220a9e5b5e495dc0fe18","name":"cp049953.zip","release":"2021-11-12T10:01:49","revision":"0","sha1sum":"17fba6356d6f406dc65de3651ba858c7ea244467","size":"38KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccf06fbb4","20a6e8e4-bf33-4c71-a6bf-d9ec8e5a330c"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"brcmnvmefc","version":"12.8.528.7-1OEM.700.1.0.15843807"}]}],"id":{"product":"6388aca0e9384416957e1de0a3b220b2","version":"0174e4a63dda4c588dd40bc58d1e6a62"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel NVMe driver component for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE Storage Emulexファイバーチャネルドライバーコンポーネントfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.8.528.7</p>\n\n<p>This Driver is applicable on ESXi 7.0U2 only</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.7</p>\n\n<p>&nbsp;</p>\n\n<p>This component is supported only on ESXi 7.0U2</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"brcmnvmefc:12.8.528.7-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-ELX-brcmnvmefc:12.8.528.7-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS35, provides Windows 64-bit support for HPE MR416i-p MR416i-a MR216i-p MR216i-a controller"},{"lang":"ja","x_late":"このドライバーMegaSAS35は、HPE MR416i-p MR416i-a MR216i-p MR216i-aコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"892120","datemodified":"2021-09-08T06:03:16","file_list":["cp049482.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"md5sum":"3cc3fc7a133a5588f4ca6b5a23b342ee","name":"cp049482.exe","release":"2021-09-08T06:01:38","revision":"0","sha1sum":"5b1ffbf240a0298eb2c9b14f7fcda67d022aa008","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.716.3.0"}],"id":{"product":"4c4e15e3e8d243efae5ab2580b253cde","version":"8282ca329e734bbf9eaa901517599053"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"},{"lang":"ja","x_late":"<p>ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p MR416i-a MR216i-p MR216i-a  64-bit controller driver for Microsoft Windows 2019 edition."},{"lang":"ja","x_late":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a 64-bit コントローラードライバーfor Microsoft Windows 2019 edition。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T05:28:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"MegaSas35.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17601926","datemodified":"2021-08-26T19:49:32","file_list":["/CP048366_BUILD_2.data","/CP048366.vmexe","/CP048366.vmexe64","/CP048366.vmfile","/CP048366_VMw.zip","/CP048366.xml","/payload.json","/CP048366_VMw.zip/index.xml","/CP048366_VMw.zip/vendor-index.xml","/CP048366_VMw.zip/metadata.zip","/CP048366_VMw.zip/vib20/CP048366/HPE_bootbank_CP048366_HPGB.2-7.0.0.15843807.vib","/CP048366_VMw.zip/metadata.zip/vendor-index.xml","/CP048366_VMw.zip/metadata.zip/vmware.xml","/CP048366_VMw.zip/metadata.zip/vibs/CP048366--4442060161600011718.xml","/CP048366_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048366_HPGB.2-7.0.0.15843807.xml"],"md5sum":"311f19cfe8c73ad36ab3b6edaa340cd2","name":"CP048366.zip","release":"2021-08-26T19:43:06","revision":"0","sha1sum":"d9b83ac77b0de8bd95af07ebb8147faffb6cca1f","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB","vib_list":[{"name":"CP048366","version":"HPGB.2-7.0.0.15843807"}]}],"id":{"product":"6a439b96c74c406881767d161dad104f","version":"5bc6206478504fe2af895fd983130f30"},"installation":{"command":"CP039425.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T18:59:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.3089.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Intel NIC firmware running under Microsoft Windows Server 2016, Windows Server 2019 and Windows Server 2022"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13558272","datemodified":"2021-12-20T09:07:42","file_list":["cp050582.xml","cpqsetup.exe","for_Gen9/","for_Gen9/install.bat","for_Gen9/iqvw64e.cat","for_Gen9/iqvw64e.inf","for_Gen9/iqvw64e.sys","for_Gen9/uninstall.bat","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","FW/HPE_366FLR_G41713-00x_80001148.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","FW/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_80001146.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p50_80003371.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_800009E0.txt","FW/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","FW/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","FW/HPE_562FLR-SFP_DP_H47655-000_10p57p2_8p50_8000B749.bin","FW/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","FW/HPE_562SFP_DP_H44490-000_10p57p2_8p50_8000B748.bin","FW/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_5p50_80003372.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_5p50_80003370.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_5p50_80003373.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_SFX_OCSD_G43260-0xx_800009E1.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"1078514815bf096413df9b31df47cf3b","name":"cp050582.exe","release":"2021-12-20T08:59:12","revision":"0","sha1sum":"eb0e3d0a359e5e78c3b18f75dbae243fb20345f1","size":"12MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"be56d38accd045cca89d446f2db8440b","version":"184a218fe58f448fa6e8e27c9c5002cb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、次のカスタマーアドバイザリを参照してください。 <br />\n\thttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</li>\n\t<li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後に電源を再投入する必要があります。<br />\n\tHPE Ethernet 1Gb 2ポート368iアダプター<br />\n\tHPE Ethernet 1Gb 2ポート369iアダプター<br />\n\tHPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />\n\tHPE Ethernet 10Gb 2ポート 568FLR-MMSFP+アダプター<br />\n\tHPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-20T08:32:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where link flipping is seen with HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter.</li>\n\t<li>This product addresses an issue where the link speed isn&rsquo;t consistent with HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter when system shutdown.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product is now supported Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5232121","datemodified":"2021-07-23T08:02:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/CP048095.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048095.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048095.scexe"],"md5sum":"234b77d0d62479e694a3150d36de943d","name":"firmware-hdd-d39e7a7e75-HPG1-6.1.x86_64.rpm","release":"2021-07-23T07:48:12","revision":"0","sha1sum":"0f066196951f95f988551292f09e9227e828b7d5","size":"4MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"c20869f6e72044ccb4d2b142b029a1ef","version":"7798daf681e44902877c7a27f831b447"},"installation":{"command":"CP040351.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:20:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.56 (01/20/2022)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16809633","datemodified":"2022-01-26T06:00:55","file_list":["payload.json","U48_2.56_01_20_2022.signed.flash","U48_2.56_01_20_2022.xml"],"md5sum":"2cf6c3dc9476ec5755d0ca879e31e91f","name":"U48_2.56_01_20_2022.fwpkg","release":"2022-01-26T05:56:33","revision":"0","sha1sum":"3ecead11246a95345897643f3db0ebf6e6ed6874","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"b8b6b31789ce4119a48876ba4b89c81f","version":"9dd97af5484c4ed28c6ba058b59ef6f6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T05:32:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.\n\nNone<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"此元件套件包含適用於 Microsoft Windows Server 2016 執行的 HPE Intel i40ea 10 Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ko","x_late":"이 구성 요소 패키지에는 Microsoft Windows Server 2016에서 실행되는 HPE Intel i40ea 10기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"此组件包包含的驱动程序适用于在 Microsoft Windows Server 2016 环境下运行的 HPE Intel i40ea 10 千兆以太网卡。"},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1269920","datemodified":"2021-09-23T12:45:48","file_list":["cp047045.xml","cpqsetup.exe","cp_data.xml","i40ea65.cat","i40ea65.din","i40ea65.inf","i40ea65.sys","i40eamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInI40.dll"],"md5sum":"1b28544db9c6500a4540b45f6ff6ae0e","name":"cp047045.exe","release":"2021-09-23T12:30:52","revision":"0","sha1sum":"ec7709301cb30bbc0e94d3cddaea25dd9f1ccae0","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"4c78cfc099d944a5b3790aa796ed8a49","version":"deb4caaea9ed48558d34f2eb338d7531"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>[インストール]ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows Server 2016 的 HPE Intel i40ea 驅動程式"},{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2016"},{"lang":"ko","x_late":"Windows Server 2016용 HPE Intel i40ea 드라이버"},{"lang":"cn","x_late":"Windows Server 2016 版 HPE Intel i40ea 驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library i40eamsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40ea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 12.0.1192.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel over Ethernet-Host Bus Adapter driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2041160","datemodified":"2021-08-27T06:01:36","file_list":["brcmdrvr-fcoe-12.0.1192.0-21.exe","cp046769.xml","cpqsetup.exe","ElxCNAInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"8e1cc5f7acf097906825db5cd961defd","name":"cp046769.exe","release":"2021-08-27T05:58:20","revision":"0","sha1sum":"1e85f0d8b3dabfafe0bb82721b7862d349f1a589","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf131b5fe"],"type_of_change":"1","version":"12.0.1192.0"}],"id":{"product":"bbe1b570fa0b489d9f3ea7ce12b8f909","version":"b8b340ec82a14c5f927d9361566340b3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>&nbsp;</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p> </p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Over Ethernet Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version 12.0.1192.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0in; margin-right:0in\">Updated to driver version 12.0.1192.0</p>\n\n<p>&nbsp;</p>\n\n<p>Removed the raw driver file folder.&nbsp; The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:<br />\n<br />\n&nbsp;&nbsp;&nbsp; brcmdrvr-fcoe-version.exe /q2 extract=2<br />\n<br />\nThe extracted files are located:<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version<br />\n<br />\nEach kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,<br />\n<br />\n&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Broadcom\\Drivers\\FCoE-version\\x64\\win2012</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"elxcna.sys","sw_key_expectedpath":"%programfiles%\\Broadcom\\AutoPilot Installer\\FCoE\\Drivers\\Storport\\x64\\Win2019"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3706384","datemodified":"2021-07-25T14:38:56","file_list":["cp048593.xml","cpqsetup.exe","HAKPFCGB.REL","payload.json","setup.dll"],"md5sum":"5d47ca1179552f3210d8bb5797bcea9f","name":"cp048593.exe","release":"2021-07-25T14:31:11","revision":"0","sha1sum":"12de3f09d4fe9d59cc7836b97c06873ce66eb526","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"8bec8c11bb254125b8c66405c5e73717","version":"13058503c89a47388f6c0217a85d0c9d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:26:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1468726","datemodified":"2021-08-26T10:14:02","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp046792.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"9bf7af2c68f2afaee67b97fa48db0751","name":"cp046792.zip","release":"2021-08-26T10:13:04","revision":"0","sha1sum":"dba528c10f76c4ee128c50572e4383246febd5d5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"1b944a04f5844e8cab35edaa8a7e8e54","version":"67368ae61ff040928fa58ebaf9216e5f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability&nbsp;&nbsp;</li>\n</ul>\n\n<p dir=\"LTR\">Updated to Driver version 12.8.317.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GEFQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304745465156","Version":"HPG8"},{"DeviceName":"MM2000GEFRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGRTG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304745465241","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000GEFQV and MM2000GEFRA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG5<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>HPG5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17368518","datemodified":"2021-08-27T06:30:32","file_list":["/CP048388_BUILD_2.data","/CP048388.vmexe","/CP048388.vmexe64","/CP048388.vmfile","/CP048388_VMw.zip","/CP048388.xml","/payload.json","/CP048388_VMw.zip/index.xml","/CP048388_VMw.zip/vendor-index.xml","/CP048388_VMw.zip/metadata.zip","/CP048388_VMw.zip/vib20/CP048388/HPE_bootbank_CP048388_HPG8.2-7.0.0.15843807.vib","/CP048388_VMw.zip/metadata.zip/vendor-index.xml","/CP048388_VMw.zip/metadata.zip/vmware.xml","/CP048388_VMw.zip/metadata.zip/vibs/CP048388--3199225999192389564.xml","/CP048388_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048388_HPG8.2-7.0.0.15843807.xml"],"md5sum":"dc8c4d78a03c252a1fda176f0215548a","name":"CP048388.zip","release":"2021-08-27T06:25:41","revision":"0","sha1sum":"97f084091a8c81a65c59cd6440750df4bfedb1e1","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304745465156","002340a5-4d00-324d-3030-304745465241"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048388","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"c19eee3c7a1046a4aeaff35e462fce56","version":"95103eef97df471cbb28099d4693e588"},"installation":{"command":"CP040658.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GEFQV and MM2000GEFRA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000GEFQVおよびMM2000GEFRAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GEFQV","target_guid":"002340a5-4d00-314d-3030-304745465156","type":"sata"},{"id":"MM2000GEFRA","target_guid":"002340a5-4d00-324d-3030-304745465241","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:15:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GEFQV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MM2000GEFRA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG6"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG6"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG6"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG6"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG6"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG6"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG6"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG6"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYRHPG6.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTL および MK003840GWTTN ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:&nbsp;&nbsp;</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3168120","datemodified":"2021-07-22T11:21:03","file_list":["4IYRHPG6.bin","cp048241.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"fbe4c69740eed18dbcb04b236fd7c9fe","name":"cp048241.exe","release":"2021-07-22T11:12:05","revision":"0","sha1sum":"216b7aa442c0c29ee37de1029a84ce481196157c","size":"3MB","target_guids":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"4ec88340a2ce4a0da239c4051a775bd6","version":"734280d0d2cb4ad3849832b98ec2aeed"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWTSV、VK000480GWTTA、VK000960GWTTB、VK001920GWTTC、VK003840GWTTD、MK000480GWTTH、MK000960GWTTK、MK001920GWTTLおよびMK003840GWTTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTTD","target_guid":"562340a5-304b-3330-3834-304757545444","type":"sata"},{"id":"MK003840GWTTN","target_guid":"4d2340a5-304b-3330-3834-30475754544e","type":"sata"},{"id":"VK001920GWTTC","target_guid":"562340a5-304b-3130-3932-304757545443","type":"sata"},{"id":"MK001920GWTTL","target_guid":"4d2340a5-304b-3130-3932-30475754544c","type":"sata"},{"id":"VK000960GWTTB","target_guid":"562340a5-304b-3030-3936-304757545442","type":"sata"},{"id":"MK000960GWTTK","target_guid":"4d2340a5-304b-3030-3936-30475754544b","type":"sata"},{"id":"VK000480GWTTA","target_guid":"562340a5-304b-3030-3438-304757545441","type":"sata"},{"id":"MK000480GWTTH","target_guid":"4d2340a5-304b-3030-3438-304757545448","type":"sata"},{"id":"VK000240GWTSV","target_guid":"562340a5-304b-3030-3234-304757545356","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T10:41:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWTTD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTTB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTTA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWTTC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWTSV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWTTH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWTTL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWTTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWTTN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;1.56(D)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"13759645","datemodified":"2018-12-13T06:48:02","file_list":["/CP038103.vmexe","/CP038103.vmfile","/CP038103.xml","/payload.json","/README.txt"],"md5sum":"c8ac24a4e5379a01c9e8bba4860a0a06","name":"CP038103.zip","release":"2018-12-13T12:28:04","revision":"0","sha1sum":"1d5b8634f2c3958124e78558bb54998a24ae5107","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56","vib_list":[]}],"id":{"product":"4c73b927073e4ea9b7b9d214d86c215b","version":"db137c88b05045ae9dc51920d767876b"},"installation":{"command":"CP038103.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB&nbsp; Key&nbsp;Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 8.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />\n<br />\n     オフライン（</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>）：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加しました。</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li><strong>SUM 8.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n <br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウト</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 45xx Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-12-15T07:45:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for the HPE Blade QLogic NX2 10/20 GbE Multifunction Gigabit Server Adapters for Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade QLogic NX2 10/20 GbEマルチファンクションGigabitサーバーアダプタードライバーfor Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This component contains the following drivers:</p>\n\n<ul>\n\t<li>10GbE VBD driver version 7.13.206.0</li>\n\t<li>NDIS 6.0 driver version 7.13.198.0</li>\n\t<li>FCoE offload driver version 7.14.24.0</li>\n\t<li>FCoE crash dump driver version 7.13.7.0</li>\n\t<li>iSCSI offload driver version 7.14.17.0</li>\n\t<li>iSCSI crash dump driver version 7.13.5.0</li>\n</ul>\n"}],"files":[{"bytes":"3369720","datemodified":"2021-08-12T05:46:10","file_list":["bcm10ginstaller.dll","bnxfcdo.sys","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp047540.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys"],"md5sum":"c77a9b4ef4ee3b8b6f3dd19a202421d7","name":"cp047540.exe","release":"2021-08-12T05:29:30","revision":"0","sha1sum":"381715feafa558e73ab5789e5e956bd7314179d5","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"type_of_change":"0","version":"7.13.206.0"}],"id":{"product":"4a7b934c55fe47768eb7c9f45376dbee","version":"3d983fc42f594c43954cbb888d973f87"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade QLogic NX2 10/20 GbE マルチファンクションドライバーfor Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5000"},"supported_devices":[{"dev":"168E","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1933","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c22fa","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1917","type":"pci","ven":"14E4"},{"dev":"16A2","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a2103c1916","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1916","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c22fa","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1933","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"22FA","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c22fa","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1916","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1916","type":"pci","ven":"14E4"},{"dev":"16A4","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16a4103c1917","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now provides non-SRIOV NIC switch and UDP hash support for Windows Server 2016.</p>\n","latest_fixes_x_late":"<p>This product corrects a Windows Stop Error (BSOD) seen when uninstalling the NDIS driver.<br />\nThis product corrects a BSOD with error code 7E seen when a system is heavily loaded with network traffic.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This driver corrects an issue which results in a Windows Stop Error (BSOD) when an invalid vPort ID is used with NIC VMSwitch.<br />\nThe driver addresses an issue where a network is intermittently disconnected when Virtual Machine Queue (VMQ) is enabled.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"evbda.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"lang":"ja","x_late":"HPE Storageファイバーチャネル(FC)アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター(HBA)ドライバーを提供する、バージョン12.8.351.7 のEmulex Storportドライバーfor Extended Systemが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2312512","datemodified":"2021-11-15T03:36:33","file_list":["cp049960.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"c4e170b50f6b437b0fb01da26acc6cae","name":"cp049960.exe","release":"2021-11-15T03:33:52","revision":"0","sha1sum":"f5eab980a1b053b61e2489ef57670b4c342e18a0","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"d217387da75b452f91f63bc9a4605e37","version":"b1b5d1732b604d408ff503c5654626b7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows (x64) -&nbsp; MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5391112","datemodified":"2021-07-24T10:59:29","file_list":["cp048684.xml","cpqsetup.exe","GP1725b0HPK3.rel","payload.json","setup.dll"],"md5sum":"7f31b60374177819c8d62735dd2d6cad","name":"cp048684.exe","release":"2021-07-24T10:51:08","revision":"0","sha1sum":"05d4a0a099d95fcdcdcd23315990acd456e41926","size":"5MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3"}],"id":{"product":"12eaa829eeb841af89f7ea134993346e","version":"5b9b64b8ad70467f918a59c513a7499d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:19:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"3006048","datemodified":"2021-12-07T04:48:40","file_list":["cp050181.xml","cpqsetup.exe","payload.json","setup.dll","TA15SEn0HPD5.REL"],"md5sum":"5621be01f7bfe5b82515b72b3a190948","name":"cp050181.exe","release":"2021-12-07T04:39:21","revision":"0","sha1sum":"cfad15dfedfef151450b2f7a714e7178a17a20a3","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"d09d3bc174174ab69b229c1370a5ce48","version":"5c74914e285c4326add4e4c98a5ec1a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\\\packagesディレクトリに置きます。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:25:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.039.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"FWPKG","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 Plus SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 Plus SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2285216","datemodified":"2022-01-26T02:54:04","file_list":["payload.json","SC_DL20GEN10Plus_ME_06.00.03.039.signed.bin","SC_DL20GEN10Plus_ME_06.00.03.039.xml"],"md5sum":"8380da78c0375513c3011be50a827c18","name":"SC_DL20GEN10Plus_ME_06.00.03.039.fwpkg","release":"2022-01-26T02:52:28","revision":"0","sha1sum":"54fdabb827bf0a25f544bf8b2da42ff7e91dffc7","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"9a8025d60954436ba6fa5cef6da3dd18","version":"f7bc67dca0eb42d7b168037d59ce3490"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - Server Platform Services（SPS）ファームウェアfor HPE ProLiant DL20 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-20T09:40:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB6000JVYYV&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3695480","datemodified":"2021-07-25T15:55:15","file_list":["cp048615.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6SD2.rel"],"md5sum":"c98e22e7da7f3691c5b06a2d287e67f9","name":"cp048615.exe","release":"2021-07-25T15:47:05","revision":"0","sha1sum":"45468c22ab9c738f7f6f23a7d5a9d060997ab9a3","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"eec8feb6cff84dc79bfbc2fc3ee22488","version":"4f6df427c5a84b978ab58bab012ca65e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:07:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MR000240GWFLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3234-304757464c55","Version":"HPGG"},{"DeviceName":"MR000480GWFLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3438-304757464c56","Version":"HPGG"},{"DeviceName":"VR000480GWFMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757464d44","Version":"HPGG"},{"DeviceName":"MR000960GWFMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3030-3936-304757464d41","Version":"HPGG"},{"DeviceName":"VR000960GWFME","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3936-304757464d45","Version":"HPGG"},{"DeviceName":"MR001920GWFMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3052-3130-3932-304757464d42","Version":"HPGG"},{"DeviceName":"VR001920GWFMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100MGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3130-3932-304757464d43","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB&nbsp;and VR001920GWFMC Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGE<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGE</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16471512","datemodified":"2021-08-27T07:44:07","file_list":["/CP048402_BUILD_3.data","/CP048402.vmexe","/CP048402.vmexe64","/CP048402.vmfile","/CP048402_VMw.zip","/CP048402.xml","/payload.json","/CP048402_VMw.zip/index.xml","/CP048402_VMw.zip/vendor-index.xml","/CP048402_VMw.zip/metadata.zip","/CP048402_VMw.zip/vib20/CP048402/HPE_bootbank_CP048402_HPGG.3-7.0.0.15843807.vib","/CP048402_VMw.zip/metadata.zip/vendor-index.xml","/CP048402_VMw.zip/metadata.zip/vmware.xml","/CP048402_VMw.zip/metadata.zip/vibs/CP048402--5405200051967956877.xml","/CP048402_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048402_HPGG.3-7.0.0.15843807.xml"],"md5sum":"148c074d7cb05f506fdf7877c2750e33","name":"CP048402.zip","release":"2021-08-27T07:38:51","revision":"0","sha1sum":"5d6476a1eb98650cea28a476d1e2f9547fb580bc","size":"15MB","target_guids":["4d2340a5-3052-3030-3234-304757464c55","4d2340a5-3052-3030-3438-304757464c56","562340a5-3052-3030-3438-304757464d44","4d2340a5-3052-3030-3936-304757464d41","562340a5-3052-3030-3936-304757464d45","4d2340a5-3052-3130-3932-304757464d42","562340a5-3052-3130-3932-304757464d43"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP048402","version":"HPGG.3-7.0.0.15843807"}]}],"id":{"product":"d2d1d9a632e643969f5a1799b83f981a","version":"cbe86d0b561642559c503dd3dd0302e2"},"installation":{"command":"CP041315.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MR000240GWFLU, MR000480GWFLV, VR000480GWFMD, MR000960GWFMA, VR000960GWFME, MR001920GWFMB and VR001920GWFMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MR000240GWFLU、MR000480GWFLV、VR000480GWFMD、MR000960GWFMA、VR000960GWFME、MR001920GWFMBおよびVR001920GWFMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VR001920GWFMC","target_guid":"562340a5-3052-3130-3932-304757464d43","type":"sata"},{"id":"MR001920GWFMB","target_guid":"4d2340a5-3052-3130-3932-304757464d42","type":"sata"},{"id":"VR000960GWFME","target_guid":"562340a5-3052-3030-3936-304757464d45","type":"sata"},{"id":"MR000960GWFMA","target_guid":"4d2340a5-3052-3030-3936-304757464d41","type":"sata"},{"id":"VR000480GWFMD","target_guid":"562340a5-3052-3030-3438-304757464d44","type":"sata"},{"id":"MR000480GWFLV","target_guid":"4d2340a5-3052-3030-3438-304757464c56","type":"sata"},{"id":"MR000240GWFLU","target_guid":"4d2340a5-3052-3030-3234-304757464c55","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T19:55:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MR000480GWFLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000960GWFMA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR001920GWFMC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000960GWFME","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR001920GWFMB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000480GWFMD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MR000240GWFLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"17013326","datemodified":"2021-08-30T04:50:23","file_list":["/CP049157_BUILD_2.data","/CP049157.vmexe","/CP049157.vmexe64","/CP049157.vmfile","/CP049157_VMw.zip","/CP049157.xml","/payload.json","/CP049157_VMw.zip/index.xml","/CP049157_VMw.zip/vendor-index.xml","/CP049157_VMw.zip/metadata.zip","/CP049157_VMw.zip/vib20/CP049157/HPE_bootbank_CP049157_HPD1.2-7.0.0.15843807.vib","/CP049157_VMw.zip/metadata.zip/vendor-index.xml","/CP049157_VMw.zip/metadata.zip/vmware.xml","/CP049157_VMw.zip/metadata.zip/vibs/CP049157-1279167040823740025.xml","/CP049157_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049157_HPD1.2-7.0.0.15843807.xml"],"md5sum":"3ee77f733c998441e1b8df8e32b308d6","name":"CP049157.zip","release":"2021-08-30T04:45:25","revision":"0","sha1sum":"f1c8ed1fe019951c35c4b6d32cb79cbb18d0bdf3","size":"16MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1","vib_list":[{"name":"CP049157","version":"HPD1.2-7.0.0.15843807"}]}],"id":{"product":"d0558c4ca40d4c1889688fd366d72022","version":"32205c4f8a6248bab0ef42be03d928cc"},"installation":{"command":"CP040573.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T15:22:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33890477","datemodified":"2022-02-21T05:38:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/A42_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/CP050449.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050449.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050449.scexe"],"md5sum":"a00ed5b47d6ce8d17868a0ad435608e8","name":"firmware-system-a42-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T05:29:09","revision":"0","sha1sum":"c6329acea0c4ebac61fa8355859e083db8fcc848","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"f201f1f45a1041f9819da1901ffe255f","version":"5e7126f6b275443f926a8bbac0f505b7"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T07:32:38","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 7.0."},{"lang":"ja","x_late":"この製品は、VMware vSphere 7.0上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedf, version 2.2.62.0</li>\n\t<li>qedrntv, version 3.40.35.0</li>\n\t<li>qedentv, version 3.40.36.0</li>\n\t<li>qedi, version 2.19.59.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>この製品には、以下のドライバーが含まれています。</p>\n\n<ul>\n\t<li>qedf、バージョン2.2.62.0</li>\n\t<li>qedrntv、バージョン3.40.35.0</li>\n\t<li>qedentv、バージョン3.40.36.0</li>\n\t<li>qedi、バージョン2.19.59.0</li>\n</ul>\n"}],"files":[{"bytes":"5247189","datemodified":"2021-11-24T06:45:23","file_list":["/cp049986.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/vib20/qedf/QLC_bootbank_qedf_2.2.70.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/vib20/qedentv/QLC_bootbank_qedentv_3.40.39.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/vib20/qedi/QLC_bootbank_qedi_2.19.70.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.40.37.0-1OEM.700.1.0.15843807.vib","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vibs/qedf--6006313365001762423.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vibs/qedentv--3044675742675149100.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vibs/qedi-955464002861606269.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/vibs/qedrntv--6157120950056798569.xml","/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807_18563235.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_5.0.278.0-1OEM.700.1.0.15843807.xml"],"md5sum":"806353b057a5a484071d5d863512c8b3","name":"cp049986.zip","release":"2021-11-24T06:41:10","revision":"0","sha1sum":"14ea155f443d7b469893dca38b44fa28e0a48efb","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"qedf","version":"2.2.70.0-1OEM.700.1.0.15843807"},{"name":"qedentv","version":"3.40.39.0-1OEM.700.1.0.15843807"},{"name":"qedi","version":"2.19.70.0-1OEM.700.1.0.15843807"},{"name":"qedrntv","version":"3.40.37.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"70da4993d44e45a79517f24aa5d41862","version":"f270f6780819464194db05a5a7c2c2ab"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-17T06:41:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product enhances reliability via adding support for communication between firmware and drivers.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue Vmkernel logs are flooding while running the traffic.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qedi:2.19.70.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E4-CNA-Driver-Bundle:5.0.278.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qedf:2.2.70.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.40.39.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.40.37.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD5"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD5"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEn0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000300JWSJP, EG000600JWJNH and EG001200JWJNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16187527","datemodified":"2021-12-07T05:41:22","file_list":["/CP050179_BUILD_3.data","/CP050179.vmexe","/CP050179.vmexe64","/CP050179.vmfile","/CP050179_VMw.zip","/CP050179.xml","/payload.json","/CP050179_VMw.zip/index.xml","/CP050179_VMw.zip/vendor-index.xml","/CP050179_VMw.zip/metadata.zip","/CP050179_VMw.zip/vib20/CP050179/HPE_bootbank_CP050179_HPD5.3-7.0.0.15843807.vib","/CP050179_VMw.zip/metadata.zip/vendor-index.xml","/CP050179_VMw.zip/metadata.zip/vmware.xml","/CP050179_VMw.zip/metadata.zip/vibs/CP050179--3264051233218518012.xml","/CP050179_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050179_HPD5.3-7.0.0.15843807.xml"],"md5sum":"6519fb37c5d1ca143b19ef14bda95c73","name":"CP050179.zip","release":"2021-12-07T05:35:02","revision":"0","sha1sum":"e63c8466e54a32a131dd9f5250fcbcc04194c062","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP050179","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"b6cb1e645c374b3e92e6a0688121990e","version":"655985bf668c4aeea6a8a134a4000846"},"installation":{"command":"CP041563.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWSJP、EG000600JWJNHおよびEG001200JWJNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNK","target_guid":"452340a5-3047-3130-3230-304a574a4e4b","type":"sas"},{"id":"EG000600JWJNH","target_guid":"452340a5-3047-3030-3630-304a574a4e48","type":"sas"},{"id":"EG000300JWSJP","target_guid":"452340a5-3047-3030-3330-304a57534a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:19:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000300JWSJP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3402912","datemodified":"2021-07-25T19:29:26","file_list":["cp048644.xml","cpqsetup.exe","G1633HD8.rel","payload.json","setup.dll"],"md5sum":"ea5745f24d9b8fdb900c76f7d2e5dbbb","name":"cp048644.exe","release":"2021-07-25T19:22:04","revision":"0","sha1sum":"b5648fd5aa42852937ce537190db4fcab045b292","size":"3MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"2ce3ac2092b94fa1b8631b7964992fb7","version":"7cebe83290db4e648c7da439fe9de698"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:52:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEQUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745515554","Version":"HPGB"},{"DeviceName":"MB8000GEQUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHc8HaoeFGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304745515555","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GEQUT and MB8000GEQUU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPGA</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3685240","datemodified":"2021-07-25T15:23:22","file_list":["cp048611.xml","cpqsetup.exe","HAHc8HaoeFGB.REL","payload.json","setup.dll"],"md5sum":"1f879e62379cb58367c51df84a217480","name":"cp048611.exe","release":"2021-07-25T15:16:05","revision":"0","sha1sum":"f5fefe5a8203b8b0797975c9ac6d1112f22ae8ed","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745515554","002340a5-4d00-3842-3030-304745515555"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"5eebb17653054977b3ae3cbb9a44ff98","version":"e37d79d849da44039c3fcf2da5954a5d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEQUT and MB8000GEQUU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB6000GEQUTおよびMB8000GEQUUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEQUT","target_guid":"002340a5-4d00-3642-3030-304745515554","type":"sata"},{"id":"MB8000GEQUU","target_guid":"002340a5-4d00-3842-3030-304745515555","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:25:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n\t<li>Online firmware update fails when drives are connected behind AHCI controller.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was only found during supplier ongoing reliability testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000GEQUU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQUT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5763821","datemodified":"2021-08-26T09:00:22","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"fc13e218d93edb7162b9049ce286659f","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u8.x86_64.rpm","release":"2021-08-26T08:45:18","revision":"0","sha1sum":"815d85f988b096eeb4823b23c2fa6d0d7da55d76","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"c54f04999d6b49af842950ebb0be7aac","version":"9f0fd562555842c09e2eb9adddbf3326"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:51:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Improve detection and recovery from conditions described in customer advisory available at <a href=\"http://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400KEFHN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304b4546484e","Version":"HPK4"},{"DeviceName":"MO0800KEFHP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304b45464850","Version":"HPK4"},{"DeviceName":"MO1600KEFHQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304b45464851","Version":"HPK4"},{"DeviceName":"MO2000KEFHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324f-3030-304b45464852","Version":"HPK4"},{"DeviceName":"MT0800KEXUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3054-3830-304b45585555","Version":"HPK4"},{"DeviceName":"MT1600KEXUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3154-3630-304b45585556","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU, and MT1600KEXUV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2877000","datemodified":"2021-07-25T12:16:47","file_list":["4IFDHPK4.rel","cp048475.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"2f46972b81c112709218f2d4a6056450","name":"cp048475.exe","release":"2021-07-25T12:08:05","revision":"0","sha1sum":"3372a7e6a47b04b007dda59e2868bbc775328125","size":"2MB","target_guids":["002340a5-4d00-304f-3430-304b4546484e","002340a5-4d00-304f-3830-304b45464850","002340a5-4d00-314f-3630-304b45464851","002340a5-4d00-324f-3030-304b45464852","002340a5-4d00-3054-3830-304b45585555","002340a5-4d00-3154-3630-304b45585556"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"d005de5acf9c47539dbd7a9056630a05","version":"80087d8d475f462e8a9cee1c6620a50d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\<SPP root folder>\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリに配置します。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) -  MO0400KEFHN, MO0800KEFHP, MO1600KEFHQ, MO2000KEFHR, MT0800KEXUU and MT1600KEXUV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows(x64)- MO0400KEFHN、MO0800KEFHP、MO1600KEFHQ、MO2000KEFHR、MT0800KEXUU、およびMT1600KEXUVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MT0800KEXUU","target_guid":"002340a5-4d00-3054-3830-304b45585555","type":"nvme"},{"id":"MT1600KEXUV","target_guid":"002340a5-4d00-3154-3630-304b45585556","type":"nvme"},{"id":"MO0400KEFHN","target_guid":"002340a5-4d00-304f-3430-304b4546484e","type":"nvme"},{"id":"MO0800KEFHP","target_guid":"002340a5-4d00-304f-3830-304b45464850","type":"nvme"},{"id":"MO1600KEFHQ","target_guid":"002340a5-4d00-314f-3630-304b45464851","type":"nvme"},{"id":"MO2000KEFHR","target_guid":"002340a5-4d00-324f-3030-304b45464852","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T17:18:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for&nbsp;Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT0800KEXUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT1600KEXUV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0400KEFHN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO2000KEFHR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO1600KEFHQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO0800KEFHP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1307040","datemodified":"2021-12-14T01:53:22","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.4.0","./usr/share/doc/packages/libvma-9.4.0/CHANGES","./usr/share/doc/packages/libvma-9.4.0/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"6de8b44de8dace0b2290a8b541c8dd94","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.sles12sp5.x86_64.rpm","release":"2021-12-14T00:45:16","revision":"0","sha1sum":"959c6929e19f676c571a84ea68f287f9ac54289a","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.5"},{"bytes":"1638337","datemodified":"2021-12-14T01:54:36","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/base","./lib/modules/4.12.14-120-default/updates/drivers/base/auxiliary.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"af0256901dc7fc1105c68f53cc06d5d5","name":"mlnx-ofa_kernel-kmp-default-5.5_k4.12.14_120-OFED.5.5.1.0.3.1.sles12sp5.x86_64.rpm","release":"2021-12-14T00:45:16","revision":"0","sha1sum":"28bd41de8d26e4d9a5165092996fc4f978a21335","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.5"}],"id":{"product":"194ff765dcf14c3183bf0b90a60ddc0c","version":"30f2bdf5d5804a6ea512da7f73414961"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.</p>\n\n<p>To install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.sles12sp5.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.5_k4.12.14_120-OFED.5.5.0.4.4.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T) "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1071592","datemodified":"2022-01-25T06:06:02","file_list":["cp049614.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"d53b1f17c350f2ba0480dfd552f7ceed","name":"cp049614.exe","release":"2022-01-25T05:50:02","revision":"0","sha1sum":"c51106824b4630fa6fd9bd415abde66a4d737078","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"type_of_change":"1","version":"13.0.9.0"}],"id":{"product":"2433baff8f4443ed8ddae6e9a115bc4d","version":"685d7a2f1a8b423091f9ce2fe37cb103"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i350 Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"e1r.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727e0d6-f37b-447d-a9e4-5a7fb0b9dc8a","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-004080897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-524580897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-a74a80897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp048252.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"805dd01c-eb5a-1e76-8089-fc4f80897b09","Version":"2.2.0.1553"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This component provides online Windows Firmware component for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers."},{"lang":"ja","x_late":"このコンポーネントは、HPE Gen10 Plusサーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のオンラインWindowsファームウェアコンポーネントを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"936576","datemodified":"2021-06-21T07:38:38","file_list":["cp047912.xml","cp048252.compsig","cp048252.zip","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"d35c8104cd9c73144b8e33076e9b97d3","name":"cp047912.exe","release":"2021-06-21T07:37:09","revision":"0","sha1sum":"aa739dcaf627f75ea72c4425df3fbe10e749df9f","size":"914KB","target_guids":["805dd01c-eb5a-1e76-8089-004080897b09","805dd01c-eb5a-1e76-8089-524580897b09","805dd01c-eb5a-1e76-8089-a74a80897b09","805dd01c-eb5a-1e76-8089-fc4f80897b09"],"type_of_change":"1","version":"2.2.0.1553"}],"id":{"product":"51a552d45fc0461a92c1a4bbca7e081f","version":"5cd14f8f3b2a46cfab30a6b1c8f4f2bd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ol>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ol>\n\n<p><strong>To use Smart Update Manager from the&nbsp;</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong>:</strong></strong></p>\n\n<ol>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ol>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ol>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ol>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\packagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Microsoft Windows x64 - HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - HPE Gen10 Plusサーバー上のIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Plus Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue that three different capacities of Intel Optane DC Persistent Memory are identifiable&nbsp;with three individual device GUID.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:sd:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJL、およびVO015360JWZJNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5043152","datemodified":"2021-07-23T10:25:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/CP048218.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/GPM1643ASAD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048218.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048218.scexe"],"md5sum":"6f93631cf50fdbee01683d42c8e40d0f","name":"firmware-hdd-35fd24601f-HPD4-2.1.x86_64.rpm","release":"2021-07-23T10:13:06","revision":"0","sha1sum":"67f46642bdc2e92d8e1d4e8b674e12f269a70efb","size":"4MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"c4ef0470aa934a20948f1a88d8eff26d","version":"cb25d006095f435c87e27644a1b17df7"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート:</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T12:43:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 64-bit to enable the HPE Smart Array P824i-p MR controller. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE Smart Array P824i-p MRコントローラーを有効にする、64-bit SUSE LINUX Enterprise Server 12用のビルド済みバイナリドライバーモジュールを提供します。 このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"612356","datemodified":"2018-12-12T09:00:46","file_list":["./lib/modules/4.4.73-5-default","./lib/modules/4.4.73-5-default/updates","./lib/modules/4.4.73-5-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"c9b715818cbada9c64c66b8595d1e39a","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles12sp3.x86_64.rpm","release":"2019-01-28T00:00:00","revision":"1","sha1sum":"eb25d5564be2900f4bdeb675ba66b922b2fe8840","size":"598KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"},{"bytes":"641346","datemodified":"2018-12-12T08:59:40","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"5cfab7a80d4dfc97f0817bfa7e305e41","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles12sp4.x86_64.rpm","release":"2019-01-28T00:00:00","revision":"1","sha1sum":"bacf3f85ebce9dde3fcdab654ec5eb58426d65ec","size":"626KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"b78250c893a84500a966768e0af25a67","version":"69d0331d632347d888b4d8a605efda59"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit SUSE LINUX Enterprise Server 12 "},{"lang":"ja","x_late":"64-bit SUSE LINUX Enterprise Server 12用HPE SmartアレイP824i-p MRコントローラードライバー "}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-05-02T15:58:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>RC4 drop for snap4</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize and Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWCFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434644","Version":"HPG3"},{"DeviceName":"VK000480GWCFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434645","Version":"HPG3"},{"DeviceName":"VK000960GWCFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434646","Version":"HPG3"},{"DeviceName":"VK001920GWCFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757434648","Version":"HPG3"},{"DeviceName":"VK003840GWCFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475743464b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWCFD ,VK000480GWCFE ,VK000960GWCFF ,VK001920GWCFH and VK003840GWCFK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15790762","datemodified":"2021-08-27T09:32:35","file_list":["/CP048407_BUILD_2.data","/CP048407.vmexe","/CP048407.vmexe64","/CP048407.vmfile","/CP048407_VMw.zip","/CP048407.xml","/payload.json","/CP048407_VMw.zip/index.xml","/CP048407_VMw.zip/vendor-index.xml","/CP048407_VMw.zip/metadata.zip","/CP048407_VMw.zip/vib20/CP048407/HPE_bootbank_CP048407_HPG3.2-7.0.0.15843807.vib","/CP048407_VMw.zip/metadata.zip/vendor-index.xml","/CP048407_VMw.zip/metadata.zip/vmware.xml","/CP048407_VMw.zip/metadata.zip/vibs/CP048407--2459765311620867619.xml","/CP048407_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048407_HPG3.2-7.0.0.15843807.xml"],"md5sum":"e0add333e57e1286b0817ca2177c2319","name":"CP048407.zip","release":"2021-08-27T09:27:13","revision":"0","sha1sum":"8b8aeeaf7f1a1f926bb42aa617d8ce34cfd9a3d2","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757434644","562340a5-304b-3030-3438-304757434645","562340a5-304b-3030-3936-304757434646","562340a5-304b-3130-3932-304757434648","562340a5-304b-3330-3834-30475743464b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048407","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"0d1bdabb9bd2412a9e8131f41d12a1c0","version":"fde97230729f4a86a8b8584aa5a07e64"},"installation":{"command":"CP040671.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWCFD, VK000480GWCFE, VK000960GWCFF, VK001920GWCFH and VK003840GWCFK   Drives."},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWCFD、VK000480GWCFE、VK000960GWCFF、VK001920GWCFH およびVK003840GWCFK ドライブ。"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWCFK","target_guid":"562340a5-304b-3330-3834-30475743464b","type":"sata"},{"id":"VK001920GWCFH","target_guid":"562340a5-304b-3130-3932-304757434648","type":"sata"},{"id":"VK000960GWCFF","target_guid":"562340a5-304b-3030-3936-304757434646","type":"sata"},{"id":"VK000480GWCFE","target_guid":"562340a5-304b-3030-3438-304757434645","type":"sata"},{"id":"VK000240GWCFD","target_guid":"562340a5-304b-3030-3234-304757434644","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T04:18:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWCFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCFF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCFD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWCFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWCFK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19124597","datemodified":"2021-08-27T12:18:04","file_list":["/CP048434_BUILD_2.data","/CP048434.vmexe","/CP048434.vmexe64","/CP048434.vmfile","/CP048434_VMw.zip","/CP048434.xml","/payload.json","/CP048434_VMw.zip/index.xml","/CP048434_VMw.zip/vendor-index.xml","/CP048434_VMw.zip/metadata.zip","/CP048434_VMw.zip/vib20/CP048434/HPE_bootbank_CP048434_HPG4.2-7.0.0.15843807.vib","/CP048434_VMw.zip/metadata.zip/vendor-index.xml","/CP048434_VMw.zip/metadata.zip/vmware.xml","/CP048434_VMw.zip/metadata.zip/vibs/CP048434-2627125466042958914.xml","/CP048434_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048434_HPG4.2-7.0.0.15843807.xml"],"md5sum":"c1d05596b208a6be37d9fe7c493aa0a6","name":"CP048434.zip","release":"2021-08-27T12:12:42","revision":"0","sha1sum":"3e8d75d015a5058202fc9bf9215d0c7224d82e35","size":"18MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048434","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"fee6e5ef12074571bae786cf87c0e11d","version":"06e501a247cc49c3a415bec89f443a01"},"installation":{"command":"CP043495.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU, VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T10:02:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP5 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP5 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23366","datemodified":"2021-10-01T17:46:32","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"713b5c2f694ace5033a453c64dac6eca","name":"libbnxt_re-219.0.8.0-sles12sp5.x86_64.rpm","release":"2021-10-01T17:37:57","revision":"0","sha1sum":"cba79650058683af8c69b24c9a376cb41de72dde","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"219.0.8.0"}],"id":{"product":"a9179e239bb643d4b08c6272f4499a35","version":"72986bad8a2b47d388616937dddc16c7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">インボックスライブラリと競合する可能性のあるHPE Broadcom RoCEライブラリをインストールまたはアップデートするときは、--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP5"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP5用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"125136","datemodified":"2021-08-11T09:30:30","file_list":["/cp047110.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.670.0.0.8169922.vib","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/vibs/igbn-4393841119758955275.xml","/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922-offline_bundle-17205327.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.670.0.0.8169922.xml"],"md5sum":"c43217d44cb09b9a70102b4aedc3d9b1","name":"cp047110.zip","release":"2021-08-11T09:27:09","revision":"0","sha1sum":"5f2b8d39d3bae779bf44d52eb8f0efb2729812c7","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"91032ccb9de142bdafa34467279d1727","version":"ab67323e385142baa64455d69bccf0bc"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances the reliability of TX/RX ring hang detection and recovery procedures.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.79"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.79"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79(C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79(B)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n\n&nbsp;\n\n"}],"files":[{"bytes":"41500487","datemodified":"2021-05-19T14:36:09","file_list":["/CP047952_BUILD_4.data","/CP047952.vmexe","/CP047952.vmexe64","/CP047952.vmfile","/CP047952_VMw.zip","/CP047952.xml","/payload.json","/CP047952_VMw.zip/index.xml","/CP047952_VMw.zip/vendor-index.xml","/CP047952_VMw.zip/metadata.zip","/CP047952_VMw.zip/vib20/CP047952/HPE_bootbank_CP047952_1.79.4-7.0.0.15843807.vib","/CP047952_VMw.zip/metadata.zip/vendor-index.xml","/CP047952_VMw.zip/metadata.zip/vmware.xml","/CP047952_VMw.zip/metadata.zip/vibs/CP047952--5595623553943562264.xml","/CP047952_VMw.zip/metadata.zip/bulletins/Smart-Component-CP047952_1.79.4-7.0.0.15843807.xml"],"md5sum":"05022d855fd3ca04c9e7b2560ac65ffc","name":"CP047952.zip","release":"2021-05-19T14:12:06","revision":"0","sha1sum":"e685c98a99e69d3f791fa948ef5305b5181dcf61","size":"39MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"1.79","vib_list":[{"name":"CP047952","version":"1.79.4-7.0.0.15843807"}]}],"id":{"product":"a57e8b5260a8406f910d3b1039eaf2da","version":"93fead21f968462a827638ab6f2f2875"},"installation":{"command":"CP047952.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a></li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP</li>\n\t<li>Add the component to the SPP</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run SUM</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, for the firmware update to take effect</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Backplane Expander Firmware"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-06-17T03:27:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Update Note with publish requirement</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWJPD, VK000480GWJPE, VK000960GWJPF,V K001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK,MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"23503184","datemodified":"2021-08-27T13:01:18","file_list":["/CP048444_BUILD_2.data","/CP048444.vmexe","/CP048444.vmexe64","/CP048444.vmfile","/CP048444_VMw.zip","/CP048444.xml","/payload.json","/CP048444_VMw.zip/index.xml","/CP048444_VMw.zip/vendor-index.xml","/CP048444_VMw.zip/metadata.zip","/CP048444_VMw.zip/vib20/CP048444/HPE_bootbank_CP048444_HPG5.2-7.0.0.15843807.vib","/CP048444_VMw.zip/metadata.zip/vendor-index.xml","/CP048444_VMw.zip/metadata.zip/vmware.xml","/CP048444_VMw.zip/metadata.zip/vibs/CP048444-2996869717332519316.xml","/CP048444_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048444_HPG5.2-7.0.0.15843807.xml"],"md5sum":"78b64245a76f92a646e9c8d940664801","name":"CP048444.zip","release":"2021-08-27T12:56:22","revision":"0","sha1sum":"189f334c34d0d19ed19ca5250efca56b32bf0f64","size":"22MB","target_guids":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP048444","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"261c2f9a8f584fd69c7ae5c1643322e4","version":"6a03900c138b4f959c1a87a6c43a7f2f"},"installation":{"command":"CP042736.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - VK000240GWJPD、VK000480GWJPE、VK000960GWJPF、VK001920GWJPH、VK003840GWJPK、MK000240GWKVK、MK000480GWJPN、MK000960GWJPPおよびMK001920GWJPQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWJPQ","target_guid":"4d2340a5-304b-3130-3932-3047574a5051","type":"sata"},{"id":"MK000240GWKVK","target_guid":"4d2340a5-304b-3030-3234-3047574b564b","type":"sata"},{"id":"MK000480GWJPN","target_guid":"4d2340a5-304b-3030-3438-3047574a504e","type":"sata"},{"id":"MK000960GWJPP","target_guid":"4d2340a5-304b-3030-3936-3047574a5050","type":"sata"},{"id":"VK003840GWJPK","target_guid":"562340a5-304b-3330-3834-3047574a504b","type":"sata"},{"id":"VK001920GWJPH","target_guid":"562340a5-304b-3130-3932-3047574a5048","type":"sata"},{"id":"VK000960GWJPF","target_guid":"562340a5-304b-3030-3936-3047574a5046","type":"sata"},{"id":"VK000480GWJPE","target_guid":"562340a5-304b-3030-3438-3047574a5045","type":"sata"},{"id":"VK000240GWJPD","target_guid":"562340a5-304b-3030-3234-3047574a5044","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T14:51:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a rare link loss issue and adds enhancements for drive reliability.</li>\n\t<li>After HPG5 firmware is downloaded to the drive, the new HPG5 firmware will be active on the drive.</li>\n\t<li>The new drive bootloader code will be activated after the next drive power cycle.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00072768en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWJPQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWJPH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWKVK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWJPN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWJPP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWJPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWJPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWJPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWJPK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"586061","datemodified":"2021-08-25T12:04:24","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"cfd8c950cd3db664f6c898bdbe0f079c","name":"elx-lpfc-kmp-default-12.8.528.7_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-08-25T11:57:06","revision":"0","sha1sum":"aa78f79fb5be194888edfca4d5bea8f6debbb039","size":"572KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"83fed5e4a427414fb0792283dd57ec37","version":"a5c99a601fce408ab9f094953837dc61"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 3 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:31:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for SLES 15 SP2</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability</li>\n</ul>\n\n<p>Updated to driver version 12.8.352.11</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for SLES 15 SP3</li>\n</ul>\n\n<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33802690","datemodified":"2022-02-08T02:49:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/CP050790.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/U47_1.58_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u47-1.58_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050790.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050790.scexe"],"md5sum":"6ee40fd978cc7adb98241576881fe419","name":"firmware-system-u47-1.58_2022_01_13-1.1.x86_64.rpm","release":"2022-02-08T02:42:40","revision":"0","sha1sum":"4c84b15dad420bc2e940585f39f5659d03412206","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"e9a45a84fc5a4ae9bee13ee0419530ca","version":"3e85b2fe0207440984a5c0b2f0fd95d7"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー（U47） "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-14T22:36:29","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52008G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VK007680GWSXN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16485311","datemodified":"2021-08-27T09:15:41","file_list":["/CP048411_BUILD_2.data","/CP048411.vmexe","/CP048411.vmexe64","/CP048411.vmfile","/CP048411_VMw.zip","/CP048411.xml","/payload.json","/CP048411_VMw.zip/index.xml","/CP048411_VMw.zip/vendor-index.xml","/CP048411_VMw.zip/metadata.zip","/CP048411_VMw.zip/vib20/CP048411/HPE_bootbank_CP048411_HPG3.2-7.0.0.15843807.vib","/CP048411_VMw.zip/metadata.zip/vendor-index.xml","/CP048411_VMw.zip/metadata.zip/vmware.xml","/CP048411_VMw.zip/metadata.zip/vibs/CP048411--1582149894279847640.xml","/CP048411_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048411_HPG3.2-7.0.0.15843807.xml"],"md5sum":"2bacb92dc5bd6b448c0d37c732863e5b","name":"CP048411.zip","release":"2021-08-27T09:10:45","revision":"0","sha1sum":"0fbc8f3479d75fee310c700c7d6c331c6686d5e1","size":"15MB","target_guids":["562340a5-304b-3730-3638-30475753584e"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048411","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"b4be4739aaa741bf83254d24ca921fd7","version":"b288152fd7da4fd6879888bc26790d51"},"installation":{"command":"CP040787.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK007680GWSXNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680GWSXN","target_guid":"562340a5-304b-3730-3638-30475753584e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T06:45:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK007680GWSXN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK, and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16471974","datemodified":"2021-08-27T09:07:11","file_list":["/CP048406_BUILD_3.data","/CP048406.vmexe","/CP048406.vmexe64","/CP048406.vmfile","/CP048406_VMw.zip","/CP048406.xml","/payload.json","/CP048406_VMw.zip/index.xml","/CP048406_VMw.zip/vendor-index.xml","/CP048406_VMw.zip/metadata.zip","/CP048406_VMw.zip/vib20/CP048406/HPE_bootbank_CP048406_HPGG.3-7.0.0.15843807.vib","/CP048406_VMw.zip/metadata.zip/vendor-index.xml","/CP048406_VMw.zip/metadata.zip/vmware.xml","/CP048406_VMw.zip/metadata.zip/vibs/CP048406-8529612673242572727.xml","/CP048406_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048406_HPGG.3-7.0.0.15843807.xml"],"md5sum":"85228e322526dececf4488091e2df596","name":"CP048406.zip","release":"2021-08-27T09:02:35","revision":"0","sha1sum":"1e669fff47ab632824c7d51e32215ed3263f9088","size":"15MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG","vib_list":[{"name":"CP048406","version":"HPGG.3-7.0.0.15843807"}]}],"id":{"product":"3a33d0d2b6ca440681703cda5e638a33","version":"a48c574e364044f69f03cf3a36d2d1af"},"installation":{"command":"CP041318.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000240GWEZB、 VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK および MK001920GWHRU ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:58:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13313483","datemodified":"2022-03-08T10:12:02","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/CP051122.xml","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/I41_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-i41-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051122.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051122.scexe"],"md5sum":"86c680ab772803344ae9d43166abcc5d","name":"firmware-system-i41-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"7b72068eaa71b82597cbdf8436c353a6afefffb1","size":"12MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"0da1225b30784f8690bf763f9cc09498","version":"b80d1bd19c634325815fe628a6d623e0"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant BL460c Gen10 (I41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant BL460c Gen10 (I41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:35:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16274199","datemodified":"2021-08-26T09:46:42","file_list":["/CP049120_BUILD_3.data","/CP049120.vmexe","/CP049120.vmexe64","/CP049120.vmfile","/CP049120_VMw.zip","/CP049120.xml","/payload.json","/CP049120_VMw.zip/index.xml","/CP049120_VMw.zip/vendor-index.xml","/CP049120_VMw.zip/metadata.zip","/CP049120_VMw.zip/vib20/CP049120/HPE_bootbank_CP049120_HPD8.3-7.0.0.15843807.vib","/CP049120_VMw.zip/metadata.zip/vendor-index.xml","/CP049120_VMw.zip/metadata.zip/vmware.xml","/CP049120_VMw.zip/metadata.zip/vibs/CP049120--3776151776463870189.xml","/CP049120_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049120_HPD8.3-7.0.0.15843807.xml"],"md5sum":"d1672e1bc0c334e6005b79ef1407265d","name":"CP049120.zip","release":"2021-08-26T09:41:35","revision":"0","sha1sum":"e10bb335eb3c600e612250226aef791d5c5bf35a","size":"15MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8","vib_list":[{"name":"CP049120","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"33bf4058d2284d31ad166fd3619cf008","version":"2f92036415e94c98a8f41dda69c0a655"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWTFD and MB012000JWTFC  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T12:19:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4889667","datemodified":"2021-08-12T19:15:43","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/CP049131.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049131.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049131.scexe"],"md5sum":"8b26ee950999964784d89702a21cedfb","name":"firmware-hdd-faf39e0ff7-HPD9-2.1.x86_64.rpm","release":"2021-08-12T19:03:04","revision":"0","sha1sum":"05875c4e901e4b5b17b6a485c67b1cb8baf07c48","size":"4MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"fcf6b49416e1460393e2103c04483878","version":"f7e57b434f4046838ce3ec9f0ca319c3"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB008000JWJRQおよびMB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:56:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5.上で動作するHPE Intel igbnアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.5.2.0が含まれています。</p>\n"}],"files":[{"bytes":"125775","datemodified":"2021-08-11T09:33:25","file_list":["/cp049060.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-igbn-1.5.2.0.xml","/VMW-ESX-6.5.0-igbn-1.5.2.0-offline_bundle-17300361.zip/metadata.zip/vibs/igbn--38488993777072084.xml"],"md5sum":"addc601d828dc9433443c0230af9b256","name":"cp049060.zip","release":"2021-08-11T09:30:05","revision":"0","sha1sum":"60d255ea3a9004a447484e88b1d640e3460fd6ee","size":"122KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"875c48447044433ba822fd2b79f25cb2","version":"fd730651f8434d54aa64c777c9cabe16"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Intel igbnドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-21T01:39:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances the reliability of TX/RX ring hang detection and recovery procedures.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"6820489","datemodified":"2021-07-25T12:35:45","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/CP048505.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95a2e5abcb-HPK4-6.1/spannmK4.rel","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048505.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048505.scexe"],"md5sum":"6ba8a73d8e07cbea437996bcddbc8d7b","name":"firmware-hdd-95a2e5abcb-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:23:05","revision":"0","sha1sum":"d52efe6b6660f8d2b081692bb680d47d87480465","size":"6MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"19705487dac745ff98bd9969d9ff7a10","version":"5e3b10823f5741d399a66e8d96a9b527"},"installation":{"command":"CP040922.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド：<em>rpm -e <rpm_package_name></em>（.rpm拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64)  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"},{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:51:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1686944","datemodified":"2021-08-18T03:08:50","file_list":["cp048044.xml","cpqsetup.exe","cp_data.xml","icea65.cat","icea65.din","icea65.inf","icea65.sys","iceamsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInICEa.dll"],"md5sum":"13121b29f5bbc360ddfac9103b68cd00","name":"cp048044.exe","release":"2021-08-18T02:55:06","revision":"0","sha1sum":"a1059444512f389e6ed09cf5edc4f14c1a359f0f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec713af7b4"],"type_of_change":"0","version":"1.9.65.0"}],"id":{"product":"d1f7ec922ab94039a6f0bbcfd0b7a0b4","version":"838b8217d60e4fa0b4d5ed2c5b115cc1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>​Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE</li>\n\t<li>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icea65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1340072","datemodified":"2022-01-25T15:44:00","file_list":["cp049615.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"47d9103ba93fba52d72a3540aecd6833","name":"cp049615.exe","release":"2022-01-25T15:30:06","revision":"0","sha1sum":"a940d1a204533412438779d016743b5eface79c8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"type_of_change":"1","version":"1.13.8.0"}],"id":{"product":"000bfbde35e84381b78976b2c1748662","version":"9663b2fe803f474ca81b239affc6ebda"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel iavf Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1889","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-188980860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1889","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"iavf.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4883262","datemodified":"2021-07-23T06:23:34","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/CP048158.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/TTMRNSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-46fc43ab26-HPD4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048158.scexe"],"md5sum":"75337d4d9d30e38f23430ba87a6aab38","name":"firmware-hdd-46fc43ab26-HPD4-8.1.x86_64.rpm","release":"2021-07-23T06:09:05","revision":"0","sha1sum":"86d96d2b02cc2e4f4dded742a156dd472a364707","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"a583c05eda574560bf7c625d7e1d2b1c","version":"84e37f1969da4a13949b4ab32fb6da90"},"installation":{"command":"CP040290.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T15:22:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MB2000GCWLT, MB3000GCWLU, and MB4000GCWLV Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5182136","datemodified":"2021-07-23T06:13:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/CP048148.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/HMKPB6G4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2e70ce7412-HPG4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048148.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048148.scexe"],"md5sum":"0b23095a0158518cef6ccd3aac22587f","name":"firmware-hdd-2e70ce7412-HPG4-10.1.x86_64.rpm","release":"2021-07-23T06:00:10","revision":"0","sha1sum":"6d5be39253a2e9d103502065e01cf8400f5bad8f","size":"4MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"75970c81b36f443fbbff409af0bea2a1","version":"549d2cecda784500a5832eb59aadaf16"},"installation":{"command":"CP040289.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000GCWLT、MB3000GCWLUおよびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:45:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5177284","datemodified":"2021-07-23T09:44:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/CP048211.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/GPM1643SAMD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1e51a57347-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048211.scexe"],"md5sum":"0207d02b65ded1d7997a33f7ad468a03","name":"firmware-hdd-1e51a57347-HPD8-5.1.x86_64.rpm","release":"2021-07-23T09:31:14","revision":"0","sha1sum":"5196e1ef522d20c25ddbe80e4d1040af2304c4c2","size":"4MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8"}],"id":{"product":"36bcc8676cfa4135862a614c063902e6","version":"510c3d95562d4e02a4bde7d1d1cb9060"},"installation":{"command":"CP042632.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:56:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools (iSUT) is an application which enables firmware and software deployment via the iLO management network using the server’s local administrator credentials. iSUT can run as a service when working with HPE OneView managed servers or iLO Amplifier Pack or in an On Demand mode. iSUT requires a Service Pack for ProLiant-based ISO containing Smart Update Manager version 8.0.0 or later and an iLO Advanced Pack license for deployment."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"7771970","datemodified":"2022-02-09T08:56:59","file_list":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"md5sum":"501edd1f9d0329a64ec06ac0fd2200d2","name":"sut-2.9.1-22.linux.x86_64.rpm","release":"2022-02-09T08:52:46","revision":"0","sha1sum":"1a94a5e316fc2272d9210246c3a98df78effcd60","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"type_of_change":"1","version":"2.9.1.0"}],"id":{"product":"b3a8e7e2c4ea466a9b404955f474449e","version":"1623f09c058341ba9ddf85378c593bdd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the rpm package to a directory on your hard drive and change to that directory. Install by typing rpm -Uvh hpsut-XXX.x86_64.rpm.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools for Linux x64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c1979","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3306","subdev":"1979","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c1979","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-21T06:15:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U26","value":"HPE ProLiant Easy Connect EC200a Managed Hybrid Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"sut","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK003840GWHTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16422286","datemodified":"2021-08-27T05:43:42","file_list":["/CP048383_BUILD_2.data","/CP048383.vmexe","/CP048383.vmexe64","/CP048383.vmfile","/CP048383_VMw.zip","/CP048383.xml","/payload.json","/CP048383_VMw.zip/index.xml","/CP048383_VMw.zip/vendor-index.xml","/CP048383_VMw.zip/metadata.zip","/CP048383_VMw.zip/vib20/CP048383/HPE_bootbank_CP048383_HPG8.2-7.0.0.15843807.vib","/CP048383_VMw.zip/metadata.zip/vendor-index.xml","/CP048383_VMw.zip/metadata.zip/vmware.xml","/CP048383_VMw.zip/metadata.zip/vibs/CP048383--1835485894284196433.xml","/CP048383_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048383_HPG8.2-7.0.0.15843807.xml"],"md5sum":"5e49356c4c3078b6815591ca66f205f1","name":"CP048383.zip","release":"2021-08-27T05:38:27","revision":"0","sha1sum":"95fb892d316b007de3e3eec9091b3d5c3b05f961","size":"15MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048383","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"41769df117cd4b93b1e9b45d5d971451","version":"2e2a9ef149c247129fe6913965ad4f92"},"installation":{"command":"CP041321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:39:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KWDUP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3438-304b57445550","Version":"HPK4"},{"DeviceName":"VS000960KWDUQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3053-3030-3936-304b57445551","Version":"HPK4"},{"DeviceName":"MS000400KWDUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3430-304b57445552","Version":"HPK4"},{"DeviceName":"MS000800KWDUT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannmK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3053-3030-3830-304b57445554","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR&nbsp;and MS000800KWDUT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20153731","datemodified":"2021-08-26T10:29:40","file_list":["/CP048484_BUILD_2.data","/CP048484.vmexe","/CP048484.vmexe64","/CP048484.vmfile","/CP048484_VMw.zip","/CP048484.xml","/payload.json","/CP048484_VMw.zip/index.xml","/CP048484_VMw.zip/vendor-index.xml","/CP048484_VMw.zip/metadata.zip","/CP048484_VMw.zip/vib20/CP048484/HPE_bootbank_CP048484_HPK4.2-7.0.0.15843807.vib","/CP048484_VMw.zip/metadata.zip/vendor-index.xml","/CP048484_VMw.zip/metadata.zip/vmware.xml","/CP048484_VMw.zip/metadata.zip/vibs/CP048484--2066392048896532665.xml","/CP048484_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048484_HPK4.2-7.0.0.15843807.xml"],"md5sum":"c324fbd05489d0c8f308bc6d41fc4f17","name":"CP048484.zip","release":"2021-08-26T10:24:27","revision":"0","sha1sum":"2cb1888d16c4cc28b5c82c741aa67729319e73c2","size":"19MB","target_guids":["562340a5-3053-3030-3438-304b57445550","562340a5-3053-3030-3936-304b57445551","4d2340a5-3053-3030-3430-304b57445552","4d2340a5-3053-3030-3830-304b57445554"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048484","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"496a47bbdbd9415dbba6770e6ba0409b","version":"b0c7c9755a554a80a6da33cf6687893c"},"installation":{"command":"CP040921.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - VS000480KWDUP, VS000960KWDUQ, MS000400KWDUR and MS000800KWDUT Drives"},{"lang":"ja","x_late":"VMware ESXi用オンラインNVMe SSDフラッシュコンポーネント - VS000480KWDUP、VS000960KWDUQ、MS000400KWDUR、およびMS000800KWDUTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MS000400KWDUR","target_guid":"4d2340a5-3053-3030-3430-304b57445552","type":"nvme"},{"id":"VS000960KWDUQ","target_guid":"562340a5-3053-3030-3936-304b57445551","type":"nvme"},{"id":"MS000800KWDUT","target_guid":"4d2340a5-3053-3030-3830-304b57445554","type":"nvme"},{"id":"VS000480KWDUP","target_guid":"562340a5-3053-3030-3438-304b57445550","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T07:39:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MS000800KWDUT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MS000400KWDUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000480KWDUP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VS000960KWDUQ","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Windows&nbsp;(x64) - &nbsp;VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3109280","datemodified":"2021-07-24T10:11:16","file_list":["4ICDHPK1.rel","cp048438.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"6bafd245043dc83af04d3bb361b7e655","name":"cp048438.exe","release":"2021-07-24T10:04:04","revision":"0","sha1sum":"95eb3f59b469b07a993bf8da32a2d97cfc6e64ea","size":"2MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"73c467f62ccd4e6c837bbb93fd6013e1","version":"f1f3d7bd516e4e81b2e24d54bb4e298b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T11:20:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDYTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44595448","Version":"HPD6"},{"DeviceName":"EH0450JDYTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a4459544b","Version":"HPD6"},{"DeviceName":"EH0600JDYTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFLRCD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544c","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JDYTH, EH0450JDYTK, and EH0600JDYTL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK&nbsp;and EH0600JDYTL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5558757","datemodified":"2021-07-23T08:16:29","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/CP048088.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/HKFLRCD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b9340d29be-HPD6-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048088.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048088.scexe"],"md5sum":"f18a03dfabf206bf1eb0a4986e217710","name":"firmware-hdd-b9340d29be-HPD6-9.1.x86_64.rpm","release":"2021-07-23T08:04:09","revision":"0","sha1sum":"498f3770b82688fd8833fac7b3d0b920b9d02502","size":"5MB","target_guids":["002340a5-4500-3048-3330-304a44595448","002340a5-4500-3048-3435-304a4459544b","002340a5-4500-3048-3630-304a4459544c"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"ada4d6aedd4b4604b810f81be7da5b19","version":"3d2160ca84eb445b92f71a993abc1068"},"installation":{"command":"CP040317.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH0300JDYTH, EH0450JDYTK and EH0600JDYTL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH0300JDYTH、EH0450JDYTKおよびEH0600JDYTLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EH0300JDYTH","target_guid":"002340a5-4500-3048-3330-304a44595448","type":"sas"},{"id":"EH0450JDYTK","target_guid":"002340a5-4500-3048-3435-304a4459544b","type":"sas"},{"id":"EH0600JDYTL","target_guid":"002340a5-4500-3048-3630-304a4459544c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:31:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDYTH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JDYTK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel Driver kit for HPE Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"804750","datemodified":"2021-08-26T10:46:18","file_list":["/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip","/cp046794.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.13-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/vibs/lpfc-3271848157575413779.xml","/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807_18488043.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.13-1OEM.700.1.0.15843807.xml"],"md5sum":"b20d889fa95394b91c9ba26eac34b435","name":"cp046794.zip","release":"2021-08-26T10:45:05","revision":"0","sha1sum":"d90f371eac49cb6455d0e744a6999de95076bbb8","size":"785KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7654434b","20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.528.13-1OEM.700.1.0.15843807"}]}],"id":{"product":"4e7d93b236d542028248e102c6a2c879","version":"8f96ad5256844d04928b3a828227edc3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for ESXi 7.0 U2</li>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability</li>\n</ul>\n\n<p>Updated to Driver version 12.8.329.1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.13</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"Broadcom-ELX-lpfc:12.8.528.13-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"lpfc:12.8.528.13-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2016 and Windows Server 2019 for the HPE Smart Storage SR100i Gen10 Plus SW RAID"},{"lang":"ja","x_late":"このドライバーは、Windows Server 2016およびWindows Server 2019でのHPE SmartストレージSR100i Gen10 Plus SW RAIDをサポートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1678640","datemodified":"2022-01-12T07:39:26","file_list":["cp049976.xml","cpqsetup.exe","generic.dll","install.xml","smartdq2.cat","SmartDQ2.inf","SmartDQ2a.sys","SmartDQ2co002.dll","SmartDQ2p.sys","SmartDQ2r.sys"],"md5sum":"3e134ad2e2a8c97ca1d1b9ceb23fb830","name":"cp049976.exe","release":"2022-01-12T03:18:45","revision":"0","sha1sum":"24961254284acbbcfeb20443db53101049f121aa","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec14b13c05"],"type_of_change":"1","version":"106.124.90.1233"}],"id":{"product":"4a440c014d52404fb26a46463eb5e62b","version":"01380fb28a434db38d53416bbfb517f7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Storage SR100i Gen10 Plus SW RAID Driver for Windows Server 2016 and Windows Server 2019"},{"lang":"ja","x_late":"HPE SmartストレージSR100i Gen10 Plus SW RAIDドライバーfor Windows Server 2016およびWindows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T02:30:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Correct NVMe link width information in SSA.</li>\n\t<li>Fix background surface scan may not be started for a volume configured with SSD SmartPath.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>New version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"SmartDQ2a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZPLJ1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3154-3648f52fd02c","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ3T2HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3354-3248fdc50136","Version":"EPK75H3Q"},{"DeviceName":"MZPLJ6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"EPK75H3Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-505a-4a4c-3654-3448bda98199","Version":"EPK75H3Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>EPK75H3Q</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; EPK74H3Q</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"9402131","datemodified":"2021-07-25T12:32:56","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/CP048228.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/EPK75H3Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6628fce235-EPK75H3Q-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048228.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048228.scexe"],"md5sum":"0f2ac6883fe15dfece90ef359fbb554b","name":"firmware-hdd-6628fce235-EPK75H3Q-2.1.x86_64.rpm","release":"2021-07-25T12:20:14","revision":"0","sha1sum":"21f43b17f8cdefb881ea625cdd7ff8bf15367221","size":"8MB","target_guids":["4d2340a5-505a-4a4c-3154-3648f52fd02c","4d2340a5-505a-4a4c-3354-3248fdc50136","4d2340a5-505a-4a4c-3654-3448bda98199"],"type_of_change":"2","version":"EPK75H3Q"}],"id":{"product":"77f2ff3d7ebf4999a5ec47887c09ecdf","version":"d5bbe0ba984446c08d530bb696d92764"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MZPLJ1T6HBJR-000H3, MZPLJ3T2HBJR-000H3 and MZPLJ6T4HALA-000H3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MZPLJ1T6HBJR-000H3、MZPLJ3T2HBJR-000H3、およびMZPLJ6T4HALA-000H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZPLJ6T4HALA-000H3","target_guid":"4d2340a5-505a-4a4c-3654-3448bda98199","type":"nvme"},{"id":"MZPLJ3T2HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3354-3248fdc50136","type":"nvme"},{"id":"MZPLJ1T6HBJR-000H3","target_guid":"4d2340a5-505a-4a4c-3154-3648f52fd02c","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T04:38:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode.</li>\n\t<li>Old FW download Blocking (EPK70H3Q~EPK74H3Q).</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZPLJ6T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ1T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZPLJ3T2HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFDSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a4644534c","Version":"HPD4"},{"DeviceName":"MB4000JFDSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRNSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a4644534e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFDSL and MB4000JFDSN"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB2000JFDSL and MB4000JFDSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB2000JFDSL and MB4000JFDSN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16230274","datemodified":"2021-08-26T19:03:41","file_list":["/CP048347_BUILD_2.data","/CP048347.vmexe","/CP048347.vmexe64","/CP048347.vmfile","/CP048347_VMw.zip","/CP048347.xml","/payload.json","/CP048347_VMw.zip/index.xml","/CP048347_VMw.zip/vendor-index.xml","/CP048347_VMw.zip/metadata.zip","/CP048347_VMw.zip/vib20/CP048347/HPE_bootbank_CP048347_HPD4.2-7.0.0.15843807.vib","/CP048347_VMw.zip/metadata.zip/vendor-index.xml","/CP048347_VMw.zip/metadata.zip/vmware.xml","/CP048347_VMw.zip/metadata.zip/vibs/CP048347--2948227851561811756.xml","/CP048347_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048347_HPD4.2-7.0.0.15843807.xml"],"md5sum":"152c997edc171e0380b59f2eafa1d89c","name":"CP048347.zip","release":"2021-08-26T18:58:39","revision":"0","sha1sum":"203f2f41b88577da3c32c46c761aae81795a65cb","size":"15MB","target_guids":["002340a5-4d00-3242-3030-304a4644534c","002340a5-4d00-3442-3030-304a4644534e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048347","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"8e3928e62813480eab785be8f1d93fd8","version":"2fa0ab4d2d5342278be03969a9f45672"},"installation":{"command":"CP040513.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFDSL and MB4000JFDSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000JFDSLおよびMB4000JFDSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFDSL","target_guid":"002340a5-4d00-3242-3030-304a4644534c","type":"sas"},{"id":"MB4000JFDSN","target_guid":"002340a5-4d00-3442-3030-304a4644534e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T19:49:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFDSN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFDSL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;&nbsp;VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2921016","datemodified":"2021-07-25T19:27:07","file_list":["cp048642.xml","cpqsetup.exe","GPM853G1.rel","payload.json","setup.dll"],"md5sum":"738948c399e0dae32fc52ad5e431c59c","name":"cp048642.exe","release":"2021-07-25T19:20:04","revision":"0","sha1sum":"dfbbb8ec7a68f6acb62acc1cdd2b76f420d78b2d","size":"2MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"6f3decdb759d4bafa6df9af42f08e497","version":"64489e1f65a843c59317a9ed5167d345"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:28:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17897376","datemodified":"2022-02-21T05:09:31","file_list":["A41_2.56_02_10_2022.signed.flash","cp050797.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"c7adf2cf1472c46b1603f5bc16fe01aa","name":"cp050797.exe","release":"2022-02-21T05:07:36","revision":"0","sha1sum":"67c25ba80ae8838994070e7af2e25f8630f624fb","size":"17MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"4ecda510f4cf4aef9ac80ad782d1c36e","version":"9db55457050d47638d4df0c20d9ea25e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL325 Gen10 (A41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T06:06:21","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3526648","datemodified":"2021-07-25T15:40:30","file_list":["cp048613.xml","cpqsetup.exe","payload.json","setup.dll","SMBPETG4.rel"],"md5sum":"b1a0cde0973c2c8a425a06adca91e9f5","name":"cp048613.exe","release":"2021-07-25T15:33:06","revision":"0","sha1sum":"a31d2adb2e2af7752361956d871366449fae7f3d","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"91ee236bfbbc43019f9a1a0183e7fcbd","version":"0261662d06d5477f8804731dce23ff8d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:48:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JDXBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a44584241","Version":"HPD5"},{"DeviceName":"EH0450JDXBB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a44584242","Version":"HPD5"},{"DeviceName":"EH0600JDXBC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SXD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a44584243","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JDXBA, EH0450JDXBB and EH0600JDXBC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB&nbsp;and EH0600JDXBC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15994262","datemodified":"2021-08-30T06:36:08","file_list":["/CP048291_BUILD_2.data","/CP048291.vmexe","/CP048291.vmexe64","/CP048291.vmfile","/CP048291_VMw.zip","/CP048291.xml","/payload.json","/CP048291_VMw.zip/index.xml","/CP048291_VMw.zip/vendor-index.xml","/CP048291_VMw.zip/metadata.zip","/CP048291_VMw.zip/vib20/CP048291/HPE_bootbank_CP048291_HPD5.2-7.0.0.15843807.vib","/CP048291_VMw.zip/metadata.zip/vendor-index.xml","/CP048291_VMw.zip/metadata.zip/vmware.xml","/CP048291_VMw.zip/metadata.zip/vibs/CP048291-4490760307014992427.xml","/CP048291_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048291_HPD5.2-7.0.0.15843807.xml"],"md5sum":"7d2c5417d430635c414b0ff823ca34ce","name":"CP048291.zip","release":"2021-08-30T06:31:33","revision":"0","sha1sum":"13dd9db1478f31f1d4a0b29f4abe599669c6352f","size":"15MB","target_guids":["002340a5-4500-3048-3330-304a44584241","002340a5-4500-3048-3435-304a44584242","002340a5-4500-3048-3630-304a44584243"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048291","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"d39d0611a5e74799a9f08e5f5809ddba","version":"cb04a674a70c4c16a19cc21714c93e9c"},"installation":{"command":"CP039429.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JDXBA, EH0450JDXBB and EH0600JDXBC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JDXBA、EH0450JDXBB、およびEH0600JDXBCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JDXBA","target_guid":"002340a5-4500-3048-3330-304a44584241","type":"sas"},{"id":"EH0450JDXBB","target_guid":"002340a5-4500-3048-3435-304a44584242","type":"sas"},{"id":"EH0600JDXBC","target_guid":"002340a5-4500-3048-3630-304a44584243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T05:56:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0450JDXBB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JDXBA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0600JDXBC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Blade Intel ixt 10 Gigabit Ethernet NIC用のvxnドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"838056","datemodified":"2021-08-18T16:12:14","file_list":["cp049076.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"md5sum":"ca470ccb2befa959c31eb4376d937ecf","name":"cp049076.exe","release":"2021-08-18T15:58:21","revision":"0","sha1sum":"5f13eb20af7b137b95d50de3dc620bff11889a60","size":"818KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"type_of_change":"0","version":"2.1.191.0"}],"id":{"product":"266dae77506e4f72bfe8d5ce5b7da6ff","version":"ed31c9f0b77b455d82428d11c41b9522"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel vxn Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Intel vxnドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library vxnmsg.dll.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"vxn68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.05.03"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.05.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"11169500","datemodified":"2021-08-25T09:51:29","file_list":["/CP046821_BUILD_6.data","/CP046821.vmexe","/CP046821.vmexe64","/CP046821.vmfile","/CP046821_VMw.zip","/CP046821.xml","/payload.json","/CP046821_VMw.zip/index.xml","/CP046821_VMw.zip/vendor-index.xml","/CP046821_VMw.zip/metadata.zip","/CP046821_VMw.zip/vib20/CP046821/HPE_bootbank_CP046821_2021.10.01.6-6.7.0.7535516.vib","/CP046821_VMw.zip/metadata.zip/vendor-index.xml","/CP046821_VMw.zip/metadata.zip/vmware.xml","/CP046821_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046821_2021.10.01.6-6.7.0.7535516.xml","/CP046821_VMw.zip/metadata.zip/vibs/CP046821-8384831520799301049.xml"],"md5sum":"76404e99523ad837fe1cd9351176bf7c","name":"CP046821.zip","release":"2021-08-25T09:46:07","revision":"0","sha1sum":"714dfe411bfa8b5abf20d7394d85ac9f9b4d9f39","size":"10MB","target_guids":["a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046821","version":"2021.10.01.6-6.7.0.7535516"}]}],"id":{"product":"1c1d2de07cc24b02aa01d9c2dc7eff75","version":"f64e678084264cc4a0b2713c1fd12504"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.7"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 6.7用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p dir=\"LTR\">&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a&nbsp;behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage Fibre Channel connectivity on Linux Server for QLogic Host Bus Adapter and Mezzanine Host Bus Adapter"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2277937","datemodified":"2021-08-26T08:51:55","file_list":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ia32.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64-64bit.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"md5sum":"519489149343821d20fedf1699be527b","name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.0-16.noarch.rpm","release":"2021-08-26T08:44:16","revision":"0","sha1sum":"c47ec31206b00ee19075e7e3d1d9282adb806f83","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"type_of_change":"1","version":"6.0.0.0-16"}],"id":{"product":"d1422347af3f4f888596c242a7fdb7a6","version":"b99155014e134315927457e0b5d4b0c0"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The Enablement Kit requires that the target environment have the libHBAAPI package installed from your OS installation media.</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 12 service pack&nbsp;4 and SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;Rewrite of same Enablement kit version on SuSE Linux Enterprise Server 15 service pack&nbsp;1 and SuSE Linux Enterprise Server 15 service pack&nbsp;2 has to be performed using --reinstall option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-hpeqlgc-Enablement-Kit-&lt;version&gt;.noarch.rpm --force --nodeps</p>\n\n<p>For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter and Mezzanine Host Bus Adapter for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:51:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated the kit to version 6.0.0.0-16</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated the kit to version 6.0.0.0-16</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v1.58 (01/13/2022)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U46_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33810736","datemodified":"2022-02-07T07:37:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/CP050785.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/U46_1.58_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u46-1.58_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050785.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050785.scexe"],"md5sum":"b6c356eefbaf225f83682292171e323e","name":"firmware-system-u46-1.58_2022_01_13-1.1.x86_64.rpm","release":"2022-02-07T07:29:57","revision":"0","sha1sum":"bf38edba2ac5e09362e4c67df6ffc742e4cde539","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"4eb73551b4784537817e4ada8a1d49b5","version":"4f850dcfc3dc45f8b72856abc8099bfa"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\nコマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL360/DL380 Gen10 Plus（U46）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-14T01:15:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"U46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000JEFRB and MM2000JEFRC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17366085","datemodified":"2021-08-27T06:58:58","file_list":["/CP048391_BUILD_2.data","/CP048391.vmexe","/CP048391.vmexe64","/CP048391.vmfile","/CP048391_VMw.zip","/CP048391.xml","/payload.json","/CP048391_VMw.zip/index.xml","/CP048391_VMw.zip/vendor-index.xml","/CP048391_VMw.zip/metadata.zip","/CP048391_VMw.zip/vib20/CP048391/HPE_bootbank_CP048391_HPD9.2-7.0.0.15843807.vib","/CP048391_VMw.zip/metadata.zip/vendor-index.xml","/CP048391_VMw.zip/metadata.zip/vmware.xml","/CP048391_VMw.zip/metadata.zip/vibs/CP048391--8288305502192072914.xml","/CP048391_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048391_HPD9.2-7.0.0.15843807.xml"],"md5sum":"8d9f061fa4c837e6fa9fd0d0b76ffc68","name":"CP048391.zip","release":"2021-08-27T06:53:33","revision":"0","sha1sum":"507cf7b0622801036b658840b4deaf100c6a99be","size":"16MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048391","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"6f1e3dc0362445eba42c38fd34e5d638","version":"6d32d43ca1bf4a7c807c526131c46258"},"installation":{"command":"CP042542.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T11:40:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel igbn Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.5.2.0.</p>\n"}],"files":[{"bytes":"121871","datemodified":"2021-08-11T09:34:21","file_list":["/cp047111.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/vib20/igbn/INT_bootbank_igbn_1.5.2.0-1OEM.700.1.0.15843807.vib","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vmware.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/vibs/igbn-2757282774975846762.xml","/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807_17292660.zip/metadata.zip/bulletins/Intel-igbn_1.5.2.0-1OEM.700.1.0.15843807.xml"],"md5sum":"10fc3f2640bdcc212ec7261dcbf06252","name":"cp047111.zip","release":"2021-08-11T09:31:04","revision":"0","sha1sum":"a79b56c2863c921d34d8397ab87ac1d64bc94827","size":"119KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"igbn","version":"1.5.2.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d6816ab14fc34e169d27b5a4d2e7e7a1","version":"bd5f680cb0284f84938c9958546b8381"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel igbn Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which handling duplex value passed of ESXi command.</p>\n"},{"curr_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-igbn:1.5.2.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEQNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745514e48","Version":"HPGB"},{"DeviceName":"MB6000GEQNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPFCGB.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745514e4b","Version":"HPGB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEQNH and MB6000GEQNK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000GEQNHおよびMB6000GEQNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG7</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp;This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5615477","datemodified":"2021-07-23T07:19:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/CP048162.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/HAKPFCGB.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bfc95f0628-HPGB-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048162.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048162.scexe"],"md5sum":"efedb130e8babe3784a174c86ae62494","name":"firmware-hdd-bfc95f0628-HPGB-9.1.x86_64.rpm","release":"2021-07-23T07:07:19","revision":"0","sha1sum":"7cd6863a9460d12d70551676a7af3ed8a1e9ce5d","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304745514e48","002340a5-4d00-3642-3030-304745514e4b"],"type_of_change":"2","version":"HPGB"}],"id":{"product":"197f33c3224544b3a3519e65de72192d","version":"7e21abe85bb14fada1f6bf4dac02bb56"},"installation":{"command":"CP040269.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000GEQNH and MB6000GEQNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000GEQNHおよびMB6000GEQNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GEQNH","target_guid":"002340a5-4d00-3442-3030-304745514e48","type":"sata"},{"id":"MB6000GEQNK","target_guid":"002340a5-4d00-3642-3030-304745514e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:14:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEQNH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEQNK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for HPE Broadcom NetXtreme-E devices for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2019用HPE Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1038992","datemodified":"2021-09-28T03:39:32","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp047875.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"e2d5d050cee413ded2689e6366d028bb","name":"cp047875.exe","release":"2021-09-28T03:24:47","revision":"0","sha1sum":"b7ef971b44bc300bc6974bc0a26e9ae79330f8c2","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"219.0.44.0"}],"id":{"product":"dd64dbafe6064086a1f60841a460f8b0","version":"3b7104998a5d4d0a8238f16f4f772190"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes BSOD observed after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which System was unavailable to the create more then 32 &nbsp;Virtual Functions (VFs) per &nbsp;Virtual Functions (VFs)</li>\n\t<li>This product correct an issue which BSOD during heavy TX traffic.</li>\n\t<li>This product correct an issue which driver Initialization failure on Virtual functions</li>\n\t<li>This product correct an issue which BSOD after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which invalid link speed options on Base-T devices</li>\n\t<li>This product correct an issue which &nbsp;VF invalid on Windows virtual machines host</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.5 Fibre Channel Driver kit for HPE Storage Emulex Host Bus Adapters(HBAs)"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1472255","datemodified":"2021-08-25T10:54:18","file_list":["/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip","/cp046811.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/lpfc-12.8.317.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/README.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/doc/release_note_lpfc_12.8.317.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.317.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lpfc-12.8.317.0.xml","/VMW-ESX-6.5.0-lpfc-12.8.317.0-17062608.zip/VMW-ESX-6.5.0-lpfc-12.8.317.0-offline_bundle-17062608.zip/metadata.zip/vibs/lpfc--3610581689307200678.xml"],"md5sum":"bef690391c6378e497acf8d1ae468dfd","name":"cp046811.zip","release":"2021-08-25T10:53:32","revision":"0","sha1sum":"abbca1bfe2138c45f01716ac2f226ff45c301c24","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.317.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"8853841c6fb24cd98f983bbce280eeca","version":"252b0f1c8bb1451ebe1bdfe59838b792"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong></p>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware Vsphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>Vsphere Update Manager（VUM）およびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Fibre Channel driver component for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:31:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability</li>\n</ul>\n\n<p>Updated to Driver version 12.8.317.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.317.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.317.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JEQUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45515556","Version":"HPDB"},{"DeviceName":"MB8000JEQVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC8SDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a45515641","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JEQUV and MB8000JEQVA"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000JEQUVおよびMB8000JEQVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000JEQUV and MB8000JEQVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD9<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5513731","datemodified":"2021-07-23T07:36:18","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/CP048171.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/HAHC8SDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-df22f7effd-HPDB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048171.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048171.scexe"],"md5sum":"9d56c63e1b8a23daa308919ed70b42ad","name":"firmware-hdd-df22f7effd-HPDB-8.1.x86_64.rpm","release":"2021-07-23T07:23:07","revision":"0","sha1sum":"23a2c15c0e430e9dcd6f87edc751ff5cf60fb9ec","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a45515556","002340a5-4d00-3842-3030-304a45515641"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"9c74011372f646da931c0840d918013f","version":"e6fa796f74a54adf823551bebe089727"},"installation":{"command":"CP040350.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JEQUV and MB8000JEQVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JEQUVおよびMB8000JEQVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JEQUV","target_guid":"002340a5-4d00-3642-3030-304a45515556","type":"sas"},{"id":"MB8000JEQVA","target_guid":"002340a5-4d00-3842-3030-304a45515641","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:54:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JEQVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: MK0960GECQK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features&nbsp;:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4614956","datemodified":"2021-07-23T07:47:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/CP048178.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/GSV843G3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3e34285be7-HPG3-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048178.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048178.scexe"],"md5sum":"d91e7b1fdcb8638fdb1af454e1e9fc1f","name":"firmware-hdd-3e34285be7-HPG3-11.1.x86_64.rpm","release":"2021-07-23T07:34:17","revision":"0","sha1sum":"7b7a8ea4146adb9cabfeadf22112cf6da41657e1","size":"4MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3"}],"id":{"product":"63eaf8b9f2d74ded922cd74f7d530631","version":"c510c34f0a584917a49984e64618cb14"},"installation":{"command":"CP040262.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:20:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4445504","datemodified":"2021-07-23T18:36:31","file_list":["cp048667.xml","cpqsetup.exe","payload.json","setup.dll","TAGLXYG8.REL"],"md5sum":"d113891eda189280adaaa1a295764e86","name":"cp048667.exe","release":"2021-07-23T18:28:05","revision":"0","sha1sum":"761183bb7b7b31c0457e7fefa1948c7f12eaa743","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"15b8ab8f16cc44ddb79fc673833826dc","version":"9074efde514b44d3818b41d5f56d3190"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T07:34:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17655034","datemodified":"2021-08-30T07:39:40","file_list":["/CP048297_BUILD_2.data","/CP048297.vmexe","/CP048297.vmexe64","/CP048297.vmfile","/CP048297_VMw.zip","/CP048297.xml","/payload.json","/CP048297_VMw.zip/index.xml","/CP048297_VMw.zip/vendor-index.xml","/CP048297_VMw.zip/metadata.zip","/CP048297_VMw.zip/vib20/CP048297/HPE_bootbank_CP048297_HPD2.2-7.0.0.15843807.vib","/CP048297_VMw.zip/metadata.zip/vendor-index.xml","/CP048297_VMw.zip/metadata.zip/vmware.xml","/CP048297_VMw.zip/metadata.zip/vibs/CP048297--7520315920368581652.xml","/CP048297_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048297_HPD2.2-7.0.0.15843807.xml"],"md5sum":"747751d19d546bb3242fc23de8484b30","name":"CP048297.zip","release":"2021-08-30T07:34:50","revision":"0","sha1sum":"58e95422d68e8cfc53483c47ea41fd0492cf5bb3","size":"16MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048297","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"d54c971d2c3047569ed2e37939cd2848","version":"33fe48591db5429eaf0c825e5302057d"},"installation":{"command":"CP040645.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA および MO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T09:34:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel mezzanine host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9337293","datemodified":"2021-08-20T07:01:14","file_list":["/CP046778_BUILD_3.data","/CP046778.vmexe","/CP046778.vmexe64","/CP046778.vmfile","/CP046778_VMw.zip","/CP046778.xml","/payload.json","/CP046778_VMw.zip/index.xml","/CP046778_VMw.zip/vendor-index.xml","/CP046778_VMw.zip/metadata.zip","/CP046778_VMw.zip/vib20/CP046778/HPE_bootbank_CP046778_2021.09.01.3-7.0.0.15843807.vib","/CP046778_VMw.zip/metadata.zip/vendor-index.xml","/CP046778_VMw.zip/metadata.zip/vmware.xml","/CP046778_VMw.zip/metadata.zip/vibs/CP046778--2735679152387631576.xml","/CP046778_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046778_2021.09.01.3-7.0.0.15843807.xml"],"md5sum":"783b6cd31417cd74514a7010b145f09d","name":"CP046778.zip","release":"2021-08-20T06:56:05","revision":"0","sha1sum":"799095369063eb25cfa028d45ea64975126ef9a2","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046778","version":"2021.09.01.3-7.0.0.15843807"}]}],"id":{"product":"4168bdd100e94b7997ab17226da297b5","version":"8e09ba56beda4e2fa99aa196ed2136af"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Mezzanine Host Bus Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a behavior where the Unified Extensible Firmware Interface (UEFI) driver would force the system to reboot if one or both ports of a mezzanine adapter were not connected to an interconnect module during boot.</li>\n\t<li>Fixed a behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2213409","datemodified":"2021-02-25T10:49:53","file_list":["/cp045860.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vendor-index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vmware-storcli.vib","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vendor-index.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vmware.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/vibs/vmware-storcli--8232902898101632508.xml","/storcli-esxi6.7-bundle-007.1616.0000.0000.zip/metadata-storcli-esxi6.7-bundle-007.1616.0000.0000.zip/bulletins/HPE-esx-6.7.0-storcli-007.1616.0000.0000.xml"],"md5sum":"0030c84ede3e14d3c0bb8a3f37fba171","name":"cp045860.zip","release":"2021-02-25T10:49:04","revision":"0","sha1sum":"720ea694c1d9d931ecb20138a894b0a648f170f3","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec16a8689d"],"type_of_change":"1","version":"2021.04","vib_list":[{"name":"vmware-storcli","version":"007.1616.0000.0000-01"}]}],"id":{"product":"89a2a097a7fc4af6987e0d04ef00de6a","version":"141e6e7c72144a15a6805876d9b696b2"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7&nbsp;host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-05T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Support for maintaining, monitoring and configuring MegaRAID Gen10+ Controllers: MR416i-a, MR416i-p, MR216i-a, MR216i-p</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"vmware-storcli:007.1616.0000.0000","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"5093193","datemodified":"2021-12-08T05:45:58","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"4039b902785ff182af4cd64600bcf09a","name":"hp-ixgbe-kmp-default-5.13.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-12-08T05:36:25","revision":"0","sha1sum":"41d89da95d781acd38e035c56cfa8d349d85d864","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.13.4-1"},{"bytes":"5243555","datemodified":"2021-12-08T05:47:27","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-ixgbe","./lib/modules/5.3.18-57-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"fbc5e2895da30d36c624ffe05cb255ec","name":"hp-ixgbe-kmp-default-5.13.4_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-12-08T05:36:25","revision":"0","sha1sum":"390fd3296c6ad83edc27c1dbd3ff46df9e0fae08","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.13.4-1"}],"id":{"product":"3ab4de78da484144892d6ddcd8fd9b97","version":"b43589452bdd45d5af4cebdc450941fb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Suse Linux Enterprise Server 15 Service Pack 2</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that enable MDD(Malicious Driver Detection) when SRIOV is disabled.</li>\n\t<li>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"2066298","datemodified":"2020-09-04T07:10:49","file_list":["/cp045812.xml","/storcli-esxi6.7-bundle-1.25.16.zip","/storcli-esxi6.7-bundle-1.25.16.zip/index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip","/storcli-esxi6.7-bundle-1.25.16.zip/vmware-esx-storcli-1.25.16.vib","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vmware.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/vibs/vmware-esx-storcli-1.25.16--1295600419012277576.xml","/storcli-esxi6.7-bundle-1.25.16.zip/metadata-storcli-esxi6.7-bundle-1.25.16.zip/bulletins/HPE-esx-6.7.0-storcli-1.25.16.xml"],"md5sum":"604ebf579df2ccc883a16b8fb2a5a6a3","name":"cp045812.zip","release":"2020-09-04T07:10:05","revision":"0","sha1sum":"32b5594a2d06a2939ab03675e6c3c02209eb34b5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf774e4ad"],"type_of_change":"0","version":"2021.04.00","vib_list":[{"name":"vmware-esx-storcli-1.25.16","version":"1.25.16-01"}]}],"id":{"product":"0dff23f4576342a7a89f59feeba0f4a1","version":"4aec688aab964b72b6e3fde17aad5f93"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7&nbsp;host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong># esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong># esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-01T06:31:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Product&nbsp;Name with the OS version.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vmware-esx-storcli-1.25.16:1.25.16","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedentv, version&nbsp;3.11.16.0</li>\n\t<li>qedrntv, version&nbsp;3.11.16.0</li>\n\t<li>qedf, version&nbsp;1.3.42.50</li>\n\t<li>scsi-qedil, version 1.15.15.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>この製品には、以下のドライバーが含まれています。</p>\n\n<ul>\n\t<li>qedentv、バージョン3.11.16.0</li>\n\t<li>qedrntv、バージョン3.11.16.0</li>\n\t<li>qedf、バージョン1.3.42.50</li>\n\t<li>scsi-qedil、バージョン1.15.15.0</li>\n</ul>\n"}],"files":[{"bytes":"4297535","datemodified":"2021-08-11T13:40:33","file_list":["/cp049003.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedf/QLC_bootbank_qedf_1.3.42.50-1OEM.600.0.0.2768847.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/scsi-qedil/QLC_bootbank_scsi-qedil_1.15.15.0-1OEM.600.0.0.2494585.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.16.0-1OEM.650.0.0.4598673.vib","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vendor-index.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vmware.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/bulletins/qedentv-bundle-3.0.201.7_signed.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedrntv--5432460915364582024.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedf-403674252693421673.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/qedentv--7190238033104912737.xml","/qedentv-bundle-esx65-3.0.201.7_signed.zip/metadata.zip/vibs/scsi-qedil--2754727834483470936.xml"],"md5sum":"708e1056a56cb5247ad7edf0c33ad933","name":"cp049003.zip","release":"2021-08-11T13:37:14","revision":"0","sha1sum":"3d241af507f538f404e8658431a6e56ef5ef4f9c","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec660dedd2","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"qedrntv","version":"3.11.16.0-1OEM.650.0.0.4598673"},{"name":"qedf","version":"1.3.42.50-1OEM.600.0.0.2768847"},{"name":"scsi-qedil","version":"1.15.15.0-1OEM.600.0.0.2494585"},{"name":"qedentv","version":"3.11.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"cc4bfdeb5e654d1bb1a491db23bb09b4","version":"68228567b00648e99b331c3c0ca92a94"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-16T09:24:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue runs out of MSI-X interrupt vectors caused what Purple Screen of Death (PSOD)</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances that collection of Firmware debug data in different scenarios.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"scsi-qedil:1.15.15.0-1OEM.600.0.0.2494585","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:1.3.42.50-1OEM.600.0.0.2768847","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.11.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2019で動作しているHPE Intel i40ea 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1145896","datemodified":"2021-09-23T12:31:38","file_list":["cp047046.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"c0760488e66643b43a6f3cd9eb674a39","name":"cp047046.exe","release":"2021-09-23T12:15:49","revision":"0","sha1sum":"eaa5d91951e480d086e84e2ab6d426e094631046","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"dac1034844fb4856950db71b5b2c959d","version":"4f9f57c15ba44939875297f1c310c8f6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel i40eaドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library i40eamsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40ea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"58edf963-9038-4e01-80c5-59b770e09e25","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"UBM4_V1.24.signed.hex.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"V1.24"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10Plus UBM4 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、ProLiant Gen10Plus UBM4ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"61970","datemodified":"2022-01-18T06:06:50","file_list":["payload.json","UBM4_V1.24.signed.hex.ilo","UBM4_V1.24.xml"],"md5sum":"76f0f4a6cb742bef5a0ff6074bd4cad2","name":"UBM4_V1.24.fwpkg","release":"2022-01-18T06:03:45","revision":"0","sha1sum":"fe9c02185fb13e0c9fd1620883b7983b0034b334","size":"60KB","target_guids":["9675b54e-1c96-44c3-a7a1-901504000000"],"type_of_change":"1","version":"1.24"}],"id":{"product":"9bb04bf470484b20bec4464b241c8310","version":"bf02cd3969a04dc58a3b36a2219ced28"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10Plus UBM4 Backplane PIC Firmware"},{"lang":"ja","x_late":"ファームウェアパッケージ - Gen10Plus UBM4 Backplane PICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-07T10:37:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4PIC","sw_key_expectedpath":"firmware:ubmbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000GCWLT, MB3000GCWLU and MB4000GCWLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16820495","datemodified":"2021-08-26T18:37:45","file_list":["/CP048345_BUILD_2.data","/CP048345.vmexe","/CP048345.vmexe64","/CP048345.vmfile","/CP048345_VMw.zip","/CP048345.xml","/payload.json","/CP048345_VMw.zip/index.xml","/CP048345_VMw.zip/vendor-index.xml","/CP048345_VMw.zip/metadata.zip","/CP048345_VMw.zip/vib20/CP048345/HPE_bootbank_CP048345_HPG4.2-7.0.0.15843807.vib","/CP048345_VMw.zip/metadata.zip/vendor-index.xml","/CP048345_VMw.zip/metadata.zip/vmware.xml","/CP048345_VMw.zip/metadata.zip/vibs/CP048345-1026262613694912961.xml","/CP048345_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048345_HPG4.2-7.0.0.15843807.xml"],"md5sum":"5ba86e478b2a2d21a60f324df2069b15","name":"CP048345.zip","release":"2021-08-26T18:32:42","revision":"0","sha1sum":"6466131bcac001fd3fe4dd1634436bfa0cb3288a","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048345","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"3a074b488c7143aaa5904bb4840ab9e0","version":"b21ca4feede748b3a7db8f80e38e57bc"},"installation":{"command":"CP040507.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T17:27:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-202.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.02"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00 (C)<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00 (C)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware vSphere 6.7 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.02<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.00 (C)<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.00 (C)<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n     なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>VMware vSphere 6.7 OSのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>ベイ1〜10の場合、電源を入れ直した後、またはホットプラグ後にハードドライブが表示されない場合があります</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"14624184","datemodified":"2020-07-13T13:07:42","file_list":["/CP044325_BUILD_23.data","/CP044325.vmexe","/CP044325.vmexe64","/CP044325.vmfile","/CP044325_VMw.zip","/CP044325.xml","/payload.json","/CP044325_VMw.zip/index.xml","/CP044325_VMw.zip/vendor-index.xml","/CP044325_VMw.zip/metadata.zip","/CP044325_VMw.zip/vib20/CP044325/HPE_bootbank_CP044325_2.02.23-7.0.0.15843807.vib","/CP044325_VMw.zip/metadata.zip/vendor-index.xml","/CP044325_VMw.zip/metadata.zip/vmware.xml","/CP044325_VMw.zip/metadata.zip/vibs/CP044325--6705895898820980222.xml","/CP044325_VMw.zip/metadata.zip/bulletins/Smart-Component-CP044325_2.02.23-7.0.0.15843807.xml"],"md5sum":"072d7f44f61e9456893778301c446d40","name":"CP044325.zip","release":"2020-08-10T00:00:00","revision":"1","sha1sum":"74e892a1ad1bdfada5b93dd32216ecaf54060946","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef"],"type_of_change":"1","version":"2.02","vib_list":[{"name":"CP044325","version":"2.02.23-7.0.0.15843807"}]}],"id":{"product":"261bf666a3f24e9b933c66b3d8c0b26e","version":"ecb1ff23fcec4462a6d668e04fa56bfc"},"installation":{"command":"CP044325.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><br />\n<strong>NOTE: </strong>When using ESXi6.0 you must be at upgrade 3 or newer. The required SmartPQI driver is not present in earlier versions of the OS</p>\n\n<p><br />\n<strong>&nbsp; &nbsp; &nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at: <a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください：</strong></p>\n\n<p><br />\n<strong>注記</strong>：ESXi6.0を使用するには、アップグレード3以降である必要があります。以前のバージョンのOSには必要なSmartPQIドライバーがありません。</p>\n\n<p><br />\n<strong>      リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加しました。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください：<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>次のコマンドを使用してCPXXXXXX.vmexeが実行可能であることを確実にしてください:</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p>+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE D2500sbストレージブレード用HPE SASエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-05T03:01:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ESXi 7.0 support.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.518.0 of the Emulex Storport driver for Extended Systems which provides Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."},{"lang":"ja","x_late":"HPE Storageファイバーチャネル（FC）アダプターキットには、HPE Storage RAIDアレイをサポートするファイバーチャネルホストバスアダプター（HBA）ドライバーを提供する、バージョン12.8.518.0 のEmulex Storportドライバーfor Extended Systemが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2310552","datemodified":"2021-11-15T04:06:28","file_list":["cp049961.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-16.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"1c26d50d2f64a203a9997b69fe189d20","name":"cp049961.exe","release":"2021-11-15T04:03:05","revision":"0","sha1sum":"7222954debc17161e1c92b8f1881b9aa2943e94b","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.518.0"}],"id":{"product":"8085229a62d8443d85751340431d38d5","version":"1af031ae92db4ad88fd228941e78ef51"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>[インストール]ボタンをクリックして、インストールを開始します。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022"},{"lang":"ja","x_late":"HPE Storageファイバーチャネルアダプターキットfor x64 Emulex Storportドライバーfor Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added the following support :</p>\n\n<ul>\n\t<li>Added support for Windows 2022</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version&nbsp;12.8.518.0</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support :</p>\n\n<ul>\n\t<li>Added support for Windows 2022</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version&nbsp;12.8.518.0</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16815877","datemodified":"2022-01-26T04:46:24","file_list":["payload.json","U44_2.56_01_20_2022.signed.flash","U44_2.56_01_20_2022.xml"],"md5sum":"d6b4f7ca23257ec1f9d7df01c7428635","name":"U44_2.56_01_20_2022.fwpkg","release":"2022-01-26T04:42:42","revision":"0","sha1sum":"cf20f77d954697ff355fcfa54df26a3fc87d12dc","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"f2f901fd357f4c6692fae66dcbbb15ed","version":"426c1db7f0614c8cbf5fd80ae567d2b7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant ML30 Gen10(U44)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:51:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0240GEPQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-30474550514e","Version":"HPG1"},{"DeviceName":"VK0480GEPQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304745505150","Version":"HPG1"},{"DeviceName":"VK0960GEPQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM853G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304745505151","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;&nbsp;VK0240GEPQN, VK0480GEPQP&nbsp;and VK0960GEPQQ Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4774659","datemodified":"2021-07-23T08:58:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/CP048193.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/GPM853G1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a516522d1-HPG1-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048193.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048193.scexe"],"md5sum":"c7a129023513fa75a85d2e9a6246f888","name":"firmware-hdd-1a516522d1-HPG1-9.1.x86_64.rpm","release":"2021-07-23T08:46:11","revision":"0","sha1sum":"cb4f20432d6e103defd245a002e9c9dd064703f7","size":"4MB","target_guids":["002340a5-5600-304b-3234-30474550514e","002340a5-5600-304b-3438-304745505150","002340a5-5600-304b-3936-304745505151"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"86fd494457ed46feb0f879467158193c","version":"22cd8f79724143e6b35259888e864a83"},"installation":{"command":"CP040297.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0240GEPQN, VK0480GEPQP and VK0960GEPQQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64)- VK0240GEPQN、VK0480GEPQP、およびVK0960GEPQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK0240GEPQN","target_guid":"002340a5-5600-304b-3234-30474550514e","type":"sata"},{"id":"VK0480GEPQP","target_guid":"002340a5-5600-304b-3438-304745505150","type":"sata"},{"id":"VK0960GEPQQ","target_guid":"002340a5-5600-304b-3936-304745505151","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:34:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GEPQQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GEPQN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GEPQP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960JWSSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304a57535351","Version":"HPD8"},{"DeviceName":"VK001920JWSSR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304a57535352","Version":"HPD8"},{"DeviceName":"VK003840JWSST","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304a57535354","Version":"HPD8"},{"DeviceName":"VK007680JWSSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304a57535355","Version":"HPD8"},{"DeviceName":"VO015300JWSSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643SAMD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57535356","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000960JWSSQ、VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16795581","datemodified":"2021-08-27T13:13:59","file_list":["/CP048446_BUILD_4.data","/CP048446.vmexe","/CP048446.vmexe64","/CP048446.vmfile","/CP048446_VMw.zip","/CP048446.xml","/payload.json","/CP048446_VMw.zip/index.xml","/CP048446_VMw.zip/vendor-index.xml","/CP048446_VMw.zip/metadata.zip","/CP048446_VMw.zip/vib20/CP048446/HPE_bootbank_CP048446_HPD8.4-7.0.0.15843807.vib","/CP048446_VMw.zip/metadata.zip/vendor-index.xml","/CP048446_VMw.zip/metadata.zip/vmware.xml","/CP048446_VMw.zip/metadata.zip/vibs/CP048446-5595848961480351804.xml","/CP048446_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048446_HPD8.4-7.0.0.15843807.xml"],"md5sum":"6789b713f4da7a58dc295aa60d0eb4a2","name":"CP048446.zip","release":"2021-08-27T13:09:13","revision":"0","sha1sum":"5723a338fb4f05fa92b1fbb5d173c4562d3c6dac","size":"16MB","target_guids":["562340a5-304b-3030-3936-304a57535351","562340a5-304b-3130-3932-304a57535352","562340a5-304b-3330-3834-304a57535354","562340a5-304b-3730-3638-304a57535355","562340a5-304f-3531-3330-304a57535356"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048446","version":"HPD8.4-7.0.0.15843807"}]}],"id":{"product":"b197b25ba5a84d17992b28174218a00a","version":"4d0c314d79894a1599b4b9039e0ed937"},"installation":{"command":"CP042469.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000960JWSSQ, VK001920JWSSR, VK003840JWSST, VK007680JWSSU and VO015300JWSSV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -VK000960JWSSQ、 VK001920JWSSR、VK003840JWSST、VK007680JWSSUおよびVO015300JWSSVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWSSV","target_guid":"562340a5-304f-3531-3330-304a57535356","type":"sas"},{"id":"VK007680JWSSU","target_guid":"562340a5-304b-3730-3638-304a57535355","type":"sas"},{"id":"VK003840JWSST","target_guid":"562340a5-304b-3330-3834-304a57535354","type":"sas"},{"id":"VK001920JWSSR","target_guid":"562340a5-304b-3130-3932-304a57535352","type":"sas"},{"id":"VK000960JWSSQ","target_guid":"562340a5-304b-3030-3936-304a57535351","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T15:22:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920JWSSR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWSSV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK000960JWSSQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK003840JWSST","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK007680JWSSU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD1"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD1"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD1"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM6AFSHPD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VO003840XZCLT、VO007680XZCMB、MO000800XZCLQおよびMO001600XZCLVドライブ</p>\n\n<p><strong>リリースバージョンおよび/または日付：</strong><br />\n     HPD1<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     なし<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n      なし<br />\n<br />\n<strong>ファームウェアの依存関係：</strong><br />\n     なし  <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<ul>\n\t<li>コマンドのタイムアウトと修正不可能なエラーの改善を修正しました。</li>\n\t<li>SAS4自動電力スイッチおよびサーマル要件の機能が追加されました。</li>\n</ul>\n\n<p><strong>既知の問題点:</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"5679285","datemodified":"2021-12-13T08:50:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/CP050461.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/TAPM6AFSHPD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050461.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050461.scexe"],"md5sum":"9b1e2166dec3e24a55c63088ffb5b3ed","name":"firmware-hdd-8f501d6cf1-HPD1-1.1.x86_64.rpm","release":"2021-12-23T00:00:00","revision":"2","sha1sum":"c71548d82d726102a9a626732d87f8b3bdb0206a","size":"5MB","target_guids":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"b271ca95088c47b0b57cf56bd9562a4c","version":"0f49fd53cabb4cde8d0d4be1ae335403"},"installation":{"command":"CP041670.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>一つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール (rpm -ivh)は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成した Service Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840XZCLT","target_guid":"562340a5-304f-3330-3834-30585a434c54","type":"sas"},{"id":"MO001600XZCLV","target_guid":"4d2340a5-304f-3130-3630-30585a434c56","type":"sas"},{"id":"MO000800XZCLQ","target_guid":"4d2340a5-304f-3030-3830-30585a434c51","type":"sas"},{"id":"VO007680XZCMB","target_guid":"562340a5-304f-3730-3638-30585a434d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-25T11:03:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fix command timeout and uncorrectable error improvement.</li>\n\t<li>Added features for SAS4 auto power swtiching and thermal requirement.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840XZCLT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600XZCLV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800XZCLQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680XZCMB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5768705","datemodified":"2021-08-26T08:56:39","file_list":["./etc/depmod.d/qla2xxx.conf","./etc/udev/rules.d/99-nvme-fc.rules","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/dracut/dracut.conf.d/70-qla2xxx-nvmefc-autoconnect.conf","./usr/lib/systemd/system/qla2xxx-nvmefc-boot-connection.service","./usr/lib/systemd/system/qla2xxx-nvmefc-connect@.service","./usr/lib/udev/rules.d/70-qla2xxx-nvmefc-autoconnect.rules","./usr/sbin/qla2xxx/qla2xxx_nvme_boot_connections.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"md5sum":"904d7c00ae0810a0269cbacfdbc19542","name":"kmod-qlgc-qla2xxx-10.02.01.00.a14_k1-1.rhel7u9.x86_64.rpm","release":"2021-08-26T08:44:59","revision":"0","sha1sum":"93e201b752f2bc151820ca9792faa6c57d9ce6cf","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"6227fd0bddb244e4842587fb56f2e5ab","version":"aa2c02b27a6c464e9ee18d187a15882c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n"},{"lang":"ja","x_late":"<p>1. システム管理者 (root) としてログインします。</p>\n\n<p>2. RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3. ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n                   <br/>\n                    # rpm -Uvh kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh kmod-qla2xxx-4.6.28-20.rhel6u1.x86_64.rpm<br />\n<br />\n4. インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。  </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                      # rpm -e kmod-qla2xxx-<version>.<OSupdate>.x86_64.rpm</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:51:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Improve detection and recovery from conditions described in customer advisory available at <a href=\"http://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-qlgc-qla2xxx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1345.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12979356","datemodified":"2021-08-25T05:47:43","file_list":["/CP046753_BUILD_7.data","/CP046753.vmexe","/CP046753.vmexe64","/CP046753.vmfile","/CP046753_VMw.zip","/CP046753.xml","/payload.json","/CP046753_VMw.zip/index.xml","/CP046753_VMw.zip/vendor-index.xml","/CP046753_VMw.zip/metadata.zip","/CP046753_VMw.zip/vib20/CP046753/HPE_bootbank_CP046753_2021.10.01.7-6.5.0.4240417.vib","/CP046753_VMw.zip/metadata.zip/vendor-index.xml","/CP046753_VMw.zip/metadata.zip/vmware.xml","/CP046753_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046753_2021.10.01.7-6.5.0.4240417.xml","/CP046753_VMw.zip/metadata.zip/vibs/CP046753--7470329975098991072.xml"],"md5sum":"e96cc8bd394c5525628a4b84e39ab653","name":"CP046753.zip","release":"2021-08-25T05:42:27","revision":"0","sha1sum":"0b18fd5d7bac6f901ad17d286fb18d7acae546d4","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046753","version":"2021.10.01.7-6.5.0.4240417"}]}],"id":{"product":"4b7b12ad9577426297f04a5a3b37c6cd","version":"89a1ffa7fca8420d87b3618896f85527"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed a behavior with internal engineering data displays</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33586703","datemodified":"2022-02-07T07:51:36","file_list":["payload.json","U50_1.58_01_13_2022.signed.flash","U50_1.58_01_13_2022.xml"],"md5sum":"a55ae204e2d147f01e0be4d6a38f439e","name":"U50_1.58_01_13_2022.fwpkg","release":"2022-02-07T07:47:29","revision":"0","sha1sum":"f6a7256078ead2ab94143d30e9757dc920ed9c95","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"7fe88b20c8c948e29d704473f3133fee","version":"3585bbe1a9e244cfa5e8eecef4eb7ef2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-03T02:47:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"See the release document U50_1.58_01_13_2022 in Download Product Binaries page from Product Summary of the firmware product.","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"U50","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000JWUDB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000JWUDB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"6202885","datemodified":"2021-07-23T06:02:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/CP048144.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/HLEBHssseFD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048144.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048144.scexe"],"md5sum":"de04781928d9d50a155dfca25080738d","name":"firmware-hdd-cfd7436fcc-HPD3-2.1.x86_64.rpm","release":"2021-07-23T05:50:08","revision":"0","sha1sum":"cfaa54b806b30102e2c1ef218308dc4366e2aa6a","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304a57554442"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"6cc89934ad1740b582b096e05315f04a","version":"83d6fc0e42d84131b8383a7f30d23702"},"installation":{"command":"CP041518.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWUDBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWUDB","target_guid":"4d2340a5-3042-3431-3030-304a57554442","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:25:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWUDB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4014200","datemodified":"2021-11-04T08:49:24","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-i40e","./lib/modules/4.12.14-120-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"1464e8f1e4f7bf8cb546f549ef60c9ec","name":"hp-i40e-kmp-default-2.17.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-11-04T08:33:37","revision":"0","sha1sum":"9ca5f829c30be98a00a25a626cd1067d22708f52","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"1","version":"2.17.4-1"}],"id":{"product":"9cc198d5db9a4dc58d7191dc280dcc88","version":"f664737e7cd04dc0b61a532ce7ef39c4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel i40e 驅動程式"},{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel i40e 드라이버"},{"lang":"cn","x_late":"SUSE Linux Enterprise Server 12 x86_64版HPE Intel i40e驱动程序"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where double count in crc_error and size_error counter.</li>\n\t<li>This product addresses an issue where ethtool status triggers a warning due to invalid size on veb_tc when veb-stats was enabled.</li>\n\t<li>This product addresses an issue where the kernel error message about PF reset failed.</li>\n\t<li>This product addresses an issue where the adapter LED is not blinking via ethtool command</li>\n\t<li>This product addresses an issue where physical functions cannot synchronize tpid setting</li>\n\t<li>This product addresses an issue where Linux kernel problem (kernel Oops) when Virtual Station Interface (VSI) reset.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"4860305","datemodified":"2021-12-07T04:51:41","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/CP050185.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/TA15SEe0HPD5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050185.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050185.scexe"],"md5sum":"89f5b30cccb55a19b7b44425f89daba0","name":"firmware-hdd-852266afdf-HPD5-1.1.x86_64.rpm","release":"2021-12-07T04:37:26","revision":"0","sha1sum":"8f3e6690f6b7a75c42189d4ada154b6ed70e06b3","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"5525dd3ac4024adeb1f8ec72b9fd1236","version":"a40e2374bcb84da88fb61085a6a88a39"},"installation":{"command":"CP041561.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:52:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2019が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1607136","datemodified":"2021-08-16T16:55:26","file_list":["bepnic.dll","bepnic.rtf","cp045174.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"3093635d99a9219ff96c5c26511b7fdc","name":"cp045174.exe","release":"2021-08-16T16:41:07","revision":"0","sha1sum":"09decd257803e4a2c1a3c734597b9778e11838bd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1344.0"}],"id":{"product":"a696c5bfe8e646f9a237f7c9cfde41c1","version":"c1c8e6f9919440fbbf75f9b326be855e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"<p>This driver addresses a Windows Stop Error (BSOD) seen after Windows Event ID 67.<br />\nThis driver corrects an issue which results in a BSOD for Software Defined Data Center (SDDC).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"201476","datemodified":"2021-03-08T18:14:57","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"cb1dc8d6f457f65d09afda610476c154","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u8.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"1d57731b73fb757dec2755ec6c7e2bc79ea3f5c2","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"201471","datemodified":"2021-03-08T18:10:44","file_list":["./etc/depmod.d/hp-ixgbe.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/kmod-hp-ixgbe_bl/component.xml"],"md5sum":"06f793669170fc58805b782b3bb411e7","name":"kmod-hp-ixgbe_bl-5.9.4-1.rhel7u9.x86_64.rpm","release":"2021-03-08T18:02:06","revision":"0","sha1sum":"7a89299f595cdd2e3fe23b30825d3723930b0a7c","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec05844b56"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"571bc8d279024498916baff035cbe35c","version":"06be4bb694964643a6b2119ad4e67d30"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"5727E0D6-F37B-447D-A9E4-5A7FB0B9DC8A","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5446_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-514180897A09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory 128 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5446_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-560580897A09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory 256 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5446_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-001080897A09","Version":"1.2.0.5446"},{"DeviceName":"Intel Optane DC Persistent Memory 512 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_ekvb0_1.2.0.5446_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-8089-551580897A09","Version":"1.2.0.5446"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This firmware package provides firmware for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージは、HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のファームウェアを提供します。これは、サポート対象のオペレーティングシステムでSmart Update Manager（SUM）やRESTfulインターフェイスツール（iLOREST）などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"273651","datemodified":"2021-06-10T09:14:43","file_list":["dcpmm_01.02.00.5446.xml","fw_ekvb0_1.2.0.5446_rel.bin","payload.json"],"md5sum":"fb5ad909bf2e85d2306a047cef3a8c9e","name":"dcpmm_01.02.00.5446.fwpkg","release":"2021-06-10T09:13:05","revision":"0","sha1sum":"87c30ddd11ded4298572ee5811cea9c0500b9ac0","size":"267KB","target_guids":["805DD01C-EB5A-1E76-8089-514180897A09","805DD01C-EB5A-1E76-8089-560580897A09","805DD01C-EB5A-1E76-8089-001080897A09","805DD01C-EB5A-1E76-8089-551580897A09"],"type_of_change":"1","version":"01.02.00.5446"}],"id":{"product":"5618354fdcd14e80979abf0ff965a3f7","version":"d43979dddc034ca790555ff9d63b1b81"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the <strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>localhost OSの例：<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n\n<p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Intel Corporation"}],"name":[{"lang":"en","x_late":"Firmware package for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Servers"},{"lang":"ja","x_late":"HPE Gen10サーバー上にIntel Optane DC Persistent Memoryを搭載したHPE Persistent Memory用のファームウェアパッケージ"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-20T06:45:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product contains mainly performance improvements.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8, SUSE Linux Enterprise Server 12 and VMware ESXi 7.0.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Add VMWare ESXi 6.5 U3&nbsp;support</li>\n\t<li>Add Microsoft Windows Server 2022 support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7975580","datemodified":"2021-12-14T14:45:05","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml","./etc/bash_completion.d/mft/mft_help_to_completion.pyc","./etc/bash_completion.d/mft/mft_help_to_completion.pyo"],"md5sum":"8462f9de3294fba77ce3d9d0364885ca","name":"mft-4.18.0-106.rhel7u8.x86_64.rpm","release":"2021-12-14T14:33:05","revision":"0","sha1sum":"089c970434622296bfd186e60950cb87495d7c7a","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.18"},{"bytes":"20321","datemodified":"2021-12-14T14:46:20","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1127.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"74d3c20a6878ca7060624fcf462d256b","name":"kmod-kernel-mft-mlnx-4.18.0-1.rhel7u8.x86_64.rpm","release":"2021-12-14T14:33:05","revision":"0","sha1sum":"f8ae2e0dbbd9a8872f558a51837088b5afae694f","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"type_of_change":"1","version":"4.18"}],"id":{"product":"d626ca1e86a84798ad6a218e046f62c6","version":"85d379d86da04069b96df870fc4a36cc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1127.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.18.0-1.rhel7u8.x86_64.rpm mft-4.18.0-78.rhel7u8.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 8 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxs driver for HPE Intel ixs 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているHPE Intel ixs 10 Gigabit Ethernet NIC用のvxsドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"839264","datemodified":"2021-11-02T15:52:10","file_list":["cp047085.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"md5sum":"20f955bd5d5a5db8c0c91fa07f8c2575","name":"cp047085.exe","release":"2021-11-02T15:38:25","revision":"0","sha1sum":"8f763d29e489f5484a9eba8e0f16eb9a5230024b","size":"819KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"type_of_change":"0","version":"2.1.230.0"}],"id":{"product":"b88ebb63a68747808884160b11c000eb","version":"d8e9f95aabe842f39846754e2ca1e9b8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxs Driver for Windows Server 2019"},{"lang":"ja","x_late":"Windows Server 2019用HPE Intel vxsドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1565","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d1","type":"pci","ven":"8086"},{"dev":"1564","type":"pci","ven":"8086"},{"dev":"1565","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1565159000d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInVXS.dll and vxsmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vxs68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"564704","datemodified":"2020-12-07T07:53:16","file_list":["cp046195.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"md5sum":"fbdd0a5846ed62986144f93e8b381980","name":"cp046195.exe","release":"2020-12-07T07:49:04","revision":"0","sha1sum":"fe18e03c1e3563fdffc27bb835cae859f7c66ae7","size":"551KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"type_of_change":"1","version":"12.52.0.676"}],"id":{"product":"e0019db6f6e24588a441b6cb4e743087","version":"d466ff3ae06f4c4a9c3b432b2ae22d66"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />\nSelect &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />\nClick the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Switchtec PCIe Switch Management Driver for Windows Server 2016 and Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"4000","subdev":"4000","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-400011f84000","type":"pci","ven":"11F8"},{"dev":"4052","subdev":"4052","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-405211f84052","type":"pci","ven":"11F8"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-11-29T15:24:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Support for Apollo 6500 Gen10 Plus XL675d and XL645d</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"}],"sw_keys":[{"name":"Switchtec.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICRHPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5101549","datemodified":"2021-07-23T08:44:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/CP048231.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048231.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048231.scexe"],"md5sum":"74d211e3eec17f36654c7dfea7a56cb3","name":"firmware-hdd-92d876cfea-4ICRHPK3-3.1.x86_64.rpm","release":"2021-07-23T08:31:04","revision":"0","sha1sum":"dd86b0b4f46b89f7842ea045841376b58a3ec314","size":"4MB","target_guids":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"type_of_change":"2","version":"4ICRHPK3"}],"id":{"product":"8adb99f8960b4849ba6664217211b8d2","version":"925d00301ad6475bacbe548bc7ba4fef"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO002000KWVVC、VO004000KWVUR、MO001600KWVUU、MO003200KWVUV、およびMO006400KWVVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO002000KWVVC","target_guid":"562340a5-304f-3230-3030-304b57565643","type":"nvme"},{"id":"VO004000KWVUR","target_guid":"562340a5-304f-3430-3030-304b57565552","type":"nvme"},{"id":"MO001600KWVUU","target_guid":"4d2340a5-304f-3130-3630-304b57565555","type":"nvme"},{"id":"MO003200KWVUV","target_guid":"4d2340a5-304f-3330-3230-304b57565556","type":"nvme"},{"id":"MO006400KWVVA","target_guid":"4d2340a5-304f-3630-3430-304b57565641","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T05:58:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>\n\t<p>Added support for Intel VROC platform.</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to 4ICRHPK3 that may result in SSD failure starting at 4,700 hours of operation, neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us\" style=\"color: blue; text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00111900en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001600KWVUU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWVVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWVUR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVUV","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEQNL and MB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3669728","datemodified":"2021-07-25T14:55:06","file_list":["cp048608.xml","cpqsetup.exe","HAKPSCDB.rel","payload.json","setup.dll"],"md5sum":"bd52723a1d512feb0ff51e7d81b3cb0c","name":"cp048608.exe","release":"2021-07-25T14:48:05","revision":"0","sha1sum":"50c65aaf9ef7d36c7c8fdd6c5d3abd322b8a5258","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"b2d8d2ad18164775b6ab15fb40652791","version":"fd3e6a31e9af4032ae4b205a7e0937e9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:07:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB012000GWTFEおよびMB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; </strong>&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3050144","datemodified":"2021-07-23T11:15:10","file_list":["cp048543.xml","cpqsetup.exe","payload.json","setup.dll","TAMG07abHPG7.REL"],"md5sum":"c6fa420d5b0f1546f51f8ea61b10f1da","name":"cp048543.exe","release":"2021-07-23T11:07:05","revision":"0","sha1sum":"09db85de60a67b348e916e0b0505ea8cce3a8174","size":"2MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"3b83490f55194800be58721a957dd6a1","version":"b60b237fb24641f4bc904d405304dd1c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T11:17:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34210496","datemodified":"2022-02-21T12:51:09","file_list":["A48_2.56_02_10_2022.signed.flash","cp050506.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"074f383b38804f4a930f2d6498c657f0","name":"cp050506.exe","release":"2022-02-21T12:49:21","revision":"0","sha1sum":"80dd82cba3d52771f3072720eeaf4d2d46939750","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"3702e2a6624243b4a85fa9ca1f4c0ce2","version":"48f0100edea140a5a4efb3c794723e51"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:44:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U39_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11399299","datemodified":"2022-03-08T12:59:03","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/CP051306.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/U39_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051306.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051306.scexe"],"md5sum":"e84641e058563da031575e518c0ee5c2","name":"firmware-system-u39-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-08T12:51:04","revision":"0","sha1sum":"a08340050bb0a32e32151f905138b5e92dd4aaf2","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000021b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"25afa565c5cd4e359629eee44baf7e64","version":"ff30d96f7db14e8691569781706c0d16"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T11:18:07","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"U39","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16481856","datemodified":"2021-08-27T10:31:13","file_list":["/CP048409_BUILD_3.data","/CP048409.vmexe","/CP048409.vmexe64","/CP048409.vmfile","/CP048409_VMw.zip","/CP048409.xml","/payload.json","/CP048409_VMw.zip/index.xml","/CP048409_VMw.zip/vendor-index.xml","/CP048409_VMw.zip/metadata.zip","/CP048409_VMw.zip/vib20/CP048409/HPE_bootbank_CP048409_HPG3.3-7.0.0.15843807.vib","/CP048409_VMw.zip/metadata.zip/vendor-index.xml","/CP048409_VMw.zip/metadata.zip/vmware.xml","/CP048409_VMw.zip/metadata.zip/vibs/CP048409-201601623260805544.xml","/CP048409_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048409_HPG3.3-7.0.0.15843807.xml"],"md5sum":"ca726d93748d8902722a4d93f0022c4e","name":"CP048409.zip","release":"2021-08-27T10:25:57","revision":"0","sha1sum":"d6641a7c29af4dba34391525628d663ba2c89066","size":"15MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048409","version":"HPG3.3-7.0.0.15843807"}]}],"id":{"product":"f7ead10dcb9d4e3b81c19da679b23ce2","version":"c23b4256ca69412cb45e1aac0a24aba8"},"installation":{"command":"CP040788.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、 MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T05:27:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 4."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25666","datemodified":"2021-10-01T18:40:27","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/3ef53ff4c44296a0f4079d25b1ef1cdcf43c50","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"460dbaa433da5ee0b767e0315c49b3fb","name":"libbnxt_re-219.0.8.0-rhel8u4.x86_64.rpm","release":"2021-10-01T18:31:57","revision":"0","sha1sum":"0fe2924c002c2ab7f6be63b29d27667edf29d395","size":"25KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"1","version":"219.0.8.0"}],"id":{"product":"1a80c86e194a42b7a0d5a430eb281afa","version":"465298208f764098be95d12652a65b0f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 4."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-11-01T07:34:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"186076","datemodified":"2021-11-03T12:05:54","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/51e24bf3444def984920ac38cac66ddb68881a","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"54c3e3fc6399bbf0b4fcda002540c3b1","name":"kmod-hp-ixgbe-5.13.4-1.rhel8u4.x86_64.rpm","release":"2021-11-03T11:57:51","revision":"0","sha1sum":"d398badb60222bf803b4bbd2c6ce8fe1d3695602","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.13.4-1"},{"bytes":"186259","datemodified":"2021-11-03T12:07:04","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/42","./usr/lib/.build-id/42/f8412ff098771410334d1c751f39aa81e999a9","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"de104480a78c721296c87c0802972539","name":"kmod-hp-ixgbe-5.13.4-1.rhel8u3.x86_64.rpm","release":"2021-11-03T11:57:51","revision":"0","sha1sum":"7c83398b5bb8e698e34eb7ea6c1e82a72050cdd9","size":"181KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.13.4-1"}],"id":{"product":"760adb908c054b5b910c54e6c4a5f9e4","version":"7e89ef324f6f441dbb8fb66e45d1f438"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that enable MDD(Malicious Driver Detection) when SRIOV is disabled.</li>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 4</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.05.03"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.05.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバスアダプターのファームウェアをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"3582454","datemodified":"2021-08-31T07:27:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/CP046940.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/bk017507.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/mh020503.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2021.10.01-1.10/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046940.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046940.scexe"],"md5sum":"f04f63e328be782209e6a4ea3e1580f1","name":"firmware-fc-qlogic-2021.10.01-1.10.x86_64.rpm","release":"2021-08-31T07:12:37","revision":"0","sha1sum":"dee45c0294feb4de26c067a2efaabe132462af79","size":"3MB","target_guids":["a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"bca5397d7ba147ddbb0eb4fee4d4d567","version":"c3b49c5d02c84265baf145e3733bd99b"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター用HPEファームウェアフラッシュ - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-23T07:53:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p dir=\"LTR\">&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a&nbsp;behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"610272","datemodified":"2021-12-21T07:24:42","file_list":["cp050605.xml","cpqsetup.exe","installer.dll","pnp/","pnp/NULL_HECI.cat","pnp/NULL_HECISystem.inf","pnp/RocketLake.cat","pnp/RocketLakeSystem.inf","pnp/TigerLakePCH-H.cat","pnp/TigerLakePCH-HSystem.inf"],"md5sum":"5adfcd545bb37804a9078d20e0e1bae0","name":"cp050605.exe","release":"2021-12-21T07:23:14","revision":"0","sha1sum":"3c720a67fd5dbd5170e99d6f9061785f5d059856","size":"595KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"id":{"product":"0f3487315f10473a903e3c353d754526","version":"1ff7503d6ca745bf9ff6e1ec20937e3c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows"},{"lang":"ja","x_late":"Microsoft Windows用インテルXeon E-23xxプロセッサーの識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-21T07:10:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed version control issues</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 6.7"},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel i40enアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.13.1.0.</p>\n"}],"files":[{"bytes":"226776","datemodified":"2021-11-03T07:38:45","file_list":["/cp047109.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/index.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/vendor-index.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/metadata.zip","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/vib20/i40en/INT_bootbank_i40en_1.14.3.0-1OEM.670.0.0.8169922.vib","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/metadata.zip/vendor-index.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/metadata.zip/vmware.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/metadata.zip/vibs/i40en-4871163267729902508.xml","/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922-offline_bundle-18701020.zip/metadata.zip/bulletins/Intel-i40en_1.14.3.0-1OEM.670.0.0.8169922.xml"],"md5sum":"694852544b80a483239a508cb7f3609b","name":"cp047109.zip","release":"2021-11-03T07:34:26","revision":"0","sha1sum":"bc532e88f0b9d80c64abc0ee610c5a1a8ddc9482","size":"221KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"i40en","version":"1.14.3.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"cbfe1835cecf43e391be405d2fc118ca","version":"3b4ce472549e48d18c01db01ed8bee1a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel i40enドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL360 Gen10 Plus Server</li>\n\t<li>HPE ProLiant DL380 Gen10 Plus Server&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue where PSOD when drivers loading.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"i40en:1.14.3.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"QLogic driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"QLogicドライバーfor VMware vSphere 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"817942","datemodified":"2021-08-26T11:03:18","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp046818.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"45ac3798f726f82f0aa180d7df44afa0","name":"cp046818.zip","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"0ddbcc493eb470450460fa6b35593f0d84d05584","size":"798KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"0a5c3792d04d4b22a3b657bedf5eaefc","version":"dfc089a4b3df41b4b2e7957bcc088507"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Fibre Channel driver component for VMware vSphere 6.7"},{"lang":"ja","x_late":"VMware vSphere 6.7用HPE QLogicファイバーチャネルドライバーコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-26T05:24:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"}],"files":[{"bytes":"9399117","datemodified":"2021-07-25T12:32:01","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/CP048237.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/GP173500HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-95b6ae2e85-HPK5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048237.scexe"],"md5sum":"3ecc95fc9b42ab3cc8002b9825d3e790","name":"firmware-hdd-95b6ae2e85-HPK5-4.1.x86_64.rpm","release":"2021-07-25T12:19:04","revision":"0","sha1sum":"581e5d863c987c7c514fa9165f666ff2f833d919","size":"8MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"5cda8f412fa0418489dbcbbf3f49c1b5","version":"7a8cc9a96dbb49588e8c8e4b0e20c09f"},"installation":{"command":"CP041864.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T07:40:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWSSC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757535343","Version":"HPG3"},{"DeviceName":"MK000960GWSSD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757535344","Version":"HPG3"},{"DeviceName":"MK001920GWSSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757535345","Version":"HPG3"},{"DeviceName":"MK003840GWSSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSM883G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757535346","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fix</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19075094","datemodified":"2021-08-27T12:10:49","file_list":["/CP048432_BUILD_2.data","/CP048432.vmexe","/CP048432.vmexe64","/CP048432.vmfile","/CP048432_VMw.zip","/CP048432.xml","/payload.json","/CP048432_VMw.zip/index.xml","/CP048432_VMw.zip/vendor-index.xml","/CP048432_VMw.zip/metadata.zip","/CP048432_VMw.zip/vib20/CP048432/HPE_bootbank_CP048432_HPG3.2-7.0.0.15843807.vib","/CP048432_VMw.zip/metadata.zip/vendor-index.xml","/CP048432_VMw.zip/metadata.zip/vmware.xml","/CP048432_VMw.zip/metadata.zip/vibs/CP048432-8039686905645691817.xml","/CP048432_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048432_HPG3.2-7.0.0.15843807.xml"],"md5sum":"6b414b59c23ea62824b066f7de630a23","name":"CP048432.zip","release":"2021-08-27T12:05:40","revision":"0","sha1sum":"bcea0f3528c29cbc7c0946b2bfe5d441a27b22d6","size":"18MB","target_guids":["4d2340a5-304b-3030-3438-304757535343","4d2340a5-304b-3030-3936-304757535344","4d2340a5-304b-3130-3932-304757535345","4d2340a5-304b-3330-3834-304757535346"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048432","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"4025ccc149b544568897af8cffe102f9","version":"48b30da6303f4a8888532d316cd63180"},"installation":{"command":"CP041677.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWSSC, MK000960GWSSD, MK001920GWSSE and MK003840GWSSF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MK000480GWSSC、MK000960GWSSD、MK001920GWSSE、およびMK003840GWSSFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK003840GWSSF","target_guid":"4d2340a5-304b-3330-3834-304757535346","type":"sata"},{"id":"MK001920GWSSE","target_guid":"4d2340a5-304b-3130-3932-304757535345","type":"sata"},{"id":"MK000960GWSSD","target_guid":"4d2340a5-304b-3030-3936-304757535344","type":"sata"},{"id":"MK000480GWSSC","target_guid":"4d2340a5-304b-3030-3438-304757535343","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:28:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWSSE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWSSC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWSSD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWSSF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"17488101","datemodified":"2021-08-30T05:36:02","file_list":["/CP048265_BUILD_2.data","/CP048265.vmexe","/CP048265.vmexe64","/CP048265.vmfile","/CP048265_VMw.zip","/CP048265.xml","/payload.json","/CP048265_VMw.zip/index.xml","/CP048265_VMw.zip/vendor-index.xml","/CP048265_VMw.zip/metadata.zip","/CP048265_VMw.zip/vib20/CP048265/HPE_bootbank_CP048265_HPD6.2-7.0.0.15843807.vib","/CP048265_VMw.zip/metadata.zip/vendor-index.xml","/CP048265_VMw.zip/metadata.zip/vmware.xml","/CP048265_VMw.zip/metadata.zip/vibs/CP048265--8153221444251177629.xml","/CP048265_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048265_HPD6.2-7.0.0.15843807.xml"],"md5sum":"d4e9fc156e029a957fad55e0a6bfd1d4","name":"CP048265.zip","release":"2021-08-30T05:31:38","revision":"0","sha1sum":"90ddb569ebb9a66eeb3bf237bc0ea311a9a466cb","size":"16MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048265","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"4d6b330d7f1d4462bea2b4b6ff4f5e4a","version":"a5425ea17fb043f6a196aaa90090983d"},"installation":{"command":"CP040624.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T11:52:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."},{"lang":"ja","x_late":"このコンポーネントは、プロセッサーとチップセット内のデバイスを識別するためのドライブなしのINFsを実装します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"621584","datemodified":"2021-12-21T05:34:56","file_list":["cp050590.xml","cpqsetup.exe","installer.dll","pnp/","pnp/IceLakeX.cat","pnp/IceLakeXSystem.inf","pnp/IceLakeXSystemNorthpeak.inf","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Server_Common.cat","pnp/Server_CommonSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"md5sum":"73ea6fdf4237ddccbbd91ba011a38c4a","name":"cp050590.exe","release":"2021-12-21T05:33:01","revision":"0","sha1sum":"dca5702b04a6cb3977ad8f56916c5434d42d93d0","size":"607KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"id":{"product":"957b79699cf847b3bc804b96d1108938","version":"b33ff401940e4309b37b0e9eaf340287"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":3600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>インストールボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows"},{"lang":"ja","x_late":"Microsoft Windows用インテルXeonスケーラブルプロセッサー（第3世代）識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-21T05:06:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Modified install time</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixed version control issues</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H10","value":"HPE Edgeline e920t Server"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000GFJTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVGNTG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-3047464a5445","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MM1000GFJTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive</p>\n\n<p><strong><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG5<br />\n<br />\n<strong><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17291449","datemodified":"2021-08-27T06:39:37","file_list":["/CP048389_BUILD_2.data","/CP048389.vmexe","/CP048389.vmexe64","/CP048389.vmfile","/CP048389_VMw.zip","/CP048389.xml","/payload.json","/CP048389_VMw.zip/index.xml","/CP048389_VMw.zip/vendor-index.xml","/CP048389_VMw.zip/metadata.zip","/CP048389_VMw.zip/vib20/CP048389/HPE_bootbank_CP048389_HPG5.2-7.0.0.15843807.vib","/CP048389_VMw.zip/metadata.zip/vendor-index.xml","/CP048389_VMw.zip/metadata.zip/vmware.xml","/CP048389_VMw.zip/metadata.zip/vibs/CP048389--6864932891830580306.xml","/CP048389_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048389_HPG5.2-7.0.0.15843807.xml"],"md5sum":"91119dfc89b4159dae8b8b13aa22056d","name":"CP048389.zip","release":"2021-08-27T06:34:14","revision":"0","sha1sum":"effabef264af177d5626a8d4bf5532c49e5e86a8","size":"16MB","target_guids":["002340a5-4d00-314d-3030-3047464a5445"],"type_of_change":"0","version":"HPG5","vib_list":[{"name":"CP048389","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"c0403221bbc14b609f9dc339f216be5e","version":"111de53e2a9842f58c6e4e37d2e2f5ab"},"installation":{"command":"CP041026.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MM1000GFJTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MM1000GFJTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MM1000GFJTE","target_guid":"002340a5-4d00-314d-3030-3047464a5445","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:44:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM1000GFJTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWBHR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEnD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57424852","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG000300JWBHR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;EG000300JWBHR&nbsp;Drive<br />\n&nbsp;</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp; &nbsp; &nbsp;&nbsp;Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Prolems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3031296","datemodified":"2021-07-24T07:58:29","file_list":["cp048436.xml","cpqsetup.exe","payload.json","setup.dll","T14SEnD5.rel"],"md5sum":"7a344468c12bc6fc2b2fc83e227d26e0","name":"cp048436.exe","release":"2021-07-24T07:51:08","revision":"0","sha1sum":"01c002ad28c9279e32fac2dc9f4f69a8cdb50e78","size":"2MB","target_guids":["452340a5-3047-3030-3330-304a57424852"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"a893ea1028be45a18d3b23d1c1c00c64","version":"852b12a0bf064f4589dcfc2fac261a62"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWBHR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG000300JWBHRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG000300JWBHR","target_guid":"452340a5-3047-3030-3330-304a57424852","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T10:59:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWBHR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P824i-p MR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MR_FW_3324_4MB.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-00cf1590022c","Version":"24.23.0-0043"}]},"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following storage controllers: HPE Smart Array P824i-p MR Gen10"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のストレージコントローラーのファームウェアを提供します。HPE SmartアレイP824i-p MR Gen10"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong><strong>:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) -&nbsp;HPE&nbsp;Smart Array P824i-p MR Gen10<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0043(A)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp; 24.23.0-0042<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for the Apollo 4510 system</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p><strong>Known&nbsp;Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"11162704","datemodified":"2020-07-17T06:48:25","file_list":["cp044919.xml","cpqsetup.exe","flash_Ctrl_1.00.bat","InstallDLL.dll","MR_FW_3324_16MB.rom","MR_FW_3324_32MB.rom","MR_FW_3324_4MB.rom","payload.json","storcli64.exe"],"md5sum":"0382af19228880baa2c1b0fee9e5475a","name":"cp044919.exe","release":"2020-07-17T06:45:04","revision":"0","sha1sum":"a316864043921bc317193b44271b793a444f9b0a","size":"10MB","target_guids":["a6b1a447-382a-5a4f-1000-00cf1590022c"],"type_of_change":"1","version":"24.23.0-0043"}],"id":{"product":"c4098b5f60c74084bd367e95f9010c52","version":"70ef2cf304f84ee5bf3810e0fed98cd5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hp.com/go/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P824i-p MR Gen10"},{"lang":"ja","x_late":"オンラインROM Flashコンポーネント for Windows (x64) - HPE SmartアレイP824i-p MR Gen10"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-08-16T13:43:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixes Firmware&nbsp;downgrade issue</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Over-temp issue was a false IML due to a &gt;=60C threshold, modified the threshold to &gt;65C in new version.</p>\n\n<p>Please reference Customer Advisory <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00101958en_us\" style=\"color:#0563c1; text-decoration:underline\">a00101958en_us</a></p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"022C1590","sw_key_expectedpath":"firmware:sd:"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK, and MO3200JFFCL Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MO0400JFFCF、MO0800JFFCH、MO1600JFFCKおよびMO3200JFFCLドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5060987","datemodified":"2021-07-23T09:39:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/CP048209.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/GP1635D9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-edf6dcd906-HPD9-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048209.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048209.scexe"],"md5sum":"e2ffbf5fb4055b5c57343d6d0f667bac","name":"firmware-hdd-edf6dcd906-HPD9-4.1.x86_64.rpm","release":"2021-07-23T09:26:08","revision":"0","sha1sum":"54f903d0803e96e389759959f9fdaeddf18c4afe","size":"4MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"436670aad3944dd794f4bdcf4feb2b72","version":"9ee85ca102644cdd846ac6f6e433ed42"},"installation":{"command":"CP042217.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MO0400JFFCF、 MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"},{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:48:38","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SATA drive models: XP0120GFJSL and XP0240GFJSN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSATAドライブモデルのファームウェアを提供します。XP0120GFJSLおよびXP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - &nbsp;XP0120GFJSL and XP0240GFJSN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5449171","datemodified":"2021-07-23T09:13:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/ASAXHPS4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/CP048198.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d355375539-HPS4-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048198.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048198.scexe"],"md5sum":"be2619f0c43e74eaccd44691cdcaf4d1","name":"firmware-hdd-d355375539-HPS4-10.1.x86_64.rpm","release":"2021-07-23T09:00:10","revision":"0","sha1sum":"a1da50a9e07e341b84c26c6ca1fa8d16c3a25f0e","size":"5MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"426a1761f14e4ba492f138726a8bcbf6","version":"1c94f0fbf9fc4304b373f502fd5c1f3b"},"installation":{"command":"CP040296.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:59:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS35, provides Windows 64-bit support for HPE MR416i-p MR416i-a MR216i-p MR216i-a controller"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"857672","datemodified":"2022-01-20T17:18:42","file_list":["cp050771.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"md5sum":"16bc755d05b28028523bb1ecc2034735","name":"cp050771.exe","release":"2022-01-20T17:16:37","revision":"0","sha1sum":"1b2560562560f23f34e3a0722ce615011f4aedbb","size":"837KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.719.6.0"}],"id":{"product":"bc97d9781e754cabbad3faa72748c1c6","version":"be2eb40e05734a22a11a2a0ae4cf300e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p MR416i-a MR216i-p MR216i-a  64-bit controller driver for Microsoft Windows 2022 edition."}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-11T07:16:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"MegaSas35.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2netドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"104097","datemodified":"2021-01-14T07:28:07","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net","./lib/modules/4.18.0-240.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"c65312308995a9987c35456d7e66344c","name":"kmod-be2net-12.0.1342.0-1.rhel8u3.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"e78856c4655f4915586cb652ef7ba358d9933549","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"104185","datemodified":"2021-01-14T07:31:41","file_list":["./etc/depmod.d/be2net.conf","./lib/modules/4.18.0-193.el8.x86_64","./lib/modules/4.18.0-193.el8.x86_64/extra","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net","./lib/modules/4.18.0-193.el8.x86_64/extra/be2net/be2net.ko","./usr/share/smartupdate/kmod-be2net/component.xml"],"md5sum":"6ac2fcd892c5adf66e0a4f8489147939","name":"kmod-be2net-12.0.1342.0-1.rhel8u2.x86_64.rpm","release":"2021-01-14T07:19:04","revision":"0","sha1sum":"895872217e5fe34b6726e35585615ab5316c88a2","size":"101KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6bd37e40"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7ac9bd0dae24b7e9605737bb695f64d","version":"6b10913d6c864a6592e3e10c90e4fb35"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Emulex 10/20GbEドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports Red Hat Enterprise Linux 8 Update 2 and&nbsp;Red Hat Enterprise Linux 8 Update 3</li>\n\t<li>This product now supports elx_net_install.sh installation script to install be2net driver on Red Hat Enterprise Linux 8 Update 1 or later.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2net","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3806464","datemodified":"2021-07-25T16:11:55","file_list":["cp048619.xml","cpqsetup.exe","payload.json","setup.dll","SMKRPSD7.rel"],"md5sum":"59420dcec9ba31208d59139a3c28c3e3","name":"cp048619.exe","release":"2021-07-25T16:03:08","revision":"0","sha1sum":"c717c10a7d6431938c8d00f3a936358058bec0ba","size":"3MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"b23cbcef087a471c988db0eccfc20ffd","version":"b97feeb703714eca9e8af78cd1f5f0f5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:38:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ  and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"19634266","datemodified":"2021-08-30T06:26:55","file_list":["/CP049272_BUILD_1.data","/CP049272.vmexe","/CP049272.vmexe64","/CP049272.vmfile","/CP049272_VMw.zip","/CP049272.xml","/payload.json","/CP049272_VMw.zip/index.xml","/CP049272_VMw.zip/vendor-index.xml","/CP049272_VMw.zip/metadata.zip","/CP049272_VMw.zip/vib20/CP049272/HPE_bootbank_CP049272_HPG2.1-7.0.0.15843807.vib","/CP049272_VMw.zip/metadata.zip/vendor-index.xml","/CP049272_VMw.zip/metadata.zip/vmware.xml","/CP049272_VMw.zip/metadata.zip/vibs/CP049272-4756568632553938442.xml","/CP049272_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049272_HPG2.1-7.0.0.15843807.xml"],"md5sum":"fdfce6a19e5f310aa81a571aed1c55b4","name":"CP049272.zip","release":"2021-08-30T06:22:32","revision":"0","sha1sum":"e4405f30fa8b58dce456a91b1cfbbca7e40bd034","size":"18MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP049272","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"966974f2ab9a4657a90227f18e4fbb1c","version":"57123cae240648b581d7f19985a087d2"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ  and VK007680GXCGR Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T13:53:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-872723-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-872725-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"20391784","datemodified":"2022-02-02T12:59:20","file_list":["cp050409.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX5-rel-16_32_1010-872723-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","fw-ConnectX5-rel-16_32_1010-872725-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"d1b0cf61f07b3f1fef2408e5e495b211","name":"cp050409.exe","release":"2022-02-02T12:57:07","revision":"0","sha1sum":"b2a8c2cbc1e1ae6a072796aae82764138ca3cb94","size":"19MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.0.9"}],"id":{"product":"d626b04e2b74450287a682c2c77ab027","version":"75277b9b4c114021aafeb00c7a723965"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T05:04:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p style=\"margin-left:40px\">843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n&nbsp;</p>\n\n<ul>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li>\n\t<li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed an&nbsp;issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33812467","datemodified":"2022-02-21T12:54:30","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/A47_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/CP050505.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050505.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050505.scexe"],"md5sum":"15fb03087df3bedc1e750eb2ecea91f0","name":"firmware-system-a47-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T12:48:05","revision":"0","sha1sum":"1eede0d14267fd4c934a50f182dcf7e915b90229","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"4a7391c65f0b46d485ea7105b1cfb339","version":"e48af4f2fbe14f7fa03e5c031924544a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:43:04","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® Gen10+ controller products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID® Gen10+コントローラー製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"2917528","datemodified":"2022-01-05T10:20:52","file_list":["cp050701.xml","cpqsetup.exe","install.xml","multisetup.dll","StorCLI.msi"],"md5sum":"0ef6ac020c5b852987017e9a642fc58f","name":"cp050701.exe","release":"2022-01-05T10:18:20","revision":"0","sha1sum":"0cceef0a38d67c18ebdd3160f3212f4d869ecd3c","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"type_of_change":"1","version":"7.16.16.0"}],"id":{"product":"a215c8b0f11b453cbd6a752733ae590e","version":"8565def15ff34002be47ffe90dd1163b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To run&nbsp;Storcli utility&nbsp;from Windows operating system on target server:</strong></p>\n\n<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation. The utility will automatically be installed.</p>\n\n<p>When the installation is complete,&nbsp;run command prompt environment and navigate to %programfiles%\\MR Storage Administrator\\StorCLI\\bin&nbsp;folder and execute Storcli64.exe utility</p>\n\n<p>For e.g: <strong>Storcli64.exe /c0 show </strong></p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバーのWindowsオペレーティングシステムからStorcliユーティリティを実行するには：</strong></p>\n\n<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。ユーティリティは自動的にインストールされます。</p>\n\n<p>インストールが完了したら、コマンドプロンプト環境を実行し、%programfiles%\\MR Storage Administrator\\StorCLI\\binフォルダーに移動し、Storcli64.exeユーティリティを実行します</p>\n\n<p>例：<strong>Storcli64.exe /c0 show </strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"},{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-05T06:13:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Support&nbsp;Microsoft Windows Server 2022</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"storcli64.exe","sw_key_expectedpath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8775096","datemodified":"2022-01-26T05:21:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/CP050867.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/U43_2.56_01_20_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-2.56_2022_01_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050867.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050867.scexe"],"md5sum":"1acfe9b2da0853ed2c91031bfd200d2b","name":"firmware-system-u43-2.56_2022_01_20-1.1.x86_64.rpm","release":"2022-01-26T05:14:28","revision":"0","sha1sum":"2260491d423796193cead168f73c4694029a9eb7","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"d3e8a053234f49d9a3735931f34c77c7","version":"aaea74bcd70044818f7e3ea7125ac448"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:23:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.05.03"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.05.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"11748121","datemodified":"2021-08-20T06:10:42","file_list":["/CP046822_BUILD_14.data","/CP046822.vmexe","/CP046822.vmexe64","/CP046822.vmfile","/CP046822_VMw.zip","/CP046822.xml","/payload.json","/CP046822_VMw.zip/index.xml","/CP046822_VMw.zip/vendor-index.xml","/CP046822_VMw.zip/metadata.zip","/CP046822_VMw.zip/vib20/CP046822/HPE_bootbank_CP046822_2021.10.01.14-7.0.0.15843807.vib","/CP046822_VMw.zip/metadata.zip/vendor-index.xml","/CP046822_VMw.zip/metadata.zip/vmware.xml","/CP046822_VMw.zip/metadata.zip/vibs/CP046822--8335643840512796465.xml","/CP046822_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046822_2021.10.01.14-7.0.0.15843807.xml"],"md5sum":"9e02015cda70bee24fcf6d5a68fcd14c","name":"CP046822.zip","release":"2021-08-20T06:05:05","revision":"0","sha1sum":"d428b0f15d7f95ca2750ffb50958e6455439f97a","size":"11MB","target_guids":["a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046822","version":"2021.10.01.14-7.0.0.15843807"}]}],"id":{"product":"5f15a26843724cddbeb0234b8805431e","version":"06a1ddf2be744538b4b8752456d848c4"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p dir=\"LTR\">&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a&nbsp;behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2518520","datemodified":"2021-08-27T04:45:09","file_list":["QLAFWUpdate.exe","adapters.properties","cp046780.xml","cpqsetup.exe","hld60404.bin","installer.dll","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"a0fd22131150e9294349a39082c3fb74","name":"cp046780.exe","release":"2021-08-27T04:31:13","revision":"0","sha1sum":"f56d0748a1d2dfeb0e6cd8cac89ca0c25d123f4c","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"775df1f4997747b1b9988fc3c9990436","version":"94cfcf3d02704a1ea00a835da15d3468"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Microsoft Windows Server 2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a behavior where the Unified Extensible Firmware Interface (UEFI) driver would force the system to reboot if one or both ports of a mezzanine adapter were not connected to an interconnect module during boot.</li>\n\t<li>Fixed a behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO007680JWCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57434e4b","Version":"HPD8"},{"DeviceName":"VO015300JWCNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"G1633HD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3330-304a57434e4c","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO007680JWCNK and VO015300JWCNL"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO007680JWCNKおよびVO015300JWCNL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO007680JWCNK and VO015300JWCNL&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16980990","datemodified":"2021-08-27T10:56:34","file_list":["/CP048415_BUILD_3.data","/CP048415.vmexe","/CP048415.vmexe64","/CP048415.vmfile","/CP048415_VMw.zip","/CP048415.xml","/payload.json","/CP048415_VMw.zip/index.xml","/CP048415_VMw.zip/vendor-index.xml","/CP048415_VMw.zip/metadata.zip","/CP048415_VMw.zip/vib20/CP048415/HPE_bootbank_CP048415_HPD8.3-7.0.0.15843807.vib","/CP048415_VMw.zip/metadata.zip/vendor-index.xml","/CP048415_VMw.zip/metadata.zip/vmware.xml","/CP048415_VMw.zip/metadata.zip/vibs/CP048415--1852356481861341247.xml","/CP048415_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048415_HPD8.3-7.0.0.15843807.xml"],"md5sum":"d7f759a3c3de9d9197c1a6bcb29e1640","name":"CP048415.zip","release":"2021-08-27T10:51:43","revision":"0","sha1sum":"805a8a018b087473ed649622a2bd4499c89c49d4","size":"16MB","target_guids":["562340a5-304f-3730-3638-304a57434e4b","562340a5-304f-3531-3330-304a57434e4c"],"type_of_change":"2","version":"HPD8","vib_list":[{"name":"CP048415","version":"HPD8.3-7.0.0.15843807"}]}],"id":{"product":"e4b6ca2c49674535912553cede176d16","version":"99a92c6e4802423b931489959d31208d"},"installation":{"command":"CP042626.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO007680JWCNK and VO015300JWCNL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VO007680JWCNKおよびVO015300JWCNLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015300JWCNL","target_guid":"562340a5-304f-3531-3330-304a57434e4c","type":"sas"},{"id":"VO007680JWCNK","target_guid":"562340a5-304f-3730-3638-304a57434e4b","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T11:19:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD8 that results in SSD failure at 32,768 hours of operation (i.e., 3 years, 270 days 8 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00092491en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680JWCNK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO015300JWCNL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"20313","datemodified":"2021-12-14T14:54:19","file_list":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"md5sum":"2b0e9382a3398f3873c8b6c67db5e814","name":"kmod-kernel-mft-mlnx-4.18.0-1.rhel7u9.x86_64.rpm","release":"2021-12-14T14:44:04","revision":"0","sha1sum":"40f50646b7a96a34bd94d278e3165adbffd9ffec","size":"19KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"},{"bytes":"7975585","datemodified":"2021-12-14T14:51:46","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml","./etc/bash_completion.d/mft/mft_help_to_completion.pyc","./etc/bash_completion.d/mft/mft_help_to_completion.pyo"],"md5sum":"3e4a32002d57627cc274b0c04e158bb3","name":"mft-4.18.0-106.rhel7u9.x86_64.rpm","release":"2021-12-14T14:44:04","revision":"0","sha1sum":"321561b38aaf22fba457fa1a1b5736484354dc52","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"}],"id":{"product":"7cbddfc3ba97405ea0a71d3635caace8","version":"bb6bffbfcd914ad8aa51cb971563f76a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh kmod-kernel-mft-mlnx-4.18.0-1.rhel7u9.x86_64.rpm&nbsp;&nbsp;mft-4.18.0-78.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kmod-kernel-mft-mlnx","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel E1R Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1071448","datemodified":"2022-01-25T07:29:35","file_list":["cp049621.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"8e377eeec6b55ba7427f051e1018c143","name":"cp049621.exe","release":"2022-01-25T07:15:09","revision":"0","sha1sum":"9db4b5e782834eeebc819e372288c99f68a51430","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"type_of_change":"1","version":"13.0.9.0"}],"id":{"product":"b5747db463a34c8c8ef853b408ae6b5c","version":"0af5d002da2144cda96d47a404629a6a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel E1R Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"e1r.sys","sw_key_expectedpath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the drivers for HPE Intel i40ea 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1166472","datemodified":"2022-01-25T07:37:50","file_list":["cp049616.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"49ee13c91ebe2a6b566f1854b7f54070","name":"cp049616.exe","release":"2022-01-25T07:23:05","revision":"0","sha1sum":"e5b583fb47f8962860a795d3a484a2f2b0638d73","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"type_of_change":"1","version":"1.16.139.0"}],"id":{"product":"8f4fd902230c4076905c23b7ab80bfdf","version":"af61de893f3c45af99eaa18baf301c8d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40ea Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"103C","target_guid":"","type":"pci","ven":"8086"},{"dev":"158A","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40ea.sys","sw_key_expectedpath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1319376","datemodified":"2021-01-09T08:26:15","file_list":["cp045010.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"31bcca242202a17fd50097031e7add33","name":"cp045010.exe","release":"2021-01-09T08:07:04","revision":"0","sha1sum":"a1b7f2d4d3011e847a7c50e583dac81478da4469","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"e774fea9b642407a9f2687df296d352e","version":"8dd3d9b9dea24c70998a024a2d8c2510"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iavf68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050806.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2912928","datemodified":"2022-02-25T01:33:54","file_list":["cp050806.compsig","cp050806.zip","cp051223.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"7a72974434786aeda444f21124e28f22","name":"cp051223.exe","release":"2022-02-25T01:32:43","revision":"0","sha1sum":"d6846d712d2de1b31c55c8e0d2d97d332e186765","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"fb9faa50a5034cfe8c3861f763b25770","version":"39e18f5d2c1f434ead54aa21c523d08e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download cp047662.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cp047662.exe.&nbsp;<br />\n2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>Execute the file &nbsp;cp047662.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant ML30 Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-24T01:20:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 06.00.03.039(B) contains updates to the firmware packaging and is functionally equivalent to ver. 06.00.03.039. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 06.00.03.039.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_3.01.09.056","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_03.01.09.056.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"3.01.09.056"},{"DeviceName":"HPE_SR416_SR932_Gen10P_3.01.09.056","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_SR416_SR932_Gen10P_03.01.09.056.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"3.01.09.056"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE SR932i-p and SR416i-a Gen10 Plus Controllers"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"12458294","datemodified":"2022-02-08T08:00:12","file_list":["HPE_SR416_SR932_Gen10P_03.01.09.056.ilo","HPE_SR416_SR932_Gen10P_03.01.09.056.xml","payload.json"],"md5sum":"07376f349cae5860dd651efdf15696eb","name":"HPE_SR416_SR932_Gen10P_03.01.09.056.fwpkg","release":"2022-02-08T07:55:40","revision":"0","sha1sum":"8b81332d97de637eebae6713dff12c1f0dfa53fc","size":"11MB","target_guids":["a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"type_of_change":"1","version":"03.01.09.056"}],"id":{"product":"37b8041b7e7643398842e72c780d3745","version":"2b7b9fbf71784012a5a6b1b62803e700"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus  Controllers"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-15T09:39:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>For OEM usage</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Support UBM downstream device</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"02941590","sw_key_expectedpath":"firmware"},{"name":"02DC1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD2"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"WpariscASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB016000JXLBA and MB018000JXLAU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20359631","datemodified":"2021-08-30T05:55:43","file_list":["/CP049256_BUILD_1.data","/CP049256.vmexe","/CP049256.vmexe64","/CP049256.vmfile","/CP049256_VMw.zip","/CP049256.xml","/payload.json","/CP049256_VMw.zip/index.xml","/CP049256_VMw.zip/vendor-index.xml","/CP049256_VMw.zip/metadata.zip","/CP049256_VMw.zip/vib20/CP049256/HPE_bootbank_CP049256_HPD2.1-7.0.0.15843807.vib","/CP049256_VMw.zip/metadata.zip/vendor-index.xml","/CP049256_VMw.zip/metadata.zip/vmware.xml","/CP049256_VMw.zip/metadata.zip/vibs/CP049256-1448076509749438707.xml","/CP049256_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049256_HPD2.1-7.0.0.15843807.xml"],"md5sum":"f37b41fa3bd970a6b8e051b691e48bcb","name":"CP049256.zip","release":"2021-08-30T05:51:24","revision":"0","sha1sum":"d0c61fdcae830a126b37cb8ae2c6b0579723a3c1","size":"19MB","target_guids":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP049256","version":"HPD2.1-7.0.0.15843807"}]}],"id":{"product":"97b8f64d84c04c1a9c4048cae29b4037","version":"889aa37fe86b45a4b6a478e53c7ca87d"},"installation":{"command":"CP041025.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB016000JXLBA","target_guid":"4d2340a5-3042-3631-3030-304a584c4241","type":"sas"},{"id":"MB018000JXLAU","target_guid":"4d2340a5-3042-3831-3030-304a584c4155","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-11T18:25:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field changed from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo; and Reliability improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB018000JXLAU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JXLBA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 7.0."},{"lang":"ja","x_late":"このパッケージには、ESXi 7.0上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"28034091","datemodified":"2022-02-05T13:51:12","file_list":["/CP050331.vmexe64","/CP050331.vmfile","/CP050331.xml","/CP050331_VMw.zip","/payload.json","/README.txt","/CP050331_VMw.zip/index.xml","/CP050331_VMw.zip/vendor-index.xml","/CP050331_VMw.zip/metadata.zip","/CP050331_VMw.zip/vib20/CP050331/HPE_bootbank_CP050331_1.0.0-7.0.0.15525992.vib","/CP050331_VMw.zip/metadata.zip/vendor-index.xml","/CP050331_VMw.zip/metadata.zip/vmware.xml","/CP050331_VMw.zip/metadata.zip/vibs/CP050331-7034184952667091650.xml","/CP050331_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050331_1.0.0-7.0.0.15525992.xml"],"md5sum":"b47bd43865c675f77b2405f2acefe41e","name":"CP050331.zip","release":"2022-02-05T16:53:35","revision":"0","sha1sum":"66254f9d78bc33346c694f8c21ffd7781edd5c8d","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050331","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"d1f6d486a5d9456eb4b15539009012ca","version":"e5f09889454d4934a0f1c077a5d194d4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p>オフライン：    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます。</p>\n\n<p>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:<br />\n    適切なSPPをダウンロードします。<br />\n    SPPにコンポーネントを追加します。   <br />\n    アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します  <br />\n    アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。 <br />\n    ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、SPPのドキュメントを参照してください。<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>注記: SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:  <br />\n    vSphereクライアントにログインします。    <br />\n    インベントリツリーのサーバーまたはクラスターを選択します。 <br />\n    HPE Insight Managementタブをクリックします    <br />\n    HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</p>\n\n<p>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 <br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります)  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 7.0）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T07:18:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1014:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1200:</strong></p>\n\n<p>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.31.1014:</strong></p>\n\n<p>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). Note: If the port does not go up, switch to Force mode.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li>\n\t<li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following device&nbsp;has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB014000JWTFD and MB012000JWTFC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3049624","datemodified":"2021-08-13T12:13:40","file_list":["cp049123.xml","cpqsetup.exe","payload.json","setup.dll","TAMG07scHPD8.REL"],"md5sum":"e8361dd41777d06872165979188fe0dc","name":"cp049123.exe","release":"2021-08-13T12:06:18","revision":"0","sha1sum":"41f035d8b75f57f5564e15d04ae907a4375ce84f","size":"2MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"b24f5415c77d43548ef3f4466312e507","version":"53ad7472344e43239ac3d54794534a73"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T15:24:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 6.5用lsi-mrコントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"196276","datemodified":"2019-12-20T07:05:28","file_list":["/cp042803.xml","/Release_Notes_lsi-mr3-7.706.09.00-1OEM_6.5.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/lsi-mr3-7.706.09.00-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/doc/README.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/doc/release_note_lsi-mr3_7.706.09.00-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/vendor-index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/vib20/lsi-mr3/Avago_bootbank_lsi-mr3_7.706.09.00-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00.xml","/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-12102431.zip/VMW-ESX-6.5.0-lsi_mr3-7.706.09.00-offline_bundle-12102431.zip/metadata.zip/vibs/lsi-mr3-1676736928.xml"],"md5sum":"5ba8a09854f6eba2db3db81a5d66b62d","name":"cp042803.zip","release":"2019-12-20T07:04:05","revision":"0","sha1sum":"3a51bb1ddb08cdf09040d9df62afc427c837be31","size":"191KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"1","version":"2019.12.13","vib_list":[{"name":"lsi-mr3","version":"7.706.09.00-1OEM.650.0.0.4598673"}]}],"id":{"product":"2b02357c33734bfeaaf1c4331f948d7c","version":"67421128b90e425a88d7ffedc6cd163e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":100,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller (64-bit) Driver for vSphere 6.5 (Driver Component)"},{"lang":"ja","x_late":"vSphere 6.5用HPE SmartアレイP824i-p MRコントローラー（64ビット）ドライバー（ドライバーコンポーネント）"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-01-13T06:52:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Addressed a vSAN Fault Tolerance test failure seen in JBOD mode.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-mr3:7.706.09.00-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5528574","datemodified":"2021-07-23T07:20:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/CP048163.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/SMKRASD9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-af802bb412-HPD9-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048163.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048163.scexe"],"md5sum":"18003c8a6c54038c83157ef607b17c8b","name":"firmware-hdd-af802bb412-HPD9-8.1.x86_64.rpm","release":"2021-07-23T07:08:14","revision":"0","sha1sum":"21628c63d4f00963a1a95fedd36884be77973595","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"c89e43e26231479bbdf6b9f0111deee2","version":"15e01943e6134b8a936804ec42e1f124"},"installation":{"command":"CP040274.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:17:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1307018","datemodified":"2021-12-14T00:43:07","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py2.7.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.4.0","./usr/share/doc/packages/libvma-9.4.0/CHANGES","./usr/share/doc/packages/libvma-9.4.0/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"75753d25a0c6e22566feabc7bff987ad","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.sles12sp4.x86_64.rpm","release":"2021-12-13T23:24:05","revision":"0","sha1sum":"838df7754b80e16c89c3ed2ee21dc628d8c2a57e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.5"},{"bytes":"1607358","datemodified":"2021-12-14T00:44:21","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/base","./lib/modules/4.12.14-94.41-default/updates/drivers/base/auxiliary.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"55e31d8d095e566968993ec8efb66fc5","name":"mlnx-ofa_kernel-kmp-default-5.5_k4.12.14_94.41-OFED.5.5.1.0.3.1.sles12sp4.x86_64.rpm","release":"2021-12-13T23:24:05","revision":"0","sha1sum":"5aa46fdeb0864ef3b296f8289e83b34452f2a469","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"5.5"}],"id":{"product":"1f96d5ce1b7c4e7fae4a08d7d5e4898d","version":"37514e42a00540b79753d69d10b53741"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.sles12sp4.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.5_k4.12.14_94.41-OFED.5.5.0.4.4.1.sles12sp4.x86_64.rpm</strong><br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"SPSGen10_04.01.04.601.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.601"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains the HPE Gen10 SPS Firmware for HPE Gen10 Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージには、HPE Gen10サーバー用のHPE Gen10 SPSファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8413358","datemodified":"2022-01-26T03:52:39","file_list":["payload.json","SPSGen10_04.01.04.601.signed.bin","SPSGen10_04.01.04.601.xml"],"md5sum":"969fa3ec3250914bae937c8adac36f81","name":"SPSGen10_04.01.04.601.fwpkg","release":"2022-01-26T03:48:26","revision":"0","sha1sum":"fdedf45c37840aea24fb369e0c55d5ed67ffc4d4","size":"8MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.04.601"}],"id":{"product":"c4ff2ade728c42bfb931931df173daf9","version":"daedb321fec6486495d78f2405c169a6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"ROMフラッシュ ファームウェアパッケージ - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T03:47:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 04.01.04.505(B) contains updates to the firmware packaging and is functionally equivalent to ver. 04.01.04.505. It is not necessary to upgrade with Revision B if a previous component revision was used to upgrade the firmware to version 04.01.04.505.</p>\n\n<p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware addresses an issue where not all PCIe devices will be managed properly by the system when there are more than 16 PCIe devices present in the platform. This would include PCIe devices in PCIe slots or NVMe drives. This issue would typically manifest itself as iLO Firmware not properly reporting thermals from a device when a server was in this heavily loaded configuration.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2021.2 guidance.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEFNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45464e43","Version":"HPD9"},{"DeviceName":"MB6000JEFND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRASD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45464e44","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEFNC and MB6000JEFND"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEFNCおよびMB6000JEFND"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17495665","datemodified":"2021-08-26T19:56:59","file_list":["/CP048367_BUILD_3.data","/CP048367.vmexe","/CP048367.vmexe64","/CP048367.vmfile","/CP048367_VMw.zip","/CP048367.xml","/payload.json","/CP048367_VMw.zip/index.xml","/CP048367_VMw.zip/vendor-index.xml","/CP048367_VMw.zip/metadata.zip","/CP048367_VMw.zip/vib20/CP048367/HPE_bootbank_CP048367_HPD9.3-7.0.0.15843807.vib","/CP048367_VMw.zip/metadata.zip/vendor-index.xml","/CP048367_VMw.zip/metadata.zip/vmware.xml","/CP048367_VMw.zip/metadata.zip/vibs/CP048367-1879748335820545526.xml","/CP048367_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048367_HPD9.3-7.0.0.15843807.xml"],"md5sum":"660c8fff3c1eeda5f15f0d88452eab77","name":"CP048367.zip","release":"2021-08-26T19:51:41","revision":"0","sha1sum":"0df1d4f085449637de1f3870d03864912245e5ae","size":"16MB","target_guids":["002340a5-4d00-3442-3030-304a45464e43","002340a5-4d00-3642-3030-304a45464e44"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048367","version":"HPD9.3-7.0.0.15843807"}]}],"id":{"product":"334426b326da4b9caa59be228e5282e3","version":"da2acbbd90834d94b0ee81f3b4935a81"},"installation":{"command":"CP039427.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEFNC and MB6000JEFND Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB4000JEFNCおよびMB6000JEFNDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEFNC","target_guid":"002340a5-4d00-3442-3030-304a45464e43","type":"sas"},{"id":"MB6000JEFND","target_guid":"002340a5-4d00-3642-3030-304a45464e44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T19:20:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEFNC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEFND","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//hld60404.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2346034","datemodified":"2021-08-31T07:43:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/CP046779.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/hld60404.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-mezz-qlogic-2021.10.01-1.6/x1590x02BC","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046779.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046779.scexe"],"md5sum":"a484158cd5a3cd3a2aa25bcc6451b083","name":"firmware-fc-mezz-qlogic-2021.10.01-1.6.x86_64.rpm","release":"2021-08-31T07:32:05","revision":"0","sha1sum":"91a2a97033273e00701ce760544a1473c2e56a36","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"82096ac8d4894962ba9da2e42c289f41","version":"09657a9786004586a98c11d978e22694"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;in an firmware-* folder.<br />\n&nbsp;<br />\n2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\nWhen the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command.<br />\n&nbsp;</p>\n\n<p>NOTE: During the flash operation, the message &quot;No Adapter Found!&quot; may appear in the logs. These messages do not indicate a problem with the firmware flash operation and may be ignored.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>\n\t<p>It is advised to provide read-write permissions on /var/tmp folder. Firmware deployment via Service Pack for ProLiant(SPP) might be unsuccessful in some cases , if read-write(rw) permissions are not enable on /tmp or /var/tmp directories.</p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters - Linux (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a behavior where the Unified Extensible Firmware Interface (UEFI) driver would force the system to reboot if one or both ports of a mezzanine adapter were not connected to an interconnect module during boot.</li>\n\t<li>Fixed a behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているHPE Intel i40eb 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1564808","datemodified":"2021-09-28T11:35:04","file_list":["cp047047.xml","cpqsetup.exe","cp_data.xml","i40eb65.cat","i40eb65.din","i40eb65.inf","i40eb65.sys","i40ebmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicIn40B.dll"],"md5sum":"f89c6c24f9d89d1fd9a0e9e0684058e4","name":"cp047047.exe","release":"2021-09-28T11:20:42","revision":"0","sha1sum":"a7efa88b6ff37c0954ed9aabd5e0196bd483246d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"13683c4504bf424989ac644f48168972","version":"126a6921de4442019fe63fbb611142e5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel i40ebドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library i40ebmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"i40eb65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom NetXtreme-E NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Broadcom NetXtreme-E NIC用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"356410","datemodified":"2021-10-01T18:37:36","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-305.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/80","./usr/lib/.build-id/80/01474b8b5687ddb9fb888cdad077cd04449293","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/ba83b10bd03e1e1990e889d00d8a54a0ec4bfe","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"db24e1c80902274b04067236185f4b1c","name":"kmod-bnxt_en-1.10.2-219.0.55.0.rhel8u4.x86_64.rpm","release":"2021-10-01T18:19:59","revision":"0","sha1sum":"5a94811ef00a309d9591e004a798ff29a62f9a6f","size":"348KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-219.0.55.0"},{"bytes":"350897","datemodified":"2021-10-01T18:43:17","file_list":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-240.el8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/.build-id","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/095a5cb0a4e96a1bb8c3fd31e451cca0b52a21","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/d1acad53e4bbe7a788cd74e430d7b64ef59ff5","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"md5sum":"0118a71cd6b7c5789bb291e80da70b03","name":"kmod-bnxt_en-1.10.2-219.0.55.0.rhel8u3.x86_64.rpm","release":"2021-10-01T18:19:59","revision":"0","sha1sum":"1415b25b7aa65997f1eb86c07b96a8f910885bd3","size":"342KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"type_of_change":"0","version":"1.10.2-219.0.55.0"}],"id":{"product":"12bc299e14c0483f95f66950ee1bea77","version":"21c1efe295c748e7b7e5b705bb9f919a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eドライバーfor Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 8 update 2 and Red Hat Enterprise Linux 8 update 3</li>\n\t<li>This product now supports PAM4 speeds information in&nbsp;ethtool tools&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where system crashed on doing driver unload load in loop when running broadcast traffic</li>\n\t<li>This product addresses an issue where bnxt_en module crashes with NULL pointer deference before ifup(bring up network interface)</li>\n\t<li>This product addresses an issue where kernel panic after PCIe AER(Advanced Error Reporting) device recovery successful</li>\n\t<li>This product addresses an issue where bnxt_en crashes with NULL pointer dereference when enabling SRIOV</li>\n\t<li>This product correct an error where ethtool -S tx_bytes and rx_bytes counter values far exceed actual values</li>\n\t<li>This product correct an error message when querying hwmon temperature on VF via sysfs</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n\t<li>This product addresses an issue where Virtual Functions (VFs) cannot be configured while the Physical Function (PF) interface is administratively down.</li>\n\t<li>This product addresses an issue where system crash when driver unloads while firmware reset is in progress.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"},{"name":"kmod-bnxt_en","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15740617","datemodified":"2021-08-27T10:43:49","file_list":["/CP048412_BUILD_3.data","/CP048412.vmexe","/CP048412.vmexe64","/CP048412.vmfile","/CP048412_VMw.zip","/CP048412.xml","/payload.json","/CP048412_VMw.zip/index.xml","/CP048412_VMw.zip/vendor-index.xml","/CP048412_VMw.zip/metadata.zip","/CP048412_VMw.zip/vib20/CP048412/HPE_bootbank_CP048412_HPG1.3-7.0.0.15843807.vib","/CP048412_VMw.zip/metadata.zip/vendor-index.xml","/CP048412_VMw.zip/metadata.zip/vmware.xml","/CP048412_VMw.zip/metadata.zip/vibs/CP048412--5067656484060346386.xml","/CP048412_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048412_HPG1.3-7.0.0.15843807.xml"],"md5sum":"a16ad0d4433ce55a616270e9f7cd0497","name":"CP048412.zip","release":"2021-08-27T10:38:53","revision":"0","sha1sum":"8e9ee152dc26da53ef6d77ba77660f17db058ff5","size":"15MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048412","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"d568c20f8443428c99b5421748aa1148","version":"a895abfb168648d3baf79086f736240e"},"installation":{"command":"CP042540.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL, and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T07:20:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"}],"files":[{"bytes":"3341568","datemodified":"2019-10-24T14:37:03","file_list":["/cp039936.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"fa4361c79e2869122c946da143c62bed","name":"cp039936.zip","release":"2019-10-24T19:37:03","revision":"0","sha1sum":"95a8b6c220987ec7f4ee35fe6da18acda5eb4273","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"957f29fa54a8424d9d2bb2a2851bdb01","version":"a32b530800ed48e1b2c6c24bcfddb559"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"129879","datemodified":"2021-11-05T02:53:30","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/7d1ef18be1f50f2f59e4e6103a3bda0371494c","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"ff4f3885382dd67c4a3f1ccabdb5a7b5","name":"kmod-hp-igb-6.8.5-2.rhel7u9.x86_64.rpm","release":"2021-11-05T02:44:57","revision":"0","sha1sum":"84f71eef781ee5cc944cb0d3c268a5b70029f045","size":"126KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.8.5-2"},{"bytes":"129880","datemodified":"2021-11-05T02:56:24","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/bde990557479e16cf2a7894a009aab1bd327db","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"md5sum":"1a6a8e7040648e8924c6b3a82d6684fe","name":"kmod-hp-igb-6.8.5-2.rhel7u8.x86_64.rpm","release":"2021-11-05T02:44:57","revision":"0","sha1sum":"d6703daa48b6a827645b759e5a9b8722ccba636e","size":"126KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"type_of_change":"1","version":"6.8.5-2"}],"id":{"product":"8641d1fe608b4b84a83d535f2b785a88","version":"6db4ceb5e7134dc1b25a24b5833c2e31"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel igb 驱动程序"},{"lang":"ja","x_late":"HPE Intel igbドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-05T01:47:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Linux Firmware upgrade utility v.1.22.5</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-igb","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD5"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA15SEe0HPD5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG001800JWJNL and EG002400JWJNN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNLおよびEG002400JWJNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16189129","datemodified":"2021-12-07T05:21:29","file_list":["/CP050184_BUILD_3.data","/CP050184.vmexe","/CP050184.vmexe64","/CP050184.vmfile","/CP050184_VMw.zip","/CP050184.xml","/payload.json","/CP050184_VMw.zip/index.xml","/CP050184_VMw.zip/vendor-index.xml","/CP050184_VMw.zip/metadata.zip","/CP050184_VMw.zip/vib20/CP050184/HPE_bootbank_CP050184_HPD5.3-7.0.0.15843807.vib","/CP050184_VMw.zip/metadata.zip/vendor-index.xml","/CP050184_VMw.zip/metadata.zip/vmware.xml","/CP050184_VMw.zip/metadata.zip/vibs/CP050184-9002222071620853988.xml","/CP050184_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050184_HPD5.3-7.0.0.15843807.xml"],"md5sum":"75252d5a92fd5a71b513faa8fda39420","name":"CP050184.zip","release":"2021-12-07T05:15:40","revision":"0","sha1sum":"6628b83a8860e261b28ddffd71fd83a41b0c83a3","size":"15MB","target_guids":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP050184","version":"HPD5.3-7.0.0.15843807"}]}],"id":{"product":"d1014161143144dea5631e9b65f9f0d4","version":"a68e01d4eb644d65809397542931a013"},"installation":{"command":"CP041560.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for VMware ESXi - EG001800JWJNLおよびEG002400JWJNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG002400JWJNN","target_guid":"452340a5-3047-3230-3430-304a574a4e4e","type":"sas"},{"id":"EG001800JWJNL","target_guid":"452340a5-3047-3130-3830-304a574a4e4c","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-02T07:48:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This firmware mitigates a potential reliability concern.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWJNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG002400JWJNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG3"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG3"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG3"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG3"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG3"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5200SG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH, MK001920GWUGK Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and&nbsp;MK001920GWUGK&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5012884","datemodified":"2021-07-23T08:54:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/CP048189.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/M5200SG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048189.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048189.scexe"],"md5sum":"f68fc6e11f9a38abb267e09d7c26e347","name":"firmware-hdd-9e87eecb3f-HPG3-2.1.x86_64.rpm","release":"2021-07-23T08:41:11","revision":"0","sha1sum":"dc24b051cb048c7c9fa245a79d039c8d7b4a7a34","size":"4MB","target_guids":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"4cc24985bf9c485084dcadb54a29cb28","version":"e36ff6da611841979a34a23a103548fb"},"installation":{"command":"CP040781.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWSXF、VK000960GWSXH、VK001920GWSXK、MK000480GWUGF、MK000960GWUGH、MK001920GWUGKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK001920GWSXK","target_guid":"562340a5-304b-3130-3932-30475753584b","type":"sata"},{"id":"MK001920GWUGK","target_guid":"4d2340a5-304b-3130-3932-30475755474b","type":"sata"},{"id":"VK000960GWSXH","target_guid":"562340a5-304b-3030-3936-304757535848","type":"sata"},{"id":"MK000960GWUGH","target_guid":"4d2340a5-304b-3030-3936-304757554748","type":"sata"},{"id":"VK000480GWSXF","target_guid":"562340a5-304b-3030-3438-304757535846","type":"sata"},{"id":"MK000480GWUGF","target_guid":"4d2340a5-304b-3030-3438-304757554746","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T09:09:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000480GWUGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWUGK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWUGH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSXF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWSXK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSXH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP&nbsp;and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3594576","datemodified":"2021-07-25T13:09:13","file_list":["cp048569.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNSD3.rel"],"md5sum":"7cd3da5ad5bfb0374c1b925296a57cb0","name":"cp048569.exe","release":"2021-07-25T13:01:07","revision":"0","sha1sum":"ef4d0528a2f63e317d8a7b2c9e1e7c62038b1344","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"85555c0bf7a54baebd117b6f0dbd865a","version":"476c7383fb234fe09957cc990ad460e3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:56:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"3388752","datemodified":"2021-07-25T12:46:54","file_list":["cp048564.xml","cpqsetup.exe","payload.json","setup.dll","TAHARRG4.REL"],"md5sum":"9cfc623fcd198d6119f9334e04ebf808","name":"cp048564.exe","release":"2021-07-25T12:39:05","revision":"0","sha1sum":"546d4fbf0b9ed1e6e563b914806370f424c3ca36","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"dceed791e6be42c1ba1f138aa6af8451","version":"87bf924e90bc44bdab40dde93d2d6ec5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、および MB4000GDUPB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:04:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWEZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757455a42","Version":"HPGG"},{"DeviceName":"VK000480GWEZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757455a43","Version":"HPGG"},{"DeviceName":"VK000960GWEZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757455a44","Version":"HPGG"},{"DeviceName":"VK001920GWEZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757455a45","Version":"HPGG"},{"DeviceName":"MK000240GWEZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757455a46","Version":"HPGG"},{"DeviceName":"MK000480GWEZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757455a48","Version":"HPGG"},{"DeviceName":"MK000960GWEZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757455a4b","Version":"HPGG"},{"DeviceName":"MK001920GWHRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5100SGG.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757485255","Version":"HPGG"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGG<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPGB<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPGB</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3133016","datemodified":"2021-07-25T18:36:17","file_list":["cp048636.xml","cpqsetup.exe","M5100SGG.rel","payload.json","setup.dll"],"md5sum":"1009e0bca52b1f7cc68bc73cb5afb2dd","name":"cp048636.exe","release":"2021-07-25T18:28:05","revision":"0","sha1sum":"15a64674e7d1fe2c4c3bb828254eda28989e6258","size":"2MB","target_guids":["562340a5-304b-3030-3234-304757455a42","562340a5-304b-3030-3438-304757455a43","562340a5-304b-3030-3936-304757455a44","562340a5-304b-3130-3932-304757455a45","4d2340a5-304b-3030-3234-304757455a46","4d2340a5-304b-3030-3438-304757455a48","4d2340a5-304b-3030-3936-304757455a4b","4d2340a5-304b-3130-3932-304757485255"],"type_of_change":"1","version":"HPGG"}],"id":{"product":"349d4407749e4a9fa71df176f3e03e78","version":"d178af394a5646a584827a312f5048a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWEZB, VK000480GWEZC, VK000960GWEZD, VK001920GWEZE, MK000240GWEZF, MK000480GWEZH, MK000960GWEZK and MK001920GWHRU Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWEZB、VK000480GWEZC、VK000960GWEZD、VK001920GWEZE、MK000240GWEZF、MK000480GWEZH、MK000960GWEZK、およびMK001920GWHRUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWHRU","target_guid":"4d2340a5-304b-3130-3932-304757485255","type":"sata"},{"id":"VK001920GWEZE","target_guid":"562340a5-304b-3130-3932-304757455a45","type":"sata"},{"id":"MK000240GWEZF","target_guid":"4d2340a5-304b-3030-3234-304757455a46","type":"sata"},{"id":"VK000240GWEZB","target_guid":"562340a5-304b-3030-3234-304757455a42","type":"sata"},{"id":"MK000480GWEZH","target_guid":"4d2340a5-304b-3030-3438-304757455a48","type":"sata"},{"id":"VK000480GWEZC","target_guid":"562340a5-304b-3030-3438-304757455a43","type":"sata"},{"id":"MK000960GWEZK","target_guid":"4d2340a5-304b-3030-3936-304757455a4b","type":"sata"},{"id":"VK000960GWEZD","target_guid":"562340a5-304b-3030-3936-304757455a44","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T15:58:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWHRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000240GWEZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWEZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWEZC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GWEZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWEZD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWEZK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWEZB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"8338836","datemodified":"2022-02-02T13:17:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/CP050333.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050333.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050333.scexe"],"md5sum":"99eab35e525310afcd48fc36356dece9","name":"firmware-nic-open-mellanox-eth-mft-1.0.6-1.1.x86_64.rpm","release":"2022-02-02T13:16:40","revision":"0","sha1sum":"b4a6b6a67e91565cc3fd464c608852c38270ad61","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.6"}],"id":{"product":"ec5ba4f75ae340e39f8e129f646a9647","version":"10673e149b114162a025ba4f3d9623e8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（Linux x86_64）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T07:18:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1014:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1200:</strong></p>\n\n<p>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.31.1014:</strong></p>\n\n<p>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). Note: If the port does not go up, switch to Force mode.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li>\n\t<li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following device&nbsp;has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D3600, D3700, D3610 and D3710 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D3600、D3700、D3610、およびD3710ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5048832","datemodified":"2021-12-20T08:44:26","file_list":["Config.xml","cp050070.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"md5sum":"672662d9fd41c42efe9ef1a00f27ff4f","name":"cp050070.exe","release":"2021-12-20T08:42:14","revision":"0","sha1sum":"0f9cd9ad3d7e8b76690b0a261b49a43d2688d6a6","size":"4MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"type_of_change":"1","version":"5.04"}],"id":{"product":"bce1dc60182942cc938b19de857de7fd","version":"6ec9643cd2d6411b9295eed394febd98"},"installation":{"command":"cpqsetup.exe","command_params":"/tD3600 /tD3700 /tD3610 /tD3710 /v5.04 /iReveille-Release-5.04-build-000.bin /lD3000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.&nbsp;After you are prompted for logon information, enter credentials for an account with management access rights.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"Windows (x64)向けHPE D3600/D3700/D3610/D3710 12Gb SASディスクエンクロージャーROMフラッシュコンポーネント"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D3600","target_guid":"b99dfb74-f0bc-464f-b418-cd18da6dd779","type":"sas"},{"id":"D3610","target_guid":"b99dfb74-f0bc-464f-b418-cd18142a1148","type":"sas"},{"id":"D3700","target_guid":"b99dfb74-f0bc-464f-b418-cd186af467e1","type":"sas"},{"id":"D3710","target_guid":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-24T09:13:08","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>The Enabled-ClusterS2D command now completes successfully when executed on a SATA drive within a D3610 disk enclosure for a NonStop solution.</p>\n\t</li>\n\t<li>\n\t<p>The smart carrier, which is the drive case for SAS drives, now authenticates in the D3610/D3710 drive enclosure.</p>\n\t</li>\n\t<li>\n\t<p>Added new 7-segment error codes E0 and E1 to report issues with Fan modules A and B, respectively. These new codes only apply to the D3610/D3710 and only display when running firmware 5.04.</p>\n\t</li>\n\t<li>\n\t<p>If the storage enclosure processor within the I/O module fails, a hard reset (power down and then power up) is executed to ensure the processor comes back online.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p879663226/v202692/20-D3000-Gen10RN504C_ED3.html\">&nbsp;<u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D3710","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3610","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3600","sw_key_expectedpath":"firmware:sd:disk_enclosure"},{"name":"D3700","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"},{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000240GWCEU、MK000480GWCEV、MK000960GWCFA、およびMK001920GWCFBドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MK000240GWCEU, MK000480GWCEV, MK000960GWCFA&nbsp;and MK001920GWCFB&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4665784","datemodified":"2021-07-23T07:48:13","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/CP048176.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/GS863aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7677644a25-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048176.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048176.scexe"],"md5sum":"9800057929cfe1d85316519079b72e9a","name":"firmware-hdd-7677644a25-HPG3-7.1.x86_64.rpm","release":"2021-07-23T07:34:14","revision":"0","sha1sum":"019ff21caf3f9d23f8a9b213a06c3be8c5c2188c","size":"4MB","target_guids":["4d2340a5-304b-3030-3234-304757434555","4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"8da11b65fc4a442eb7c1c3ce3ad367bb","version":"037658bbe87041298dcdcdc3267a9431"},"installation":{"command":"CP040341.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:13:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Release-1.79-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.79"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Release-1.79-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.79"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3648592","datemodified":"2021-09-01T12:00:00","file_list":["cp049339.xml","cpqsetup.exe","firmware-Release-1.79-build-000.bin.fw","payload.json","setup.dll"],"md5sum":"d59664a7de3d4d46c28aefd3430a87cd","name":"cp049339.exe","release":"2021-09-01T11:47:04","revision":"0","sha1sum":"5bb3a3cb7816133c5026eb71768e154eae6047ef","size":"3MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"1.79"}],"id":{"product":"ecd80496db274bbda7c43a5153ea6bdf","version":"89a30288ed65471dab27349024075a3d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.03またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong></strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.sh スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 4200バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-24T06:10:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n"},{"curr_enhancements_x_late":"<p>Added Win2022 Support</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB006000GWBXQおよびMB008000GWBYL "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6300174","datemodified":"2021-07-23T07:34:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/CP048104.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/TAGLXYG8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a1fd19f9ca-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048104.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048104.scexe"],"md5sum":"8fd9b86748eb18072985329d76743a01","name":"firmware-hdd-a1fd19f9ca-HPG8-6.1.x86_64.rpm","release":"2021-07-23T07:22:08","revision":"0","sha1sum":"d42a7d7090458a64301f9689b51acea5c9b0887e","size":"6MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"2e44a81a31b2430ba5be31f73e9e365e","version":"cfa375533e3841429371bab9287a415f"},"installation":{"command":"CP040782.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T16:46:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000960GXCLD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304758434c44","Version":"HPG2"},{"DeviceName":"VK001920GXCGP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304758434750","Version":"HPG2"},{"DeviceName":"VK003840GXCGQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304758434751","Version":"HPG2"},{"DeviceName":"VK007680GXCGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M5210AG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304758434752","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;-&nbsp;VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR&nbsp; Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4666576","datemodified":"2021-08-13T14:20:24","file_list":["cp049274.xml","cpqsetup.exe","M5210AG2.rel","payload.json","setup.dll"],"md5sum":"6c817e16858d26649eac4241d3671587","name":"cp049274.exe","release":"2021-08-13T14:12:04","revision":"0","sha1sum":"d24012691141fae058f0af023f2636fb5cb3c2e9","size":"4MB","target_guids":["562340a5-304b-3030-3936-304758434c44","562340a5-304b-3130-3932-304758434750","562340a5-304b-3330-3834-304758434751","562340a5-304b-3730-3638-304758434752"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"eba2d683ef74457085f02d6700a97d49","version":"100278b5b3674461b7008206c6b3edc3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000960GXCLD, VK001920GXCGP, VK003840GXCGQ and VK007680GXCGR  Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK000960GXCLD","target_guid":"562340a5-304b-3030-3936-304758434c44","type":"sata"},{"id":"VK007680GXCGR","target_guid":"562340a5-304b-3730-3638-304758434752","type":"sata"},{"id":"VK001920GXCGP","target_guid":"562340a5-304b-3130-3932-304758434750","type":"sata"},{"id":"VK003840GXCGQ","target_guid":"562340a5-304b-3330-3834-304758434751","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:08:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GXCGQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GXCGP","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK007680GXCGR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GXCLD","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG1800JEHMD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFL4CD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3830-304a45484d44","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG1800JEHMD"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG1800JEHMD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n"}],"files":[{"bytes":"3653824","datemodified":"2021-07-24T06:24:57","file_list":["cp048507.xml","cpqsetup.exe","HCFL4CD6.rel","payload.json","setup.dll"],"md5sum":"001f0399bab73e9a965a54f5acbf079c","name":"cp048507.exe","release":"2021-07-24T06:17:05","revision":"0","sha1sum":"03b30c1436225d31512082773371c48d4c5b31ff","size":"3MB","target_guids":["002340a5-4500-3147-3830-304a45484d44"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"8160f18bf46a4d4bb912b9b35f631323","version":"5b11a35d077f4aaf8227c9424906bfca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG1800JEHMD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG1800JEHMDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1800JEHMD","target_guid":"002340a5-4500-3147-3830-304a45484d44","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T08:27:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1800JEHMD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 SUSE Linux Enterprise Server 12 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"112805","datemodified":"2021-10-07T03:54:36","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"md5sum":"63b9bd300ecf9830b201c201464c2c28","name":"tg3-kmp-default-3.139b_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-10-07T03:41:11","revision":"0","sha1sum":"1b8b87307b95300c52ceb023184195f8468c73a1","size":"110KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"type_of_change":"0","version":"3.139b-2"}],"id":{"product":"446098f1e7d240bb85aed0cf4ebd644e","version":"49d932aadd7741b99f225678d05aa8d9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"159C","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-165f14e4159c","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n"},{"curr_enhancements_x_late":"<p>This product removed SUSE Linux Enterprise Server 12 Service Pack 4 supports.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"tg3-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3862352","datemodified":"2021-08-13T14:48:40","file_list":["cp049277.xml","cpqsetup.exe","K401HPG3.rel","payload.json","setup.dll"],"md5sum":"5523aa73f5494cb9d7d302c793a967b0","name":"cp049277.exe","release":"2021-08-13T14:40:27","revision":"0","sha1sum":"5671e71607652e77877f3970aeffe1433a383bdb","size":"3MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"8e8fd25144334177930f2db95d492320","version":"763c5f7344ee463caf82efecad197a87"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -VK000480GWTHA、VK000960GWTHB、VK001920GWTHC、およびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:35:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"58edf963-9038-4e01-80c5-59b770e09e25","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"UBM2_V1.20.signed.hex.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":true,"Type":"Firmware","UefiFlashable":true}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"V1.20"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This firmware package contains firmware for ProLiant Gen10Plus UBM2 storage backplanes. It can be installed online through the use of the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージには、ProLiant Gen10Plus UBM2ストレージバックプレーンのファームウェアが含まれています。これは、サポート対象のオペレーティングシステムでRESTfulインターフェイスツール（iLOrest）などのツールを使用して、オンラインでインストールできます。さらに、iLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが一元的にリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"63086","datemodified":"2022-02-23T02:22:47","file_list":["payload.json","UBM2_V1.20.signed.hex.ilo","UBM2_V1.20.xml"],"md5sum":"71c8e6a51c24f897d7270ea5b00e0612","name":"UBM2_V1.20.fwpkg","release":"2022-02-23T02:19:05","revision":"0","sha1sum":"3ff8f1a6a4ecf1299cf509caa38c687f958afb79","size":"61KB","target_guids":["9675b54e-1c96-44c3-a7a1-901502000000"],"type_of_change":"1","version":"1.20"}],"id":{"product":"d36299863db5430ea15927c19344f09a","version":"f23b0a3a38d34742a47f3c92e936b612"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - Gen10Plus UBM2 Backplane PIC Firmware"},{"lang":"ja","x_late":"ファームウェアパッケージ - Gen10Plus UBM2 Backplane PICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901502000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T14:12:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft&nbsp;Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issue</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM2PIC","sw_key_expectedpath":"firmware:ubmbackplane"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4191264","datemodified":"2021-07-23T11:18:05","file_list":["cp048673.xml","cpqsetup.exe","HLEAHasseFG3.rel","payload.json","setup.dll"],"md5sum":"ba5076f876154087abbed978bcd8a385","name":"cp048673.exe","release":"2021-07-23T11:09:05","revision":"0","sha1sum":"64ea822107011bf96b3a5c47af89efbb187877f5","size":"3MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"230d4b31fe374aebb4d538e99b933aee","version":"a42128dbe6134e72a7772d3d46773556"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:38:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG000600JWJNP and EG001200JWJNQ&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5948414","datemodified":"2021-07-23T08:36:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/CP048065.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/SSKYBT512ND4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048065.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048065.scexe"],"md5sum":"dbc7026b213245a3d8922faa225f4459","name":"firmware-hdd-bdfb8e99d9-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:23:06","revision":"0","sha1sum":"2eceb3bcd1083873e4131551b3e5855d09878628","size":"5MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"73ec3bde4c824e4abd7a12e09eb4bcb4","version":"a34900e116ac44bd9af7cab566071acb"},"installation":{"command":"CP041693.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T11:08:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS2, provides Windows 64-bit support for HPE Smart Array P824i-p MR 64-bit controller"},{"lang":"ja","x_late":"このドライバーMegaSAS2は、HPE SmartアレイP824i-p MR 64-bitコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"1028840","datemodified":"2019-09-24T12:48:35","file_list":["cp038009.xml","cpqsetup.exe","generic.dll","install.xml","megasas2.cat","MegaSAS2.inf","megasas2.pdb","MegaSas2.sys","nodev.inf"],"md5sum":"f574e5414b7ea243e435bb0bf01940ca","name":"cp038009.exe","release":"2019-09-24T12:47:02","revision":"0","sha1sum":"55738b6cd55742c97649298d4b2ac66dd3047c23","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9d4f074d"],"type_of_change":"1","version":"6.714.18.0"}],"id":{"product":"e7a36c6c410640b394ca5fa6b0bcd1f9","version":"1db8fc89c00d46ee821089c4f52a593e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR 64-bit controller driver for Microsoft Windows 2019 edition."},{"lang":"ja","x_late":"Windows 2019エディション用HPE SmartアレイP824i-p MR 64-bitコントローラードライバー。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-11-30T09:00:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Yet to update.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"MegaSas2.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYYV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6SD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595956","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000JVYYV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000JVYYV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV&nbsp;Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5555260","datemodified":"2021-07-23T07:44:40","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/CP048172.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/SMPN6SD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0595c2a887-HPD2-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048172.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048172.scexe"],"md5sum":"f8150396d7023267727c4b4e7166b754","name":"firmware-hdd-0595c2a887-HPD2-8.1.x86_64.rpm","release":"2021-07-23T07:32:06","revision":"0","sha1sum":"df7567ddebd7f84b06936735375c4f53666294ee","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595956"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"2dc381cd01314b3ba2f24f5b5647b2a3","version":"59f6378837854cf7b31399705a702008"},"installation":{"command":"CP040307.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000JVYYV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JVYYVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB6000JVYYV","target_guid":"002340a5-4d00-3642-3030-304a56595956","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:57:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JVYYV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"22_32_1010-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter"},{"lang":"ja","x_late":"HPE Ethernet 100Gb 2ポートQSFP56 MCX623106AS-CDATアダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter(P25960-B21)</td>\n\t\t\t<td>22.31.1014</td>\n\t\t\t<td>MT_0000000437</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2ポートQSFP56 MCX623106AS-CDATアダプター（P25960-B21）</td>\n\t\t\t<td>22.31.1014</td>\n\t\t\t<td>MT_0000000437</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"7006509","datemodified":"2021-12-07T09:54:01","file_list":["22_32_1010-MCX623106AS-CDA_Ax.pldm.signed","22_32_1010-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"md5sum":"f990c43c522a8e51f6d18ae024a26462","name":"22_32_1010-MCX623106AS-CDA_Ax.pldm.fwpkg","release":"2021-12-07T09:50:04","revision":"0","sha1sum":"564eca68fb6ea59a7854a5667e0c8cdb0460805a","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"type_of_change":"1","version":"22.32.1010"}],"id":{"product":"23c569ea92fb47f091a7a0c891acff72","version":"3d29b8520209448188259441ed4ca4af"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter"},{"lang":"ja","x_late":"HPE Ethernet 100Gb 2ポートQSFP56 MCX623106AS-CDATアダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 22.31.1014:</strong></p>\n\n<ul>\n\t<li>Set the cap to 0 for high index functions to avoid too many parallel Virtual Function(VF) NODNIC functions.</li>\n\t<li>Implemented a new Network Communications Services Interface(NC-SI) command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Phy counters are cleared x seconds after link is up. This feature can be configured and enabled via the ini fields using the NVconfig.</li>\n\t<li>Extended the Dynamic Flex Parser capabilities in order to support Real-time Transport Protocol(RTP) packets parsing.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>NVME traffic can run now on another vHCA than the emulation manager vHCA.</li>\n\t<li>Allows the device to be configured with more than 256 MSIX vectors per physical PCI function.</li>\n\t<li>Enabled measuring PCIe eye dynamic grading over PCIe Gen3 speed.</li>\n\t<li>Enabled hardware real time clock for virtualized environment.</li>\n\t<li>Added support for the following:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>Matching field ipv4_ihl in create_flow_group and set_flow_table_entry commands.</li>\n\t\t<li>Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.</li>\n\t\t<li>A single Packet Filter(PF) per NUMA for Socket-Direct without a host management.</li>\n\t\t<li>Full tunnel header matcher to VXLAN header (including VXLAN alert bit).</li>\n\t\t<li>A new bit (&quot;data_in_order&quot;) to query the Queue Pair(QP) and allow a process/library to detect when the Adaptive Routing(AR) is enabled.</li>\n\t\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.31.1014:</strong></p>\n\n<ul>\n\t<li>A fatal assert (0x8274) occured due to invalid inputs sent to the query_vport_state command.</li>\n\t<li>Occasionally, toggling one of the NIC&#39;s port might result in link down of the 2nd port.</li>\n\t<li>Incorrect indication of the function dependency in the SR-IOV capability in PCIe configuration space.</li>\n\t<li>A rare issue that caused the destroy DCT command to not work properly when there were packet drops on connect packets in the network .</li>\n\t<li>The rate select mechanism in QSFP modules is fixed.</li>\n\t<li>A fatal error issue eventually causing the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number was overwritten with a 32 bit number and erased the high bits during de-allocation.</li>\n\t<li>Initialized the rate table in the static configuration so it would be configured at the link-not-up scenarios.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>The TX queue got into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>&quot;ICM-cache-large-scale&quot; steering mode was not supported with NoDNIC boot.</li>\n\t<li>Classification issues with &quot;Passive&quot; cables.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 22.32.1010:</strong></p>\n\n<ul>\n\t<li>Set the cap to 0 for high index functions to avoid too many parallel Virtual Function(VF) NODNIC functions.</li>\n\t<li>Implemented a new Network Communications Services Interface(NC-SI) command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Phy counters are cleared x seconds after link is up. This feature can be configured and enabled via the ini fields using the NVconfig.</li>\n\t<li>Extended the Dynamic Flex Parser capabilities in order to support Real-time Transport Protocol(RTP) packets parsing.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>NVME traffic can run now on another vHCA than the emulation manager vHCA.</li>\n\t<li>Allows the device to be configured with more than 256 MSIX vectors per physical PCI function.</li>\n\t<li>Enabled measuring PCIe eye dynamic grading over PCIe Gen3 speed.</li>\n\t<li>Enabled hardware real time clock for virtualized environment.</li>\n\t<li>Added support for the following:\n\t<ul>\n\t\t<li>Matching field ipv4_ihl in create_flow_group and set_flow_table_entry commands.</li>\n\t\t<li>Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.</li>\n\t\t<li>A single Packet Filter(PF) per NUMA for Socket-Direct without a host management.</li>\n\t\t<li>Full tunnel header matcher to VXLAN header (including VXLAN alert bit).</li>\n\t\t<li>A new bit (&quot;data_in_order&quot;) to query the Queue Pair(QP) and allow a process/library to detect when the Adaptive Routing(AR) is enabled.</li>\n\t\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t</ul>\n\t</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 22.32.1010:</strong></p>\n\n<ul>\n\t<li>A fatal assert (0x8274) occured due to invalid inputs sent to the query_vport_state command.</li>\n\t<li>Occasionally, toggling one of the NIC&#39;s port might result in link down of the 2nd port.</li>\n\t<li>Incorrect indication of the function dependency in the SR-IOV capability in PCIe configuration space.</li>\n\t<li>A rare issue that caused the destroy DCT command to not work properly when there were packet drops on connect packets in the network .</li>\n\t<li>The rate select mechanism in QSFP modules is fixed.</li>\n\t<li>A fatal error issue eventually causing the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number was overwritten with a 32 bit number and erased the high bits during de-allocation.</li>\n\t<li>Initialized the rate table in the static configuration so it would be configured at the link-not-up scenarios.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>The TX queue got into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>&quot;ICM-cache-large-scale&quot; steering mode was not supported with NoDNIC boot.</li>\n\t<li>Classification issues with &quot;Passive&quot; cables.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK75H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK75H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK75H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK75H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK75H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK75H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK75H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"MPK75H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK75H5Q"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MZXL5800HBHQ-000H3、MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL51T9HBJR-000H3、MZXL53"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for&nbsp;VMware ESXi - &nbsp;MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp;MPK75H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; MPK73H5Q</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 0px; margin-right: 0px; text-align: left;\">Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"25527034","datemodified":"2021-08-27T07:12:22","file_list":["/CP048456_BUILD_3.data","/CP048456.vmexe","/CP048456.vmexe64","/CP048456.vmfile","/CP048456_VMw.zip","/CP048456.xml","/payload.json","/CP048456_VMw.zip/index.xml","/CP048456_VMw.zip/vendor-index.xml","/CP048456_VMw.zip/metadata.zip","/CP048456_VMw.zip/vib20/CP048456/HPE_bootbank_CP048456_MPK75H5Q.3-7.0.0.15843807.vib","/CP048456_VMw.zip/metadata.zip/vendor-index.xml","/CP048456_VMw.zip/metadata.zip/vmware.xml","/CP048456_VMw.zip/metadata.zip/vibs/CP048456--8892620352000752534.xml","/CP048456_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048456_MPK75H5Q.3-7.0.0.15843807.xml"],"md5sum":"8cd1462d76598671e5f6a57c8676b359","name":"CP048456.zip","release":"2021-08-27T07:06:47","revision":"0","sha1sum":"d7304a54e30e5f056c488597904d2dd9bd5aca6e","size":"24MB","target_guids":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"type_of_change":"2","version":"MPK75H5Q","vib_list":[{"name":"CP048456","version":"MPK75H5Q.3-7.0.0.15843807"}]}],"id":{"product":"6a808075e9fa4bc19e7d11fd17511784","version":"d06603b0a5e04897a9cf276e2a6a5b21"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MZXL5800HBHQ-000H3、 MZXL51T6HBJR-000H3、MZXL53T2HBLS-000H3、MZXL56T4HALA-000H3、MZXL512THALA-000H3、 MZXL5960HBHQ-000H3、MZXL51T9HBJR-000H3、MZXL53T8HBLS-000H3、MZXL57T6HALA-000H3および MZXL515THALA-00H3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MZXL515THALA-000H3","target_guid":"4d2340a5-585a-354c-3135-54486d0092b3","type":"nvme"},{"id":"MZXL512THALA-000H3","target_guid":"4d2340a5-585a-354c-3132-544895b51a17","type":"nvme"},{"id":"MZXL57T6HALA-000H3","target_guid":"4d2340a5-585a-354c-3754-364820f1a5c1","type":"nvme"},{"id":"MZXL56T4HALA-000H3","target_guid":"4d2340a5-585a-354c-3654-34482ab7fb8f","type":"nvme"},{"id":"MZXL53T8HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-38483310a47b","type":"nvme"},{"id":"MZXL53T2HBLS-000H3","target_guid":"4d2340a5-585a-354c-3354-324884d9e9f5","type":"nvme"},{"id":"MZXL51T6HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-36487a9b1618","type":"nvme"},{"id":"MZXL5800HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3830-3048d90154e8","type":"nvme"},{"id":"MZXL51T9HBJR-000H3","target_guid":"4d2340a5-585a-354c-3154-3948e450274f","type":"nvme"},{"id":"MZXL5960HBHQ-000H3","target_guid":"4d2340a5-585a-354c-3936-304894dc03d2","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T08:54:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed False UECC issue at idle power mode (12.8TB and 15.36TB only).</li>\n\t<li>Apply PCLK running PHY option, PLL clock disable can be avoided in lane 0 missing case.</li>\n\t<li>Old FW download Blocking.</li>\n\t<li>FW is changed off the option of TX data alignment for each lane.</li>\n\t<li>FW is changed to clear the interrupt after TLP Complete when PCIe config read operation.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us\" style=\"color: rgb(5, 99, 193); text-decoration: underline;\">https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00113342en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MZXL512THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5800HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL57T6HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T2HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL5960HBHQ-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL53T8HBLS-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL56T4HALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL515THALA-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T6HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MZXL51T9HBJR-000H3","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4439310","datemodified":"2021-08-26T09:01:15","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.3.18-22-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"e1cf269a8de7bbd246e2b16dd5127ca6","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-26T08:52:05","revision":"0","sha1sum":"595b38976c4e2e88890c9f7a21aba3c4fc3225bc","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"2ef4b1fccb0b4e4aa4c8281327ada522","version":"4bb8c4b537ad44f0820b07a1e0a96ec6"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_53-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Improve detection and recovery from conditions described in customer advisory available at <a href=\"http://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-202.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.02"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for VMware ESXi &ndash; HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.02<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10<strong>&nbsp;</strong></li>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.02<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.00<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.00<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n      なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>ベイ1〜10の場合、電源を入れ直した後、またはホットプラグ後にハードドライブが表示されない場合があります<strong></strong></li>\n\t<li>SUSE LINUX Enterprise Server 15 OSのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p>      なし</p>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"4232140","datemodified":"2019-10-16T11:02:13","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/CP041630.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/She-202.fuf.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-2.02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP041630.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP041630.scexe"],"md5sum":"3099b511b560a777efe2690fcd66194d","name":"firmware-smartarray-1d0696d939-2.02-1.1.x86_64.rpm","release":"2020-02-12T00:00:00","revision":"1","sha1sum":"449015468bd689ca0401ae6fece41ec3c7e53310","size":"4MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef"],"type_of_change":"1","version":"2.02"}],"id":{"product":"4bd9dbd3dc9b4fbeb5492d2bb64a92e4","version":"09a21070911749309a3aa62abd03240f"},"installation":{"command":"CP041630.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037680.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-1d0696d939-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037680.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-1d0696d939-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul>\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします：  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP037680.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-smartarray-1d0696d939-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./CP037680.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*'の場所に<em>./setup</em>を追加してください。</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート:</em></strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-1d0696d939-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-1d0696d939-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux (x64) – HPE D2500sbストレージブレード用HPE SASエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-05T03:17:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11401656","datemodified":"2022-03-08T10:50:19","file_list":["cp051162.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_2.62_03_08_2022.signed.flash"],"md5sum":"bac96c46691a59fde997fc7b4e411c53","name":"cp051162.exe","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"833e43bbb791f634737cf2bceb7ef4e395084f12","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"169b01f1c4c245bc854a8424af9a5f85","version":"7dcbd4f821b64b2e990cd585f3029370"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:19","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under SUSE Linux Enterprise Server 12 SP4 x86_64."},{"lang":"ja","x_late":"この製品は、SUSE Linux Enterprise Server 12 SP4 x86_64下で動作するサポートされたHPE Broadcom NetXtreme-Eアダプターカード用のRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22819","datemodified":"2021-02-11T00:35:25","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav16.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"b9ead5601b07c35eaf3e74dffbbeb92a","name":"libbnxt_re-218.0.7.0-sles12sp4.x86_64.rpm","release":"2021-02-11T00:32:05","revision":"0","sha1sum":"13c1ef59e105372ad73edd4e883b67ed8c3e7f59","size":"22KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"9f0b7493acab4ced83fdf80f7583cdfd","version":"c552a078e5e7474bb80d4e4f8cd3f064"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">受信トレイライブラリと競合する可能性があるHPE Broadcom RoCEライブラリのインストールまたはアップデート中に--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 12 SP4"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 SP4用HPE Broadcom NetXtreme-E RoCEライブラリ"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product corrects an issue which RoCE bond is not getting created automatically after system reboot</li>\n\t<li>This product corrects an issue which errors/performance may degrades after hot plug operation is performed</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product now supports rdma-core v29(rdma user space application)</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"12.8.528.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.528.21"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"6698512","datemodified":"2022-01-31T09:15:51","file_list":["cp049957.xml","cpqsetup.exe","elxflashStandalone-windows-12.8.528.12-1/boot/","elxflashStandalone-windows-12.8.528.12-1/firmware/","elxflashStandalone-windows-12.8.528.12-1/firmware/B12852821.grp","elxflashStandalone-windows-12.8.528.12-1/firmware/P12852821.grp","elxflashStandalone-windows-12.8.528.12-1/win/","elxflashStandalone-windows-12.8.528.12-1/win/elxflash.bat","elxflashStandalone-windows-12.8.528.12-1/win/winlpcfg.bat","elxflashStandalone-windows-12.8.528.12-1/win/x64/","elxflashStandalone-windows-12.8.528.12-1/win/x64/boot/","elxflashStandalone-windows-12.8.528.12-1/win/x64/elxflash.exe","elxflashStandalone-windows-12.8.528.12-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/firmware/","elxflashStandalone-windows-12.8.528.12-1/win/x64/fwmatrix.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/libdfc.dll","elxflashStandalone-windows-12.8.528.12-1/win/x64/RM.INI","elxflashStandalone-windows-12.8.528.12-1/win/x64/WinLpCfg.exe","firmware/B12852821.grp","firmware/P12852821.grp","fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","elxflashStandalone-windows-12.8.528.12-1/win/x64/readme.txt","reference.xml"],"md5sum":"55b8b170202595d5000e0965bd1619a2","name":"cp049957.exe","release":"2022-01-31T09:00:11","revision":"0","sha1sum":"270d1b5634aba03f571e3f8ce3a29f61a918dbf5","size":"6MB","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2022.03.01"}],"id":{"product":"b929c06b33df46a182acd3e907e0dc53","version":"e0c8ca5d8f6449beb8f28b95016903f0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.<br />\nThe downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<br />\nダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019/2022 x64"},{"lang":"ja","x_late":"HPEファームウェアフラッシュfor Emulexファイバーチャネルホストバスアダプター - Microsoft Windows Server 2016/2019/2022 x64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE, and VO1600JEABF"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：VK0400JEABD、VK0800JEABE、およびVO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp; &nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for Linux (x64) - VK0400JEABD, VK0800JEABE and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4723017","datemodified":"2021-08-31T10:47:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/CP049411.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/TAPM2RD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a7ecf7465-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049411.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049411.scexe"],"md5sum":"e7dabb71c9e4984b7cffb973cae18195","name":"firmware-hdd-8a7ecf7465-HPD4-2.1.x86_64.rpm","release":"2021-08-31T10:35:13","revision":"0","sha1sum":"74f42a4ed3cfe7f767aa180b84b3723ce3de47c0","size":"4MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4"}],"id":{"product":"aeed5dab678d4be3a85806ba9711f37a","version":"a8e5fedf57aa4cbbab1bd27ca10d0cb1"},"installation":{"command":"CP031688.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK0400JEABD、VK0800JEABEおよびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:24:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Blade Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Blade Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1212736","datemodified":"2020-12-02T16:16:13","file_list":["cp045176.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","nicco4.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"b055f1cd42190cb6b23134bb7415aed5","name":"cp045176.exe","release":"2020-12-02T15:59:22","revision":"0","sha1sum":"70686ff56e186a30c1c78a8ad24ce0de0d105edc","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.199.0"}],"id":{"product":"1ba8b21e9855422b82a9a544b83e660c","version":"189458f390f640e7815970da71a7de27"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation libraries, ixtmsg.dll, nicco5.dll, and nicinitx.dll.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VR000150GWEPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3135-304757455050","Version":"HPG1"},{"DeviceName":"VR000480GWEPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDMHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3052-3030-3438-304757455052","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VR000150GWEPP and VR000480GWEPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VR000150GWEPP and VR000480GWEPR Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4703297","datemodified":"2021-07-23T09:10:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/4IDMHPG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/CP048197.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b7eb905efe-HPG1-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048197.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048197.scexe"],"md5sum":"579a2bc1b3ec3c6be68c68b35d34cae6","name":"firmware-hdd-b7eb905efe-HPG1-7.1.x86_64.rpm","release":"2021-07-23T08:57:09","revision":"0","sha1sum":"c75f175a67575e09486919d5ed79289dfc5cbd1f","size":"4MB","target_guids":["562340a5-3052-3030-3135-304757455050","562340a5-3052-3030-3438-304757455052"],"type_of_change":"2","version":"HPG1"}],"id":{"product":"221cbeaf26c845fea3e521bf7ae66fa1","version":"7c789edd067c43e9800f83fcab4ab563"},"installation":{"command":"CP040348.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VR000150GWEPP and VR000480GWEPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VR000150GWEPPおよびVR000480GWEPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VR000480GWEPR","target_guid":"562340a5-3052-3030-3438-304757455052","type":"sata"},{"id":"VR000150GWEPP","target_guid":"562340a5-3052-3030-3135-304757455050","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T10:56:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes an issue which caused the drive to become non-functional.</li>\n\t<li>Fixes VPD Log D0h reported drive Sanitize times.</li>\n\t<li>Adds support for Security Log Page BBh.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VR000480GWEPR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VR000150GWEPP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v2.56 (01/20/2022)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U48_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8925376","datemodified":"2022-01-26T05:57:51","file_list":["cp050882.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_2.56_01_20_2022.signed.flash"],"md5sum":"57f3fe2478f3dfe6503386fc2efd17da","name":"cp050882.exe","release":"2022-01-26T05:56:21","revision":"0","sha1sum":"4c9fe89b7ba0c030814de91e59040b107d5b40c8","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"f22e031456d1410688940c3efe38cf1d","version":"387cb490885b4187a7b2739de19c0a5c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T05:32:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.\n\nNone<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"U48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for Broadcom NetXtreme-E devices for Mircosoft Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントには、Mircosoft Windows Server 2022用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1051784","datemodified":"2021-09-27T06:17:58","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp047542.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"076537b91f5cf10f8546c581878271ed","name":"cp047542.exe","release":"2022-01-10T00:00:00","revision":"1","sha1sum":"548bd6c2d2eaeb56a99a363bc5e52117a71fcec5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"219.0.44.0"}],"id":{"product":"b8bfd68496a643cdaece510776fb4ad2","version":"e4c8f19c2cb34e1a8f01793c89cdd3aa"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022"},{"lang":"ja","x_late":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41593","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41592","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41593","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41592","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41595","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41594","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41597","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41596","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41595","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41597","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41596","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D6","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41593","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41593","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41595","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41594","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41597","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41595","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41594","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41596","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"1807","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180714e41598","type":"pci","ven":"14e4"},{"dev":"1804","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180414e41598","type":"pci","ven":"14e4"},{"dev":"1801","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180114e41598","type":"pci","ven":"14e4"},{"dev":"1801","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180114e41599","type":"pci","ven":"14e4"},{"dev":"1809","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180914e41598","type":"pci","ven":"14e4"},{"dev":"1808","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180814e41599","type":"pci","ven":"14e4"},{"dev":"1806","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41599","type":"pci","ven":"14e4"},{"dev":"1806","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41598","type":"pci","ven":"14e4"},{"dev":"1807","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180714e41599","type":"pci","ven":"14e4"},{"dev":"1804","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180414e41599","type":"pci","ven":"14e4"},{"dev":"1808","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180814e41598","type":"pci","ven":"14e4"},{"dev":"1809","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180914e41599","type":"pci","ven":"14e4"},{"dev":"1806","subdev":"1751","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41751","type":"pci","ven":"14e4"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T06:10:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U44_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9098520","datemodified":"2022-01-26T04:44:39","file_list":["cp050872.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_2.56_01_20_2022.signed.flash"],"md5sum":"2e1b14257b87e3dcf53018cb485e8fe6","name":"cp050872.exe","release":"2022-01-26T04:42:28","revision":"0","sha1sum":"f84365d4bb7256419c3112eadce514247e2b077f","size":"8MB","target_guids":["00000000-0000-0000-0000-00000000021a"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"c5181c3bc0654e9db312aa6200639426","version":"4118afcb12124bf8b1340eb0e31f6ac5"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:51:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"}],"sw_keys":[{"name":"U44","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPD9"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPD9"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPD9"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPD9"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPD9"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPD9"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPD9"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPD9"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPD9"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPD9"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPD9"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPD9"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPD9"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM5ALLHPD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB、EO003200JWTCC およびMO001920JWWWV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB, EO003200JWTCC and MO001920JWWWV Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16157116","datemodified":"2021-08-30T04:42:56","file_list":["/CP049147_BUILD_1.data","/CP049147.vmexe","/CP049147.vmexe64","/CP049147.vmfile","/CP049147_VMw.zip","/CP049147.xml","/payload.json","/CP049147_VMw.zip/index.xml","/CP049147_VMw.zip/vendor-index.xml","/CP049147_VMw.zip/metadata.zip","/CP049147_VMw.zip/vib20/CP049147/HPE_bootbank_CP049147_HPD9.1-7.0.0.15843807.vib","/CP049147_VMw.zip/metadata.zip/vendor-index.xml","/CP049147_VMw.zip/metadata.zip/vmware.xml","/CP049147_VMw.zip/metadata.zip/vibs/CP049147--5481401386907158129.xml","/CP049147_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049147_HPD9.1-7.0.0.15843807.xml"],"md5sum":"1fbaf91e2e99444f57565c6485869253","name":"CP049147.zip","release":"2021-08-30T04:37:59","revision":"0","sha1sum":"38cd50bf3735497473860afff42e0daa6c88156d","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP049147","version":"HPD9.1-7.0.0.15843807"}]}],"id":{"product":"7004592a3bf74fab99a6fe756662ebbc","version":"ac5301788a5b4005bdc23be08a1c50c2"},"installation":{"command":"CP040758.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives"},{"lang":"ja","x_late":"オンライン HDD/SSDフラッシュコンポーネント for VMware ESXi  - VO000960JWTBK、VO001920JWTBL、VO003840JWTBN、VO007680JWTBP、MO000400JWTBQ、MO000800JWTBR、MO001600JWTBT、MO003200JWTBU、MO006400JWTCD、EO000400JWTBV、EO000800JWTCA、EO001600JWTCB ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680JWTBP","target_guid":"562340a5-304f-3730-3638-304a57544250","type":"sas"},{"id":"MO006400JWTCD","target_guid":"4d2340a5-304f-3630-3430-304a57544344","type":"sas"},{"id":"VO003840JWTBN","target_guid":"562340a5-304f-3330-3834-304a5754424e","type":"sas"},{"id":"MO003200JWTBU","target_guid":"4d2340a5-304f-3330-3230-304a57544255","type":"sas"},{"id":"EO003200JWTCC","target_guid":"452340a5-304f-3330-3230-304a57544343","type":"sas"},{"id":"VO001920JWTBL","target_guid":"562340a5-304f-3130-3932-304a5754424c","type":"sas"},{"id":"MO001600JWTBT","target_guid":"4d2340a5-304f-3130-3630-304a57544254","type":"sas"},{"id":"EO001600JWTCB","target_guid":"452340a5-304f-3130-3630-304a57544342","type":"sas"},{"id":"VO000960JWTBK","target_guid":"562340a5-304f-3030-3936-304a5754424b","type":"sas"},{"id":"MO000800JWTBR","target_guid":"4d2340a5-304f-3030-3830-304a57544252","type":"sas"},{"id":"EO000800JWTCA","target_guid":"452340a5-304f-3030-3830-304a57544341","type":"sas"},{"id":"MO000400JWTBQ","target_guid":"4d2340a5-304f-3030-3430-304a57544251","type":"sas"},{"id":"EO000400JWTBV","target_guid":"452340a5-304f-3030-3430-304a57544256","type":"sas"},{"id":"MO001920JWWWV","target_guid":"4d2340a5-304f-3130-3932-304a57575756","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T20:00:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWTBV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001920JWWWV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWTBL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWTBT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWTCB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWTCA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWTBR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWTBK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWTBP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWTBU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWTCD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWTBQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWTBN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO003200JWTCC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters."},{"lang":"ja","x_late":"このコンポーネントは、コンバージドネットワークおよびネットワークのみのアダプターのオペレーティングファームウェアをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29660459","datemodified":"2021-08-27T06:00:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/CP046767.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/brcmflashStandalone-linux-12.0.1345.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/firmware/oc14-12.0.1345.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-emulex-2021.10.01-1.8/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046767.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046767.scexe"],"md5sum":"0c69f6fc9ebd12e3aba651dd9635e166","name":"firmware-cna-emulex-2021.10.01-1.8.x86_64.rpm","release":"2021-08-27T05:46:26","revision":"0","sha1sum":"095bd3d495311cfac4932f6552df50fe651c61fa","size":"28MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"1c10253696bc48458c2c8df4ff0d1b8d","version":"fb42c1ed8e414c54ab34058297b816b0"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"},{"lang":"ja","x_late":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br />\n <br />\n 1. ファームウェアインストレーションツール：rpm -Uhv <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64-bitシステム） </p>\n\n<p> 2. 使用するシステムの適切な場所へcd し、./.setupを実行してファームウェアをアップデートします<br />\n <br />\n ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Fixed a behavior with internal engineering data display</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This component is only supported on RHEL7u8, RHEL7u9, RHEL8u3, SLES12SP5, SLES15SP2 OS&#39;s.</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware version:</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Universal Boot Image</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot BIOS</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E Dual Port Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E-T Dual Port Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EK000200GWEPD、EK000400GWEPE、EK000800GWEPF、およびEK001600GWEPHドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4665473","datemodified":"2021-07-23T10:30:32","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/CP048091.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/GS865aG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5bf9355926-HPG3-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048091.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048091.scexe"],"md5sum":"ec06fd11ccc42ebea7b7ff2fb05f2ea5","name":"firmware-hdd-5bf9355926-HPG3-7.1.x86_64.rpm","release":"2021-07-23T10:18:19","revision":"0","sha1sum":"4e0f5c839769025ccacb31c4d8aff98da46e007b","size":"4MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"916fe10c0989454da7fed6ac8080c703","version":"3e2bbcfdfe9f41dd9c2700127c0573fd"},"installation":{"command":"CP040347.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EK000200GWEPD、EK000400GWEPE、EK000800GWEPFおよびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T11:51:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB6000JVYZD and MB4000JVYZC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17596609","datemodified":"2021-08-27T04:38:42","file_list":["/CP048380_BUILD_2.data","/CP048380.vmexe","/CP048380.vmexe64","/CP048380.vmfile","/CP048380_VMw.zip","/CP048380.xml","/payload.json","/CP048380_VMw.zip/index.xml","/CP048380_VMw.zip/vendor-index.xml","/CP048380_VMw.zip/metadata.zip","/CP048380_VMw.zip/vib20/CP048380/HPE_bootbank_CP048380_HPD4.2-7.0.0.15843807.vib","/CP048380_VMw.zip/metadata.zip/vendor-index.xml","/CP048380_VMw.zip/metadata.zip/vmware.xml","/CP048380_VMw.zip/metadata.zip/vibs/CP048380--6716017894554559665.xml","/CP048380_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048380_HPD4.2-7.0.0.15843807.xml"],"md5sum":"4972af028762549b3e8f9992e387280d","name":"CP048380.zip","release":"2021-08-27T04:33:49","revision":"0","sha1sum":"aca3c37f9efc5f175956348531b6fb657ffc1217","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048380","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"d9159bc289514e83950fce1ae62143a1","version":"f4732a1b1b4947c1a8986c26e3763811"},"installation":{"command":"CP040636.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB6000JVYZD and MB4000JVYZC Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T08:27:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300FCSPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304643535048","Version":"HPD2"},{"DeviceName":"EG0450FCSPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3435-30464353504b","Version":"HPD2"},{"DeviceName":"EG0600FCSPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-30464353504c","Version":"HPD2"},{"DeviceName":"EG0900FCSPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA13SED2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-30464353504e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL&nbsp;and EG0900FCSPN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"15978078","datemodified":"2021-08-30T04:35:25","file_list":["/CP048255_BUILD_2.data","/CP048255.vmexe","/CP048255.vmexe64","/CP048255.vmfile","/CP048255_VMw.zip","/CP048255.xml","/payload.json","/CP048255_VMw.zip/index.xml","/CP048255_VMw.zip/vendor-index.xml","/CP048255_VMw.zip/metadata.zip","/CP048255_VMw.zip/vib20/CP048255/HPE_bootbank_CP048255_HPD2.2-7.0.0.15843807.vib","/CP048255_VMw.zip/metadata.zip/vendor-index.xml","/CP048255_VMw.zip/metadata.zip/vmware.xml","/CP048255_VMw.zip/metadata.zip/vibs/CP048255--8613360112209491030.xml","/CP048255_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048255_HPD2.2-7.0.0.15843807.xml"],"md5sum":"bf933df49f88ce3231c8d1e5418952e5","name":"CP048255.zip","release":"2021-08-30T04:30:20","revision":"0","sha1sum":"a4377182e83e9473cb1b2807ed534b6cf862af3e","size":"15MB","target_guids":["002340a5-4500-3047-3330-304643535048","002340a5-4500-3047-3435-30464353504b","002340a5-4500-3047-3630-30464353504c","002340a5-4500-3047-3930-30464353504e"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048255","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"4b93b2211c95475cbce045b32636c34c","version":"118de07f91df463085375b94d54ef1f9"},"installation":{"command":"CP040531.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300FCSPH, EG0450FCSPK, EG0600FCSPL and EG0900FCSPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - EG0300FCSPH、EG0450FCSPK、EG0600FCSPL、およびEG0900FCSPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG0300FCSPH","target_guid":"002340a5-4500-3047-3330-304643535048","type":"sas"},{"id":"EG0450FCSPK","target_guid":"002340a5-4500-3047-3435-30464353504b","type":"sas"},{"id":"EG0600FCSPL","target_guid":"002340a5-4500-3047-3630-30464353504c","type":"sas"},{"id":"EG0900FCSPN","target_guid":"002340a5-4500-3047-3930-30464353504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T09:11:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0450FCSPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300FCSPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900FCSPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600FCSPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4652759","datemodified":"2021-11-04T08:54:45","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-i40e","./lib/modules/5.3.18-22-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"25f729001a68a7884b7ea64ef0850ead","name":"hp-i40e-kmp-default-2.17.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-11-04T08:39:36","revision":"0","sha1sum":"5c5e74f1e1f388c2e2c2429c9af5ca3681f2678b","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"1","version":"2.17.4-1"},{"bytes":"4778871","datemodified":"2021-11-04T08:57:44","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-i40e","./lib/modules/5.3.18-57-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"md5sum":"eb57f8747f1ec6cc135c9bf23df9c271","name":"hp-i40e-kmp-default-2.17.4_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-11-04T08:39:36","revision":"0","sha1sum":"516be26c29707c0ce06d431663cfeb37f6592f09","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"type_of_change":"1","version":"2.17.4-1"}],"id":{"product":"7204c0f5c514445a87ae5a6c742f6a37","version":"3854f28f7ecf4e0f9adea652fa818f6b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where double count in crc_error and size_error counter.</li>\n\t<li>This product addresses an issue where ethtool status triggers a warning due to invalid size on veb_tc when veb-stats was enabled.</li>\n\t<li>This product addresses an issue where the kernel error message about PF reset failed.</li>\n\t<li>This product addresses an issue where the adapter LED is not blinking via ethtool command</li>\n\t<li>This product addresses an issue where physical functions cannot synchronize tpid setting</li>\n\t<li>This product addresses an issue where Linux kernel problem (kernel Oops) when Virtual Station Interface (VSI) reset.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-i40e-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D6020 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D6020ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5022496","datemodified":"2021-12-20T09:05:10","file_list":["Config.xml","cp050142.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"md5sum":"6ae9fbaeb24e1af1137bba864b0bb0ec","name":"cp050142.exe","release":"2021-12-20T09:03:05","revision":"0","sha1sum":"cbe9b0971f964250eee0233a1709a5300a93e60c","size":"4MB","target_guids":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"type_of_change":"1","version":"2.74"}],"id":{"product":"6c76dfc1e26441a48559e0f1bee2891e","version":"13640b09dbbc404785e09579da0c0e65"},"installation":{"command":"cpqsetup.exe","command_params":"/tD6020 /v2.74 /iTormore-Release-2.74-build-001.bin /lD6020.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":720,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong>&nbsp;&nbsp;</p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES:&nbsp;</strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong>&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f&nbsp;</strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"HPE D6020 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D6020","target_guid":"b99dfb74-f0bc-464f-b418-cd18f2a1a8e3","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-29T12:39:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>Temperature sensors logic inside gSEP model and SES database</li>\n\t<li>When an IOM is pulled the surviving IOM reports false critical temperatures</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v202690/20-D6020-Gen10RN274J_ED8.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D6020","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for Broadcom NetXtreme-E devices for Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントには、Microsoft Windows Server 2019用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1051328","datemodified":"2021-09-27T06:18:48","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp047541.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"dfe6bb8774b62e8f5fcd1742a4a04a67","name":"cp047541.exe","release":"2022-01-10T00:00:00","revision":"1","sha1sum":"3b7419cdd34fe38945ace9e23876170dbcab975d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"1","version":"219.0.44.0"}],"id":{"product":"d936b2fd4e0c4dcb9d5ef13b3d9dbd87","version":"1e3fbd6f953a438f9c12382a6f965930"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"Broadcom NetXtreme-Eドライバーfor Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41593","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41592","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41593","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41592","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41595","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41594","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41597","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41596","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41595","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41597","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41596","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D6","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41593","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41593","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41595","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41594","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41597","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41595","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41594","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41596","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"1806","subdev":"1751","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41751","type":"pci","ven":"14e4"},{"dev":"1809","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180914e41599","type":"pci","ven":"14e4"},{"dev":"1808","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180814e41598","type":"pci","ven":"14e4"},{"dev":"1804","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180414e41599","type":"pci","ven":"14e4"},{"dev":"1807","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180714e41599","type":"pci","ven":"14e4"},{"dev":"1806","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41598","type":"pci","ven":"14e4"},{"dev":"1808","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180814e41599","type":"pci","ven":"14e4"},{"dev":"1806","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180614e41599","type":"pci","ven":"14e4"},{"dev":"1809","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180914e41598","type":"pci","ven":"14e4"},{"dev":"1801","subdev":"1599","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180114e41599","type":"pci","ven":"14e4"},{"dev":"1801","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180114e41598","type":"pci","ven":"14e4"},{"dev":"1804","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180414e41598","type":"pci","ven":"14e4"},{"dev":"1807","subdev":"1598","subven":"14e4","target_guid":"a6b1a447-382a-5a4f-14e4-180714e41598","type":"pci","ven":"14e4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T06:10:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which System was unavailable to the create more then 32 &nbsp;Virtual Functions (VFs) per &nbsp;Virtual Functions (VFs)</li>\n\t<li>This product correct an issue which BSOD during heavy TX traffic.</li>\n\t<li>This product correct an issue which driver Initialization failure on Virtual functions</li>\n\t<li>This product correct an issue which BSOD after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which invalid link speed options on Base-T devices</li>\n\t<li>This product correct an issue which &nbsp;VF invalid on Windows virtual machines host</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which System was unavailable to the create more then 32 &nbsp;Virtual Functions (VFs) per &nbsp;Virtual Functions (VFs)</li>\n\t<li>This product correct an issue which BSOD during heavy TX traffic.</li>\n\t<li>This product correct an issue which driver Initialization failure on Virtual functions</li>\n\t<li>This product correct an issue which BSOD after updating the inbox driver on Windows 2019.</li>\n\t<li>This product correct an issue which invalid link speed options on Base-T devices</li>\n\t<li>This product correct an issue which &nbsp;VF invalid on Windows virtual machines host</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33588965","datemodified":"2022-02-21T12:46:07","file_list":["A46_2.56_02_10_2022.signed.flash","A46_2.56_02_10_2022.xml","payload.json"],"md5sum":"e2e57410dc74a23a0c49e4d50a840c07","name":"A46_2.56_02_10_2022.fwpkg","release":"2022-02-21T12:41:47","revision":"0","sha1sum":"b68a62236a72e5ba4c6d485b737564fd133b12df","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"17ae190412f049ff80b7f941eb9e3732","version":"9d2fb659406a4760b47df09b3238d9ed"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T17:19:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - I41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"I41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000206","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33602168","datemodified":"2022-03-08T10:08:57","file_list":["I41_2.62_03_08_2022.signed.flash","I41_2.62_03_08_2022.xml","payload.json"],"md5sum":"ed1529a87618807fb3e2191980883774","name":"I41_2.62_03_08_2022.fwpkg","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"cf7f95108940ae74bd513cbeb2b236cf86297133","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000206"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"65d759aa54bf415a9a190ccfb152d004","version":"5ea5d075ff5443b49dd89d7c99de4b71"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant BL460c Gen10 (I41) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:35:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"I41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"此套件包含公用程式和二進位檔，可在 Linux 作業系統上升級僅 HPE Mellanox 乙太網路配接卡韌體。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Linux Operating Systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 HPE Mellanox 이더넷 전용 어댑터 펌웨어를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"此软件包含有用于升级在Linux操作系统下运行的仅使用太网适配器的HPE Mellanox的固件所需的实用程序和二进制程序。"},{"lang":"ja","x_late":"このパッケージは、Linuxオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"8844803","datemodified":"2022-02-07T09:30:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/CP050366.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.16-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050366.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050366.scexe"],"md5sum":"5d86a9058a5c3c2695c356f1b660f944","name":"firmware-nic-mellanox-ethernet-only-1.0.16-1.1.x86_64.rpm","release":"2022-02-07T09:30:15","revision":"0","sha1sum":"d18098e34630469bd981b72045c7558c2c41d035","size":"8MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.16"}],"id":{"product":"5c045315a07d45779f552f6cb831a2b4","version":"d0a15cab2a914c3e89305b66ef172934"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"線上韌體升級公用程式 (Linux x86_64)，僅適用於 HPE Mellanox 乙太網路配接卡"},{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters"},{"lang":"ko","x_late":"HPE Mellanox 이더넷 전용 어댑터의 온라인 펌웨어 업그레이드 유틸리티(Linux x86_64)"},{"lang":"cn","x_late":"用于仅使用太网适配器的HPE Mellanox的在线固件升级实用程序（Linux x86_64）"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T10:54:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Updated mstflint from version 4.13 to 4.16</strong></p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)</li>\n\t<li>779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li>\n\t<li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following device has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEML","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46454d4c","Version":"HPD6"},{"DeviceName":"MB4000JFEMN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46454d4e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB2000JFEML and MB4000JFEMN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。MB2000JFEMLおよびMB4000JFEMN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><br />\n<strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5505846","datemodified":"2021-07-23T07:16:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/CP048159.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/HAKPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-624b75c7e2-HPD6-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048159.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048159.scexe"],"md5sum":"857760407781b70b7a45bb399317e2a1","name":"firmware-hdd-624b75c7e2-HPD6-8.1.x86_64.rpm","release":"2021-07-23T07:02:14","revision":"0","sha1sum":"1a195b480ede4685c5d879f21ae59a27d740670f","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46454d4c","002340a5-4d00-3442-3030-304a46454d4e"],"type_of_change":"2","version":"HPD6"}],"id":{"product":"e3c28d7e84d2418a888d50f48b760538","version":"55e1712e6d9b45b9add89108fb0afa52"},"installation":{"command":"CP040328.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEML and MB4000JFEMN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFEMLおよびMB4000JFEMNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000JFEML","target_guid":"002340a5-4d00-3242-3030-304a46454d4c","type":"sas"},{"id":"MB4000JFEMN","target_guid":"002340a5-4d00-3442-3030-304a46454d4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T15:33:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location. This issue was found during supplier ongoing reliability testing.</li>\n\t<li>The firmware also includes emergency power off improvements.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEMN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEML","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16958703","datemodified":"2021-08-27T07:25:42","file_list":["/CP048397_BUILD_2.data","/CP048397.vmexe","/CP048397.vmexe64","/CP048397.vmfile","/CP048397_VMw.zip","/CP048397.xml","/payload.json","/CP048397_VMw.zip/index.xml","/CP048397_VMw.zip/vendor-index.xml","/CP048397_VMw.zip/metadata.zip","/CP048397_VMw.zip/vib20/CP048397/HPE_bootbank_CP048397_HPD3.2-7.0.0.15843807.vib","/CP048397_VMw.zip/metadata.zip/vendor-index.xml","/CP048397_VMw.zip/metadata.zip/vmware.xml","/CP048397_VMw.zip/metadata.zip/vibs/CP048397--9205879085268121126.xml","/CP048397_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048397_HPD3.2-7.0.0.15843807.xml"],"md5sum":"ca4a64bb4bf915e8761407203db95de2","name":"CP048397.zip","release":"2021-08-27T07:20:12","revision":"0","sha1sum":"4d2ca6b2575422fca8735c46905402dbe121cf4d","size":"16MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048397","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"d7a820130b1346d2a8d4377d479232cf","version":"f5efc4476fb74e2e9d51d7755e922554"},"installation":{"command":"CP040692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T17:17:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEBHasseFG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB014000GWUDA Drive"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB014000GWUDAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWUDA Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6231414","datemodified":"2021-07-23T06:00:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/CP048142.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/HLEBHasseFG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG2-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048142.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048142.scexe"],"md5sum":"0a148a8c97c042ce1988d26e3d01555f","name":"firmware-hdd-41cdb1c9da-HPG2-5.1.x86_64.rpm","release":"2021-07-23T05:48:05","revision":"0","sha1sum":"9b305e83b7c1841887bc0a138d2cb288cf2739ee","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-304757554441"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"fc2945bc3e5744fea9d120a012546560","version":"dc734ac044fa4741be51ceeef8cb5432"},"installation":{"command":"CP041508.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWUDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWUDA","target_guid":"4d2340a5-3042-3431-3030-304757554441","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:15:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000GWUDA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U56_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33829544","datemodified":"2022-02-07T08:40:27","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/CP050654.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/U56_1.58_01_13_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u56-1.58_2022_01_13-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050654.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050654.scexe"],"md5sum":"e6397b21aff8c17e953b337f72e0bce3","name":"firmware-system-u56-1.58_2022_01_13-1.1.x86_64.rpm","release":"2022-02-07T08:34:04","revision":"0","sha1sum":"f5e6003d1db6393a087ab752f571ce38783b35ca","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000239"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"d04d5f721c2f4e7798db0b91a4b31687","version":"f0c9bd04bce1408992081be31c5559b8"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\nコマンドをする際に‘./hpsetup’とタイプすることにより、前のステップで見たディレクトリに変更し、hpsetupを実行できます。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE DL110 Gen10 Plus Telco（U56）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-03T06:56:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U56","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2921688","datemodified":"2021-07-24T07:29:05","file_list":["cp048452.xml","cpqsetup.exe","payload.json","setup.dll","T14SELD4.REL"],"md5sum":"0566462dbfb75a2e3a153405938873c3","name":"cp048452.exe","release":"2021-07-24T07:20:05","revision":"0","sha1sum":"ff668eb70abfe56f34bd539336de285ac01b137e","size":"2MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"62c5be0602154ae6afbf730b5a1cb394","version":"8a5a5206ba2446eea6762ad2acf3860d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T05:59:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U47_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34208840","datemodified":"2022-02-08T02:44:31","file_list":["cp050758.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U47_1.58_01_13_2022.signed.flash"],"md5sum":"f65ef8b660abb3a1f3e7744707b09e19","name":"cp050758.exe","release":"2022-02-08T02:41:55","revision":"0","sha1sum":"9a58f8ca28c38ff0ee9778e07be62259af38f735","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000227"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"6d1ce52e0d6c4c48a4cc6f903852d87d","version":"4ddb603b152a4ebb8c6649f72d41a5b2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47) "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1Uノードおよび2Uノード受注構成サーバー(U47) "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-07T18:11:27","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"U47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWFVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SErD3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57465642","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EG000300JWFVB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000300JWFVB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000300JWFVB Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16252392","datemodified":"2021-08-27T09:54:59","file_list":["/CP048245_BUILD_2.data","/CP048245.vmexe","/CP048245.vmexe64","/CP048245.vmfile","/CP048245_VMw.zip","/CP048245.xml","/payload.json","/CP048245_VMw.zip/index.xml","/CP048245_VMw.zip/vendor-index.xml","/CP048245_VMw.zip/metadata.zip","/CP048245_VMw.zip/vib20/CP048245/HPE_bootbank_CP048245_HPD3.2-7.0.0.15843807.vib","/CP048245_VMw.zip/metadata.zip/vendor-index.xml","/CP048245_VMw.zip/metadata.zip/vmware.xml","/CP048245_VMw.zip/metadata.zip/vibs/CP048245-2464200756205669878.xml","/CP048245_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048245_HPD3.2-7.0.0.15843807.xml"],"md5sum":"b87c13cd2045da4702e0e9fdd45e78da","name":"CP048245.zip","release":"2021-08-27T09:49:15","revision":"0","sha1sum":"65a2a4b2f4e346460abe3ea3efd53ad1f04c7704","size":"15MB","target_guids":["452340a5-3047-3030-3330-304a57465642"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048245","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"911c76d50a064e62be53550825c8db4d","version":"92aab0359c734a0aba2419175bfd1901"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000300JWFVB Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG000300JWFVBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG000300JWFVB","target_guid":"452340a5-3047-3030-3330-304a57465642","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T12:29:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG000300JWFVB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.02"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.02"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.19.02"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, UEFI, NCSI, iSCSI, FCoE, CCM and L2 code running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、PXE、UEFI、NCSI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"22981980","datemodified":"2021-12-21T08:12:32","file_list":["/CP050210_BUILD_10.data","/CP050210.vmexe","/CP050210.vmexe64","/CP050210.vmfile","/CP050210_VMw.zip","/CP050210.xml","/payload.json","/CP050210_VMw.zip/index.xml","/CP050210_VMw.zip/vendor-index.xml","/CP050210_VMw.zip/CP050210-build-metadata.zip","/CP050210_VMw.zip/vib20/CP050210/HPE_bootbank_CP050210_1.30.2.10-7.0.0.15843807.vib","/CP050210_VMw.zip/CP050210-build-metadata.zip/vendor-index.xml","/CP050210_VMw.zip/CP050210-build-metadata.zip/vmware.xml","/CP050210_VMw.zip/CP050210-build-metadata.zip/vibs/CP050210--2952195694772506008.xml","/CP050210_VMw.zip/CP050210-build-metadata.zip/bulletins/Smart-Component-CP050210_1.30.2.10-7.0.0.15843807.xml"],"md5sum":"834ffe89a5dd293fe952570bcf37d5b0","name":"CP050210.zip","release":"2021-12-21T08:05:16","revision":"0","sha1sum":"de3ba3b9953ee8a5f07c297284a5a804d4f44249","size":"21MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"1.30.2","vib_list":[{"name":"CP050210","version":"1.30.2.10-7.0.0.15843807"}]}],"id":{"product":"03d55b6f216746b88ddef311b0a8c1f9","version":"3822a1e32e4b4519a8ab5e29416bd7f6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<li>VMwareコンポーネントをインストールします。\n\t<ul>\n\t\t<li>a. ESXi 7.0ターゲットの場合：esxcli software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<li>b. ESXi 6.xターゲットの場合：esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ul>\n\t</li>\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ul>\n\t\t<li>a. /opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<li>b. Smartコンポーネントをクリーンアップするには：\n\t\t<ul>\n\t\t\t<li>i. ESXi 7.0ターゲットの場合：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii. ESXi 6.xターゲットの場合：esxcli software vib remove –n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c. CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE QLogic NX2 上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE QLogic NX2在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T07:37:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that memory usage when more than one adapters</li>\n\t<li>This product now supports VMware ESXi 7.0 u3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 12 64-bit to enable the HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a controller. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE MR416i-p、MR416i-a、MR216i-p、MR216i-aコントローラーを有効にする、64ビットSUSE LINUX Enterprise Server 12用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"734885","datemodified":"2021-10-05T11:27:16","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"5b87e638641166c5251d44e7a2845e45","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles12sp4-1.x86_64.rpm","release":"2021-10-05T11:19:09","revision":"0","sha1sum":"fd7cb359286bcd7e80023f8f3b9de1b9b217e8de","size":"717KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"741755","datemodified":"2021-10-05T11:30:40","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"cd7718da252b8aa265f55f94aee4e946","name":"lsi-megaraid_sas-kmp-default-07.716.02.00_sles12sp5-1.x86_64.rpm","release":"2021-10-05T11:19:09","revision":"0","sha1sum":"83469ca2d967cb4a22d094241b3729faa68ed072","size":"724KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"849f086e086c48be8b248502b935c97a","version":"94c4128766fc4667b15cc2034f81f40a"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles12spX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、spXはOSアップデート番号を表します）<br />\n<br />\nセットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a controller Driver for 64-bit SUSE LINUX Enterprise Server 12"},{"lang":"ja","x_late":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-aコントローラードライバーfor 64-bit SUSE LINUX Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T10:12:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for DL20 Gen10 Plus Server.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR100/Ethernet 100Gb 1ポートMCX653105A-ECAT QSFP56 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter(P23665-B21)</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000452</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下のファームウェアバージョンが含まれています。</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernetアダプター専用</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1ポートMCX653105A-ECAT QSFP56 x16アダプター（P23665-B21）</td>\n\t\t\t<td>20.31.1014</td>\n\t\t\t<td>MT_0000000452</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p> </p>\n"}],"files":[{"bytes":"5951992","datemodified":"2021-12-07T09:46:40","file_list":["20_32_1010-MCX653105A-ECA_HPE_Ax.pldm.signed","20_32_1010-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"e8b5192b7a89e1896ae0b8fbcd379287","name":"20_32_1010-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:43:41","revision":"0","sha1sum":"c7bc748fc044d4d15184e3057bf4edd7e583b15a","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"cca7377cd12644cab41f5bd7e94cc2bd","version":"ca0abc22e7284e809750886c5195c65f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR100/Ethernet 100Gb 1ポートMCX653105A-ECAT QSFP56 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWTFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57544644","Version":"HPD8"},{"DeviceName":"MB012000JWTFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07scHPD8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57544643","Version":"HPD8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000JWTFD and MB012000JWTFC"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB014000JWTFDおよびMB012000JWTFC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;-&nbsp;MB014000JWTFD and MB012000JWTFC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"4895220","datemodified":"2021-08-13T12:10:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/CP049121.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/TAMG07scHPD8.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4ba9615f90-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049121.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049121.scexe"],"md5sum":"b4d22e7bf5f05b112be9a145312bc836","name":"firmware-hdd-4ba9615f90-HPD8-2.1.x86_64.rpm","release":"2021-08-13T11:57:12","revision":"0","sha1sum":"bd7c1939454e5877a13ed0cfd9ba6d51886df12b","size":"4MB","target_guids":["4d2340a5-3042-3431-3030-304a57544644","4d2340a5-3042-3231-3030-304a57544643"],"type_of_change":"1","version":"HPD8"}],"id":{"product":"d2753039facd45788d8eb7892e214eed","version":"a728c8202ae448589c8ce0ced9652da9"},"installation":{"command":"CP040352.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWTFD and MB012000JWTFC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000JWTFDおよびMB012000JWTFCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000JWTFD","target_guid":"4d2340a5-3042-3431-3030-304a57544644","type":"sas"},{"id":"MB012000JWTFC","target_guid":"4d2340a5-3042-3231-3030-304a57544643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T12:31:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB014000JWTFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWTFC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.2006"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872723-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872725-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading firmware on HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (HPE Part# 843400-B21), HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (HPE Part# 872723-B21), HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part# 872725-B21) on Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>InfiniBand Card Type</td>\n\t\t\t<td>Firmware&nbsp;Version</td>\n\t\t\t<td>PSID</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter (843400-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>\n\t\t\t<p>HPE2920111032</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter (872723-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (872725-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000008</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"7507262","datemodified":"2022-02-02T13:01:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/CP050408.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw/fw-ConnectX4-rel-12_28_2006-843400-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-872723-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-872725-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050408.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050408.scexe"],"md5sum":"d1a81be5f5f80ab8a80d2296aaa11815","name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.9-1.1.x86_64.rpm","release":"2022-02-02T13:00:37","revision":"0","sha1sum":"7abbf3a214bd4c18e89770b41eb53b88a44efc24","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"type_of_change":"1","version":"1.0.9"}],"id":{"product":"f148b53c7b96447699a0d01706827644","version":"3fecdfa42e87429e9199e9f913fd443c"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00EF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000ef","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0257","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900257","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0255","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900255","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T05:04:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p style=\"margin-left:40px\">843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n&nbsp;</p>\n\n<ul>\n</ul>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)<br />\n872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>843400-B21 (HPE Apollo A10 InfiniBand EDR (100Gb) 2-port Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>872723-B21 (HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter)</li>\n\t<li>872725-B21 (HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that caused the DCR (DC Resources) to be destroyed before the retry option managed to work when the retry timeout is too big. in this case, the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed an&nbsp;issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_IB_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含適用於在 Red Hat Enterprise Linux 7 x86_64 下執行之 HPE Broadcom 乙太網路網路卡的驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Broadcom Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 5 x86_64에서 실행 중인 HPE Broadcom 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Broadcom 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Broadcom Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"118472","datemodified":"2021-01-17T07:09:51","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1127.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"2e577aa848e57982fa2a1cc9fba319e1","name":"kmod-tg3-3.139b-1.rhel7u8.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"9ffb3913d1b2bde21868351d38269c6db68d30d5","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"},{"bytes":"118475","datemodified":"2021-01-17T07:07:50","file_list":["./etc/depmod.d/tg3.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3","./lib/modules/3.10.0-1160.el7.x86_64/extra/tg3/tg3.ko","./usr/share/smartupdate/kmod-tg3/component.xml"],"md5sum":"6b00b8e8dc8a92bfba2faae68af7d6ef","name":"kmod-tg3-3.139b-1.rhel7u9.x86_64.rpm","release":"2021-01-17T07:02:05","revision":"0","sha1sum":"233f44987be805e24559a094415ff1256682977f","size":"115KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"type_of_change":"0","version":"3.139b-1"}],"id":{"product":"f4e486fae98c4ecea1e8d2f80f412bb9","version":"bf80ddf91812427facda6e8e5dfdcc45"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 Ethernet 驅動程式"},{"lang":"en","x_late":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 5 x86_64용 HPE Broadcom tg3 이더넷 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Broadcom tg3 以太网驱动程序"},{"lang":"ja","x_late":"HPE Broadcom tg3 Ethernetドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 Update 8.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7 update 9</p>\n","curr_fixes_x_late":"<p>The products fixes an a race condition issue where driver will still try to access the PHY(physical layer) although it was already brought down when the tg3 timer fires</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"},{"name":"kmod-tg3","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel Gigabit 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel 기가비트 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel 千兆以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3106435","datemodified":"2021-11-05T02:57:51","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-igb","./lib/modules/4.12.14-120-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"67d86abd21ffbcae2e34bf357c9af6f6","name":"hp-igb-kmp-default-6.8.5_k4.12.14_120-2.sles12sp5.x86_64.rpm","release":"2021-11-05T02:51:05","revision":"0","sha1sum":"8b2567d8d86b9a178c854080a4bcf765a3b97833","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"1","version":"6.8.5-2"}],"id":{"product":"5049ff108a414cae906f3f80d242a819","version":"5f5d218bda1b451981828a43f5d78d46"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驅動程式"},{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel igb 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel igb 驱动程序 "},{"lang":"ja","x_late":"HPE Intel igbドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-05T01:47:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Linux Firmware upgrade utility v.1.22.5</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Fibre Channel-Host Bus Adapter driver support for HPE storage arrays. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1623736","datemodified":"2021-08-26T10:52:46","file_list":["cp046828.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"a74460a28d687d8657232f8c2d979186","name":"cp046828.exe","release":"2021-08-26T10:50:06","revision":"0","sha1sum":"4147785255e563388b71ceeeccfb18002aa6f533","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"228e6aefb0ce46a0a7e230319e326d29","version":"0ee6710d070c431dab5a1e637e7a4ef4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to version 9.4.2.20</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where Hyper-V Virtual Machines (VMs) may not see all paths to Logical Unit Numbers (LUNs)</li>\n\t<li>Fixed a behavior where an Fibre Channel (FC) Tape device configured for Target Persistent Binding would not be recognized after server reboot</li>\n\t<li>Fixed a behavior where Multipath I/O (MPIO) paths may not recover if left offline for more than 90 seconds</li>\n\t<li>Fixed a behavior where Input/Output (I/O) incompletions would be reported after extended periods of uptime in an Fibre Channel (FC) fabric doing Remote Desktop Protocol (RDP) requests</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version 9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This product includes HPONCFG, BOOTCFG, TESTEVENT, CONREP, and the Smart Storage Array Command Line Interface (SSACLI) utilities for configuration of servers. HPONCFG can be used to set up and reconfigure the iLO (Integrated Lights-Out) management controller of a server. BOOTCFG can be used to set up the boot configuration for the server. SSACLI can be used in the configuration of HPE Smart Array controllers and attached storage. The TESTEVENT utility generates test WBEM indication and test SNMP trap. The CONREP Utility enables server hardware configuration capture, set and duplication. "},{"lang":"ja","x_late":"この製品には、HPONCFG、BOOTCFG、TESTEVENT、CONREP、およびサーバーを構成するためのSmart Storage Array Command Line Interface (SSACLI)ユーティリティーが含まれています。HPONCFGは、サーバーのiLO(Integrated Lights-Out)マネジメントコントローラーの設定、再構成に使用できます。BOOTCFGはサーバーの起動構成を設定するために使用できます。SSACLIは、HPE Smartアレイコントローラーと接続されたストレージの構成に使用できます。TESTEVENTユーティリティはテストWBEMイベントとテストSNMPトラップを作ります。CONREPユーティリティは、サーバーハードウェア構成のキャプチャー、設定、そして複製を可能にします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11015223","datemodified":"2021-09-14T14:30:01","file_list":["/cp047458.xml","/HPE-Utility-Component_10.8.0.650-26.zip","/HPE-Utility-Component_10.8.0.650-26.zip/index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip","/HPE-Utility-Component_10.8.0.650-26.zip/hponcfg-6.0.0.5.5-0.37.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/bootcfg-6.0.0.02-06.00.16.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/conrep_650.10.8.0.12-6.5.0.2494585.vib","/HPE-Utility-Component_10.8.0.650-26.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/MIS_bootbank_hpessacli_5.20.8.0-6.5.0.4240417.oem.vib","/HPE-Utility-Component_10.8.0.650-26.zip/ilo_650.10.7.5.2-1OEM.650.0.0.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/testevent-6.5.0.02-01.00.9.4240417.vib","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vendor-index.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vmware.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/hponcfg-1881737420209856034.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/bootcfg-1749855250648854147.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/conrep-6078124524435142414.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/cru-6087260586819000143.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/hpessacli--6978747662280214123.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/ilo-5995240362405261046.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/vibs/testevent--766157199079035683.xml","/HPE-Utility-Component_10.8.0.650-26.zip/metadata-HPE-Utility-Component_10.8.0.650-26.zip/bulletins/esxi6.5-util-bundle-10.8.0.650-26.xml"],"md5sum":"ed1fe91460510ad2e179452f325a31dd","name":"cp047458.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"87f55c6b50c8d015312a264db36731c664053d63","size":"10MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8","20a6e8e4-bf33-4c71-a6bf-d9ec8013c1b6","20a6e8e4-bf33-4c71-a6bf-d9ec0e2e459f","20a6e8e4-bf33-4c71-a6bf-d9ec23d0c2b9","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecf25c12c9"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"hponcfg","version":"6.0.0.5.5-0.37.2494585"},{"name":"bootcfg","version":"6.0.0.02-06.00.16.2494585"},{"name":"conrep","version":"650.10.8.0.12-6.5.0.2494585"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"},{"name":"hpessacli","version":"5.20.8.0-6.5.0.4240417.oem"},{"name":"ilo","version":"650.10.7.5.2-1OEM.650.0.0.4240417"},{"name":"testevent","version":"6.5.0.02-01.00.9.4240417"}]}],"id":{"product":"161a304825cb434e83dc121e59667140","version":"645d8072dfd546f395eb08a1887bd72a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとして更新対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>オフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Utilities Bundle Smart Component for ESXi 6.5 "},{"lang":"ja","x_late":"HPE ユーティリティ バンドルSmartコンポーネント for ESXi 6.5 "}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T22:36:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","curr_fixes_x_late":"<p>hpessacli</p>\n\n<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hponcfg:6.0.0.5.5-0.37.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"testevent:6.5.0.02-01.00.9.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"conrep:650.10.8.0.12-6.5.0.2494585","sw_key_expectedpath":"software:vmware:zip"},{"name":"hpessacli:5.20.8.0-6.5.0.4240417.oem","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:650.10.7.5.2-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bootcfg:6.0.0.02-06.00.16.2494585","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online HDD/SSD&nbsp;Flash Component for VMware ESXi - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17022592","datemodified":"2021-08-26T20:41:18","file_list":["/CP048372_BUILD_2.data","/CP048372.vmexe","/CP048372.vmexe64","/CP048372.vmfile","/CP048372_VMw.zip","/CP048372.xml","/payload.json","/CP048372_VMw.zip/index.xml","/CP048372_VMw.zip/vendor-index.xml","/CP048372_VMw.zip/metadata.zip","/CP048372_VMw.zip/vib20/CP048372/HPE_bootbank_CP048372_HPG2.2-7.0.0.15843807.vib","/CP048372_VMw.zip/metadata.zip/vendor-index.xml","/CP048372_VMw.zip/metadata.zip/vmware.xml","/CP048372_VMw.zip/metadata.zip/vibs/CP048372--3640455688668061355.xml","/CP048372_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048372_HPG2.2-7.0.0.15843807.xml"],"md5sum":"531614f4da7f153f09d72fff0fe4072f","name":"CP048372.zip","release":"2021-08-26T20:36:37","revision":"0","sha1sum":"73ba20af0d796aed76eed4fc9dad6e7bbdb3bb8c","size":"16MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP048372","version":"HPG2.2-7.0.0.15843807"}]}],"id":{"product":"543d676d322b4e8ab4ce97b5bffa1a41","version":"2d42e6fead3c4febb97a347f291efd92"},"installation":{"command":"CP040549.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T21:26:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"22503440","datemodified":"2022-02-09T21:13:42","file_list":["cp050380.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"8ddf57f3000be62bad19e07e953b12c9","name":"cp050380.exe","release":"2022-02-09T12:24:15","revision":"0","sha1sum":"75a38542ea1b9567a43e832e08855433c77c6a1f","size":"21MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.0.11"}],"id":{"product":"cdfe3840d6074900a4d11b774d3e5307","version":"9e7b85c26616493d8101f78330fea77f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T06:46:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1200:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>&nbsp;&nbsp;Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and&nbsp;&nbsp;the DQPN.</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). <strong>Note:</strong> If the port does not go up, switch to Force mode.</li>\n</ul>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li>\n\t<li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li>\n\t<li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New Features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixes an issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed n issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18558580","datemodified":"2021-08-26T12:59:44","file_list":["/CP048335_BUILD_2.data","/CP048335.vmexe","/CP048335.vmexe64","/CP048335.vmfile","/CP048335_VMw.zip","/CP048335.xml","/payload.json","/CP048335_VMw.zip/index.xml","/CP048335_VMw.zip/vendor-index.xml","/CP048335_VMw.zip/metadata.zip","/CP048335_VMw.zip/vib20/CP048335/HPE_bootbank_CP048335_HPG3.2-7.0.0.15843807.vib","/CP048335_VMw.zip/metadata.zip/vendor-index.xml","/CP048335_VMw.zip/metadata.zip/vmware.xml","/CP048335_VMw.zip/metadata.zip/vibs/CP048335-3368829359354883197.xml","/CP048335_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048335_HPG3.2-7.0.0.15843807.xml"],"md5sum":"f481ed1916a806848a557b7ac092c6c1","name":"CP048335.zip","release":"2021-08-26T12:54:40","revision":"0","sha1sum":"e8dadd74495f2b377ad630d4451315b4c2f4fe5c","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048335","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"6973afa059034a93b5842e17d11d1b46","version":"0ad78e0db597495a989eafc1c0f5c16b"},"installation":{"command":"CP042747.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T20:05:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33603030","datemodified":"2022-03-08T11:11:00","file_list":["payload.json","U32_2.62_03_08_2022.signed.flash","U32_2.62_03_08_2022.xml"],"md5sum":"08327f2ea29c0b7b841eb17e38e82114","name":"U32_2.62_03_08_2022.fwpkg","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"519b912bc7871f316047dc74ee655b65a4a794e2","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"7db6f792355b49a58fc4f82d6bbbdd99","version":"67efaaad5d1a4b5080776bf3d0125924"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL360 Gen10（U32）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:22","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Emulex 10/20GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5上で動作するHPE Emulex 10/20GbEサーバーアダプターのためのiSCSIドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1108.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1108.0が含まれています。</p>\n"}],"files":[{"bytes":"3343325","datemodified":"2020-06-11T04:21:05","file_list":["/cp044543.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/elxiscsi-12.0.1108.0-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/ELX-ESX-libelxima.so-12.0.1108.0.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/README.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/doc/release_note_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elx-esx-libelxima.so/ELX_bootbank_elx-esx-libelxima.so_12.0.1108.0-03.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1108.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elx-esx-libelxima.so--741715821.xml","/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-8109809.zip/VMW-ESX-6.5.0-elxiscsi-12.0.1108.0-offline_bundle-8109809.zip/metadata.zip/vibs/elxiscsi--787023163.xml"],"md5sum":"69d45074ffc53654621999495e48e277","name":"cp044543.zip","release":"2020-06-11T04:20:05","revision":"0","sha1sum":"66e2c3ea4389eac2e20d962051e094899220d657","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ec1c488a85"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elx-esx-libelxima.so","version":"12.0.1108.0-03"},{"name":"elxiscsi","version":"12.0.1108.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"21671a6ff3c64fa1be71c992a0903728","version":"bafcd3494cbc44a3bf3b9aaa241ffacf"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSIドライバーfor VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue ESXi lib naming convention in iscsi driver packages caused payload conflict for ESXi 6.5.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1108.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima.so:12.0.1108.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 8."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"519463","datemodified":"2021-08-24T16:07:47","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/ice","./lib/modules/4.18.0-240.el8.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/a627ce37127644cbd025ed9d3a368af8a4d254","./usr/share/smartupdate/kmod-ice/component.xml"],"md5sum":"41cbdebf478ba10472b2fad42776bf97","name":"kmod-ice-1.6.4-1.rhel8u3.x86_64.rpm","release":"2021-08-24T15:59:05","revision":"0","sha1sum":"a3bc32ab56ecd00774b7a3c584a7880788f709dc","size":"507KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.6.4-1"},{"bytes":"519916","datemodified":"2021-08-24T16:09:08","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/ice","./lib/modules/4.18.0-305.el8.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/27","./usr/lib/.build-id/27/0920decb1be9a35926d99a56b6ed3b5d46505f","./usr/share/smartupdate/kmod-ice/component.xml"],"md5sum":"cd676d4f80791767fb10ac3b8821066d","name":"kmod-ice-1.6.4-1.rhel8u4.x86_64.rpm","release":"2021-08-24T15:59:05","revision":"0","sha1sum":"abbe1b7ae2a2bdd03bf2f90447fa1aa73274bb62","size":"507KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.6.4-1"}],"id":{"product":"2c8de2e408714be7a3117529d7da4ca9","version":"b63589c32c904940ab3d56214370e419"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel ice Drivers for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD7"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXe0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPK and EH000600JWHPH"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPK および EH000600JWHPH ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EH000900JWHPK and EH000600JWHPH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added supported for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3000720","datemodified":"2021-07-26T17:31:47","file_list":["cp049134.xml","cpqsetup.exe","payload.json","setup.dll","TA14SXe0HPD7.REL"],"md5sum":"75d6509bb11e2ef75d097f33f0470d45","name":"cp049134.exe","release":"2021-07-26T17:24:06","revision":"0","sha1sum":"f09b256d0b1637db8f36d434b746b7a2a430091e","size":"2MB","target_guids":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"7e6f42aebfdb4390968da43b36518880","version":"b837b9dbcf8946ff960a9920c71e5b88"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EH000900JWHPKおよびEH000600JWHPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH000600JWHPH","target_guid":"452340a5-3048-3030-3630-304a57485048","type":"sas"},{"id":"EH000900JWHPK","target_guid":"452340a5-3048-3030-3930-304a5748504b","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T17:19:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added supported for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000600JWHPH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWHPK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4202166","datemodified":"2021-03-08T20:09:31","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbe","./lib/modules/4.12.14-195-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"5bb6365255c19eea87674f7548864bff","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"7884b01cc5e342e777142e26358d84f6d428dd9d","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4991622","datemodified":"2021-03-08T20:10:55","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbe","./lib/modules/5.3.18-22-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"d2d5089730ce54447d91283791a01f40","name":"hp-ixgbe_bl-kmp-default-5.9.4_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:08","revision":"0","sha1sum":"5580ad40a933fa32894fcf1ec7d2922156b2b3ff","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"89efa5dd7c1545c0ad8e16f58fcdfeb6","version":"9c22c5cc997d4b678633ba92b3bb24f1"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Intel i40e Ethernet NICs running under Red Hat Enterprise Linux 8."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 8で動作するHPE Intel i40e Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"298629","datemodified":"2021-11-04T08:39:56","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-240.el8.x86_64","./lib/modules/4.18.0-240.el8.x86_64/extra","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-240.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/5a196f1e1a25f491deda272ea3df5b65c9cc6e","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"a8d4e256647f08c4b88820c1da74f99f","name":"kmod-hp-i40e-2.17.4-1.rhel8u3.x86_64.rpm","release":"2021-11-04T08:27:36","revision":"0","sha1sum":"2f54abb6277cbe51e78a01a2cd3458a2f54426e8","size":"291KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.17.4-1"},{"bytes":"299075","datemodified":"2021-11-04T08:35:45","file_list":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-i40e","./lib/modules/4.18.0-305.el8.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/851b97376a664476ee60ed4e48d222eec5a0df","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"md5sum":"0eabc5213d910cb4cad8d7a170e82a52","name":"kmod-hp-i40e-2.17.4-1.rhel8u4.x86_64.rpm","release":"2021-11-04T08:27:36","revision":"0","sha1sum":"17bd8195763a261dd44adda95a0b1a817201b911","size":"292KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"type_of_change":"1","version":"2.17.4-1"}],"id":{"product":"79178f63311141b49420306fd1de47d3","version":"089d4a409db24098a71471fa2aa667d9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 8"},{"lang":"ja","x_late":"HPE Intel i40eドライバー for Red Hat Enterprise Linux 8"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where double count in crc_error and size_error counter.</li>\n\t<li>This product addresses an issue where ethtool status triggers a warning due to invalid size on veb_tc when veb-stats was enabled.</li>\n\t<li>This product addresses an issue where the kernel error message about PF reset failed.</li>\n\t<li>This product addresses an issue where the adapter LED is not blinking via ethtool command</li>\n\t<li>This product addresses an issue where physical functions cannot synchronize tpid setting</li>\n\t<li>This product addresses an issue where Linux kernel problem (kernel Oops) when Virtual Station Interface (VSI) reset.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-i40e","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Windowsオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15531936","datemodified":"2022-02-07T09:51:36","file_list":["cp050390.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"96c7e58a55b59ddb9352b0ec59e0f92c","name":"cp050390.exe","release":"2022-02-07T09:50:38","revision":"0","sha1sum":"00993b67e25a455886af761922cb6e39b6661ece","size":"14MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.0.6"}],"id":{"product":"17666522baed46e695f28d4315d6fdb8","version":"4af7c77ca89847da9811b220aaa924c7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n [インストール]ボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Windows x64）"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T08:48:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.31.1014:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"ET000750KWJTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3054-3030-3735-304b574a5446","Version":"4ICSHPK4"},{"DeviceName":"EO000375KWJUC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3337-354b574a5543","Version":"4ICSHPK4"},{"DeviceName":"EO000750KWTXC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICSHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3735-304b57545843","Version":"4ICSHPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: ET000750KWJTF, EO000750KWTXC and EO000375KWJUC"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Previous Version of Firmware:&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; 4ICSHPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp;None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15833501","datemodified":"2021-08-27T09:24:59","file_list":["/CP048513_BUILD_2.data","/CP048513.vmexe","/CP048513.vmexe64","/CP048513.vmfile","/CP048513_VMw.zip","/CP048513.xml","/payload.json","/CP048513_VMw.zip/index.xml","/CP048513_VMw.zip/vendor-index.xml","/CP048513_VMw.zip/metadata.zip","/CP048513_VMw.zip/vib20/CP048513/HPE_bootbank_CP048513_4ICSHPK4.2-7.0.0.15843807.vib","/CP048513_VMw.zip/metadata.zip/vendor-index.xml","/CP048513_VMw.zip/metadata.zip/vmware.xml","/CP048513_VMw.zip/metadata.zip/vibs/CP048513-6652579536536410431.xml","/CP048513_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048513_4ICSHPK4.2-7.0.0.15843807.xml"],"md5sum":"cce79b019f1a9f6793db36fa5ee578a3","name":"CP048513.zip","release":"2021-08-27T09:19:48","revision":"0","sha1sum":"3a26d093f2dca9c849f95a00605d12b2bd4003de","size":"15MB","target_guids":["452340a5-3054-3030-3735-304b574a5446","452340a5-304f-3030-3337-354b574a5543","452340a5-304f-3030-3735-304b57545843"],"type_of_change":"1","version":"4ICSHPK4","vib_list":[{"name":"CP048513","version":"4ICSHPK4.2-7.0.0.15843807"}]}],"id":{"product":"f09974e786ab4852855854b483956c19","version":"40e72cc1ea4748ba926cb4c822f9c153"},"installation":{"command":"CP042960.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例: ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - ET000750KWJTF, EO000750KWTXC and EO000375KWJUC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - ET000750KWJTF、EO000750KWTXC、およびEO000375KWJUCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"ET000750KWJTF","target_guid":"452340a5-3054-3030-3735-304b574a5446","type":"nvme"},{"id":"EO000375KWJUC","target_guid":"452340a5-304f-3030-3337-354b574a5543","type":"nvme"},{"id":"EO000750KWTXC","target_guid":"452340a5-304f-3030-3735-304b57545843","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T09:25:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed HPK3 drive reports incorrect Device ID issue.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000375KWJUC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"EO000750KWTXC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"ET000750KWJTF","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4292520","datemodified":"2021-07-23T18:24:55","file_list":["cp048674.xml","cpqsetup.exe","HVLAeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"792d618f1260850671aa6daab4dd7d6b","name":"cp048674.exe","release":"2021-07-23T18:17:10","revision":"0","sha1sum":"1573c19909f4b2946646bdb5d6efd820ed82dc85","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"4fd1e8e4a27347cd8d83d1e63d9eb38e","version":"d36fe0fd23234446ac6b0deb81dcd353"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000GWKGRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:42:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHssseFD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB012000JWDFD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB012000JWDFD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000JWDFD Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18512086","datemodified":"2021-08-27T08:51:23","file_list":["/CP048404_BUILD_2.data","/CP048404.vmexe","/CP048404.vmexe64","/CP048404.vmfile","/CP048404_VMw.zip","/CP048404.xml","/payload.json","/CP048404_VMw.zip/index.xml","/CP048404_VMw.zip/vendor-index.xml","/CP048404_VMw.zip/metadata.zip","/CP048404_VMw.zip/vib20/CP048404/HPE_bootbank_CP048404_HPD3.2-7.0.0.15843807.vib","/CP048404_VMw.zip/metadata.zip/vendor-index.xml","/CP048404_VMw.zip/metadata.zip/vmware.xml","/CP048404_VMw.zip/metadata.zip/vibs/CP048404-2380168779059635809.xml","/CP048404_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048404_HPD3.2-7.0.0.15843807.xml"],"md5sum":"66961f8c0598cab8637b931aa303a766","name":"CP048404.zip","release":"2021-08-27T08:45:54","revision":"0","sha1sum":"bcd3b46a58d2877fd3ff9ec5e107193d06410b80","size":"17MB","target_guids":["4d2340a5-3042-3231-3030-304a57444644"],"type_of_change":"1","version":"HPD3","vib_list":[{"name":"CP048404","version":"HPD3.2-7.0.0.15843807"}]}],"id":{"product":"72ce2dc2a1214941a11d7ccaace19196","version":"9e3fa16a29f34288bd98e5691db27710"},"installation":{"command":"CP040682.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000JWDFDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB012000JWDFD","target_guid":"4d2340a5-3042-3231-3030-304a57444644","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:05:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000JWDFD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"26_32_1010-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE&nbsp; (P42041-B21)</td>\n\t\t\t<td>26.32.1010</td>\n\t\t\t<td>MT_0000000551</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"6422654","datemodified":"2021-12-07T10:23:39","file_list":["26_32_1010-MCX631432AS-ADA_Ax.pldm.signed","26_32_1010-MCX631432AS-ADA_Ax.pldm.xml","payload.json"],"md5sum":"086f1cf60c653c5427f7fff25cb6c6bb","name":"26_32_1010-MCX631432AS-ADA_Ax.pldm.fwpkg","release":"2021-12-07T10:20:33","revision":"0","sha1sum":"de336051454b1bb88c79e29267ba1338705e3062","size":"6MB","target_guids":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"type_of_change":"1","version":"26.32.1010"}],"id":{"product":"27053985f2354572a6633cc6a63bb7ef","version":"b36961579c8d460885305c3a1bb51f36"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New Features and Changes in Version 26.31.2006:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 26.31.2006:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n"},{"curr_enhancements_x_late":"<p><strong>New Features and Changes in Version 26.32.1010:</strong></p>\n\n<p>Added support for following features:</p>\n\n<ul>\n\t<li>LinkX module burning via MFT toolset. The new capability enables direct firmware burning from the internal flash storage to reduce the bandwidth and accelerate the burning process, including burning several modules at a time.</li>\n\t<li>An option to allow applications to build their own QoS tree over the NIC hierarchy by connecting QPs to responder/requestor Queue Groups.</li>\n\t<li>Improved NRZ link performance (RX algorithm).</li>\n\t<li>Improved NRZ link-up time (25G\\50G\\100G speeds).</li>\n\t<li>Enabled the options to control different Tx sets for the same attribute when connecting a Mellanox-Mellanox vs Mellanox to 3rd party HCA.</li>\n\t<li>&quot;InfiniBand&quot; properties set to the Network Device Function Redfish object.</li>\n\t<li>Direct Packet Placement (DPP): DPP is a receive side transport service in which the Ethernet packets are scattered to the memory according to a packet sequence number (PSN) carried by the packet, and not by their arrival order.</li>\n\t<li>To enable DPP offload, the software should create a special RQ by using the CREATE_RQ command, and set DPP relevant attributes.</li>\n\t<li>Added trust level for VFs. Once the VF is trusted, it will get a set of trusted capabilities.</li>\n\t<li>UCX can now enable AR by exposing Out-Of-Ordering bitmask per SL with &quot;ooo_per_sl&quot; field in the HCA_VPORT context. It can be also queried by running the QUERY_HCA_VPORT_CONTEXT command.</li>\n\t<li>Enhanced IB Congestion Control to support lower minimum rate. Now it uses destination-lid to classify flows to handle larger scale, and achieve better results in GPCNeT benchmark.</li>\n\t<li>Hardware steering dump output used for debugging and troubleshooting.</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 26.32.1010:</strong></p>\n\n<ol>\n\t<li>Changed the default value of DCQCN&#39;s (Data center- Quantized Congestion Notification) NP parameter min_time_between_cnps to 4 on all devices to support larger scalability of cluster.</li>\n\t<li>An issue that prevented VXLAN packets with svlan/cvlan tag from being matched.</li>\n\t<li>The eth_wqe_too_small counter to count ODP (On-Demand Paging) page used to fail.</li>\n\t<li>An issue related to raising 100GbE link on ConnectX-6 VPI 100Gb/s adapter cards.</li>\n\t<li>When MKEY_BY_NAME was enabled by NVCONFIG and a large number of VFs are configured, VM restart (VF/PF FLR) will take longer than when MKEY_BY_NAME is disabled.</li>\n\t<li>Low performance occurred after enabling the RoCE Accelerator capability.</li>\n\t<li>On rare cases, a fatal error related to errors from the PCI transport layer might be reported during FLR.</li>\n</ol>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX631432AS-ADAI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1931981","datemodified":"2021-11-02T19:51:15","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"1aec0dfe5c12ad9ec41da4432fef05b6","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.sles12sp4.x86_64.rpm","release":"2021-11-02T18:32:05","revision":"0","sha1sum":"664b3c5db4930246ee9ba3ea43796163efb25a48","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"1921574","datemodified":"2021-11-02T19:54:14","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/compat","./lib/modules/4.12.14-94.41-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-94.41-default/updates/drivers","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-94.41-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-94.41-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target","./lib/modules/4.12.14-94.41-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net","./lib/modules/4.12.14-94.41-default/updates/net/9p","./lib/modules/4.12.14-94.41-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/rds","./lib/modules/4.12.14-94.41-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-94.41-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"7912f1e39324e05fd48a0a536091379b","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.4.0.8.1.sles12sp4.x86_64.rpm","release":"2021-11-02T18:32:05","revision":"0","sha1sum":"f197cde820a2e34860401f78358e1fd0283f12ff","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"eff3fb3bc296490cb954337b0cfc0052","version":"248b89921a364c21a6ecd9bf93d68c12"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-94.41-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"},{"lang":"ja","x_late":"<p>rootとしてログインし、rpmをご使用のハードディスク上のディレクトリにダウンロードし、そのディレクトリに移動します。<br />\n<br />\n<strong>注記</strong>：RoCEのユーザースペース機能を有効にするために、使用されているカーネルバージョンやタイプにかかわらず、\"mlnx-ofa_kernel-4.9\" RPMをインストールする必要があります。RoCEのユーザースペースライブラリであるRPM（mlnx-ofa_kernel）はOS配布に含まれるOpenMPI RPMと競合することがあります。これは既知の挙動です。Linux分布からのOpenMPI RPMは\"mlnx-ofa_kernel\"のインストレーションの前にはターゲットのノードにインストールされないことに注意が必要です。もし既にインストールされていれば、 HPE Mellanox RoCEのドライバーパッケージをインストールする前にすべてのOpenMPI配布のRPMをアンインストールしてください。<br />\n<br />\nドライバーをインストールまたはアップグレードするには次のようにします。<br />\n4.12.14-94.41-defaultカーネルまたは任意の将来のerrataを使用する場合：<br />\n<br />\n<strong># rpm -Uvh mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_94.41-OFED.4.9.3.1.6.1.sles12sp4.x86_64.rpm</strong><br />\n<br />\nセットアップは完了しました。ドライバーを有効にするにはコンピューターを再起動します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP4 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3082.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of Intel NIC firmware running under Microsoft Windows Server 2016, Microsoft Windows Server 2019 and Windows Server 2022"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7032760","datemodified":"2021-12-20T09:38:09","file_list":["cp050583.xml","cpqsetup.exe","FW/","FW/BootIMG_ISA.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP_ISA.txt","FW/HPE_i350T4_K68277_80001099.txt","FW/HPE_i350T4_OCP_K53978_80001097.txt","FW/HPE_I350_2p_Cu_NCSI_1.61_8000108E.txt","FW/HPE_I350_4p_Cu_NCSI_1.61_8000108F.txt","FW/HPE_X710DA2_8p50_CFGID7p2_K97470_8000B735.bin","FW/HPE_X710DA2_OCP3_8p50_CFGID7p2_K97342_8000B734.bin","FW/HPE_X710_DA_OCP3_EEPROM_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"46141a78cda8943dee05f34996dcf6f9","name":"cp050583.exe","release":"2021-12-20T09:30:28","revision":"0","sha1sum":"6a750b4454e89d53557b8692d50e1bbd18185346","size":"6MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"0b5ea35199d249309413cdf1ab404c23","version":"663f66768b0e48c0b51b4488959a9793"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-20T08:32:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the&nbsp;incorrect translation is seen with Intel Intel I350-T4 Ethernet 1Gb 4-port BASE-T&nbsp;&nbsp;Adapter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This product is now supported Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Emulex 10/20 GbE Server Adapters running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品には、VMware vSphere 6.5で動作するHPE Emulex 10/20GbEサーバーアダプター用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1216.4.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン12.0.1216.4が含まれています。</p>\n"}],"files":[{"bytes":"359625","datemodified":"2020-06-11T04:20:11","file_list":["/cp044545.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/elxnet-12.0.1216.4-1OEM.650.0.0.4598673.x86_64.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/README.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/doc/release_note_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.txt","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/vib20/elxnet/EMU_bootbank_elxnet_12.0.1216.4-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-elxnet-12.0.1216.4.xml","/VMW-ESX-6.5.0-elxnet-12.0.1216.4-13057626.zip/VMW-ESX-6.5.0-elxnet-12.0.1216.4-offline_bundle-13057626.zip/metadata.zip/vibs/elxnet--643300737.xml"],"md5sum":"73a836ddc98f3eb98525843514c008a6","name":"cp044545.zip","release":"2020-06-11T04:19:09","revision":"0","sha1sum":"bf360b6dd6202191a5a4acf53d1b0e689415ee3f","size":"351KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbc5a6557"],"type_of_change":"0","version":"2020.09.14","vib_list":[{"name":"elxnet","version":"12.0.1216.4-1OEM.650.0.0.4598673"}]}],"id":{"product":"8c5c6a0f19974bc4868c84a832f1b780","version":"d1989fededf14742a3977e71fe62ea9e"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue vmnic flapping caused the network connectivity to be affected.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"elxnet:12.0.1216.4-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM1_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM1_V1.46.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1816036156","Version":"1.46"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM1 storage backplanes."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14021899","datemodified":"2022-01-12T17:47:01","file_list":["/CP050721_BUILD_8.data","/CP050721.vmexe","/CP050721.vmexe64","/CP050721.vmfile","/CP050721_VMw.zip","/CP050721.xml","/payload.json","/CP050721_VMw.zip/index.xml","/CP050721_VMw.zip/vendor-index.xml","/CP050721_VMw.zip/metadata.zip","/CP050721_VMw.zip/vib20/CP050721/HPE_bootbank_CP050721_1.46.8-7.0.0.15843807.vib","/CP050721_VMw.zip/metadata.zip/vendor-index.xml","/CP050721_VMw.zip/metadata.zip/vmware.xml","/CP050721_VMw.zip/metadata.zip/vibs/CP050721--2546678867842244770.xml","/CP050721_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050721_1.46.8-7.0.0.15843807.xml"],"md5sum":"77c18d3eb4463d33e9691bd90a8b5bb8","name":"CP050721.zip","release":"2022-01-12T17:24:26","revision":"0","sha1sum":"b2d36f2c32a4e728be259ed39dfc0553b7b9c7be","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1816036156"],"type_of_change":"1","version":"1.46","vib_list":[{"name":"CP050721","version":"1.46.8-7.0.0.15843807"}]}],"id":{"product":"2cb6e0e14bb34d32a787920ab2722d11","version":"c0a21fbd87ed4290933180df34d4dd06"},"installation":{"command":"CP050721.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM1 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor VMware Esxi - Gen10Plus UBM1バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901501000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-06T06:39:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Correct device GUID</p>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM1","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含 Emulex 光纖通道主機匯流排配接卡的 Windows 64 位元作業系統上提供對 Smart SAN 的支援套件。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Windows 64 bit operating systems."},{"lang":"ko","x_late":"이 패키지에는 Windows 64 비트 운영 체제에서 Emulex 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Windows 64 位操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、Windows 64ビット オペレーティングシステムでEmulex ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1579664","datemodified":"2021-08-25T10:15:33","file_list":["cp047610.xml","cpqsetup.exe","cp_data.xml","ElxSmartSANInstaller.dll","ELXSMARTSANVer.exe","esmartsan_cfg_cn.xml","esmartsan_cfg_en.xml","esmartsan_cfg_ja.xml","get_ss_status.bat","SmartSAN_Readme.txt","smartsan_x64.exe","ss_disable.bat","ss_enable.bat"],"md5sum":"215836034d0c0c4a5b82aad527a2beeb","name":"cp047610.exe","release":"2021-08-25T10:12:06","revision":"0","sha1sum":"64bfae6b1403e384b58243ce97733e1d647f2d80","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb135dd88"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"cdb3eb30e49445858807ae13ca01829a","version":"3ff84015279647b29005b5634a15bc36"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Microsoft Windows Server 2016/2019 (x86_64) "}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-19T10:47:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"ELXSMARTSANVer.exe","sw_key_expectedpath":"%systemdrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"20_32_1010-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.32.1010"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"Mellanox HPE signed PLDM Firmware Package for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653106A-HDAT PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 MCX653106A-HDAT PCIe4 x16アダプター用Mellanox HPE署名済みPLDMファームウェアパッケージ"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter(P31324-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>MT_0000000594</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"5952513","datemodified":"2021-12-07T10:02:16","file_list":["20_32_1010-MCX653106A-HDA_HPE_Ax.pldm.signed","20_32_1010-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"md5sum":"240eb2650e3703c77d3085dbda0eae4c","name":"20_32_1010-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","release":"2021-12-07T09:59:17","revision":"0","sha1sum":"83339cb08258f77f0c59b7c6c0052dbee5c9f081","size":"5MB","target_guids":["a6b1a447-382a-5a4f-15b3-101b15900345"],"type_of_change":"1","version":"20.32.1010"}],"id":{"product":"ab42380273374a988dbcb1a25432ed96","version":"ca60e96dfddb47d599800ec385924fb6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Flash the PLDM firmware using any below methods</p>\n\n<ol>\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p>1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px\">Reboot your system for the update to take effect immediately</p>\n\n<p>3.&nbsp;Flash from iLO GUI</p>\n\n<ul>\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol>\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p>1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p>2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li style=\"margin-left: 80px;\">\n\t<p>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li style=\"margin-left: 80px;\">\n\t<p>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p>3. iLO GUIからのフラッシュ</p>\n\n<ul>\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox Firmware Package(FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 MCX653106A-HDAT PCIe4 x16 Adapter"},{"lang":"ja","x_late":"HPE InfiniBand HDR/Ethernet 200Gb 2ポートQSFP56 MCX653106A-HDAT PCIe4 x16アダプター用Mellanoxファームウェアパッケージ（FWPKG）"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T06:51:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Additional Fixes included in version 20.31.1014:</li>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.&nbsp;</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n\t<li>Improved PortXmitWait IB counter accuracy.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Blade Storage Mezzanine Fibre Channel over Ethernet Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3324746","datemodified":"2021-09-07T05:04:05","file_list":["./etc/depmod.d/brcmfcoe.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe","./lib/modules/3.10.0-1127.el7.x86_64/extra/brcmfcoe/brcmfcoe.ko","./usr/share/smartupdate/kmod-brcmfcoe/component.xml"],"md5sum":"87918a62250695c9f303908465708f0a","name":"kmod-brcmfcoe-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-09-07T04:56:08","revision":"0","sha1sum":"d4234e343d7f38b8de54d1a2c7461c4827564194","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec19159e5c"],"type_of_change":"1","version":"12.0.1342.0"}],"id":{"product":"4ff3517aac1346d786660aa0bedadd20","version":"cd7f8703e95d4e44ae35a25a10a20aeb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh brcmfcoe-kmp-default-11.2.xxxx.x_3.0.76._0.11-1.rhel7u8.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e brcmfcoe-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel over Ethernet (FCoE) Driver Kit for HPE Storage Emulex(BRCM) Converged Network Adapters and mezzanine Converged Network Adapters(CNAs)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:12:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where cluster nodes could be evicted during Fibre Channel over Ethernet (FCoE) multipath failover as described in <a href=\"https://access.redhat.com/solutions/3136041\">https://access.redhat.com/solutions/3136041</a></li>\n\t<li>Fixed a behavior where Ethernet connections may not recover after a Virtual Connect (VC) interconnect module reboot</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.0.1342.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"kmod-brcmfcoe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U50_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34210704","datemodified":"2022-02-07T08:11:21","file_list":["cp050647.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U50_1.58_01_13_2022.signed.flash"],"md5sum":"8f458159dcacddf97b876a71a84f8a74","name":"cp050647.exe","release":"2022-02-07T08:09:15","revision":"0","sha1sum":"f7459854e9b3ea946e1ef102738efba76d367896","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022b"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"c3e42591dc7346b48d6b9ae18a9810a3","version":"0898148f566d41d8ad0c8cdc3faaabff"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.     コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.      アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus（U50）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-03T02:47:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"U50","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"12998773","datemodified":"2021-08-25T06:26:28","file_list":["/CP046764_BUILD_5.data","/CP046764.vmexe","/CP046764.vmexe64","/CP046764.vmfile","/CP046764_VMw.zip","/CP046764.xml","/payload.json","/CP046764_VMw.zip/index.xml","/CP046764_VMw.zip/vendor-index.xml","/CP046764_VMw.zip/metadata.zip","/CP046764_VMw.zip/vib20/CP046764/HPE_bootbank_CP046764_2021.10.01.5-6.5.0.4240417.vib","/CP046764_VMw.zip/metadata.zip/vendor-index.xml","/CP046764_VMw.zip/metadata.zip/vmware.xml","/CP046764_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046764_2021.10.01.5-6.5.0.4240417.xml","/CP046764_VMw.zip/metadata.zip/vibs/CP046764--2018126435713721456.xml"],"md5sum":"53140dbdceaef4f9f231f7aaca074301","name":"CP046764.zip","release":"2021-08-25T06:19:12","revision":"0","sha1sum":"5b032d9dd3efcf4aa1c36e0200f10baf864d0b9e","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046764","version":"2021.10.01.5-6.5.0.4240417"}]}],"id":{"product":"192b893f37784f3bb19222ae8b1fcb3a","version":"98827b819a3c47b585cd82b06892484a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for VMware vSphere  6.5"},{"lang":"ja","x_late":"HPEファームウェアフラッシュfor VMware vSphere 6.5用Emulexコンバージドネットワークアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Fixed a behavior with internal engineering data display</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware version:</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:623px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Universal Boot Image</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot BIOS</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E Dual Port Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E-T Dual Port Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MM1000JEFRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314d-3030-304a45465242","Version":"HPD9"},{"DeviceName":"MM2000JEFRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SAVNGSD9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-324d-3030-304a45465243","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MM1000JEFRB and MM2000JEFRC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MM1000JEFRBおよびMM2000JEFRC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MM1000JEFRB and MM2000JEFRC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD7</p>\n\n<p><br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3590048","datemodified":"2021-07-25T17:24:58","file_list":["cp048625.xml","cpqsetup.exe","payload.json","SAVNGSD9.rel","setup.dll"],"md5sum":"e737f595ea9b4e6e2d6798ce047e728d","name":"cp048625.exe","release":"2021-07-25T17:17:05","revision":"0","sha1sum":"d87507b044faf5880b6bbe7e6adf59e85cb7b95b","size":"3MB","target_guids":["002340a5-4d00-314d-3030-304a45465242","002340a5-4d00-324d-3030-304a45465243"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"182450d5bced417a85db3271254808a7","version":"3e6deed46b464f8fb7a11b8f469da1f3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MM1000JEFRB and MM2000JEFRC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MM1000JEFRBおよびMM2000JEFRCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MM1000JEFRB","target_guid":"002340a5-4d00-314d-3030-304a45465242","type":"sas"},{"id":"MM2000JEFRC","target_guid":"002340a5-4d00-324d-3030-304a45465243","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:25:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MM2000JEFRC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MM1000JEFRB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0118"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"14073846","datemodified":"2021-12-08T15:31:19","file_list":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/CP050052.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0118-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050052.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050052.scexe"],"md5sum":"22ec70b326432d69a0bee771856e1b3f","name":"firmware-d8000-0118-1.1.x86_64.rpm","release":"2021-12-08T15:18:10","revision":"0","sha1sum":"04139dcbc608cfba83d57588dad01ebdbbd38eaf","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0118"}],"id":{"product":"a2d50341a55d404a82473ce007636a93","version":"93a70808c4364df697776c2764d30394"},"installation":{"command":"setup","command_params":"-t D8000 -v 0118 -i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff -i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff -l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Linux Smart Component Installation Instructions:</strong></p>\n\n<p><strong>Updating firmware with rpm installation:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;. </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The&nbsp;CP0xxxxx.scexe script is located in the &#39;hp-scexe-compat&#39; folder. The actual name of the &#39;firmware-d8000-&lt;version&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # ./CP0xxxxx.scexe in the &#39;/usr/lib/x86_64-linux-gnu/hp-scexe-compat&#39; location (OR)</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; #&nbsp;<em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-d8000-&lt;version&gt;-*&#39; location</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>NOTES:</strong></p>\n\n<p style=\"text-align:justify\">OPTIONS for in band enclosure flash</p>\n\n<table border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:650px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>-d, --discover &lt;absolute path to file&gt;</td>\n\t\t\t<td>Dumps discovery information in XML format to &lt;file&gt;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-e, --reflash</td>\n\t\t\t<td>Flash even if the device is already up to date</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-f, &nbsp;--force</td>\n\t\t\t<td>Always flash applicable devices (same as -e -g)</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-g, --downgrade</td>\n\t\t\t<td>Flash if the device has a later firmware</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>-s, --silent</td>\n\t\t\t<td>Do not display any text and no user interaction required</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong> &nbsp;<br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Place the SPP on a USB key using the <a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\" style=\"color: blue; text-decoration: none;\"><u>USB Key Creator Utility</u></a>.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root (You must be root in order to apply the ROM update).</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages.</li>\n\t<li>Run the launch_sum.sh in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a><a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p1194926978/v157943/P07232-003.html\"><u>&nbsp;</u></a>for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)"},{"lang":"ja","x_late":"HPE D800012 Gb SASディスクエンクロージャーROMフラッシュコンポーネント for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-23T11:37:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"<p><strong>The following enhancement has been added&nbsp;in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support of Rhel 7.8&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of Rhel 8.2&nbsp;</p>\n\t</li>\n\t<li>\n\t<p>Added support of SLES15 SP2</p>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;.</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail.</p>\n\t</li>\n\t<li>\n\t<p>Fixes a problem where after upgrade, drives in slots 1 &ndash; 96 may not appear.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U60_1.54_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v1.54 (01/13/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - 系统 ROM"},{"lang":"tw","x_late":"BIOS ─ 系統 ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - 시스템 ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - システムROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17424360","datemodified":"2022-01-17T06:56:04","file_list":["cp050006.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U60_1.54_01_13_2022.signed.flash"],"md5sum":"99001be4012105a1873653828755039b","name":"cp050006.exe","release":"2022-01-17T06:53:20","revision":"0","sha1sum":"8d49dbc15e7de8e0c26d5d8c3d02b42b10c23973","size":"16MB","target_guids":["00000000-0000-0000-0000-00000000023e"],"type_of_change":"1","version":"1.54_01-13-2022"}],"id":{"product":"8bfd6c84c6a049339ae439f038925df1","version":"e8758297dae8406da82da9e9621932fb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL20 Gen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-18T03:40:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2022. Windows Server 2022 adds a new security feature called Secured-core. Secured-core is only supported on Intel® Xeon® Processors. Secured-core servers use a combination of hardware features, firmware enablement and Windows Server operating system capabilities to provide protection against malware and rootkit security exploits. </p><p>Added a new BIOS/Platform Configuration (RBSU) option for Microsoft Secured-core Support.  Enabling this setting makes the following policy changes and configures the corresponding options: Intel® Virtualization Technology enabled, Intel® VT-d enabled, Intel® TXT Support enabled, Secure Boot enabled, TPM enabled in 2.0 mode. Disabling any of these features while Secured-core is enabled can prevent Secured-core from working properly.</p><p>Added in support for legacy UEFI boot.</p><p>Added support for Intel Pentium CPUs.</p>","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the power-on password and the administrator passwords were both cleared when clearing one or the other.  With this fix the two passwords will be treated independently as intended.</p><p>Removed Dynamic Power Capping Functionality option from the RBSU menu as this option is not supported on this platform.</p><p>Removed TPM1.2 option from the RBSU menu as this option is not supported on this platform.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"U60","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."},{"lang":"ja","x_late":"Agentless Management Service（AMSD）は、Integrated Lights Out 5（iLO 5）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2773861","datemodified":"2021-12-06T05:23:19","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqiScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"c706b63292a66932fbcb5a4d84e50d17","name":"amsd-2.6.0-1701.1.sles12.x86_64.rpm","release":"2021-12-06T05:11:27","revision":"0","sha1sum":"6e3544a1a12165805f3af46a4d2c18bbebd64909","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"2.6.0"}],"id":{"product":"5e1877c3b3394cf696fd1e1223a16f2b","version":"fd5f452716f345fcb6e94db555a4134b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<ul>\n\t<li>パッケージをインストールするには、次のようにタイプします。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-<version>.rpm</li>\n\t</ul>\n\t</li>\n\t<li>パッケージが正しくロードされているか、以下をタイプして確認します。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>以下のコマンドを実行してヘルプを参照してください。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T14:28:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>New support added to amsd:</p>\n\n<ul>\n\t<li>Enhance the direct-attached SATA Drive Status - smart Error&nbsp;and failed.</li>\n\t<li>Enhance the direct-attached SATA Drive Status under hot-plug and hot-remove.</li>\n\t<li>Provide the new OID, cpqIdeAtaDiskCapacityLowBytes and cpqIdeAtaDiskCapacityHighBytes for SATA HD capacity support:</li>\n\t<li>HPE Synergy 4610C 10/25Gb Ethernet Adapter.</li>\n\t<li>HPE FC HBA/SN1700E</li>\n\t<li>HPE DSP DSC-25/100 Ent/Cld 10/25/100Gb</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under Red Hat Enterprise Linux 7."},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"954366","datemodified":"2021-03-08T18:00:27","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1160.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"9fbe61d65c431f81c9be90ea4411938f","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u9.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"0546c14ec984fd6a5be1158c3920cdcfbee5b2f6","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"953499","datemodified":"2021-03-08T17:57:49","file_list":["./etc/depmod.d/be2iscsi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi","./lib/modules/3.10.0-1127.el7.x86_64/extra/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/kmod-be2iscsi_bl/component.xml"],"md5sum":"6d7f1c3af7361bf93c309b2a77956caf","name":"kmod-be2iscsi_bl-12.0.1342.0-1.rhel7u8.x86_64.rpm","release":"2021-03-08T17:52:05","revision":"0","sha1sum":"963ca324b280912edc8713043fc0ccff922fb5e0","size":"931KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb2fe523e"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"72bb108f558244ddb21ec2debe092df6","version":"7731e7e28e18499896b56c654e829017"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Drivers for Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbE iSCSIドライバー for Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 7, Updates 8 and 9.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"},{"name":"kmod-be2iscsi_bl","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"},{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Added support for RHEL 8.4 and SLES15SP3.</p>\n\t</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5148570","datemodified":"2021-07-23T08:01:06","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/CP048096.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/SNEMOTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0b575b5895-HPG3-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048096.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048096.scexe"],"md5sum":"d55e2b4fd4a5a502fbd728620aec9864","name":"firmware-hdd-0b575b5895-HPG3-8.1.x86_64.rpm","release":"2021-07-23T07:48:08","revision":"0","sha1sum":"f4eecdd56b3d5d4fee8463ddbd9bd2390dcd7794","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304757464748","4d2340a5-3042-3130-3030-304757464746"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"81e371ec59e54de18ebca5fd69821033","version":"927a5a6d7d1f4ece98ee102e09ad55af"},"installation":{"command":"CP040332.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:26:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 7.0."},{"lang":"ja","x_late":"このパッケージには、ESXi 7.0上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"16854420","datemodified":"2022-02-05T17:21:28","file_list":["/CP050393.vmexe64","/CP050393.vmfile","/CP050393.xml","/CP050393_VMw.zip","/payload.json","/README.txt","/CP050393_VMw.zip/index.xml","/CP050393_VMw.zip/vendor-index.xml","/CP050393_VMw.zip/metadata.zip","/CP050393_VMw.zip/vib20/CP050393/HPE_bootbank_CP050393_1.0.4-7.0.0.15525992.vib","/CP050393_VMw.zip/metadata.zip/vendor-index.xml","/CP050393_VMw.zip/metadata.zip/vmware.xml","/CP050393_VMw.zip/metadata.zip/vibs/CP050393-2269135244957030846.xml","/CP050393_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050393_1.0.4-7.0.0.15525992.xml"],"md5sum":"6f7df10e759d955b24714e21d92b4b1a","name":"CP050393.zip","release":"2022-02-05T17:23:05","revision":"0","sha1sum":"639e08b3387cb6daf715a7dfce6a347ef98b081e","size":"16MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050393","version":"1.0.4-7.0.0.15525992"}]}],"id":{"product":"d9e21a24798447d3b9521f317ae3815c","version":"00e3f5944f7f47fca9b8d9cbd78ad306"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 7.0）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T08:52:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.31.1014:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel i40eb 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1460992","datemodified":"2022-01-25T15:20:51","file_list":["cp049617.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"a58e7e8bfbb864034760064625d9c48a","name":"cp049617.exe","release":"2022-01-25T15:07:03","revision":"0","sha1sum":"cfd3f8be1cadf04aa554b6bfbe681a68315bf5bb","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"type_of_change":"1","version":"1.16.141.0"}],"id":{"product":"1188e33080924486b998a030d43acf6f","version":"af883b1a9ff94130b9b9672ca5305a42"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40eb Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-22T06:28:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial&nbsp;version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"i40eb.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLPeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB008000GWRTC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB008000GWRTC Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4162280","datemodified":"2021-07-23T12:50:34","file_list":["cp048669.xml","cpqsetup.exe","HVLPeAaseFG1.rel","payload.json","setup.dll"],"md5sum":"8e80fd97ab5c8248faddc31980e90f87","name":"cp048669.exe","release":"2021-07-23T12:43:06","revision":"0","sha1sum":"5669200d4be0e781850b7e8dcee4c397dda105d2","size":"3MB","target_guids":["4d2340a5-3042-3830-3030-304757525443"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"92d9bf17d9ef471e842a80e42a41ec72","version":"0e752a2b01ad46b3a7ceae87ec4bfd22"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB008000GWRTCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWRTC","target_guid":"4d2340a5-3042-3830-3030-304757525443","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:16:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000GWRTC","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd189c612bf3","Version":"1.79"},{"DeviceName":"HPE Apollo 4200 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Tiburon-Release-1.79-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18699cb91d","Version":"1.79"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen9 and Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen9およびGen10のバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 4200 Gen9 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.79<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.78(A)<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名:<br />\n     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4200 Gen9バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.79<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     1.79<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     1.78(A)<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n     なし        <br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<p>     なし\n        </p>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p>     システムの再起動後にドライブが表示されない場合があります。</p>\n\n<p><strong>既知の問題点:</strong><br />\n     なし        </p>\n"}],"files":[{"bytes":"10225395","datemodified":"2020-03-16T19:54:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/CP043500.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/Tiburon-Release-1.79-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/libsetup2.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/setup2","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/storcli-1.25.12-1.noarch.rpm","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-1.79-1.1/supplement","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP043500.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP043500.scexe"],"md5sum":"85e2077a96cf78c5cc41c71573098e25","name":"firmware-smartarray-f18fdefd0b-1.79-1.1.x86_64.rpm","release":"2020-03-16T00:00:00","revision":"1","sha1sum":"4110da65aaa884f6ec4c39ef83847ac17f2fbb42","size":"9MB","target_guids":["b99dfb74-f0bc-464f-b418-cd189c612bf3","b99dfb74-f0bc-464f-b418-cd18699cb91d"],"type_of_change":"1","version":"1.79"}],"id":{"product":"63b5acd6b69146b7aacdd66e3c7732d6","version":"8457a24a91934fc1a93f9182d238fbda"},"installation":{"command":"CP038809.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><u>Power cycle / cold reboot is required if firmware is upgraded from version 1.03 or earlier.</u></p>\n\n<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP038809.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f18fdefd0b-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./ CP038809.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f18fdefd0b-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><u>ファームウェアがバージョン1.03またはそれ以前からアップグレードされた場合には、電源再投入/コールドリブートが必要です。</u></p>\n\n<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP038809.scexeスクリプトは 'scexe-compat'フォルダーにあります。'firmware-smartarray-f18fdefd0b-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます:\n\t<ul>\n\t\t<li>./ CP038809.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li><em>./setup</em> ('/usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*' にあります)</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li> 'usr/lib/x86_64-linux-gnu/firmware-smartarray-f18fdefd0b-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f18fdefd0b-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong></p>\n\n<p><strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン:</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 4200バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"3239","subdev":"21c1","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c1","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c2","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c3","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c3","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c5","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c5","type":"pci","ven":"103c"},{"dev":"3239","subdev":"21c8","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3239103c21c8","type":"pci","ven":"103c"},{"id":"Apollo 4200 LFF","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-05-02T14:37:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Drive may show up&nbsp;missing after a system reboot.</p>\n\n<p>Please reference Customer Advisory a00098241en_us</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"}],"sw_keys":[{"name":"Apollo 4200 SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 4200 LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"firmware-Signed-5.10-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.10"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure firmware on HPE ProLiant Gen9 expanders"},{"lang":"cn","x_late":"升级HPE ProLiant Gen9扩展卡上机柜固件的在线智能组件"},{"lang":"tw","x_late":"可升級 HPE ProLiant Gen9 擴充卡上機櫃韌體的線上智慧型元件"},{"lang":"ko","x_late":"HPE Proliant Gen9 Expander에서 인클로저 펌웨어를 업그레이드하는 온라인 스마트 구성 요소"},{"lang":"ja","x_late":"HPE ProLiant Gen9エキスパンダーのエンクロージャーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"30313071","datemodified":"2021-08-16T14:45:54","file_list":["/CP049281_BUILD_2.data","/CP049281.vmexe","/CP049281.vmexe64","/CP049281.vmfile","/CP049281_VMw.zip","/CP049281.xml","/payload.json","/CP049281_VMw.zip/index.xml","/CP049281_VMw.zip/vendor-index.xml","/CP049281_VMw.zip/metadata.zip","/CP049281_VMw.zip/vib20/CP049281/HPE_bootbank_CP049281_5.10.2-7.0.0.15843807.vib","/CP049281_VMw.zip/metadata.zip/vendor-index.xml","/CP049281_VMw.zip/metadata.zip/vmware.xml","/CP049281_VMw.zip/metadata.zip/vibs/CP049281--5876029568697298306.xml","/CP049281_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049281_5.10.2-7.0.0.15843807.xml"],"md5sum":"3193b1195ed0d476cf042657b0bcf3f5","name":"CP049281.zip","release":"2021-09-06T00:00:00","revision":"2","sha1sum":"8c326b6f82f0a943539d0a3e7c5fc9d24d03f3cc","size":"28MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"type_of_change":"1","version":"5.10","vib_list":[{"name":"CP049281","version":"5.10.2-7.0.0.15843807"}]}],"id":{"product":"1655bc494b334729864d929c38544849","version":"47cdce239c04473f9ee4895a34bd75e8"},"installation":{"command":"CP049281.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp; &nbsp; &nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n\t<li>Reboot your system, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />\n<br />\n      リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n<br />\n<strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>コマンドを使用してCPXXXXXX.vmexeが実行可能であることを確認します：</li>\n</ul>\n\n<p>             chmod +x CPXXXXXX.vmexe    </p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>ファームウェアアップデートを有効にするためにシステムを再起動します。</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor VMware ESXi - HPE 12 Gb/s SASエキスパンダーファームウェアfor HPE SmartアレイコントローラーおよびHPE HBAコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-11T08:54:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>To make Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Valid flag is always set to true initially so that CRC check can be performed on initstring partition and test if it is really valid.</li>\n\t<li>Move Smart Carrier Authentication to later in the boot process and move the Exception Dumper task to earlier in the process in order to support Winbond alternative Flash</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"12G SAS Exp Card","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A41_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションからリモートサーバーのファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"17574016","datemodified":"2022-02-21T05:14:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/A41_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/CP050799.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050799.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050799.scexe"],"md5sum":"a642f28e30f77b4082dcc92cfda20b67","name":"firmware-system-a41-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T05:08:05","revision":"0","sha1sum":"e26c03dec618bcb96722481cb0f00999e52a17fd","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000217"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"d152e4f9638d4a6a962a3424ad625ef5","version":"a031b8f2691e4723a6864497d1aa2e57"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL325 Gen10 (A41)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-18T06:07:07","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"}],"sw_keys":[{"name":"A41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800214","languages":[{"lang":"fr","x_late":"Logiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Software - Storage Controller"},{"lang":"cn","x_late":"软件 - 存储控制器"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Software - Speichercontroller"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Software - Controller di memorizzazione"},{"lang":"ja","x_late":"ソフトウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Software - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"StorCLI is a command line interface that enables multiple users to perform maintaining, troubleshooting, and configuration functions for the MegaRAID® products. It also helps you to create and manage storage configurations. StorCLI can display the status of the controller cards, virtual drives, and drives on the controller. You can use the CLI to perform system maintenance tasks, such as updating the controller firmware. This tool enables you to monitor the controllers and configure the virtual drives and drives on the controller. You can easily create new storage configurations and modify the configurations."},{"lang":"ja","x_late":"コマンドラインインターフェイスのStorCLIを使用すると、複数のユーザーがMegaRAID®製品の保守、トラブルシューティング、および構成の各機能を実行できます。また、これはストレージ構成の作成と管理にも役立ちます。StorCLIでは、コントローラー上のコントローラーカード、仮想ドライブ、およびドライブのステータスを表示できます。このCLIを使用して、コントローラーファームウェアのアップデートなど、システムメンテナンスタスクを実行できます。このツールを使用すると、コントローラーを監視したり、コントローラー上の仮想ドライブおよびドライブを構成したりできます。新しいストレージ構成の作成および構成の変更を容易に行うことができます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"cn","x_late":"存储设备"},{"lang":"ja","x_late":"ストレージ"}]}],"documentation":[],"files":[{"bytes":"2066542","datemodified":"2020-09-04T07:03:53","file_list":["/cp045835.xml","/storcli-esxi6.5-bundle-1.25.16.zip","/storcli-esxi6.5-bundle-1.25.16.zip/index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip","/storcli-esxi6.5-bundle-1.25.16.zip/vmware-esx-storcli-1.25.16.vib","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vendor-index.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vmware.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/vibs/vmware-esx-storcli-1.25.16--1295600419012277576.xml","/storcli-esxi6.5-bundle-1.25.16.zip/metadata-storcli-esxi6.5-bundle-1.25.16.zip/bulletins/HPE-esx-6.5.0-storcli-1.25.16.xml"],"md5sum":"285137ef96fcad68c8e4f1ecf23a90c3","name":"cp045835.zip","release":"2020-09-04T07:03:09","revision":"0","sha1sum":"67c1712ad04f915ef245134655e5cf145b7676da","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf774e4ad"],"type_of_change":"0","version":"2021.04.00","vib_list":[{"name":"vmware-esx-storcli-1.25.16","version":"1.25.16-01"}]}],"id":{"product":"836a010b07664062aae0167a44b26380","version":"f7b8b9e21ea54850ad5ec819ec12f24c"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.7/6.5/6.0 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v=&lt;path&gt;&lt;filename.vib&gt; --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIB Package can be removed using the command</li>\n</ul>\n\n<p><strong>~# esxcli software vib remove -n<strong>=&lt;</strong>filename.vib&gt;</strong></p>\n"},{"lang":"ja","x_late":"<p><strong>ESXiシェルからのESXi 6.7/6.5/6.0ホストへのVIBのインストール：</strong></p>\n\n<ul>\n\t<li>ESXiホストのローカルパスへのVIBの転送</li>\n\t<li>ESXiシェルで以下のesxcliコマンドを実行して、VIBをインストールします。</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v=<path><filename.vib> --no-sig-check</strong></p>\n\n<ul>\n\t<li>VIBパッケージは次のコマンドを使用して削除できます</li>\n</ul>\n\n<p><strong>~# esxcli software vib remove -n<strong>=<</strong>filename.vib></strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MegaRAID Storage Administrator StorCLI for VMware6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2020-10-04T06:51:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated Product&nbsp;Name with the OS version.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Initial build</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"vmware-esx-storcli-1.25.16:1.25.16","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE QLogicメザニンファイバーチャネルドライバーfor VMware vSphere 6.7"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"814401","datemodified":"2021-08-27T04:16:24","file_list":["/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip","/cp046774.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/README.txt","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/doc/release_note_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.qlnativefc","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/vib20/qlnativefc/Marvell_bootbank_qlnativefc_3.1.46.0-1OEM.670.0.0.8169922.vib","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/vibs/qlnativefc-3264416984770026613.xml","/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-17199116.zip/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922-offline_bundle-17199116.zip/metadata.zip/bulletins/MRVL-QLogic-FC_3.1.46.0-1OEM.670.0.0.8169922.xml"],"md5sum":"da7b3d9df2f5ce11a50c0c74e2926819","name":"cp046774.zip","release":"2021-09-23T00:00:00","revision":"1","sha1sum":"9c4d805cf344dedb15d3f917c07627e59fc6b27b","size":"795KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"qlnativefc","version":"3.1.46.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"f509039a672245dc846e395d9ac11727","version":"d0bbee5b787d485f8973af644d582d58"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware&nbsp;vSphere Update Manager&nbsp;or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VMware&nbsp;vSphere Update Manager and the esxcli commands</li>\n</ul>\n"},{"lang":"ja","x_late":"<p> <strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:</strong><br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware vSphere Update Managerまたはesxcliコマンドを使用します。</li>\n\t<li>VMware vSphere Update Managerおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Mezzanine Fibre Channel driver component for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE QLogicメザニンファイバーチャネルドライバーコンポーネントfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-26T05:51:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed an unwanted behavior where Get Port Speed Capabilities (GPSC) failures were leading to intelligent interleaved direct memory access (IIDMA) for target being set to 1GB/s. This is described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00115969en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running VMware ESXi 6.5 / 6/7 / 7.0 and Configured With Certain HPE Host Bus Adapters May Experience Severe Performance Degradation When Connected to Brocade FOS v8.0.1 (or Prior)</a></li>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Added the following:</strong></p>\n\n<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation(USCM) Congestion Management algorithm</li>\n\t<li>\n\t<p>Implemented the vmkmgmt Application programming Interface (API) to report Non-Volatile Memory Express (NVMe) target info and send Non-Volatile Memory Express (NVMe) pass through commands</p>\n\t</li>\n</ul>\n\n<p>Driver version 3.1.46.0</p>\n","curr_fixes_x_late":"<p><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Addressed unwanted behavior with Fabric Port Identification Number (FPIN) based congestion throttling leading to poor performance.</li>\n\t<li>Fixed an unwanted behavior where stale connection IDs could be used with Fibre Channel- Non Volatile Memory Express (FC-NVMe) traffic.</li>\n\t<li>\n\t<p>Fixed an unwanted behavior with response queue handling to avoid the problem referenced by <a href=\"https://kb.vmware.com/s/article/81721\">https://kb.vmware.com/s/article/81721</a></p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"qlnativefc:3.1.46.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"en","x_late":"This Smart Component contains the firmware image for the HP 6Gb SAS BL Switch.  After downloading the component and extracting the firmware image to a directory, access the Virtual SAS Manager's GUI or CLI interface to flash the firmware."},{"lang":"ja","x_late":"このSmart Componentには、HP 6Gb SAS BLスイッチのファームウェア イメージが含まれています。  コンポーネントをダウンロードしてディレクトリにファームウェア イメージを展開したら、Virtual SAS ManagerのGUIかCLIインターフェイスにアクセスしてファームウェアをフラッシュします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;4.3.6.0 (B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.2.0<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; 4.2.1.0<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; The devices listed below require minimum FW deliverables with HP Storage Manager version 4.1.1.0:<br />\n<br />\n<strong>Device, Minimum Recommended Version</strong></p>\n\n<ul>\n\t<li>HP D3600/D3700/D3610/D3710 Disk Enclosure, 3.64</li>\n\t<li>HP D2600/D2700 Disk Enclosure, 0150</li>\n\t<li>HP 600 Modular Disk System, 3.68</li>\n\t<li>HP D6000 Disk Enclosure, 2.98</li>\n\t<li>HP D6020 Disk Enclosure, 2.53</li>\n</ul>\n\n<p><strong>Enhancements/New Features for FW version 4.3.6.0 (B):</strong><strong>&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:40px\">None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; None<br />\n&nbsp;</p>\n"}],"files":[{"bytes":"34000365","datemodified":"2018-09-26T20:07:41","file_list":["./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.cpq_package.inc","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/.setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/CP037681.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/cp_data.xml","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/hpsetup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/setup","./usr/lib/i586-linux-gnu/firmware-solex6gb-solex-4.3.6.0-2.1/vsm_release_4.3.6.0.img","./usr/lib/i586-linux-gnu/hp-scexe-compat","./usr/lib/i586-linux-gnu/hp-scexe-compat/CP037681.scexe","./usr/lib/i586-linux-gnu/scexe-compat","./usr/lib/i586-linux-gnu/scexe-compat/CP037681.scexe"],"md5sum":"301d93fa1148fd24956bbc22a2fe057c","name":"firmware-solex6gb-solex-4.3.6.0-2.1.i586.rpm","release":"2018-09-27T01:00:04","revision":"0","sha1sum":"be24adb881bd827d01e426b4302589725d1bdd4a","size":"32MB","target_guids":[],"type_of_change":"0","version":"4.3.6.0"}],"id":{"product":"a2a4da3071f14ea0b229b51686cf6bd9","version":"0ed32969accd4e30809f5ca59302841a"},"installation":{"command":"Entry.bsh","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installation Instructions:</strong></p>\n\n<p><br />\n<strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;rpm -ivh &lt;rpm_filename&gt;.&nbsp;&nbsp;This extracts the contents of the rpm to the &#39;/usr/lib/<strong>x86_64-linux-gnu</strong>&#39; location</li>\n\t<li>To uninstall the rpm, run the command: rpm -e &lt;rpm_package_name&gt;, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm</em></strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;&nbsp;</em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system.&nbsp;</p>\n\n<p>&nbsp;</p>\n\n<p><strong><strong>HP recommends for remote deployment of this package that you obtain the most recent version of the&nbsp;</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a><strong>(SPP) and follow these steps:</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>..</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO.</li>\n\t<li>Follow the GUI instructions to install the firmware on the remote host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>インストール手順：</strong></p>\n\n<p><br />\n<strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>コマンドpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします：  これは、'/usr/lib/<strong>x86_64-linux-gnu</strong>' の場所へrpm の内容を解凍します。</li>\n\t<li>rpmをアンインストールするには、次のコマンドを実行します。<rpm_package_name> これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート</em></strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n</ul>\n\n<p><strong><em>追加情報:</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。 </p>\n\n<p> </p>\n\n<p><strong><strong>このパッケージのリモートデプロイメントには、最新のバージョンの</strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a><strong>（SPP）を入手して、以下の手順を実行することをおすすめします。</strong></strong></p>\n\n<ul style=\"list-style-type: square;\">\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>GUIの指示に従ってリモートホストにファームウェアをインストールします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HP 6Gb SAS BL Switch Firmware Smart Component for Linux (x86/x64)"},{"lang":"ja","x_late":"オンラインHP 6Gb SAS BLスイッチファームウェア Smart Component for Linux (x86/x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"id":"HP6GSASBLSWH","target_guid":"","type":"sas"}],"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-10-24T18:13:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial drop for Snap3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"solex","sw_key_expectedpath":"firmware:solex6Gb"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000JVYZD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a56595a44","Version":"HPD4"},{"DeviceName":"MB4000JVYZC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPESD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a43","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models:MB6000JVYZD and MB4000JVYZC"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、ドライブモデル：MB6000JVYZDおよびMB4000JVYZCのファームウェアを提供します。"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB6000JVYZD and MB4000JVYZC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5565082","datemodified":"2021-07-23T07:47:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/CP048173.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/SMBPESD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e800e8d3b9-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048173.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048173.scexe"],"md5sum":"f392fcb737a3c664ce3a0b45a5b4a1d0","name":"firmware-hdd-e800e8d3b9-HPD4-6.1.x86_64.rpm","release":"2021-07-23T07:34:06","revision":"0","sha1sum":"f76a9a653857e49d5a6d65565940ba725e85ece0","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304a56595a44","002340a5-4d00-3442-3030-304a56595a43"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f433cea5bd0849d286e6c1b1e45a60d4","version":"830d25e99e0c450f93f02ebd5ce8a635"},"installation":{"command":"CP040325.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB6000JVYZD and MB4000JVYZC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000JVYZDおよびMB4000JVYZCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000JVYZC","target_guid":"002340a5-4d00-3442-3030-304a56595a43","type":"sas"},{"id":"MB6000JVYZD","target_guid":"002340a5-4d00-3642-3030-304a56595a44","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T20:01:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JVYZC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JVYZD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A48_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33586352","datemodified":"2022-02-21T13:02:35","file_list":["A48_2.56_02_10_2022.signed.flash","A48_2.56_02_10_2022.xml","payload.json"],"md5sum":"475e9ff136b316c5380e48da2f34f0d1","name":"A48_2.56_02_10_2022.fwpkg","release":"2022-02-21T12:58:25","revision":"0","sha1sum":"3a754f5b7cd7a992846255d6d7566e8277462616","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022f"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"c91a34b258694c1696514c7b51041b33","version":"c610d4c641cf4033b382c6ae72528da3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus(A48) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:44:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A48","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK3"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK3"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK3"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK3"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK3"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK3"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK3"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE80X0AHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following NVME drive models: VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のNVMEドライブモデルのファームウェアを提供します。VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) -&nbsp;VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPK2<br />\n<br />\n<strong><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Sever 2022.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5888008","datemodified":"2021-08-17T12:50:00","file_list":["cp049303.xml","cpqsetup.exe","KPE80X0AHPK3.rel","payload.json","setup.dll"],"md5sum":"7023f617c928074cd73db126d95b2853","name":"cp049303.exe","release":"2021-08-17T12:42:29","revision":"0","sha1sum":"9873cd9fea32d98b5cf9d6110175a29a01ce891d","size":"5MB","target_guids":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"type_of_change":"2","version":"HPK3"}],"id":{"product":"912bdc2895264227ab4d6d2895102ac1","version":"4dc299694aed4c4f9e3e9ed0f90588c8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO000960KXAVL、VO001920KXAVP、VO003840KXAVQ、VO007680KXAVR、MO000800KXAVN、MO001600KXAVT、MO003200KXAVU、MO006400KXAVVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO000960KXAVL","target_guid":"562340a5-304f-3030-3936-304b5841564c","type":"nvme"},{"id":"MO000800KXAVN","target_guid":"4d2340a5-304f-3030-3830-304b5841564e","type":"nvme"},{"id":"MO001600KXAVT","target_guid":"4d2340a5-304f-3130-3630-304b58415654","type":"nvme"},{"id":"MO003200KXAVU","target_guid":"4d2340a5-304f-3330-3230-304b58415655","type":"nvme"},{"id":"MO006400KXAVV","target_guid":"4d2340a5-304f-3630-3430-304b58415656","type":"nvme"},{"id":"VO003840KXAVQ","target_guid":"562340a5-304f-3330-3834-304b58415651","type":"nvme"},{"id":"VO007680KXAVR","target_guid":"562340a5-304f-3730-3638-304b58415652","type":"nvme"},{"id":"VO001920KXAVP","target_guid":"562340a5-304f-3130-3932-304b58415650","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T12:32:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Sever 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This Firmware release contains various drive interoperability enhancements and code fixes accumulated since the last firmware release, as well as a change to disable MCTP over PCIe VDM function per requested of HPE, and a PHY setting change for improved compatibility with Intel Ice Lake based Gen10+ DL360 platform.&nbsp;</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL: https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00115201en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO007680KXAVR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KXAVV","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KXAVT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KXAVP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO000960KXAVL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO003840KXAVQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KXAVU","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO000800KXAVN","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U38_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33602027","datemodified":"2022-03-10T22:04:17","file_list":["payload.json","U38_2.62_03_08_2022.signed.flash","U38_2.62_03_08_2022.xml"],"md5sum":"4c7632c9675a39ac9a02283d91fefe14","name":"U38_2.62_03_08_2022.fwpkg","release":"2022-03-10T22:00:20","revision":"0","sha1sum":"962e30ec78137c81aeca7d13807b0dc7614a4d7a","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000213"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"703e98acf33d484a9d2825573e86e8c0","version":"567ecf30a625452d9822f033320bba52"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:56:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"}],"sw_keys":[{"name":"U38","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800213","languages":[{"lang":"fr","x_late":"Logiciel - Lights-Out Management"},{"lang":"en","x_late":"Software - Lights-Out Management"},{"lang":"cn","x_late":"软件 - Lights-Out Management"},{"lang":"tw","x_late":"軟體 ─ Lights-Out 管理"},{"lang":"de","x_late":"Software - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"소프트웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ソフトウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Software - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration utility is a command line utility used to configure ProLiant Integrated Lights-Out processor (iLO) from within the Linux operating system without requiring a reboot of the server."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"60457","datemodified":"2020-10-15T06:43:56","file_list":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"md5sum":"3e991c52d2e72cb58e751f64774c0b32","name":"hponcfg-5.6.0-0.x86_64.rpm","release":"2020-10-15T06:39:06","revision":"0","sha1sum":"620aa256a415de5faaf1f9fa5e1f4464ccffd7b3","size":"59KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"type_of_change":"1","version":"5.6.0-0"}],"id":{"product":"db808d6aa2e24648bcc5e3f46d635b1a","version":"640d4499d8c64ee79f546d439f55961d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>If a previous version of the Hponcfg utility has been installed, it must be removed before this package can be installed. To remove the previous version of the package, type the following :</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>To install the package, type:</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>After installation, the executable for hponcfg utility can be found under the directory /sbin.</p>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをご使用のハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<p>Hponcfgユーティリティの以前のバージョンをインストールしている場合は、削除しておかないと、このパッケージをインストールできません。パッケージの以前のバージョンを削除するには、次のように入力します：</p>\n\n<ul>\n\t<li>rpm -e hponcfg</li>\n</ul>\n\n<p>パッケージをインストールするには、次のようにタイプします。</p>\n\n<ul>\n\t<li>rpm -ivh hponcfg-x.x.x.x86_64.rpm</li>\n</ul>\n\n<p>インストール後は、/sbinディレクトリにhponcfgの実行可能ファイルが見つかります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3309","type":"pci","ven":"103c"},{"dev":"3306","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3309","type":"pci","ven":"103c"},{"dev":"3302","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3309","type":"pci","ven":"103c"},{"dev":"3308","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3309","type":"pci","ven":"103c"},{"dev":"3301","subdev":"3309","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3309","type":"pci","ven":"103c"},{"dev":"3300","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3300103c330e","type":"pci","ven":"103c"},{"dev":"3301","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3301103c330e","type":"pci","ven":"103c"},{"dev":"3302","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3302103c330e","type":"pci","ven":"103c"},{"dev":"3306","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3306103c330e","type":"pci","ven":"103c"},{"dev":"3307","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3307103c330e","type":"pci","ven":"103c"},{"dev":"3308","subdev":"330e","subven":"103c","target_guid":"a6b1a447-382a-5a4f-103c-3308103c330e","type":"pci","ven":"103c"},{"id":"5219994","target_guid":"","type":"other"},{"dev":"3306","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3306103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3307103c3381","type":"pci","ven":"103C"},{"dev":"3308","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3308103c3381","type":"pci","ven":"103C"},{"dev":"3300","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3300103c3381","type":"pci","ven":"103C"},{"dev":"3301","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3301103c3381","type":"pci","ven":"103C"},{"dev":"3302","subdev":"3381","subven":"103C","target_guid":"a6b1a447-382a-5a4f-103c-3302103c3381","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"id":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","target_guid":"","type":"other"},{"dev":"3307","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"},{"dev":"3306","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"SUSE LINUX Enterprise Server 10 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"5","minor":"0","name":"Red Hat Enterprise Linux 5 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-06-27T08:36:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Updated the OpenSSL API calls to support Host&#39;s OpenSSL FIPS mode.</p>\n"},{"curr_enhancements_x_late":"<p>Updated product name to HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T).</p>\n","curr_fixes_x_late":"<p>Fixed an issue where HPONCFG was not able to detect openssl library when&nbsp;multiple 64-bit openssl installed.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"A16","value":"HP ProLiant DL585 G7 Server"},{"key":"I25","value":"HP ProLiant BL680c G7 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"P78","value":"HP ProLiant ML310e Gen8 v2 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I25","value":"HP ProLiant BL620c G7 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"P65","value":"HP ProLiant DL580 G7 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"J03","value":"HP ProLiant DL160 Gen8 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"P75","value":"HP ProLiant SL270s Gen8 SE Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy SY480 Gen10 Plus"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A31","value":"HP ProLiant SL4545 G7 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"P83","value":"HP ProLiant SL210t Gen8 Server"},{"key":"P77","value":"HP ProLiant DL560 Gen8 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"P68","value":"HP ProLiant DL360 G7 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P73","value":"HP ProLiant DL380e Gen8 Server"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"P88","value":"HP ProLiant ML10 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"A20","value":"HP ProLiant BL685c G7 Server"},{"key":"P67","value":"HP ProLiant DL380 G7 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P66","value":"HP ProLiant DL980 G7 Server"},{"key":"P94","value":"HP ProLiant XL220a Gen8 v2 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"P70","value":"HP ProLiant DL380p Gen8 Server"},{"key":"P71","value":"HP ProLiant DL360p Gen8 Server"},{"key":"J02","value":"HP ProLiant ML350e Gen8 Server"},{"key":"A28","value":"HP ProLiant DL385p Gen8 Server"},{"key":"P72","value":"HP ProLiant ML350p Gen8 Server"},{"key":"P75","value":"HP ProLiant SL270s Gen8 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"A19","value":"HP ProLiant BL465c G7 Server"},{"key":"A18","value":"HP ProLiant DL385 G7 Server"},{"key":"P73","value":"HP ProLiant DL360e Gen8 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"J06","value":"HP ProLiant MicroServer Gen8"},{"key":"A48","value":"HPE ProLiant XL215n Gen10 Plus"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"P75","value":"HP ProLiant SL250s Gen8 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I27","value":"HP ProLiant BL460c G7 Server"},{"key":"I28","value":"HP ProLiant BL490c G7 Server"},{"key":"J05","value":"HP ProLiant DL320e Gen8 Server"},{"key":"J04","value":"HP ProLiant ML310e Gen8 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"P80","value":"HP ProLiant DL320e Gen8 v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"P74","value":"HP ProLiant SL4540 Gen8 3 Node Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"P75","value":"HP ProLiant SL230s Gen8 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"P79","value":"HP ProLiant DL580 Gen8 Server"},{"key":"I29","value":"HP ProLiant BL2x220c G7 Server"}],"sw_keys":[{"name":"hponcfg","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWFGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757464746","Version":"HPG3"},{"DeviceName":"MB002000GWFGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SNEMOTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757464748","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000GWFGH and MB001000GWFGF "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MB002000GWFGH および MB001000GWFGF "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB002000GWFGH and MB001000GWFGF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/NewFeatures :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3324248","datemodified":"2021-07-23T19:21:22","file_list":["cp048559.xml","cpqsetup.exe","payload.json","setup.dll","SNEMOTG3.rel"],"md5sum":"c70888cc236100018bd7c2effda40003","name":"cp048559.exe","release":"2021-07-23T19:13:04","revision":"0","sha1sum":"85185c349d09fa528e189d57fb13f8882df1aa45","size":"3MB","target_guids":["4d2340a5-3042-3130-3030-304757464746","4d2340a5-3042-3230-3030-304757464748"],"type_of_change":"0","version":"HPG3"}],"id":{"product":"606295772f834fc984488410e9459b3e","version":"293e567f65b14f3fb8913e4b8e1f6888"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB002000GWFGH and MB001000GWFGF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB002000GWFGHおよびMB001000GWFGFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB001000GWFGF","target_guid":"4d2340a5-3042-3130-3030-304757464746","type":"sata"},{"id":"MB002000GWFGH","target_guid":"4d2340a5-3042-3230-3030-304757464748","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:02:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB001000GWFGF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFGH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYZB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595a42","Version":"HPG4"},{"DeviceName":"MB4000GVYZA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPETG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a41","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル： MB6000GVYZBおよびMB4000GVYZAドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB6000GVYZB and MB4000GVYZA Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5378582","datemodified":"2021-07-23T07:33:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/CP048170.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/SMBPETG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-0a7d4aa47f-HPG4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048170.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048170.scexe"],"md5sum":"bb1b0b1835b29a62a2813cbac53c9a70","name":"firmware-hdd-0a7d4aa47f-HPG4-6.1.x86_64.rpm","release":"2021-07-23T07:22:14","revision":"0","sha1sum":"9482763405db73bc80165119a6ab7bbe79a7f5fa","size":"5MB","target_guids":["002340a5-4d00-3642-3030-304756595a42","002340a5-4d00-3442-3030-304756595a41"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d7e21057ac6640f0b343d9d0d83a30a1","version":"968fcda0c0454b388ca6436102d94916"},"installation":{"command":"CP040339.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Follow the instructions on the screen.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">画面の指示に従います。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GVYZB and MB4000GVYZA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GVYZBおよびMB4000GVYZAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB4000GVYZA","target_guid":"002340a5-4d00-3442-3030-304756595a41","type":"sata"},{"id":"MB6000GVYZB","target_guid":"002340a5-4d00-3642-3030-304756595a42","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:51:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYZB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GDUNU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304744554e55","Version":"HPG4"},{"DeviceName":"MB2000GDUNV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304744554e56","Version":"HPG4"},{"DeviceName":"MB3000GDUPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304744555041","Version":"HPG4"},{"DeviceName":"MB4000GDUPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAHARRG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304744555042","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA&nbsp;and MB4000GDUPB drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Firmware cannot be downgraded to HPG3 after updating to HPG4.</li>\n</ul>\n"}],"files":[{"bytes":"16940219","datemodified":"2021-08-26T15:29:34","file_list":["/CP048342_BUILD_2.data","/CP048342.vmexe","/CP048342.vmexe64","/CP048342.vmfile","/CP048342_VMw.zip","/CP048342.xml","/payload.json","/CP048342_VMw.zip/index.xml","/CP048342_VMw.zip/vendor-index.xml","/CP048342_VMw.zip/metadata.zip","/CP048342_VMw.zip/vib20/CP048342/HPE_bootbank_CP048342_HPG4.2-7.0.0.15843807.vib","/CP048342_VMw.zip/metadata.zip/vendor-index.xml","/CP048342_VMw.zip/metadata.zip/vmware.xml","/CP048342_VMw.zip/metadata.zip/vibs/CP048342--2210292570397044906.xml","/CP048342_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048342_HPG4.2-7.0.0.15843807.xml"],"md5sum":"7efd88a41ac314aa269a545c03bb22ed","name":"CP048342.zip","release":"2021-08-26T15:24:31","revision":"0","sha1sum":"48d92b5d93c7cb726c1b1d116e662abcbf72e304","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304744554e55","002340a5-4d00-3242-3030-304744554e56","002340a5-4d00-3342-3030-304744555041","002340a5-4d00-3442-3030-304744555042"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048342","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"9635a1b56d544167b79937e43283b144","version":"4dd2ac0b3e0f418cbf8b5b67fe68effa"},"installation":{"command":"CP040506.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GDUNU, MB2000GDUNV, MB3000GDUPA and MB4000GDUPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB1000GDUNU、MB2000GDUNV、MB3000GDUPA、およびMB4000GDUPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GDUNU","target_guid":"002340a5-4d00-3142-3030-304744554e55","type":"sata"},{"id":"MB2000GDUNV","target_guid":"002340a5-4d00-3242-3030-304744554e56","type":"sata"},{"id":"MB3000GDUPA","target_guid":"002340a5-4d00-3342-3030-304744555041","type":"sata"},{"id":"MB4000GDUPB","target_guid":"002340a5-4d00-3442-3030-304744555042","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T14:41:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB2000GDUNV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GDUPA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GDUPB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GDUNU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300094","languages":[{"lang":"fr","x_late":"Pilote - Jeu de puces"},{"lang":"en","x_late":"Driver - Chipset"},{"lang":"cn","x_late":"驱动程序 - 芯片组"},{"lang":"tw","x_late":"驅動程式 ─ 晶片組"},{"lang":"de","x_late":"Treiber - Chipsatz"},{"lang":"ko","x_late":"드라이버 – 칩셋"},{"lang":"ja","x_late":"ドライバ - チップセット"},{"lang":"es","x_late":"Controlador - Conjunto de chips"}]}],"description":[{"lang":"en","x_late":"This component installs driverless INFs to identify devices in the processor and chipset."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"612144","datemodified":"2021-12-21T07:02:14","file_list":["cp050604.xml","cpqsetup.exe","installer.dll","pnp/","pnp/cannonlake-h.cat","pnp/CannonLake-HSystem.inf","pnp/CannonLake-HSystemThermal.inf","pnp/coffeelake.cat","pnp/CoffeelakeSystem.inf","pnp/null_heci.cat","pnp/NULL_HECISystem.inf"],"md5sum":"b3e815e1fd8facccaa4628dd9f44ec91","name":"cp050604.exe","release":"2021-12-21T07:00:46","revision":"0","sha1sum":"87e856aead3929dcfd2e10dd2389ba724d9e6c5d","size":"597KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"type_of_change":"0","version":"10.1.18807.8279"}],"id":{"product":"d6464fc039cd4a77b22febd8762dca03","version":"caf098abeed2499cbdcdf48d9c9c9be7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.\n<p>From that drive and directory, execute the downloaded file. \n<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。\n<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows"},{"lang":"ja","x_late":"Microsoft Windows用インテルXeon E-22xxプロセッサーの識別子"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-21T06:47:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2022</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Fixed version control issues</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"installer.dll","sw_key_expectedpath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD and EH0600JEDHE"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0300JEDHC、EH0450JEDHDおよびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17267960","datemodified":"2021-08-30T07:15:55","file_list":["/CP048293_BUILD_2.data","/CP048293.vmexe","/CP048293.vmexe64","/CP048293.vmfile","/CP048293_VMw.zip","/CP048293.xml","/payload.json","/CP048293_VMw.zip/index.xml","/CP048293_VMw.zip/vendor-index.xml","/CP048293_VMw.zip/metadata.zip","/CP048293_VMw.zip/vib20/CP048293/HPE_bootbank_CP048293_HPD4.2-7.0.0.15843807.vib","/CP048293_VMw.zip/metadata.zip/vendor-index.xml","/CP048293_VMw.zip/metadata.zip/vmware.xml","/CP048293_VMw.zip/metadata.zip/vibs/CP048293-4570890945673392922.xml","/CP048293_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048293_HPD4.2-7.0.0.15843807.xml"],"md5sum":"24bf4770951e00774d0d14919ca4c975","name":"CP048293.zip","release":"2021-08-30T07:11:18","revision":"0","sha1sum":"5507357e4dbe57f95f428b9833c492b3f483f583","size":"16MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048293","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"10fb5093c8b24e83a8541c8c40bc7e15","version":"e8f15d57622d4e59bc754896a76d9d14"},"installation":{"command":"CP039423.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T08:18:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2022 for the HPE Smart Storage SR100i Gen10 Plus SW RAID"},{"lang":"ja","x_late":"このドライバーは、Windows Server 2022でのHPE SmartストレージSR100i Gen10 Plus SW RAIDをサポートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1733720","datemodified":"2022-01-12T14:57:48","file_list":["cp049977.xml","cpqsetup.exe","generic.dll","install.xml","smartdq2.cat","SmartDQ2.inf","SmartDQ2a.sys","SmartDQ2co002.dll","SmartDQ2p.sys","SmartDQ2r.sys"],"md5sum":"5eb7da255613529304a2e050b850cc93","name":"cp049977.exe","release":"2022-01-12T14:54:26","revision":"0","sha1sum":"ead666fa34dd192059bf7e5332d3706928b0a505","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec14b13c05"],"type_of_change":"1","version":"1010.124.90.1233"}],"id":{"product":"335ce4a972624f62a9d5631fe39baa81","version":"abd526decbd34ee699bd055524bcb3da"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Storage SR100i Gen10 Plus SW RAID Driver for Windows Server 2022"},{"lang":"ja","x_late":"HPE SmartストレージSR100i Gen10 Plus SW RAIDドライバーfor Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"027F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f1590027f","type":"pci","ven":"103C"},{"dev":"A256","subdev":"02F4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159002f4","type":"pci","ven":"8086"},{"dev":"A206","subdev":"02F2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159002f2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T02:50:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Correct NVMe link width information in SSA.</li>\n\t<li>Fix background surface scan may not be started for a volume configured with SSD SmartPath.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>new version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"SmartDQ2a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array and Smart RAID controller driver component for VMware vSphere 6.7, for use with HPE Smart Update Manager."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"169435","datemodified":"2021-08-11T01:34:57","file_list":["/cp047415.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/index.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/vendor-index.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/metadata.zip","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/vib20/smartpqi/MSCC_bootbank_smartpqi_67.4150.0.119-1OEM.670.0.0.8169922.vib","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/metadata.zip/vibs/smartpqi--7451713705348882394.xml","/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922-offline_bundle-18384766.zip/metadata.zip/bulletins/Microchip-smartpqi_67.4150.0.119-1OEM.670.0.0.8169922.xml"],"md5sum":"14de550bacb715a26d6d7d1768586886","name":"cp047415.zip","release":"2021-08-11T01:34:10","revision":"0","sha1sum":"7226fc1fa6a779b598c050be1784d5f51c9c6867","size":"165KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"smartpqi","version":"67.4150.0.119-1OEM.670.0.0.8169922"}]}],"id":{"product":"b3d438df80104989af5f67cfa3d9e0ea","version":"00cb8b9732d04d8f92afa0918c1274d3"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 Smart Array and Gen10 Plus Smart RAID Controller Driver for VMware vSphere 6.7 (Driver Component)."}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T11:42:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>.Added&nbsp;support&nbsp;to the HPE&nbsp;SR932i-p and SR416-a&nbsp;Gen10 Plus&nbsp;Controllers.</p>\n","latest_fixes_x_late":"<ul>\n\t<li>HBA mode SATA drive is identified as new device after reinserting drive in a different slot. The fix will work if SATA WWN Unique ID feature is enabled in the driver module parameters.</li>\n\t<li>A PSOD issue during array deletion, when frequently create/delete array.</li>\n\t<li>A PSOD issue might be observed while deleting a logical drive with pending IO.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi:67.4150.0.119-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.3082.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.3082.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.3082.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するIntel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2&nbsp;&nbsp;Adapter</td>\n\t\t\t<td>8000B437</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>8.50</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter</td>\n\t\t\t<td>8000B735</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>8.50</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T&nbsp;&nbsp;Adapter</td>\n\t\t\t<td>80001099</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3&nbsp;Adapter</td>\n\t\t\t<td>80001097</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel(R) I350 Gigabit Network Connection (2-port)</td>\n\t\t\t<td>8000108E</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>Intel(R) I350 Gigabit Network Connection (4-port)</td>\n\t\t\t<td>8000108F</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.3082.0 includes: Boot Agent: 1GbE - v1.5.89,&nbsp;Boot Agent I40E -&nbsp;v1.1.31&nbsp;&amp; UEFI Drivers: 1GbE - v9.7.06, 40 gigabit driver - v4.8.08.</p>\n"}],"files":[{"bytes":"4512863","datemodified":"2021-11-04T06:52:09","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/CP049897.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/CP049897.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000108E.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000108E.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000108F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000108F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_X710DA2_8p50_CFGID7p2_K97470_8000B735.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_X710DA2_OCP3_8p50_CFGID7p2_K97342_8000B734.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_i350T4_K68277_80001099.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_i350T4_K68277_80001099.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001097.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001097.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.23.50-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049897.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049897.scexe"],"md5sum":"acefcb4418a0aa7d49152b2e271082cf","name":"firmware-nic-is-intel-1.23.50-1.1.x86_64.rpm","release":"2021-11-04T06:41:36","revision":"0","sha1sum":"3822920b3af98d69460e925822c0d96c74bf04cc","size":"4MB","target_guids":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"type_of_change":"1","version":"1.23.50"}],"id":{"product":"eeaaff922a754e178b46a3315fd0a64a","version":"1d771ce0d60d4c53a19458560585defc"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP047005.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP047005.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP044895<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP047005.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong><em><strong><em><strong><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>次のコマンドを使用して、NICファームウェアをインストールします：  <em>rpm -ivh <rpm_filename>.rpm.  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<br />\n\t<li>CP047005.scexeスクリプトは 'scexe-compat' フォルダーにあります。詳細については、firmware-nic-*フォルダーのCP047005.txtファイルを参照してください。firmware-nic-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<br />\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu'のロケーションにある<em>./</em>CP044895<em>.scexe</em>（または）</li>\n\t\t<li>firmware-nic-*ロケーションの<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>rpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li>\n</ul>\n\n<p><br />\n<em><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></em></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<br />\n\t<li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./hpsetup</em>を実行してファームウェアをアップデートします。firmware-nic-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<br />\n\t<li> </li>\n</ul>\n\n<p><em><strong>追加情報:</strong></em></p>\n\n<ul>\n\t<li>特定のシナリオでは、EPROMをアップデートした後にシステムを再起動して、アダプターのフラッシュROM（OROM）をアップデートするためにコンポーネントの再実行を要求されることがあります。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにある\"CP047005.log\"ファイルに保存されます。</li>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアrpmパッケージのインストール（rpm -ivh）は、アダプターのファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。アダプターのファームウェアをアップデートするには、上記の手順に従う必要があります。 </li>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ja","x_late":"Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-01T07:02:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4 and SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"}],"sw_keys":[{"name":"IS_INTEL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2019用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1997088","datemodified":"2021-12-07T09:40:00","file_list":["cp050320.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"c9270521a6b482ada8288672da317486","name":"cp050320.exe","release":"2021-12-07T09:25:18","revision":"0","sha1sum":"5bf0649bdeed8dc1d09e185c75f8515f20726217","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"6d1e58e8f89340958bf7818046e9b7c7","version":"6a12235813ce43e5826f4816f1ae8ddb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue where mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue where incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue where prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 7 Update 9 x86_64."},{"lang":"ja","x_late":"この製品は、Red Hat Enterprise Linux 7アップデート9 x86_64下で実行されるサポートされたHPE Broadcom NetXtreme-Eアダプターカードに関するRoCE（RDMA over Converged Ethernet）ライブラリを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25137","datemodified":"2021-10-01T18:16:31","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-219.0.8.0.so","./usr/lib64/libbnxt_re-rdmav22.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"da73aecf11f9c4e5cdc71facb6c603d5","name":"libbnxt_re-219.0.8.0-rhel7u9.x86_64.rpm","release":"2021-10-01T18:07:57","revision":"0","sha1sum":"f6645a57f19ea4186c7158f988b8f46d91d30df1","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"219.0.8.0"}],"id":{"product":"1ff674590ea54295a0a402207a50999a","version":"83a4a209efec44f195ba1458a32c4634"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"},{"lang":"ja","x_late":"<p style=\"text-align:left\">rpm -ivh <bnxt_rooce >.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">インボックスライブラリと競合する可能性のあるHPE Broadcom RoCEライブラリをインストールまたはアップデートするときは、--forceまたは--replacefilesオプションを使用します</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 7 Update 9"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E RoCEライブラリfor Red Hat Enterprise Linux 7 Update 9"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HardWare Resource Manager(HWRM) timeouts observed when firmware undergoes reset in the ethernet interface down state.</li>\n\t<li>This product addresses an issue where Receive (RX) packet crash under heavy traffic.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"12.8.528.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.528.21"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5855385","datemodified":"2022-01-21T03:39:25","file_list":["/CP049954_BUILD_2.data","/CP049954.vmexe","/CP049954.vmexe64","/CP049954.vmfile","/CP049954_VMw.zip","/CP049954.xml","/payload.json","/CP049954_VMw.zip/index.xml","/CP049954_VMw.zip/vendor-index.xml","/CP049954_VMw.zip/metadata.zip","/CP049954_VMw.zip/vib20/CP049954/HPE_bootbank_CP049954_2022.03.01.2-6.7.0.7535516.vib","/CP049954_VMw.zip/metadata.zip/vendor-index.xml","/CP049954_VMw.zip/metadata.zip/vmware.xml","/CP049954_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049954_2022.03.01.2-6.7.0.7535516.xml","/CP049954_VMw.zip/metadata.zip/vibs/CP049954-7880566207309246738.xml"],"md5sum":"ab11e9f509e84cae7abeeb09abf5fc81","name":"CP049954.zip","release":"2022-01-21T03:35:42","revision":"0","sha1sum":"9436dc1e95a9ec4305b9c466d4fb8b5659d1c5d2","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"CP049954","version":"2022.03.01.2-6.7.0.7535516"}]}],"id":{"product":"ebf7ff9c6812476d970ce7cd8ffbe7b6","version":"5fb56193556c4879bf4341fc65e881b7"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />\nオフライン：</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li>\n</ul>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li>\n\t<li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p> </p>\n\n<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p> </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li>\n\t<li>同じディレクトリからSmartコンポーネントをunzipします。\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li>\n\t<li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li>\n\t<li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li>\n\t<li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/<CPxxxxxx></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Smartコンポーネントの指示に従います</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  6.7"},{"lang":"ja","x_late":"HPEファームウェアフラッシュfor Emulexファイバーチャネルホストバスアダプターfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1195336","datemodified":"2021-08-12T04:11:52","file_list":["cp047041.xml","cpqsetup.exe","cp_data.xml","e1r65x64.cat","e1r65x64.din","e1r65x64.inf","e1r65x64.sys","e1rmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInE1R.dll"],"md5sum":"5a9e74c2e6d0b88b23832eaa043d5112","name":"cp047041.exe","release":"2021-08-12T03:58:06","revision":"0","sha1sum":"bf7b05dbc1de94b6ff00cdb52aedfb20fb44a18f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac"],"type_of_change":"0","version":"12.16.4.1"}],"id":{"product":"2131145ed95b459da9bb06449e0c1401","version":"fdccb4a171f5489893e2160d6ac6acad"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i350 Driver for Windows Server 2016"},{"lang":"ja","x_late":"Intel i350ドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"e1r65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6053053","datemodified":"2021-07-23T07:21:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/CP048135.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/HLIBRHHaseFG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cc819d4bff-HPG5-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048135.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048135.scexe"],"md5sum":"2e9e3ac40fa71172fc9387ba328e5927","name":"firmware-hdd-cc819d4bff-HPG5-7.1.x86_64.rpm","release":"2021-07-23T07:09:15","revision":"0","sha1sum":"65bab66c60cf0d85b7f6b8c571aa00a3a21a295b","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"ff5f0967b6c84e77920662313dc42a52","version":"4aa47182229f4436b94105f6e6ff352e"},"installation":{"command":"CP040327.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T11:53:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Blade ProLiant Intel Gigabit Ethernet NICs ROM images running under running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE Blade ProLiant Intel Gigabit Ethernet NIC ROMイメージをアップグレードするためのユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"9249571","datemodified":"2021-03-31T19:54:09","file_list":["/CP045076_BUILD_10.data","/CP045076.vmexe","/CP045076.vmexe64","/CP045076.vmfile","/CP045076_VMw.zip","/CP045076.xml","/payload.json","/CP045076_VMw.zip/index.xml","/CP045076_VMw.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip","/CP045076_VMw.zip/vib20/CP045076/HPE_bootbank_CP045076_1.2.2.10-7.0.0.15843807.vib","/CP045076_VMw.zip/metadata.zip/vendor-index.xml","/CP045076_VMw.zip/metadata.zip/vmware.xml","/CP045076_VMw.zip/metadata.zip/vibs/CP045076--3289781217789523104.xml","/CP045076_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045076_1.2.2.10-7.0.0.15843807.xml"],"md5sum":"a79a420777f38e6bb0a58f35d2ea57a6","name":"CP045076.zip","release":"2021-03-31T19:51:05","revision":"0","sha1sum":"f93fe83298834a220ed43d37ef5bb5331bc5da6f","size":"8MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.2.3","vib_list":[{"name":"CP045076","version":"1.2.2.10-7.0.0.15843807"}]}],"id":{"product":"cbe5961cc6764856bfc9b1b69b78fe4d","version":"51c86cb16f4e4611853f4692b84ff444"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"12.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"15.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"7.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec05844b56","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.6.4-1","description":"HPE Blade Intel ixgbe Driver version 5.6.4-1 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.600.0.0.2768847","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.600.0.0.2768847 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"6.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.7.20-1OEM.670.0.0.8169922","description":"HPE Blade Intel ixgben Driver version 1.7.20-1OEM.670.0.0.8169922 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active","OSVersion":{"name":"VMWare","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.8.9.0-1OEM.700.1.0.15525992","description":"HPE Blade Intel ixgben Driver version 1.8.9.0-1OEM.700.1.0.15525992 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<br />\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<br />\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<br />\n\t<li>Install the VMware component.\n\t<ol>\n\t\t<li>For ESXi 7.0 targets:&nbsp;<em>esxcli&nbsp; software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example:<em> &quot;</em>esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<br />\n\t\t<li>For ESXi 6.x targets:&nbsp;<em>esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip</em>. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<br />\n\t<li>Execute the component with the command set options&nbsp; s, -f, -e, -g, &nbsp;etc. if required. When execution is complete&nbsp;the flash engine will have&nbsp;performed the flash operation as directed.</li>\n\t<br />\n\t<li>Clean up the Smart Component:\n\t<ol>\n\t\t<li>Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<br />\n\t\t<li>To clean up the Smart Component:\n\t\t<ol>\n\t\t\t<li>For ESXi 7.0 targets: <em>esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>For ESXi 6.x targets: <em>esxcli software vib remove &ndash;n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>Remove the directories associated with CPxxxxxx: <em>rm -rf&nbsp;/opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<br />\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<br />\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<br />\n\t<li>VMwareコンポーネントをインストールします。\n\t<ol>\n\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli  software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：<em></em>\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<br />\n\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip</em> （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<br />\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<br />\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ol>\n\t\t<li>/opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<br />\n\t\t<li>Smartコンポーネントをクリーンアップするには：\n\t\t<ol>\n\t\t\t<li>ESXi 7.0ターゲットの場合：<em>esxcli software component remove –n Smart-Component-CPxxxxxx</em></li>\n\t\t\t<br />\n\t\t\t<li>ESXi 6.xターゲットの場合：<em>esxcli software vib remove –n CPxxxxxx</em></li>\n\t\t</ol>\n\t\t</li>\n\t\t<br />\n\t\t<li>CPxxxxxxに関連付けられているディレクトリを削除します：<em>rm -rf /opt/Smart_Component/CPxxxxxx</em></li>\n\t</ol>\n\t</li>\n\t<br />\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for VMware"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティfor VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi&nbsp;7.0.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware vSphere 7.0 U1.<br />\nThis product now supports VMware vSphere 6.7 U3.<br />\nThis product now supports VMware vSphere 6.5 U3.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"INTEL_BL","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2016で動作しているIntel i40eaおよびIntel i40eb Ethernet NIC用のHPE iavfドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1442248","datemodified":"2021-01-09T07:55:37","file_list":["cp045011.xml","cpqsetup.exe","cp_data.xml","iavf65.cat","iavf65.din","iavf65.inf","iavf65.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"cea7da9999e8eb9b24eea21fc4ed6428","name":"cp045011.exe","release":"2021-01-09T07:37:04","revision":"0","sha1sum":"96e18c5bee40225ff648f733e4148921304a6aaf","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc729bb39"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"d480f616863140bd906bb9e3934e35ae","version":"51c863ae26a042a3bf499fe0420670f2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library iavfmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"iavf65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers.  This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。  このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。\nerrataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。  だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。  そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p>-</p>\n"}],"files":[{"bytes":"72608","datemodified":"2022-01-25T13:34:20","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"081952e296aaf279cf67b6bce2285bc7","name":"smartpqi-kmp-default-2.1.16-030.sles12sp5.x86_64.rpm","release":"2022-01-25T13:29:19","revision":"0","sha1sum":"57cf2114c1613d1bb1d7d01e3abd9ea73a5644b1","size":"70KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.16-030"},{"bytes":"74026","datemodified":"2022-01-25T13:35:27","file_list":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"md5sum":"64d30dfd4a31dd1a7063ab3e55d30550","name":"smartpqi-kmp-default-2.1.16-030.sles12sp4.x86_64.rpm","release":"2022-01-25T13:29:19","revision":"0","sha1sum":"a0975bd008affd6d3e169b96a3592868c5f1ea08","size":"72KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"type_of_change":"1","version":"2.1.16-030"}],"id":{"product":"9225c9596a464443833dcfea70680689","version":"215de90ef4c940c5834da08208cb7b66"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh smartpqi-kmp-default-&lt;version&gt;.sles12&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e smartpqi-kmp-default-&lt;version&gt;.sles12&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 12 (64-bit)"},{"lang":"ja","x_late":"HPE ProLiant Gen10 Smartアレイコントローラー(64ビット)ドライバーfor SUSE LINUX Enterprise Server 12 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"},{"id":"ven_0x1590&dev_0x02db","target_guid":"","type":"pcie"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T15:47:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where duplicate device nodes for Ultrium tape drive and medium changer are being created.</li>\n\t<li>Fixed an issue where the OS boot could fail during logical volume rebuild.</li>\n\t<li>Fixed an issue to avoid failing IOs for devices which are offline.</li>\n\t<li>Fixed an issue where request_irq failed during system hibernation.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"smartpqi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"HPE Smart Array controller driver component for VMware vSphere 6.5, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するHPE Smartアレイコントローラードライバーコンポーネント for VMware vSphere 6.5。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"171147","datemodified":"2021-08-10T19:10:56","file_list":["/cp047414.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/index.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/vendor-index.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/metadata.zip","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/vib20/smartpqi/MSCC_bootbank_smartpqi_65.4150.0.119-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-smartpqi-65.4150.0.119.xml","/VMW-ESX-6.5.0-smartpqi-65.4150.0.119-offline_bundle-18379836.zip/metadata.zip/vibs/smartpqi-6417596934412183371.xml"],"md5sum":"0279e731d68e6bc4127c59807a72616d","name":"cp047414.zip","release":"2021-08-10T19:10:07","revision":"0","sha1sum":"7fb1033bccd9e5feba36a5f0731184a860451e57","size":"167KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"type_of_change":"1","version":"2021.09.01","vib_list":[{"name":"smartpqi","version":"65.4150.0.119-1OEM.650.0.0.4598673"}]}],"id":{"product":"50c36908ae914a07af064f02b440965e","version":"15383031138e41c2a381f70ba9e40885"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":100,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>HPE USB Key Creator Utility</u></a>.</li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hp/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hp/swpackages and ./hpsum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n\n<p><br />\n&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン：</strong></p>\n\n<ul>\n\t<li> <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>HPE USB Key Creator Utility</u></a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hp/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li> CD /hp/swpackagesおよび./hpsum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> 更新されるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n\n<p><br />\n </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 Smart Array Controller Driver for VMware vSphere 6.5 (Driver Component)."}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-04-30T11:33:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>HBA mode SATA drive is identified as new device after reinserting drive in a different slot. The fix will work if SATA WWN Unique ID feature is enabled in the driver module parameters.</li>\n\t<li>A PSOD issue during array deletion, when frequently create/delete array.</li>\n\t<li>A PSOD issue might be observed while deleting a logical drive with pending IO.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"smartpqi:65.4150.0.119-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300100","languages":[{"lang":"fr","x_late":"Pilote - Stockage"},{"lang":"en","x_late":"Driver - Storage"},{"lang":"cn","x_late":"驱动程序 - 存储"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置"},{"lang":"de","x_late":"Treiber - Speicher"},{"lang":"ko","x_late":"드라이버 - 스토리지"},{"lang":"it","x_late":"Driver - Memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ"},{"lang":"es","x_late":"Controlador - Almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver supports Windows Server 2016 and Windows Server 2019 for the HPE Smart Array S100i SR Gen10 SW RAID"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1637240","datemodified":"2021-09-03T13:34:33","file_list":["cp048017.xml","cpqsetup.exe","generic.dll","install.xml","smartdq.cat","SmartDQ.inf","SmartDQa.sys","SmartDQco002.dll","SmartDQp.sys","SmartDQr.sys"],"md5sum":"5bae2a6fa93306c62a8c40ad0d9301dc","name":"cp048017.exe","release":"2021-09-03T13:32:41","revision":"0","sha1sum":"f603faedf22b3c059f3ddee75cee1cd1d59be923","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59"],"type_of_change":"1","version":"106.12.6.0"}],"id":{"product":"d2e7aa5024a34aef908b398a3c4e0625","version":"86a4d38eba634fe2a9d85c8d34a6d9e2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.</p>\n\n<p>Select &quot;Install&quot; to start extracting to a temporary location on the hard drive.</p>\n\n<p>Click the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p><strong>Note:&nbsp;</strong>Per Microsoft kb #2031031(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>), users cannot remove/unmount a USB until after the install has finished.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをテンポラリディレクトリにコピーし、ダブルクリックして実行します。</p>\n\n<p>インストールを選択して、ハードディスクのテンポラリディレクトリに解凍します。</p>\n\n<p>インストールボタンをクリックしてドライバーインストールを実行します。</p>\n\n<p><strong>注: </strong>Microsoft kb #2031031について(<a href=\"https://support.microsoft.com/en-us/kb/2931031\">https://support.microsoft.com/en-us/kb/2931031</a>)、 ユーザーはUSBインストールが終わるまではUSBを削除したり、取り外したりすることはできません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Smart Array S100i SR Gen10 SW RAID Driver for Windows Server 2016 and Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-19T09:56:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for AMD.</p>\n","latest_fixes_x_late":"<p>Addressed an issue where the HPE Smart Array s100i Software RAID may experience potential data inconsistency during initial configuration or operation of a RAID volume configured in RAID 0/1/5/10 Fault Tolerant Modes.&nbsp;</p>\n\n<p style=\"margin-left:48px\">This issue does not impact systems configured in other RAID configurations such as RAID 0 or 1. This issue does not impact systems that have not enabled Smart Array s100i support.</p>\n\n<ul>\n\t<li>For additional information, reference&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00097734en_us\" style=\"color:#0563c1; text-decoration:underline\" target=\"_blank\">Customer Bulletin a00097734en_us</a>.</li>\n</ul>\n\n<p style=\"margin-left:48px\"><strong>IMPORTANT INFORMATION:</strong></p>\n\n<ul>\n\t<li>An array configured with a single RAID 0 logical drive is NOT affected.</li>\n\t<li>An array configured with a single RAID 1 logical drive is NOT affected.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Added support for AMD.</p>\n","curr_fixes_x_late":"<p>Addressed an issue where the HPE Smart Array s100i Software RAID may experience potential data inconsistency during initial configuration or operation of a RAID volume configured in RAID 0/1/5/10 Fault Tolerant Modes.&nbsp;</p>\n\n<p style=\"margin-left:48px\">This issue does not impact systems that have not enabled Smart Array s100i support.</p>\n\n<ul>\n\t<li>For additional information, reference&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00097789en_us\">Customer Bulletin a00097789en_us. </a></li>\n</ul>\n\n<p style=\"margin-left:48px\"><strong>IMPORTANT INFORMATION:</strong></p>\n\n<ul>\n\t<li>An array configured with a single RAID 0 logical drive is NOT affected.</li>\n\t<li>An array configured with a single RAID 1 logical drive is NOT affected.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE Apollo k6000 Chassis"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"SmartDQa.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_CQDA2_OCP_3p00_NCSIwPLDMoMCTP_800095B6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-CQDA2 OCP3 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-CQDA2 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter</td>\n\t\t\t<td>800095B6</td>\n\t\t\t<td>1.3082.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>he combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"}],"files":[{"bytes":"10519625","datemodified":"2021-11-10T01:55:06","file_list":["HPE_E810_CQDA2_OCP_3p00_NCSIwPLDMoMCTP_800095B6.HPb","HPE_E810_CQDA2_OCP_3p00_NCSIwPLDMoMCTP_800095B6.xml","payload.json"],"md5sum":"400acc2a00a3039afbd86e20ddd8ae2e","name":"HPE_E810_CQDA2_OCP_3p00_NCSIwPLDMoMCTP_800095B6.fwpkg","release":"2021-11-10T01:51:35","revision":"0","sha1sum":"314253b75a454fca0fdd5be759ea12753340cbd5","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159280860006"],"type_of_change":"1","version":"3.00"}],"id":{"product":"dc41774861a945f28d388059e656b2ca","version":"6546b19012704c78ac3dbb850ec8d421"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-CQDA2 Ethernet 100Gb 2ポートQSFP28 OCP3アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-03T10:22:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product correct an issue which the Operation failed error in POST when Breakout cable connected.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_CQ2OCP_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB&nbsp;and EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None.</p>\n"}],"files":[{"bytes":"3638856","datemodified":"2021-07-24T06:48:25","file_list":["cp048482.xml","cpqsetup.exe","HCFLRCD5.rel","payload.json","setup.dll"],"md5sum":"641f8908d301f76163b31aea05f69728","name":"cp048482.exe","release":"2021-07-24T06:41:04","revision":"0","sha1sum":"f937be947ea8b37f554fb4149303fda15907c71a","size":"3MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"5d9285c19f4844c191173be5431c0cba","version":"dfa9fa7533b74a77afc01c27842b0d31"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T04:35:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"5727E0D6-F37B-447D-A9E4-5A7FB0B9DC8A","Devices":{"Device":[{"DeviceName":"Intel Optane DC Persistent Memory","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_bwva1_2.2.0.1553_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805dd01c-eb5a-1e76-8089-004080897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory 128 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_bwva1_2.2.0.1553_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805dd01c-eb5a-1e76-8089-524580897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory 256 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_bwva1_2.2.0.1553_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805dd01c-eb5a-1e76-8089-a74a80897b09","Version":"2.2.0.1553"},{"DeviceName":"Intel Optane DC Persistent Memory 512 GB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"fw_bwva1_2.2.0.1553_rel.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805dd01c-eb5a-1e76-8089-fc4f80897b09","Version":"2.2.0.1553"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This firmware package provides firmware for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"306015","datemodified":"2021-06-21T07:37:44","file_list":["dcpmm_02.02.00.1553.xml","fw_bwva1_2.2.0.1553_rel.bin","payload.json"],"md5sum":"260654904562bc21ddcc1a0ef39dcbf9","name":"dcpmm_02.02.00.1553.fwpkg","release":"2021-06-21T07:36:16","revision":"0","sha1sum":"e3d73c0940acd71144d0768184f990572c922259","size":"298KB","target_guids":["805dd01c-eb5a-1e76-8089-004080897b09","805dd01c-eb5a-1e76-8089-524580897b09","805dd01c-eb5a-1e76-8089-a74a80897b09","805dd01c-eb5a-1e76-8089-fc4f80897b09"],"type_of_change":"1","version":"02.02.00.1553"}],"id":{"product":"9888843dad4d483b96ce3979ce9bc528","version":"46c2df4b39a44854a720a0d5f86edfc9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the <strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n\n<p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration-line: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Intel Corporation"}],"name":[{"lang":"en","x_late":"Firmware package for HPE Persistent Memory featuring Intel Optane DC Persistent Memory on HPE Gen10 Plus Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release of Firmware for HPE Persistent Memory for Gen10 Plus Servers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue that three different capacities of Intel Optane DC Persistent Memory are identifiable&nbsp;with three individual device GUID.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"DCPMEM-Gen10","sw_key_expectedpath":"firmware:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanox ConnectX-4、ConnectX-5、およびConnectX-6アダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE（RDMA over Converged Ethernet）ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1787405","datemodified":"2021-12-14T04:16:07","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/compat","./lib/modules/5.3.18-57-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-57-default/updates/drivers","./lib/modules/5.3.18-57-default/updates/drivers/base","./lib/modules/5.3.18-57-default/updates/drivers/base/auxiliary.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-57-default/updates/drivers/net","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-57-default/updates/net","./lib/modules/5.3.18-57-default/updates/net/9p","./lib/modules/5.3.18-57-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/mlxdevm","./lib/modules/5.3.18-57-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/5.3.18-57-default/updates/net/rds","./lib/modules/5.3.18-57-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/smc","./lib/modules/5.3.18-57-default/updates/net/smc/smc.ko","./lib/modules/5.3.18-57-default/updates/net/smc/smc_diag.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"4fb2bd657dd0932a6baf2098b70bb37b","name":"mlnx-ofa_kernel-kmp-default-5.5_k5.3.18_57-OFED.5.5.1.0.3.1.sles15sp3.x86_64.rpm","release":"2021-12-14T03:04:06","revision":"0","sha1sum":"6b91daffa3e19b1fbdf6382aea73eab217bee21e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"},{"bytes":"1425514","datemodified":"2021-12-14T04:14:58","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/70-persistent-ipoib.rules","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/82-net-setup-link.rules","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/mlnx_bf_configure_ct","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/include/mellanox/dpcp.h","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/05rdma","./usr/lib/dracut/modules.d/05rdma/module-setup.sh","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python2.7/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/mlnx_tools-5.2.0-py3.6.egg-info","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libdpcp.so","./usr/lib64/libdpcp.so.1","./usr/lib64/libdpcp.so.1.1.17","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.37.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.14.37.0","./usr/lib64/libibverbs/libmlx5-rdmav34.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.21.37.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.3.37.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.4.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/dpcp","./usr/share/doc/packages/dpcp/README","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.4.0","./usr/share/doc/packages/libvma-9.4.0/CHANGES","./usr/share/doc/packages/libvma-9.4.0/README","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/COPYING.BSD_FB","./usr/share/doc/packages/rdma-core/COPYING.BSD_MIT","./usr/share/doc/packages/rdma-core/COPYING.GPL2","./usr/share/doc/packages/rdma-core/COPYING.md","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/dpcp","./usr/share/licenses/dpcp/LICENSE","./usr/share/licenses/libvma","./usr/share/licenses/libvma/COPYING","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"bc10edfaf6b5dd6d3543433547ba3077","name":"mlnx-ofa_kernel-5.5-OFED.5.5.1.0.3.1.sles15sp3.x86_64.rpm","release":"2021-12-14T03:04:06","revision":"0","sha1sum":"af5dcbc2271be180e62b987795de7359e8927f2f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"5.5"}],"id":{"product":"3c1cedac275a43ba93bd2bb1e94c8930","version":"6ae994f2c1764c0a9d670d34edef5b16"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-5.5&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 5.3.18-57-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-5.5-OFED.5.5.0.4.4.1.sles15sp3.x86_64.rpm mlnx-ofa_kernel-kmp-default-5.5_k5.3.18_57-OFED.5.5.0.4.4.1.sles15sp3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Mellanox ConnectX-4, ConnectX-5 and ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP3 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE（RDMA over Converged Ethernet）ドライバーfor Mellanox ConnectX-4、ConnectX-5、ConnectX-6 Adapters for SUSE LINUX Enterprise Server 15 SP3 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-10T06:13:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>MLNX OFED v5.4&nbsp;contains the following changes and new features:</strong></p>\n\n<p><strong>For ConnectX-4 Adapters:</strong></p>\n\n<ul>\n\t<li>Updated mlx5 driver to use auxiliary bus in order to integrate different driver components into driver core and optimize module load/unload sequences.</li>\n\t<li>WJH (What Just Happened) in NICs: WJH allows for visibility of dropped packets (i.e., receiving notice of drop counters increase, seeing content of the dropped packets, debugging, and more). WJH is a service in devlink context and it is already implemented in the switch.</li>\n\t<li>Note: processing dropped packets (even for visibility purposes) may cause a degradation in performance and leaves the driver vulnerable for malicious attacks. The feature is disabled by default.</li>\n\t<li>Supported traps:</li>\n\t<li>VLAN mismatch: existing generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong VLAN tag</li>\n\t<li>DMAC mismatch: new generic trap DEVLINK_TRAP_GENERIC_ID_DMAC_MISMATCH Traps received packets with wrong destination MAC</li>\n\t<li>Added support for enabling Relaxed Ordering for Kernel ULPs. Using relaxed ordering can improve performance in some setups. Since kernel ULPs are expected to support RO, it is enabled for them by default so they can benefit from it.</li>\n</ul>\n\n<p><strong>For ConnectX-4 Adapters and above:&nbsp;</strong></p>\n\n<ul>\n\t<li>In MLNX_OFED 5.4 GA, ConnectX-4/5/6 Ethernet network interfaces are now provided with permanent names. Prior to this release, the default interface names were provided by the kernel and udevd (ethX) remained as-is. From this release onwards, interface names are generated via new udevd rules. The generated names are now predictable, and the default names are automatically renamed to the predictable names by the udevd daemon, according to udev rules files installed by OFED.</li>\n</ul>\n\n<p><strong>For ConnectX-5 Adapters and above:</strong></p>\n\n<ul>\n\t<li>Support to allow OVS (OpenVSwitch) kernel to support up to 128 matches (groups) per table and 16M entries per group.</li>\n\t<li>Offload ct_state flags rpl, inv, and rel.</li>\n\t<li>For rpl, support was added for both set and not set matching offload (i.e., +rpl and -rpl).</li>\n\t<li>For inv and rel, support was added only for the not set option (i.e., -rel and -inv).</li>\n\t<li>Scalable functions (also called subfunctions):This feature enables the user to create, configure, and deploy a scalable functions (e.g., RDMA and networking applications) and to assign them to a container when a container is started via mlxdevm tool.A scalable function can also be deployed in an untrusted guest/host system from the NIC/DPU. This enables full configuration of the function and its representors from the NIC/DPU before giving the function for a container to run in a host system.</li>\n\t<li>Scalable function QoS and QoS group via mlxdevm&#39;s rate commands were added. Run &quot;man mlxdevm port&quot; for details.</li>\n\t<li>&quot;Signature API&quot; which, on supported devices, allows application-level data-integrity checks via a signature handover mechanism. Various signature types, including CRC32 and T10-DIF, can be automatically calculated and checked, stripped, or appended during the transfer at full wire speed.</li>\n\t<li>DR support for matching on RAW tunnel headers using the misc5 parameters, This feature allows matching on each bit of the header,</li>\n\t<li>inducing reserved fields.</li>\n</ul>\n\n<p><strong>For ConnectX-6 Dx Adapters:</strong></p>\n\n<ul>\n\t<li>Mapping a QP (Queue Pair) to AH over DEVX API, which enables DC/UD QPs to use multiple CC algorithms in the same data center.</li>\n\t<li>Better insertion rate in software steering was supported. This includes multi-QP which skips areas in the code that may be for debug only.</li>\n\t<li>Improved rate of updating steering rules, insertion, and deletion. The feature includes definers, multi-qp approach, and better memory usage.</li>\n\t<li>Added support for ability to allow or prevent insertion of duplicate rules, so the user can choose one of the following behaviors:</li>\n\t<li>Prevent duplicate rules, so that already-existing rule and fail can be detected.</li>\n\t<li>Allow duplicate rules, to enable updating the rule&#39;s action (this will only take effect once the previous rule is deleted). By default, duplicate rules are allowed.</li>\n\t<li>Made it so that all rule&#39;s insertion occur in a defined time using defined (export) size of Htble and decreased use of dynamic allocation.</li>\n</ul>\n\n<p><strong>For all HCA&#39;s:</strong></p>\n\n<ul>\n\t<li>As of version 5.4, the driver is set so that udev rules will change the names of network interfaces created from NVIDIA adapters.The udev rules are shipped to &quot;/lib/udev/rules.d&quot; and may be overridden by placing a file with the same name in &quot;/etc/udev/rules.d&quot;.</li>\n\t<li>Example: /etc/udev/rules.d/82-net-setup-link.rules</li>\n\t<li>OvS-DPDK deprecated the command &quot;ovs-appctl dpctl/dump-e2e-stats&quot;. Instead, the command has been integrated into the existing command &quot;ovs-appctl dpctl/offload-stats-show -m&quot; (when e2e-cache is enabled).</li>\n\t<li>OvS-DPDK ct-ct-nat offloads is now disabled by default.</li>\n\t<li>Before version 5.4, /etc/udev/rules.d/90-ib.rules was potentially automatically edited by installation scripts in case the options &mdash;umad-dev-rw or &mdash;umad-dev-na were used. From version 5.4 and above, those changes are made in /etc/udev/rules.d/91-ib-permissions.rules which (if exist) only include the settings for those command-line options.</li>\n\t<li>ibv_query_qp_data_in_order() API: This API enables an application to check if the given QP data is guaranteed to be in order, enabling poll for data instead of poll for completion.</li>\n\t<li>Added ethtool extended link state to mlx5e. ethtool can be used to get more information to help troubleshoot the state.</li>\n\t<li>Moved all Python scripts and some other common scripts out of the mlnxofa_ kernel packages. This removed the python dependency from that package when rebuilding it and avoided unnecessary errors when rebuilding them for custom kernels.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 5.4:</strong></p>\n\n<ul>\n\t<li>To support scalability, function representor channels were limited to 4.However in scenarios when SF (Scalable Function) was not used, certain use cases required representors to support a large number of channels.Hence, representor channel limit to 4 was applicable only when a PCI device, such as Scalable Function support, was enabled.</li>\n\t<li>Matching on ipv4_ihl (internet header length) was supported only for outer headers.&nbsp;</li>\n\t<li>When using one counter for both pop/push VLAN actions, the counter value was incorrect. Hence, Spliting the counter for pop_vlan_action_counter and push_vlan_action_counter.</li>\n\t<li>Incorrect L3 decapsulation occured when the original inner frame was small and was padded to comply with minimum frame size of 64-bytes.</li>\n\t<li>dapl and libmlx4 were needed by libdat2 and libdpdk. In order to remove or update dapl and libmlx4, their dependencies had to be removed.</li>\n\t<li>In fork situation, if parent/children processes happen to have samevirtual address, then the doorbell mechanism did not work well and may led to errors in application behavior.</li>\n\t<li>An override of log_max_qp by other devices occured if the devices share the same mlx5_core module.</li>\n\t<li>A synchronization issue where closing and opening channels (which might happen on configuration changes such as changing number of channels) may caused null pointer dereference in function mlx5e_select_queue.</li>\n\t<li>Enabling tx-udp_tnl-csum-segmentation had no affect on the driver.&nbsp;</li>\n\t<li>Old udevd versions could get stuck renaming network devices, leaving interfaces named eth* instead of enp*.&nbsp;</li>\n\t<li>Flows with t commit action with ct state -trk were not be offloaded (i.e., table=0,ct_state=-trk,ip actions=ct(commit,table=1)).</li>\n\t<li>Connection tracking over VF LAG with tunnel encapsulation/decapsulation was not supported and caused traffic drop.</li>\n\t<li>OFED compilation failed when stack size was limited to 1024.</li>\n\t<li>Setting rate/burst values higher than 2,147,483,648 were rejected.</li>\n\t<li>Offloaded remote mirroring flows on tunnel device caused forwarded traffic to VF to not be decapsulated.</li>\n\t<li>Trying to set VPort match mode on VF (cat/sys/class/net/enp8s0f2/compat/devlink/vport_match_mode), leads to kernel crash.</li>\n\t<li>OVS flows were not being offloaded over socket-direct devices.</li>\n\t<li>When VXLAN was configured and illegal route was added, the system crashed with call trace.</li>\n\t<li>If any traffic was sent before the netdev went up for the first time, a division by zero caused by a modulo operation occured in ndo_select_queue, leading to a kernel panic.</li>\n\t<li>After restarting driver, the x86 host might be in grace period and might not recover on its own. As part of the fix, 5 FW_fatal recoveries are allowed within the 20-minute grace period. As a result, the grace period in the devlink health show command will appear as 0 for FW_fatal reporter.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-MCX516A-CCH_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE 10GbE 2P SFP+ MCX4121A, HPE 10GbE 2p SFP+ MCX4621A OCP3, HPE 100GbE 2P QSFP28 MCX516A Adapter firmware on ESXi 6.7."},{"lang":"ja","x_late":"このパッケージには、ESXi 6.7上のHPE 10GbE 2P SFP+ MCX4121A、HPE 10GbE 2p SFP+ MCX4621A OCP3、HPE 100GbE 2P QSFP28 MCX516Aアダプター用のファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter (P21930-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000414</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter (P11341-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>MT_0000000238</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (P21927-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>MT_0000000417</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27166401","datemodified":"2022-02-05T13:49:34","file_list":["/CP050330.vmexe","/CP050330.vmfile","/CP050330.xml","/CP050330_VMw.zip","/payload.json","/CP050330_VMw.zip/index.xml","/CP050330_VMw.zip/vendor-index.xml","/CP050330_VMw.zip/metadata.zip","/CP050330_VMw.zip/vib20/CP050330/HPE_bootbank_CP050330_1.0.3-6.7.0.7535516.vib","/CP050330_VMw.zip/metadata.zip/vendor-index.xml","/CP050330_VMw.zip/metadata.zip/vmware.xml","/CP050330_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050330_1.0.3-6.7.0.7535516.xml","/CP050330_VMw.zip/metadata.zip/vibs/CP050330-367800446930766129.xml"],"md5sum":"50fe3e6d74a1a23a1d68704c894d26d0","name":"CP050330.zip","release":"2022-02-05T16:55:32","revision":"0","sha1sum":"3d9a7fcfae25bdde0f5f8ab40b1aa675c59606fd","size":"25MB","target_guids":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP050330","version":"1.0.3-6.7.0.7535516"}]}],"id":{"product":"e880844ad1a74e7f8866fa15b1ed3ae6","version":"a95e71e308d7410887202f1bce6382c3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline:</strong> &nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.<br />\n<br />\n<strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp;&nbsp; &nbsp;Download the appropriate SPP<br />\n&nbsp;&nbsp; &nbsp;Add the component to the SPP&nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp;&nbsp; &nbsp;Run SUM<br />\n&nbsp;&nbsp; &nbsp;Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp;&nbsp; &nbsp;For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp;&nbsp; &nbsp;Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp;&nbsp; &nbsp;Refer to the SPP documentation for detailed instructions at:www.hp.com/go/spp</p>\n\n<p style=\"margin-left:40px\"><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p><strong>To use HPE Insight Control for vCenter: </strong>&nbsp;<br />\n&nbsp;&nbsp; &nbsp;Log in to the vSphere Client &nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Click the HPE Insight Management tab&nbsp;&nbsp; &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Follow Insight Control for vCenter steps to update firmware using a Smart Component<br />\n<br />\n<strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp;&nbsp; &nbsp;Enable SSH on the ESXi host.<br />\n&nbsp;&nbsp; &nbsp;Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp;&nbsp; &nbsp;Place the Smart Component in a temporary directory<br />\n&nbsp;&nbsp;&nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp;&nbsp;&nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp;&nbsp;&nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp;&nbsp;&nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp;&nbsp; &nbsp;Logout.<br />\n&nbsp;&nbsp; &nbsp;Disable SSH on the ESXi host.<br />\n&nbsp;&nbsp; &nbsp;Reboot your system, if required, for the firmware update to take effect.</p>\n"},{"lang":"ja","x_late":"<p><strong>オフライン：</strong>    <br />\n    SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます。<br />\n<br />\n<strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合:</strong><br />\n    適切なSPPをダウンロードします<br />\n    SPPにコンポーネントを追加します    <br />\n    更新対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします<br />\n    SUMを実行します<br />\n    リモートターゲット/ノードとして更新対象のESXiホストを追加します  <br />\n    更新対象のESXiホストのIPまたはDNSアドレスを入力します  <br />\n    ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します  <br />\n    SUM 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。<br />\n    ファームウェアのアップデートを完了するために、Smart Update Managerの指示に従います<br />\n    詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください: http://www.hpe.com/go/spp</p>\n\n<p style=\"margin-left:40px\"><strong>注記：</strong>SUMを使用してファームウェアをアップデートしている間に、レビューページの\"View Devices\"オプションが、アダプター名のリストにありません。これは予測される動作で、コンポーネントの機能に影響を与えません。</p>\n\n<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください:</strong> <br />\n    vSphereクライアントにログインします     <br />\n    インベントリツリーのサーバーまたはクラスターを選択します  <br />\n    HPE Insight Managementタブをクリックします    <br />\n    Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います<br />\n<br />\n<strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。 </strong><br />\n    ESXiホストでSSHを有効にします。<br />\n    rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）  <br />\n    Smartコンポーネントを一時ディレクトリに置きます<br />\n    nmstモジュールがすでにロードされているかどうかチェックします: vmkload_mod -l | grep nmst<br />\n    モジュールがロードされていない場合、次のコマンドを使用してモジュールをロードします: vmkload_mod nmst<br />\n    同じディレクトリからSmartコンポーネントを実行します。例：unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n    Smartコンポーネントの指示に従います。<br />\n    ログアウトします。<br />\n    ESXiホストでSSHを無効にします。<br />\n    必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for Mellanox Open Ethernet cards"},{"lang":"ja","x_late":"Mellanox Open Ethernetカードのオンラインファームウェアアップグレードユーティリティ（ESXi 6.7）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T07:18:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1014:</strong></p>\n\n<p>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 14.31.1200:</strong></p>\n\n<p>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</p>\n\n<p><strong>Firmware for the following devices is&nbsp;updated to 16.31.1014:</strong></p>\n\n<p>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</p>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). Note: If the port does not go up, switch to Force mode.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t<li>&nbsp; &nbsp; &nbsp; &nbsp; Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P21930-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCAT Adapter)</li>\n\t<li>P11341-B21 (HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following device&nbsp;has been updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>P21927-B21 (HPE Ethernet 100Gb 2-Port QSFP28 MCX516A-CCHT Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11400032","languages":[{"lang":"tw","x_late":"應用程式 - 系統管理"},{"lang":"en","x_late":"Application - System Management"},{"lang":"ko","x_late":"응용 프로그램 - 시스템 관리"},{"lang":"ja","x_late":"アプリケーション - システム マネジメント"},{"lang":"cn","x_late":"应用程序 - 系统管理"}]}],"description":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 6.5"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[],"files":[{"bytes":"4417066","datemodified":"2022-02-08T13:13:49","file_list":["/cp049605.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/index.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vendor-index.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/sut-6.5.0.2.9.1.0-16.vib","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/sutesxcli-6.5.0.2.9.1.0-8.vib","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/ilo_650.10.7.5.2-1OEM.650.0.0.4240417.vib","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vendor-index.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vmware.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vibs/sut--6408725623188735120.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vibs/sutesxcli-1371252517080177184.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vibs/ilo-5995240362405261046.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/vibs/cru-6087260586819000143.xml","/sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/metadata-sut-esxi6.5-offline-bundle-2.9.1.0-8.zip/bulletins/sut-esxi6.5-offline-bundle-2.9.1.0-8.xml"],"md5sum":"15cc71599d7b280f409d66cd6707bb97","name":"cp049605.zip","release":"2022-02-08T13:11:32","revision":"0","sha1sum":"073344f1bc61c1a7ffd4c319a7b62aed07e5321a","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ece09b5689","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecf680a7e2"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"sut","version":"6.5.0.2.9.1.0-16"},{"name":"sutesxcli","version":"6.5.0.2.9.1.0-8"},{"name":"ilo","version":"650.10.7.5.2-1OEM.650.0.0.4240417"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"}]}],"id":{"product":"35aedb12078f4cf798d76b05b4d2ddf4","version":"5ac7b3c11ea3442f8d5934071452a92b"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Installing VIBs on the ESXi 6.5 host from the ESXi shell:</strong></p>\n\n<ul>\n\t<li>Transfer the VIB(s) onto the ESXi host local path</li>\n\t<li>Run the following esxcli command on the ESXi shell to install the VIB(s):</li>\n</ul>\n\n<p><strong>~# esxcli software vib install -v &lt;path&gt;&lt;filename.vib&gt;</strong></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Integrated Smart Update Tools 2.9.1 for ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-21T09:41:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","latest_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n"},{"curr_enhancements_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","curr_fixes_x_late":"<p>See the&nbsp;<a href=\"http://www.hpe.com/info/sut-docs\">iSUT Release Notes&nbsp;</a>for information about the issues resolved in this release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"","value":"HP Smart Update Tools (HP SUT)"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"sut:6.5.0.2.9.1.0-16","sw_key_expectedpath":"software:vmware:zip"},{"name":"ilo:650.10.7.5.2-1OEM.650.0.0.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"sutesxcli:6.5.0.2.9.1.0-8","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800100","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置"},{"lang":"en","x_late":"Software - Storage"},{"lang":"ko","x_late":"소프트웨어 - 스토리지"},{"lang":"ja","x_late":"ソフトウェア - ストレージ"},{"lang":"cn","x_late":"软件 - 存储"}]}],"description":[{"lang":"en","x_late":"The Host Explorer communicates with the HPE 3PAR StoreServ system over an FC or iSCSI connection and enables the host to send detailed host configuration information to the HPE 3PAR StoreServ System. The information gathered from the Host Explorer is visible for uncreated hosts and assists with host creation and diagnosing host connectivity issues. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1682304","datemodified":"2018-02-09T04:43:11","file_list":["cp034831.xml","cpqsetup.exe","hesetup.exe","HostExplorer-win2k12-3.2.1-0.x64.msi","HostExplorer-win2k16-3.2.1-0.x64.msi","HostExplorer-windows-3.2.1-0.x64.msi"],"md5sum":"6eaa3327221828d012b3872f674a5886","name":"cp034831.exe","release":"2018-02-09T04:08:03","revision":"0","sha1sum":"2129fd8429cb944a74b72b0d43e0f8c58b9db057","size":"1MB","target_guids":[],"type_of_change":"1","version":"3.2.1.0"}],"id":{"product":"d2758fac106e4fcd86a4e9b65fdf0119","version":"7c9e3001602d47ada84aad1f7ba11fd2"},"installation":{"command":"hesetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the smart component&nbsp;to host machine and run the smart component.</p>\n\n<p>HPE 3PAR HostExplorer smart component will be installed only if the host has connectivity&nbsp;to HPE&nbsp;3PAR StoreServ.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE 3PAR HostExplorer for Windows Server 2008 2012 and 2016 x64 Operating Systems"},{"lang":"ja","x_late":"Windows Server 2008 2012および2016 x64オペレーティング システム用のHPE 3PAR HostExplorer"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"1","name":"Microsoft Windows Server 2008 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64","platform":"nt_x86-64","sr":"OEM"},{"edition":"srvr","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"core","major":"6","minor":"0","name":"Microsoft Windows Server 2008 x64 - Server Core Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"ebs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Essential Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"fndtn","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Foundation Edition","platform":"nt_x86-64","sr":"OEM"},{"edition":"sbs","major":"6","minor":"0","name":"Microsoft Windows Server 2008 Small Business","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-03-07T06:35:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>&nbsp;Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>&nbsp;Support for Windows server 2016</li>\n</ul>\n","latest_fixes_x_late":"<p>The following issues are&nbsp;fixed for HPE 3PAR Host Explorer 3.2.0 release:&nbsp;</p>\n\n<ul>\n\t<li>&nbsp;IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Following are the new enhancements added in this release:</p>\n\n<ul>\n\t<li>Tokens for detecting if the host is T10 DIF capable .</li>\n\t<li>&nbsp;Tokens for getting the&nbsp; Host Consumed Capacity, mount points and File System allocation units&nbsp;</li>\n\t<li>&nbsp;Token added for checking if a server is booting from SAN</li>\n\t<li>Support for Windows server 2016</li>\n\t<li>HPE 3PAR Host Explorer Windows supports upgrade to 3.2.1.</li>\n\t<li>HPE 3PAR OS version compatibility check in HPE 3PAR Host Explorer</li>\n</ul>\n","curr_fixes_x_late":"<p>The following are the issues fixed in HPE 3PAR Host Explorer 3.2.1 release:</p>\n\n<ul>\n\t<li>IP address token can take multiple IPs of the host with comma seperated values.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8-GHz 16GB Control/32GB Data Cache Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rack Configuration Base"},{"key":"","value":"HP 3PAR StoreServ 10400 32GB Control/64GB Data Cache Rackmount Config Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10400 2.8GHz 32GB Control/64GB Data Cache Upgr Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7450 4-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 10800 2.8-GHz 32GB Control/64GB Data Cache Controller Node"},{"key":"","value":"HP 3PAR StoreServ 10800 3PAR 2.8-GHz 32GB Control/64GB Data Upg Controller Node"},{"key":"","value":"HP 3PAR StoreServ 7450 2-node Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7400c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7200c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 4-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7440c 2-node Storage Base for Storage Centric Rack"},{"key":"","value":"HP 3PAR StoreServ 7450c 4-node Field Integrated Storage Base"},{"key":"","value":"HP 3PAR StoreServ 7200 2-node Storage Base for Storage Centric Rack"}],"sw_keys":[{"name":"TpdHostAgent.exe","sw_key_expectedpath":"%PROGRAMFILES%\\Host Explorer"},{"name":"3PAR Host Explorer","sw_key_expectedpath":"software:sd:3parhostexplorer"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp;</strong> &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5977558","datemodified":"2021-08-16T12:05:33","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/CP049286.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/TACM6ALLGPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049286.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049286.scexe"],"md5sum":"2410587991c6dc11a56f0381007dde83","name":"firmware-hdd-3815d4b024-GPK3-2.1.x86_64.rpm","release":"2021-08-16T11:53:06","revision":"0","sha1sum":"8674febaf3f4895c9b1c253d00f41a5ca399e41a","size":"5MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"990fcc25e986467fbdc6e3aae2e41a2c","version":"fd7335e522f94f0aa6eedd8727c0a8b3"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:38:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5967239","datemodified":"2021-07-23T10:38:35","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/CP049053.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/SHPEEVANSSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049053.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049053.scexe"],"md5sum":"556eeb06ce3a2fa391fbe518fc43f4d1","name":"firmware-hdd-cf0b6cabe1-HPD2-2.1.x86_64.rpm","release":"2021-07-23T10:23:06","revision":"0","sha1sum":"8367f279ba1a15753cd193f5309e621b2612a1f6","size":"5MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"fa3afb08b69b4eb3ac32d9088c68d3a9","version":"23a30a4309a446afa2a21be95349bbd9"},"installation":{"command":"CP040294.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:35:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB, and EG1200JEMDA"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"17499607","datemodified":"2021-08-30T05:23:57","file_list":["/CP048263_BUILD_6.data","/CP048263.vmexe","/CP048263.vmexe64","/CP048263.vmfile","/CP048263_VMw.zip","/CP048263.xml","/payload.json","/CP048263_VMw.zip/index.xml","/CP048263_VMw.zip/vendor-index.xml","/CP048263_VMw.zip/metadata.zip","/CP048263_VMw.zip/vib20/CP048263/HPE_bootbank_CP048263_HPD6.6-7.0.0.15843807.vib","/CP048263_VMw.zip/metadata.zip/vendor-index.xml","/CP048263_VMw.zip/metadata.zip/vmware.xml","/CP048263_VMw.zip/metadata.zip/vibs/CP048263-3930429380519207185.xml","/CP048263_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048263_HPD6.6-7.0.0.15843807.xml"],"md5sum":"4e3fad9e60a56757fd27b304161773a8","name":"CP048263.zip","release":"2021-08-30T05:19:33","revision":"0","sha1sum":"2e55bd3df918d2f1bcc078e0320ed8a9eadd1775","size":"16MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048263","version":"HPD6.6-7.0.0.15843807"}]}],"id":{"product":"f47f99ce0a3d4f73a3af884b56c63c54","version":"f7b3de47009f436e824f98a1f43b61d1"},"installation":{"command":"CP042546.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T10:27:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."},{"lang":"ja","x_late":"Agentless Management Service（AMSD）は、Integrated Lights Out 5（iLO 5）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"3026379","datemodified":"2021-12-06T05:21:28","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/04","./usr/lib/.build-id/04/d80a08306fd391899adf6287072c9489e48586","./usr/lib/.build-id/04/d80a08306fd391899adf6287072c9489e48586.1","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/c376d56e56652462fdb5a4e3c8b2e370fa5735","./usr/lib/.build-id/53","./usr/lib/.build-id/53/d265e5ecc6fe3141f39649329b0e929c1422af","./usr/lib/.build-id/53/d265e5ecc6fe3141f39649329b0e929c1422af.1","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dfff988f647ec9d1e66e932c411290290ceed2","./usr/lib/.build-id/58/dfff988f647ec9d1e66e932c411290290ceed2.1","./usr/lib/.build-id/6b","./usr/lib/.build-id/6b/4cfaca1042d061b3a18648d5eeffe543479424","./usr/lib/.build-id/6b/4cfaca1042d061b3a18648d5eeffe543479424.1","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/d4363b28030d1fa437f1b06018644dd94f728e","./usr/lib/.build-id/6c/d4363b28030d1fa437f1b06018644dd94f728e.1","./usr/lib/.build-id/92","./usr/lib/.build-id/92/2d665f5388cb7029c1c57ef0ba803f3b657b46","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/fcfb979ed3600ab7ad5007d7dd6af642986f43","./usr/lib/.build-id/f8/fcfb979ed3600ab7ad5007d7dd6af642986f43.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"05075363db58f6af912080a6354db302","name":"amsd-2.6.0-1701.1.rhel8.x86_64.rpm","release":"2021-12-06T05:09:21","revision":"0","sha1sum":"19c9821d392001272c63a88c459a5ba6a50d40be","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"2.6.0"}],"id":{"product":"c8581e07bdde4d5584c0276be971751e","version":"79ab87bfd4b74c079e1e2f74ce2b24dd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<ul>\n\t<li>パッケージをインストールするには、次のようにタイプします。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-<version>.rpm</li>\n\t</ul>\n\t</li>\n\t<li>パッケージが正しくロードされているか、以下をタイプして確認します。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>以下のコマンドを実行してヘルプを参照してください。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T14:26:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>New support added to amsd:</p>\n\n<ul>\n\t<li>Enhance the direct-attached SATA Drive Status - smart Error&nbsp;and failed.</li>\n\t<li>Enhance the direct-attached SATA Drive Status under hot-plug and hot-remove.</li>\n\t<li>Provide the new OID, cpqIdeAtaDiskCapacityLowBytes and cpqIdeAtaDiskCapacityHighBytes for SATA HD capacity support:</li>\n\t<li>HPE Synergy 4610C 10/25Gb Ethernet Adapter.</li>\n\t<li>HPE FC HBA/SN1700E</li>\n\t<li>HPE DSP DSC-25/100 Ent/Cld 10/25/100Gb</li>\n\t<li>Support for Red Hat Enterprise Linux 8.4</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for HPE Intel Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Intel NICs Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3654102","datemodified":"2021-11-05T03:12:14","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-igb","./lib/modules/5.3.18-22-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"561cfc3dae2b03f367db318f1061faca","name":"hp-igb-kmp-default-6.8.5_k5.3.18_22-2.sles15sp2.x86_64.rpm","release":"2021-11-05T03:02:58","revision":"0","sha1sum":"40c56883c2ff4502b8f41a4758c0411d56e1baa3","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"1","version":"6.8.5-2"},{"bytes":"3766505","datemodified":"2021-11-05T03:15:13","file_list":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/hp-igb","./lib/modules/5.3.18-57-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"md5sum":"6cfa20b2ad2d1e9c94d7224059110a60","name":"hp-igb-kmp-default-6.8.5_k5.3.18_57-2.sles15sp3.x86_64.rpm","release":"2021-11-05T03:02:58","revision":"0","sha1sum":"a7c2eb1a01bb99d68e2734d0fe7fd3abca2cbaba","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"type_of_change":"1","version":"6.8.5-2"}],"id":{"product":"a162b7594d8d4a02bf2f3f7d9fe2609d","version":"0844aa78e7424fc7b293aa4dce807bd8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Intel igbドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-05T01:47:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Linux Firmware upgrade utility v.1.22.5</li>\n\t<li>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-igb-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001000KWJSE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3030-304b574a5345","Version":"4ICDHPK1"},{"DeviceName":"VO002000KWJSF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3230-3030-304b574a5346","Version":"4ICDHPK1"},{"DeviceName":"VO004000KWJSH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3430-3030-304b574a5348","Version":"4ICDHPK1"},{"DeviceName":"VT004000KWJSU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-3054-3430-3030-304b574a5355","Version":"4ICDHPK1"},{"DeviceName":"MO001600KWJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b574a534e","Version":"4ICDHPK1"},{"DeviceName":"MO003200KWJSQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4ICDHPK1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b574a5351","Version":"4ICDHPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ Drives</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Known Issues:</strong>&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4951010","datemodified":"2021-07-25T12:33:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/4ICDHPK1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/CP048506.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1656c1b14a-4ICDHPK1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048506.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048506.scexe"],"md5sum":"cf0fe46c261c0dd9272e9a5b4554ba29","name":"firmware-hdd-1656c1b14a-4ICDHPK1-2.1.x86_64.rpm","release":"2021-07-25T12:22:04","revision":"0","sha1sum":"e31a475ab5ea40f7992910b07b7bef6b379c9e60","size":"4MB","target_guids":["562340a5-304f-3130-3030-304b574a5345","562340a5-304f-3230-3030-304b574a5346","562340a5-304f-3430-3030-304b574a5348","562340a5-3054-3430-3030-304b574a5355","4d2340a5-304f-3130-3630-304b574a534e","4d2340a5-304f-3330-3230-304b574a5351"],"type_of_change":"2","version":"4ICDHPK1"}],"id":{"product":"288dbea3acd4439082f94ee3a892bf62","version":"23c38495249f4006bf966b835978b389"},"installation":{"command":"CP043037.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong>追加情報:</strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001000KWJSE, VO002000KWJSF, VO004000KWJSH, VT004000KWJSU, MO001600KWJSN and MO003200KWJSQ  Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001000KWJSE、VO002000KWJSF、VO004000KWJSH、VT004000KWJSU、MO001600KWJSN、およびMO003200KWJSQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWJSQ","target_guid":"4d2340a5-304f-3330-3230-304b574a5351","type":"nvme"},{"id":"VO002000KWJSF","target_guid":"562340a5-304f-3230-3030-304b574a5346","type":"nvme"},{"id":"MO001600KWJSN","target_guid":"4d2340a5-304f-3130-3630-304b574a534e","type":"nvme"},{"id":"VO001000KWJSE","target_guid":"562340a5-304f-3130-3030-304b574a5345","type":"nvme"},{"id":"VT004000KWJSU","target_guid":"562340a5-3054-3430-3030-304b574a5355","type":"nvme"},{"id":"VO004000KWJSH","target_guid":"562340a5-304f-3430-3030-304b574a5348","type":"nvme"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T05:55:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware corrects the potential for a drive to become disabled and nonfunctional during certain conditions or workloads.</li>\n\t<li>After the drive is upgraded to firmware version HPK1, it cannot be downgraded to firmware version HPK0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO001000KWJSE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO002000KWJSF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWJSN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO004000KWJSH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWJSQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VT004000KWJSU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントおよびファームウェアは、以下のような場合に使用してください。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPE Service Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"34466461","datemodified":"2021-01-28T15:10:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/CP046216.xml","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/archives/hpoa350.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oa497.bin","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade32","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/oaupgrade64","./usr/lib/x86_64-linux-gnu/firmware-oa-4.97-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046216.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046216.scexe"],"md5sum":"7e9e77475f20a1849957d8e789fd5135","name":"firmware-oa-4.97-1.1.x86_64.rpm","release":"2021-01-28T14:59:07","revision":"0","sha1sum":"faa394574186f2d488dd1b78b4caf4174486511d","size":"32MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"C9506","version":"71201b28c2ee415cb2442224c541abea"},"installation":{"command":"oaupgrade","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a standalone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on HPE Service Pack for ProLiant (SPP), the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a standalone component</strong></p>\n\n<p>This SCEXE component is a self-extracting executable. The SCEXE file unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.<br />\n<br />\nThe general command line syntax for this smart component is</p>\n\n<p>sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</p>\n\n<p>where cpxxxxxx.scexe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul>\n\t<li>-target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The netAddress parameter is the IP address or DNS name of the OA to target. This should be the Active OA if two OA&rsquo;s are in an enclosure. There is a space between the -target and the netAddress parameter.</li>\n\t<li>-user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The username is the userid to use when attempting to login to the OA. There is a space between the -user and the username parameter.</li>\n\t<li>-passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA. There is a space between the -passwd and the password parameter.</li>\n\t<li>-s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The silent option will silently install the firmware, if needed.</li>\n\t<li>-f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>-logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp; &nbsp;&nbsp;&nbsp;This optional parameter is used to redirect the output from the OA flash utility to a different directory than the default location of /var/hp/log/&lt;netAddress&gt;. The redirected location is &lt;path&gt;/hp/log/&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>Download the SCEXE file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>Execute sh cpxxxxxx.scexe -target &lt;netAddress&gt; -user &lt;username&gt; -passwd &lt;password&gt; [-s[ilent]] [-f[orce]] [-logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are:</p>\n\n<ul>\n\t<li>0 Success</li>\n\t<li>1 Reserved</li>\n\t<li>2 Upgrade is not needed because firmware version is current</li>\n\t<li>3 Upgrade is not needed because newer firmware version is present</li>\n\t<li>4 Target not found</li>\n\t<li>5 User terminated session</li>\n\t<li>6 Incorrect parameter</li>\n\t<li>7 General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、HP Service Pack for ProLiant（SPP）上のHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSCEXEコンポーネントは、自己解凍型実行可能ファイルです。SCEXEファイルは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。<br />\n<br />\nこのSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p>sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</p>\n\n<p>cpxxxxxx.scexeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul>\n\t<li>-target <netAddress>          netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。-targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li>-user <username>              ユーザー名はOAにログインするときに使用するユーザーIDです。-userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li>-passwd <password>           パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。-passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li>-s[ilent]                               サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li>-f[orce]                               forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li>-logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所/var/hp/log/<netAddress>ではなく、別のディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>/hp/log/<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li>アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSCEXEファイルをダウンロードします。</li>\n\t<li>Execute sh cpxxxxxx.scexe -target <netAddress> -user <username> -passwd <password> [-s[ilent]] [-f[orce]] [-logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li>0 成功</li>\n\t<li>1 予約済み</li>\n\t<li>2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li>3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li>4  ターゲットが見つからない</li>\n\t<li>5 ユーザーによって中止された</li>\n\t<li>6 パラメーターが不正</li>\n\t<li>7 通常の障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Linux"},{"lang":"ko","x_late":"Linux용 온라인 HPE 블레이드 시스템 c-클래스 Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Linux 的联机 HPE BladeSystem c 类板载管理员固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Linux"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages..</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name (CN) field and IP address in <strong>SAN </strong>field.</strong></li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:40px; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:40px; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p style=\"text-align:justify\">&nbsp;</p>\n\n<p style=\"margin-left:40px; text-align:justify\">&nbsp;The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on OA version 4.90 and less than 4.90. This issue is caused by the introduction of new &nbsp;signature in the iLO5 firmware version 2.10</p>\n\n<p style=\"margin-left:40px; text-align:justify\">. The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含的套件 QLogic 光纖通道主機匯流排配接卡的 Windows 64 位元作業系統上提供對 Smart SAN 的支援。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic fibre channel host bus adapters on Windows 64 bit operating systems."},{"lang":"ko","x_late":"이 패키지에는 Windows 64 비트 운영 체제에서 QLogic 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Windows 64 位操作系统上的 QLogic 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、Windows 64ビット オペレーティングシステムでQLogic ファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1570136","datemodified":"2021-08-27T04:07:30","file_list":["cp042521.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"md5sum":"1e2ee82830b742a27f83ecc22812673b","name":"cp042521.exe","release":"2021-08-27T04:02:22","revision":"0","sha1sum":"484d6b1ece69f9213a52c4b07cf3b4339525ca87","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"7eb6e3adc2094748b6a18ae2e5daf1e0","version":"3888d419ab9447b2b4accd602efbfe96"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp;It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp;If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp;No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2016/2019 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-12-28T08:11:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLSMARTSANVer.exe","sw_key_expectedpath":"%SystemDrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000GEFNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304745464e41","Version":"HPG6"},{"DeviceName":"MB6000GEFNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRATG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745464e42","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB4000GEFNA and MB6000GEFNB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - &nbsp;MB4000GEFNA and MB6000GEFNB Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features for :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3444752","datemodified":"2021-07-25T14:40:19","file_list":["cp048592.xml","cpqsetup.exe","payload.json","setup.dll","SMKRATG6.rel"],"md5sum":"7303da84807e3550fbb94fd24ec37ddb","name":"cp048592.exe","release":"2021-07-25T14:33:04","revision":"0","sha1sum":"7c813f8a5ac17216a9dbc0db5f589e5d090c9ad9","size":"3MB","target_guids":["002340a5-4d00-3442-3030-304745464e41","002340a5-4d00-3642-3030-304745464e42"],"type_of_change":"1","version":"HPG6"}],"id":{"product":"edc1764ca6d04bbd943cd314f29904b6","version":"6cc6c91541e3402a8b9fbf189335f9f6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB4000GEFNA and MB6000GEFNB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB4000GEFNAおよびMB6000GEFNBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB4000GEFNA","target_guid":"002340a5-4d00-3442-3030-304745464e41","type":"sata"},{"id":"MB6000GEFNB","target_guid":"002340a5-4d00-3642-3030-304745464e42","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:10:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GEFNA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB6000GEFNB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2032406","datemodified":"2021-11-02T23:37:37","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"eb68822c9ea3d5767e0cc57cf7a0d07c","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.sles15sp3.x86_64.rpm","release":"2021-11-02T22:18:08","revision":"0","sha1sum":"2b3ee070788b474baf61ab2b6b4349d0f63f5a98","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"1984582","datemodified":"2021-11-02T23:42:12","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/compat","./lib/modules/5.3.18-57-default/updates/compat/mlx_compat.ko","./lib/modules/5.3.18-57-default/updates/drivers","./lib/modules/5.3.18-57-default/updates/drivers/infiniband","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/5.3.18-57-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.3.18-57-default/updates/drivers/net","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.3.18-57-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host","./lib/modules/5.3.18-57-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target","./lib/modules/5.3.18-57-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.3.18-57-default/updates/net","./lib/modules/5.3.18-57-default/updates/net/9p","./lib/modules/5.3.18-57-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/rds","./lib/modules/5.3.18-57-default/updates/net/rds/rds_rdma.ko","./lib/modules/5.3.18-57-default/updates/net/smc","./lib/modules/5.3.18-57-default/updates/net/smc/smc.ko","./lib/modules/5.3.18-57-default/updates/net/smc/smc_diag.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.3.18-57-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"14f044dcf59b29592768d30ed75e065a","name":"mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_57-OFED.4.9.4.0.8.1.sles15sp3.x86_64.rpm","release":"2021-11-02T22:18:08","revision":"0","sha1sum":"109b7197d993328990d3252dad7dc13f063cf138","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"d1be4f718af247a2a4c1efaa6c20721f","version":"cad925becf9740c786332c702fb40418"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9.&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using &nbsp;5.3.18-53-default&nbsp;kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles15sp3.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k5.3.18_53-OFED.4.9.3.1.6.1.sles15sp3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 15 SP3 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050868.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.601"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3351200","datemodified":"2022-01-26T03:53:52","file_list":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/CP050870.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/cp050868.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/cp050868.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.04.601-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050870.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050870.scexe"],"md5sum":"37856e36a7ef746aaf0b12a50ab71d31","name":"firmware-spsgen10-04.01.04.601-1.1.x86_64.rpm","release":"2022-01-26T03:46:55","revision":"0","sha1sum":"4152f52fbf7797b5cc554b8603055f4bfe47ddf9","size":"3MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.04.601"}],"id":{"product":"84d998355c4f4bc6997437e9a6c61fba","version":"196d161db9dc4f8c85bd5460ca890cb5"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">HP USB Key Utility</a></strong>を使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - Server Platform Services(SPS)ファームウェアfor HPE Gen10サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T03:42:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware addresses an issue where not all PCIe devices will be managed properly by the system when there are more than 16 PCIe devices present in the platform. This would include PCIe devices in PCIe slots or NVMe drives. This issue would typically manifest itself as iLO Firmware not properly reporting thermals from a device when a server was in this heavily loaded configuration.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2021.2 guidance.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB014000GWRTN, MB012000GWRTL and MB010000GWRTK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n"}],"files":[{"bytes":"5890717","datemodified":"2021-07-23T07:19:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/CP048141.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048141.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048141.scexe"],"md5sum":"f8fdcf8446cf8a3c9b09a388c8ceafac","name":"firmware-hdd-6b7ce3da0e-HPG2-6.1.x86_64.rpm","release":"2021-07-23T07:07:16","revision":"0","sha1sum":"f0f800770a6ed472419692fafde05f6abb7331bd","size":"5MB","target_guids":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"05a81ac262384916b1fa6e922a6cada6","version":"253a28257fe94279b7de4b1a64765488"},"installation":{"command":"CP041455.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB014000GWRTN、MB012000GWRTLおよびMB010000GWRTKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWRTN","target_guid":"4d2340a5-3042-3431-3030-30475752544e","type":"sata"},{"id":"MB012000GWRTL","target_guid":"4d2340a5-3042-3231-3030-30475752544c","type":"sata"},{"id":"MB010000GWRTK","target_guid":"4d2340a5-3042-3031-3030-30475752544b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:11:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWRTK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWRTN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB012000GWRTL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel i40en Adapters running under VMware vSphere 7.0"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.13.1.0.</p>\n"}],"files":[{"bytes":"239658","datemodified":"2021-11-03T07:41:46","file_list":["/cp045338.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/index.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/vendor-index.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/metadata.zip","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/vib20/i40en/INT_bootbank_i40en_2.1.5.0-1OEM.700.1.0.15843807.vib","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/metadata.zip/vmware.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/metadata.zip/vibs/i40en-5271580034840737875.xml","/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807_18631754.zip/metadata.zip/bulletins/Intel-i40en_2.1.5.0-1OEM.700.1.0.15843807.xml"],"md5sum":"ec9a12a6a5b69c9c536e5e182a9b7868","name":"cp045338.zip","release":"2021-11-03T07:37:25","revision":"0","sha1sum":"e62dac097902bc0105b1af5cea9d491efafd2e95","size":"234KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","20a6e8e4-bf33-4c71-a6bf-d9ec09108524"],"type_of_change":"1","version":"2021.12.00","vib_list":[{"name":"i40en","version":"2.1.5.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"d892124a7e30440eb7f95535da6dada7","version":"29d0333d0ce542c894c03206fb156445"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel i40en Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product supports the following new server:</p>\n\n<ul>\n\t<li>HPE ProLiant DL20 Gen10 Plus Server</li>\n\t<li>HPE ProLiant ML30 Gen10 Plus Server&nbsp;<br />\n\t&nbsp;</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product corrects an issue where PSOD when drivers loading.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"i40en:2.1.5.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-i40en:2.1.5.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GFEMH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304746454d48","Version":"HPG6"},{"DeviceName":"MB4000GFEMK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPNFG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304746454d4b","Version":"HPG6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GFEMH and MB4000GFEMK"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB2000GFEMHおよびMB4000GFEMK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp; This issue was found during supplier ongoing reliability testing.</p>\n\t</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3660160","datemodified":"2021-07-25T14:04:00","file_list":["cp048588.xml","cpqsetup.exe","HAKPNFG6.rel","payload.json","setup.dll"],"md5sum":"a89493b73c853209ba764a9908d2d4f0","name":"cp048588.exe","release":"2021-07-25T13:56:05","revision":"0","sha1sum":"a357b9d87bba7b672e8546b7b6d9edc526073879","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304746454d48","002340a5-4d00-3442-3030-304746454d4b"],"type_of_change":"2","version":"HPG6"}],"id":{"product":"c3a161d21e2947f3af496f6cde08c95f","version":"264e0011088b4cf19fed0b8bfb7147f0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GFEMH and MB4000GFEMK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB2000GFEMHおよびMB4000GFEMKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000GFEMH","target_guid":"002340a5-4d00-3242-3030-304746454d48","type":"sata"},{"id":"MB4000GFEMK","target_guid":"002340a5-4d00-3442-3030-304746454d4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:16:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.Â  This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Corrects a potential data integrity issue caused by an in process write retry incorrectly starting at the wrong location.&nbsp;This issue was found during supplier ongoing reliability testing.</li>\n\t<li>\n\t<p>The firmware also corrects settings preservation after a code download, and includes emergency power off improvements.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GFEMK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GFEMH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the RoCE (RDMA over Converged Ethernet) library for supported HPE Broadcom NetXtreme-E adapter cards running under Red Hat Enterprise Linux 8 Update 3."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"25226","datemodified":"2021-02-11T00:34:01","file_list":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/28b8217315bea3e5ba8b5181d0344ffc78222b","./usr/lib64/libbnxt_re-218.0.7.0.so","./usr/lib64/libbnxt_re-rdmav25.so","./usr/lib64/libbnxt_re.so","./usr/share/smartupdate/libbnxt_re/component.xml"],"md5sum":"c13b8766d07e511ce475f4cad413d239","name":"libbnxt_re-218.0.7.0-rhel8u3.x86_64.rpm","release":"2021-02-11T00:31:30","revision":"0","sha1sum":"6201a9c882b41da5d1801be4dd7bb59f7d39991f","size":"24KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"type_of_change":"0","version":"218.0.7.0"}],"id":{"product":"b6f6f77678514383bdf949306b683bf3","version":"8acb3a0ef8c64bbb9919ed6dd31cf314"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"text-align:left\">rpm -ivh &lt;bnxt_rooce &gt;.rpm --force [--replacefiles]</p>\n\n<p style=\"text-align:left\">Use --force or --replacefiles options while installing or updating the HPE Broadcom RoCE library which may conflict with inbox library</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 8 Update 3."}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c3","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159002c5","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c3","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c5159002c5","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c3","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159002c5","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c3","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16dc159016d7","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020c","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c515900211","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c51590020e","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d8","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"16D7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16c1159016d7","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020c","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd15900211","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16bd1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px\">Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"libbnxt_re","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4443565","datemodified":"2021-08-26T08:59:41","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.3.18-57-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"e0aa766376827492940bd9dc87010a6b","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_57-4.sles15sp3.x86_64.rpm","release":"2021-08-26T08:49:03","revision":"0","sha1sum":"be87207977b427de743e95e4764de140cb554137","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"eb66fafd28ff4c39a42b91395104bd05","version":"ed345e091cc6478383fa196dd910002c"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k5.3.18_53-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 3 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Improve detection and recovery from conditions described in customer advisory available at <a href=\"http://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Blade Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.9.12.0.</p>\n"}],"files":[{"bytes":"197137","datemodified":"2021-08-12T03:50:43","file_list":["/cp045169.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/vib20/ixgben/INT_bootbank_ixgben_1.9.12.0-1OEM.700.1.0.15843807.vib","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/vibs/ixgben--3083509160048418717.xml","/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807_17899222.zip/metadata.zip/bulletins/Intel-ixgben_1.9.12.0-1OEM.700.1.0.15843807.xml"],"md5sum":"4f4e04096a6d9b942d91406ca8d2115b","name":"cp045169.zip","release":"2021-08-12T03:47:29","revision":"0","sha1sum":"27ac073f3ee05428d8be2067d321889a0cc4a03b","size":"192KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c","20a6e8e4-bf33-4c71-a6bf-d9ec6164afab"],"type_of_change":"0","version":"2021.09.01","vib_list":[{"name":"ixgben","version":"1.9.12.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"026326f2a6e64525ac6b82dd92bae1e8","version":"790a817c7f1643cfaccf55a7a5505a7d"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 U3.</p>\n","curr_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.<br />\nThis product addresses issues with hardware VLAN offloading.<br />\nThis product addresses a TX hang during bi-directional traffic.<br />\nThis product addesses issues with NetQ RSS and VMDQ scenarios.<br />\nThis product addesses issues with MTU settings when SRIOV is enabled in DPDK environment<br />\nThis product addessses issues with several VF scenarios without PF interface.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ixgben:1.9.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Intel-ixgben:1.9.12.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWVNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57564e42","Version":"HPK3"},{"DeviceName":"MO003200KWVNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57564e43","Version":"HPK3"},{"DeviceName":"MO006400KWVND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57564e44","Version":"HPK3"},{"DeviceName":"MT001600KWSTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57535442","Version":"HPK3"},{"DeviceName":"MT003200KWSTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57535443","Version":"HPK3"},{"DeviceName":"MT006400KWSTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725b0HPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57535444","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20960508","datemodified":"2021-08-26T11:49:50","file_list":["/CP048478_BUILD_4.data","/CP048478.vmexe","/CP048478.vmexe64","/CP048478.vmfile","/CP048478_VMw.zip","/CP048478.xml","/payload.json","/CP048478_VMw.zip/index.xml","/CP048478_VMw.zip/vendor-index.xml","/CP048478_VMw.zip/metadata.zip","/CP048478_VMw.zip/vib20/CP048478/HPE_bootbank_CP048478_HPK3.4-7.0.0.15843807.vib","/CP048478_VMw.zip/metadata.zip/vendor-index.xml","/CP048478_VMw.zip/metadata.zip/vmware.xml","/CP048478_VMw.zip/metadata.zip/vibs/CP048478-2379620384603753753.xml","/CP048478_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048478_HPK3.4-7.0.0.15843807.xml"],"md5sum":"19f86e39c87e02ae80dbe4459a37a9bf","name":"CP048478.zip","release":"2021-08-26T11:44:47","revision":"0","sha1sum":"a7d8b60aa8265e4103613822054b504192381511","size":"19MB","target_guids":["4d2340a5-304f-3130-3630-304b57564e42","4d2340a5-304f-3330-3230-304b57564e43","4d2340a5-304f-3630-3430-304b57564e44","4d2340a5-3054-3130-3630-304b57535442","4d2340a5-3054-3330-3230-304b57535443","4d2340a5-3054-3630-3430-304b57535444"],"type_of_change":"1","version":"HPK3","vib_list":[{"name":"CP048478","version":"HPK3.4-7.0.0.15843807"}]}],"id":{"product":"a2580f8b900b4c35b050bbb3d0fe3010","version":"4e5072c0b6264b18b95611f6d1e235b8"},"installation":{"command":"CP040194.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MO001600KWVNB, MO003200KWVNC, MO006400KWVND, MT001600KWSTB, MT003200KWSTC and MT006400KWSTD Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MO001600KWVNB、MO003200KWVNC、MO006400KWVND、MT001600KWSTB、MT003200KWSTC、およびMT006400KWSTDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO006400KWVND","target_guid":"4d2340a5-304f-3630-3430-304b57564e44","type":"nvme"},{"id":"MO003200KWVNC","target_guid":"4d2340a5-304f-3330-3230-304b57564e43","type":"nvme"},{"id":"MO001600KWVNB","target_guid":"4d2340a5-304f-3130-3630-304b57564e42","type":"nvme"},{"id":"MT001600KWSTB","target_guid":"4d2340a5-3054-3130-3630-304b57535442","type":"nvme"},{"id":"MT003200KWSTC","target_guid":"4d2340a5-3054-3330-3230-304b57535443","type":"nvme"},{"id":"MT006400KWSTD","target_guid":"4d2340a5-3054-3630-3430-304b57535444","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T18:03:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Fixed SSD weargauge report error issue.</li>\n\t<li>Fixed Assign FWState as TR_DONE_ERR at the correct location.</li>\n\t<li>Prepare proper response data for Get Message Type Supported MCTP Command.</li>\n\t<li>Added code to preserve current feature values cross live firmware update.</li>\n\t<li>Allocate 4 bytes instead of 2 bytes for parameter code.</li>\n\t<li>Changed the value for NLB equal to NSize -1.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT006400KWSTD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWVNB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT003200KWSTC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO003200KWVNC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO006400KWVND","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWSTB","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"Provides miscellaneous utilities in support of the HPE supported Fibre Channel host bus adapter drivers."},{"lang":"ja","x_late":"HPEのサポートされるファイバーチャネルホストバスアダプタードライバーのサポートに各種ユーティリティを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"26634","datemodified":"2021-12-21T06:50:01","file_list":["./etc/.hp_fibreutils","./opt/hp/hp_fibreutils/adapter_info","./opt/hp/hp_fibreutils/hp_rescan","./opt/hp/hp_fibreutils/lssd","./opt/hp/hp_fibreutils/lssg","./opt/hp/hp_fibreutils/scsi_info","./usr/bin/adapter_info","./usr/bin/hp_rescan","./usr/bin/lssd","./usr/bin/lssg","./usr/bin/scsi_info","./usr/share/smartupdate/fibreutils/component.xml"],"md5sum":"ab2ace839a40a6bda91ad549a8a167e7","name":"fibreutils-4.2-1_sles.x86_64.rpm","release":"2021-12-21T06:49:21","revision":"0","sha1sum":"7b669ed8f6fb9694b6e81b5a82f41c7a21ec16cd","size":"26KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec33366d5a"],"type_of_change":"0","version":"4.2-1"}],"id":{"product":"a32bfc6464f84b51997e9a09f493113b","version":"f7821120d0f749999eacd78971220c6b"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download fibreutils RPM. <BR>Use rpm -Uvh command to install/upgrade RPM."},{"lang":"ja","x_late":"fibreutils RPMをダウンロードしました。<BR>RPMをインストール/アップグレードするには、rpm -Uvhコマンドを使用します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Fibreutils for HPE Storage Fibre Channel Host Bus Adapters for Linux -SuSE Linux Enterprise Server(SLES)"},{"lang":"ja","x_late":"Fibreutils for HPE Storageファイバーチャネルホストバスアダプター for Linux - SuSE Linux Enterprise Server(SLES)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:05","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This package supports only SuSE Linux Enterprise Server(SLES) Distros</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"fibreutils","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 1Gb 2-port 363i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1523103C1989","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Communication Board","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521159000FF","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C3380","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D0","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 560SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10FB103C17D3","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"10.57.2"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C211A","Version":"1.3089.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 561FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":360,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1528103C192D","Version":"1.3089.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"tw","x_late":"本套件包含可升級 HPE Intel 乙太網路網路卡 ROM 映像的公用程式和二進位檔，適用於 Linux x86_64 平台。"},{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Intel Ethernet NICs ROM images running under Linux x86_64 platform."},{"lang":"ko","x_late":"이 패키지에는 Linux x86_64 플랫폼에서 실행되는 HPE Intel Ethernet NICs ROM 이미지를 업그레이드할 수 있는 유틸리티와 바이너리가 포함되어 있습니다."},{"lang":"cn","x_late":"该软件包包含实用程序和二进制文件，可用于升级在Linux x86_64平台下运行的HPE Intel以太网卡ROM映像。"},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE Intel Ethernet NIC ROMイメージをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>Single NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361i Adapter</td>\n\t\t\t<td>8000106F</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 361T Adapter</td>\n\t\t\t<td>80001147</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 363i Adapter</td>\n\t\t\t<td>80000D00</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Communication Board</td>\n\t\t\t<td>80000EBF</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366i Adapter</td>\n\t\t\t<td>8000105E</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366FLR Adapter</td>\n\t\t\t<td>80001148</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 366T Adapter</td>\n\t\t\t<td>80001146</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368i Adapter</td>\n\t\t\t<td>80003373</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter</td>\n\t\t\t<td>80003370</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 1Gb 4-port 369i Adapter</td>\n\t\t\t<td>80003371</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLR-SFP+ Adapter</td>\n\t\t\t<td>800009E0</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560SFP+ Adapter</td>\n\t\t\t<td>800009E1</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561T Adapter</td>\n\t\t\t<td>80000636</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</td>\n\t\t\t<td>800005B6</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568i Adapter</td>\n\t\t\t<td>80003372</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter</td>\n\t\t\t<td>80003370</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</td>\n\t\t\t<td>80003370</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 563i Adapter</td>\n\t\t\t<td>800035C0</td>\n\t\t\t<td>1.1375.0</td>\n\t\t\t<td>N/A</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter</td>\n\t\t\t<td>8000B749</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>10.57.2</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562FLR-T Adapter</td>\n\t\t\t<td>800016F1</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>10.55.3</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562SFP+ Adapter</td>\n\t\t\t<td>8000B748</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>10.57.2</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 562T Adapter</td>\n\t\t\t<td>800016EF</td>\n\t\t\t<td>1.3089.0</td>\n\t\t\t<td>10.55.3</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.3089.0 includes: Boot Agent: 1GbE - v1.5.89, 10GbE - v2.4.45, 40GbE - v1.1.31 &amp; UEFI Drivers: 1GbE - v9.7.06, 10GbE - v8.1.00, 40GbE - v4.8.08</p>\n\n<p>The combo image v1.1375.0 includes: Boot Agent: 1GbE - v1.5.72, 10GbE - v2.3.46, 40GbE - v1.0.21 &amp; UEFI Drivers: 1GbE - v6.9.13, 10GbE - v5.0.20, 40GbE - v1.5.14</p>\n\n<p>Single NVM Version is new firmware format which represent an unified version in place of the previously used EEPROM/NVM Version or OROM version.</p>\n"}],"files":[{"bytes":"11133542","datemodified":"2021-11-01T17:04:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/CP049894.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/CP049894.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000106F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_363i_I350_2p_KX_NCSI_LS_80000D00.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366FLR_G41713-00x_80001148.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366FLR_G41713-00x_80001148.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366T_Quad_H73104-00x_80001146.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366T_Quad_H73104-00x_80001146.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_00FF_1590_80000EBF.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_366i_I350_4p_Cu_NCSI_1.61_8000105E.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_5p50_80003371.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_560FLR-SFP_2_port_G42955-0xx_2.69_800009E0.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_561FLR-T_G74768-000_update_EDC_2.19_800005B6.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_561T_OCSD_G88062-000_E1_2.46_80000636.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_10p57p2_8p50_8000B749.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_562SFP_DP_H44490-000_10p57p2_8p50_8000B748.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_5p50_80003372.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_5p50_80003370.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_5p50_80003373.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx_800009E1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_SFX_OCSD_G43260-0xx_800009E1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.22.50-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049894.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049894.scexe"],"md5sum":"d9466cdbe119e6b5ac0c8db3ceb4a5c4","name":"firmware-nic-intel-1.22.50-1.1.x86_64.rpm","release":"2021-11-01T16:51:47","revision":"0","sha1sum":"cbe79d34677db60a8418d94d29c561771eb26b1c","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-1523103C1989","a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-1521159000FF","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C337F","a6b1a447-382a-5a4f-8086-1521103C3380","a6b1a447-382a-5a4f-8086-10FB103C17D0","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-10FB103C17D3","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1528103C211A","a6b1a447-382a-5a4f-8086-1528103C192D"],"type_of_change":"1","version":"1.22.50"}],"id":{"product":"d8c86b5c3ce7444dbebf7bd215bf1a32","version":"e8cb4298fdd24073bf56716c241b8a4e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong><em><strong><em><strong><em><strong>Updating firmware with rpm installed:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>Install the NIC firmware rpm using the commmand:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<br />\n\t<li>The CP047024.scexe script is located in the &#39;scexe-compat&#39; folder. Further information&nbsp;is available in CP045035.txt file in the &#39;firmware-nic-*&#39; folder. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above.</li>\n\t<br />\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li><em>./</em>CP047024<em>.scexe</em> in the &#39;/usr/lib/x86_64-linux-gnu&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;firmware-nic-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><br />\n<em><strong>Updating firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<br />\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run <em>./hpsetup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<br />\n\t<li>&nbsp;</li>\n</ul>\n\n<p><em><strong>Additional Information:</strong></em></p>\n\n<ul>\n\t<li>Under certain scenarios, after updating the EPROM you may be required to reboot the&nbsp;system and re-run the component&nbsp;in order&nbsp;to update the flash ROM (OROM) on the adapter(s).</li>\n\t<li>The results of the firmware upgrade are saved in the CP047024.log file, located at the /var/cpq/ directory.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the firmware rpm package (rpm -ivh) does not update the adapter firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the adapter requires following the&nbsp;above outlined steps.&nbsp;</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed. For more information about downgrade limitation, refer to the following Customer advisory:&nbsp;<br />\n\t<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</a></li>\n\t<li>AC Power Cycle is required after firmware installation for updates&nbsp;to take effect for the following network adapters:<br />\n\tHPE Ethernet 1Gb 2-port 368i Adapter<br />\n\tHPE Ethernet 1Gb 4-port 369i Adapter<br />\n\tHPE Ethernet 1Gb 2-port 368FLR-MMT Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter<br />\n\tHPE Ethernet 10Gb 2-port 568FLR-MMT Adapter</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><em><strong><em><strong><em><strong><em><strong>rpmインストールによるファームウェアのアップデート:</strong></em></strong></em></strong></em></strong></em></p>\n\n<ul>\n\t<li>次のコマンドを使用して、NICファームウェアをインストールします：  <em>rpm -ivh <rpm_filename>.rpm.  </em>これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<br />\n\t<li>CP047024.scexeスクリプトは 'scexe-compat' フォルダーにあります。詳細については、'firmware-nic-*'フォルダーのCP045035.txtファイルを参照してください。firmware-nic-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<br />\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li><em>./</em>CP047024<em>.scexe</em>（'/usr/lib/x86_64-linux-gnu'内）（または）</li>\n\t\t<li>firmware-nic-*ロケーションの<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>rpmをアンインストールするには、次のコマンドを実行します：<em>rpm -e <rpm_package_name></em></li>\n</ul>\n\n<p><br />\n<em><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></em></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<br />\n\t<li>usr/lib/x86_64-linux-gnu/firmware-nic-*ロケーションに移動し、<em>./hpsetup</em>を実行してファームウェアをアップデートします。'firmware-nic-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<br />\n\t<li> </li>\n</ul>\n\n<p><em><strong>追加情報:</strong></em></p>\n\n<ul>\n\t<li>特定のシナリオでは、EPROMをアップデートした後にシステムを再起動して、アダプターのフラッシュROM（OROM）をアップデートするためにコンポーネントの再実行を要求されることがあります。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにある\"CP047024.log\"ファイルに保存されます。</li>\n\t<li>ファームウェアのアップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</li>\n\t<li>ファームウェアrpmパッケージのインストール（rpm -ivh）は、アダプターのファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。アダプターのファームウェアをアップデートするには、上記の手順に従う必要があります。 </li>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。ダウングレードに関する制限について詳しくは、次のカスタマーアドバイザリを参照してください。 <br />\n\t<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us</a></li>\n\t<li>次のネットワークアダプターについては、アップデートを反映させるためにファームウェアのインストール後に電源を再投入する必要があります。<br />\n\tHPE Ethernet 1Gb 2ポート 368i アダプター<br />\n\tHPE Ethernet 1Gb 4ポート369iアダプター<br />\n\tHPE Ethernet 1Gb 2ポート368FLR-MMTアダプター<br />\n\tHPE Ethernet 10Gb 2ポート 568FLR-MMSFP+アダプター<br />\n\tHPE Ethernet 10Gb 2ポート568FLR-MMTアダプター</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"HPE Intel 線上韌體升級公用程式 (適用於 Linux x86_64)"},{"lang":"en","x_late":"HPE Intel Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE Intel 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE Intel 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Intelオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"1523","subdev":"1989","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1523103c1989","type":"pci","ven":"8086"},{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00FF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1521159000ff","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1521","subdev":"337F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c337f","type":"pci","ven":"8086"},{"dev":"1521","subdev":"3380","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-1521103c3380","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1521","subdev":"339E","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c339e","type":"pci","ven":"8086"},{"dev":"1521","subdev":"17D1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c17d1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"8157","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1521103c8157","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T07:02:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4 and SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"INTEL","sw_key_expectedpath":"firmware:intel_nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"XP0120GFJSL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3132-3047464a534c","Version":"HPS4"},{"DeviceName":"XP0240GFJSN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"ASAXHPS4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5800-3050-3234-3047464a534e","Version":"HPS4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: XP0120GFJSL and XP0240GFJSN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - &nbsp;XP0120GFJSL and XP0240GFJSN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPS2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPS2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3596280","datemodified":"2021-07-25T19:48:04","file_list":["ASAXHPS4.rel","cp048646.xml","cpqsetup.exe","payload.json","setup.dll"],"md5sum":"53cf6b7eed55904a855add4083ef075a","name":"cp048646.exe","release":"2021-07-25T19:40:05","revision":"0","sha1sum":"3a6a62c104f43241946e3ea9ed119c214ae0e745","size":"3MB","target_guids":["002340a5-5800-3050-3132-3047464a534c","002340a5-5800-3050-3234-3047464a534e"],"type_of_change":"1","version":"HPS4"}],"id":{"product":"c1ebf0647264498cacbe8929505ef3cf","version":"dfb2310430084a9da6b67e24ec6fc4a7"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - XP0120GFJSL and XP0240GFJSN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - XP0120GFJSLおよびXP0240GFJSNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"XP0120GFJSL","target_guid":"002340a5-5800-3050-3132-3047464a534c","type":"sata"},{"id":"XP0240GFJSN","target_guid":"002340a5-5800-3050-3234-3047464a534e","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T18:08:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"XP0120GFJSL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"XP0240GFJSN","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 6.7 Fibre Channel Driver kit for HPE Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"735985","datemodified":"2021-08-26T11:30:48","file_list":["/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip","/cp046793.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/vib20/lpfc/EMU_bootbank_lpfc_12.8.528.14-1OEM.670.0.0.8169922.vib","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vmware.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/vibs/lpfc--6885805289219874139.xml","/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922-offline_bundle-18484921.zip/metadata.zip/bulletins/Broadcom-ELX-lpfc_12.8.528.14-1OEM.670.0.0.8169922.xml"],"md5sum":"e62813c81e5ace325d7886fd8dc95e5a","name":"cp046793.zip","release":"2021-08-26T11:30:03","revision":"0","sha1sum":"3486be5b57b6a944694b7c0e00583e81c686ca95","size":"718KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec31dc6180"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"lpfc","version":"12.8.528.14-1OEM.670.0.0.8169922"}]}],"id":{"product":"3992c4a617964c62b374bf1d689252da","version":"3e9c90af6d3c4ad781c4822261a8803f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>&nbsp;<strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel driver component for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:54","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Changed the default Logical Unit Number (LUN) queue depth from 30 to 64</li>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability&nbsp;&nbsp;</li>\n</ul>\n\n<p dir=\"LTR\">Updated to Driver version 12.8.317.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.14</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"lpfc:12.8.528.14-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The HPE Storage Fibre Channel (FC) adapter kit contains version 12.8.351.7 of the Emulex Storport driver for Extended Systems which provides Mezzanine Fibre Channel-Host Bus Adapter (HBA) driver support for HPE Storage RAID Arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2310008","datemodified":"2021-08-27T10:52:56","file_list":["cp046791.xml","cpqsetup.exe","elxdrvr-fc-12.8.351.7-13.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"md5sum":"70c9bbdd506295b8bc22ddb533509f7c","name":"cp046791.exe","release":"2021-08-27T10:50:32","revision":"0","sha1sum":"3f5c7d36200ab1d032aef0373c01f1c7eac31e51","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"type_of_change":"1","version":"12.8.351.7"}],"id":{"product":"d40709c9a4334c3ab0e384d0ba51692d","version":"0c503d198d504716901f6ea387a429d6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version&nbsp;12.8.334.6</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version&nbsp;12.8.351.7</p>\n\n<p>The raw driver files can be obtained by extracting the Smart Component and then extracting the Emulex installer.&nbsp; Use this command:</p>\n\n<p>&nbsp;&nbsp;&nbsp; elxdrvr-fc-version.exe /q2 extract=2</p>\n\n<p>The extracted files are located:</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version</p>\n\n<p>Each kit folder has subsequent architecture folders with subsequent OS folders.&nbsp; For example,</p>\n\n<p>&nbsp;&nbsp;&nbsp; C:\\Users\\Administrator\\Documents\\Emulex\\Drivers\\FC-version\\x64\\win2019</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"elxfc.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 7.0"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 7.0上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"30657063","datemodified":"2022-02-05T14:19:25","file_list":["/CP050379.vmexe64","/CP050379.vmfile","/CP050379.xml","/CP050379_VMw.zip","/payload.json","/README.txt","/CP050379_VMw.zip/index.xml","/CP050379_VMw.zip/vendor-index.xml","/CP050379_VMw.zip/metadata.zip","/CP050379_VMw.zip/vib20/CP050379/HPE_bootbank_CP050379_1.0.0-7.0.0.15525992.vib","/CP050379_VMw.zip/metadata.zip/vendor-index.xml","/CP050379_VMw.zip/metadata.zip/vmware.xml","/CP050379_VMw.zip/metadata.zip/vibs/CP050379--4268909498183563114.xml","/CP050379_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050379_1.0.0-7.0.0.15525992.xml"],"md5sum":"811d3e54a28159b3dfd707e777b967fc","name":"CP050379.zip","release":"2022-02-05T17:06:43","revision":"0","sha1sum":"b5637ae142ab7da97a4c22b5765b42ff4f190015","size":"29MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050379","version":"1.0.0-7.0.0.15525992"}]}],"id":{"product":"15d448815a234025a6958f5176b1dc77","version":"ba9e0608ac9847f9bb52bb5e7926c1f4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Download the appropriate SPP</li>\n\t<li>&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>&nbsp; &nbsp; Run SUM</li>\n\t<li>&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;</li>\n\t<li>&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></li>\n</ul>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;</li>\n\t<li>&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;</li>\n\t<li>&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Enable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;</li>\n\t<li>&nbsp; &nbsp; Place the Smart Component in a temporary directory</li>\n\t<li>&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst</li>\n\t<li>&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst</li>\n\t<li>&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe</li>\n\t<li>&nbsp; &nbsp; Follow the directions given by the Smart Component.</li>\n\t<li>&nbsp; &nbsp; Logout.</li>\n\t<li>&nbsp; &nbsp; Disable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 7.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 7.0"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ（ESXi 7.0）for HPE Mellanox VPI（EthernetおよびInfinibandモード）ConnectX4およびConnectX5デバイス - VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T06:46:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1200:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>&nbsp;&nbsp;Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and&nbsp;&nbsp;the DQPN.</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). <strong>Note:</strong> If the port does not go up, switch to Force mode.</li>\n</ul>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li>\n\t<li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li>\n\t<li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New Features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixes an issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed n issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel Adapter and mezzanine host bus adapters. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4169860","datemodified":"2021-08-26T08:53:04","file_list":["./etc/dracut.conf.d/qla2xxx.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/4.12.14-120-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"md5sum":"00c9ae12e3e17ea3b3f0a76f083db1b7","name":"qlgc-qla2xxx-kmp-default-10.02.01.00.a14_k1_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-26T08:46:09","revision":"0","sha1sum":"ff1541e7d1fedeb907e7000c732edbff140b6de0","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"type_of_change":"1","version":"10.02.01.00.a14-k1"}],"id":{"product":"933e42b273b146ee8ce7b3d90a74c2b2","version":"28d2f73ca123498e95cac629ca153030"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh qlgc-qla2xxx-4.6.28-20.sles12sp2.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e qlgc-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh kmod-qla2xxx-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) Capability</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Improve detection and recovery from conditions described in customer advisory available at <a href=\"http://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated to driver version 10.02.01.00.a14-k1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlgc-qla2xxx-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"218.0.303000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"218.0.303000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"218.0.303000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"218.0.303000"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NIC firmware running under Linux x86_64 platforms."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant Broadcom NetXtreme-E Gigabit Ethernet NICをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 218.0.303000&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>Bootcode Version</th>\n\t\t\t<th>NCSI Version</th>\n\t\t\t<th>MBA Version</th>\n\t\t\t<th>UEFI Version</th>\n\t\t\t<th>CCM Version</th>\n\t\t\t<th>RoCE Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 535FLR-T Adapter</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">&nbsp; &nbsp; 218.0.229.0<br />\n\t\t\t&nbsp;</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">&nbsp;218.0.173.0<br />\n\t\t\t&nbsp;</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">218.0.38.0<br />\n\t\t\t&nbsp;</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">&nbsp;218.0.93.0<br />\n\t\t\t&nbsp;</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">218.0.28.0<br />\n\t\t\t&nbsp;</td>\n\t\t\t<td colspan=\"1\" rowspan=\"7\">&nbsp;218.0.5.0<br />\n\t\t\t&nbsp;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 535T Adapter</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 537SFP+ Adapter&nbsp;</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"6926198","datemodified":"2022-02-07T10:16:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/CP050624.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/CP050624.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.12.1-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050624.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050624.scexe"],"md5sum":"c82a3dcac2fcfe62fb0a6f395b74deac","name":"firmware-nic-bcm-nxe-1.12.1-1.1.x86_64.rpm","release":"2022-02-07T10:08:27","revision":"0","sha1sum":"841cb7c1dd69faf27a417334aad2d7dbbad2bd64","size":"6MB","target_guids":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"type_of_change":"1","version":"1.12.1"}],"id":{"product":"7dbb2b9a498c4df1a461e7b3079cc8f5","version":"c781f60a0314444789bf8839abfab860"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Updating adapter firmware with rpm installed:</strong></em></p>\n\n<ul>\n\t<li>Install this NIC firmware rpm with the following command: <em>rpm -ivh &lt;rpm_filename&gt;.rpm.&nbsp; </em></li>\n</ul>\n\n<p style=\"margin-left:80px\">This command will extract the contents&nbsp;to &quot;/usr/lib/x86_64-linux-gnu.&quot;<br />\nThe CP050624.scexe script&nbsp;is located in the &quot;scexe-compat&#39;&#39; folder. Further information&nbsp;is available in CP050624.txt file in the &quot;firmware-nic-*&quot; folder. The actual name of the &quot;firmware-nic-*&quot; folder is&nbsp;based on the version of the rpm to be installed.&nbsp;&nbsp;</p>\n\n<ul>\n\t<li>To install the firmware, execute <strong>ONE</strong> of the following commands:\n\n\t<ul>\n\t\t<li><em>./</em>CP050624<em>.scexe</em>&nbsp;in the&nbsp;&quot;/usr/lib/x86_64-linux-gnu/scexe-compat&quot; location.</li>\n\t\t<li><em>./setup</em>&nbsp;in the &quot;firmware-nic-*&quot; location.&nbsp;&nbsp;&nbsp;</li>\n\t</ul>\n\t</li>\n\t<br />\n\t<li>To uninstall this rpm,&nbsp;execute the&nbsp;folllowing command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em></li>\n</ul>\n\n<p><em><strong>Updating adapter firmware without installing the rpm:</strong></em></p>\n\n<ul>\n\t<li>Extract the contents of the rpm with the following command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</em></li>\n</ul>\n\n<p style=\"margin-left:80px\">This will extract the contents of the rpm to the &quot;usr&quot; folder in the current directory.</p>\n\n<ul>\n\t<li>Navigate to the&nbsp;&quot;usr/lib/x86_64-linux-gnu/firmware-nic-*&quot; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is based on the version of the&nbsp;rpm.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>The results of the firmware upgrade are saved&nbsp;in CP050624.log at &quot;/var/cpq/.&quot;</li>\n\t<li>The Device ID will change when NPAR (NIC Partitioning) mode is enabled. Accordingly adapters with DID 0x16D7 and 0x16D8 will change to 0x16EC and 0x16EE respectively if&nbsp; NPAR is enabled but RoCE is disabled and to 0x16ED and 0x16EF respectively if NPAR is enabled and RoCE is also enabled.</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware. Installing the rpm merely extracts the rpm content to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n\t<li>When&nbsp;upgrading firmware, refer to Revision History and upgrade it to the following version as stepping up the ladder until the version needed.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eオンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-22T05:25:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where network interface could not be brought up under OS.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue a packet missing problem after some amounts of multicast UDP streams transmitted.</li>\n\t<li>This product addresses an issue the port identifier LED problem on HPE Ethernet 10Gb 2-port 535T Adapter .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"BCM_NXE","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U32_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11626664","datemodified":"2022-03-08T11:08:14","file_list":["cp051168.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_2.62_03_08_2022.signed.flash"],"md5sum":"6ed5838dce27cb6c6a45e06def1b800a","name":"cp051168.exe","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"72033a095cde78ef59880b1e3c10e71e0f655d75","size":"11MB","target_guids":["00000000-0000-0000-0000-000000000204"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"36877a0ed97d40a29cfe6cb469a6e72f","version":"4857bf9ef21f4966adfa7dc66a651d1d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL360 Gen10 (U32)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:30","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"}],"sw_keys":[{"name":"U32","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the HPE iavf driver for Intel i40ea and Intel i40eb Ethernet NICs running under Microsoft Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1349576","datemodified":"2022-01-25T15:48:40","file_list":["cp049687.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"5ef08fd1610307cae80e1daf0d89bdea","name":"cp049687.exe","release":"2022-01-25T15:33:28","revision":"0","sha1sum":"c67c186d9b0aa28fad90fe182ddff92afd65ca60","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"type_of_change":"1","version":"1.13.8.0"}],"id":{"product":"30c69f83193c4f679a84938a219df0d6","version":"f609f2dc929a45bf8c1420e75f957155"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel iavf Driver for Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"37CD","subdev":"0000","subven":"1590","target_guid":"","type":"pci","ven":"8086"},{"dev":"37CD","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-37cd80860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"103c","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-04T00:01:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial version.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"iavf.sys","sw_key_expectedpath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0400JEABD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3430-304a45414244","Version":"HPD4"},{"DeviceName":"VK0800JEABE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3830-304a45414245","Version":"HPD4"},{"DeviceName":"VO1600JEABF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAPM2RD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314f-3630-304a45414246","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK0400JEABD, VK0800JEABE, and VO1600JEABF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK0400JEABD、VK0800JEABE、およびVO1600JEABF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online HDD/SSD Flash Component for VMware ESXi - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15933311","datemodified":"2021-08-31T11:11:39","file_list":["/CP049410_BUILD_1.data","/CP049410.vmexe","/CP049410.vmexe64","/CP049410.vmfile","/CP049410_VMw.zip","/CP049410.xml","/payload.json","/CP049410_VMw.zip/index.xml","/CP049410_VMw.zip/vendor-index.xml","/CP049410_VMw.zip/metadata.zip","/CP049410_VMw.zip/vib20/CP049410/HPE_bootbank_CP049410_HPD4.1-7.0.0.15843807.vib","/CP049410_VMw.zip/metadata.zip/vendor-index.xml","/CP049410_VMw.zip/metadata.zip/vmware.xml","/CP049410_VMw.zip/metadata.zip/vibs/CP049410--57547943028718795.xml","/CP049410_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049410_HPD4.1-7.0.0.15843807.xml"],"md5sum":"c09bbb34d1c6db1508a9c42bd9c704ba","name":"CP049410.zip","release":"2021-08-31T11:07:09","revision":"0","sha1sum":"07a5c9c337b74d02ee6c540dbeb07f9c4ffb6654","size":"15MB","target_guids":["002340a5-5600-304b-3430-304a45414244","002340a5-5600-304b-3830-304a45414245","002340a5-5600-314f-3630-304a45414246"],"type_of_change":"2","version":"HPD4","vib_list":[{"name":"CP049410","version":"HPD4.1-7.0.0.15843807"}]}],"id":{"product":"07a177efdb914ccfaea8cc2d7cc450db","version":"88395a535d3d4b02879c40ed89b30f46"},"installation":{"command":"CP031687.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK0400JEABD, VK0800JEABE, and VO1600JEABF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK0400JEABD、VK0800JEABE、およびVO1600JEABFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO1600JEABF","target_guid":"002340a5-5600-314f-3630-304a45414246","type":"sas"},{"id":"VK0400JEABD","target_guid":"002340a5-5600-304b-3430-304a45414244","type":"sas"},{"id":"VK0800JEABE","target_guid":"002340a5-5600-304b-3830-304a45414245","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T10:15:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>If Power On Hours exceeds 70,000hrs, PM2R will report Hardware error (04/4C/A8) after the next Power Cycle and will not accept read/write commands. This fix will update storage location reporting when the maximum number of registrations in the Work Load Log read process reaches 70,000; the last registered 70,000th storage location will be modified to be read as the next (70,001st) storage location.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111296en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0400JEABD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO1600JEABF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VK0800JEABE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMは、HPE Storageファイバーチャネルアダプターおよびメザニンホストバスアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"582791","datemodified":"2021-11-17T05:24:11","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"ab8e6b2dcba69521d802e6491b546c5e","name":"elx-lpfc-kmp-default-12.8.528.7_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-11-17T05:11:44","revision":"0","sha1sum":"814d255afad2b4875bd808354f6968fe998824c8","size":"569KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"ff62b7c54afa40698c7ab166c3e4526e","version":"391c16c7a040497badcce0a498173b82"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;replacepkgs --nodeps</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"},{"lang":"ja","x_late":"<p>1.  システム管理者 (root) としてログインします。</p>\n\n<p>2.  RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3.  ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。</p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p>\n\n<p>同じドライバーバージョンの書き換えは、–forceまたは--replacepkgsと--nodepsオプションを使用して実行する必要があります</p>\n\n<p>例：rpm –Uvh elx-lpfc-kmp-default-<version>.<OSupdate>.x86_64.rpm –force --nodeps</p>\n\n<p>                rpm –Uvh elx-lpfc-kmp-default-<version>.<OSupdate>.x86_64.rpm –replacepkgs --nodeps</p>\n\n<p>詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 Service Pack 5ファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプターおよびメザニンホストバスアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1229883","datemodified":"2021-03-08T20:10:56","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf","./lib/modules/5.3.18-22-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"7e10600de1fa70c3be7a3603d5327a93","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"982971925273ba8a69c6294818608eb516283686","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"},{"bytes":"1051883","datemodified":"2021-03-08T20:13:47","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf","./lib/modules/4.12.14-195-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf_bl-kmp-default/component.xml"],"md5sum":"50ad8b53edcccb1285ff8d3ed3b04f85","name":"hp-ixgbevf_bl-kmp-default-4.9.3_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:10","revision":"0","sha1sum":"8b114edaae92c28d45a32b0d846154fe71edcd7e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec93bdb747"],"type_of_change":"0","version":"4.9.3-1"}],"id":{"product":"d05081ab9ef4444a874a5310ab9eff91","version":"d563d7b60897419bb0d727b5ecae0aac"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Intel ixgbevfドライバーfor SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"<p>This product corrects an issue seen when enabling SRIOV, where the VFs have the same, duplicated MAC address.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbevf_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE QMH2672 16GB FC HBA for c-Class BladeSystem","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//hld60404.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2031103C1939","Version":"06.04.04"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of HPE QLogic Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"8768198","datemodified":"2021-08-25T09:26:03","file_list":["/CP046777_BUILD_4.data","/CP046777.vmexe","/CP046777.vmexe64","/CP046777.vmfile","/CP046777_VMw.zip","/CP046777.xml","/payload.json","/CP046777_VMw.zip/index.xml","/CP046777_VMw.zip/vendor-index.xml","/CP046777_VMw.zip/metadata.zip","/CP046777_VMw.zip/vib20/CP046777/HPE_bootbank_CP046777_2021.09.01.4-6.7.0.7535516.vib","/CP046777_VMw.zip/metadata.zip/vendor-index.xml","/CP046777_VMw.zip/metadata.zip/vmware.xml","/CP046777_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046777_2021.09.01.4-6.7.0.7535516.xml","/CP046777_VMw.zip/metadata.zip/vibs/CP046777-7250187560311741295.xml"],"md5sum":"3345624403c77daa2db8a21e6db6ebb7","name":"CP046777.zip","release":"2021-08-25T09:20:27","revision":"0","sha1sum":"2f237b0848860d0a60a4c578a7b1a22fbefdf85a","size":"8MB","target_guids":["a6b1a447-382a-5a4f-1077-2031103C1939"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046777","version":"2021.09.01.4-6.7.0.7535516"}]}],"id":{"product":"8dd88e1b96d74e199d82e65682ededf4","version":"dedce00c6ccd49f38359364d1975af99"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a behavior where the Unified Extensible Firmware Interface (UEFI) driver would force the system to reboot if one or both ports of a mezzanine adapter were not connected to an interconnect module during boot.</li>\n\t<li>Fixed a behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Updated&nbsp;the Firmware/BIOS/UEFI packages for&nbsp;16 Gb&nbsp;products.</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE QMH2672 16Gb Fibre Channel Host Bus Adapter for c-Class BladeSystem</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 10Gb 2-port 560FLB Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C18D0","Version":"1.2836.0"},{"DeviceName":"HP Ethernet 10Gb 2-port 560M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":60,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-10F8103C17D2","Version":"1.2836.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component contains utilities and firmware for the online upgrade of HPE Blade Intel NIC firmware running under Microsoft Windows Server 2012 R2, Windows Server 2016 and Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントには、Windows Server 2012 R2、Windows Server 2016、およびWindows Server 2019で動作するHPE Blade Intel NICファームウェアをオンラインでアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported nework adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM/NVM Version</th>\n\t\t\t<th>OROM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560FLB Adapter</td>\n\t\t\t<td>800008F0</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 560M Adapter</td>\n\t\t\t<td>8000083D</td>\n\t\t\t<td>1.2836.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2836.0 includes: Boot Agent: 1GbE - v1.5.88, 10GbE - v2.4.44, 40GbE - v1.1.18&nbsp;&amp; UEFI Drivers: 1GbE - v9.4.06, 10GbE - v7.8.13, 40GbE - v4.4.12</p>\n"}],"files":[{"bytes":"5870424","datemodified":"2021-08-12T02:42:24","file_list":["BNICOFUT.pdf","cp047539.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_560FLB_G33590-000_2.45_800008F0.txt","FW/HPE_560M_G43498-00X_2.18_8000083D.txt","FW/HPE_XG_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/BNICOFUT_JA.pdf","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/BNICOFUT_ZHCN.pdf"],"md5sum":"fcf3190fa85044e8c9402cb91414646d","name":"cp047539.exe","release":"2021-08-12T02:33:29","revision":"0","sha1sum":"2f93fa5f08354bd7bcf79569c59942511553f50a","size":"5MB","target_guids":["a6b1a447-382a-5a4f-8086-10F8103C18D0","a6b1a447-382a-5a4f-8086-10F8103C17D2"],"type_of_change":"0","version":"1.0.5.2"}],"id":{"product":"5676950ebe02418986b260051b7d33cb","version":"d6bd63b522764028981e90034cb2462a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.1.197.0","description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"name":"Windows","value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When updating&nbsp;firmware, refer to the Revision History and update&nbsp;to the next version as stepping up or down the ladder until the version needed is reached. For more information about downgrade limitations, refer to the following Customer advisory:&nbsp;https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_us.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p> </p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきながら、次のバージョンにアップデートします。ダウングレードに関する制限について詳しくは、カスタマーアドバイザリhttps://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00069764en_usを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Intel Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Blade Intelオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"4100"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This firmware is updated to maintain compatibility with the updated Windows ixn drivers.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product no longer supports Windows Server 2012 R2.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"HPNVMUpdate.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWSRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757535251","Version":"HPG4"},{"DeviceName":"VK000480GWSRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535252","Version":"HPG4"},{"DeviceName":"VK000960GWSRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535254","Version":"HPG4"},{"DeviceName":"VK001920GWSRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757535255","Version":"HPG4"},{"DeviceName":"VK003840GWSRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM883G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757535256","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV "},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRV "}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;- VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and&nbsp;VK003840GWSRV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4485632","datemodified":"2021-07-25T21:08:38","file_list":["cp048657.xml","cpqsetup.exe","GPM883G4.rel","payload.json","setup.dll"],"md5sum":"e1ce8ae22948e4bd9f6088ca04316c68","name":"cp048657.exe","release":"2021-07-25T21:01:04","revision":"0","sha1sum":"66e7d03f62bd3ab83e128c1a695e15dc2c662c05","size":"4MB","target_guids":["562340a5-304b-3030-3234-304757535251","562340a5-304b-3030-3438-304757535252","562340a5-304b-3030-3936-304757535254","562340a5-304b-3130-3932-304757535255","562340a5-304b-3330-3834-304757535256"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"b2ba8bbc89f8475a9e824abb19fcc091","version":"2ab45f9f078544dfb1e6d9a6d1aef563"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWSRQ, VK000480GWSRR, VK000960GWSRT, VK001920GWSRU and VK003840GWSRV  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK000240GWSRQ、VK000480GWSRR、VK000960GWSRT、VK001920GWSRU、およびVK003840GWSRVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK003840GWSRV","target_guid":"562340a5-304b-3330-3834-304757535256","type":"sata"},{"id":"VK001920GWSRU","target_guid":"562340a5-304b-3130-3932-304757535255","type":"sata"},{"id":"VK000960GWSRT","target_guid":"562340a5-304b-3030-3936-304757535254","type":"sata"},{"id":"VK000480GWSRR","target_guid":"562340a5-304b-3030-3438-304757535252","type":"sata"},{"id":"VK000240GWSRQ","target_guid":"562340a5-304b-3030-3234-304757535251","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:14:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWSRU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWSRV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWSRQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWSRT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWSRR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE Intel ixgbenアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.3.0.</p>\n"}],"files":[{"bytes":"203197","datemodified":"2021-11-19T09:59:21","file_list":["/cp047114.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/index.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/vendor-index.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/metadata.zip","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/vib20/ixgben/INT_bootbank_ixgben_1.10.3.0-1OEM.670.0.0.8169922.vib","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/metadata.zip/vibs/ixgben-3750063168236149934.xml","/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922-offline_bundle-18152126.zip/metadata.zip/bulletins/Intel-ixgben_1.10.3.0-1OEM.670.0.0.8169922.xml"],"md5sum":"ee3e0a02c3f9b626ff0ab4b47a1329d2","name":"cp047114.zip","release":"2021-11-19T09:55:06","revision":"0","sha1sum":"7746667205069addc56b059b4febbb9474e4502b","size":"198KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.12.00","vib_list":[{"name":"ixgben","version":"1.10.3.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"ec0645c5197f4d97aa2ef8ed23e39857","version":"666aad13e3af4c389407e30be94edcdc"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE Intel ixgbenドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where non-working MAC anti-spoofing</li>\n\t<li>This product corrects an issue where incorrect values in virtual function counters</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixgben:1.10.3.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter OCP3 for HPE","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXVDA4_FH_3p00_PLDMoMCTP_80008278.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-XXVDA4 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td>\n\t\t\t<td>80008278</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>he combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t\t<th>NVMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター</td>\n\t\t\t<td>80008278</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2992.0は以下を含みます：インテル(R)ブートエージェントICE v2.5.0およびUEFI x64 100ギガビットドライバーv3.0.11。</p>\n"}],"files":[{"bytes":"10517786","datemodified":"2021-08-12T14:14:38","file_list":["HPE_E810_XXVDA4_FH_3p00_PLDMoMCTP_80008278.HPb","HPE_E810_XXVDA4_FH_3p00_PLDMoMCTP_80008278.xml","payload.json"],"md5sum":"7c96fdd0cad0848cb33a8bbf5b41736c","name":"HPE_E810_XXVDA4_FH_3p00_PLDMoMCTP_80008278.fwpkg","release":"2021-09-16T00:00:00","revision":"1","sha1sum":"c80e7c5e589d6ebe7c52d7f96f358f2a5b9610e0","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-159380860005"],"type_of_change":"1","version":"3.00"}],"id":{"product":"955cffa0d4fe4b76923c0ea7afeca0bf","version":"4a295b095e084cd4afbb843f8951879f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。 </li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T08:47:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_XXV4_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEBTP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3238232","datemodified":"2021-07-25T15:10:32","file_list":["cp048610.xml","cpqsetup.exe","HAHC6FG4.rel","payload.json","setup.dll"],"md5sum":"c6acf4324a4bc27a3107a1939dbcadb5","name":"cp048610.exe","release":"2021-07-25T15:03:14","revision":"0","sha1sum":"06b8fe5a0d9c934e55b52273a187feb5b3aba929","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e2d7a4e705f34372b47092c82c533260","version":"defb32a536074500a9b7610c18c6d6d1"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:18:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEPA and MB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17435601","datemodified":"2021-08-26T19:28:27","file_list":["/CP048362_BUILD_2.data","/CP048362.vmexe","/CP048362.vmexe64","/CP048362.vmfile","/CP048362_VMw.zip","/CP048362.xml","/payload.json","/CP048362_VMw.zip/index.xml","/CP048362_VMw.zip/vendor-index.xml","/CP048362_VMw.zip/metadata.zip","/CP048362_VMw.zip/vib20/CP048362/HPE_bootbank_CP048362_HPD5.2-7.0.0.15843807.vib","/CP048362_VMw.zip/metadata.zip/vendor-index.xml","/CP048362_VMw.zip/metadata.zip/vmware.xml","/CP048362_VMw.zip/metadata.zip/vibs/CP048362--1361896709043931304.xml","/CP048362_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048362_HPD5.2-7.0.0.15843807.xml"],"md5sum":"c63fb1ed2f09ca5ac030158842b2c802","name":"CP048362.zip","release":"2021-08-26T19:23:29","revision":"0","sha1sum":"a067cf952ebf794818b1cb89cba54ecfa08c29bc","size":"16MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5","vib_list":[{"name":"CP048362","version":"HPD5.2-7.0.0.15843807"}]}],"id":{"product":"41fb5700b0aa44b2bbeca072e083be4b","version":"b4941fac9e7d4064b631fa965031dd1a"},"installation":{"command":"CP040514.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T12:46:18","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on QLogic Host Bus Adapter on Windows Server 2022"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"1568952","datemodified":"2021-08-17T07:32:15","file_list":["cp047511.xml","cpqsetup.exe","cp_data.xml","get_ss_status.bat","QlSmartSANInstaller.dll","QLSMARTSANVer.exe","qsmartsan_cfg_cn.xml","qsmartsan_cfg_en.xml","qsmartsan_cfg_ja.xml","SmartSanCfg_x64.exe","SmartSAN_Readme.txt","ss_disable.bat","ss_enable.bat"],"md5sum":"392f157bc0882a87d73f1ec97f596e5e","name":"cp047511.exe","release":"2021-08-17T07:30:04","revision":"0","sha1sum":"e654cbabc5c0416e0bb553611ab4afc5336430c7","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdc79ba4d"],"type_of_change":"1","version":"1.0.0.1"}],"id":{"product":"adbad9f6664545a48fbb137f9046902a","version":"877035b964e64af6a71bc878ad24ff97"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<ul>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the &quot;Install&quot; button to proceed with the installation.</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic Smart SAN Enablement Kit for Fibre Channel Host Bus Adapter for Microsoft Windows Server 2022 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-05-12T07:37:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 1.0.0.1</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLSMARTSANVer.exe","sw_key_expectedpath":"%SystemDrive%\\StorageWorks\\Version"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"23740","datemodified":"2021-12-14T16:13:52","file_list":["./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/mst_pci.ko","./lib/modules/5.3.18-57-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"md5sum":"eef5cff857a5be031069564b31062a4a","name":"kernel-mft-mlnx-kmp-default-4.18.0_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-12-14T15:53:43","revision":"0","sha1sum":"40fb736653fe2dc3805de08fb81fbe6cda57752c","size":"23KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"},{"bytes":"7970699","datemodified":"2021-12-14T16:11:06","file_list":["./etc/bash_completion.d/devmon_complete","./etc/bash_completion.d/flint_complete","./etc/bash_completion.d/mft/mft_base_autocomplete","./etc/bash_completion.d/mft/mft_help_to_completion.py","./etc/bash_completion.d/mlxfwreset_complete","./etc/bash_completion.d/mst_complete","./etc/init.d/mst","./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mst","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mstop","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/stedump","./usr/share/man/man1","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/prm_dbs","./usr/share/mft/prm_dbs/hca","./usr/share/mft/prm_dbs/hca/ext","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch","./usr/share/mft/prm_dbs/switch/ext","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/smartupdate/mft/component.xml"],"md5sum":"6a8eb46fab11810e2aaa80aa2704f535","name":"mft-4.18.0-106.sles15sp3.x86_64.rpm","release":"2021-12-14T15:53:43","revision":"0","sha1sum":"3d94ac624c02272392c40093ed49fa0409ea886f","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"type_of_change":"1","version":"4.18"}],"id":{"product":"1ba987f68f464ccdb12940d5adec7c53","version":"179d9b24478843b8a5d9b67307e0a9c4"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\nTo install or upgrade the driver:<br />\n<br />\nIf using 5.3.18.57-default kernel or any future errata:<br />\n<strong># rpm -Uvh kernel-mft-mlnx-kmp-default-4.18.0_k5.3.18_57-1.sles15sp3.x86_64.rpm&nbsp;&nbsp;mft-4.18.0-78.sles15sp3.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox MFT Driver and Firmware Tools for SUSE Linux Enterprise Server 15 SP3 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-15T08:47:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","latest_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Changes and New features in MFT version 4.17:</strong></p>\n\n<ul>\n\t<li>Enabled Anti-rollback protection to prevent old vulnerable firmware versions from being flashed to the device.</li>\n\t<li>Flint now supports the &quot;--activate_delay_sec&quot; flag which performs the activation on the newly burned firmware after the specified delay.</li>\n\t<li>Remote mst device now supports cable devices. The remote cables will be shown on the mst status and can be accessed via the mlxcables tool.</li>\n\t<li>Added support for the following&nbsp;</li>\n\t<li>&nbsp; &nbsp; Parallel firmware burning. Although DMA burning is supported in Virtual Machines as well, burning in such scenarios might be slower than on Physical Machines</li>\n\t<li>&nbsp; &nbsp; Dual Small Form Factor Pluggable(DSFP) modules in mlxlink.</li>\n</ul>\n","curr_fixes_x_late":"<p>MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode.</p>\n\n<p><strong>The following issues have been fixed in MFT version 4.17.</strong></p>\n\n<ul>\n\t<li>Inconsistent flashing of the firmware while using the Intelligent Platform Management Bus/Bridge service.</li>\n\t<li>Occasional disconnections when the connected port was being activated.</li>\n\t<li>Flag &quot;--json&quot; did not work with features that required a user confirmation.&nbsp;</li>\n\t<li>mlxconfig query for the BOOT_INTERRUPT_DIS TLV showed a wrong value in the &quot;current value&quot; field.</li>\n\t<li>mst version returned an incorrect string: &quot;mst, MFT_VERSION_STR built on TOOLS_BUILD_TIME + Git SHA Hash: TOOLS_GIT_SHA&quot;.</li>\n\t<li>MFT tools did not support using combined short flags without a separation between them.</li>\n\t<li>Performing a driver restart while burning the firmware resulted in firmware burning failure and occasionally device was not accessible.</li>\n\t<li>MVPD read errors occurred from the mlxfwmanager during fast reboot.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"},{"name":"kernel-mft-mlnx-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mft","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 6.7"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.7上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"29817914","datemodified":"2022-02-05T14:18:00","file_list":["/CP050378.vmexe","/CP050378.vmfile","/CP050378.xml","/CP050378_VMw.zip","/payload.json","/CP050378_VMw.zip/index.xml","/CP050378_VMw.zip/vendor-index.xml","/CP050378_VMw.zip/metadata.zip","/CP050378_VMw.zip/vib20/CP050378/HPE_bootbank_CP050378_1.0.3-6.7.0.7535516.vib","/CP050378_VMw.zip/metadata.zip/vendor-index.xml","/CP050378_VMw.zip/metadata.zip/vmware.xml","/CP050378_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050378_1.0.3-6.7.0.7535516.xml","/CP050378_VMw.zip/metadata.zip/vibs/CP050378-1541008664028189765.xml"],"md5sum":"34c636e5f9c24b55358547e55d9a74e8","name":"CP050378.zip","release":"2022-02-05T17:08:25","revision":"0","sha1sum":"fdcec8b4e1879f88047f502a4708b66d8c70ef37","size":"28MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP050378","version":"1.0.3-6.7.0.7535516"}]}],"id":{"product":"80a66dc62c31431baffb87b602c0feff","version":"920a37515fcd4025a1d37d610a912602"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Download the appropriate SPP</li>\n\t<li>&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>&nbsp; &nbsp; Run SUM</li>\n\t<li>&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;</li>\n\t<li>&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></li>\n</ul>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;</li>\n\t<li>&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;</li>\n\t<li>&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Enable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;</li>\n\t<li>&nbsp; &nbsp; Place the Smart Component in a temporary directory</li>\n\t<li>&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst</li>\n\t<li>&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst</li>\n\t<li>&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe</li>\n\t<li>&nbsp; &nbsp; Follow the directions given by the Smart Component.</li>\n\t<li>&nbsp; &nbsp; Logout.</li>\n\t<li>&nbsp; &nbsp; Disable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 6.7"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(ESXi 6.7) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T06:46:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1200:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>&nbsp;&nbsp;Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and&nbsp;&nbsp;the DQPN.</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). <strong>Note:</strong> If the port does not go up, switch to Force mode.</li>\n</ul>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li>\n\t<li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li>\n\t<li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New Features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixes an issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed n issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Mellanox CX4LX and CX5 Ethernet NICs for Microsoft Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Mellanox CX4LXおよびCX5 Ethernet NIC for Microsoft Windows Server 2022用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1994832","datemodified":"2021-12-07T10:36:55","file_list":["cp050321.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"ffce65974dc50730bd05b579e9f80619","name":"cp050321.exe","release":"2021-12-07T10:22:05","revision":"0","sha1sum":"ee4d5ae17dfd01fa5c1b827df652e61a6069847d","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"e33bb1d2f7324af98ab1d5f7897ec4b5","version":"08d4ab36ec674c02bc7fbb863e5ed092"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022"},{"lang":"ja","x_late":"HPE Mellanox CX4LXおよびCX5ドライバー for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1018","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900282","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1014","subdev":"00c8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1014159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159002c1","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d3","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1016159000d4","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101815900246","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product correct an issue which cause TCP connection to drop</p>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행 중인 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 SUSE Linux Enterprise Server 12 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4279541","datemodified":"2021-12-09T00:57:38","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"md5sum":"a62a172513bd8e3cc2284f28c82fa6fb","name":"hp-ixgbe-kmp-default-5.13.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-12-09T00:47:17","revision":"0","sha1sum":"2ba1e5dcaef1c195eab4aa067db233520f5c0e88","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"type_of_change":"0","version":"5.13.4-1"}],"id":{"product":"926b8a90acf147dd8614685a9453a0ed","version":"59b85ad80632482a9fc8722633380ecc"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ko","x_late":"SUSE Linux Enterprise Server 12 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 SUSE Linux Enterprise Server 12 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This products enhances the mechanism that enable MDD(Malicious Driver Detection) when SRIOV is disabled.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-ixgbe-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300032","languages":[{"lang":"fr","x_late":"Pilote - Gestion du système"},{"lang":"en","x_late":"Driver - System Management"},{"lang":"cn","x_late":"驱动程序 - 系统管理"},{"lang":"tw","x_late":"驅動程式 ─ 系統管理"},{"lang":"de","x_late":"Treiber - Systemverwaltung"},{"lang":"ko","x_late":"드라이버 - 시스템 관리"},{"lang":"it","x_late":"Driver - Gestione sistema"},{"lang":"ja","x_late":"ドライバ - システム マネジメント"},{"lang":"es","x_late":"Controlador - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides the driver for the Microchip/Microsemi PCIe Gen 4 Switch."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"567192","datemodified":"2021-09-07T05:50:57","file_list":["cp049472.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"md5sum":"0ba2d05b822ad01a2b6d70ccbf4fb0aa","name":"cp049472.exe","release":"2021-09-07T05:49:16","revision":"0","sha1sum":"a095e0df2dc32de22f3377eeac7293ace6a4b420","size":"553KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"type_of_change":"1","version":"15.52.13.445"}],"id":{"product":"b75caf763a204707bef1840fcde5be6a","version":"e70f23b97b4e431298d96cb8a5ffe440"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Place the Smart Component in a temporary directory, then double-click it to run.<br />\nSelect &quot;Install&quot; to start extracting to a temporary location on the hard drive.<br />\nClick the &quot;Install&quot; button to perform the driver installation.</p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"100"},"supported_devices":[{"dev":"4000","subdev":"4000","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-400011f84000","type":"pci","ven":"11F8"},{"dev":"4052","subdev":"4052","subven":"11F8","target_guid":"a6b1a447-382a-5a4f-11f8-405211f84052","type":"pci","ven":"11F8"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-07T05:28:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"}],"sw_keys":[{"name":"Switchtec.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3198080","datemodified":"2021-07-26T06:00:31","file_list":["cp048468.xml","cpqsetup.exe","GPM1645ASAD4.rel","payload.json","setup.dll"],"md5sum":"2b95f4eca770346c00d39cc465df9e98","name":"cp048468.exe","release":"2021-07-26T05:53:04","revision":"0","sha1sum":"fa8471a1065f5475b958db8fd715c95c253b8711","size":"3MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"38d3787c49804ab1b404f61b3cd58354","version":"feaec5b8282a4ad787dfe0e69874f5b0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:27:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains drivers for the HPE QLogic FastLinQ 10/25/50 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic FastLinQ 10/25/50 GbEマルチファンクションアダプター用のドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qedf, version 2.2.62.0</li>\n\t<li>qedentv-ens, version 3.11.42.0</li>\n\t<li>qedrntv, version 3.11.40.0</li>\n\t<li>qedentv, version 3.11.41.0</li>\n\t<li>qedi, version 2.19.59.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>この製品には、以下のドライバーが含まれています。</p>\n\n<ul>\n\t<li>qedf、バージョン2.2.62.0</li>\n\t<li>qedentv-ens、バージョン3.11.42.0</li>\n\t<li>qedrntv、バージョン3.11.40.0</li>\n\t<li>qedentv、バージョン3.11.41.0</li>\n\t<li>qedi、バージョン2.19.59.0</li>\n</ul>\n"}],"files":[{"bytes":"6265098","datemodified":"2021-11-24T06:46:21","file_list":["/cp050054.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.11.43.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vib20/qedi/QLC_bootbank_qedi_2.19.70.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vib20/qedentv/QLC_bootbank_qedentv_3.11.45.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vib20/qedf/QLC_bootbank_qedf_2.2.70.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/vib20/qedentv-ens/QLC_bootbank_qedentv-ens_3.11.43.0-1OEM.670.0.0.8169922.vib","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vibs/qedrntv--8282821341203919151.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vibs/qedi--3247979939804523486.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vibs/qedentv-4608052874297387900.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vibs/qedf--7895646733618938570.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/vibs/qedentv-ens--1604898060008421505.xml","/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922-offline_bundle-18563107.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_4.0.278.0-1OEM.670.0.0.8169922.xml"],"md5sum":"019f54d7166b8ebaed0b2553f6f83852","name":"cp050054.zip","release":"2021-11-24T06:42:11","revision":"0","sha1sum":"05d8ca583d0a80b3831fcf61124352825cf7bbb7","size":"5MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5fbcae5e","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"qedrntv","version":"3.11.43.0-1OEM.670.0.0.8169922"},{"name":"qedi","version":"2.19.70.0-1OEM.670.0.0.8169922"},{"name":"qedentv","version":"3.11.45.0-1OEM.670.0.0.8169922"},{"name":"qedf","version":"2.2.70.0-1OEM.670.0.0.8169922"},{"name":"qedentv-ens","version":"3.11.43.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"2f321a74cb604b5798705f3942acaadd","version":"8b4d087222364e5e8f07c582d6f7d798"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"HPE QLogic FastLinQ 10/25/50 GbEマルチファンクションドライバー for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8090159002bd","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-809015900220","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021d","type":"pci","ven":"1077"},{"dev":"8090","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80901590021f","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-24T05:43:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product enhances reliability via adding support for communication between firmware and drivers.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue Vmkernel logs are flooding while running the traffic.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qedentv-ens:3.11.43.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedf:2.2.70.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedi:2.19.70.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedentv:3.11.45.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qedrntv:3.11.43.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD2"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD2"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD2"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD2"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD2"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD2"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCMSssseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、 MO001600JWDLA および MO003200JWDLB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3747760","datemodified":"2021-07-24T05:09:23","file_list":["cp048555.xml","cpqsetup.exe","HBCMSssseFD2.rel","payload.json","setup.dll"],"md5sum":"433342b71b76ab3642fe40b050eafc6f","name":"cp048555.exe","release":"2021-07-24T05:01:05","revision":"0","sha1sum":"b746b0f2c5ba2addd2ab42a7d076ae74e3f6d8b5","size":"3MB","target_guids":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"ae8b95207bc948489c851dd62c16f373","version":"c2d88e486e524711af6f115eb63d5750"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EO000400JWDKP、EO000800JWDKQ、EO001600JWDKR、MO000400JWDKU、MO000800JWDKV、MO001600JWDLA、およびMO003200JWDLBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EO001600JWDKR","target_guid":"452340a5-304f-3130-3630-304a57444b52","type":"sas"},{"id":"MO001600JWDLA","target_guid":"4d2340a5-304f-3130-3630-304a57444c41","type":"sas"},{"id":"MO003200JWDLB","target_guid":"4d2340a5-304f-3330-3230-304a57444c42","type":"sas"},{"id":"EO000400JWDKP","target_guid":"452340a5-304f-3030-3430-304a57444b50","type":"sas"},{"id":"MO000400JWDKU","target_guid":"4d2340a5-304f-3030-3430-304a57444b55","type":"sas"},{"id":"EO000800JWDKQ","target_guid":"452340a5-304f-3030-3830-304a57444b51","type":"sas"},{"id":"MO000800JWDKV","target_guid":"4d2340a5-304f-3030-3830-304a57444b56","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:13:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000400JWDKP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWDLA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JWDKQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWDKU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWDLB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWDKV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWDKR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) ConnectX6アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27981781","datemodified":"2022-02-05T13:58:33","file_list":["/CP050419.vmexe","/CP050419.vmfile","/CP050419.xml","/CP050419_VMw.zip","/payload.json","/README.txt","/CP050419_VMw.zip/index.xml","/CP050419_VMw.zip/vendor-index.xml","/CP050419_VMw.zip/metadata.zip","/CP050419_VMw.zip/vib20/CP050419/HPE_bootbank_CP050419_1.0.3-6.5.0.4240417.vib","/CP050419_VMw.zip/metadata.zip/vendor-index.xml","/CP050419_VMw.zip/metadata.zip/vmware.xml","/CP050419_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050419_1.0.3-6.5.0.4240417.xml","/CP050419_VMw.zip/metadata.zip/vibs/CP050419-5289984006815265769.xml"],"md5sum":"008a52e622b5f64425bcad5551083cf0","name":"CP050419.zip","release":"2022-02-05T17:16:03","revision":"0","sha1sum":"f6c2c825486cb444dbf4b23924f143b997e9ec4f","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050419","version":"1.0.3-6.5.0.4240417"}]}],"id":{"product":"08ec266b2d2d49f5bd28c75479361f16","version":"56a85107d154483faaa4db07eb530f19"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline:</strong> &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX6デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T07:06:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21</p>\n\n<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot.&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n<strong>Additional Fixes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>\n\t<li>Improved PortXmitWait IB counter accuracy.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 20.32.1010:</strong></p>\n\n<ul>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li>\n</ul>\n\n<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. If case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit per-host per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n\t<li>Limited the external loopback speed according to the used module&#39;s capabilities.</li>\n\t<li>Modified the Effective BER calculation method. Due to this, the value of the Effective BER will be slightly higher, however the link quality remains the same as prior to this change.</li>\n\t<li>This firmware version includes the following PCIe changes:\n\t<ul>\n\t\t<li>Fixed the ACS Port Number field in DSPs and ACS Egress Control Vector field in DSPs.</li>\n\t\t<li>Added support for VSC on USP of PCIe Switch.</li>\n\t\t<li>Fixed the mapping of Legacy Interrupts in the PCIe Switch.</li>\n\t\t<li>Fixed MRRS &amp; MPS configurations in DSPs.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>System could not create more than 128K QPs.</li>\n\t<li>Incorrect indication of the PCIe link down in the AER registers on PCIe switch upstream port.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The flash frequency on boot was lower than expected (under 50Mhz). The issue was fixed by enabling the firmware to increase it on boot2 to normal frequency.</li>\n\t<li>A race condition between DC QP flush and DC packets that led to stuck slices in the hardware. To avoid such situation, firmware keeps the TCU drop set until QP flush is done.</li>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains drivers for the HPE Broadcom NX1 1Gb Ethernet Adapters for Microsoft Windows Server 2019 and Windows Server 2022."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"982464","datemodified":"2021-09-16T08:17:18","file_list":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp047793.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"37cf981d6ec62a8dac311c91120a0afb","name":"cp047793.exe","release":"2021-09-16T08:02:46","revision":"0","sha1sum":"699ad917ed71f11ab237d44054662229d8bf8650","size":"959KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"type_of_change":"0","version":"219.0.1.0"}],"id":{"product":"b9a8e50fea15459f9f236f2538fb4a07","version":"3af07b1b16af4e7dbea61e55c812d3a6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"tw","x_late":"將智慧型元件下載至硬碟上的目錄，並變更至該目錄。<p>從該磁碟和目錄，執行下載的檔案。<p>按一下「Install」(安裝) 按鈕，繼續執行安裝程序。"},{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ko","x_late":"스마트 구성 요소를 하드 드라이브의 디렉터리로 다운로드하고 그 디렉터리로 이동합니다.<p>드라이브와 디렉터리에서 다운로드한 파일을 실행합니다.<p>\"설치\" 버튼을 클릭하여 설치 작업을 진행합니다."},{"lang":"cn","x_late":"将 Smart Component 下载到硬盘目录中，然后转至该目录。<p>在该硬盘目录中，执行下载的文件。<p>点击“安装”按钮进行安装。"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスク ドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE Broadcom NX1 1Gbドライバーfor Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product correct an issue which fixes Windows driver causes NMI/RSOD during OS shutdown.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","curr_fixes_x_late":"<p>This product correct an issue which fixes Windows driver causes NMI/RSOD during OS shutdown</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"b57nd60a.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0600JDYTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HKFL4CD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a4459544e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: EH0600JDYTN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH0600JDYTN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EH0600JDYTN Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.&nbsp;</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None.</p>\n"}],"files":[{"bytes":"17533698","datemodified":"2021-08-30T07:19:49","file_list":["/CP048294_BUILD_2.data","/CP048294.vmexe","/CP048294.vmexe64","/CP048294.vmfile","/CP048294_VMw.zip","/CP048294.xml","/payload.json","/CP048294_VMw.zip/index.xml","/CP048294_VMw.zip/vendor-index.xml","/CP048294_VMw.zip/metadata.zip","/CP048294_VMw.zip/vib20/CP048294/HPE_bootbank_CP048294_HPD7.2-7.0.0.15843807.vib","/CP048294_VMw.zip/metadata.zip/vendor-index.xml","/CP048294_VMw.zip/metadata.zip/vmware.xml","/CP048294_VMw.zip/metadata.zip/vibs/CP048294-7789547198463790500.xml","/CP048294_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048294_HPD7.2-7.0.0.15843807.xml"],"md5sum":"cee9e2f669976dbddd5df382bacf1d49","name":"CP048294.zip","release":"2021-08-30T07:14:48","revision":"0","sha1sum":"4e5a0c69aa8e23b800cb25467adaa2ffb4479983","size":"16MB","target_guids":["002340a5-4500-3048-3630-304a4459544e"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP048294","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"ce1fbf38afa940d590b86cded0a4b8a1","version":"7255b73afb334813b61a9ca22df050c5"},"installation":{"command":"CP040688.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EH0600JDYTN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EH0600JDYTNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH0600JDYTN","target_guid":"002340a5-4500-3048-3630-304a4459544e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T08:41:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.ÃÂ </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Fixes a data integrity risk where stale data is mistakenly used from cache.</li>\n\t<li>Fixes a data integrity risk where stale data is returned on an unaligned overlapped write-read operation.</li>\n\t<li>Fixes a data integrity risk during a sequential read and write workload when a recovered error is encountered, which could cause incomplete data to be read.ÃÂ </li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JDYTN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.5 includes the latest Agentless Management Service (AMS), HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, and Fibre Channel(FC) HBA access libraries."},{"lang":"ja","x_late":"HPE ESXi Management Smartコンポーネントfor ESXi 6.5には、最新のAgentless Management Service（AMS）、HPE Integrated Lights-Out（iLO）ドライバー、HPE Compaq ROM Utility（CRU）ドライバー、ファイバーチャネル（FC）HBAアクセスライブラリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6561045","datemodified":"2021-09-11T08:54:08","file_list":["/cp047523.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/index.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vendor-index.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/fc-enablement-650.3.8.0.6-4240417.vib","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/amsd-650.11.8.0.15-1.4240417.vib","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/ilo_650.10.7.5.2-1OEM.650.0.0.4240417.vib","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/cru_650.6.5.10.4-1OEM.650.0.0.4240417.vib","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vendor-index.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vmware.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vibs/ilo-5995240362405261046.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vibs/amsd-1029506352883834413.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vibs/fc-enablement--2881805892426985186.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/vibs/cru-6087260586819000143.xml","/ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.5-bundle-gen10.11.8.0.15-1.zip/bulletins/ams-esxi6.5-bundle-gen10.11.8.0.15-1.xml"],"md5sum":"745241a8955c4382ffe357cda55f0b1e","name":"cp047523.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"1950d55863f4ff300b092f2f09a67c9d3cb23e82","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"fc-enablement","version":"650.3.8.0.6-4240417"},{"name":"amsd","version":"650.11.8.0.15-1.4240417"},{"name":"ilo","version":"650.10.7.5.2-1OEM.650.0.0.4240417"},{"name":"cru","version":"650.6.5.10.4-1OEM.650.0.0.4240417"}]}],"id":{"product":"955509238bc94896999b8a9beb96f9dc","version":"a92f2c86d2764102a5a62c5eb0db82b2"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.5 for Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"HPE Management Bundle Smartコンポーネントfor ESXi 6.5 for Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T22:30:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru:650.6.5.10.4-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"ilo:650.10.7.5.2-1OEM.650.0.0.4240417","sw_key_expectedpath":"driver:vmware:zip"},{"name":"amsd:650.11.8.0.15-1.4240417","sw_key_expectedpath":"software:vmware:zip"},{"name":"fc-enablement:650.3.8.0.6-4240417","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains iSCSI drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Emulex 10/20GbEサーバーアダプター用のiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"892700","datemodified":"2021-01-14T08:29:02","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/be2iscsi","./lib/modules/4.12.14-120-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"1957e512d762d485d15167e516341024","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"44f845ff564809965b476481a94e287f18c82493","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"870976","datemodified":"2021-01-14T08:15:11","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/be2iscsi","./lib/modules/4.12.14-94.41-default/updates/be2iscsi/be2iscsi.ko","./usr/share/smartupdate/be2iscsi-kmp-default/component.xml"],"md5sum":"09216072a0e70cfcbfbe2202bfa800db","name":"be2iscsi-kmp-default-12.0.1342.0_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-01-14T07:55:05","revision":"0","sha1sum":"bb47fb22cf0b2e51bf11aab8289e7e2799a8ab53","size":"850KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecdaa9949b"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"1e813f94062740e78e298970d25a3203","version":"058d8b512c4e4243a6a2850b0e861ad7"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE iSCSI Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE iSCSI ドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 5</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2iscsi-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD4"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD4"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD4"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1645ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"16576186","datemodified":"2021-08-27T13:36:28","file_list":["/CP048454_BUILD_2.data","/CP048454.vmexe","/CP048454.vmexe64","/CP048454.vmfile","/CP048454_VMw.zip","/CP048454.xml","/payload.json","/CP048454_VMw.zip/index.xml","/CP048454_VMw.zip/vendor-index.xml","/CP048454_VMw.zip/metadata.zip","/CP048454_VMw.zip/vib20/CP048454/HPE_bootbank_CP048454_HPD4.2-7.0.0.15843807.vib","/CP048454_VMw.zip/metadata.zip/vendor-index.xml","/CP048454_VMw.zip/metadata.zip/vmware.xml","/CP048454_VMw.zip/metadata.zip/vibs/CP048454--8285572539374706749.xml","/CP048454_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048454_HPD4.2-7.0.0.15843807.xml"],"md5sum":"266e51ea19960813ec2d464af7617e8d","name":"CP048454.zip","release":"2021-08-27T13:29:07","revision":"0","sha1sum":"92e2ae47bb3e13d95051047c9d4686cd8c7fc077","size":"15MB","target_guids":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048454","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"001e7fbaf67f420ebcb746aae6b4aee2","version":"fa3b86e380cb4a2380bb378a90c8e115"},"installation":{"command":"CP040556.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p>             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p> </p>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000800JWZJP、VO001600JWZJQ、VO003200JWZJRおよびVO006400JWZJTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO006400JWZJT","target_guid":"562340a5-304f-3630-3430-304a575a4a54","type":"sas"},{"id":"VO003200JWZJR","target_guid":"562340a5-304f-3330-3230-304a575a4a52","type":"sas"},{"id":"VO001600JWZJQ","target_guid":"562340a5-304f-3130-3630-304a575a4a51","type":"sas"},{"id":"VO000800JWZJP","target_guid":"562340a5-304f-3030-3830-304a575a4a50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T07:34:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000800JWZJP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003200JWZJR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001600JWZJQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO006400JWZJT","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 7.0, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 7.0用lsi-mr3コントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"110138","datemodified":"2021-09-09T08:17:54","file_list":["/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip","/cp049486.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807.vib","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/vibs/lsi-mr3-1377627193146561843.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807_17632848.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.716.03.00-1OEM.700.1.0.15843807.xml"],"md5sum":"49a8df09909cfc13d88ba6d565ce27b2","name":"cp049486.zip","release":"2021-09-09T08:16:47","revision":"0","sha1sum":"2d92d1896e6ebb68975b16e69db63adaafd92716","size":"107KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba","20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"lsi-mr3","version":"7.716.03.00-1OEM.700.1.0.15843807"}]}],"id":{"product":"011fd838183d4fe38c4af2e3f27ece00","version":"2e2246c62c9f4916878cacb32098f1d1"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hpe/swpackages and ./hpesum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li> CD /hpe/swpackages および ./hpesum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller (64-bit) Driver for vSphere 7.0 (Driver Component)"},{"lang":"ja","x_late":"HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラー（64-bit）ドライバーfor vSphere 7.0 (ドライバーコンポーネント)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T11:32:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Initial Build for the MR416i-p, MR216i-a, MR416-a, MR216i-p drivers</strong></p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Initial&nbsp;release for the MR416i-p, MR216i-a, MR416-a, MR216i-p drivers</strong></p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-mr3:7.716.03.00-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-lsi-mr3:7.716.03.00-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000JVYZL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304a56595a4c","Version":"HPD3"},{"DeviceName":"MB2000JVYZN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a56595a4e","Version":"HPD3"},{"DeviceName":"MB3000JVYZP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304a56595a50","Version":"HPD3"},{"DeviceName":"MB4000JVYZQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNSD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a56595a51","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB1000JVYZL、MB2000JVYZN、MB3000JVYZPおよびMB4000JVYZQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"5459421","datemodified":"2021-07-23T06:08:53","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/CP048147.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/SMBPNSD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b85516c7d2-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048147.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048147.scexe"],"md5sum":"cff5c86432022543e133fd40009f636b","name":"firmware-hdd-b85516c7d2-HPD3-6.1.x86_64.rpm","release":"2021-07-23T05:57:05","revision":"0","sha1sum":"2f4f75c0b6d0279c2b2d750b75dda7dc6642282e","size":"5MB","target_guids":["002340a5-4d00-3142-3030-304a56595a4c","002340a5-4d00-3242-3030-304a56595a4e","002340a5-4d00-3342-3030-304a56595a50","002340a5-4d00-3442-3030-304a56595a51"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"94af0b81860b4d31a8cc9f27961f4ea0","version":"c9673cea5256465d8afadf1dc1ecea7d"},"installation":{"command":"CP040343.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB1000JVYZL, MB2000JVYZN, MB3000JVYZP and MB4000JVYZQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB1000JVYZL、MB2000JVYZN、MB3000JVYZP、およびMB4000JVYZQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB1000JVYZL","target_guid":"002340a5-4d00-3142-3030-304a56595a4c","type":"sas"},{"id":"MB2000JVYZN","target_guid":"002340a5-4d00-3242-3030-304a56595a4e","type":"sas"},{"id":"MB3000JVYZP","target_guid":"002340a5-4d00-3342-3030-304a56595a50","type":"sas"},{"id":"MB4000JVYZQ","target_guid":"002340a5-4d00-3442-3030-304a56595a51","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T18:41:51","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB1000JVYZL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JVYZN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB3000JVYZP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JVYZQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWBXQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757425851","Version":"HPG8"},{"DeviceName":"MB008000GWBYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAGLXYG8.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475742594c","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB006000GWBXQ and MB008000GWBYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG6<br />\n<br />\n<strong>Previous Version of Firmware:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>HPG6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"19053837","datemodified":"2021-08-30T20:06:08","file_list":["/CP048328_BUILD_2.data","/CP048328.vmexe","/CP048328.vmexe64","/CP048328.vmfile","/CP048328_VMw.zip","/CP048328.xml","/payload.json","/CP048328_VMw.zip/index.xml","/CP048328_VMw.zip/vendor-index.xml","/CP048328_VMw.zip/metadata.zip","/CP048328_VMw.zip/vib20/CP048328/HPE_bootbank_CP048328_HPG8.2-7.0.0.15843807.vib","/CP048328_VMw.zip/metadata.zip/vendor-index.xml","/CP048328_VMw.zip/metadata.zip/vmware.xml","/CP048328_VMw.zip/metadata.zip/vibs/CP048328-1596044245215242078.xml","/CP048328_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048328_HPG8.2-7.0.0.15843807.xml"],"md5sum":"a526d33745151de91334322009a5bd18","name":"CP048328.zip","release":"2021-08-30T20:00:55","revision":"0","sha1sum":"c4395bd8552f3f7e047053d76f76a997547704c3","size":"18MB","target_guids":["4d2340a5-3042-3630-3030-304757425851","4d2340a5-3042-3830-3030-30475742594c"],"type_of_change":"1","version":"HPG8","vib_list":[{"name":"CP048328","version":"HPG8.2-7.0.0.15843807"}]}],"id":{"product":"f2578af2166847fd869273fa7aa2c430","version":"9608bb4ef682476bb212701d6aa2fde3"},"installation":{"command":"CP040789.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWBXQ and MB008000GWBYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWBXQおよびMB008000GWBYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWBXQ","target_guid":"4d2340a5-3042-3630-3030-304757425851","type":"sata"},{"id":"MB008000GWBYL","target_guid":"4d2340a5-3042-3830-3030-30475742594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T17:57:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWBXQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWBYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component package contains the iavf driver for Intel Ethernet NICs running under Microsoft Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1431792","datemodified":"2021-08-12T04:58:44","file_list":["cp048046.xml","cpqsetup.exe","cp_data.xml","iavf65.cat","iavf65.din","iavf65.inf","iavf65.sys","iavfmsg.dll","install.xml","nicco5.dll","nicdrvr.dll","NicInAVF.dll"],"md5sum":"ae7a3d3edea1da543f93c04bfb760627","name":"cp048046.exe","release":"2021-08-12T04:44:29","revision":"0","sha1sum":"111b1f314bceef257151327e93a824208280534c","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6b976669"],"type_of_change":"0","version":"1.12.9.0"}],"id":{"product":"49293a72024f46b59ade80ad47b20a00","version":"199835fde1824e029cf978d94608a430"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel iavf Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"1889","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-188980860001","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0001","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157180860001","type":"pci","ven":"8086"},{"dev":"154c","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1889","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"},{"dev":"1571","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>​Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE</li>\n\t<li>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"iavf655.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 6.5/6.7 Mellanox mst driver for Mellanox devices"},{"lang":"ja","x_late":"VMware ESXi 6.5/6.7 Mellanox mstドライバー for Mellanoxデバイス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"27995","datemodified":"2022-01-28T05:21:52","file_list":["/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip","/cp050399.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/MEL_bootbank_nmst_4.12.0.105-1OEM.650.0.0.4598673.vib","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vendor-index.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vmware.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/vibs/nmst--7851970169650426567.xml","/MLNX-NMST-ESX-6.5.0-4.12.0.105.zip/metadata.zip/bulletins/MLNX-NMST-ESX-4.12.0.105.xml"],"md5sum":"eb714d7394d94bd8ef6837a6c38b0ef2","name":"cp050399.zip","release":"2022-01-28T05:21:05","revision":"0","sha1sum":"dd65183ce942ab8a2453fe9a2cc3191d3b1a2f6d","size":"27KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.12.0.105-1OEM.650.0.0.4598673"}]}],"id":{"product":"60580eadc28e490db38d80ac26f5a3b8","version":"2b9cbb163709402f905a169a5a9c8b40"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 6.5 and 6.7"},{"lang":"ja","x_late":"net-mstカーネルモジュールドライバーコンポーネント for VMware ESXi 6.5および6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T12:30:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for the following adapters:</p>\n\n<ul>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter&nbsp;(Part Number: P21930-B21)</li>\n\t<li>HPE Ethernet 10Gb 2-port SFP+ MCX4621A-ACAB OCP3 Adapter (Part Number: P11341-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter (Part Number: P13188-B21)</li>\n\t<li>HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter (Part Number: P10112-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter (Part Number: P21927-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06154-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (Part Number: P06250-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (Part Number: P06251-B21)</li>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port MCX653105A-HDAT QSFP56 x16 Adapter (Part Number: P23664-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port MCX653105A-ECAT QSFP56 x16 Adapter (Part Number: P23665-B21)</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port MCX653106A-ECAT QSFP56 x16 Adapter (Part Number: P23666-B21)</li>\n\t<li>HPE Ethernet 100Gb 2-Port QSFP56 MCX623106AS-CDAT Adapter (Part Number: P25960-B21)</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>NMST version&nbsp;4.12.0.105:</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for firmware update on all latest Mellanox adapters including ConnectX6, ConnectX6-Dx and ConnectX6-Lx chipsets based adapters.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"nmst:4.12.0.105-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i350 Gigabit Ethernet NICs running under Microsoft Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Microsoft Windows Server 2019で動作しているIntel i350 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1073776","datemodified":"2021-08-12T06:01:21","file_list":["cp047042.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"md5sum":"cd0e49cc54afc385c972062d7f43be5c","name":"cp047042.exe","release":"2021-08-12T05:46:04","revision":"0","sha1sum":"ecd666febeb547317b2f3d7e6aab9eb65f505250","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"type_of_change":"0","version":"12.18.12.1"}],"id":{"product":"5413adceb7d241de900274e399d9c777","version":"02fe4574acd4471fbf634950cea2353e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i350 Driver for Windows Server 2019"},{"lang":"ja","x_late":"Intel i350ドライバー for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1521","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a1","type":"pci","ven":"8086"},{"dev":"1521","subdev":"00A3","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1521808600a3","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1521","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInE1R.dll and e1rmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"e1r68x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C8020","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 10Gb 2-port 546SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C801F","Version":"2.42.5044"},{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1010"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox Ethernet only adapter firmware on Windows Operating Systems."},{"lang":"ja","x_late":"このパッケージは、Windowsオペレーティングシステム上でHPE Mellanox Ethernetアダプター専用のファームウェアをアップグレードするためのユーティリティとバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546SFP+ Adapter (779793-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_1200111023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (779799-B21)</td>\n\t\t\t<td>2.42.5044</td>\n\t\t\t<td>HP_2240110004</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (817749-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2690110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 25Gb 2-port 640SFP28 Adapter (817753-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HP_2420110034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 100Gb 1-port 842QSFP28 Adapter&nbsp;(874253-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000014</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"21914176","datemodified":"2022-02-07T09:46:11","file_list":["cp050367.xml","cpqsetup.exe","fw-ConnectX3Pro-full-rel-2_42_5044-779793-B21_0A-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX3Pro-full-rel-2_42_5044-779799-B21_Ax-CLP-8025-UEFI-14.11.48-FlexBoot-3.4.754.bin","fw-ConnectX4Lx-rel-14_32_1010-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1010-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_32_1010-874253-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"1ea23de2b93e15eddb33a7e3ebfb53c3","name":"cp050367.exe","release":"2022-02-07T09:44:48","revision":"0","sha1sum":"a3b008053ebaef019853f82241a8d626255861a8","size":"20MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C8020","a6b1a447-382a-5a4f-15B3-1007103C801F","a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"type_of_change":"1","version":"1.0.0.16"}],"id":{"product":"00184010ed0a41829836f7c60269273f","version":"f1faf0f79cdd43cfb56a03c6c9f6ed3e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.\n<p>\n From that drive and directory, execute the downloaded file.</p>\n<p>\n Click the Install button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。\n<p>\n そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n<p>\n インストールボタンをクリックして、インストールを開始してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Windows x64) for HPE Mellanox Ethernetアダプター専用"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-08T10:56:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5044 :</strong></p>\n\n<p>&nbsp; &nbsp;779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)<br />\n&nbsp; &nbsp;779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong></p>\n\n<p>&nbsp; &nbsp;817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following devices are updated to 14.31.1200:</strong><br />\n&nbsp; &nbsp;817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</p>\n\n<p><strong>Firmware for the following device is updated to 16.31.1014:</strong></p>\n\n<p>&nbsp; &nbsp;874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</p>\n\n<p><br />\n<strong>New features and changes in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>NVconfig per Port for a Specific Finisar Module: Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override).<br />\n\t<strong>Note:</strong>&nbsp;If the port does not go up, switch to Force mode.&nbsp;</li>\n</ul>\n\n<p><strong>New features and changes in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Added support for Enabling/Disabling NIC and RDMA (port/partition) via the UEFI HII system settings.<br />\n\t<strong>Note:</strong>&nbsp;Values set in this option only take effect when is Ethernet mode.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration:&nbsp;This feature allows the device to be configured with a different number of MSIX<br />\n\tvectors per physical PCI functions.<br />\n\tTo use this feature, please follow these steps:\n\t<ul>\n\t\t<li>​​​​Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>Support for RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>A new bit (&quot;data_in_order&quot;) was added to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.<br />\n\tPages are returned by the driver to the kernel without issuing the MANAGE_PAGES commands to the firmare.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and<br />\n\tthe DQPN.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes&nbsp;included in&nbsp; firmware version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1200:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>779799-B21 (HPE Ethernet 10G 2-port 546FLR-SFP+ Adapter)</li>\n\t<li>779793-B21 (HPE Ethernet 10G 2-port 546SFP+ Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>817749-B21 (HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter)</li>\n\t<li>817753-B21 (HPE Ethernet 25Gb 2-port 640SFP28 Adapter)</li>\n</ul>\n\n<p><strong>Firmware for the following device has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>874253-B21 (HPE Ethernet 100Gb 1-port 842QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n\n<p>.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 2.42.5044 :</strong></p>\n\n<ul>\n\t<li>An issue that prevented the firmware from detecting a link_down event thus preventing the IB bond interface from going to a failover mode.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>The following issues have been fixed in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"","value":"HPE ProLiant SL4500 Chassis"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_NIC","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 驅動程式。"},{"lang":"en","x_late":"This product contains the drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"201543","datemodified":"2021-11-03T12:22:12","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/05","./usr/lib/.build-id/05/b37531902e2dd6fe2f04446ee3f8929eedac1e","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"9107a68a9eba8cd5d8a15d6c4afefd97","name":"kmod-hp-ixgbe-5.13.4-1.rhel7u8.x86_64.rpm","release":"2021-11-03T12:09:51","revision":"0","sha1sum":"bfdff8536180f4c3add62abf9bcdd1d9105c9f8e","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.13.4-1"},{"bytes":"201543","datemodified":"2021-11-03T12:23:27","file_list":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/b586a85b2ba5454189f72304bf82070dd14cb5","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"md5sum":"a966d8f6ba8d8acb7a783c2b667daca9","name":"kmod-hp-ixgbe-5.13.4-1.rhel7u9.x86_64.rpm","release":"2021-11-03T12:09:51","revision":"0","sha1sum":"e12002e51a1164118ff76400d48a314efc162dcc","size":"196KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"type_of_change":"0","version":"5.13.4-1"}],"id":{"product":"e2ded6c100dc4bec88c153fd9c85c964","version":"f8a62e63ea014e7b8ae2096c803f2ac9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbe 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbe 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbeドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product is particular for&nbsp;Red Hat Enterprise Linux 7 Update 8 patched kernel version 3.10.0-1127.10.1 or later.</p>\n","latest_fixes_x_late":"<p>This product corrects an issue where the patched kernel symbol changed on PTP (Precision Time Protocol) module.</p>\n\n<p>&nbsp;</p>\n"},{"curr_enhancements_x_late":"<p>This products enhances the mechanism that enable MDD(Malicious Driver Detection) when SRIOV is disabled.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbe","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1692270","datemodified":"2021-11-02T16:21:41","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipath.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_mthca.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_qib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb3.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_nes.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ocrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ipath/ib_ipath.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/3.10.0-1160.el7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"b890ac13bd4f82d8d3bded0831431337","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel7u9.x86_64.rpm","release":"2021-11-02T15:00:15","revision":"0","sha1sum":"6d8deddf52a024520ddd27363bccbaadbe9123cd","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"2255886","datemodified":"2021-11-02T16:25:56","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/AUTHORS","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/COPYING","./usr/share/doc/libibumad-43.1.1.MLNX20200211.078947f/ChangeLog","./usr/share/doc/libibverbs-41mlnx1","./usr/share/doc/libibverbs-41mlnx1/AUTHORS","./usr/share/doc/libibverbs-41mlnx1/COPYING","./usr/share/doc/libibverbs-41mlnx1/ChangeLog","./usr/share/doc/libibverbs-41mlnx1/README","./usr/share/doc/libmlx4-41mlnx1","./usr/share/doc/libmlx4-41mlnx1/AUTHORS","./usr/share/doc/libmlx4-41mlnx1/COPYING","./usr/share/doc/libmlx4-41mlnx1/README","./usr/share/doc/libmlx5-41mlnx1","./usr/share/doc/libmlx5-41mlnx1/AUTHORS","./usr/share/doc/libmlx5-41mlnx1/COPYING","./usr/share/doc/libmlx5-41mlnx1/README","./usr/share/doc/librdmacm-41mlnx1","./usr/share/doc/librdmacm-41mlnx1/AUTHORS","./usr/share/doc/librdmacm-41mlnx1/COPYING","./usr/share/doc/librdmacm-41mlnx1/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo"],"md5sum":"cb00ad0364e0975e811e82652f35af2b","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel7u9.x86_64.rpm","release":"2021-11-02T15:00:15","revision":"0","sha1sum":"5123f20197768ab6f6ae7c3ee325331d7d82db84","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"408f4a25d4b44e79916ac17904fc2648","version":"7e2475b8ebc64815826de650dc50fe51"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 3.10.0-1160.el7.x86_64&nbsp;or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"},{"lang":"ja","x_late":"<p>rootとしてログインし、rpmをご使用のハードディスク上のディレクトリにダウンロードし、そのディレクトリに移動します。<br />\n<br />\n<strong>注記</strong>：RoCEのユーザースペース機能を有効にするために、使用されているカーネルバージョンやタイプにかかわらず、\"mlnx-ofa_kernel-4.9\" RPMをインストールする必要があります。RoCEのユーザースペースライブラリであるRPM（mlnx-ofa_kernel）はOS配布に含まれるOpenMPI RPMと競合することがあります。これは既知の挙動です。Linux分布からのOpenMPI RPMは\"mlnx-ofa_kernel\"のインストレーションの前にはターゲットのノードにインストールされないことに注意が必要です。もし既にインストールされていれば、 HPE Mellanox RoCEのドライバーパッケージをインストールする前にすべてのOpenMPI配布のRPMをアンインストールしてください。 <br />\n<br />\nドライバーをインストールまたはアップグレードするには次のようにします。<br />\nカーネルバージョン3.10.0-1160.el7.x86_64または将来のerrataを使用している場合：<br />\n<br />\n<strong># rpm -Uvh kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel7u9.x86_64.rpm</strong><br />\n<br />\nセットアップは完了しました。ドライバーを有効にするにはコンピューターを再起動します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 7 Update 9 (x86_64)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet)ドライバー for Red Hat Enterprise Linux 7 Update 9 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes.\n\n"},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM3ストレージバックプレーンをアップデートします。\n\n"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2227048","datemodified":"2022-01-17T14:49:47","file_list":["cp050753.xml","cpqsetup.exe","payload.json","setup.dll","UBM3_V1.24.hex.fw"],"md5sum":"8c28cee5bf6d829e80acefa7a1f932de","name":"cp050753.exe","release":"2022-01-17T14:36:28","revision":"0","sha1sum":"f29793979bc200ba1bb4339616359c3c94f0abda","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.24"}],"id":{"product":"a49dd08da845410cb98aa24a3deb45b2","version":"3918dddbb4b148989aaf56f1351b86fc"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for Windows x64 - Gen10Plus UBM3 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor Windows x64 - Gen10Plus UBM3 バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"2048"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:34:53","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows 2022 to supported OS</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB001000GWJAN、MB002000GWFWA および MB004000GWFWB ドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16951781","datemodified":"2021-08-30T19:01:51","file_list":["/CP048313_BUILD_3.data","/CP048313.vmexe","/CP048313.vmexe64","/CP048313.vmfile","/CP048313_VMw.zip","/CP048313.xml","/payload.json","/CP048313_VMw.zip/index.xml","/CP048313_VMw.zip/vendor-index.xml","/CP048313_VMw.zip/metadata.zip","/CP048313_VMw.zip/vib20/CP048313/HPE_bootbank_CP048313_HPG1.3-7.0.0.15843807.vib","/CP048313_VMw.zip/metadata.zip/vendor-index.xml","/CP048313_VMw.zip/metadata.zip/vmware.xml","/CP048313_VMw.zip/metadata.zip/vibs/CP048313--3087150825584867912.xml","/CP048313_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048313_HPG1.3-7.0.0.15843807.xml"],"md5sum":"73c08e34413d771ebfc190c1d2f53d56","name":"CP048313.zip","release":"2021-08-30T18:56:52","revision":"0","sha1sum":"b12b7f34bc0e6554134ea1bf4696a7e3407fd80e","size":"16MB","target_guids":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048313","version":"HPG1.3-7.0.0.15843807"}]}],"id":{"product":"0f2b8614c6ab40aea6c15cd633ff1402","version":"c264bb9434d44d469246a2527f3bdf82"},"installation":{"command":"CP040691.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB001000GWJAN、MB002000GWFWAおよびMB004000GWFWBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000GWFWB","target_guid":"4d2340a5-3042-3430-3030-304757465742","type":"sata"},{"id":"MB002000GWFWA","target_guid":"4d2340a5-3042-3230-3030-304757465741","type":"sata"},{"id":"MB001000GWJAN","target_guid":"4d2340a5-3042-3130-3030-3047574a414e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T05:32:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000GWFWB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB001000GWJAN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB002000GWFWA","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1345.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"29517379","datemodified":"2021-08-27T05:48:32","file_list":["./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/.setup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/CP046756.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/brcmflashStandalone-linux-12.0.1345.0-1.zip","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/firmware","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/firmware/oc14-12.0.1345.0.ufi","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/payload.json","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-cna-mezz-emulex-2021.10.01-1.8/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046756.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046756.scexe"],"md5sum":"c4ea36e830f2113a39489e0e22bcb08e","name":"firmware-cna-mezz-emulex-2021.10.01-1.8.x86_64.rpm","release":"2021-08-27T05:35:11","revision":"0","sha1sum":"c3247a424bf12e53fa334fa5ca55082e278d5e85","size":"28MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"e408d6e3ab3141509209d893c046e5e7","version":"47e884be97a341babcfe5438e8fc339b"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uhv &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems)&nbsp;</p>\n\n<p>&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./.setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command: rpm -e &lt;rpm_package_name&gt;.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.<br />\n<br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">We&nbsp;have separate components to update fibre channel and converged network adapters.&nbsp; This is a converged network adapter update component.</p>\n\n<p dir=\"LTR\">This component is only supported on RHEL7u8, RHEL7u9, RHEL8u3, SLES12SP5, SLES15SP2 OS&#39;s.</p>\n\n<p dir=\"LTR\"><br />\nUpdated CNA (XE100 series) firmware&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050853.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.04.400"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2630720","datemodified":"2022-01-26T05:57:55","file_list":["cp050853.compsig","cp050853.zip","cp050857.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"46c6fe2839e7360974eb4e1926a93d06","name":"cp050857.exe","release":"2022-01-26T05:56:45","revision":"0","sha1sum":"9cc5a12f3b143f125b6783c3986659263830fd0c","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-a3601590028d"],"type_of_change":"0","version":"05.01.04.400"}],"id":{"product":"d9b51eadf7e440fc88f26963aec59690","version":"a2f89383987d4cb083a1ef09f2d87e03"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download cp047666.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cp047666.exe.&nbsp;<br />\n2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>Execute the file cp047666.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p><strong>HPE SHA256 Authenticodeデジタル署名を検証するには、次の手順に従います。</strong><br />\n1.    cp047666.exeを、サポートされているバージョンのMicrosoft Windows Server OSを実行しているシステムにダウンロードします。このファイルをダウンロードすることにより、[ライセンス]フィールドに一覧表示されているHPE License Agreement v1.pdfのライセンス条項に同意することになります。<br />\n2.    ファイル名を右クリックして、プロパティを選択します。<br />\n3.    プロパティウィンドウが表示されたら、デジタル署名タブをクリックします。<br />\n4.    署名リストの最初のエントリーを選択し、詳細ボタンをクリックします。 <br />\n5.    署名ステータスは、詳細ダイアログの上部に表示されます。<br />\n6.    署名メッセージに\"このデジタル署名は問題ありません。\"と表示されている場合、ファームウェアパッケージはHPEパッケージとして認証されています<br />\n7.    \"このデジタル署名には問題があります。\"というメッセージが表示されている場合は、次の手順を実行します。<br />\n        a.    ファームウェアを展開しないでください。<br />\n        b.    ファイルをもう一度ダウンロードし、署名をもう一度確認します。署名に問題がある場合は、HPEテクニカルサポートにお問い合わせください。 </p>\n\n<p><br />\n<strong>SHA256ハッシュ値を検証するには、以下の手順に従ってください。</strong><br />\n1.    Microsoft Windows CRC/SHAツールを使用して、cp047666.exeのSHA256ハッシュ値を計算します。 <br />\n2.    計算された値を、HPEサポートセンターのダウンロードページのインストール手順タブに表示されるSHA256値と比較します。<br />\n•    値が一致する場合、ダウンロードしたファイルの整合性は検証済みです。<br />\n•    値が一致しない場合は、ファイルやその内容を展開しないでください。<br />\n•    ファイルをもう一度ダウンロードし、新しいハッシュ値を比較します。 <br />\n•    ハッシュ値が一致しない場合は、ダウンロードしたファイルを展開せず、HPEテクニカルサポートに連絡してください。</p>\n\n<p>cp047666.exeファイルを実行し、画面の指示に従ってインストールを完了してください。<br />\nドライバーのインストールが完了した後、サーバーを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - Server Platform Services（SPS）ファームウェア for HPE MicroServer Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-24T16:01:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"See the release document in Download Product Binaries page from Product Summary of the firmware product.","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2020-24509. These security vulnerabilities are documented in Intel Security Advisory INTEL-SA-00459.&nbsp; These issues are not unique to HPE servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Important Notes:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Firmware Dependencies:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Problems Fixed:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">This revision of the Server Platform Services (SPS) Firmware provides mitigations for SPS security vulnerabilities documented as CVE-2021-0060. This issue is not unique to HPE servers.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\"><strong>Known Issues:</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:start\">None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"SPS_UEFI_Gen10Plus","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 SUSE Linux Enterprise Server 12 x86_64 下執行的 HPE Intel i40e 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel i40e Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ko","x_late":"이 제품에는 SUSE Linux Enterprise Server 12 x86_64에서 실행되는 HPE Intel i40e 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在SUSE Linux Enterprise Server 12 x86_64下运行的HPE Intel i40e以太网网卡SRIOV虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE Intel i40e Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1541916","datemodified":"2021-08-24T17:13:18","file_list":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-iavf","./lib/modules/4.12.14-120-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"md5sum":"38c57191d49b37b0bf32e93aa45eae69","name":"hp-iavf-kmp-default-4.2.7_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-08-24T17:05:06","revision":"0","sha1sum":"b2e97f1f4e162476f079675a18cee6aafb210212","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"type_of_change":"0","version":"4.2.7-1"}],"id":{"product":"e05dec268daa4148be358b19a3214eed","version":"8967d5dabe0e420cadc4b87bffd0d992"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"HPE Intel iavfドライバー for SUSE Linux Enterprise Server 12 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"37CE","subdev":"0215","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37ce15900215","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0216","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900216","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0247","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900247","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FC","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fc","type":"pci","ven":"8086"},{"dev":"1572","subdev":"22FD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1572103c22fd","type":"pci","ven":"8086"},{"dev":"37D3","subdev":"0219","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d315900219","type":"pci","ven":"8086"},{"dev":"37D2","subdev":"0218","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d215900218","type":"pci","ven":"8086"},{"dev":"37D1","subdev":"0217","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-37d115900217","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"},{"dev":"1581","subdev":"00F8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1581159000f8","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul style=\"list-style-type:square\">\n\t<li>This product now supports the following servers:</li>\n</ul>\n\n<p style=\"margin-left:80px; margin-right:0px; text-align:left\">&nbsp;HPE Superdome Flex 280 &nbsp;<br />\n&nbsp;HPE Superdome Flex Server &nbsp;<br />\n&nbsp;HPE Superdome Flex 2&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where HyperV Ping is lost after change MTU on VF interface in a VM linux</li>\n\t<li>This product addresses an issue which could lead to traffic interrupts and full traffic stop through the bond when VFs were added to bonding-alb/tlb modes</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"hp-iavf-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"3947472","datemodified":"2021-07-25T20:53:18","file_list":["cp048653.xml","cpqsetup.exe","payload.json","SCIMARRNNSD6.rel","setup.dll"],"md5sum":"cfa1e1f12d58dc18a940b79be82cc193","name":"cp048653.exe","release":"2021-07-25T20:46:07","revision":"0","sha1sum":"f9d481bd6ce962107c7d96a05cd242a3a60f2c1d","size":"3MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"eb650e36c9b84eb1b7c6c75d7ff3e9f2","version":"4031b272f4a0478a98c57758723116b8"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows (x64) - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T19:01:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component contains version 9.4.5.20 of the QLogic Storport driver which provides Mezzanine Fibre Channel Host Bus Adapter driver support for HPE storage arrays."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1613704","datemodified":"2021-08-27T05:26:25","file_list":["cp046783.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"md5sum":"4ac04930c4fea06bf3f788bf43c022cd","name":"cp046783.exe","release":"2021-08-27T05:23:55","revision":"0","sha1sum":"042e1e749d1b7c4276a93732326d3d8584a0cb91","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"type_of_change":"1","version":"9.4.5.20"}],"id":{"product":"95f513b0af8c485bb6224e1108f86d03","version":"e10a18dab96a4cf7babe46f7fa3b29af"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.<br />\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Mezzanine Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"2031","subdev":"1939","subven":"103C","target_guid":"a6b1a447-382a-5a4f-1077-2031103c1939","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:28:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.2.20</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior where Input/Output (I/O) incompletions would be reported after extended periods of uptime in an Fibre Channel (FC) fabric doing Remote Desktop Protocol (RDP) requests</li>\n\t<li>Fixed a behavior where Multipath I/O (MPIO) paths may not recover if left offline for more than 90 seconds&nbsp;&nbsp;&nbsp;</li>\n\t<li>Fixed a behavior where an Fibre Channel (FC) Tape device configured for Target Persistent Binding would not be recognized after server reboot</li>\n\t<li>Fixed a behavior where Hyper-V Virtual Machines (VMs) may not see all paths to Logical Unit Numbers (LUNs)</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Made improvements to the Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) Congestion Management algorithms.</li>\n</ul>\n\n<p>Updated&nbsp;to&nbsp;version&nbsp;9.4.5.20</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Removed the &quot;fwload&quot; registry parameter.</li>\n\t<li>Fixed an unwanted behavior where Link up/down messages were not always logged in the Window System Event log.</li>\n\t<li>Fixed unwanted behavior with the reporting of Fabric Port Identification Number (FPIN) and Universal Storage Area Network (SAN) Congestion Mitigation (USCM) statistics.</li>\n\t<li>Fixed an unwanted behavior where connections to tape drives may fail to recover in the event of &quot;SCSI Check Condition&quot; commands or cable pulls.</li>\n\t<li>Fixed an unwanted behavior where the server may encounter a Blue Screen Of Death (BSOD) 0x0000009f message during shutdown as described in <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00116202en_us\">Advisory: HPE Host Bus Adapters - HPE Platforms Running a Microsoft Windows Server 2016 / 2019 Hyper-V Environment, and Configured With Certain HPE HBAs With the QLogic Storport Driver v9.4.2.20, May Experience a Bug Check 0x9F Event</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"ql2300.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"","Devices":{"Device":[]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900217","languages":[{"lang":"fr","x_late":"Micrologiciel - Infrastructure Blade"},{"lang":"en","x_late":"Firmware - Blade Infrastructure"},{"lang":"cn","x_late":"固件 - 刀片式架构"},{"lang":"tw","x_late":"韌體 ─ 刀鋒型基礎架構"},{"lang":"de","x_late":"Firmware - Blade-Infrastruktur"},{"lang":"ko","x_late":"펌웨어 - 블레이드 인프라"},{"lang":"it","x_late":"Firmware - Infrastruttura Blade"},{"lang":"ja","x_late":"ファームウェア - ブレード インフラストラクチャ"},{"lang":"es","x_late":"Firmware - Infraestructura Blade"}]}],"description":[{"lang":"tw","x_late":"此元件包含 HPE BladeSystem c-Class Onboard Administrator 的韌體映像。此韌體提供 HPE BladeSystem c-Class Enclosure 的管理功能。此元件及其韌體可用於下列情況： 1) 作為可以為 Onboard Administrator 韌體的部署而編寫指令碼的獨立元件，2) 在和可以在 Smart Update 韌體 DVD 上找到的 HP Smart Update Manager 一起使用時，此元件可以用於部署韌體至 HP BladeSystem c-Class Onboard Administrator，以及 3) 從該元件解壓縮的韌體可使用 HP BladeSystem c-Class Onboard Administrator 的網路型使用者介面來部署。"},{"lang":"en","x_late":"This component contains the firmware image for HPE BladeSystem c-Class Onboard Administrator. This firmware provides management capabilities for the HPE BladeSystem c-Class Enclosure. This component and its firmware can be used in the following scenarios: 1) as a stand alone component that can be used to script the deployment of the Onboard Administrator firmware, 2) in conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator, and 3) firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator."},{"lang":"ko","x_late":"이 구성 요소에는 HPE BladeSystem c-Class Onboard Administrator의 펌웨어 이미지가 포함되어 있습니다. 이 펌웨어는 HPE BladeSystem c-Class Enclosure에 대한 관리 기능을 제공합니다. 해당 구성요소와 펌웨어는 다음과 같은 상황에서 사용할 수 있습니다. 1) 독립형 구성 요소로서 Onboard Administrator 펌웨어의 배포 스크립트에 사용될 수 있습니다 2) 스마트 업데이트 펌웨어 DVD에 포함되어 있는 HP Smart Update Manager와 함께 구성요소를 사용하여 HP BladeSystem c-Class Onboard Administrator로 펌웨어를 배포할 수 있습니다 3) HP BladeSystem c-Class Onboard Administrator용 웹 기반 사용자 인터페이스를 사용하여 구성 요소에서 추출된 펌웨어를 배포할 수 있습니다."},{"lang":"cn","x_late":"该组件包含适用于 HPE BladeSystem c-Class Onboard Administrator 的固件映像。该固件可为 HPE BladeSystem c-Class 机箱提供管理功能。该组件及其固件适用于以下情形： 1) 作为可用于编写 Onboard Administrator 固件的部署脚本的独立组件，2) 与 HPE Smart Update Firmware DVD 中的 HP Smart Update Manager 共同使用，此组件可用于将固件部署至 HPE BladeSystem c-Class Onboard Administrator，以及 3) 可使用 HPE BladeSystem c-Class Onboard Administrator 的基于 WEB 的用户界面来部署从该组件中提取的固件。"},{"lang":"ja","x_late":"このコンポーネントには、HPE BladeSystem c-Class Onboard Administratorのファームウェアイメージが含まれています。このファームウェアは、HPE BladeSystem c-Classエンクロージャーの管理機能を提供します。このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます。1) Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント 2) HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上のHPE Smart Update Managerと共同でコンポーネントを使用する 3) コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用してインストールする"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name</strong></p>\n\n<p>HPE BladeSystem c-Class OA Firmware</p>\n\n<p><strong>Release Version</strong></p>\n\n<p>Version 4.97</p>\n\n<p><strong>Previous Version of Firmware</strong></p>\n\n<p>Version 4.96</p>\n\n<p><strong>Firmware Dependency</strong></p>\n\n<p>For firmware compatibility information,see the&nbsp;<em>HPEService Pack for ProLiant Information Library</em>at:<br />\n<a href=\"https://www.hpe.com/servers/spp/documentation\">https://www.hpe.com/servers/spp/documentation</a></p>\n\n<p><strong>Important Notes</strong></p>\n\n<ul>\n\t<li><strong>Firmware Upgrade</strong></li>\n</ul>\n\n<p>Starting OA 4.50 release, a standardized code signing and validation mechanism has been introduced to enhance the firmware image authenticity.</p>\n\n<p>For customers using Firmware ROM image to upgrade OA:</p>\n\n<p>For OA with firmware version less than 3.50, first update to OA 3.50 and then continue updating to OA 4.50 or above.</p>\n\n<p>For customers using Smart Components to upgrade OA:</p>\n\n<p>OA firmware update mechanisms which rely on HPE Smart Components (example: EFM), will not be affected by this change. The Smart Component will automatically perform the intermediate upgrade to OA 3.50 before performing the OA 4.50 or above upgrade.</p>\n\n<ul>\n\t<li><strong>Flash Disaster Recovery</strong></li>\n</ul>\n\n<p>Flash Disaster Recovery to a version of firmware 4.50 or above issupported. The behavior is seen due to the implementation of a new firmware image signing mechanism in OA firmware version 4.50 and above, which causes the FDR mechanism to see the firmware image as an invalid image.</p>\n\n<p>The workaround for this is to use Flash Disaster Recovery procedure to recover to a version of firmware prior to 4.50 and then do a firmware upgrade to the intended version (4.50 or later).</p>\n\n<ul>\n\t<li><strong>EFM</strong></li>\n</ul>\n\n<p>The OA only supports SPP ISO images that are less than 4GB in size, whether hosted directly via the Enclosure DVD feature or an attached USB key, or mounted remotely via a specified URL. If an ISO image exceeds 4 GB, the CLI SHOW FIRMWARE MANAGEMENT command displays ISO URL Status as &ldquo;Invalid URL.&rdquo;<br />\n<br />\nIf an SPP ISO image exceeds 4 GB, it is necessary to create a custom ISO image that excludes components unnecessary to the OA EFM blade firmware update process.&nbsp; At a minimum, the custom ISO must contain the firmware components for HPE ProLiant BL servers. (When using HPE SUM to create the custom ISO image, select Firmware as the Component Type, and select HPE ProLiant BL Series as the Server Type.)&nbsp; For information about creating a custom ISO image compatible for OA EFM functionality, see the&nbsp;<em>HPE BladeSystem Onboard Administrator User Guide</em>. More HPE SUM information can be found via HPE Smart Update Manager online help or at the HPE Smart Update Enterprise Information Library (<a href=\"http://www.hpe.com/info/hpsum/documentation\">http://www.hpe.com/info/hpsum/documentation</a>).</p>\n\n<ul>\n\t<li><strong>FIPS</strong></li>\n</ul>\n\n<p>Onboard Administrator 4.71 is FIPS certified as referenced in the 140-2 In Process list located at <a href=\"http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf\">http://csrc.nist.gov/groups/STM/cmvp/documents/140-1/140InProcess.pdf</a>.</p>\n\n<ul>\n\t<li><strong>IPv6</strong></li>\n</ul>\n\n<p>When the Enable DHCPv6, Enable Router Advertisements, or Enable SLAAC enclosure IPv6 settings are disabled on the Onboard Administrator, the respective DHCPv6 or SLAAC addresses of the iLOs in the enclosure are retained until these addresses expire automatically based on their respective configurations.&nbsp; A manual reset of the iLO releases these addresses immediately.</p>\n"}],"files":[{"bytes":"31530472","datemodified":"2021-01-28T15:23:34","file_list":["archives/","archives/hpoa350.bin","cp046217.xml","cp_data.xml","oa497.bin","oaupgrade.exe"],"md5sum":"846c6f4a9c96f5d7fa920fc4783acc15","name":"cp046217.exe","release":"2021-01-28T15:19:06","revision":"0","sha1sum":"8290f2d8103f5c74631967a529bfdc8f0d174ad9","size":"30MB","target_guids":[],"type_of_change":"1","version":"4.97"}],"id":{"product":"771e2c2febad408da9107df2836d8e4d","version":"70086c3a4faf40419d579e87c25c79aa"},"installation":{"command":"oaupgrade.exe","command_params":"oa497.bin","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":500,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>This component and its firmware can be used in the following scenarios:</strong></p>\n\n<ol>\n\t<li>As a stand alone component that can be used to script the deployment of the Onboard Administrator firmware</li>\n\t<li>In conjunction with the HPE Smart Update Manager found on the Smart Update Firmware DVD, the component can be used to deploy the firmware to the HPE BladeSystem c-Class Onboard Administrator</li>\n\t<li>Firmware extracted from the component can be deployed using the web-based user interface for the HPE BladeSystem c-Class Onboard Administrator</li>\n</ol>\n\n<p><strong>Installation Notes for using the component as a stand alone component</strong></p>\n\n<p>This smart component is a self-extracting executable. The smart component unpacks itself, flashes the firmware on the HPE BladeSystem c-Class Onboard Administrator, and cleans up.</p>\n\n<p>The general command line syntax for this smart component is</p>\n\n<p><br />\n&nbsp;&nbsp;&nbsp;cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</p>\n\n<p><br />\nwhere cpxxxxxx.exe represents the filename of the component</p>\n\n<p>NOTE: All arguments and information enclosed in brackets are optional. If required arguments are not included on the command line, you will be prompted to provide the input.</p>\n\n<ul dir=\"ltr\">\n\t<li>&nbsp;/target &lt;netAddress&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The netAddress parameter is the IP address or DNS name of the OA to target.&nbsp; This should be the Active OA if two OA&rsquo;s are in an enclosure.&nbsp; There is a space between the /target and the netAddress parameter.</li>\n\t<li>&nbsp;/user &lt;username&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;The username is the userid to use when attempting to login to the OA.&nbsp; There is a space between the /user and the username parameter.</li>\n\t<li>&nbsp;/passwd &lt;password&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp; &nbsp;&nbsp;&nbsp;The password is the password for the userid to login to the OA.&nbsp; There is a space between the /passwd and the password parameter.</li>\n\t<li>&nbsp;/s[ilent]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;The silent option will silently install the firmware, if needed.</li>\n\t<li>&nbsp;/f[orce]&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The force option will cause the OA Flash utility to either downgrade the existing firmware or reinstall the same version of firmware on the target OA.</li>\n\t<li>&nbsp;/logdir &lt;path&gt;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; This optional parameter is used to redirect the output from the OA flash utility to a different directory&nbsp;than the default location of %SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\&lt;netAddress&gt;. The redirected location is &lt;path&gt;\\hp\\log\\&lt;netAddress&gt;.</li>\n</ul>\n\n<p>To flash the firmware:</p>\n\n<ul>\n\t<li>&nbsp;Download the smart component file to a server which is on the same network as the HPE BladeSystem c-Class Onboard Administrator to be updated.</li>\n\t<li>&nbsp;Execute cpxxxxxx.exe /target &lt;netAddress&gt; /user &lt;username&gt; /passwd &lt;password&gt; [/s[ilent]] [/f[orce]] [/logdir &lt;path&gt;]</li>\n</ul>\n\n<p>The return codes are :</p>\n\n<ul>\n\t<li>&nbsp;0&nbsp; &nbsp;&nbsp; Success</li>\n\t<li>&nbsp;1&nbsp;&nbsp; &nbsp; Reserved</li>\n\t<li>&nbsp;2&nbsp;&nbsp; &nbsp;&nbsp;Upgrade is not needed because firmware version is current</li>\n\t<li>&nbsp;3&nbsp;&nbsp; &nbsp; Upgrade is not needed because newer firmware version is present</li>\n\t<li>&nbsp;4&nbsp;&nbsp; &nbsp; Target not found</li>\n\t<li>&nbsp;5&nbsp;&nbsp;&nbsp; &nbsp;User terminated session</li>\n\t<li>&nbsp;6&nbsp;&nbsp;&nbsp;&nbsp; Incorrect parameter</li>\n\t<li>&nbsp;7&nbsp;&nbsp;&nbsp;&nbsp; General failure</li>\n</ul>\n\n<p><strong>Installation Notes for using the component with HPE Smart Update Manager and the SPP</strong></p>\n\n<ol>\n\t<li>Obtain the latest version of the SPP.</li>\n\t<li>Place the SPP on a USB key using the&nbsp;<a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&amp;sp4ts.oid=8788686\">HPE USB Key Utility</a>.</li>\n\t<li>Place this component in the directory, /packages on the USB key.</li>\n\t<li>Place the USB key in a system which is on the same network as the Onboard Administrator to be updated.</li>\n\t<li>Launch hpsum from /packages.</li>\n\t<li>Follow the GUI to install the firmware on the Onboard Adminstrator.</li>\n</ol>\n\n<p><strong>Installation Notes for using the firmware extracted from the component</strong></p>\n\n<ol>\n\t<li>Extract the firmware binary out of the component.</li>\n\t<li>Place the firmware image file onto a system on the same network as the HPE BladeSystem c-Class Onboard Administrator.</li>\n\t<li>Log in to the Onboard Administrator&#39;s web-based user interface as an administrator. Firmware Update is available under the Active Onboard Administrator category. You may select the firmware image by entering a path to the file in the &quot;Local File&quot; field or by clicking on the &quot;Browse&quot; button to locate the firmware image on the local machine, a mapped drive, or a network share.</li>\n\t<li>Click &quot;Upload&quot; to begin the firmware update process.</li>\n</ol>\n\n<p>The user guide for the Onboard Administrator is located&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=c00705292\">here</a>.<br />\nThe user guide for the Onboard Administrator command line interface is located&nbsp;<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&amp;docId=emr_na-c00702815&amp;docLocale=en_US\">here</a>.</p>\n"},{"lang":"ja","x_late":"<p><strong>このコンポーネントとその中のファームウェアは、次のシナリオで使用することができます:</strong></p>\n\n<ol>\n\t<li>Onboard Administratorファームウェアの展開を記述するために使用するスタンドアロンのコンポーネント</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorにファームウェアをインストールするために、Smart Update Firmware DVD上にあるHP Smart Update Managerと共同でコンポーネントを使用することができます。</li>\n\t<li>コンポーネントから展開したファームウェアをHPE BladeSystem c-Class Onboard AdministratorのWebベースユーザーインターフェイスを使用して展開することができます。</li>\n</ol>\n\n<p><strong>コンポーネントをスタンドアロンコンポーネントで使用する場合のインストール時の注意</strong></p>\n\n<p>このSmartコンポーネントは、自己解凍型実行可能ファイルです。Smartコンポーネントは、ファイル自身を解凍し、HPE BladeSystem c-Class Onboard Administratorのファームウェアをフラッシュした後、解凍したファイルを削除します。</p>\n\n<p>このSmartコンポーネントの一般的なコマンドラインの文法は、以下のとおりです。</p>\n\n<p><br />\n   cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</p>\n\n<p><br />\ncpxxxxxx.exeは、コンポーネントのファイル名を意味します</p>\n\n<p>注記：鍵括弧でくくられたすべての引数および情報は、任意です。必要な引数がコマンドラインに含まれていない場合は、入力するようにプロンプトが表示されます。</p>\n\n<ul dir=\"ltr\">\n\t<li> /target <netAddress>           netAddressパラメーターは、ターゲットへのOAのIPアドレスまたはDNS名です。  1つのエンクロージャーに2つのOAが存在する場合は、アクティブなOAを指定する必要があります。  /targetとnetAddressパラメーターの間にはスペースが必要です。</li>\n\t<li> /user <username>               ユーザー名はOAにログインするときに使用するユーザーIDです。  /userとusernameパラメーターの間にはスペースが必要です。</li>\n\t<li> /passwd <password>            パスワードは、OAにログインするためのユーザーIDに対応するパスワードです。  /passwdとpasswordパラメーターの間にはスペースが必要です。</li>\n\t<li> /s[ilent]                                サイレントオプションは、必要な場合ファームウェアを静かにインストールします。</li>\n\t<li> /f[orce]                                forceオプションは、OAフラッシュユーティリティがターゲットOAに既存のファームウェアをダウングレード、または同じバージョンのファームウェアを再インストールするために使用します。</li>\n\t<li> /logdir <path>                     このオプションパラメーターは、OAフラッシュユーティリティからの出力をデフォルトの場所%SYSTEMDRIVE%\\CPQSYSTEM\\hp\\log\\<netAddress>ではなく、異なるディレクトリにリダイレクトするために使用します。リダイレクトされる場所は、<path>\\hp\\log\\<netAddress>です。</li>\n</ul>\n\n<p>ファームウェアをフラッシュするには、以下の手順に従ってください。</p>\n\n<ul>\n\t<li> アップデートするHPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のサーバーにSmartコンポーネントファイルをダウンロードします。</li>\n\t<li> Execute cpxxxxxx.exe /target <netAddress> /user <username> /passwd <password> [/s[ilent]] [/f[orce]] [/logdir <path>]</li>\n</ul>\n\n<p>リターンコードは、以下のとおりです。</p>\n\n<ul>\n\t<li> 0 成功</li>\n\t<li> 1 予約済み</li>\n\t<li> 2 ファームウェアのバージョンが同一のためアップグレードの必要がない</li>\n\t<li> 3  新しいバージョンのファームウェアがインストールされているためアップグレードの必要がない</li>\n\t<li> 4  ターゲットが見つからない</li>\n\t<li> 5     ユーザーによって中止されたセッション</li>\n\t<li> 6     パラメーターが不正</li>\n\t<li> 7     一般障害</li>\n</ul>\n\n<p><strong>HPE Smart Update ManagerおよびSPPとコンポーネントを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>SPPの最新バージョンを入手します。</li>\n\t<li><a href=\"https://h20565.www2.hpe.com/hpsc/swd/public/detail?swItemId=MTX_357c87ee9b054ad7a631d9eaba&sp4ts.oid=8788686\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>アップデートするOnboard Administratorと同じネットワーク上のシステムにUSBキーを接続します。</li>\n\t<li>/packagesからhpsumを起動します。</li>\n\t<li>GUIに従ってOnboard Administratorにファームウェアをインストールします。</li>\n</ol>\n\n<p><strong>コンポーネントから解凍したファームウェアを使用する場合のインストール時の注意</strong></p>\n\n<ol>\n\t<li>コンポーネントのファームウェアバイナリを展開します。</li>\n\t<li>HPE BladeSystem c-Class Onboard Administratorと同じネットワーク上のシステムにファームウェアイメージファイルをコピーします。</li>\n\t<li>Onboard AdministratorのWebベースユーザーインターフェイスに管理者でログインします。アクティブOnboard Administratorカテゴリからファームウェアのアップデートを行うことができます。［ローカルファイル］フィールドにファイルのパスを入力するか、［参照］ボタンを押してローカルマシン、割り当てられたドライブ、またはネットワーク共有から探してクリックして、ファームウェアイメージを選択します。</li>\n\t<li>［アップロード］をクリックして、ファームウェアアップデートを開始します。</li>\n</ol>\n\n<p>『Onboard Administratorユーザーガイド』は、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c00705292\">こちら</a>にあります。<br />\n『Onboard Administratorコマンドラインインターフェイスユーザーガイド』は、<a href=\"http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=3188465&docId=emr_na-c00702815&docLocale=en_US\">こちら</a>にあります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Windows 的線上 HPE BladeSystem c-Class Onboard Administrator 韌體元件"},{"lang":"en","x_late":"Online HPE BladeSystem c-Class Onboard Administrator Firmware Component for Windows"},{"lang":"ko","x_late":"Windows용 온라인 HPE BladeSystem c-Class Onboard Administrator 펌웨어 구성 요소"},{"lang":"cn","x_late":"用于 Windows 的联机 HPE BladeSystem c-Class Onboard Administrator 固件组件"},{"lang":"ja","x_late":"オンラインHPE BladeSystem c-Class Onboard Administratorファームウェアコンポーネント for Windows"}],"prerequisites":{"required_diskspace":{"size_kb":"10000"},"supported_devices":[{"id":"403318-B21 ","target_guid":"","type":"other"},{"id":"437502-B21","target_guid":"","type":"other"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-12-03T12:17:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Onboard Administrator 4.96&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>AlertMail feature now supports two priorities that a user can select for the AlertMail messages.</li>\n\t<li>Enclosure Firmware Management (EFM) feature is optimized to speed up the EFM update operation.</li>\n\t<li>The SSL certificate of Onboard Administrator now supports Fully Qualified Domain Name (FQDN) in <strong>Common Name</strong> (CN) field and IP address in <strong>SAN </strong>field.</li>\n\t<li>Common Access Card (CAC) Authentication feature is enhanced to support a configurable timeout for the SSL session.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>Onboard Administrator supports two new TLS_DHE_RSA ciphers.</li>\n\t<li>FIPS TOP-SECRET mode ciphers are now supported in FIPS <strong>ON </strong>and <strong>OFF </strong>modes.</li>\n\t<li>CLI commands SHOW SSH CIPHER, ENABLE SSH CIPHER and DISABLE SSH CIPHER are added to Show, Enable and Disable SSH ciphers in FIPS ON and OFF modes.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>General</strong></p>\n\n<ul>\n\t<li>Addressed an issue where SNMP queries to Onboard Administrator OIDs were not successfully completed when VLAN is configured for Blades and Interconnects.</li>\n\t<li>.Addressed an issue in the Device and Rack Summary GUI page to eliminate the duplicate display of FLB and Mezz adapters information.</li>\n\t<li>Addressed an issue where Interconnects were not receiving IP address from EBIPA (or) external DHCP server.</li>\n\t<li>Addressed an issue where Blade Location information was not displayed correctly in SHOW SERVER STATUS ALL CLI command.</li>\n\t<li>Addressed an issue where DNS record update was getting delayed in DNS server when a user configured a domain name in Onboard Administrator</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n"},{"curr_enhancements_x_late":"<p>Onboard Administrator 4.97&nbsp;provides support for the following enhancements:</p>\n\n<p><strong>Hardware additions</strong></p>\n\n<ul>\n\t<li>None</li>\n</ul>\n\n<p>Features<strong>: additions and changes</strong></p>\n\n<p><strong>General</strong></p>\n\n<ul>\n\t<li>A new feature is added to SNMP to support enable/disable options for v1/v2c protocols.</li>\n\t<li>New SNMP traps were added for emergency brake (e-brake) activated and deactivated events.</li>\n\t<li>Added support for firmware update of new NIDEC fans.</li>\n\t<li>Enhanced PowerPIC firmware update to support firmware version 1.8.</li>\n\t<li>In the Onboard Administrator GUI added support for iLO HTML5 IRC console.</li>\n</ul>\n\n<p><strong>&nbsp;Security</strong></p>\n\n<ul>\n\t<li>A new feature is added in SSH to support enable/disable of Key Exchange (KEX) Algorithms.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>General</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li>Addressed an issue where running concurrent UPDATE ILO cli command from different SSH sessions cause few of the commands to end in operation failure.</li>\n\t<li>Fixed an issue in SET SERVER DVD CONNECT cli command usage in IPv6 environment.</li>\n\t<li>Addressed an issue where blade&rsquo;s ProductID update in System Rom RBSU is not reflected in the Onboard Administrator.</li>\n\t<li>Harnessed certificate read operation from flash to minimize certificate read failures.</li>\n\t<li>Fixed an issue in SNMP v3 protocol where EngineTime was not reset on increment of EngineBoot count.</li>\n\t<li>Addressed an issue related to blade discovery failure</li>\n\t<li>Fixed an issue in Smart Component where it fails to establish communication with Onboard Administrator using DHE ciphers.</li>\n\t<li>Addressed an issue related to ECDSA ciphers enable/disable feature.</li>\n\t<li>Added SSH cipher list to the configuration script</li>\n\t<li>Fixed an issue in Onboard Administrator GUI where IPv4 DynamicDNS could not be enabled when enclosure is configured for static IP configuration.</li>\n\t<li>Fixed help message display issues in CLI commands SET SSL_SESSION TIMEOUT and SET SECURESH.</li>\n\t<li>Addressed an issue in SNMP where EngineBoot count was incremented by two for add/delete of trap receiver.</li>\n\t<li>Fixed Online Help (OLH) pages display issue that occur when language pack is uploaded into Onboard Administrator.</li>\n</ul>\n\n<p><strong>Security</strong></p>\n\n<p>&nbsp;</p>\n\n<p>The following security vulnerabilities are fixed:</p>\n\n<ul>\n\t<li>Onboard Administrator&rsquo;s web server response is enhanced to include X-Content-Type-Options security header.</li>\n\t<li>CVE-2011-3026 - libpng: Heap buffer overflow</li>\n\t<li>CVE-2018-1000517 - BusyBox wget version&nbsp; contains a Buffer Overflow vulnerability</li>\n\t<li>CVE-2020-1971 - EDIPARTYNAME NULL pointer de-reference</li>\n\t<li>CVE-2020-15861 - Net-SNMP allows Escalation of Privileges</li>\n\t<li>CVE-2020-15862 - Net-SNMP provides the ability to run arbitrary commands as root.</li>\n\t<li>CVE-2019-20892 &ndash; SNMPv3 get bulk request issue<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Issues and workarounds</strong></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Browsers</strong></p>\n\n<ul>\n\t<li>OA GUI is not accessible in Chrome versions 43.0.2357.10 to 44.0.2383.The issue was caused by a &ldquo;regression&rdquo; in Chrome (or WebKit). Customers should use an alternative browser like Firefox or Internet Explorer or try a different version of Chrome.</li>\n\t<li>SSO-to-iLO connection from the OA using an iLO host name fails with Microsoft Internet Explorer11 on Windows 8. On a Windows 8 system with Internet Explorer 10 or Internet Explorer 11, if the OA web GUI session is loaded using a host name instead of an IP address, an attempt to open an iLO window using SSO from the OA web GUI might result in the iLO page loading in the OA web GUI window instead of the intended new window. This issue was determined to be a bug in Internet Explorer and is expected to be fixed in a future release or update for Internet Explorer. To work around this issue, either use an IP address to load the OA Web GUI, or turn off Protected Mode for the appropriate zone in Internet Explorer&rsquo;s settings. This issue occurs only on Internet Explorer browsers.</li>\n</ul>\n\n<p><strong>FIPS</strong></p>\n\n<p style=\"margin-left:40px\">Certificates smaller than 2048 bits in size are not compliant with FIPS requirements as enforced by the OA firmware starting with OA 4.20. When the OA running OA firmware version 4.40 or greater is operating in FIPS Mode ON/DEBUG and is configured with a 1024-bit LDAP certificate that was installed when running a previous version of OA firmware, FIPS Mode ON/DEBUG is considered to be operating in a degraded state due to the presence of the non-compliant certificate. While operating in this FIPS-Degraded Mode operational state, attempts to set FIPS Mode OFF from the OA GUI Network Access&gt;FIPS tab will fail and show the error message The selected FIPS mode is already enabled. When the non-compliant certificate is removed, the FIPS-Degraded operational status is cleared, FIPS Mode can then be successfully set to OFF from the GUI interface. Note that the OA CLI command SET FIPS MODE OFF can be successfully used to set FIPS Mode OFF even with non-compliant 1024-bit LDAP certificates installed in the OA.</p>\n\n<p><strong>IRC</strong></p>\n\n<p style=\"margin-left:40px\">Unable to open .net IRC console for Gen10 Blades, Gen9 Blades also have the same issue. The Java applet and Webstart however, loads but the virtual media mounting fails. The work around is to launch the IRC through IRC Application (HPE&nbsp;Lights-Out Stand Alone Remote Console) which is installed on terminal client.</p>\n\n<p><strong>EFM</strong></p>\n\n<p style=\"margin-left:40px\">To use EFM on Gen 10 Blades, please select options/filters &ldquo;<em>Make Bootable ISO file&rdquo; and&nbsp;</em>&ldquo;<em>Enclosure Firmware Management&rdquo;</em>&nbsp;while creating custom SPP ISO on HPE SUM 8.0.0. Please refer to HPE SUM 8.0.0 User guide for further details.</p>\n\n<p><strong>CAC</strong></p>\n\n<ul>\n\t<li>In the CAC mode SSH, Telnet and XML Reply protocols will be disabled.</li>\n\t<li>Linked enclosure login will not work if the linked enclosure in CAC mode.</li>\n\t<li>If accurate Service account details are not provided, LDAP user login with certificate will fail.</li>\n\t<li>It is highly recommended to establish a recovery plan before getting started with CAC.&nbsp; If something goes wrong with the OA configuration, the OA may be recovered through the serial port or Insight Display panel and USB KEY. Both methods require physical access to the OA.&nbsp; However, if an LCD PIN has been configured (and forgotten) and local accounts have been disabled or CAC has been incorrectly configured then, the only way to recover is through a serial port. The two most common situations where OA recovery is needed are when LDAP has been configured incorrectly with local accounts disabled or when CAC has been configured without certificate access.</li>\n</ul>\n\n<p><strong>Configurable SSH Port Number&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong></p>\n\n<p style=\"margin-left:0in; margin-right:0in\">If a Standby OA is running firmware version less than 4.85 and it is updated to firmware version greater than or equal to 4.85 using synchronize firmware feature from Active OA, after the firmware update and reboot of the Standby OA, SSH port will not open in the configured port number. The work around is to reboot the Standby OA and SSH port will open in the configured port in next boot. This issue will not occur in the case where SSH port is configured to default port 22 in the Active OA.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>Smart component</strong></p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">When OA is in FIPS ON or FIPS TOP-SECRET mode and any of the ciphers that use&nbsp;&nbsp;&nbsp;Diffie-Hellman (DH) keys are enabled, firmware upgrade or downgrade using OA Smart&nbsp;&nbsp;Component 4.96 or earlier versions may fail with following error:</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator. Verify the target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS ON</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_3DES_EDE_CBC_SHA<br />\nTLS_DHE_RSA_WITH_AES_128_GCM_SHA25<br />\nTLS_DHE_RSA_WITH_AES_256_GCM_SHA384<br />\nTLS_DHE_RSA_WITH_AES_128_CBC_SHA256<br />\nTLS_DHE_RSA_WITH_AES_256_CBC_SHA256</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">FIPS TOP-SECRET</p>\n\n<p style=\"margin-left:80px\">TLS_DHE_RSA_WITH_AES_256_GCM_SHA384</p>\n\n<p>&nbsp;&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Same error may occur when OA upgrade or downgrade is performed through Smart&nbsp;&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Update Manager (SUM) resulting in the following error message in the SUM.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Component&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Package&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Deployment Status&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Log</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; ----------------------------------------------------------------------------------------------------------------------------------------------------------</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; cpC39063&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online HPE BladeSystem c-Class Onboard Administrator for Windows&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Update returned an error&nbsp;&nbsp;&nbsp;&nbsp; View Log</p>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp;&nbsp;When this failure occurs, the following message can be seen in the OA Smart Component&nbsp;&nbsp;log file.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Error: 1013: Client cannot connect with the Onboard Administrator.</p>\n\n<p style=\"margin-left:40px\">&nbsp;&nbsp; Verify&nbsp;The target address is correct and can be accessed from your system.</p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around for this problem is to disable all the ciphers that use DH&nbsp;&nbsp;key and rerun the firmware upgrade or downgrade.</p>\n\n<p style=\"margin-left:40px\">Disabling ciphers can be&nbsp;done using the CLI command DISABLE SSL CIPHER or through the GUI.&nbsp; The disabled ciphers can be re-enabled once the firmware upgrade or&nbsp;downgrade is completed.</p>\n\n<p style=\"margin-left:0in; margin-right:0in\">&nbsp;</p>\n\n<p><strong>ILO5 Firmware Update</strong></p>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The UPDATE ILO command is failing to update the iLO5 firmware versions 2.10 and later on&nbsp;OA version 4.90 and less than 4.90. This issue is caused by the introduction of new&nbsp;&nbsp; signature in the iLO5 firmware version 2.10.</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; The work-around is to update the OA firmware&nbsp;&nbsp;to 4.95 and then try the UPDATE ILO command. This issue will not occur with OA versions&nbsp;&nbsp;4.95 and later.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"BL860ci2","value":"HP Integrity BL860c i2 Server Blade"},{"key":"A26","value":"HP ProLiant BL465c Gen8 Server"},{"key":"I32","value":"HP ProLiant BL660c Gen8 Server"},{"key":"BL870ci2","value":"HP Integrity BL870c i2 Server Blade"},{"key":"BL890ci2","value":"HP Integrity BL890c i2 Server Blade"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I30","value":"HP ProLiant BL420c Gen8 Server"},{"key":"I31","value":"HP ProLiant BL460c Gen8 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"","value":"HPE Integrity BL870c i6 Server Blade"},{"key":"I31","value":"HP ProLiant WS460c Gen8 Graphics Server Blade"},{"key":"BL860ci4","value":"HP Integrity BL860c i4 Server Blade"},{"key":"BL870ci4","value":"HP Integrity BL870c i4 Server Blade"},{"key":"BL890ci4","value":"HP Integrity BL890c i4 Server Blade"}],"sw_keys":[{"name":"OA","sw_key_expectedpath":"firmware:oa"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.56(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added HPE Smart Array P824i-p controller&nbsp;support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"10257599","datemodified":"2018-12-12T14:13:54","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/CP037766.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/Talladega-Release-1.56-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/libsetup2.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/setup2","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/storcli-1.25.12-1.noarch.rpm","./usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-1.56-3.1/supplement","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037766.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037766.scexe"],"md5sum":"f616851c186ef1fd361cba750a5310bc","name":"firmware-smartarray-815b1ae26d-1.56-3.1.x86_64.rpm","release":"2018-12-12T20:09:13","revision":"0","sha1sum":"f480236b56ed307607026b69f1ad7a294cc3c8af","size":"9MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56"}],"id":{"product":"8ab91a2b5ff149e8a59b3d86d5fbcc3d","version":"a77e6866a83f46a1a35d16f76a8417ba"},"installation":{"command":"CP037766.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037766.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-815b1ae26d-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037766.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-815b1ae26d-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-815b1ae26d-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Supplemental Update / Online ROM Flash Component for Linux (x64) - HPE Apollo 45xx Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"サプリメンタルアップデート/オンラインROMフラッシュコンポーネント for Linux (x64) - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-03T16:52:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array P824i-p controller&nbsp;support&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"9300211","languages":[{"lang":"fr","x_late":"Utilitaire - Outils"},{"lang":"en","x_late":"Utility - Tools"},{"lang":"cn","x_late":"实用程序 - 工具"},{"lang":"tw","x_late":"公用程式 ─ 工具"},{"lang":"de","x_late":"Hilfsprogramm - Tools"},{"lang":"ko","x_late":"유틸리티 – 도구"},{"lang":"it","x_late":"Utility - Strumenti"},{"lang":"ja","x_late":"ユーティリティ - ツール"},{"lang":"es","x_late":"Utilidad - Herramientas"}]}],"description":[{"lang":"en","x_late":"This package contains the HPE NVMe Name Server host agent kit supporting RoCEv2 capable HPE 25Gb Ethernet adapters  & HPE 100Gb Ethernet adapters for Linux operating systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム用のRoCEv2対応HPE 25GbイーサーネットアダプターおよびHPE 100GbイーサーネットアダプターをサポートするHPE NVMeネームサーバーホストエージェントキットが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"84308","datemodified":"2022-01-24T08:59:08","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"9468d69a0dbbec86dd4c482549ed70d5","name":"HPE-NFC-host-agent-SLES-1.1-1.sles15sp2.x86_64.rpm","release":"2022-01-24T08:52:55","revision":"0","sha1sum":"02f517b35c5660b7f5dd6f98efbc8b76f3e5b025","size":"82KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50573ade"],"type_of_change":"1","version":"1.1-1"},{"bytes":"84311","datemodified":"2022-01-24T08:56:31","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"0377f406e8543c27250f5779ad11a002","name":"HPE-NFC-host-agent-SLES-1.1-1.sles15sp3.x86_64.rpm","release":"2022-01-24T08:52:55","revision":"0","sha1sum":"3ee1ec2de94e3eeff1068d4101941118fb79e9d0","size":"82KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50573ade"],"type_of_change":"1","version":"1.1-1"},{"bytes":"84312","datemodified":"2022-01-24T09:00:16","file_list":["./etc/nfc_nvme/hpe_nfc_nnscid.conf","./usr/lib/systemd/system/nns_service.service","./usr/sbin/nfc_config","./usr/sbin/nfc_param_set","./usr/sbin/nnsciadm","./usr/sbin/nnscid","./usr/share/smartupdate/HPE-NFC-host-agent-SLES/component.xml"],"md5sum":"4706667ee1e7c54b082ebf8da9562a40","name":"HPE-NFC-host-agent-SLES-1.1-1.sles12sp5.x86_64.rpm","release":"2022-01-24T08:52:55","revision":"0","sha1sum":"fae6e9cec24420d756ab4f54c5682f927f5b8cee","size":"82KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec50573ade"],"type_of_change":"1","version":"1.1-1"}],"id":{"product":"8bba948f5c6540eba0ebe40d14f02daf","version":"77f3ea0dd2f146d0a61c0c6dfe65df3d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE NFS host agent for SuSE Linux Enterprise Server 12 Service Pack5/15 Service Pack2"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"037D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101d1590037d","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Version</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Version</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"},{"name":"HPE-NFC-host-agent-SLES","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR416i-a","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR416i-a_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR416i-a Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7491287","datemodified":"2021-09-08T14:48:55","file_list":["HPE_MR416i-a_Gen10P_52.16.3-3913.ilo","HPE_MR416i-a_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"38f07a6af47266ee6dc2cc85be6ed69c","name":"HPE_MR416i-a_Gen10P_52.16.3-3913.fwpkg","release":"2021-09-08T14:45:15","revision":"0","sha1sum":"4c441280b1c4213fdb3670a1a94abd079a395b03","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032a"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"c9a4232d8cb349049f544bcc6d02e97f","version":"a468c99b4c154eb1846dc4eca575ef0e"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR416i-a Gen10 Plusトライモードコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"32000"},"supported_devices":[{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T14:09:40","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"032A1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE Blade Intel ixgbe Ethernet NICs running under SUSE Linux Enterprise Server 12."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12で動作するHPE Blade Intel ixgbe Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4216191","datemodified":"2021-03-08T18:14:03","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/hp-ixgbe","./lib/modules/4.12.14-120-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"203b91ac5167e02c38e1de393b0cc8cc","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"8d5cc710beefa743ae2adda67fa78b8f8a0360c8","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"},{"bytes":"4099344","datemodified":"2021-03-08T18:15:23","file_list":["./lib/modules/4.12.14-94.41-default","./lib/modules/4.12.14-94.41-default/updates","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe","./lib/modules/4.12.14-94.41-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe_bl-kmp-default/component.xml"],"md5sum":"a339e4390c75808ef95dae101c437133","name":"hp-ixgbe_bl-kmp-default-5.9.4_k4.12.14_94.41-1.sles12sp4.x86_64.rpm","release":"2021-03-08T18:04:08","revision":"0","sha1sum":"c8ddbf34e027cc801dcab7917bd100c63f5268fb","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecf57995ac"],"type_of_change":"0","version":"5.9.4-1"}],"id":{"product":"5eee6ab16a2542c6ab8115b98b119c8f","version":"de1c9c07fe0f4f4d834b26da4175dabe"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Intel ixgbe Drivers for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Blade Intel ixgbeドライバーfor SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10F8","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c18d0","type":"pci","ven":"8086"},{"dev":"10F8","subdev":"17D2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10f8103c17d2","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"18D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c18d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D2","subven":"103c","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d2","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-02-26T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 SP5.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"hp-ixgbe_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33602297","datemodified":"2022-03-08T14:20:53","file_list":["payload.json","U41_2.62_03_08_2022.signed.flash","U41_2.62_03_08_2022.xml"],"md5sum":"370e62021f453f88dabbbcd622ecbb76","name":"U41_2.62_03_08_2022.fwpkg","release":"2022-03-08T14:17:20","revision":"0","sha1sum":"52b1a2af909f5b8d4d317f5adc26cebe02ab3f18","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"2b44e5307a9948769c51d6ac1f276915","version":"163e6086894f412488c43ccd86bccfac"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-07T08:12:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.05.03"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.05.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters. "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"3510568","datemodified":"2021-09-02T07:36:01","file_list":["QLAFWUpdate.exe","adapters.properties","bk017507.bin","cp046938.xml","cpqsetup.exe","installer.dll","mh020503.bin","payload.json","qlafwupdate.properties","qlafwupdate.txt","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"md5sum":"e13911a38d0067970cf9a0e54a466f54","name":"cp046938.exe","release":"2021-09-02T07:20:04","revision":"0","sha1sum":"5fb1d9cf000a991314b43ade40d116f46f7f41b2","size":"3MB","target_guids":["a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"635ad6621b8d4c52b8b9de3325345e84","version":"810cbe89053449ad9ece0292b206c99b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component number.<br />\n<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br />\n<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2016/2019/2022 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-23T06:15:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p dir=\"LTR\">&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a&nbsp;behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"qlogic","sw_key_expectedpath":"firmware:qlogic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG2"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG2"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG2"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"26056571","datemodified":"2021-12-23T05:04:48","file_list":["/CP050579_BUILD_1.data","/CP050579.vmexe","/CP050579.vmexe64","/CP050579.vmfile","/CP050579_VMw.zip","/CP050579.xml","/payload.json","/CP050579_VMw.zip/index.xml","/CP050579_VMw.zip/vendor-index.xml","/CP050579_VMw.zip/metadata.zip","/CP050579_VMw.zip/vib20/CP050579/HPE_bootbank_CP050579_HPG2.1-7.0.0.15843807.vib","/CP050579_VMw.zip/metadata.zip/vendor-index.xml","/CP050579_VMw.zip/metadata.zip/vmware.xml","/CP050579_VMw.zip/metadata.zip/vibs/CP050579--7584378716664132224.xml","/CP050579_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050579_HPG2.1-7.0.0.15843807.xml"],"md5sum":"6a5e7abb877821f95c6a0857e3a3a0d2","name":"CP050579.zip","release":"2021-12-23T05:02:34","revision":"0","sha1sum":"95764066079a0d82d7a5f7894cacadfe7aa6d33e","size":"24MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG2","vib_list":[{"name":"CP050579","version":"HPG2.1-7.0.0.15843807"}]}],"id":{"product":"8e9f61780275418686c8b0a671e012c9","version":"eada2750b7f04912ae3aa09734ef26d1"},"installation":{"command":"CP043256.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant</a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-20T06:55:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Linux x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06251-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"8309286","datemodified":"2022-02-09T11:53:37","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/CP050423.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw/fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw/fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw/fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050423.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050423.scexe"],"md5sum":"919ab25fb6e0319974e385eecad7dfc8","name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.8-1.1.x86_64.rpm","release":"2022-02-09T11:51:23","revision":"0","sha1sum":"79b7ae6842857161d1048b1cccc49b59119cbd22","size":"7MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.8"}],"id":{"product":"dcf87aae93de4d649fef4547bffe751a","version":"6736fd5a6c234725be68b4eb57d902ad"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T07:06:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21</p>\n\n<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot.&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n<strong>Additional Fixes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>\n\t<li>Improved PortXmitWait IB counter accuracy.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 20.32.1010:</strong></p>\n\n<ul>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06251-B21</li>\n</ul>\n\n<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. If case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit per-host per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n\t<li>Limited the external loopback speed according to the used module&#39;s capabilities.</li>\n\t<li>Modified the Effective BER calculation method. Due to this, the value of the Effective BER will be slightly higher, however the link quality remains the same as prior to this change.</li>\n\t<li>This firmware version includes the following PCIe changes:\n\t<ul>\n\t\t<li>Fixed the ACS Port Number field in DSPs and ACS Egress Control Vector field in DSPs.</li>\n\t\t<li>Added support for VSC on USP of PCIe Switch.</li>\n\t\t<li>Fixed the mapping of Legacy Interrupts in the PCIe Switch.</li>\n\t\t<li>Fixed MRRS &amp; MPS configurations in DSPs.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>System could not create more than 128K QPs.</li>\n\t<li>Incorrect indication of the PCIe link down in the AER registers on PCIe switch upstream port.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The flash frequency on boot was lower than expected (under 50Mhz). The issue was fixed by enabling the firmware to increase it on boot2 to normal frequency.</li>\n\t<li>A race condition between DC QP flush and DC packets that led to stuck slices in the hardware. To avoid such situation, firmware keeps the TCU drop set until QP flush is done.</li>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Smart Array P-series and E-series Gen10 controllers. This RPM provides a customer friendly approach to install a pre-built binary driver.\nOn some kernel erratas the version of the driver present in the kernel may be equal to the version being installed by the rpm.  However, the driver in the kernel may not include all of the fixes and enhancements implemented in the driver contained within the rpm.  Therefore the rpm should be installed in order to obtain the fixes and enhancements that are not present in the kernel driver."},{"lang":"ja","x_late":"このRPMは、HPE SmartアレイPシリーズおよびEシリーズGen10コントローラーを有効にするためビルド済みのバイナリドライバーモジュールを提供します。 このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。\nerrataカーネルによっては、カーネル内に存在するドライバーのバージョンとrpmによってインストールされたバージョンが等しい場合があります。  だたし、カーネル内のドライバーは、rpmに含まれるドライバーに対して行われた、すべての修正と拡張が含まれていないことがあります。  そのため、rpmはカーネルドライバーに存在しない、修正と拡張を入手するため、インストールする必要があります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"627909","datemodified":"2022-01-27T10:15:32","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/smartpqi","./lib/modules/3.10.0-1160.el7.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"c20cd5cb48e3bae7adf5c7079e649797","name":"kmod-smartpqi-2.1.16-030.rhel7u9.x86_64.rpm","release":"2022-01-27T10:07:15","revision":"0","sha1sum":"7fcaf9e689092471afe745b19755f1dd2b581212","size":"613KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.16-030"},{"bytes":"627390","datemodified":"2022-01-27T10:19:49","file_list":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/smartpqi","./lib/modules/3.10.0-1127.el7.x86_64/extra/smartpqi/smartpqi.ko","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"md5sum":"dfc6826d452b6478bb274c74f7098fa5","name":"kmod-smartpqi-2.1.16-030.rhel7u8.x86_64.rpm","release":"2022-01-27T10:07:15","revision":"0","sha1sum":"94aba81f0be9fe93a455c27ada436de193233393","size":"612KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"type_of_change":"1","version":"2.1.16-030"}],"id":{"product":"a25209e630db46018590185244995b68","version":"9317f65e7a194280a9359a990b456e91"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on<br />\nyour hard drive and change to that directory.</p>\n\n<p><strong>To install or upgrade&nbsp;the driver type:</strong></p>\n\n<p>&nbsp;</p>\n\n<ul>\n\t<li># rpm -Uvh kmod-smartpqi-&lt;version&gt;.rhel7&lt;OSupdate&gt;.x86_64.rpm&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p style=\"margin-right:0px\">Setup is now complete. Please REBOOT your computer NOW!!</p>\n\n<p><strong>NOTE</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:</p>\n\n<ul>\n\t<li># rpm -e kmod-smartpqi-&lt;version&gt;.rhel7&lt;OSupdate&gt;.x86_64.rpm</li>\n</ul>\n\n<p><strong><u>Enterprise Support</u></strong><br />\nFor support on Smart Array controllers, visit <a href=\"http://www.hpe.com/support\">http://www.hpe.com/support</a></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE ProLiant Gen10 and Gen10Plus Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 7 (64-bit)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"028F","subdev":"0701","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0701","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0700","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0700","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0655","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0655","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1101","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1101","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0294","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f15900294","type":"pci","ven":"9005"},{"dev":"028F","subdev":"02DC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-9005-028f159002dc","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-30T15:52:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where duplicate device nodes for Ultrium tape drive and medium changer are being created.</li>\n\t<li>Fixed an issue where the OS boot could fail during logical volume rebuild.</li>\n\t<li>Fixed an issue to avoid failing IOs for devices which are offline.</li>\n\t<li>Fixed an issue where request_irq failed during system hibernation.</li>\n\t<li>Fixed take a long time to come up if the system is rebooted while a hard disk(s) is being sanitized on RHEL 7.9.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"},{"name":"kmod-smartpqi","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4181456","datemodified":"2021-07-23T11:56:45","file_list":["cp048671.xml","cpqsetup.exe","HLIBRHHaseFG5.rel","payload.json","setup.dll"],"md5sum":"d85a8df3d24d1eaac029c09986ff49e1","name":"cp048671.exe","release":"2021-07-23T11:47:07","revision":"0","sha1sum":"7dfb4f2a6a6bbd3ab3450dd978f30b63c3c0173b","size":"3MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5"}],"id":{"product":"70cd98996b234f1990b49a33858ae471","version":"c077cfcf59984d1f9f3243bfc722b64e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64) - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:25:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.Â </li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 7.0."},{"lang":"ja","x_late":"この製品は、VMware vSphere 7.0上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.4.17.0</li>\n\t<li>qcnic, version 2.0.59.0</li>\n\t<li>qfle3i, version 2.1.8.0</li>\n\t<li>qfle3f, version 2.1.25.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>この製品には、以下のドライバーが含まれています。</p>\n\n<ul>\n\t<li>qfle3、バージョン1.4.17.0</li>\n\t<li>qcnic、バージョン2.0.59.0</li>\n\t<li>qfle3i、バージョン2.1.8.0</li>\n\t<li>qfle3f、バージョン2.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1513240","datemodified":"2021-11-24T06:36:05","file_list":["/cp049987.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.60.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.22.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.8.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.25.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vibs/qfle3-8898444055263122491.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vibs/qcnic--2873218953053595309.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vibs/qfle3i--558247773911429780.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/vibs/qfle3f--371781071515599867.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807_18598311.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.157.0-1OEM.700.1.0.15843807.xml"],"md5sum":"26e4a4cbe88a459227830dadd4bd6ade","name":"cp049987.zip","release":"2021-11-24T06:31:50","revision":"0","sha1sum":"e225b26e6ad5a6abb24531b537c780fcf766cc74","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"qcnic","version":"2.0.60.0-1OEM.700.1.0.15843807"},{"name":"qfle3","version":"1.4.22.0-1OEM.700.1.0.15843807"},{"name":"qfle3i","version":"2.1.8.0-1OEM.700.1.0.15843807"},{"name":"qfle3f","version":"2.1.25.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"38b83226aeb64480960e8558ac22cab4","version":"74bcf553598144788b03472bfe0de77b"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 7.0"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバーfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-17T06:41:10","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This products enhances the mechanism that collation of data log.</li>\n\t<li>This product now supports ESXi 7.0 U3.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qfle3:1.4.22.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.157.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"qfle3i:2.1.8.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qcnic:2.0.60.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:2.1.25.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2019."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2019用のHPE Blade Emulex 10/20GbサーバーアダプターのiSCSIドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"905664","datemodified":"2021-07-21T18:22:06","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp049074.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"57f5f9452928c2f50de962a0d4a4e975","name":"cp049074.exe","release":"2021-07-21T18:08:05","revision":"0","sha1sum":"67c939943fa0c98e8d8b64298a74eb22d602b06f","size":"884KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"36e4d61e9116490288f4da49e28def20","version":"efd3c86dc97d4670a4c8153e580d1a67"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2019"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20 GbE iSCSIドライバーfor Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the&nbsp;HPE ProLiant BL660c Gen9 Server.&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD4"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD4"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD4"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD4"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM1643ASAD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16577408","datemodified":"2021-08-27T13:47:25","file_list":["/CP048455_BUILD_2.data","/CP048455.vmexe","/CP048455.vmexe64","/CP048455.vmfile","/CP048455_VMw.zip","/CP048455.xml","/payload.json","/CP048455_VMw.zip/index.xml","/CP048455_VMw.zip/vendor-index.xml","/CP048455_VMw.zip/metadata.zip","/CP048455_VMw.zip/vib20/CP048455/HPE_bootbank_CP048455_HPD4.2-7.0.0.15843807.vib","/CP048455_VMw.zip/metadata.zip/vendor-index.xml","/CP048455_VMw.zip/metadata.zip/vmware.xml","/CP048455_VMw.zip/metadata.zip/vibs/CP048455-1749296248874906850.xml","/CP048455_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048455_HPD4.2-7.0.0.15843807.xml"],"md5sum":"6492b6e7df5cc02d7db812e63f96e2be","name":"CP048455.zip","release":"2021-08-27T13:42:55","revision":"0","sha1sum":"74dd4380857cbf20fcb9317f9cc90d03f18b0e57","size":"15MB","target_guids":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048455","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"0b3bbfed90454334ba3331c2f9efa2ea","version":"d9623e2c915e494594436e6c885a4931"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: blue; text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\" style=\"color: blue; text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\" style=\"color: blue; text-decoration: none;\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VO000960JWZJF、VO001920JWZJH、VO003840JWZJK、 VO007680JWZJLおよびVO015360JWZJNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO015360JWZJN","target_guid":"562340a5-304f-3531-3336-304a575a4a4e","type":"sas"},{"id":"VO007680JWZJL","target_guid":"562340a5-304f-3730-3638-304a575a4a4c","type":"sas"},{"id":"VO003840JWZJK","target_guid":"562340a5-304f-3330-3834-304a575a4a4b","type":"sas"},{"id":"VO001920JWZJH","target_guid":"562340a5-304f-3130-3932-304a575a4a48","type":"sas"},{"id":"VO000960JWZJF","target_guid":"562340a5-304f-3030-3936-304a575a4a46","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T08:02:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Modify Drive Vendor Identification String (VID) in Inquiry page from &ldquo;HP&rdquo; to &ldquo;HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO015360JWZJN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680JWZJL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920JWZJH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960JWZJF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840JWZJK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5390676","datemodified":"2021-08-25T07:08:06","file_list":["/CP046785_BUILD_15.data","/CP046785.vmexe","/CP046785.vmexe64","/CP046785.vmfile","/CP046785_VMw.zip","/CP046785.xml","/payload.json","/CP046785_VMw.zip/index.xml","/CP046785_VMw.zip/vendor-index.xml","/CP046785_VMw.zip/metadata.zip","/CP046785_VMw.zip/vib20/CP046785/HPE_bootbank_CP046785_2021.10.01.15-6.5.0.4240417.vib","/CP046785_VMw.zip/metadata.zip/vendor-index.xml","/CP046785_VMw.zip/metadata.zip/vmware.xml","/CP046785_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046785_2021.10.01.15-6.5.0.4240417.xml","/CP046785_VMw.zip/metadata.zip/vibs/CP046785-8302153304802469471.xml"],"md5sum":"f479078bb4b9c3510b12c668cd990fd9","name":"CP046785.zip","release":"2021-08-25T07:03:05","revision":"0","sha1sum":"7b8c0b7dd46b4a64063937f087d384fd0cef2513","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046785","version":"2021.10.01.15-6.5.0.4240417"}]}],"id":{"product":"a5a34b70caa4482380a015cc4a6e9c97","version":"047df9e0e0624b5b890599d27b0ace6b"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Distributed Management Task Force (DMTF) &ndash; Platform Level Data Model (PLDM) Firmware Update to the SN1200E, SN1600E, and SN1610E</li>\n\t<li>The adapter will now reset to defaults when the user activates Hewlett Packard Enterprise (HPE) Secure Erase from Hewlett Packard Enterprise (HPE) intelligent provisioning</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior&nbsp;where the SN1600E would wrongly display an unwanted message when loading Unified Extensible Firmware Interface (UEFI) driver defaults</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMは、HPE Storageファイバーチャネルアダプターおよびメザニンホストバスアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"531993","datemodified":"2021-11-17T05:14:50","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1127.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"2b9c421bee4eb20c9ad3e992483bb2e3","name":"kmod-elx-lpfc-12.8.528.7-1.rhel7u8.x86_64.rpm","release":"2021-11-17T05:09:09","revision":"0","sha1sum":"76ad10a34dfb3abfa909f626c56750852faefd58","size":"519KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"e72cd1a2f7704ea68d5be6e8ad810600","version":"f3da254280384ad684853d449bcc334f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1.  システム管理者 (root) としてログインします。</p>\n\n<p>2.  RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3.  ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.  インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 8 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 Update 8 Serverファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプターおよびメザニンホストバスアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on Red Hat Enterprise Linux 8 Server for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージには、Red Hat Enterprise Linux 8 Server上でEmulexホストバスアダプターおよびメザニンホストバスアダプターに対してHPE Storageファイバーチャネルアレイ接続を有効にするためのユーティリティとライブラリが含まれています。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"991165","datemodified":"2021-11-15T07:27:34","file_list":["./opt/emulex/rhel8/x86_64/lib64/libdfc.so","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12","./opt/emulex/rhel8/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/rhel8/x86_64/lib64/libemsdm.so","./opt/emulex/rhel8/x86_64/lib64/libemulexhbaapi.so","./usr/lib/.build-id","./usr/lib/.build-id/be","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955","./usr/lib/.build-id/be/cb7ea05c40554a20668a35f4fb5439d6ccd955.1","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/793599f422ad7b0bc69185eaffaf80d457dffb","./usr/lib/.build-id/c6/793599f422ad7b0bc69185eaffaf80d457dffb.1","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7","./usr/lib/.build-id/f5/0d4d3acef5d038c3c45a59e9e47190964faff7.1","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"14f5c7be955adb939f555843de5d2d7d","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.rhel8.x86_64.rpm","release":"2021-11-15T07:21:56","revision":"0","sha1sum":"a013470e32d411f9076fb794a3cbcda4ebd5ffc5","size":"967KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.526.0"}],"id":{"product":"55aaafbf4e5149bd9a06cddaff69d915","version":"0435a90c0166443c8dd37c683ed0c1ae"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"},{"lang":"ja","x_late":"<p>イネーブルメントキットのインストール前にターゲット環境にlibHBAAPIパッケージをインストールしておく必要があります。（存在していない場合、libHBAAPIパッケージはオペレーティングシステムのインストールメディアから取得することができます。）</p>\n\n<p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for Red Hat Enterprise Linux 8 Server"},{"lang":"ja","x_late":"HPE Emulexファイバーチャネルイネーブルメントキットforホストバスアダプターおよびメザニンホストバスアダプター - Red Hat Enterprise Linux 8 Server"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4</li>\n</ul>\n\n<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.27"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC firmware running under Microsoft Windows Server 2016, Windows Server 2019 and Windows Server 2022."},{"lang":"ja","x_late":"このパッケージには、Windows Server 2016、Windows Server 2019、およびWindows Server 2022で動作する HPE ProLiant QLogic FastLinQ 10/25/50 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"3121248","datemodified":"2022-02-07T10:20:18","file_list":["cp050214.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.27.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"545102831c61f2560feed2f5540c99ae","name":"cp050214.exe","release":"2022-02-07T10:10:57","revision":"0","sha1sum":"4867b91adcff92f2e48bf712abf3ef78217a1b7e","size":"2MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"dcd60b858b6c4ac298dc49b61299aeb5","version":"545898354c8b4ea5b49e5ae67c7c4d4a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"8.37.37.0","description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<BR>\n<P>From that drive and directory, execute the downloaded file. <BR>\n<P>Click the \"Install\" button to proceed with the installation.</P>\n<P>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</P>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。<BR>\n<P>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<BR>\n<P>［インストール］ボタンをクリックして、インストールを開始します。</P>\n<P>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</P>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for Windows Server x64 Editions"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-03T07:37:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the modification on string format of firmware update payload.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses the problem that the MAC being modified after Firmware update</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"QLBBFWUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"01.75.07"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"01.75.07"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk017507.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"01.75.07"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.05.03"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh020503.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.05.03"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the boot BIOS and firmware of QLogic Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、ブートBIOSとQLogicファイバーチャネルホストバス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"11176914","datemodified":"2021-08-25T09:38:54","file_list":["/CP046820_BUILD_6.data","/CP046820.vmexe","/CP046820.vmexe64","/CP046820.vmfile","/CP046820_VMw.zip","/CP046820.xml","/payload.json","/CP046820_VMw.zip/index.xml","/CP046820_VMw.zip/vendor-index.xml","/CP046820_VMw.zip/metadata.zip","/CP046820_VMw.zip/vib20/CP046820/HPE_bootbank_CP046820_2021.10.01.6-6.5.0.4240417.vib","/CP046820_VMw.zip/metadata.zip/vendor-index.xml","/CP046820_VMw.zip/metadata.zip/vmware.xml","/CP046820_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046820_2021.10.01.6-6.5.0.4240417.xml","/CP046820_VMw.zip/metadata.zip/vibs/CP046820-903880330640096762.xml"],"md5sum":"62f2536b14ba57109e010ad14c6ac5f1","name":"CP046820.zip","release":"2021-08-25T09:33:07","revision":"0","sha1sum":"df6faeb1eb4bcc07e42be65d4677ef2b47f6d2b2","size":"10MB","target_guids":["a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046820","version":"2021.10.01.6-6.5.0.4240417"}]}],"id":{"product":"1d65ef8868044e08a92676108c2b60af","version":"355528fd58c7478788d1eb70381b071a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 6.5"},{"lang":"ja","x_late":"QLogicファイバーチャネルホストバスアダプター for VMware vSphere 6.5用HPEファームウェアフラッシュ"}],"prerequisites":{"required_diskspace":{"size_kb":"2000"},"supported_devices":[{"dev":"2261","subdev":"00FA","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000fa","type":"pci","ven":"1077"},{"dev":"2261","subdev":"00F9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2261159000f9","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0204","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900204","type":"pci","ven":"1077"},{"dev":"2261","subdev":"0203","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-226115900203","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d3","type":"pci","ven":"1077"},{"dev":"2281","subdev":"02D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-2281159002d4","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:52:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>MBI</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 81Q 8Gb PCIe Fibre Channel Host Bus Adapter &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 82Q 8Gb Dual Port PCIe Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 84Q 8Gb Quad Port&nbsp;Fibre Channel Host Bus Adapter&nbsp;</td>\n\t\t\t<td>8Gb</td>\n\t\t\t<td>3.82.00</td>\n\t\t\t<td>8.08.207</td>\n\t\t\t<td>7.00</td>\n\t\t\t<td>3.56</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1000Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>6.04.04</td>\n\t\t\t<td>8.08.232</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.43</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1600Q 32Gb Single Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;SN1600Q 32Gb Dual Port&nbsp;Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>1.75.07</td>\n\t\t\t<td>9.06.02</td>\n\t\t\t<td>7.04</td>\n\t\t\t<td>3.64</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE SN1610Q 32Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td>32Gb</td>\n\t\t\t<td>02.04.07</td>\n\t\t\t<td>09.06.02</td>\n\t\t\t<td>7.11</td>\n\t\t\t<td>0.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Enhancements have been made to the firmware to prevent and better recover from any stoppage as described in Customer Advisory available at <a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us\">https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00094722en_us</a></li>\n\t<li>Fixed a&nbsp;behavior where the number of active Input/Output (IO) exchanges could be reduced under certain fabric conditions, resulting in reduced performance.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">MBI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot Bios</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">1.75.07</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">9.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.04</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">3.64</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610Q 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">02.05.03</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">09.06.02</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">7.11</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">0.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC","sw_key_expectedpath":"firmware:QLOGIC"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the NIC and RoCE drivers for HPE Broadcom NetXtreme-E devices running under VMware vSphere 6.5."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.5下で動作するHPE Broadcom NetXtreme-Eデバイス用のNICおよびRoCEドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains NIC driver version&nbsp;218.0.38.0 and RoCE driver version&nbsp;218.0.16.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、NICドライバーバージョン218.0.38.0とRoCEドライバーバージョン218.0.16.0が含まれています。</p>\n"}],"files":[{"bytes":"342935","datemodified":"2021-09-28T12:20:56","file_list":["/cp049059.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_218.0.38.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_218.0.16.0-1OEM.650.0.0.4598673.vib","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vmware.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtnet--817500090.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/vibs/bnxtroce-2119692319.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtnet-218.0.38.0.xml","/VMW-ESX-6.5.0-bnxt-218.0-1-4564106-offline_bundle-17360326.zip/metadata.zip/bulletins/VMW-ESX-6.5.0-bnxtroce-218.0.16.0.xml"],"md5sum":"f29eab807d35ec64dc1eb0638aed6522","name":"cp049059.zip","release":"2021-09-28T12:16:48","revision":"0","sha1sum":"b2a94276388e6c6d4c0e0802ead0098a70d6bcff","size":"334KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"type_of_change":"0","version":"2021.09.04","vib_list":[{"name":"bnxtnet","version":"218.0.38.0-1OEM.650.0.0.4598673"},{"name":"bnxtroce","version":"218.0.16.0-1OEM.650.0.0.4598673"}]}],"id":{"product":"e382d013e99549e7a97161015561d31e","version":"c55216bb0223418f8bcc1a1e92341fec"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 6.5"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-E ドライバー for VMware vSphere 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1599","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41599","type":"pci","ven":"14E4"},{"dev":"1751","subdev":"1598","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-175114e41598","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-21T01:39:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an issue which Purple Screen Of Death (PSOD) while running &nbsp;Virtual SAN (vSAN) over &nbsp;Remote Direct Memory Access (RDMA) traffic due to invalid Completion Queue Element (CQEs)</p>\n"},{"curr_enhancements_x_late":"<p>This product enhances that additional driver input/output control(ioctl) needed to support Firmware reset/error recovery counters.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"bnxtnet:218.0.38.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"},{"name":"bnxtroce:218.0.16.0-1OEM.650.0.0.4598673","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"586085","datemodified":"2021-08-25T12:15:07","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"md5sum":"e67af058eea4a62b3d40efb716238fb0","name":"elx-lpfc-kmp-default-12.8.528.7_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-08-25T12:08:06","revision":"0","sha1sum":"cd673d98e3432545e73a5a617a5eebbc0355a650","size":"572KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"cf36f8009ed4464f93a208bf9c35b47b","version":"3dedc80d0d244d03bf855f871828fbcb"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh elx-lpfc-kmp-default-12.8.509.3_k5.3.18_51-1.sles15sp3.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n\n<p>Rewrite of same Driver version has to be performed using &ndash;reinstall option</p>\n\n<p>Example: rpm &ndash;Uvh elx-lpfc-kmp-default-&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm &ndash;reinstall</p>\n\n<p>For more information please refer to the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"SUSE Linux Enterprise Server 15 Service Pack 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T09:31:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Added the following:-</strong></p>\n\n<ul>\n\t<li>Added Non-volatile memory express (NVMe) over Fibre Channel (FC) capability</li>\n</ul>\n\n<p>Updated to driver version 12.8.352.11</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"elx-lpfc-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 12 x86_64."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 12 x86_64で動作するHPE QLogic FastLinQ 10/25/50 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"11685436","datemodified":"2021-11-30T06:22:25","file_list":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.50.18.0.bin","./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/4.12.14-120-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"md5sum":"bce8ff553fd7a30c6e83e6c8736edcd2","name":"qlgc-fastlinq-kmp-default-8.55.15.0_k4.12.14_120-1.sles12sp5.x86_64.rpm","release":"2021-11-30T06:08:57","revision":"0","sha1sum":"e58426d0bdfb9731d8addd433c18b96f6cd27276","size":"11MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"type_of_change":"1","version":"8.55.15.0-1"}],"id":{"product":"beee944cb2a04bc7ba023dbf3bec720d","version":"5d790ffb445b4223a2529ff92983c059"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 12 x86_64"},{"lang":"ja","x_late":"SUSE Linux Enterprise Server 12 x86_64用HPE QLogic FastLinQ 10/25/50 GbEドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770074","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770073","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770070","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770069","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770068","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770071","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-807010770072","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0070","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770070","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0069","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770069","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0068","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770068","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0071","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770071","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0072","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770072","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0074","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770074","type":"pci","ven":"1077"},{"dev":"8090","subdev":"0073","subven":"1077","target_guid":"a6b1a447-382a-5a4f-1077-809010770073","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where the 10GbE Adapters having an DNS resolution issue on Kubernetes container-orchestration system</li>\n\t<li>This product addresses an issue where system crashes after PCIe error injection multiple times on HPE SDFlex system</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qlgc-fastlinq-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB2000JFEPA and MB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp; &nbsp; &nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3625168","datemodified":"2021-07-25T14:21:55","file_list":["cp048591.xml","cpqsetup.exe","payload.json","setup.dll","SMKRAND5.rel"],"md5sum":"d87a444bdff88f16ec34fc442f4f815f","name":"cp048591.exe","release":"2021-07-25T14:14:04","revision":"0","sha1sum":"49785077327d36cad0066da95e08a334fc7961ad","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"8fa907efc8b04d69b552ce8d557c6113","version":"6f74e2e043c44b858bb247433fedb732"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T10:05:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD4"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWJNP and EG001200JWJNQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG000600JWJNPおよびEG001200JWJNQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWJNP and EG001200JWJNQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18362615","datemodified":"2021-08-30T04:08:37","file_list":["/CP048251_BUILD_2.data","/CP048251.vmexe","/CP048251.vmexe64","/CP048251.vmfile","/CP048251_VMw.zip","/CP048251.xml","/payload.json","/CP048251_VMw.zip/index.xml","/CP048251_VMw.zip/vendor-index.xml","/CP048251_VMw.zip/metadata.zip","/CP048251_VMw.zip/vib20/CP048251/HPE_bootbank_CP048251_HPD4.2-7.0.0.15843807.vib","/CP048251_VMw.zip/metadata.zip/vendor-index.xml","/CP048251_VMw.zip/metadata.zip/vmware.xml","/CP048251_VMw.zip/metadata.zip/vibs/CP048251--7897607450179728988.xml","/CP048251_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048251_HPD4.2-7.0.0.15843807.xml"],"md5sum":"c6137e820fbc9fd3185720ca1610e637","name":"CP048251.zip","release":"2021-08-30T04:02:58","revision":"0","sha1sum":"640e57fd0cb210cf58a49adab95ca439b53264c9","size":"17MB","target_guids":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048251","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"5829ee37bc994558baa6a98dd52b6154","version":"b899586abb884629b8c51503ec1a593b"},"installation":{"command":"CP041692.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP and EG001200JWJNQ Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWJNPおよびEG001200JWJNQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWJNQ","target_guid":"452340a5-3047-3130-3230-304a574a4e51","type":"sas"},{"id":"EG000600JWJNP","target_guid":"452340a5-3047-3030-3630-304a574a4e50","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T06:49:37","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWJNQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWJNP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH, and MB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) -&nbsp;MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3414744","datemodified":"2021-07-25T12:51:55","file_list":["cp048568.xml","cpqsetup.exe","payload.json","setup.dll","SMBPNTG4.rel"],"md5sum":"dfcf7cbd6ff7d81f137e1510c8d76528","name":"cp048568.exe","release":"2021-07-25T12:44:06","revision":"0","sha1sum":"77016506a76f383e82c5aa2d9cae2a42fd4486ac","size":"3MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"d905350ec9f94f94adf8077625981965","version":"c5fdf202e7b3447999585c0cb3fae9d0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration-line: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T07:27:04","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33602541","datemodified":"2022-03-08T10:52:37","file_list":["payload.json","U31_2.62_03_08_2022.signed.flash","U31_2.62_03_08_2022.xml"],"md5sum":"d5c57d725d9f784940e6f8ac340d3d3e","name":"U31_2.62_03_08_2022.fwpkg","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"bfe73abfe368758578eec2a04105d122c69358f7","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"4de9a363a422456faca983d193ca352a","version":"7ac1e10c5751408fa54a79de5c386709"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>localhost OSの例:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>remote example:<br/><strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:10","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"VMware vSphere 7.0 Fibre Channel NVMe Driver kit for HPE Storage Emulex Mezzanine Host Bus Adapters(HBAs)"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"39264","datemodified":"2021-08-26T11:50:12","file_list":["/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip","/cp046784.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/vib20/brcmnvmefc/EMU_bootbank_brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807.vib","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vendor-index.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vmware.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/vibs/brcmnvmefc--1536773069476625033.xml","/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807_18487972.zip/metadata.zip/bulletins/Broadcom-ELX-brcmnvmefc_12.8.528.7-1OEM.700.1.0.15843807.xml"],"md5sum":"b63f63876fe1ba050974fabab0ea2d9f","name":"cp046784.zip","release":"2021-08-26T11:49:05","revision":"0","sha1sum":"e182af9d1221b9fa6bb837a9663129f9bb15d79a","size":"38KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eccf06fbb4","20a6e8e4-bf33-4c71-a6bf-d9ec8e5a330c"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"brcmnvmefc","version":"12.8.528.7-1OEM.700.1.0.15843807"}]}],"id":{"product":"3e859f26085e4c19bd96948c814343e5","version":"94525b981d91469d99afdc29d8c90ec3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the&nbsp;driver update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware Vsphere Update Manager(VUM) or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on Vsphere Update Manager(VUM) and the esxcli commands</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Storage Emulex Mezzanine Fibre Channel NVMe driver component for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to Driver version 12.8.329.0</p>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to Driver version 12.8.528.7</p>\n\n<p>&nbsp;</p>\n\n<p>This component is supported only on ESXi 7.0U2</p>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"brcmnvmefc:12.8.528.7-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"},{"name":"Broadcom-ELX-brcmnvmefc:12.8.528.7-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOk":true,"FileName":"ilo5_265.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"2.65"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900213","languages":[{"lang":"fr","x_late":"Micrologiciel - Lights-Out Management"},{"lang":"en","x_late":"Firmware - Lights-Out Management"},{"lang":"cn","x_late":"固件 - Lights-Out Management"},{"lang":"tw","x_late":"韌體 ─ Lights─Out 管理"},{"lang":"de","x_late":"Firmware - LOM (Lights-Out Management)"},{"lang":"ko","x_late":"펌웨어 - Lights-Out 관리"},{"lang":"ja","x_late":"ファームウェア - Lights-Outマネジメント"},{"lang":"es","x_late":"Firmware - Administración de apagado eléctrico"}]}],"description":[{"lang":"en","x_late":"This component provides and installs an updated version of firmware for the iLO 5 Management Processor allowing for continued management support of your Server."},{"lang":"ja","x_late":"このコンポーネントは、iLO 5マネジメントプロセッサーがご使用のサーバーを継続して管理サポートできるようアップデートされたバージョンのファームウェアを提供しインストールします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]}],"documentation":[{"lang":"en","x_late":"<p>&nbsp;</p>\n\n<p>iLO&nbsp;5 User Guide and Lights-Out Scripting Guide can also be found by following the links at:<br />\n<br />\n<a href=\"http://www.hpe.com/info/ilo-docs\">http://www.hpe.com/info/ilo-docs</a><br />\n<br />\nSelect your lights-out product, then support &amp; documents, then manuals.<br />\n&nbsp;</p>\n\n<ul>\n\t<li>Check the online help for additional information about how to use features.&nbsp;<br />\n\tOnline help can be accessed from within the browser web pages by clicking the question mark in the upper right-hand corner of each page.</li>\n</ul>\n"}],"files":[{"bytes":"34227648","datemodified":"2022-02-24T05:56:45","file_list":["cp049685.xml","cpqsetup.exe","ilo5_265.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"md5sum":"b09cae8cf30e97c9e2206f5c3c779075","name":"cp049685.exe","release":"2022-02-24T05:54:48","revision":"0","sha1sum":"11467d1ba4884174554ad5b09a8ac1ee131bdc41","size":"32MB","target_guids":["c0bcf2b9-1141-49af-aab8-c73791f0349c"],"type_of_change":"1","version":"2.65"}],"id":{"product":"8384f9a8878649da8d668b07fb30c48e","version":"8340d6afd18e44ec84610fcb163a5780"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE ProLiant Lights-Out Driver must be installed prior to this component "}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Install the firmware using one of these options:</strong></p>\n\n<ul>\n\t<li>Run the Component on the host to be updated.<br />\n\tThe component will update the iLO 5&nbsp;firmware and reset the iLO 5&nbsp;processor.<br />\n\t&nbsp;</li>\n\t<li>Extract the firmware from the component.&nbsp; This will place the firmware image file, iLO5_yyy.bin (where yyy represents the firmware version) in the target directory.&nbsp; You now have these options:\n\t<ul>\n\t\t<li>Login to iLO 5, navigate to the Update Firmware page, and update the firmware from there.</li>\n\t\t<li>Use the HPE Lights-Out Configuration Utility, and RIBCL/XML scripts to update iLO 5&nbsp;across the network.</li>\n\t\t<li>Use the HPE Online Lights-Out Configuration utility, HPONCFG, and RIBCL/XML scripts to update iLO 5&nbsp;from the supported host OS.</li>\n\t\t<li>Use the Directory Migration Utility, contained in the&nbsp;<a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13aa310d9f23432a8d02d5ad56#tab6\">HPE Directories support for Management Processors</a>, &nbsp;The Windows utility supports&nbsp;network discovery of lights-out processors, import/export, as well as bulk firmware update, and does not require directory migration.</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64- HPE Integrated Lights-Out 5"}],"prerequisites":{"required_diskspace":{"size_kb":"5120"},"supported_devices":[{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"},{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"6","minor":"1","name":"Microsoft Windows 7 (64-bit) - All Editions","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows 8.1 (64-bit)","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"2","name":"Microsoft Windows Server 2012","platform":"nt_x86-64","sr":"OEM"},{"edition":"Essentials","major":"6","minor":"2","name":"Microsoft Windows Server 2012 Essentials","platform":"nt_x86-64","sr":"OEM"},{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-18T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Support for Cloud based management with Compute Ops Manager (COM).</li>\n\t<li>Support for Enhanced Download Performance\n\t<ul>\n\t\t<li>This option allows to improve the performance of iLO Scriptable Virtual Media and URL based Firmware update in environments with high network latencies.</li>\n\t</ul>\n\t</li>\n\t<li>Support &nbsp;for NVIDIA A2 PCIE GPU card</li>\n</ul>\n","latest_fixes_x_late":"<p>None</p>\n"},{"curr_enhancements_x_late":"<p>Initial build</p>\n","curr_fixes_x_late":"<p>Initial build</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 System"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U51","value":"HPE ProLiant XL920g Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"RI11","sw_key_expectedpath":"firmware:ilo5"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A42_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"34218056","datemodified":"2022-02-21T05:30:27","file_list":["A42_2.56_02_10_2022.signed.flash","cp050447.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"73d0cbdda7e61977b11e65e5bc6790c7","name":"cp050447.exe","release":"2022-02-21T05:28:39","revision":"0","sha1sum":"7082c2b7e48f60105d9bca55f25b45d509b8216d","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"f74d125372264713b4a9d8ebea70260d","version":"5174c37b8d9641cb8ee79d221421872e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.<br />\n&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。<br />\n </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus（A42）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T07:31:57","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"}],"sw_keys":[{"name":"A42","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U31_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager(SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11268969","datemodified":"2022-03-08T10:55:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/CP051167.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/U31_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051167.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051167.scexe"],"md5sum":"b02ab9cea2b6f3227f1cd591f202b94c","name":"firmware-system-u31-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"d4a45d960c54be23143fbc1a358c6d404e5b4770","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"f5aa8733027b4498a80cd2e690d91986","version":"0eee961ba2594fa68503126003fe9d40"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10（U31）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:12","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"U31","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK3"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK3"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK3"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK3"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK3"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACD6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4140472","datemodified":"2021-08-16T10:59:19","file_list":["cp049282.xml","cpqsetup.exe","payload.json","setup.dll","TACD6ALLGPK3.rel"],"md5sum":"f977c0218aaa038897261b6851b2fd71","name":"cp049282.exe","release":"2021-08-16T10:51:04","revision":"0","sha1sum":"230604df1654239b734f2ec7a1fa5e9847265130","size":"3MB","target_guids":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"b0d91a06dd9c4473a208b93b1c088e41","version":"e8e976885c88449a9c03c7203a6afe4d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCD6XVUL800G、KCD6XVUL1T60、KCD6XVUL3T20、KCD6XVUL6T40、KCD6XVUL12T8、KCD6XLUL960G、KCD6XLUL1T92、KCD6XLUL3T84、KCD6XLUL7T68、KCD6XLUL15T3ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"KCD6XLUL7T68","target_guid":"002340a5-434b-3644-584c-554c37543638","type":"nvme"},{"id":"KCD6XVUL6T40","target_guid":"002340a5-434b-3644-5856-554c36543430","type":"nvme"},{"id":"KCD6XVUL1T60","target_guid":"002340a5-434b-3644-5856-554c31543630","type":"nvme"},{"id":"KCD6XVUL800G","target_guid":"002340a5-434b-3644-5856-554c38303047","type":"nvme"},{"id":"KCD6XVUL3T20","target_guid":"002340a5-434b-3644-5856-554c33543230","type":"nvme"},{"id":"KCD6XVUL12T8","target_guid":"002340a5-434b-3644-5856-554c31325438","type":"nvme"},{"id":"KCD6XLUL960G","target_guid":"002340a5-434b-3644-584c-554c39363047","type":"nvme"},{"id":"KCD6XLUL1T92","target_guid":"002340a5-434b-3644-584c-554c31543932","type":"nvme"},{"id":"KCD6XLUL3T84","target_guid":"002340a5-434b-3644-584c-554c33543834","type":"nvme"},{"id":"KCD6XLUL15T3","target_guid":"002340a5-434b-3644-584c-554c31355433","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T10:43:23","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCD6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL7T68","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL12T8","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL15T3","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCD6XLUL1T92","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11666527","datemodified":"2022-03-08T13:14:12","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/CP051185.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/U34_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051185.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051185.scexe"],"md5sum":"fa7917601b43d1ed51782c78a80e407b","name":"firmware-system-u34-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"df76368ffb8ef8142102548593c035169adbfb62","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"0fb6a42a8b224caba8a145e0ac696d52","version":"7bc9f8d5cdaa471d9f774b35765e0451"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10（U34）サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:50","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.02"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.02"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.19.02"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code, PXE, NCSI, iSCSI, FCoE and CCM code running under Microsoft Windows Server 2016, Windows Server 2019 and Windows Server 2022."},{"lang":"ja","x_late":"このパッケージには、Microsoft Windows Server 2016、Windows Server 2019、およびWindows Server 2022で動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、PXE、NCSI、iSCSI、FCoEおよびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"4097944","datemodified":"2021-12-21T08:08:36","file_list":["cp050211.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.19.02.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"md5sum":"4bbb7fe75b0307d970ab16ce6293bf89","name":"cp050211.exe","release":"2021-12-21T07:59:16","revision":"0","sha1sum":"b5838cb48747525a9cd685f1b756c16a3844f026","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"5.2.6.0"}],"id":{"product":"1e10e20d274448bb9d2d1625880b482d","version":"27bae0cb71be4b93973d0098b57d3d61"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"7.13.165.0","description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the &quot;Install&quot; button to proceed with the installation.</p>\n\n<p>Network connectivity may stop during the upgrade process and may need to be restarted after completion.</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n\n<p>［インストール］ボタンをクリックして、インストールを開始します。</p>\n\n<p>アップグレード中はネットワーク接続が停止し、完了後は再起動が必要になります。</p>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Windows Server x64 Edition"}],"prerequisites":{"required_diskspace":{"size_kb":"5400"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T07:37:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2022.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QlNicFwUpg.exe","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG2"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG2"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG2"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K511HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n\n<p><strong>Known Issues:</strong></p>\n\n<ul>\n\t<li>Restrict to downgrade to HPG1 or HPG0.</li>\n</ul>\n"}],"files":[{"bytes":"9779096","datemodified":"2021-12-20T07:18:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/CP050581.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/K511HPG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050581.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050581.scexe"],"md5sum":"25164b7010923df87e18031ced8f5c43","name":"firmware-hdd-befd42bd64-HPG2-1.1.x86_64.rpm","release":"2021-12-20T07:06:44","revision":"0","sha1sum":"0e13ffc77bcd03b54db2eb6cf50565517992b9eb","size":"9MB","target_guids":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"8f93dddcb15744aab6bb426d5e84dee8","version":"1582fd3986214a31884124ff7ace3185"},"installation":{"command":"CP043255.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl　\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - VK000480GZCNE、VK000960GZCNF、VK001920GZCNHおよびVK003840GZCNKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK000480GZCNE","target_guid":"562340a5-304b-3030-3438-30475a434e45","type":"sata"},{"id":"VK000960GZCNF","target_guid":"562340a5-304b-3030-3936-30475a434e46","type":"sata"},{"id":"VK001920GZCNH","target_guid":"562340a5-304b-3130-3932-30475a434e48","type":"sata"},{"id":"VK003840GZCNK","target_guid":"562340a5-304b-3330-3834-30475a434e4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-20T07:02:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Support new PCB H/W with&nbsp;new temperature sensor.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960GZCNF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GZCNE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GZCNK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001920GZCNH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK3"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK3"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK3"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK3"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK3"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK3"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK3"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"KPE60X1GHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"20609710","datemodified":"2021-08-27T06:43:17","file_list":["/CP048467_BUILD_2.data","/CP048467.vmexe","/CP048467.vmexe64","/CP048467.vmfile","/CP048467_VMw.zip","/CP048467.xml","/payload.json","/CP048467_VMw.zip/index.xml","/CP048467_VMw.zip/vendor-index.xml","/CP048467_VMw.zip/metadata.zip","/CP048467_VMw.zip/vib20/CP048467/HPE_bootbank_CP048467_HPK3.2-7.0.0.15843807.vib","/CP048467_VMw.zip/metadata.zip/vendor-index.xml","/CP048467_VMw.zip/metadata.zip/vmware.xml","/CP048467_VMw.zip/metadata.zip/vibs/CP048467--285366709705387401.xml","/CP048467_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048467_HPK3.2-7.0.0.15843807.xml"],"md5sum":"7645bda5f84987998dbabcbe90261181","name":"CP048467.zip","release":"2021-08-27T06:37:41","revision":"0","sha1sum":"c8eaceba6d5b98fd40abc403fe7c733dd7ab0ad4","size":"19MB","target_guids":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"type_of_change":"2","version":"HPK3","vib_list":[{"name":"CP048467","version":"HPK3.2-7.0.0.15843807"}]}],"id":{"product":"2fa1597649f243c092f040a8ecf90232","version":"a74e0ba192794b24816a4d9330640203"},"installation":{"command":"CP036934.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000800KWWFE、MK001600KWWFF、MK003200KWWFH、MK006400KWWFK、 VK000960KWWFL、VK001920KWWFN、 VK003840KWWFPおよびVK007860KWWFQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK007680KWWFQ","target_guid":"562340a5-304b-3730-3638-304b57574651","type":"nvme"},{"id":"MK006400KWWFK","target_guid":"4d2340a5-304b-3630-3430-304b5757464b","type":"nvme"},{"id":"VK003840KWWFP","target_guid":"562340a5-304b-3330-3834-304b57574650","type":"nvme"},{"id":"MK003200KWWFH","target_guid":"4d2340a5-304b-3330-3230-304b57574648","type":"nvme"},{"id":"VK001920KWWFN","target_guid":"562340a5-304b-3130-3932-304b5757464e","type":"nvme"},{"id":"MK001600KWWFF","target_guid":"4d2340a5-304b-3130-3630-304b57574646","type":"nvme"},{"id":"VK000960KWWFL","target_guid":"562340a5-304b-3030-3936-304b5757464c","type":"nvme"},{"id":"MK00800KWWFE","target_guid":"002340a5-4b4d-3030-3830-304b57574645","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T13:21:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This FW change resolves a MCTP VDM compliance issue seen by iLO version 2.30.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00111061en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840KWWFP","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWWFF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWWFE","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK003200KWWFH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK007680KWWFQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWWFN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000960KWWFL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK006400KWWFK","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK3"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK3"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK3"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK3"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK3"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK3"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK3"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TACM6ALLGPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD Flash Component for Windows&nbsp;(x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68&nbsp; Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>GPK3</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4148688","datemodified":"2021-08-16T11:47:36","file_list":["cp049285.xml","cpqsetup.exe","payload.json","setup.dll","TACM6ALLGPK3.rel"],"md5sum":"ea23a72233b293e36e748b6ae241e145","name":"cp049285.exe","release":"2021-08-16T11:38:27","revision":"0","sha1sum":"33b15a80d2835e31c30c1c3c16147060f0241d59","size":"3MB","target_guids":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"type_of_change":"1","version":"GPK3"}],"id":{"product":"ffbc55840f92498790e9569c6abb14d8","version":"ba5632b2c2b346dcb550c249a320af33"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するには</strong><a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: blue; text-decoration: none;\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - KCM6XVUL800G、KCM6XVUL1T60、KCM6XVUL3T20、KCM6XVUL6T40、KCM6XRUL960G、KCM6XRUL1T92、KCM6XRUL3T84、KCM6XRUL7T68ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"KCM6XRUL960G","target_guid":"002340a5-434b-364d-5852-554c39363047","type":"nvme"},{"id":"KCM6XRUL7T68","target_guid":"002340a5-434b-364d-5852-554c37543638","type":"nvme"},{"id":"KCM6XRUL1T92","target_guid":"002340a5-434b-364d-5852-554c31543932","type":"nvme"},{"id":"KCM6XVUL3T20","target_guid":"002340a5-434b-364d-5856-554c33543230","type":"nvme"},{"id":"KCM6XRUL3T84","target_guid":"002340a5-434b-364d-5852-554c33543834","type":"nvme"},{"id":"KCM6XVUL800G","target_guid":"002340a5-434b-364d-5856-554c38303047","type":"nvme"},{"id":"KCM6XVUL6T40","target_guid":"002340a5-434b-364d-5856-554c36543430","type":"nvme"},{"id":"KCM6XVUL1T60","target_guid":"002340a5-434b-364d-5856-554c31543630","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-16T11:27:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This Firmware release address below&nbsp;fixes and additional features:</p>\n\n<ul>\n\t<li>FW Transfer Fix</li>\n\t<li>Drive Failure Fix</li>\n\t<li>Power Loss Protection</li>\n\t<li>FW Download Fix</li>\n\t<li>Reset Fix</li>\n\t<li>Shutdown fix</li>\n\t<li>PCIe Improvement</li>\n\t<li>Random Write Improvement</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"KCM6XVUL6T40","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL1T92","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL800G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL3T20","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL3T84","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XVUL1T60","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL960G","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"KCM6XRUL7T68","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB002000JWFVN and MB004000JWFVP&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"4891151","datemodified":"2021-07-23T08:07:28","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/CP048097.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/TATCATRsnSD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d7af557f47-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048097.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048097.scexe"],"md5sum":"a5f0ec10d093c5076c6a1a67621f90f0","name":"firmware-hdd-d7af557f47-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:54:07","revision":"0","sha1sum":"7fd94b760930ba104f945014e32a737472aac292","size":"4MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"f1e144df7ff3445292cda5ea1ed9d30c","version":"cbb50abb426344279a81c407c3d58469"},"installation":{"command":"CP041753.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/jp/servers/spp_dl\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB002000JWFVNおよびMB004000JWFVP ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:44:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"218.0.303000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"bcm218.0.303000.Optimized.pup.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"218.0.303000"}]},"PackageFormat":"FWPKG-v2","Type":"ComboFirmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Broadcom NetXtreme-E Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Broadcom NetXtreme-E Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains NVM Image version 218.0.303000 with the following firmware versions:</p>\n\n<ul>\n\t<li>Bootcode Version: 218.0.229.0</li>\n\t<li>NCSI Version: 218.0.173.0</li>\n\t<li>MBA Version:&nbsp;218.0.38.0</li>\n\t<li>UEFI Version:&nbsp;218.0.93.0</li>\n\t<li>CCM Version:&nbsp;218.0.28.0</li>\n\t<li>RoCE Version:&nbsp;218.0.5.0</li>\n</ul>\n"}],"files":[{"bytes":"8429236","datemodified":"2022-01-27T02:26:12","file_list":["bcm218.0.303000.Optimized.pup.HPb","bcm218.0.303000.Optimized.pup.xml","payload.json"],"md5sum":"186b54ec188bf4da7b98bf5ebdb47aae","name":"bcm218.0.303000.Optimized.pup.fwpkg","release":"2022-01-27T02:21:56","revision":"0","sha1sum":"01d901d53e7723994de37bfcd243f8bd2c4a59c3","size":"8MB","target_guids":["a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16d815900212"],"type_of_change":"1","version":"218.0.303000"}],"id":{"product":"8d2bd99747b540d2a364efef8e58a91c","version":"989ee891e1ee4e8cace95faea68f9953"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n\t<li>\n\t<p>Be noted that it needs the minimum version(NVM Image version 216.0.333011) for this firmware package, please refer to the following link to update firmware first.</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c9c99d62694e4a6aa418b0a781\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c9c99d62694e4a6aa418b0a781</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_2502ce87e3ba481081daea7a6c\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_2502ce87e3ba481081daea7a6c</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_0d5f5f72693848838710781e5e\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_0d5f5f72693848838710781e5e</a></p>\n\n\t<p>&nbsp;</p>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n\t<li>\n\t<p>このファームウェアパッケージには最小バージョン（NVMイメージバージョン216.0.333011）が必要であることに注意してください。最初にファームウェアをアップデートするには、次のリンクを参照してください。</p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c9c99d62694e4a6aa418b0a781\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_c9c99d62694e4a6aa418b0a781</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_2502ce87e3ba481081daea7a6c\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_2502ce87e3ba481081daea7a6c</a></p>\n\n\t<p><a href=\"https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_0d5f5f72693848838710781e5e\" style=\"color:#0563c1; text-decoration:underline\">https://support.hpe.com/hpesc/public/swd/detail?swItemId=MTX_0d5f5f72693848838710781e5e</a></p>\n\n\t<p> </p>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters"},{"lang":"ja","x_late":"HPE Broadcom NetXtreme-Eファームウェアパッケージfor BCM5741xアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"16D7","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d715900211","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d71590020e","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d815900212","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d81590020c","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c3","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16d7159002c5","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee15900212","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ee1590020c","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec15900211","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec1590020e","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"0212","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef15900212","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"020C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ef1590020c","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"0211","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed15900211","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"020E","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed1590020e","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c3","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ec159002c5","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c3","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"02C5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ed159002c5","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-22T05:25:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where network interface could not be brought up under VMWare.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue a packet missing problem after some amounts of multicast UDP streams transmitted.</li>\n\t<li>This product addresses an issue the port identifier LED problem on HPE Ethernet 10Gb 2-port 535T Adapter .</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL388 Gen10 Server"}],"sw_keys":[{"name":"NIC_NXE_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Intel i40ea Gigabit Ethernet NICs running under Microsoft Windows Server 2019."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1144392","datemodified":"2021-07-23T15:03:39","file_list":["cp047040.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"md5sum":"70c00cf5e07bb2d3e1a5874a9a840f59","name":"cp047040.exe","release":"2021-07-23T14:50:04","revision":"0","sha1sum":"4e0853e3a010c6e7a8468ce04f4b1c9c8d4926da","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"type_of_change":"0","version":"1.16.62.0"}],"id":{"product":"6510bb61b44e4df589649e5642d32bf1","version":"f046d35c19254fce88771d3ea1a13b4f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel i40ea Driver for Windows Server 2019"}],"prerequisites":{"required_diskspace":{"size_kb":"3200"},"supported_devices":[{"dev":"1572","subdev":"0008","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-157280860008","type":"pci","ven":"8086"},{"dev":"1572","subdev":"00A1","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-1572808600a1","type":"pci","ven":"8086"},{"dev":"1572","subdev":"0000","subven":"8086","target_guid":"","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects an traffic packets making cert failure seen when packets transferred to VLAN after RDMA function enabled.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"i40ea68.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4899291","datemodified":"2021-07-23T07:20:23","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/CP048138.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/TAMG07abHPG7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b78255e146-HPG7-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048138.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048138.scexe"],"md5sum":"1d72c47b26f6da4a002c920bc352a04a","name":"firmware-hdd-b78255e146-HPG7-3.1.x86_64.rpm","release":"2021-07-23T07:08:11","revision":"0","sha1sum":"4b6111549d4231150160d12d4c580bed3f83e00d","size":"4MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7"}],"id":{"product":"03a1d5d1c9c84f2b9c715674a729ac00","version":"ec43d5dfea664a0aab8c044594f7bc4a"},"installation":{"command":"CP042460.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:09:19","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"VMware ESXi 7.0 Mellanox mst driver for Mellanox devices"},{"lang":"ja","x_late":"VMware ESXi 7.0 Mellanox mstドライバー for Mellanoxデバイス"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"31699","datemodified":"2022-01-28T05:22:32","file_list":["/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip","/cp050896.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/vib20/nmst/MEL_bootbank_nmst_4.14.3.3-1OEM.700.1.0.15525992.vib","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/vibs/nmst-669545082738554545.xml","/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992_16211416.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.14.3.3-1OEM.700.1.0.15525992.xml"],"md5sum":"758feb8c8df5de070b7cc0935122fd30","name":"cp050896.zip","release":"2022-01-28T05:21:09","revision":"0","sha1sum":"c2aa085d36a0598385fdc73c8b5412bc90993ca5","size":"30KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd0345028","20a6e8e4-bf33-4c71-a6bf-d9ec89537299"],"type_of_change":"1","version":"2020.11.11","vib_list":[{"name":"nmst","version":"4.14.3.3-1OEM.700.1.0.15525992"}]}],"id":{"product":"3f367d314e5844f2951b656b04957c6e","version":"8cca317e5e8a49dbba8b3f90c50af577"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Remote Online:&nbsp;</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the HPE USB Key Creator Utility.&nbsp;</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux .</li>\n\t<li>cd /SPP20xxxxx and launch SUM&nbsp;(launch_sum.bat for Windows and ./launch_sum.sh for Linux).</li>\n\t<li>Select &quot;Baseline Library&quot; and wait for the Baseline inventory to complete.</li>\n\t<li>Select &quot;Nodes&quot; from the &quot;Smart Update Manager x.x.x&quot; drop down.</li>\n\t<li>Click, &quot;Add Node&quot;.\n\t<ul>\n\t\t<li>If adding a Gen9 server,\n\t\t<ul>\n\t\t\t<li>Provide IP address of the ESXi host.</li>\n\t\t\t<li>Enter&nbsp;the ESXi host credentials (root or administrator username and password)&nbsp;</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>If adding a Gen10 and above server,\n\t\t<ul>\n\t\t\t<li>Provide iLO IP address of the ESXi host server.</li>\n\t\t\t<li>Enter the iLO credentials of the ESXi host server.</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Follow&nbsp;Smart Update Manager Steps and complete the driver update.&nbsp;</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>リモートオンライン: </strong></p>\n\n<ol>\n\t<li>HPE USB Key Creator Utilityを使用して、SPPをUSBキーにコピーします。 </li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。</li>\n\t<li>cd /SPP20xxxxx およびSUMを起動します。（Windowsの場合はlaunch_sum.bat、Linuxの場合は./launch_sum.sh）</li>\n\t<li>\"ベースラインライブラリ\"を選択し、ベースラインインベントリが完了するのを待ちます。</li>\n\t<li>\"Smart Update Manager x.x.x\"ドロップダウンから\"ノード\"を選択します。</li>\n\t<li>\"ノードの追加\"をクリックします。\n\t<ul>\n\t\t<li>Gen9サーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストのIPアドレスを提供します。</li>\n\t\t\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します </li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>Gen10以降のサーバーを追加する場合、\n\t\t<ul>\n\t\t\t<li>ESXiホストサーバーのiLO IPアドレスを提供します。</li>\n\t\t\t<li>ESXiホストサーバーのiLO認証情報を入力します。</li>\n\t\t</ul>\n\t\t</li>\n\t</ul>\n\t</li>\n\t<li>Smart Update Managerの指示に従い、ドライバーのアップデートを完了します。 </li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li>オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"net-mst kernel module driver component for VMware ESXi 7.0"},{"lang":"ja","x_late":"net-mstカーネルモジュールドライバーコンポーネントfor VMware ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"02C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1017159002c8","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"032D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-10171590032d","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C9","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c9","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0246","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900246","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0346","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900346","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"02C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c7","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D3","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d3","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"00D4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159000d4","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0068","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30068","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0347","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900347","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0345","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900345","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"0348","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b15900348","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0069","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30069","type":"pci","ven":"15B3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"0074","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101b15b30074","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1013","subdev":"0221","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101315900221","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-27T08:03:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>NMST version&nbsp;4.14.3.3</p>\n"},{"curr_enhancements_x_late":"<p>NMST version&nbsp;4.14.3.3</p>\n\n<p>&nbsp;</p>\n\n<p>This version adds support for firmware update on all latest Mellanox adapters including ConnectX6, ConnectX6-Dx and ConnectX6-Lx chipsets based adapters.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE Apollo sx40 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo kl20 Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"","value":"HPE Apollo am35 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo pc40 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"Mellanox-NATIVE-NMST:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"nmst:4.14.3.3-1OEM.700.1.0.15525992","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18324220","datemodified":"2021-08-27T11:41:18","file_list":["/CP048426_BUILD_2.data","/CP048426.vmexe","/CP048426.vmexe64","/CP048426.vmfile","/CP048426_VMw.zip","/CP048426.xml","/payload.json","/CP048426_VMw.zip/index.xml","/CP048426_VMw.zip/vendor-index.xml","/CP048426_VMw.zip/metadata.zip","/CP048426_VMw.zip/vib20/CP048426/HPE_bootbank_CP048426_HPD6.2-7.0.0.15843807.vib","/CP048426_VMw.zip/metadata.zip/vendor-index.xml","/CP048426_VMw.zip/metadata.zip/vmware.xml","/CP048426_VMw.zip/metadata.zip/vibs/CP048426-2406326352364881006.xml","/CP048426_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048426_HPD6.2-7.0.0.15843807.xml"],"md5sum":"dbc67d3ed9a18075f2a574f2544c76a6","name":"CP048426.zip","release":"2021-08-27T11:35:58","revision":"0","sha1sum":"af350f596b8a3506bfea0779bffc2699c92c41b3","size":"17MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048426","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"386eb9df6414454ca63bfe17b21ac760","version":"1ee138f5765c41c49519ba9fed6f5d4f"},"installation":{"command":"CP043259.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor ESXi - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T06:58:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for Intel ice Gigabit Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"480529","datemodified":"2021-08-24T15:35:55","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/ice","./lib/modules/3.10.0-1127.el7.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/71","./usr/lib/.build-id/71/324bd92ad86ea45b11edc3d7fe200022d0a4a5","./usr/share/smartupdate/kmod-ice/component.xml"],"md5sum":"44cf6444f0b2b89587213d67c543945a","name":"kmod-ice-1.6.4-1.rhel7u8.x86_64.rpm","release":"2021-08-24T15:29:05","revision":"0","sha1sum":"91194815fb1dd357f906ac47394b50541df6ee1a","size":"469KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.6.4-1"},{"bytes":"480516","datemodified":"2021-08-24T15:38:34","file_list":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.26.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/ice","./lib/modules/3.10.0-1160.el7.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/be","./usr/lib/.build-id/be/e02c1abf372d0b665d6ce18b34cd225fc9ddb7","./usr/share/smartupdate/kmod-ice/component.xml"],"md5sum":"0bb0c4e5391fc8392ff124cf6f34dbdb","name":"kmod-ice-1.6.4-1.rhel7u9.x86_64.rpm","release":"2021-08-24T15:29:05","revision":"0","sha1sum":"5e7d2d24efafcb200d9ad424a6686a7f2c11fdc7","size":"469KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"type_of_change":"1","version":"1.6.4-1"}],"id":{"product":"135fbac0d7a84efa836242f604b0b9bc","version":"72e35f1d9c5c4845baedea8213657e05"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"Intel ice Drivers for  Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"},{"name":"kmod-ice","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D2500sb Storage Blade","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"She-202.fuf.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd185e7afbef","Version":"2.02"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Online Smart Component which upgrades the enclosure Expander firmware on HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"HPE D2500sbストレージブレードのエンクロージャーエキスパンダーファームウェアをアップグレードするオンラインSmartコンポーネントです"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.02&nbsp;<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n\t<li>Added support for Microsoft&nbsp;Windows Server 2019 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：</strong><br />\n     オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE D2500sbストレージブレード用HPE SASエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     2.02 <br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン:</strong><br />\n     2.00<br />\n<br />\n<strong>前のファームウェアバージョン:</strong><br />\n     2.00<br />\n<br />\n<strong>ファームウェアの関連性:</strong><br />\n      なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>ベイ1〜10の場合、電源を入れ直した後、またはホットプラグ後にハードドライブが表示されない場合があります</li>\n\t<li>Microsoft Windows Server 2019 OSのサポートを追加しました。</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p>      なし</p>\n\n<p><strong>既知の問題点:</strong><br />\n      なし</p>\n"}],"files":[{"bytes":"2560000","datemodified":"2019-10-16T11:02:49","file_list":["cp041631.xml","cpqsetup.exe","payload.json","setup.dll","She-202.fuf.fw"],"md5sum":"c1156e1ed159487833ffb7d526a3407c","name":"cp041631.exe","release":"2020-02-12T00:00:00","revision":"1","sha1sum":"28774aa8152fdcecadcaf2c4ad037bc297b7c9ed","size":"2MB","target_guids":["b99dfb74-f0bc-464f-b418-cd185e7afbef"],"type_of_change":"1","version":"2.02"}],"id":{"product":"4bce5935b1b945eda51c9496e5f772b8","version":"1a3e9a68bf1648609b05efb663169795"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a><strong>:</strong></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントをテンポラリディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a><strong></strong></strong>から以下の手順に従ってください：</p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにあるlaunch_hpsum.batスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE SAS Expander Firmware for HPE D2500sb Storage Blade"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows (x64) - HPE D2500sbストレージブレード用HPE SASエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"id":"D2500sb","target_guid":"b99dfb74-f0bc-464f-b418-cd185e7afbef","type":"sas"},{"dev":"028F","subdev":"0609","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0609","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-05T03:20:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Hard drives may not&nbsp;show up after a power cycle or hot plug when in bays 1 through 10</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"D2500sb","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.27"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.27"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.27.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic FastLinQ Gigabit Ethernet NIC firmware running under VMware vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、VMware vSphere 6.5、6.7、および7.0で動作するHPE ProLiant QLogic FastLinQ Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"21026016","datemodified":"2022-02-07T10:16:33","file_list":["/CP050213_BUILD_10.data","/CP050213.vmexe","/CP050213.vmexe64","/CP050213.vmfile","/CP050213_VMw.zip","/CP050213.xml","/payload.json","/CP050213_VMw.zip/index.xml","/CP050213_VMw.zip/vendor-index.xml","/CP050213_VMw.zip/CP050213-build-metadata.zip","/CP050213_VMw.zip/vib20/CP050213/HPE_bootbank_CP050213_4.15.1.10-7.0.0.15843807.vib","/CP050213_VMw.zip/CP050213-build-metadata.zip/vendor-index.xml","/CP050213_VMw.zip/CP050213-build-metadata.zip/vmware.xml","/CP050213_VMw.zip/CP050213-build-metadata.zip/vibs/CP050213-8519191970443955038.xml","/CP050213_VMw.zip/CP050213-build-metadata.zip/bulletins/Smart-Component-CP050213_4.15.1.10-7.0.0.15843807.xml"],"md5sum":"7e5636f884dd2887dfcc1f7524da75d0","name":"CP050213.zip","release":"2022-02-07T10:09:28","revision":"0","sha1sum":"161a7a736b4f96fb82f29cc7d75bea4328eb651d","size":"20MB","target_guids":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"type_of_change":"1","version":"4.15.1","vib_list":[{"name":"CP050213","version":"4.15.1.10-7.0.0.15843807"}]}],"id":{"product":"f68792033b364ab4b274dc849cf93dea","version":"a02f959927174ea7a5989773419b1d19"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p>手動によるインストール手順：</p>\n\n<ol>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）をESXiホストの空き容量が十分にある場所にコピーします。（例：\"/tmp\"）</li>\n\t<li>手順1でCPxxxxxx.zipファイルがコピーされた場所に移動します。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします。</li>\n\t<li>VMwareコンポーネントをインストールします。\n\t<ul>\n\t\t<li>a. ESXi 7.0ターゲットの場合：esxcli software component apply –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software component apply –d /tmp/CPxxxxxx_VMware.zip\"）</li>\n\t\t<li>b. ESXi 6.xターゲットの場合：esxcli software vib install –d <fully_qualified_path>/CPxxxxxx_VMw.zip （例：\"esxcli software vib install –d /tmp/CPxxxxxx_VMw.zip\"）</li>\n\t</ul>\n\t</li>\n\t<li>コンポーネントがインストールされている場所に移動します。（例：\"cd /opt/Smart_Component/CPxxxxxx\"）</li>\n\t<li>必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを使用してコンポーネントを実行します。実行が完了すると、フラッシュエンジンが指示どおりにフラッシュ操作を実行します。</li>\n\t<li>Smartコンポーネントをクリーンアップします。\n\t<ul>\n\t\t<li>a. /opt/Smart_Component/CPxxxxxから別の場所に移動します。（例：\"/tmp\"）</li>\n\t\t<li>b. Smartコンポーネントをクリーンアップするには：\n\t\t<ul>\n\t\t\t<li>i. ESXi 7.0ターゲットの場合：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii. ESXi 6.xターゲットの場合：esxcli software vib remove –n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c. CPxxxxxxに関連付けられているディレクトリを削除します：rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのインストールを完了するために再起動が必要な場合は、システムを再起動します。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE QLogic FastLinQ 上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE QLogic FastLinQ 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware 版 HPE QLogic FastLinQ 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic FastLinQオンラインファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"8070","subdev":"021D","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021d","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021F","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021f","type":"pci","ven":"1077"},{"dev":"8070","subdev":"0220","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-807015900220","type":"pci","ven":"1077"},{"dev":"8070","subdev":"02BD","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-8070159002bd","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021a","type":"pci","ven":"1077"},{"dev":"8070","subdev":"021B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-80701590021b","type":"pci","ven":"1077"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-01-03T07:37:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where the modification on string format of firmware update payload.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses the problem that the MAC being modified after Firmware update</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"}],"sw_keys":[{"name":"QLOGIC_FLQ","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U41_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、HP Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11420584","datemodified":"2022-03-08T14:18:18","file_list":["cp051331.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_2.62_03_08_2022.signed.flash"],"md5sum":"a2a105021bbd28a16282051ea97e80ff","name":"cp051331.exe","release":"2022-03-08T14:16:59","revision":"0","sha1sum":"bc750309e2d2f8144321dac5d2e3bd1f33ab414d","size":"10MB","target_guids":["00000000-0000-0000-0000-000000000216"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"009bd5d739814a67a018565d835c45f1","version":"0853375ba3df423388d29faeac74e69b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - HPE ProLiant ML350 Gen10 (U41) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-07T08:10:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"}],"sw_keys":[{"name":"U41","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A46_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33841194","datemodified":"2022-02-21T12:48:16","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/A46_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/CP050502.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050502.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050502.scexe"],"md5sum":"15de4049df7e4bfbc3c434fd558fc566","name":"firmware-system-a46-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T12:42:01","revision":"0","sha1sum":"59af77a568aa7eb357469039e2825130abc1e0d4","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000229"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"871bd1fc79994166a0695e4fb3b5fd65","version":"1903bf2f527c4404ae4e9123e1599d3a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL225n Gen10 Plus (A46) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T17:19:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"}],"sw_keys":[{"name":"A46","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7555776","datemodified":"2021-07-24T10:35:50","file_list":["cp048685.xml","cpqsetup.exe","GP173500HPK5.rel","payload.json","setup.dll"],"md5sum":"1df1a04aac60ed58a810c16ff285d4e1","name":"cp048685.exe","release":"2021-07-24T10:28:11","revision":"0","sha1sum":"99668f3a204e4064f95692462df92b3f625eb6a5","size":"7MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"7f41af98f1f247caa57376b98f09238f","version":"3b04b64a05324f309e69ac9506292745"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:33:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK0960GECQK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GSV843G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3936-30474543514b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MK0960GECQK"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MK0960GECQK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong>None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"15633440","datemodified":"2021-08-27T05:58:28","file_list":["/CP048387_BUILD_2.data","/CP048387.vmexe","/CP048387.vmexe64","/CP048387.vmfile","/CP048387_VMw.zip","/CP048387.xml","/payload.json","/CP048387_VMw.zip/index.xml","/CP048387_VMw.zip/vendor-index.xml","/CP048387_VMw.zip/metadata.zip","/CP048387_VMw.zip/vib20/CP048387/HPE_bootbank_CP048387_HPG3.2-7.0.0.15843807.vib","/CP048387_VMw.zip/metadata.zip/vendor-index.xml","/CP048387_VMw.zip/metadata.zip/vmware.xml","/CP048387_VMw.zip/metadata.zip/vibs/CP048387-7221830640815724014.xml","/CP048387_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048387_HPG3.2-7.0.0.15843807.xml"],"md5sum":"4ebc221f0691ab8a84391eaf02ccb84d","name":"CP048387.zip","release":"2021-08-27T05:52:45","revision":"0","sha1sum":"3977c595c5af8af4659be7cc37f5a2a7723e0c4f","size":"14MB","target_guids":["002340a5-4d00-304b-3936-30474543514b"],"type_of_change":"2","version":"HPG3","vib_list":[{"name":"CP048387","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"fbb06cc4248449e08cfdf0ed7c07c5e1","version":"9e59777e9fa4416babfe866bc3c92b97"},"installation":{"command":"CP042541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MK0960GECQK Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MK0960GECQKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MK0960GECQK","target_guid":"002340a5-4d00-304b-3936-30474543514b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T10:03:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Firmware fixes intermittent data corruption issue associated with unaligned sequential write operations.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK0960GECQK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEBTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAHC6FG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745425450","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEBTP Drives"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB6000GEBTPドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB6000GEBTP Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG3<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5091034","datemodified":"2021-07-23T07:29:57","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/CP048166.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/HAHC6FG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3243fce9a0-HPG4-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048166.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048166.scexe"],"md5sum":"0a0a610074cf03e288b061732e3ffe9b","name":"firmware-hdd-3243fce9a0-HPG4-9.1.x86_64.rpm","release":"2021-07-23T07:16:15","revision":"0","sha1sum":"4ab79bd9a7f90f838401643faa8e131437fd5613","size":"4MB","target_guids":["002340a5-4d00-3642-3030-304745425450"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"aa6bec5edbc1481bba28cd93023707d3","version":"d54a59d54d24464dac315fcacdc6bc1a"},"installation":{"command":"CP040321.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB6000GEBTP Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB6000GEBTPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB6000GEBTP","target_guid":"002340a5-4d00-3642-3030-304745425450","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:35:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEBTP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 330i Adapter (22BD)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//330i-2x1G-14E4-1665-103C-22BD.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1665103C22BD","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.19.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.19.51"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant Broadcom NX1 Gigabit Ethernet NICs Boot code, PXE, NCSI, and CCM code running under vSphere 6.5, 6.7, and 7.0."},{"lang":"ja","x_late":"このパッケージには、vSphere 6.5、6.7、および7.0で動作するHPE ProLiant Broadcom NX1 Gigabit Ethernet NICブートコード、PXE、NCSI、およびCCMコードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7552182","datemodified":"2022-01-24T10:01:35","file_list":["/CP050425_BUILD_7.data","/CP050425.vmexe","/CP050425.vmexe64","/CP050425.vmfile","/CP050425_VMw.zip","/CP050425.xml","/payload.json","/CP050425_VMw.zip/index.xml","/CP050425_VMw.zip/vendor-index.xml","/CP050425_VMw.zip/metadata.zip","/CP050425_VMw.zip/vib20/CP050425/HPE_bootbank_CP050425_1.30.0.7-7.0.0.15843807.vib","/CP050425_VMw.zip/metadata.zip/vendor-index.xml","/CP050425_VMw.zip/metadata.zip/vmware.xml","/CP050425_VMw.zip/metadata.zip/vibs/CP050425-6450167416201589553.xml","/CP050425_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050425_1.30.0.7-7.0.0.15843807.xml"],"md5sum":"e671b15d717f704a33cbd08b00b4c7ee","name":"CP050425.zip","release":"2022-01-24T10:00:27","revision":"0","sha1sum":"bdc459d254b5ddd85529f9097f9b133012248914","size":"7MB","target_guids":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-1665103C22BD","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"type_of_change":"1","version":"1.30.0","vib_list":[{"name":"CP050425","version":"1.30.0.7-7.0.0.15843807"}]}],"id":{"product":"1a455792d85d4dea8d7373fc92fb5b20","version":"1c4af72a4ed847a29512929d0d5f87f1"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"6.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"3.137e-3","description":"HP Broadcom tg3 Ethernet Driver version 3.137e-3 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Manual installation instructions:</p>\n\n<ol>\n\t<li>Copy the Smart Component (CPxxxxxx.zip) to the ESXi host to a location with plenty of free space. (Example: &quot;/tmp&quot;)</li>\n\t<li>Navigate to the location where the CPxxxxxx.zip file was copied in step 1.</li>\n\t<li>Unzip the CPxxxxxx.zip file.</li>\n\t<li>Install the VMware component.\n\t<ul>\n\t\t<li>a. For ESXi 7.0 targets: esxcli &nbsp;software component apply &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software component apply &ndash;d /tmp/CPxxxxxx_VMware.zip&quot;)</li>\n\t\t<li>b. For ESXi 6.x targets: esxcli software vib install &ndash;d &lt;fully_qualified_path&gt;/CPxxxxxx_VMw.zip. (Example: &quot;esxcli software vib install &ndash;d /tmp/CPxxxxxx_VMw.zip&quot;)</li>\n\t</ul>\n\t</li>\n\t<li>.Navigate to the location where the component is installed. (Example: &quot;cd /opt/Smart_Component/CPxxxxxx&quot;)</li>\n\t<li>Execute the component with the command set options &nbsp;s, -f, -e, -g, &nbsp;etc. if required. When execution is complete the flash engine will have performed the flash operation as directed.</li>\n\t<li>Clean up the Smart Component:\n\t<ul>\n\t\t<li>a. Navigate out of /opt/Smart_Component/CPxxxxx to some other location. (Example: &quot;/tmp&quot;)</li>\n\t\t<li>b. To clean up the Smart Component:\n\t\t<ul>\n\t\t\t<li>i.For ESXi 7.0 targets: esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t\t\t<li>ii.For ESXi 6.x targets: esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t\t</ul>\n\t\t</li>\n\t\t<li>c.Remove the directories associated with CPxxxxxx: rm -rf /opt/Smart_Component/CPxxxxxx</li>\n\t</ul>\n\t</li>\n\t<li>If reboot is required to complete the firmware installation, reboot your system.</li>\n</ol>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 VMware 的 HPE Broadcom NX1 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE Broadcom NX1 Online Firmware Upgrade Utility for VMware"},{"lang":"ko","x_late":"VMware용 HPE Broadcom NX1 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"VMware版HPE Broadcom NX1在线固件升级实用程序"},{"lang":"ja","x_late":"HPE Broadcom NX1オンライン ファームウェアアップグレードユーティリティ for VMware"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"165F","subdev":"22E8","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c22e8","type":"pci","ven":"14E4"},{"dev":"1665","subdev":"22BD","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1665103c22bd","type":"pci","ven":"14E4"},{"dev":"165F","subdev":"1786","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-165f103c1786","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"169D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c169d","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"3383","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c3383","type":"pci","ven":"14E4"},{"dev":"1657","subdev":"22BE","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-1657103c22be","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T08:56:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports VMware ESXi 7.0 u3</p>\n","latest_fixes_x_late":"<p>This product addresses an issue about lost connection under S5 if adapter was running under 1G.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an abnormal reporting on link status of HPE 331i Adapter under IML log.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"BCM","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PCIGen10_1.0.8ts.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.8"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This component provides updated Advanced Power Capping Microcontroller firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたアドバンスト消費電力上限マイクロコントローラーファームウェアを提供します。さらに、Smart Update Manager(SUM)と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"208384","datemodified":"2021-09-07T03:33:39","file_list":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/CP049261.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/PCIGen10_1.0.8ts.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.0.8-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049261.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049261.scexe"],"md5sum":"0bb9ad1df58362a77f54184669817a59","name":"firmware-powerpic-gen10-1.0.8-1.1.x86_64.rpm","release":"2021-09-07T03:23:10","revision":"0","sha1sum":"0a4698a06cf6cf82721ca41ec0f149da08f9d6b1","size":"203KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.8"}],"id":{"product":"d6cef3e7c9484a989ca5a04fc11b29f2","version":"5c486e37b7d64990996cc376a50c1154"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を見て下さい。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Creator Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュ for Linux - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Workstation (x86-64)","platform":"red_hat_enterprise_linux_client_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Workstation (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-12T12:28:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (C) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (C) if a previous component revision was used to upgrade the firmware to ver. 1.0.7.This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for Gen10 platforms with Intel Processors or AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Fixed an issue of inaccurate temperature readings when the actual temperature exceeds 100 &deg;C on Proliant Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2022."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2022用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1985072","datemodified":"2021-12-07T11:02:10","file_list":["cp050318.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"384ef5eb67c0034d07685fdc333d5245","name":"cp050318.exe","release":"2021-12-07T10:48:06","revision":"0","sha1sum":"2b8c4db4136e8a2afdbd194e2e1a53d4e89743b2","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"e6bb5c297d78402ab079f188773b5efc","version":"96acd069ea9942faa7b544c50dfec01c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>インストールボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2022"},{"lang":"ja","x_late":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2022"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30117","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30040","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30042","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30102","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30047","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30116","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30052","type":"pci","ven":"15B3"},{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101E","subdev":"0012","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30012","type":"pci","ven":"15B3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"101E","subdev":"0007","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30007","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product correct an issue which cause TCP connection to drop</p>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000GCWLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304743574c54","Version":"HPG4"},{"DeviceName":"MB3000GCWLU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304743574c55","Version":"HPG4"},{"DeviceName":"MB4000GCWLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HMKPB6G4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304743574c56","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB2000GCWLT, MB3000GCWLU and MB4000GCWLV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MB2000GCWLT, MB3000GCWLU&nbsp;and MB4000GCWLV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3328032","datemodified":"2021-07-25T13:10:13","file_list":["cp048574.xml","cpqsetup.exe","HMKPB6G4.rel","payload.json","setup.dll"],"md5sum":"5157c82ceaa3ff681b23b83b07862bae","name":"cp048574.exe","release":"2021-07-25T13:02:04","revision":"0","sha1sum":"f300693b3aa8c95d42c287da230911a2fdb16a9e","size":"3MB","target_guids":["002340a5-4d00-3242-3030-304743574c54","002340a5-4d00-3342-3030-304743574c55","002340a5-4d00-3442-3030-304743574c56"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"451308857c63431786ef6960ba605a64","version":"e154e90d0509411c8f488523ed20281a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB2000GCWLT, MB3000GCWLU and MB4000GCWLV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB2000GCWLT、MB3000GCWLU、およびMB4000GCWLVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB2000GCWLT","target_guid":"002340a5-4d00-3242-3030-304743574c54","type":"sata"},{"id":"MB3000GCWLU","target_guid":"002340a5-4d00-3342-3030-304743574c55","type":"sata"},{"id":"MB4000GCWLV","target_guid":"002340a5-4d00-3442-3030-304743574c56","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T09:09:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000GCWLV","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GCWLT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB3000GCWLU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWAYN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475741594e","Version":"HPG5"},{"DeviceName":"MB008000GWAYL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHHaseFG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-30475741594c","Version":"HPG5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000GWAYN and MB008000GWAYL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG5<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPG4</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18543172","datemodified":"2021-08-26T12:28:13","file_list":["/CP048333_BUILD_2.data","/CP048333.vmexe","/CP048333.vmexe64","/CP048333.vmfile","/CP048333_VMw.zip","/CP048333.xml","/payload.json","/CP048333_VMw.zip/index.xml","/CP048333_VMw.zip/vendor-index.xml","/CP048333_VMw.zip/metadata.zip","/CP048333_VMw.zip/vib20/CP048333/HPE_bootbank_CP048333_HPG5.2-7.0.0.15843807.vib","/CP048333_VMw.zip/metadata.zip/vendor-index.xml","/CP048333_VMw.zip/metadata.zip/vmware.xml","/CP048333_VMw.zip/metadata.zip/vibs/CP048333-362057173162210721.xml","/CP048333_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048333_HPG5.2-7.0.0.15843807.xml"],"md5sum":"dc0e8a643eb9956977dbe83dedb5aa3b","name":"CP048333.zip","release":"2021-08-26T12:23:20","revision":"0","sha1sum":"cd8fd27f2eed521334bfac8d111c29bdf9b506fd","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-30475741594e","4d2340a5-3042-3830-3030-30475741594c"],"type_of_change":"2","version":"HPG5","vib_list":[{"name":"CP048333","version":"HPG5.2-7.0.0.15843807"}]}],"id":{"product":"d31e8e30285a40108d05d6b3dc709695","version":"139c07b1e0af4fcd87a87d9e7a0608e1"},"installation":{"command":"CP040638.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000GWAYN and MB008000GWAYL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000GWAYNおよびMB008000GWAYLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000GWAYN","target_guid":"4d2340a5-3042-3031-3030-30475741594e","type":"sata"},{"id":"MB008000GWAYL","target_guid":"4d2340a5-3042-3830-3030-30475741594c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:22:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>This code corrects a potential data integrity issue related to unaligned write commands.  This issue was only found in supplier ongoing lab testing.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>\n\t<p>This code corrects a potential data integrity issue related to unaligned write commands.This issue was only found in supplier ongoing lab testing.</p>\n\t</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000GWAYN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWAYL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0600JEMCV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a454d4356","Version":"HPD6"},{"DeviceName":"EG1200JEMDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a454d4441","Version":"HPD6"},{"DeviceName":"EG0300JFCKA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a46434b41","Version":"HPD6"},{"DeviceName":"EG0900JFCKB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"STHBTND6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a46434b42","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB&nbsp;and EG1200JEMDA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3658200","datemodified":"2021-07-24T06:47:25","file_list":["cp048483.xml","cpqsetup.exe","payload.json","setup.dll","STHBTND6.rel"],"md5sum":"dded403e19e35908a7823652d1cd5f7b","name":"cp048483.exe","release":"2021-07-24T06:40:05","revision":"0","sha1sum":"3a5ac6c08a15661e776d6288f1450f09edd9c6f6","size":"3MB","target_guids":["002340a5-4500-3047-3630-304a454d4356","002340a5-4500-3147-3230-304a454d4441","002340a5-4500-3047-3330-304a46434b41","002340a5-4500-3047-3930-304a46434b42"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"935cb1f792604e6aaead9dbf6e50463c","version":"e7d22503884c4dfa920c6700e634ca14"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EG0300JFCKA, EG0600JEMCV, EG0900JFCKB and EG1200JEMDA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EG0300JFCKA、EG0600JEMCV、EG0900JFCKB、およびEG1200JEMDAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EG1200JEMDA","target_guid":"002340a5-4500-3147-3230-304a454d4441","type":"sas"},{"id":"EG0300JFCKA","target_guid":"002340a5-4500-3047-3330-304a46434b41","type":"sas"},{"id":"EG0600JEMCV","target_guid":"002340a5-4500-3047-3630-304a454d4356","type":"sas"},{"id":"EG0900JFCKB","target_guid":"002340a5-4500-3047-3930-304a46434b42","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T06:06:44","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG1200JEMDA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEMCV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0900JFCKB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JFCKA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the iSCSI driver for the HPE Blade Emulex 10/20GbE Server Adapters running under VMware vSphere 6.7."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;12.0.1188.0.</p>\n"}],"files":[{"bytes":"3564592","datemodified":"2019-10-24T14:37:29","file_list":["/cp039935.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/elxiscsi-12.0.1188.0-1OEM.670.0.0.8169922.x86_64.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/ELX-ESX-libelxima-8169922.so-12.0.1188.0.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/README.txt","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/doc/release_note_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elxiscsi/EMU_bootbank_elxiscsi_12.0.1188.0-1OEM.670.0.0.8169922.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/vib20/elx-esx-libelxima-8169922.so/ELX_bootbank_elx-esx-libelxima-8169922.so_12.0.1188.0-03.vib","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vendor-index.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vmware.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/bulletins/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elx-esx-libelxima-8169922.so-123123855.xml","/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-10198133.zip/VMW-ESX-6.7.0-elxiscsi-12.0.1188.0-offline_bundle-10198133.zip/metadata.zip/vibs/elxiscsi-1258413454.xml"],"md5sum":"ca98f9436ce75271d57af62b5c502ee3","name":"cp039935.zip","release":"2019-10-24T19:37:06","revision":"0","sha1sum":"569d731dd3673ac54bb50ac20a47eccdc7f5a7bc","size":"3MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb358b4ee","20a6e8e4-bf33-4c71-a6bf-d9ecadda42ba"],"type_of_change":"0","version":"2019.12.20","vib_list":[{"name":"elxiscsi","version":"12.0.1188.0-1OEM.670.0.0.8169922"},{"name":"elx-esx-libelxima-8169922.so","version":"12.0.1188.0-03"}]}],"id":{"product":"7cdc9cd1c70149848e6e26c6af8613a5","version":"51005bcbd2fb480a9f049a581ad94152"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"elxiscsi:12.0.1188.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"elx-esx-libelxima-8169922.so:12.0.1188.0-03","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for HPE QLogic NX2 10/20 GbE Multifunction Adapters running under VMware vSphere 6.7."},{"lang":"ja","x_late":"この製品は、VMware vSphere 6.7上で動作するHPE QLogic NX2 10/20 GbEマルチファンクションアダプターのためのドライバーを含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains the following drivers:</p>\n\n<ul>\n\t<li>qfle3, version 1.1.17.0</li>\n\t<li>qcnic, version 1.0.59.0</li>\n\t<li>qfle3i, version 1.1.5.0</li>\n\t<li>qfle3f, version 1.1.25.0</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>この製品には、以下のドライバーが含まれています。</p>\n\n<ul>\n\t<li>qfle3、バージョン1.1.17.0</li>\n\t<li>qcnic、バージョン1.0.59.0</li>\n\t<li>qfle3i、バージョン1.1.5.0</li>\n\t<li>qfle3f、バージョン1.1.25.0</li>\n</ul>\n"}],"files":[{"bytes":"1403141","datemodified":"2021-11-24T06:35:01","file_list":["/cp050055.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/vib20/qfle3f/QLC_bootbank_qfle3f_1.1.25.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/vib20/qfle3i/QLC_bootbank_qfle3i_1.1.5.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/vib20/qfle3/QLC_bootbank_qfle3_1.1.22.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/vib20/qcnic/QLC_bootbank_qcnic_1.0.60.0-1OEM.670.0.0.8169922.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vibs/qfle3f--2870239878310587039.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vibs/qfle3i--6801888692139910757.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vibs/qfle3-2400764342230349501.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/vibs/qcnic-8008209728541727.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922-offline_bundle-18597805.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_2.0.157.0-1OEM.670.0.0.8169922.xml"],"md5sum":"e2275cee979cfdc0b87648c617cce70b","name":"cp050055.zip","release":"2021-11-24T06:30:48","revision":"0","sha1sum":"4452f698307388dcc0cc73062c33039a0e0bf0ed","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"qfle3f","version":"1.1.25.0-1OEM.670.0.0.8169922"},{"name":"qfle3i","version":"1.1.5.0-1OEM.670.0.0.8169922"},{"name":"qfle3","version":"1.1.22.0-1OEM.670.0.0.8169922"},{"name":"qcnic","version":"1.0.60.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"c5169d515a774f51aa01a14f6284794f","version":"d3a2c0004f124ad1b19a9ffebd774544"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>更新対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート：</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"VMware vSphere 6.7用HPE QLogic NX2 10/20 GbEマルチファンクションドライバー"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-24T05:43:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This products enhances the mechanism that collation of data log.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"qcnic:1.0.60.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3i:1.1.5.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3f:1.1.25.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"},{"name":"qfle3:1.1.22.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U56_1.58_01_13_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v1.58 (01/13/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33586253","datemodified":"2022-02-07T08:31:43","file_list":["payload.json","U56_1.58_01_13_2022.signed.flash","U56_1.58_01_13_2022.xml"],"md5sum":"06769666edea8ef4ddc3c52c39145fc6","name":"U56_1.58_01_13_2022.fwpkg","release":"2022-02-07T08:27:53","revision":"0","sha1sum":"3a2144c2f829a1d89a01a9dd80425a2b22404aaa","size":"32MB","target_guids":["00000000-0000-0000-0000-000000000239"],"type_of_change":"2","version":"1.58_01-13-2022"}],"id":{"product":"b0391b3a14de43ee99f90e7fe9de4040","version":"8bc15adaea6a4a5897f71a987234608c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE DL110 Gen10 Plus Telco（U56）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-03T06:56:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"<p>Changed the behavior of Restore Manufacturing Defaults from restoring the settings for UEFI, NICs and RAID cards to UEFI only.</p>\n","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where if the administrator password and power-on password are set, after clearing power-on password, administrator password is also cleared.</p>\n\n<p>Addressed an issue (https://support.hpe.com/hpesc/public/docDisplay?docId=a00119362en_us&amp;docLocale=en_US) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): &quot;System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.&quot;</p>\n\n<p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"FTP","value":"FTP-Only System"}],"sw_keys":[{"name":"U56","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO0400JFFCF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3430-304a46464346","Version":"HPD9"},{"DeviceName":"MO0800JFFCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304f-3830-304a46464348","Version":"HPD9"},{"DeviceName":"MO1600JFFCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a4646434b","Version":"HPD9"},{"DeviceName":"MO3200JFFCL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1635D9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-334f-3230-304a4646434c","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives<br />\n&nbsp;<br />\n<strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD9</p>\n\n<p><strong>Last Recommended or Critical Version:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD8</p>\n\n<p><strong>Previous Version of Firmware:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPD8</p>\n\n<p><strong>Firmware Dependency:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Enhancements/New Features:&nbsp;</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"3213888","datemodified":"2021-07-25T21:25:52","file_list":["cp048661.xml","cpqsetup.exe","GP1635D9.rel","payload.json","setup.dll"],"md5sum":"1b43bd1d2e775b57b697604f87e2002b","name":"cp048661.exe","release":"2021-07-25T21:19:04","revision":"0","sha1sum":"05812158e88bb2d1ad973df2c6e2e182d2de46a9","size":"3MB","target_guids":["002340a5-4d00-304f-3430-304a46464346","002340a5-4d00-304f-3830-304a46464348","002340a5-4d00-314f-3630-304a4646434b","002340a5-4d00-334f-3230-304a4646434c"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"82cd9f1b504a4d3798c759e1d18439aa","version":"1c449022ee8141dcbfc8d60afce022a6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO0400JFFCF, MO0800JFFCH, MO1600JFFCK and MO3200JFFCL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO0400JFFCF、MO0800JFFCH、MO1600JFFCK、およびMO3200JFFCLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO1600JFFCK","target_guid":"002340a5-4d00-314f-3630-304a4646434b","type":"sas"},{"id":"MO0400JFFCF","target_guid":"002340a5-4d00-304f-3430-304a46464346","type":"sas"},{"id":"MO0800JFFCH","target_guid":"002340a5-4d00-304f-3830-304a46464348","type":"sas"},{"id":"MO3200JFFCL","target_guid":"002340a5-4d00-334f-3230-304a4646434c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T05:54:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO0800JFFCH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO3200JFFCL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO0400JFFCF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JFFCK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"9097904","datemodified":"2022-01-26T05:16:03","file_list":["cp050865.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_2.56_01_20_2022.signed.flash"],"md5sum":"a1d00de654c7575fede52af766124187","name":"cp050865.exe","release":"2022-01-26T05:13:56","revision":"0","sha1sum":"9e8bec0c114fa7dab68388c33f3da90656209d10","size":"8MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"321dd379dd1a436ab919b4529b332ece","version":"11e94d3fcc0041b7ad514107034f505a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.      同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.      コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、 Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:22:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A47_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33586754","datemodified":"2022-02-21T12:51:31","file_list":["A47_2.56_02_10_2022.signed.flash","A47_2.56_02_10_2022.xml","payload.json"],"md5sum":"34192cf1cfdce257f62b6e86521f91d4","name":"A47_2.56_02_10_2022.fwpkg","release":"2022-02-21T12:47:48","revision":"0","sha1sum":"109245306f5b318a38aad78da3591dae03b70264","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000022d"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"74593c8509e24398998a42d78a910462","version":"bc191592787d4fda86ce6de862c27f9d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus(A47) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-15T19:42:44","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>- Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"}],"sw_keys":[{"name":"A47","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"106746","datemodified":"2021-01-14T07:43:04","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"723c894499a4e8f2aeeef03e668ae96e","name":"be2net-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"272abfb6425aeb7e814dc4e79f20fb672916c16a","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"105101","datemodified":"2021-01-14T07:33:34","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net-kmp-default/component.xml"],"md5sum":"19be9998bd0254ff12efaf23543c5bab","name":"be2net-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-01-14T07:25:04","revision":"0","sha1sum":"abc97fbd076566d3857ac3a440d19f580ddf404e","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecef4cee29"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"c08d6e9a714b4bcab51975dad9f3ab91","version":"bdc3c603bf5c470b8f6dd68a72671f8f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Emulex 10/20GbE ドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 12 Service Pack 2</p>\n\n<p>This product now supports elx_net_install.sh&nbsp;installation script to install be2net driver on SUSE Linux Enterprise Server 12 Service Pack 1 or later.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7555776","datemodified":"2021-07-24T08:55:23","file_list":["cp048687.xml","cpqsetup.exe","GP173300HPK5.rel","payload.json","setup.dll"],"md5sum":"5750029cb74fca526fd41bba05e41e56","name":"cp048687.exe","release":"2021-07-24T08:48:04","revision":"0","sha1sum":"bc07c7f60abcc5707ae5bee17112e245db800ef5","size":"7MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"f6a0af7aeed5453599816388663b56a0","version":"a29d94b85673418bb8a1d736c44d3a32"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\&lt;SPP root folder&gt;\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>Smart Update Managerを使用するには</strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong></strong>から以下の手順に従ってください:</p>\n\n<ul>\n\t<li>アップデートするファームウェアを\\<SPP root folder>\\packagesディレクトリにコピーします。</li>\n\t<li>SPPのルートフォルダーにある<em>launch_sum.bat</em>スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Windows (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T09:39:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD2"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD2"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD2"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SHPEEVANSSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18373109","datemodified":"2021-08-27T14:02:28","file_list":["/CP049051_BUILD_2.data","/CP049051.vmexe","/CP049051.vmexe64","/CP049051.vmfile","/CP049051_VMw.zip","/CP049051.xml","/payload.json","/CP049051_VMw.zip/index.xml","/CP049051_VMw.zip/vendor-index.xml","/CP049051_VMw.zip/metadata.zip","/CP049051_VMw.zip/vib20/CP049051/HPE_bootbank_CP049051_HPD2.2-7.0.0.15843807.vib","/CP049051_VMw.zip/metadata.zip/vendor-index.xml","/CP049051_VMw.zip/metadata.zip/vmware.xml","/CP049051_VMw.zip/metadata.zip/vibs/CP049051-7251617034724169303.xml","/CP049051_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049051_HPD2.2-7.0.0.15843807.xml"],"md5sum":"e7e92ccbe6a695f82b375bf2224e9dfd","name":"CP049051.zip","release":"2021-08-27T13:57:11","revision":"0","sha1sum":"6d3d2d1156b7742a32a8e328d75e900790ed12f2","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP049051","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"628a576c95694de3aab72daab877bb47","version":"a48e68cb8f5e48ccb6a941df8d4e76f4"},"installation":{"command":"CP040517.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000JWZHA","target_guid":"4d2340a5-3042-3031-3030-304a575a4841","type":"sas"},{"id":"MB012000JWZHB","target_guid":"4d2340a5-3042-3231-3030-304a575a4842","type":"sas"},{"id":"MB016000JWZHE","target_guid":"4d2340a5-3042-3631-3030-304a575a4845","type":"sas"},{"id":"MB014000JWZHC","target_guid":"4d2340a5-3042-3431-3030-304a575a4843","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-20T10:20:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB010000JWZHA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB016000JWZHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB012000JWZHB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB014000JWZHC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO001600KWZQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b575a5150","Version":"HPK5"},{"DeviceName":"MO003200KWZQQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173500HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b575a5151","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MO001600KWZQP and MO003200KWZQQ"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MO001600KWZQPおよびMO003200KWZQQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online NVMe SSD Flash Component for VMware ESXi -&nbsp;MO001600KWZQP and MO003200KWZQQ Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong>&nbsp;</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"25233064","datemodified":"2021-08-27T04:42:23","file_list":["/CP048472_BUILD_1.data","/CP048472.vmexe","/CP048472.vmexe64","/CP048472.vmfile","/CP048472_VMw.zip","/CP048472.xml","/payload.json","/CP048472_VMw.zip/index.xml","/CP048472_VMw.zip/vendor-index.xml","/CP048472_VMw.zip/metadata.zip","/CP048472_VMw.zip/vib20/CP048472/HPE_bootbank_CP048472_HPK5.1-7.0.0.15843807.vib","/CP048472_VMw.zip/metadata.zip/vendor-index.xml","/CP048472_VMw.zip/metadata.zip/vmware.xml","/CP048472_VMw.zip/metadata.zip/vibs/CP048472-6073239970384941838.xml","/CP048472_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048472_HPK5.1-7.0.0.15843807.xml"],"md5sum":"9f6895e9325a87c1871f20c725ed5b83","name":"CP048472.zip","release":"2021-08-27T04:37:35","revision":"0","sha1sum":"64b0cc9c3946908968d9525f3bed055674de534f","size":"24MB","target_guids":["4d2340a5-304f-3130-3630-304b575a5150","4d2340a5-304f-3330-3230-304b575a5151"],"type_of_change":"2","version":"HPK5","vib_list":[{"name":"CP048472","version":"HPK5.1-7.0.0.15843807"}]}],"id":{"product":"bb888c4588ea4d4989702d85035e6fce","version":"0583221447974eefb08fe24dcf0c46b2"},"installation":{"command":"CP040631.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MO001600KWZQP and MO003200KWZQQ Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi  - MO001600KWZQPおよびMO003200KWZQQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO003200KWZQQ","target_guid":"4d2340a5-304f-3330-3230-304b575a5151","type":"nvme"},{"id":"MO001600KWZQP","target_guid":"4d2340a5-304f-3130-3630-304b575a5150","type":"nvme"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T16:45:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul style=\"list-style-type:square\">\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO003200KWZQQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MO001600KWZQP","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD6"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD6"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD6"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD6"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD6"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD6"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TARM5ALSHPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi&nbsp;- VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Reduced the occurrence probability of PMIC busy issue.&nbsp;</li>\n\t<li>Fixed the system data error at the drive power on issue.&nbsp;</li>\n\t<li>When the PLP operation starts, the waiting Unmap request to the 4KB not-aligned host write area is canceled to be able to complete PLP correctly.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"17136466","datemodified":"2021-08-30T08:09:27","file_list":["/CP049363_BUILD_1.data","/CP049363.vmexe","/CP049363.vmexe64","/CP049363.vmfile","/CP049363_VMw.zip","/CP049363.xml","/payload.json","/CP049363_VMw.zip/index.xml","/CP049363_VMw.zip/vendor-index.xml","/CP049363_VMw.zip/metadata.zip","/CP049363_VMw.zip/vib20/CP049363/HPE_bootbank_CP049363_HPD6.1-7.0.0.15843807.vib","/CP049363_VMw.zip/metadata.zip/vendor-index.xml","/CP049363_VMw.zip/metadata.zip/vmware.xml","/CP049363_VMw.zip/metadata.zip/vibs/CP049363-2304080808850321206.xml","/CP049363_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049363_HPD6.1-7.0.0.15843807.xml"],"md5sum":"c0b2931e9cf9d814e3be230a2844e9e2","name":"CP049363.zip","release":"2021-08-30T08:04:16","revision":"0","sha1sum":"13f0d8ed25e7148c8ea7702f29c2b2e6863fbd60","size":"16MB","target_guids":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP049363","version":"HPD6.1-7.0.0.15843807"}]}],"id":{"product":"cf7cb50c769b4b00ab89aa81d9fac797","version":"4e8c9fda9e934fb19bb6436ad7d1746b"},"installation":{"command":"CP041554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします。</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi -  VO000960RWUEV、VO001920RWUFA、VO003840RWUFB、VO007680RWUFC、VO000960RWUFD、VO001920RWUFE およびVO003840RWUFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VO007680RWUFC","target_guid":"562340a5-304f-3730-3638-305257554643","type":"sas"},{"id":"VO003840RWUFF","target_guid":"562340a5-304f-3330-3834-305257554646","type":"sas"},{"id":"VO003840RWUFB","target_guid":"562340a5-304f-3330-3834-305257554642","type":"sas"},{"id":"VO001920RWUFE","target_guid":"562340a5-304f-3130-3932-305257554645","type":"sas"},{"id":"VO001920RWUFA","target_guid":"562340a5-304f-3130-3932-305257554641","type":"sas"},{"id":"VO000960RWUFD","target_guid":"562340a5-304f-3030-3936-305257554644","type":"sas"},{"id":"VO000960RWUEV","target_guid":"562340a5-304f-3030-3936-305257554556","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-26T06:50:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Change Vendor Identification Field (VID data) from &quot;HP&quot; to &quot;HPE&quot;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Reduced the occurrence probability of PMIC busy issue.&nbsp;</li>\n\t<li>Fixed the system data error at the drive power on issue.&nbsp;</li>\n\t<li>When the PLP operation starts, the waiting Unmap request to the 4KB not-aligned host write area is canceled to be able to complete PLP correctly.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO000960RWUFD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO007680RWUFC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO000960RWUEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO003840RWUFF","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"VO001920RWUFE","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U43_2.56_01_20_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v2.56 (01/20/2022)"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"\t\nThis firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"\t\nこのファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアを更新することを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"16815275","datemodified":"2022-01-26T05:20:09","file_list":["payload.json","U43_2.56_01_20_2022.signed.flash","U43_2.56_01_20_2022.xml"],"md5sum":"4f87c9423eff0e3706aff76f5b9766bb","name":"U43_2.56_01_20_2022.fwpkg","release":"2022-01-26T05:14:08","revision":"0","sha1sum":"62adc4d4df3446fd8efdd9427af4f086e5499228","size":"16MB","target_guids":["00000000-0000-0000-0000-000000000218"],"type_of_change":"1","version":"2.56_01-20-2022"}],"id":{"product":"b64e2e4187274c5798b3aa127c50ba6a","version":"ad3061cd81ca4ccbbb3fecdaf4cf6c1e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager(SUM)の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers"},{"lang":"ja","x_late":"ROMフラッシュファームウェアパッケージ - HPE ProLiant DL20 Gen10(U43)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-26T03:22:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes the latest revision of the Intel IPU 2021.2 which provides mitigations for BIOS advisories and security vulnerabilities documented as CVE-2021-0157. These security vulnerabilities are documented in the CVE report site.  This issue is not unique to HPE servers.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2 which provides mitigations for security vulnerabilities CVE-2021-0092, CVE-2021-0127, CVE-2021-0156 and CVE-2021-0157. These issues are not unique to HPE servers.</p><p>Fixed an issue where system boot mode changed to Legacy mode from UEFI mode after IP flash complete and system may hang when entering IP after setting to UEFI mode.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"}],"sw_keys":[{"name":"U43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"CurrentVersionRestriction":">= 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false},{"CurrentVersionRestriction":"< 0.1.4.4","DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"DirectoryScan":false,"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"\n This component provides updated IE firmware that can be installed directly on supported Operating Systems.\n "}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"6492517","datemodified":"2022-02-21T02:11:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/CP051157.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/cp051154.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/cp051154.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/cp051155.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/cp051155.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051157.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051157.scexe"],"md5sum":"553ed589c66ea269d8a932a2c5424a8f","name":"firmware-iegen10-0.2.3.0-1.1.x86_64.rpm","release":"2022-02-21T02:03:16","revision":"0","sha1sum":"da75a89038d275075370a24b3597898ac954d368","size":"6MB","target_guids":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"type_of_change":"0","version":"0.2.3.0"}],"id":{"product":"05f0508175404d989c50e4f9a4e09a23","version":"6ac2a7b741bb40daaa2dd152ee0e48f7"},"installation":{"command":"cpqsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><br />\nTo update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n\n<p>&nbsp;</p>\n\n<ul>\n</ul>\n"},{"lang":"ja","x_late":"<p><br />\nターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで確認したディレクトリに変更し、コマンドプロンプトに‘./hpsetup’を入力して、hpsetupを実行します。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法で更新します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対する更新を実行するためにiLOによってスクリプト化できることに注意してください。</p>\n\n<p> </p>\n\n<ul>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュfor Linux - HPE Gen10イノベーションエンジンファームウェアfor HPE Gen10サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-03-21T01:58:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Address an issue where Innovation Engine (IE) Firmware may be unresponsive and iLO Firmware may report &ldquo;Update Failed&rdquo; after flashing the Innovation Engine (IE) Firmware via RESTful update. &nbsp;The flash will have been performed successfully, but the system must be reset for IE Firmware to function properly.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Addressed an issue where Innovation Engine (IE) may improperly reset every 24 hours.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"IE-Gen10","sw_key_expectedpath":"firmware:sd:ie"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD3"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD3"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD3"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD3"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD3"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD3"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD3"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hbcpssssefd3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル：MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3388568","datemodified":"2021-07-25T17:44:46","file_list":["cp048628.xml","cpqsetup.exe","hbcpssssefd3.rel","payload.json","setup.dll"],"md5sum":"d6324da8b6a43e5a4232ac6b7ab9da3c","name":"cp048628.exe","release":"2021-07-25T17:37:04","revision":"0","sha1sum":"d8e9a4555259977c644a19cda1eaaf86a10bd3c3","size":"3MB","target_guids":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"type_of_change":"1","version":"HPD3"}],"id":{"product":"dab6093d4d7545e892501476a1f6d448","version":"159b88bd8d61468085aeab0d4ce3d5b4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MO000400JWUFT、MO000800JWUFU、MO001600JWUFV、MO003200JWUGA、MO006400JWUGB、EO000400JWUGC、EO000800JWUGD、およびEO001600JWUGEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MO006400JWUGB","target_guid":"4d2340a5-304f-3630-3430-304a57554742","type":"sas"},{"id":"MO003200JWUGA","target_guid":"4d2340a5-304f-3330-3230-304a57554741","type":"sas"},{"id":"MO001600JWUFV","target_guid":"4d2340a5-304f-3130-3630-304a57554656","type":"sas"},{"id":"EO001600JWUGE","target_guid":"452340a5-304f-3130-3630-304a57554745","type":"sas"},{"id":"MO000800JWUFU","target_guid":"4d2340a5-304f-3030-3830-304a57554655","type":"sas"},{"id":"EO000800JWUGD","target_guid":"452340a5-304f-3030-3830-304a57554744","type":"sas"},{"id":"MO000400JWUFT","target_guid":"4d2340a5-304f-3030-3430-304a57554654","type":"sas"},{"id":"EO000400JWUGC","target_guid":"452340a5-304f-3030-3430-304a57554743","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:45:27","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EO000800JWUGD","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JWUGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JWUGE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JWUGC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JWUFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000400JWUFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JWUFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JWUGB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"PCIGen10_1.0.8ts.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.0.8"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900083","languages":[{"lang":"tw","x_late":"韌體 ─ 電源管理"},{"lang":"en","x_late":"Firmware - Power Management"},{"lang":"ko","x_late":"펌웨어 - 전원 관리"},{"lang":"ja","x_late":"ファームウェア - パワー マネジメント"},{"lang":"cn","x_late":"固件 - 电源管理"}]}],"description":[{"lang":"en","x_late":"This firmware package provides updated system firmware that can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update. "},{"lang":"ja","x_late":"このファームウェアパッケージは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOrest)などのツールを使用して、オンラインでインストールできるアップデートされたシステムファームウェアを提供します。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"149607","datemodified":"2021-09-07T03:27:40","file_list":["payload.json","PCIGen10_1.0.8ts.hex","PICGen10-1.0.8-1.xml"],"md5sum":"505921f7426067a0a504d4681eb9c0a8","name":"PICGen10-1.0.8-1.fwpkg","release":"2021-09-07T03:23:40","revision":"0","sha1sum":"8f1d894b028e7a9b90824824ad8faff72c5d0de8","size":"146KB","target_guids":["00000000-0000-0000-0000-000000504d05"],"type_of_change":"0","version":"1.0.8"}],"id":{"product":"fae7c963a551489594d913b81c29f2a4","version":"5312b21ca0ee4a07905032aa384ffeca"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":60,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.40","description":"For Gen10 server iLO version 1.40 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM,&nbsp;which is found on the <strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><u><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></u></strong>（SPP）ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><u><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Creator Utility</a></u></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"ROMフラッシュパッケージ - アドバンスト消費電力上限マイクロコントローラーファームウェア for HPE Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"500"},"supported_operating_systems":[{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"6","minor":"0","name":"VMware vSphere 6.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-09-12T12:21:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>Ver. 1.0.7 (D) contains updates to the component packaging and is functionally equivalent to ver. 1.0.7. It is not necessary to upgrade with Revision (D) if a previous component revision was used to upgrade the firmware to ver. 1.0.7. This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>For HPE ProLiant DL325/DL385 Gen10 servers, ROM version 2.00 or later is required to enable the support. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>Added support for AMD EPYC 7002 Generation Processors on HPE ProLiant DL325/DL385 Gen10 servers. ROM version 2.00 or later is required to enable the support. This version of firmware does not include any changes for AMD EPYC 7001 Generation Processors. iLO5 version 1.40 or above is required to upgrade to this version.</p>\n\n<p>This is the initial version for HPE Gen10 Plus servers.</p>\n\n<p>Added support for VMware ESXi 7.x on AMD Gen10 and Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>Fixed an issue of inaccurate temperature readings when the actual temperature exceeds 100 &deg;C on Proliant Gen10 Plus servers.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"PowerPIC-Gen10","sw_key_expectedpath":"firmware:sd:powerpic"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U37_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11354652","datemodified":"2022-03-10T21:54:22","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/CP051195.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/U37_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051195.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051195.scexe"],"md5sum":"40ae7f5ca2f5eda5887ef8ef157e4d4c","name":"firmware-system-u37-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-10T21:47:39","revision":"0","sha1sum":"4aa52aa6eee5e91ccd91f53c8b9b402a04bd2d02","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020e"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"c02f997871554705a1c6e597965673df","version":"0e693fe33c584a308aa52506bc52c8e9"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br/> <br/>\nRPMパッケージをインストールします<br/>> rpm -Uvh <filename>.rpm<br/> <br/>ファイルが置かれる場所を確認します<br/>> rpm -qlp <filename>.rpm<br/> <br/>前の手順で確認したディレクトリに移動し、コマンドプロンプトで‘./hpqsetup’と入力してhpqsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux - HPE ProLiant XL230k Gen10 (U37)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-03-22T02:02:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092. These issues are not unique to HPE servers.\nCVE-2021-0093, CVE-2021-0144</p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the IPMI Watchdog Timer stops after a cold boot with IPMI watch dog timer enabled in RBSU</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"}],"sw_keys":[{"name":"U37","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAaseFG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB006000GWKGR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive</p>\n\n<p><strong>Release Version and/or Date:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp;</strong>None</p>\n\n<p><strong>Previous Version of Firmware:</strong></p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"18762720","datemodified":"2021-08-30T20:09:27","file_list":["/CP048329_BUILD_2.data","/CP048329.vmexe","/CP048329.vmexe64","/CP048329.vmfile","/CP048329_VMw.zip","/CP048329.xml","/payload.json","/CP048329_VMw.zip/index.xml","/CP048329_VMw.zip/vendor-index.xml","/CP048329_VMw.zip/metadata.zip","/CP048329_VMw.zip/vib20/CP048329/HPE_bootbank_CP048329_HPG1.2-7.0.0.15843807.vib","/CP048329_VMw.zip/metadata.zip/vendor-index.xml","/CP048329_VMw.zip/metadata.zip/vmware.xml","/CP048329_VMw.zip/metadata.zip/vibs/CP048329--3175177974414532236.xml","/CP048329_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048329_HPG1.2-7.0.0.15843807.xml"],"md5sum":"126f0d55eed46bc36e3e8293f2739441","name":"CP048329.zip","release":"2021-08-30T20:04:12","revision":"0","sha1sum":"e9c4c11c595c5f3217e73d717ece0d77b22c09a9","size":"17MB","target_guids":["4d2340a5-3042-3630-3030-3047574b4752"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048329","version":"HPG1.2-7.0.0.15843807"}]}],"id":{"product":"cfe4c5a213fb4be397a8b588efd29cc1","version":"361c18f57f1544ebab567b539fbe2354"},"installation":{"command":"CP041520.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB006000GWKGR ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB006000GWKGR","target_guid":"4d2340a5-3042-3630-3030-3047574b4752","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T18:18:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWKGR","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG4"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06ACHPG4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB006000GWJRR and MB008000GWJRT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB006000GWJRRおよびMB008000GWJRT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for&nbsp;Windows (x64)&nbsp;-&nbsp;MB006000GWJRR and MB008000GWJRT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3027392","datemodified":"2021-07-26T05:59:27","file_list":["cp048470.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06ACHPG4.REL"],"md5sum":"0b43c4503a90a2765387542c02792016","name":"cp048470.exe","release":"2021-07-26T05:51:04","revision":"0","sha1sum":"cbcf28cf25bcea74d367fb0459d853da50f0be5d","size":"2MB","target_guids":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"type_of_change":"1","version":"HPG4"}],"id":{"product":"e94dfd89626f4fc992d59a1c00e08f54","version":"66b693e4cf724bd6bb2271d2e8785032"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB006000GWJRRおよびMB008000GWJRTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000GWJRT","target_guid":"4d2340a5-3042-3830-3030-3047574a5254","type":"sata"},{"id":"MB006000GWJRR","target_guid":"4d2340a5-3042-3630-3030-3047574a5252","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-11T14:06:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000GWJRR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB008000GWJRT","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG0300JEHLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3330-304a45484c56","Version":"HPD5"},{"DeviceName":"EG0600JEHMA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3630-304a45484d41","Version":"HPD5"},{"DeviceName":"EG0900JEHMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3047-3930-304a45484d42","Version":"HPD5"},{"DeviceName":"EG1200JEHMC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HCFLRCD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3147-3230-304a45484d43","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG0300JEHLV, EG0600JEHMA, EG0900JEHMB, and EG1200JEHMC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB&nbsp;and&nbsp; EG1200JEHMC Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD3</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.&nbsp;</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None.</p>\n"}],"files":[{"bytes":"5525650","datemodified":"2021-07-23T08:29:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/CP048076.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/HCFLRCD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-31f91b8622-HPD5-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048076.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048076.scexe"],"md5sum":"73c5aaba3505f2df273689ffd19a46fd","name":"firmware-hdd-31f91b8622-HPD5-9.1.x86_64.rpm","release":"2021-07-23T08:16:17","revision":"0","sha1sum":"3307c2296f58b07dbb4aeb3bdf0fdc70ef383f0b","size":"5MB","target_guids":["002340a5-4500-3047-3330-304a45484c56","002340a5-4500-3047-3630-304a45484d41","002340a5-4500-3047-3930-304a45484d42","002340a5-4500-3147-3230-304a45484d43"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"99e0afc9d35746928c6cb34efe0c36a4","version":"bda08628ff654746934d77e40b60fe5c"},"installation":{"command":"CP040314.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG0300JEHLV, EG0600JEHMA, EG0900JEHMB and EG1200JEHMC Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG0300JEHLV、EG0600JEHMA、EG0900JEHMB、およびEG1200JEHMCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"EG1200JEHMC","target_guid":"002340a5-4500-3147-3230-304a45484d43","type":"sas"},{"id":"EG0300JEHLV","target_guid":"002340a5-4500-3047-3330-304a45484c56","type":"sas"},{"id":"EG0600JEHMA","target_guid":"002340a5-4500-3047-3630-304a45484d41","type":"sas"},{"id":"EG0900JEHMB","target_guid":"002340a5-4500-3047-3930-304a45484d42","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T10:43:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG0900JEHMB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG1200JEHMC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0600JEHMA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG0300JEHLV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the drivers for the HPE QLogic NX2 10Gb and 20Gb Multifunction Gigabit Ethernet NICs running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE QLogic NX2 10Gbおよび20GbマルチファンクションGigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7316223","datemodified":"2021-11-18T07:04:30","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/bnx2.ko","./lib/modules/5.3.18-22-default/updates/bnx2fc.ko","./lib/modules/5.3.18-22-default/updates/bnx2i.ko","./lib/modules/5.3.18-22-default/updates/bnx2x.ko","./lib/modules/5.3.18-22-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"3dc55a9c286ada790060cbc36bf1d0c0","name":"netxtreme2-kmp-default-7.15.02_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-11-18T06:30:00","revision":"0","sha1sum":"34a9f9dc353694ecdaf50e4ba5c72af48e81caf0","size":"6MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"1","version":"7.15.02-1"},{"bytes":"7485379","datemodified":"2021-11-18T07:02:56","file_list":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.3.18-57-default","./lib/modules/5.3.18-57-default/updates","./lib/modules/5.3.18-57-default/updates/bnx2.ko","./lib/modules/5.3.18-57-default/updates/bnx2fc.ko","./lib/modules/5.3.18-57-default/updates/bnx2i.ko","./lib/modules/5.3.18-57-default/updates/bnx2x.ko","./lib/modules/5.3.18-57-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"md5sum":"4856b2cf9ecb574f075584f1b06b2b8f","name":"netxtreme2-kmp-default-7.15.02_k5.3.18_57-1.sles15sp3.x86_64.rpm","release":"2021-11-18T06:30:00","revision":"0","sha1sum":"da98165184f71d3af99fbb6ee3e23fc5adfb5453","size":"7MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"type_of_change":"1","version":"7.15.02-1"}],"id":{"product":"eafab624995d485096ba1119b617b464","version":"489faab2bc7843878d8382a161e9d261"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>Download README for any additional installation instructions.</p>\n"},{"lang":"ja","x_late":"<p>この製品が提供するバイナリRPMパッケージは、Linuxディストリビューションに同梱されているデフォルトのインボックスカーネル（標準カーネル）用に特別に構築された、コンパイル済みのカーネルモジュールドライバーです。  HPEは、これらのコンパイル済みのカーネルモジュールRPMを指定のカーネルで使用するためにテストし、承認しました。 </p>\n\n<p>これらのコンパイル済みのRPMパッケージは、別のカーネル（errataカーネルなど）上では期待通りにインストールまたは機能しない場合があります。 デフォルトのインボックスカーネルを使用していない場合は、ドライバーのソースパッケージ（例：<ドライバー>.src.rpm）をダウンロードし、ドライバーソースからターゲットシステム用の新しいドライバーをコンパイルしてください。</p>\n\n<p>ドライバーソースRPMの場所を見つけるには、カーネルモジュールドライバーRPMに対して次のコマンドを実行します。<strong><em>localhost> rpm -qpi <カーネルモジュールドライバー名>.rpm</em></strong></p>\n\n<p> </p>\n\n<p>その他のインストール手順についてのREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE QLogic NX2 10/20 GbEマルチファンクションドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16AF","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c339d","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c18d3","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c193a","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1930","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1933","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1933","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16af103c1931","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"1917","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ad103c1917","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"3382","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c3382","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AD","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16ad159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AF","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16af15908148","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-12-16T06:42:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports MDI(Medium Dependent Interface)/MDIX(Medium Dependent Interface Crossover) connection status to ethtool.</li>\n\t<li>This product now supports Timestamping the unicast Precision Time Protocol (PTP) packets.</li>\n\t<li>This product now supports&nbsp;SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","latest_fixes_x_late":"<p>This product addresses an issue where Virtual Local Area Networks(VLANs) resource accounting when linux driver creating 272 Virtual Local Area Networks(VLANs) on single Virtual Functions, then enable interface after closed.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"netxtreme2-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK003840GWHTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M51004G8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-304757485445","Version":"HPG8"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MK003840GWHTE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;&nbsp;(x64)&nbsp;- MK003840GWHTE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG8<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG6</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3108280","datemodified":"2021-07-25T16:30:42","file_list":["cp048620.xml","cpqsetup.exe","M51004G8.rel","payload.json","setup.dll"],"md5sum":"f3f082f88d17bb0d831f8ce85a4f2c2f","name":"cp048620.exe","release":"2021-07-25T16:23:04","revision":"0","sha1sum":"2003ea61b6111d133283bb4fad72aedd91b5c1d5","size":"2MB","target_guids":["4d2340a5-304b-3330-3834-304757485445"],"type_of_change":"1","version":"HPG8"}],"id":{"product":"97296584dde64484806a51651325b7a3","version":"6823d27c2a74446c8c6f2f796766844c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK003840GWHTE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MK003840GWHTEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T12:44:07","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improvements to Product Quality and Reliability.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK003840GWHTE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB8000JFECQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRPSD7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3842-3030-304a46454351","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB8000JFECQ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"17803385","datemodified":"2021-08-27T04:55:37","file_list":["/CP048382_BUILD_2.data","/CP048382.vmexe","/CP048382.vmexe64","/CP048382.vmfile","/CP048382_VMw.zip","/CP048382.xml","/payload.json","/CP048382_VMw.zip/index.xml","/CP048382_VMw.zip/vendor-index.xml","/CP048382_VMw.zip/metadata.zip","/CP048382_VMw.zip/vib20/CP048382/HPE_bootbank_CP048382_HPD7.2-7.0.0.15843807.vib","/CP048382_VMw.zip/metadata.zip/vendor-index.xml","/CP048382_VMw.zip/metadata.zip/vmware.xml","/CP048382_VMw.zip/metadata.zip/vibs/CP048382--1568442986019898908.xml","/CP048382_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048382_HPD7.2-7.0.0.15843807.xml"],"md5sum":"e5955c566ea05a52c19e0d144434e9d6","name":"CP048382.zip","release":"2021-08-27T04:50:20","revision":"0","sha1sum":"c1a107bae5126ecaab965e613077de91a454bb6a","size":"16MB","target_guids":["002340a5-4d00-3842-3030-304a46454351"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP048382","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"b02d63095f7c44f5ba3d7deb6bb4021a","version":"38a149a277564d6591ace3cb1d3e3dc6"},"installation":{"command":"CP040532.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB8000JFECQ Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB8000JFECQドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB8000JFECQ","target_guid":"002340a5-4d00-3842-3030-304a46454351","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-08T09:22:57","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB8000JFECQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"2388019","datemodified":"2021-11-02T18:32:51","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/cac0981130d0e95ce4d041fa8d6dec038cc42b","./usr/lib/.build-id/4b","./usr/lib/.build-id/4b/ea9c804506d3028db9da7566416643c070a6c9","./usr/lib/.build-id/5d","./usr/lib/.build-id/5d/7ef4191f73c7866a85d9ecbd6bca64fad8e655","./usr/lib/.build-id/70","./usr/lib/.build-id/70/a3da26f8a11b611358c3e487aa4cd0a57687ec","./usr/lib/.build-id/74","./usr/lib/.build-id/74/d05ea9cfff50d307472c1553dc53b53f47c652","./usr/lib/.build-id/7e","./usr/lib/.build-id/7e/af8e49155606615e9b0e30155ab2e9c9bba0e6","./usr/lib/.build-id/84","./usr/lib/.build-id/84/d7a3c29fab3eef2372fe55554394e94946d90a","./usr/lib/.build-id/9c","./usr/lib/.build-id/9c/d8411cdd564c486707cc723e071ee93d67ae17","./usr/lib/.build-id/ac","./usr/lib/.build-id/ac/32c94505f374fc52c0a3783119911e3d54da24","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/1fc888d6b74c4bbb722407066b1539ce73efaf","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/93bf7d2a59eec91640d8271b8c33cb849e37a6","./usr/lib/.build-id/f4","./usr/lib/.build-id/f4/2958321e5b55335e260d44ed22925a34518748","./usr/lib/.build-id/f4/d60ccd28cbe394e5d84648618685ee22fe6ca9","./usr/lib/.build-id/ff","./usr/lib/.build-id/ff/630c17306359e9b58d9dab7d2b9a4bed822f24","./usr/lib/python3.6/site-packages/dcbnetlink.py","./usr/lib/python3.6/site-packages/genetlink.py","./usr/lib/python3.6/site-packages/netlink.py","./usr/lib/python3.6/site-packages/ofed_le_utils-1.0.3-py3.6.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1","./usr/lib64/mlnx_ofed/valgrind/libibverbs.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/libmlx4-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx4.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5-rdmav2.so","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1","./usr/lib64/mlnx_ofed/valgrind/libmlx5.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1","./usr/lib64/mlnx_ofed/valgrind/librdmacm.so.1.0.0","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1","./usr/lib64/mlnx_ofed/valgrind/rsocket/librspreload.so.1.0.0","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/ib2ib","./usr/share/doc/ib2ib/README","./usr/share/doc/libibumad","./usr/share/doc/libibumad/AUTHORS","./usr/share/doc/libibumad/COPYING","./usr/share/doc/libibumad/ChangeLog","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/AUTHORS","./usr/share/doc/libibverbs/COPYING","./usr/share/doc/libibverbs/ChangeLog","./usr/share/doc/libibverbs/README","./usr/share/doc/libmlx4","./usr/share/doc/libmlx4/AUTHORS","./usr/share/doc/libmlx4/COPYING","./usr/share/doc/libmlx4/README","./usr/share/doc/libmlx5","./usr/share/doc/libmlx5/AUTHORS","./usr/share/doc/libmlx5/COPYING","./usr/share/doc/libmlx5/README","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/AUTHORS","./usr/share/doc/librdmacm/COPYING","./usr/share/doc/librdmacm/README","./usr/share/doc/libvma-9.0.2/README.txt","./usr/share/doc/libvma-9.0.2/VMA_VERSION","./usr/share/doc/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/dcbnetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/genetlink.cpython-36.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.opt-1.pyc","./usr/lib/python3.6/site-packages/__pycache__/netlink.cpython-36.pyc"],"md5sum":"3f3ae9be29f2e48bb2b9bf07a6ef31dc","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel8u4.x86_64.rpm","release":"2021-11-02T17:29:16","revision":"0","sha1sum":"ca035f7a5d9b565e2973ed65618a323c896b30bd","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"1945265","datemodified":"2021-11-02T18:35:40","file_list":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-i40iw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_en.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fpga_tools.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.18.0-305.el8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"md5sum":"101af5d785bc9e401da3373799abeb82","name":"kmod-mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.rhel8u4.x86_64.rpm","release":"2021-11-02T17:29:16","revision":"0","sha1sum":"bf100e81cb5f6c6b850133b0d46bf7e492951456","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"a4b6c7477b3049c1b10a976c756702d9","version":"0f6d1024fff9477e988e89a29be73d6d"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"name":"Linux","value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"name":"Linux","value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"name":"Linux","value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"name":"Linux","value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPM to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot;&nbsp;RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.&nbsp;<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using kernel version 4.18.0-304.el8.x86_64 or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;kmod-mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u4.x86_64.rpm&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.rhel8u4.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for Red Hat Enterprise Linux 8 update 4 (x86_64)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"kmod-mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM4_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18f636f994","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM4 storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM4ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14025512","datemodified":"2022-01-17T16:34:53","file_list":["/CP050755_BUILD_7.data","/CP050755.vmexe","/CP050755.vmexe64","/CP050755.vmfile","/CP050755_VMw.zip","/CP050755.xml","/payload.json","/CP050755_VMw.zip/index.xml","/CP050755_VMw.zip/vendor-index.xml","/CP050755_VMw.zip/metadata.zip","/CP050755_VMw.zip/vib20/CP050755/HPE_bootbank_CP050755_1.24.7-7.0.0.15843807.vib","/CP050755_VMw.zip/metadata.zip/vendor-index.xml","/CP050755_VMw.zip/metadata.zip/vmware.xml","/CP050755_VMw.zip/metadata.zip/vibs/CP050755-3727382301640232158.xml","/CP050755_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050755_1.24.7-7.0.0.15843807.xml"],"md5sum":"c083cab0ddcc2cfd525546766049b431","name":"CP050755.zip","release":"2022-01-17T16:23:07","revision":"0","sha1sum":"ee5524ce9d39c8af636f8f2da0caf78626050656","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18f636f994"],"type_of_change":"1","version":"1.24","vib_list":[{"name":"CP050755","version":"1.24.7-7.0.0.15843807"}]}],"id":{"product":"cda15b2dd1914971b9e0993731ba714c","version":"c0659b9d74894692873f5998361dd512"},"installation":{"command":"CP050755.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>「追加情報」に記載されている指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./Execute_Component </li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./ Execute_Component</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM4 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor VMware Esxi - Gen10Plus UBM4バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901504000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:39:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"UBM4","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"The Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array and SmartRAID Controllers and any supported devices, including providing SmartSSD Wear Gauge information for supported drives."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"4291137","datemodified":"2022-01-24T11:24:29","file_list":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"md5sum":"d38866c3d2676c3bffad30aa6efd0bc8","name":"ssaducli-5.30-6.0.x86_64.rpm","release":"2022-01-24T11:23:40","revision":"0","sha1sum":"876dcb90901de28f5098384f7357049aa1c8880d","size":"4MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"type_of_change":"1","version":"5.30.6.0"}],"id":{"product":"7a0e2103ab3d449ea173c873ce94c871","version":"bb80119727b4467885bff85d510a84e9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<ul>\n\t<li>SSADUCLI is distributed using Red Hat Package Manager (RPM) packages.</li>\n\t<li>If there is an older version of SSADUCLI installed on the system, please use &quot;rpm -e ssacli&quot; to remove it first.</li>\n\t<li>Use &quot;rpm -i &lt;file name&gt;&quot; to install the application.</li>\n\t<li>Please type &quot;man rpm&quot; for other details regarding RPM.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux (64 位元) 的 Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"en","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit"},{"lang":"ko","x_late":"Linux 64비트용 스마트 스토리지 관리자 진단 유틸리티(SSADU) CLI"},{"lang":"cn","x_late":"64位Linux版Smart Storage Administrator Diagnostic Utility (SSADU) CLI"},{"lang":"ja","x_late":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64ビット"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-05T08:06:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added initial passive SED support.</li>\n\t<li>Added new &quot;unchanged&quot; Drive Write Cache (DWC) policy to the applications.</li>\n\t<li>Added support for discovering and reporting failed drives that are not part of a RAID volume.</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Fixed an issue where the &quot;Turn off&quot; LED operation momentarily turns on all Identify LED.</li>\n\t<li>Fixed an issue where an NVME drive was failed after flashing drive firmware.</li>\n\t<li>Fixed an issue where an operation failure message was observed while deleting a volume with status &ldquo;Not Available&rdquo;.</li>\n\t<li>Fixed an issue that SSAScripting reported incorrect size for some drives greater than 1TB. This did not affect SSACLI.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>Initial Build</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2200 Gen10 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"},{"key":"U38","value":"HPE Apollo r2600 Gen10 24 SFF Premium Configure-to-order Chassis"},{"key":"","value":"HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"I40","value":"HPE Synergy 620 Gen9 Compute Module"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"Carbondale14","value":"HPE Apollo 4530 Gen9 Configure-to-order Chassis"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U14","value":"HPE Apollo r2800 Gen9 24 SFF with Expander Configure-to-order Chassis"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4520 Gen9 Chassis</p>\n"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"","value":"HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"I40","value":"HPE Synergy 680 Gen9 Compute Module"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U27","value":"HPE ProLiant XL2x260w Gen9 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"Carbondale14","value":"<p>HPE Apollo 4510 Gen9 Configure-to-order Chassis</p>\n"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"","value":"HPE ProLiant ML150 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"","value":"HPE ProLiant XL770f Gen9 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ssaducli","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_E810_XXV4_OCP_3p00_NCSIwPLDMoMCTP_80008280.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"3.00"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading Intel E810-XXVDA4 OCP3 Gigabit Ethernet NIC firmware."},{"lang":"ja","x_late":"このパッケージには、Intel E810-XXVDA4 OCP3 Gigabit Ethernet NICファームウェアをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions for the below listed supported network adapters:</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROM Version</th>\n\t\t\t<th>NVM Version</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter</td>\n\t\t\t<td>80008280</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>The combo image v1.2992.0&nbsp;includes: Intel(R) Boot Agent ICE v2.5.0&nbsp;&amp; UEFI x64 100 gigabit driver v3.0.11.</p>\n"},{"lang":"ja","x_late":"<p>このソフトウェアパッケージは、以下にリストされるサポートされるネットワークアダプターの次のファームウェアのバージョンを含みます：</p>\n\n<table border=\"1\">\n\t<thead>\n\t\t<tr>\n\t\t\t<th>NIC</th>\n\t\t\t<th>EEPROM ID</th>\n\t\t\t<th>OROMバージョン</th>\n\t\t\t<th>NVMバージョン</th>\n\t\t</tr>\n\t</thead>\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Intel E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28アダプター</td>\n\t\t\t<td>80008280</td>\n\t\t\t<td>1.2992.0</td>\n\t\t\t<td>3.00</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>コンボイメージv1.2992.0は以下を含みます：インテル(R)ブートエージェントICE v2.5.0およびUEFI x64 100ギガビットドライバーv3.0.11。</p>\n"}],"files":[{"bytes":"10517633","datemodified":"2021-08-12T13:56:38","file_list":["HPE_E810_XXV4_OCP_3p00_NCSIwPLDMoMCTP_80008280.HPb","HPE_E810_XXV4_OCP_3p00_NCSIwPLDMoMCTP_80008280.xml","payload.json"],"md5sum":"07a30b686aa67c71b4d741b461b9611f","name":"HPE_E810_XXV4_OCP_3p00_NCSIwPLDMoMCTP_80008280.fwpkg","release":"2021-09-16T00:00:00","revision":"1","sha1sum":"4b735979dab4ca9ac6046f35b95e9832ae7448a8","size":"10MB","target_guids":["a6b1a447-382a-5a4f-8086-15938086000c"],"type_of_change":"1","version":"3.00"}],"id":{"product":"6adb26c5fc564f219877ab6a448e709b","version":"7c4a5238c34b4cbe904dad5fa7671f61"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Flash the PLDM firmware using any below methods</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>Flash using iLOrest tool&nbsp;</li>\n\t<li>Flash using&nbsp;Smart Update Manager (SUM).</li>\n\t<li>Flash from iLO GUI</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\"><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>.</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">Reboot your system for the update to take effect immediately</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.&nbsp;Flash from iLO GUI</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Browse iLO IP using any browser and login using the credential&nbsp;</li>\n\t<li>Make sure the PLDM supported adapter is present in the server</li>\n\t<li>Go to iLO GUI -&gt; Click on &quot;Firmware and OS software&quot; from left side&nbsp;&nbsp;-&gt; Click on &quot;Update Firmware&quot; -&gt; Click on &quot;Choose File&quot; and browse to the supported PLDM file -&gt; Then click on &quot;Flash&quot; button.&nbsp;</li>\n\t<li>Update status will be show in the Top and a log entry can be seen in Integrated Managenment Log (IML)&nbsp;</li>\n\t<li>Reboot the server for the firmware update to take effect.</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">以下のいずれかの方法を使用してPLDMファームウェアをフラッシュします</p>\n\n<ol style=\"list-style-type:decimal\">\n\t<li>iLOrestツールを使用したフラッシュ </li>\n\t<li>Smart Update Manager（SUM）を使用したフラッシュ</li>\n\t<li>iLO GUIからのフラッシュ</li>\n</ol>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">1. このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">2. このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\"><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Creator Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</p>\n\t</li>\n\t<li>\n\t<p style=\"margin-left:0px; margin-right:0px\">アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</p>\n\t</li>\n</ul>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p style=\"margin-left:40px; margin-right:0px; text-align:left\">アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">3.  iLO GUIからのフラッシュ</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>任意のブラウザーを使用してiLO IPを参照し、資格情報を使用してログインします </li>\n\t<li>PLDMでサポートされているアダプターがサーバーに存在していることを確認します</li>\n\t<li>iLO GUIに移動します -> 左側から[Firmware and OS software]をクリックします -> [Update Firmware]をクリックします -> [Choose File]をクリックして、サポートされているPLDMファイルを参照します -> [Flash]ボタンをクリックします。 </li>\n\t<li>アップデートステータスが上部に表示され、インテグレーテッドマネジメントログ（IML）にログエントリが記録されます。 </li>\n\t<li>ファームウェアアップデートを有効にするためにサーバーを再起動します。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<ul>\n\t<li>ファームウェアをアップデートする場合は、リビジョン履歴を参照し、必要なバージョンまで1つずつアップデートしていきます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter"},{"lang":"ja","x_late":"Intelファームウェアパッケージfor E810-XXVDA4 Ethernet 10/25Gb 4ポートSFP28 OCP3アダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_devices":[{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-11-01T08:47:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This product addresses an issue where Firmware version isn&#39;t correct in AHS log when upgading Firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"INTEL_E810_XXV4OCP_PKG","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB2000JFEPA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304a46455041","Version":"HPD5"},{"DeviceName":"MB4000JFEPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMKRAND5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a46455042","Version":"HPD5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following SAS drive models: MB2000JFEPA and MB4000JFEPB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB2000JFEPAおよびMB4000JFEPB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong>&nbsp;&nbsp;&nbsp;&nbsp;<br />\n&nbsp;&nbsp;&nbsp;&nbsp; None&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>None.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5490903","datemodified":"2021-07-23T07:16:42","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/CP048160.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/SMKRAND5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-326de7c0f2-HPD5-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048160.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048160.scexe"],"md5sum":"102f6a6022f526c1adb631256bb78935","name":"firmware-hdd-326de7c0f2-HPD5-8.1.x86_64.rpm","release":"2021-07-23T07:03:26","revision":"0","sha1sum":"e6c5e97d87a47228bda45c6906d20cbd7d51b28f","size":"5MB","target_guids":["002340a5-4d00-3242-3030-304a46455041","002340a5-4d00-3442-3030-304a46455042"],"type_of_change":"1","version":"HPD5"}],"id":{"product":"cd64600f655f440ba11117463945fc63","version":"7c8eb566a11a45aab6f4292a14ba4876"},"installation":{"command":"CP040291.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB2000JFEPA and MB4000JFEPB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB2000JFEPAおよびMB4000JFEPBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB2000JFEPA","target_guid":"002340a5-4d00-3242-3030-304a46455041","type":"sas"},{"id":"MB4000JFEPB","target_guid":"002340a5-4d00-3442-3030-304a46455042","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:07:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JFEPB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB2000JFEPA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and binaries for upgrading for HPE VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 devices on Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージは、Linux x86_64プラットフォーム上でHPE VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5デバイスをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"9451962","datemodified":"2022-02-09T21:10:07","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/CP050381.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050381.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050381.scexe"],"md5sum":"090c71692f78849bc64168bd1ac0bd9c","name":"firmware-hca-mellanox-vpi-connectx4-1.0.12-1.1.x86_64.rpm","release":"2022-02-09T12:23:57","revision":"0","sha1sum":"d656b4d188966143329d4f2eda6c1fa9c100410d","size":"9MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.12"}],"id":{"product":"da6c398c130f48f9a5a32bd3c9213a90","version":"9f995806f79a4208899618fcba0b5197"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(Linux x86_64)for HPE Mellanox VPI(EthernetおよびInfinibandモード)ConnectX4デバイス - Linux x86_64プラットフォーム"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T06:46:55","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1200:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>&nbsp;&nbsp;Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and&nbsp;&nbsp;the DQPN.</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). <strong>Note:</strong> If the port does not go up, switch to Force mode.</li>\n</ul>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li>\n\t<li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li>\n\t<li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New Features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixes an issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed n issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U33_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11262159","datemodified":"2022-03-08T13:24:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/CP051286.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/U33_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051286.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051286.scexe"],"md5sum":"4c2b6ffc21ac94fbb894f14c3a7d50da","name":"firmware-system-u33-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-08T13:18:04","revision":"0","sha1sum":"f06bb99736af02225e77e06ee7db9be8a2651677","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020b"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"dea19449209743ffa1d2262e07eafb25","version":"6ce32c19b1ca43caac5d3f8b2745ec58"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant ML110 Gen10 (U33)サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"9","minor":"0","name":"Red Hat Enterprise Linux 9 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:36:29","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"}],"sw_keys":[{"name":"U33","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"The lsi-mr3 controller driver component for VMware vSphere 6.7, for use with HPE Smart Update Manager."},{"lang":"ja","x_late":"HPE Smart Update Managerで使用するVMware vSphere 6.7用lsi-mr3コントローラードライバーコンポーネント"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"110997","datemodified":"2021-09-09T08:02:53","file_list":["/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip","/cp049485.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922.vib","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vendor-index.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vmware.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/vibs/lsi-mr3-8423814040991640656.xml","/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922-offline_bundle-17653784.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.716.03.00-1OEM.670.0.0.8169922.xml"],"md5sum":"ebdb26df6900fe863f23addcca44ec45","name":"cp049485.zip","release":"2021-09-09T08:02:02","revision":"0","sha1sum":"300984e8f5369c16550301e938755a89d2b7a078","size":"108KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"type_of_change":"1","version":"2021.04.01","vib_list":[{"name":"lsi-mr3","version":"7.716.03.00-1OEM.670.0.0.8169922"}]}],"id":{"product":"862f9bdea0634dd0aa757317bd803752","version":"60464806c9ac43c5ac0e93a82978dbe3"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant</strong></p>\n\n<p><strong>Remote Online: </strong></p>\n\n<ul>\n\t<li>&nbsp;Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a></li>\n\t<li>&nbsp;Place the desired driver to be updated in the directory, /SPP20xxxxx/hpe/swpackages on the USB key.</li>\n\t<li>&nbsp;Mount the USB key on a remote server running Windows or Linux</li>\n\t<li>&nbsp;CD /hpe/swpackages and ./hpesum</li>\n\t<li>&nbsp;Select the next button</li>\n\t<li>&nbsp;Click Add Single Target</li>\n\t<li>&nbsp;Type the IP or DNS address of the ESXi host to be updated</li>\n\t<li>&nbsp;Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>&nbsp;Follow Smart Update Manager Steps and complete the update.</li>\n</ul>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ul>\n\t<li>&nbsp;Unzip this HPE component to extract the driver offline bundle</li>\n\t<li>&nbsp;Use VMware VUM or esxcli commands to install the offline bundle.</li>\n\t<li>&nbsp;Refer to VMware documentation for information on VUM and the esxcli commands.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、HPE Service Pack for ProLiantから以下の手順に従ってください</strong></p>\n\n<p><strong>リモートオンライン: </strong></p>\n\n<ul>\n\t<li> <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658\"><u>HPE USB Key Utility</u></a>を使用して、SPPをUSBキーにコピーします</li>\n\t<li> アップデートするドライバーをUSBキーの/SPP20xxxxx/hpe/swpackagesディレクトリにコピーします。</li>\n\t<li> WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li> CD /hpe/swpackages および ./hpesum</li>\n\t<li> 次へボタンを選択します。</li>\n\t<li> シングルターゲットの追加をクリックします。</li>\n\t<li> アップデートされるESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li> ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li> Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ul>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ul>\n\t<li> ドライバーオフラインバンドルを抽出するために、このHPEコンポーネントを解凍します</li>\n\t<li> オフラインバンドルをインストールするために、VMware VUMまたはesxcliコマンドを使用します。</li>\n\t<li> VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller (64-bit) Driver for vSphere 6.7 (Driver Component)"},{"lang":"ja","x_late":"HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラー（64-bit）ドライバーfor vSphere 6.7 (ドライバーコンポーネント)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T10:37:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"lsi-mr3:7.716.03.00-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"en","x_late":"This package contains utilities and libraries to enable HPE Storage fibre channel array connectivity on SUSE Linux Enterprise Server 12 for Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージには、SUSE Linux Enterprise Server 12上でEmulexホストバスアダプターおよびメザニンホストバスアダプターに対してHPE Storageファイバーチャネルアレイ接続を有効にするためのユーティリティとライブラリが含まれています。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1790136","datemodified":"2021-11-15T07:38:59","file_list":["./opt/emulex/sles12sp5/i386/lib/libdfc.so","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12","./opt/emulex/sles12sp5/i386/lib/libdfc.so.12.8.526","./opt/emulex/sles12sp5/i386/lib/libemsdm.so","./opt/emulex/sles12sp5/i386/lib/libemulexhbaapi.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12","./opt/emulex/sles12sp5/x86_64/lib64/libdfc.so.12.8.526","./opt/emulex/sles12sp5/x86_64/lib64/libemsdm.so","./opt/emulex/sles12sp5/x86_64/lib64/libemulexhbaapi.so","./usr/lib/libdfc.so","./usr/lib/libdfc.so.12","./usr/lib/libdfc.so.12.8.526","./usr/lib/libemsdm.so","./usr/lib/libemulexhbaapi.so","./usr/lib64/libdfc.so","./usr/lib64/libdfc.so.12","./usr/lib64/libdfc.so.12.8.526","./usr/lib64/libemsdm.so","./usr/lib64/libemulexhbaapi.so","./usr/share/smartupdate/HPE-CNA-FC-Emulex-Enablement-Kit/component.xml"],"md5sum":"7868cb9369aa10d54a90e5963a5d1482","name":"HPE-CNA-FC-Emulex-Enablement-Kit-12.8.526.0-1.sles12sp5.x86_64.rpm","release":"2021-11-15T07:27:11","revision":"0","sha1sum":"92229f9b6ae0267504281d7692eabd1cc5fb0e7e","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1758d109"],"type_of_change":"1","version":"12.8.526.0"}],"id":{"product":"489fcd07381047728f0d8307f128b6be","version":"2010c25cd8c94d8385ea9728460d590f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The target environment must have the libHBAAPI Package installed prior to the installation of the enablement kit. (If not already present, the libHBAAPI Package can be obtained from the operating system installation media.)</p>\n\n<p>&nbsp;</p>\n\n<p>This version of the enablement kit does not provide the additional functionality of rebuilding the ram disk or setting driver parameters as the previous versions had done.&nbsp; Please refer to the &ldquo;Additional setup&rdquo; section of the Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guide for instructions on how to perform these functions.&nbsp; The reference guide is available at the following link:</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>Rewrite of same Enablement kit version on&nbsp;SuSE Linux Enterprise Server 12 service pack 5 has to be performed using &ndash;force or --replacepkgs with --nodeps option</p>\n\n<p>Example:&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --force --nodeps</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;rpm &ndash;Uvh HPE-CNA-FC-Emulex-Enablement-Kit-&lt;version&gt;.&lt;OS&gt;.&lt;architecture&gt;.rpm --replacepkgs --nodeps</p>\n\n<p>&nbsp;For more information please refer the Knowledge Base at: <a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"},{"lang":"ja","x_late":"<p>イネーブルメントキットのインストール前にターゲット環境にlibHBAAPIパッケージをインストールしておく必要があります。（存在していない場合、libHBAAPIパッケージはオペレーティングシステムのインストールメディアから取得することができます。）</p>\n\n<p> </p>\n\n<p>このバージョンのイネーブルメントキットは、以前のバージョンが行ったようなRAMディスクの再構築またはドライバーパラメーターの設定といった追加の機能を提供しません。  これらの機能を実行する方法については、Native Linux Device-Mapper Multipath for HPE StorageWorks Arrays reference guideの「Additional setup」セクションを参照してください。  リファレンスガイドは、次のリンクから入手可能です：</p>\n\n<p><a href=\"http://www.hpe.com/storage/spock/\">http://www.hpe.com/storage/spock/</a></p>\n\n<p>SuSE Linux Enterprise Server 12サービスパック5での同じイネーブルメントキットバージョンの書き換えは、–forceまたは--replacepkgsと--nodepsオプションを使用して実行する必要があります。</p>\n\n<p>例：rpm –Uvh HPE-CNA-FC-Emulex-Enablement-Kit-<version>.<OS>.<architecture>.rpm --force --nodeps</p>\n\n<p>                rpm –Uvh HPE-CNA-FC-Emulex-Enablement-Kit-<version>.<OS>.<architecture>.rpm --replacepkgs --nodeps</p>\n\n<p> 詳しくは、次のナレッジベースを参照してください。<a href=\"https://www.suse.com/support/kb/doc/?id=000019640\">https://www.suse.com/support/kb/doc/?id=000019640</a></p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex Fibre Channel Enablement Kit for Host Bus Adapters and Mezzanine Host Bus Adapters for SUSE Linux Enterprise Server 12"},{"lang":"ja","x_late":"HPE Emulexファイバーチャネルイネーブルメントキットforホストバスアダプターおよびメザニンホストバスアダプター - SUSE Linux Enterprise Server 12"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to version 12.8.526.0</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"HPE-CNA-FC-Emulex-Enablement-Kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMは、HPE Storageファイバーチャネルアダプターおよびメザニンホストバスアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"532387","datemodified":"2021-12-02T04:52:15","file_list":["./etc/depmod.d/lpfc.conf","./lib/modules/3.10.0-1160.36.2.el7.x86_64","./lib/modules/3.10.0-1160.36.2.el7.x86_64/extra","./lib/modules/3.10.0-1160.36.2.el7.x86_64/extra/elx-lpfc","./lib/modules/3.10.0-1160.36.2.el7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"8a696cfbacee52ba6e88022d1e7cc185","name":"kmod-elx-lpfc-12.8.528.29_k3.10.0_1160.36.2-1.rhel7u9.x86_64.rpm","release":"2021-12-02T04:46:47","revision":"0","sha1sum":"c2eb44a1617661424a438d49988c4f4d66f655ed","size":"519KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.528.29"}],"id":{"product":"7cf8ba0f8b844dfea7c2c8e00f2f739c","version":"0d7c97481bed4121aaa8b9986fbff610"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"},{"lang":"ja","x_late":"<p>1.  システム管理者 (root) としてログインします。</p>\n\n<p>2.  RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>3.  ドライバーをインストールあるいはアップグレードするには、プロンプトで次のコマンドをタイプします。<br />\n<br />\n                    # rpm -Uvh elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64.rpm<br />\n<br />\n                    例：# rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.  インストールまたはアップグレードがエラーを出さずに完了したら、変更を有効にするためにサーバーを再起動してください。 </p>\n\n<p><strong>重要</strong>：インストールの失敗、あるいは警告やエラーメッセージを表示して停止した場合は、コンピューターを再起動しないでください。ドライバーは動作しないため、以下のコマンドをタイプしてアンインストールしてください。<br />\n<br />\n                    # rpm -e elx-lpfc-<kerneltype><version>.<OSupdate>.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 7 Update 9 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 7 Update 9 Serverファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプターおよびメザニンホストバスアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:26","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Updated to driver version 12.8.528.29</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300027","languages":[{"lang":"tw","x_late":"驅動程式 ─ 系統"},{"lang":"en","x_late":"Driver - System"},{"lang":"ko","x_late":"드라이버 - 시스템"},{"lang":"ja","x_late":"ドライバ - システム"},{"lang":"cn","x_late":"驱动程序 - 系统"}]}],"description":[{"lang":"en","x_late":"This component provides drivers for HPE NVDIMM-N devices and HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory) installed on systems running Microsoft Windows Server 2016."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"1015448","datemodified":"2021-09-07T14:00:23","file_list":["cp047945.xml","cpqsetup.exe","hpenvmbus.cat","HpeNvmBus.inf","HpeNvmBus.pdb","HpeNVMBus.sys","HpeNvmBusApi.h","HpeNVMdisk0101.cat","HpeNvmDisk0101.inf","HpeNvmDisk0101.pdb","Hpenvmdisk0101.sys","HpeNvmDsm.h","HpeNvmInstaller.dll","install.xml"],"md5sum":"a7a8abab4b3bea5f3f173ac3d0a88b66","name":"cp047945.exe","release":"2021-09-07T13:58:08","revision":"0","sha1sum":"49f0964685f010330ff9cc65b0ebb3198d83bd2c","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ece0b66b06"],"type_of_change":"1","version":"3.0.2.0"}],"id":{"product":"45e734b674094fd09fe52836988b3440","version":"77edcc23a0964916bb1b7c8a0238b156"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Steps to install this Smart Component:</p>\n\n<ul>\n\t<li>If a previous version is already installed, it is recommended to first stop all use of the Persistent Memory devices and disks, and uninstall&nbsp;it from the Control Panel, Uninstall a Program.</li>\n\t<li>Download the Smart Component to a directory on your hard drive and change to that directory.</li>\n\t<li>From that drive and directory, execute the downloaded file.</li>\n\t<li>Click the Install button to proceed with the installation.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>このSmartコンポーネントをインストールする手順：</p>\n\n<ul>\n\t<li>以前のバージョンがすでにインストールされている場合は、最初にPersistent Memoryデバイスとディスクの使用をすべて停止し、[コントロールパネル]の[プログラムのアンインストール]からアンインストールすることをお勧めします。</li>\n\t<li>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</li>\n\t<li>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</li>\n\t<li>[インストール]ボタンをクリックして、インストールを開始してください。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Non-Volatile Memory Drivers for Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"4096"},"supported_devices":[{"id":"ACPI\\VEN_ACPI&DEV_0012","target_guid":"","type":"pnp"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-17T00:45:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These Non-Volatile Memory&nbsp;drivers enable support for Persistent Memory technology on select HPE Servers running Microsoft Windows Server 2012 R2 and 2016.</p>\n\n<ul>\n\t<li>Added support for Microsoft virtual NVDIMMs (aka vNVDIMMs) presented by Hyper-V Server 2019, on WS2012R2 and WS2016 guests.</li>\n\t<li>Added support for HPE Persistent Memory devices (featuring Intel Optane DC Persistent Memory), on WS2012R2 and WS2016.</li>\n\t<li>Added support for HPE 16GB NVDIMM devices, on WS2012R2.</li>\n\t<li>Changed block sector size from 512B to 4096B. Old data won&#39;t be accessible and must be backed up first if it needs to be preserved.</li>\n</ul>\n\n<p>For more information about Persistent Memory technology offered on HPE Servers, please consult the following links:</p>\n\n<ul>\n\t<li><a href=\"https://www.hpe.com/us/en/servers/persistent-memory.html\">https://www.hpe.com/us/en/servers/persistent-memory.html</a></li>\n\t<li><a href=\"https://persistentmemory.hpe.com/windows/nvdimm\">https://persistentmemory.hpe.com/windows/nvdimm</a></li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Removed support for Windows Server 2012 R2</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"HpeNvmInstaller.dll","sw_key_expectedpath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"LO0400KEFJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3430-304b45464a51","Version":"HPK4"},{"DeviceName":"LO0800KEFJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-304f-3830-304b45464a52","Version":"HPK4"},{"DeviceName":"LO1600KEFJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-314f-3630-304b45464a54","Version":"HPK4"},{"DeviceName":"LO2000KEFJU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-324f-3030-304b45464a55","Version":"HPK4"},{"DeviceName":"LT0800KEXVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3054-3830-304b45585641","Version":"HPK4"},{"DeviceName":"LT1600KEXVB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3154-3630-304b45585642","Version":"HPK4"},{"DeviceName":"LT2000KEXVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IFDHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4c00-3254-3030-304b45585643","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB&nbsp;and LT2000KEXVC Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4760195","datemodified":"2021-07-25T12:46:14","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/4IFDHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/CP045364.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d64642c780-HPK4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP045364.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP045364.scexe"],"md5sum":"9ce597464c7ca0871d8e952112732d96","name":"firmware-hdd-d64642c780-HPK4-6.1.x86_64.rpm","release":"2021-07-25T12:33:18","revision":"0","sha1sum":"300eed7e4c777cdc33cadbbc92ae2cbdeefb99b1","size":"4MB","target_guids":["002340a5-4c00-304f-3430-304b45464a51","002340a5-4c00-304f-3830-304b45464a52","002340a5-4c00-314f-3630-304b45464a54","002340a5-4c00-324f-3030-304b45464a55","002340a5-4c00-3054-3830-304b45585641","002340a5-4c00-3154-3630-304b45585642","002340a5-4c00-3254-3030-304b45585643"],"type_of_change":"1","version":"HPK4"}],"id":{"product":"ae103f89c84644ff9172375f2aa2c907","version":"a3c4d16c14314b6ba853a9f916ec46ec"},"installation":{"command":"CP040114.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - LO0400KEFJQ, LO0800KEFJR, LO1600KEFJT, LO2000KEFJU, LT0800KEXVA, LT1600KEXVB and LT2000KEXVC Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - LO0400KEFJQ、LO0800KEFJR、LO1600KEFJT、LO2000KEFJU、LT0800KEXVA、LT1600KEXVB、およびLT2000KEXVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"LT0800KEXVA","target_guid":"002340a5-4c00-3054-3830-304b45585641","type":"nvme"},{"id":"LT1600KEXVB","target_guid":"002340a5-4c00-3154-3630-304b45585642","type":"nvme"},{"id":"LT2000KEXVC","target_guid":"002340a5-4c00-3254-3030-304b45585643","type":"nvme"},{"id":"LO2000KEFJU","target_guid":"002340a5-4c00-324f-3030-304b45464a55","type":"nvme"},{"id":"LO0400KEFJQ","target_guid":"002340a5-4c00-304f-3430-304b45464a51","type":"nvme"},{"id":"LO0800KEFJR","target_guid":"002340a5-4c00-304f-3830-304b45464a52","type":"nvme"},{"id":"LO1600KEFJT","target_guid":"002340a5-4c00-314f-3630-304b45464a54","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-09-25T11:12:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.2</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"LO0400KEFJQ","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO1600KEFJT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT2000KEXVC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO0800KEFJR","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT0800KEXVA","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LT1600KEXVB","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"LO2000KEFJU","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825110-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_2006-825111-B21_Ax_Bx-UEFI-14.21.17-FlexBoot-3.6.102.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.2006"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-872726-B21_Ax_Bx-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.32.1010"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_32_1010-879482-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX4 and ConnectX5 adapter firmware on VMware ESXi 6.5"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.5上でHPE Mellanox VPI（EthernetおよびInfinibandモードで動作）ConnectX4およびConnectX5アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (825110-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2180110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (825111-B21)</td>\n\t\t\t<td>12.28.2006</td>\n\t\t\t<td>HP_2190110032</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter (872726-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000009</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (879482-B21)</td>\n\t\t\t<td>16.32.1010</td>\n\t\t\t<td>HPE0000000022</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"29867983","datemodified":"2022-02-05T14:15:50","file_list":["/CP050377.vmexe","/CP050377.vmfile","/CP050377.xml","/CP050377_VMw.zip","/payload.json","/README.txt","/CP050377_VMw.zip/index.xml","/CP050377_VMw.zip/vendor-index.xml","/CP050377_VMw.zip/metadata.zip","/CP050377_VMw.zip/vib20/CP050377/HPE_bootbank_CP050377_1.0.3-6.5.0.4240417.vib","/CP050377_VMw.zip/metadata.zip/vendor-index.xml","/CP050377_VMw.zip/metadata.zip/vmware.xml","/CP050377_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050377_1.0.3-6.5.0.4240417.xml","/CP050377_VMw.zip/metadata.zip/vibs/CP050377--3250038964663778246.xml"],"md5sum":"877307cf9f9e39135c4c5c3a555f2d9c","name":"CP050377.zip","release":"2022-02-05T17:09:53","revision":"0","sha1sum":"f7cc495689eb821ec808d37763b59ccddc368231","size":"28MB","target_guids":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"type_of_change":"1","version":"1.0.10","vib_list":[{"name":"CP050377","version":"1.0.3-6.5.0.4240417"}]}],"id":{"product":"c1b78da8d92c4109b1ad0059c99cc84f","version":"9dc9e3ca2c20419faf48be99fdd30026"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Download the appropriate SPP</li>\n\t<li>&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>&nbsp; &nbsp; Run SUM</li>\n\t<li>&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;</li>\n\t<li>&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;</li>\n\t<li>&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update</li>\n\t<li>&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></li>\n</ul>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;</li>\n\t<li>&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;</li>\n\t<li>&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;</li>\n\t<li>&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;</p>\n\n<ul>\n\t<li>&nbsp; &nbsp; Enable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;</li>\n\t<li>&nbsp; &nbsp; Place the Smart Component in a temporary directory</li>\n\t<li>&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst</li>\n\t<li>&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst</li>\n\t<li>&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe</li>\n\t<li>&nbsp; &nbsp; Follow the directions given by the Smart Component.</li>\n\t<li>&nbsp; &nbsp; Logout.</li>\n\t<li>&nbsp; &nbsp; Disable SSH on the ESXi host.</li>\n\t<li>&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</li>\n</ul>\n\n<p><strong>Note:&nbsp;</strong>In order to upgrade CX5 network adapter firmware from 16.21.1xxx or 16.22.1xxx (or earlier) to 16.26.1xxx (or later), use 16.23.1xxx or 16.24.1xxx or 16.25.1xxx as intermediate firmware version.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.5) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 6.5"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ(ESXi 6.5) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX4およびConnectX5デバイス - VMware ESXi 6.5"}],"prerequisites":{"required_diskspace":{"size_kb":"13000"},"supported_devices":[{"dev":"1013","subdev":"00C7","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c7","type":"pci","ven":"15b3"},{"dev":"1013","subdev":"00C8","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1013159000c8","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0256","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900256","type":"pci","ven":"15b3"},{"dev":"1017","subdev":"0282","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101715900282","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T06:46:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 12.28.2006:</strong></p>\n\n<p>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)<br />\n825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New Feature and Changes in Version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 16.31.1200:</strong></p>\n\n<p>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)<br />\n872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)<br />\n&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>&nbsp;&nbsp;Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>&nbsp;&nbsp;Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and&nbsp;&nbsp;the DQPN.</li>\n\t<li>Added a new NVconfig per Port for a specific Finisar module. This new NVconfig sets the port to work in AN mode and sets the module to No DME. This change does not affect the speed logic, only the FEC logic (FEC override). <strong>Note:</strong> If the port does not go up, switch to Force mode.</li>\n</ul>\n\n<p>&nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in firmware version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>An issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>An issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>An assert that was caused when trying to open 1024 functions on the device and the maximum number of functions was 1023.</li>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to hang.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 16.31.1200:</strong></p>\n\n<ul>\n\t<li style=\"margin-left: 40px;\">Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the TMP421 sensor temperature reporting.</li>\n\t<li style=\"margin-left: 40px;\">Fixed the rate select mechanism in QSFP modules.</li>\n\t<li style=\"margin-left: 40px;\">Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li style=\"margin-left: 40px;\">Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 12.28.2006:</strong></p>\n\n<ul>\n\t<li>825110-B21 (HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter)</li>\n\t<li>825111-B21 (HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter)<br />\n\t&nbsp;</li>\n</ul>\n\n<p><strong>Firmware for the following devices has been&nbsp;updated to 16.32.1010:</strong></p>\n\n<ul>\n\t<li>879482-B21 (HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter)</li>\n\t<li>872726-B21 (HPE InfiniBand EDR/Ethernet 100Gb&nbsp;2-port 841QSFP28 Adapter)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New Features and changes included in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Increased the maximum XRQ number to 512.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>New features and changes included in version 16.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. In case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit perhost per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Disabled VST on dual port adapter cards when one port is configured as ETH and the other as IB as VST is not available when the port is set as ETH.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n</ul>\n\n<p>&nbsp;</p>\n","curr_fixes_x_late":"<p><strong>Fixes in version 12.28.2006:</strong></p>\n\n<ul>\n\t<li>Fixes an issue that caused the DCR to be destroyed before the retry option managed to work when the retry timeout is too big. In this case the DCR&#39; time-to-live was increased, and the maximum retry timeout was decreased.</li>\n\t<li>Increased PHY power consumption limit to 1.5w.</li>\n\t<li>Fixed n issue that caused PortCounters.PortRcvErr / PPCNT.infiniband_counters.PortRcvErr not to report port icrc errors.</li>\n</ul>\n\n<p><strong>The following issues have been fixed in version 16.32.1010</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n\t<li>The system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>A fatal assert 0x81C5 occurred when calling get_vport_mad from the MAD APIs. The firmware was trying to compute the number of vPorts using a global function number. To avoid this issue, the API was updated to remove any assumption on the function number. Note: This issue is affects only IB devices.</li>\n\t<li>During events, stress caused the firmware to reset the Arm host of the vPort without sending an event. Thus preventing the software from rearming the vPort as it did not receive any event, and the firmware did not send the event because the vPort had no Arm set.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n\t<li>PCIe lane margining capability issues.</li>\n\t<li>An issue related to the sl2vl mad that caused a few msec hiccup in the transmission on an InfiniBand network when the SM sent the sl2vl mad to a node in the cluster.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX4_CX5","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB1000GVYZE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3142-3030-304756595a45","Version":"HPG4"},{"DeviceName":"MB2000GVYZF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3242-3030-304756595a46","Version":"HPG4"},{"DeviceName":"MB3000GVYZH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3342-3030-304756595a48","Version":"HPG4"},{"DeviceName":"MB4000GVYZK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMBPNTG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304756595a4b","Version":"HPG4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH&nbsp;and MB4000GVYZK Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG4<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;&nbsp;</strong>None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"17008974","datemodified":"2021-08-26T17:53:15","file_list":["/CP048343_BUILD_2.data","/CP048343.vmexe","/CP048343.vmexe64","/CP048343.vmfile","/CP048343_VMw.zip","/CP048343.xml","/payload.json","/CP048343_VMw.zip/index.xml","/CP048343_VMw.zip/vendor-index.xml","/CP048343_VMw.zip/metadata.zip","/CP048343_VMw.zip/vib20/CP048343/HPE_bootbank_CP048343_HPG4.2-7.0.0.15843807.vib","/CP048343_VMw.zip/metadata.zip/vendor-index.xml","/CP048343_VMw.zip/metadata.zip/vmware.xml","/CP048343_VMw.zip/metadata.zip/vibs/CP048343--7999903424607054505.xml","/CP048343_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048343_HPG4.2-7.0.0.15843807.xml"],"md5sum":"c0dbbb83bd1fa5344e42419986bbf4d2","name":"CP048343.zip","release":"2021-08-26T17:47:06","revision":"0","sha1sum":"d7915a4aaca254081e2f7ab79402ca0b6d16e8bf","size":"16MB","target_guids":["002340a5-4d00-3142-3030-304756595a45","002340a5-4d00-3242-3030-304756595a46","002340a5-4d00-3342-3030-304756595a48","002340a5-4d00-3442-3030-304756595a4b"],"type_of_change":"1","version":"HPG4","vib_list":[{"name":"CP048343","version":"HPG4.2-7.0.0.15843807"}]}],"id":{"product":"c33dcf4fcf5847ada8c87d0479b6cb3a","version":"471a1c101b27456b99abe7bdb3adc4c0"},"installation":{"command":"CP040554.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB1000GVYZE, MB2000GVYZF, MB3000GVYZH and MB4000GVYZK Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネントfor VMware ESXi - MB1000GVYZE、MB2000GVYZF、MB3000GVYZH、およびMB4000GVYZKドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB1000GVYZE","target_guid":"002340a5-4d00-3142-3030-304756595a45","type":"sata"},{"id":"MB2000GVYZF","target_guid":"002340a5-4d00-3242-3030-304756595a46","type":"sata"},{"id":"MB3000GVYZH","target_guid":"002340a5-4d00-3342-3030-304756595a48","type":"sata"},{"id":"MB4000GVYZK","target_guid":"002340a5-4d00-3442-3030-304756595a4b","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-06T15:51:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB3000GVYZH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB2000GVYZF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB1000GVYZE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB4000GVYZK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300374","languages":[{"lang":"fr","x_late":"Pilote - Stockage Fibre Channel"},{"lang":"en","x_late":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet"},{"lang":"cn","x_late":"驱动程序-存储光纤通道和以太网光纤通道"},{"lang":"tw","x_late":"驅動程式 - 儲存裝置光纖通道與乙太網路光纖通道"},{"lang":"de","x_late":"Treiber - Glasfaserspeicher"},{"lang":"ko","x_late":"드라이버 - 스토리지 파이버 채널 및 FCoE(Fibre Channel over Ethernet)"},{"lang":"it","x_late":"Driver - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ドライバー - ストレージ (FCおよびFCoE)"},{"lang":"es","x_late":"Controlador - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built to enable HPE Storage Fibre Channel and Mezzanine Host Bus Adapter. This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMは、HPE Storageファイバーチャネルアダプターおよびメザニンホストバスアダプターを使用可能にするためにビルド済みのバイナリドライバーモジュールを提供するために使われます。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"596234","datemodified":"2021-11-17T05:20:57","file_list":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/4.18.0-305.el8.x86_64","./lib/modules/4.18.0-305.el8.x86_64/extra","./lib/modules/4.18.0-305.el8.x86_64/extra/elx-lpfc","./lib/modules/4.18.0-305.el8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"md5sum":"bbb7328bce89a3e68235eae07eea3108","name":"kmod-elx-lpfc-12.8.528.7-1.rhel8u4.x86_64.rpm","release":"2021-11-17T05:10:15","revision":"0","sha1sum":"81748ebb2f8a5259ed727bc8bbb1b32f48148298","size":"582KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"type_of_change":"1","version":"12.8.528.7"}],"id":{"product":"a1969a6dced74b848f7c8392464ddc8c","version":"4f21f614764844a993f0425836813ff3"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>1.&nbsp;Login as the system administrator (root).</p>\n\n<p>2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p>3.&nbsp;To install or upgrade the driver, type the following command at the prompt:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -Uvh elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64.rpm<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -Uvh kmod-elx-lpfc-12.8.509.3-1.rhel8u4.x86_64.rpm</p>\n\n<p>4.&nbsp;When the installation or upgrade is complete without any failure, please reboot the server&nbsp;&nbsp;for changes to take effect.&nbsp;</p>\n\n<p><strong>IMPORTANT</strong>: If the installation fails or if you see any warning or error messages, STOP, do NOT reboot the computer. The driver will not be operational and you must uninstall the driver by typing the following command:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -e elx-lpfc-&lt;kerneltype&gt;&lt;version&gt;.&lt;OSupdate&gt;.x86_64</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Red Hat Enterprise Linux 8 Update 4 Server Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters and Mezzanine Host Bus Adapters"},{"lang":"ja","x_late":"Red Hat Enterprise Linux 8 Update 4 Serverファイバーチャネルドライバーキットfor HPE Emulexホストバスアダプターおよびメザニンホストバスアダプター"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:06:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Updated to driver version 12.8.528.7</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added the following support:</p>\n\n<ul>\n\t<li>Added support for RHEL 8.4</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>Updated to driver version 12.8.528.7</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"kmod-elx-lpfc","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWJNR and EG002400JWJNT&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"6114974","datemodified":"2021-07-23T08:31:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/CP048074.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/SSKYBT512ED6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048074.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048074.scexe"],"md5sum":"e63ac837af732d59dd91e13fbd685c43","name":"firmware-hdd-b1c9eaf74c-HPD6-2.1.x86_64.rpm","release":"2021-07-23T08:18:23","revision":"0","sha1sum":"d6f169585440342aaf25ca152a47d2be5840130f","size":"5MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"9955e8989d3a49ccb377a1c01a7b8a6c","version":"51f64f5f6595400f9178bb4a62c0765a"},"installation":{"command":"CP041696.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SDDフラッシュコンポーネント for Linux (x64) - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-22T16:16:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5716627","datemodified":"2021-08-13T14:48:04","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/CP049276.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/K401HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049276.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049276.scexe"],"md5sum":"f2e46f1ae32259168aa2e8f9109dbe15","name":"firmware-hdd-492a9952f6-HPG3-2.1.x86_64.rpm","release":"2021-08-13T14:35:05","revision":"0","sha1sum":"27bf4001cf12aee2c31a6e9529c245df5705875e","size":"5MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"fde211973c7e4009ac1207f980953529","version":"d2057c35d70840878cfc85c3b7501125"},"installation":{"command":"CP041497.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:26:03","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWFUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3030-3630-304a57465556","Version":"HPD4"},{"DeviceName":"EG001200JWFVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SELD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3230-304a57465641","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG000600JWFUV and EG001200JWFVA"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG000600JWFUV and EG001200JWFVA Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16016119","datemodified":"2021-08-30T04:02:45","file_list":["/CP048250_BUILD_2.data","/CP048250.vmexe","/CP048250.vmexe64","/CP048250.vmfile","/CP048250_VMw.zip","/CP048250.xml","/payload.json","/CP048250_VMw.zip/index.xml","/CP048250_VMw.zip/vendor-index.xml","/CP048250_VMw.zip/metadata.zip","/CP048250_VMw.zip/vib20/CP048250/HPE_bootbank_CP048250_HPD4.2-7.0.0.15843807.vib","/CP048250_VMw.zip/metadata.zip/vendor-index.xml","/CP048250_VMw.zip/metadata.zip/vmware.xml","/CP048250_VMw.zip/metadata.zip/vibs/CP048250--382686179823328467.xml","/CP048250_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048250_HPD4.2-7.0.0.15843807.xml"],"md5sum":"dcac49583a97b50142fe40e7977c8aaf","name":"CP048250.zip","release":"2021-08-30T03:58:17","revision":"0","sha1sum":"03f9be79813cc398f10cf247bfdde0b3a824b233","size":"15MB","target_guids":["452340a5-3047-3030-3630-304a57465556","452340a5-3047-3130-3230-304a57465641"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048250","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"239d1dd26f2c4614bfcd9033d0a83734","version":"32a53b800ff54bc98da59936155f031c"},"installation":{"command":"CP040635.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWFUV and EG001200JWFVA Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG000600JWFUVおよびEG001200JWFVAドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001200JWFVA","target_guid":"452340a5-3047-3130-3230-304a57465641","type":"sas"},{"id":"EG000600JWFUV","target_guid":"452340a5-3047-3030-3630-304a57465556","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T05:53:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001200JWFVA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG000600JWFUV","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"cn","x_late":"软件 - 管理"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi CRU Driver Smart Component for ESXi 7.0 includes the latest HPE CRU Driver. The HPE CRU Driver provides hardware memory and PCI Config Space access to HPE Server Configuration tools and firmware flash components."},{"lang":"ja","x_late":"HPE ESXi CRU ドライバー Smartコンポーネント for ESXi 7.0には、最新のHPE CRUドライバーが含まれています。HPE CRUドライバーは、HPEサーバー構成ツールおよびファームウェアフラッシュコンポーネントへのハードウェアメモリおよびPCI構成スペースアクセスを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]}],"documentation":[],"files":[{"bytes":"21644","datemodified":"2020-06-17T18:54:49","file_list":["/cp044598.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/vib20/cru/HPE_bootbank_cru_700.10.16-1OEM.700.0.0.14828939.vib","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vendor-index.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vmware.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/vibs/cru--3587722627266947823.xml","/cru_driver_700.10.16_1OEM.700.0.0.14828939_signed_component_15675715.zip/metadata.zip/bulletins/cru-driver_700.10.16-1OEM.700.0.0.14828939.xml"],"md5sum":"b15fcccba65f1a201e75668f7235c216","name":"cp044598.zip","release":"2020-06-17T18:54:04","revision":"0","sha1sum":"1062a6263027ebed11f844c940fdd7d86fcde628","size":"21KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecab5ae383","20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6"],"type_of_change":"1","version":"2020.04.01","vib_list":[{"name":"cru","version":"700.10.16-1OEM.700.0.0.14828939"}]}],"id":{"product":"2bca574323fb4462b57e23c3b359f69c","version":"2310590f205e43e0ae97f59492d0a40a"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the HP Smart Update Manager (HPSUM) from the HP Service Pack for ProLiant (SPP):</strong></p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>.</li>\n\t<li>Copy&nbsp;this driver component&nbsp;to the directory<em> /SPP20xxxxx/hp/swpackages</em> on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.</li>\n\t<li>Change directories to <em>/hp/swpackages</em> and execute&nbsp;./hpsum.</li>\n\t<li>Select the &quot;next&quot; button.</li>\n\t<li>Click &quot;Add Single Target.&quot;</li>\n\t<li>Enter&nbsp;the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow HP Smart Update Manager&nbsp;instructions&nbsp;to complete the driver update.</li>\n</ol>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HP Service Pack for ProLiant (SPP)からHP Smart Update Manager (HPSUM)を使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_360731071b404454b454390208\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>このドライバーコンポーネントをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。</li>\n\t<li><em>/hp/swpackages</em>にディレクトリを変更し、./hpsumを実行します。</li>\n\t<li>「次へ」ボタンを選択します。</li>\n\t<li>「シングルターゲットの追加」をクリックします。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>HP Smart Update Manager 手順に従って、ドライバーアップデートを完了します。</li>\n</ol>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE CRU Driver Bundle Smart Component for ESXi 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"16"},"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-17T18:45:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Support&nbsp;for VMware ESXi 7.0</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Add new supported servers</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"I39","value":"HPE Synergy 660 Gen9 Compute Module"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I37","value":"HPE Synergy 480 Gen9 Compute Module"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru-driver:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"cru:700.10.16-1OEM.700.0.0.14828939","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK0120GFDKE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3132-304746444b45","Version":"HPG1"},{"DeviceName":"VK0240GFDKF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3234-304746444b46","Version":"HPG1"},{"DeviceName":"VK0480GFDKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3438-304746444b48","Version":"HPG1"},{"DeviceName":"VK0960GFDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-304b-3936-304746444b4b","Version":"HPG1"},{"DeviceName":"VK1920GFDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-314b-3932-304746444b4c","Version":"HPG1"},{"DeviceName":"VK3840GFDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GPM863G1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-5600-334b-3834-304746444b4e","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp; &nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"2784720","datemodified":"2021-07-25T19:15:32","file_list":["cp048641.xml","cpqsetup.exe","GPM863G1.rel","payload.json","setup.dll"],"md5sum":"553eadb759586865d0f2566181a9f830","name":"cp048641.exe","release":"2021-07-25T19:08:04","revision":"0","sha1sum":"453080f87a0eeb70260d5b2fdebc395ae8c83c48","size":"2MB","target_guids":["002340a5-5600-304b-3132-304746444b45","002340a5-5600-304b-3234-304746444b46","002340a5-5600-304b-3438-304746444b48","002340a5-5600-304b-3936-304746444b4b","002340a5-5600-314b-3932-304746444b4c","002340a5-5600-334b-3834-304746444b4e"],"type_of_change":"1","version":"HPG1"}],"id":{"product":"3aebaee5a0504648985c2d89d7e4e8d9","version":"e01d85bf4bd649d4a9d3adc6e928d1db"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - VK0120GFDKE, VK0240GFDKF, VK0480GFDKH, VK0960GFDKK, VK1920GFDKL and VK3840GFDKN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - VK0120GFDKE、VK0240GFDKF、VK0480GFDKH、VK0960GFDKK、VK1920GFDKL、およびVK3840GFDKNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"VK0120GFDKE","target_guid":"002340a5-5600-304b-3132-304746444b45","type":"sata"},{"id":"VK1920GFDKL","target_guid":"002340a5-5600-314b-3932-304746444b4c","type":"sata"},{"id":"VK0240GFDKF","target_guid":"002340a5-5600-304b-3234-304746444b46","type":"sata"},{"id":"VK3840GFDKN","target_guid":"002340a5-5600-334b-3834-304746444b4e","type":"sata"},{"id":"VK0480GFDKH","target_guid":"002340a5-5600-304b-3438-304746444b48","type":"sata"},{"id":"VK0960GFDKK","target_guid":"002340a5-5600-304b-3936-304746444b4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T17:22:33","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK0960GFDKK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0120GFDKE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0480GFDKH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK1920GFDKL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK3840GFDKN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK0240GFDKF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true},{"DelayAfterInstallSec":180,"DirectFlashOk":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":true}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0118"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This package updates the I/O module firmware on HPE D8000 Disk Enclosures attached to supported HPE Storage Controllers and Host Bus Adapters"},{"lang":"ja","x_late":"このパッケージは、サポートされたHPEストレージコントローラーおよびホストバスアダプターに接続されたHPE D8000ディスクエンクロージャーのI/Oモジュールファームウェアをアップデートします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"15008264","datemodified":"2021-12-08T15:20:53","file_list":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff","Config.xml","cp050053.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"md5sum":"e7b5d1ffa4a1c1c867662d377c222b1b","name":"cp050053.exe","release":"2021-12-08T15:18:41","revision":"0","sha1sum":"9563f6c38d39eb7885fd5e3e25b95e5af6de1dd3","size":"14MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"type_of_change":"1","version":"0118"}],"id":{"product":"33474bdb31ec42199bc00637b81a4d15","version":"159b47b6711d4c7bbac8986c5ebe1859"},"installation":{"command":"cpqsetup.exe","command_params":"/t D8000 /v 0118 /i 93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.13.0.gff /i 93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.13.0.gff /l D8000.log","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":900,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>Windows Smart Component Installation Instructions:</strong></p>\n\n<p>This is a self extracting executable module. One can execute this module via the&nbsp;command line console or from&nbsp;Windows graphical user interface.</p>\n\n<p><strong>GUI Option:</strong></p>\n\n<ol>\n\t<li>Place the downloaded firmware package in a temporary directory.</li>\n\t<li>Using Windows Explorer, navigate to the directory containing the download.</li>\n\t<li>Double click the executable file.</li>\n\t<li>Follow onscreen instructions.After you are prompted for logon information, enter credentials for an account with management access rights.</li>\n</ol>\n\n<p><strong>CLI Option:</strong></p>\n\n<p>Execute the Smart Component by entering the following command: CP0xxxxx.exe /s</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager (SUM) from the Service Pack for ProLiant (SPP):</strong></p>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages.</li>\n\t<li>Run the launch_sum.bat in the root of the ISO.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n\n<p><strong>NOTES: </strong>OPTIONS for in band enclosure flash:</p>\n\n<p><strong>Parameter</strong> &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<strong>Description</strong><br />\n-----------------------------------------------------------------------------<br />\n<strong>/h,/?&nbsp;</strong>&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;Displays command line usage help(dialog box)<br />\n<strong>/s </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Installs without user interaction</p>\n\n<p><strong>The following command&nbsp;is&nbsp;applicable only with /s:</strong><br />\n<strong>/f </strong>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Allow a downgrade or reinstall if already up to date</p>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)"},{"lang":"ja","x_late":"HPE D8000 12 Gb SASディスクエンクロージャーROMフラッシュコンポーネントfor Windows (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"2"},"supported_devices":[{"id":"D8000 12Gb Enclosure","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"},{"id":"D8000 12Gb IO","target_guid":"b99dfb74-f0bc-464f-b418-cd1857b65875","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-23T12:08:02","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p><strong>The following fixes were&nbsp;incorporated in this version:</strong></p>\n\n<ul>\n\t<li>\n\t<p>User was not able to collect ddump logs.</p>\n\t</li>\n\t<li>\n\t<p>Logical Fault LED remains ON even after clearing the fault using &quot;reboot soft&quot;.</p>\n\t</li>\n\t<li>\n\t<p>Vendor ID showed as &quot;DEFAULT&quot; for D8000 expander in SSACLI enclosure detail.</p>\n\t</li>\n\t<li>\n\t<p>Fixes a problem where after upgrade, drives in slots 1 &ndash; 96 may not appear.</p>\n\t</li>\n</ul>\n\n<p>Please refer to the&nbsp;<a href=\"https://downloads.hpe.com/pub/softlib2/software1/pubsw-linux/p480571592/v203448/20-D8000-Gen10RN0118_ED1.html\"><u>Release Notes</u></a>&nbsp;for the complete listing of fixes, enhancements, known issues and work-arounds corresponding to this firmware.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"D8000","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK000200GWEPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3230-304757455044","Version":"HPG3"},{"DeviceName":"EK000400GWEPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3430-304757455045","Version":"HPG3"},{"DeviceName":"EK000800GWEPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3030-3830-304757455046","Version":"HPG3"},{"DeviceName":"EK001600GWEPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS865aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304b-3130-3630-304757455048","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPFand EK001600GWEPH Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2810008","datemodified":"2021-07-24T05:02:46","file_list":["cp048554.xml","cpqsetup.exe","GS865aG3.rel","payload.json","setup.dll"],"md5sum":"6be83a8e622de3e3167e8b5e89fb587b","name":"cp048554.exe","release":"2021-07-24T04:55:04","revision":"0","sha1sum":"b00b8417f156c66cacd975118f8bbc917a778700","size":"2MB","target_guids":["452340a5-304b-3030-3230-304757455044","452340a5-304b-3030-3430-304757455045","452340a5-304b-3030-3830-304757455046","452340a5-304b-3130-3630-304757455048"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"249ebde928b24f7cb7ebdd3c20053940","version":"8535c17f50464add8ef2d199a6ba64a0"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EK000200GWEPD, EK000400GWEPE, EK000800GWEPF and EK001600GWEPH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - EK000200GWEPD、EK000400GWEPE、EK000800GWEPFおよびEK001600GWEPHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EK000400GWEPE","target_guid":"452340a5-304b-3030-3430-304757455045","type":"sata"},{"id":"EK000800GWEPF","target_guid":"452340a5-304b-3030-3830-304757455046","type":"sata"},{"id":"EK001600GWEPH","target_guid":"452340a5-304b-3130-3630-304757455048","type":"sata"},{"id":"EK000200GWEPD","target_guid":"452340a5-304b-3030-3230-304757455044","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T05:02:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK000800GWEPF","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000400GWEPE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK000200GWEPD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"EK001600GWEPH","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH0300JEDHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3330-304a45444843","Version":"HPD4"},{"DeviceName":"EH0450JEDHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3435-304a45444844","Version":"HPD4"},{"DeviceName":"EH0600JEDHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SVKBPND4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-3048-3630-304a45444845","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH0300JEDHC, EH0450JEDHD, and EH0600JEDHE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します。 EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD&nbsp;and EH0600JEDHE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3542112","datemodified":"2021-07-24T05:23:00","file_list":["cp048520.xml","cpqsetup.exe","payload.json","setup.dll","SVKBPND4.rel"],"md5sum":"b91721019b6369e5682cb0e2dc7cb83f","name":"cp048520.exe","release":"2021-07-24T05:15:04","revision":"0","sha1sum":"8bdc399a57e8a32f495280eb6c3225838abd094a","size":"3MB","target_guids":["002340a5-4500-3048-3330-304a45444843","002340a5-4500-3048-3435-304a45444844","002340a5-4500-3048-3630-304a45444845"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"33a82ad709014bf88daa4d5451b9b3d6","version":"894bef47854a465fb0062fe9e66db032"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - EH0300JEDHC, EH0450JEDHD and EH0600JEDHE Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows(x64)- EH0300JEDHC、EH0450JEDHD、およびEH0600JEDHEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"EH0300JEDHC","target_guid":"002340a5-4500-3048-3330-304a45444843","type":"sas"},{"id":"EH0450JEDHD","target_guid":"002340a5-4500-3048-3435-304a45444844","type":"sas"},{"id":"EH0600JEDHE","target_guid":"002340a5-4500-3048-3630-304a45444845","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-15T10:35:01","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH0600JEDHE","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0300JEDHC","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH0450JEDHD","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GEXXV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRETG2.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304745585856","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GEXXV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp;</strong> None</p>\n"}],"files":[{"bytes":"3396136","datemodified":"2021-07-25T18:14:11","file_list":["cp048633.xml","cpqsetup.exe","payload.json","setup.dll","TTMRETG2.REL"],"md5sum":"06707539232732b4b5bbeca98ecf6f66","name":"cp048633.exe","release":"2021-07-25T18:07:11","revision":"0","sha1sum":"92b015b0b0d296b84ea49e4f559f5e0ea1115e8d","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304745585856"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"835ec029c284401691cf43baf128212e","version":"c9510f3ac6f24818a7c8e28aa8c0b6c4"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GEXXV Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GEXXVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GEXXV","target_guid":"002340a5-4d00-3642-3030-304745585856","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T14:42:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GEXXV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel icea Gigabit Ethernet NICs running under VMware vSphere 6.7"},{"lang":"ja","x_late":"このコンポーネントパッケージには、VMware vSphere 6.7で動作するHPE Intel icea Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.6.2.0.</p>\n"},{"lang":"ja","x_late":"<p>この製品には、ドライバーバージョン1.6.2.0が含まれています。</p>\n"}],"files":[{"bytes":"506851","datemodified":"2022-01-25T05:39:51","file_list":["/cp050787.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/index.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/vendor-index.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/metadata.zip","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/vib20/icen/INT_bootbank_icen_1.7.3.0-1OEM.670.0.0.8169922.vib","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/metadata.zip/vendor-index.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/metadata.zip/vmware.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/metadata.zip/vibs/icen-4851155567140199977.xml","/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922-offline_bundle-18990249.zip/metadata.zip/bulletins/Intel-icen_1.7.3.0-1OEM.670.0.0.8169922.xml"],"md5sum":"2c35221d9fb60c8da84697c916b0e9d5","name":"cp050787.zip","release":"2022-01-25T05:39:40","revision":"0","sha1sum":"5ce90ddf5ef3f56f454acf1a80fcd9de08384e34","size":"494KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"type_of_change":"1","version":"2022.03.23","vib_list":[{"name":"icen","version":"1.7.3.0-1OEM.670.0.0.8169922"}]}],"id":{"product":"a9a34047456048c2a78acc4ebffa4383","version":"586082cd53c44d92a4d06b597df26eca"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバー上のUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Intel icea Driver for VMware vSphere 6.7"},{"lang":"ja","x_late":"Intel icea ドライバーfor VMware vSphere 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"1592","subdev":"0002","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860002","type":"pci","ven":"8086"},{"dev":"1592","subdev":"0006","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159280860006","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0003","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860003","type":"pci","ven":"8086"},{"dev":"159B","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159b80860005","type":"pci","ven":"8086"},{"dev":"1593","subdev":"0005","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-159380860005","type":"pci","ven":"8086"},{"dev":"1592","subdev":"000E","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15928086000e","type":"pci","ven":"8086"},{"dev":"1593","subdev":"000C","subven":"8086","target_guid":"a6b1a447-382a-5a4f-8086-15938086000c","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-02-14T02:22:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with <em>Intel Firmware Package For E810 Ethernet Adapter</em> (PLDM)&nbsp;&nbsp;version 3.10.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"","value":"HPE Edgeline EL8000 Converged Edge System"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"","value":"HPE Edgeline EL8000t Converged Edge System"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"}],"sw_keys":[{"name":"icen:1.7.3.0-1OEM.670.0.0.8169922","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built\nfor SUSE LINUX Enterprise Server 15 64-bit to enable the HPE Smart Array P824i-p MR controller. This RPM provides a customer friendly approach to install a pre-built binary driver."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"666511","datemodified":"2019-01-23T06:22:19","file_list":["./lib/modules/4.12.14-23-default","./lib/modules/4.12.14-23-default/updates","./lib/modules/4.12.14-23-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"md5sum":"37d156f6a122f3df3d3debe104547425","name":"lsi-megaraid_sas-kmp-default-07.706.05.00-14.sles15sp0.x86_64.rpm","release":"2019-01-23T06:23:01","revision":"0","sha1sum":"346ebcc5fc7eacf5549357377ee80ed554320a1b","size":"650KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"type_of_change":"1","version":"07.706.05.00-14"}],"id":{"product":"064d24a671684c77b993cf50aaac78a7","version":"ff3d86a5886a4a78b2b033fccd5d4745"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh lsi-megaraid_sas-kmp-default-X.X.X.X-X.sles15spX.x86_64.rpm (X.X.X.X-X represents the version number and spX represents the OS update)<br />\n<br />\nA REBOOT is required for your computer when the setup is complete.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE Smart Array P824i-p MR controller Driver for 64-bit SUSE LINUX Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"00CF","subdev":"022C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-00cf1590022c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2018-12-22T09:32:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Added support for Microsoft Windows Server 2019.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added ProLiant features support (Megacell status, AHS, Spade, Sanitize &amp; Expander)</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"lsi-megaraid_sas-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800026","languages":[{"lang":"tw","x_late":"軟體 - 管理"},{"lang":"en","x_late":"Software - Management"},{"lang":"ko","x_late":"소프트웨어 - 관리"},{"lang":"ja","x_late":"ソフトウェア - マネジメント"},{"lang":"cn","x_late":"软件 - 管理"}]}],"description":[{"lang":"en","x_late":"The HPE ESXi Management Smart Component for ESXi 6.7 includes the latest Agentless Management Service (AMS), HPE Integrated Lights-Out (iLO) driver, HPE Compaq ROM Utility (CRU) driver, and Fibre Channel(FC) HBA access libraries."},{"lang":"ja","x_late":"HPE ESXi Management Smartコンポーネントfor ESXi 6.7には、最新のAgentless Management Service（AMS）、HPE Integrated Lights-Out（iLO）ドライバー、HPE Compaq ROM Utility（CRU）ドライバー、ファイバーチャネル（FC）HBAアクセスライブラリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"13275293","datemodified":"2021-09-11T08:48:59","file_list":["/cp047522.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/index.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vendor-index.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/amsd-670.11.8.0.15-1.7535516.vib","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/ilo_670.10.7.5.2-1OEM.670.0.0.7535516.vib","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/fc-enablement-670.3.80.6-7535516.vib","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/cru_670.6.7.10.14-1OEM.670.0.0.7535516.vib","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vendor-index.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vmware.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vibs/amsd--4684364654317494903.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vibs/ilo-2964936189223017316.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vibs/fc-enablement-8460638345289256901.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/vibs/cru--1581854872647123919.xml","/ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/metadata-ams-esxi6.7-bundle-gen10.11.8.0.15-1.zip/bulletins/ams-esxi6.7-bundle-gen10.11.8.0.15-1.xml"],"md5sum":"846e6312ceef9efc24dcfdccec776cbb","name":"cp047522.zip","release":"2021-10-22T00:00:00","revision":"1","sha1sum":"bf466e2e2f8217a0cc46c10eb104a3667dd92b58","size":"12MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","20a6e8e4-bf33-4c71-a6bf-d9ecb46a2f45","20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"amsd","version":"670.11.8.0.15-1.7535516"},{"name":"ilo","version":"670.10.7.5.2-1OEM.670.0.0.7535516"},{"name":"fc-enablement","version":"670.3.80.6-7535516"},{"name":"cru","version":"670.6.7.10.14-1OEM.670.0.0.7535516"}]}],"id":{"product":"424586858da54235abb9a96e632bc309","version":"1143b196e6324c86a14518b45431c44a"},"installation":{"command":"","command_params":"maintenancemode=false","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To&nbsp;remotely install&nbsp;this&nbsp;bundle&nbsp; online using the Smart Update Manager&nbsp;from the HPE Service Pack for ProLiant:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the smart component zip file to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><br />\n<strong>To&nbsp;install this bundle using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the component zip file to extract the driver offline bundle.</li>\n\t<li>Run the &quot;esxcli&quot; commands to install the offline bundle.</li>\n</ol>\n\n<p>Refer to VMware documentation for information on the esxcli commands</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantからSmart Update Managerを使用して、このバンドルをオンラインでリモートインストールするには：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにsmartコンポーネントzipファイルを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報（rootまたは管理者ユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p><br />\n<strong>VMwareツールを使用して、このバンドルをインストールするには：</strong></p>\n\n<ol>\n\t<li>ドライバーオフラインバンドルを抽出するために、このコンポーネントのzipファイルを解凍します。</li>\n\t<li>オフラインバンドルをインストールするには、「esxcli」コマンドを実行します。</li>\n</ol>\n\n<p>esxcliコマンドの詳細については、VMwareのドキュメントを参照してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Management Bundle Smart Component for ESXi 6.7 for Gen10 and Gen10 Plus Servers"},{"lang":"ja","x_late":"HPE Management Bundle Smartコンポーネントfor ESXi 6.7 for Gen10およびGen10 Plusサーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"31000"},"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-01T22:29:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload and when Quickboot is enabled</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Added support for new cpqIdeAtaDiskCapacityHighBytes and cpqIdeAtaDiskCapacityLowBytes MIB OIDs</li>\n\t<li>Added support for hrSystemUptime MIB OID</li>\n\t<li>Added support for cpqIdeAtaDiskSSDWearStatusChange trap</li>\n\t<li>Added support for&nbsp;Pensando NIC devices</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Agentless Management Service</strong></p>\n\n<ul>\n\t<li>Fix excessive poll failure logging on iLO reset</li>\n\t<li>Applied fixes to net-snmp open source code for CVE-2018-18065, CVE-2018-18066, CVE-2015-5621</li>\n</ul>\n\n<p><strong>iLO Driver</strong></p>\n\n<ul>\n\t<li>Fixed driver unload function to allow controller to function properly on reload and when Quickboot is enabled</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"H09","value":"HPE ProLiant m750 Server Blade"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"cru:670.6.7.10.14-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"ilo:670.10.7.5.2-1OEM.670.0.0.7535516","sw_key_expectedpath":"driver:vmware:zip"},{"name":"fc-enablement:670.3.80.6-7535516","sw_key_expectedpath":"software:vmware:zip"},{"name":"amsd:670.11.8.0.15-1.7535516","sw_key_expectedpath":"software:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAnAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: MB004000JWKGU"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB004000JWKGU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"18758157","datemodified":"2021-08-30T20:02:06","file_list":["/CP048321_BUILD_2.data","/CP048321.vmexe","/CP048321.vmexe64","/CP048321.vmfile","/CP048321_VMw.zip","/CP048321.xml","/payload.json","/CP048321_VMw.zip/index.xml","/CP048321_VMw.zip/vendor-index.xml","/CP048321_VMw.zip/metadata.zip","/CP048321_VMw.zip/vib20/CP048321/HPE_bootbank_CP048321_HPD2.2-7.0.0.15843807.vib","/CP048321_VMw.zip/metadata.zip/vendor-index.xml","/CP048321_VMw.zip/metadata.zip/vmware.xml","/CP048321_VMw.zip/metadata.zip/vibs/CP048321-6459550740057422470.xml","/CP048321_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048321_HPD2.2-7.0.0.15843807.xml"],"md5sum":"81c70eaf9bb042feef42361a07b21509","name":"CP048321.zip","release":"2021-08-30T19:56:49","revision":"0","sha1sum":"3b6ed62200c73ee8f394632ff3c2e86f0d8a915d","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a574b4755"],"type_of_change":"1","version":"HPD2","vib_list":[{"name":"CP048321","version":"HPD2.2-7.0.0.15843807"}]}],"id":{"product":"787f189347ac420fbe52f5e6292d569d","version":"1dd0b933ff2848d1862028b3dcc7dd99"},"installation":{"command":"CP041492.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWKGUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWKGU","target_guid":"4d2340a5-3042-3430-3030-304a574b4755","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T12:36:47","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWKGU","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000400KWDUK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3430-304b5744554b","Version":"HPK4"},{"DeviceName":"VK000480KWDUE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304b57445545","Version":"HPK4"},{"DeviceName":"MK000800KWDUL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b5744554c","Version":"HPK4"},{"DeviceName":"VK000960KWDUF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304b57445546","Version":"HPK4"},{"DeviceName":"MK001600KWDUN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b5744554e","Version":"HPK4"},{"DeviceName":"VK001920KWDUH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"spannsK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304b57445548","Version":"HPK4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online NVMe SSD&nbsp;Flash Component for VMware ESXi -&nbsp;MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN&nbsp;and VK001920KWDUH Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;HPK4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"22807301","datemodified":"2021-08-31T04:15:14","file_list":["/CP048486_BUILD_2.data","/CP048486.vmexe","/CP048486.vmexe64","/CP048486.vmfile","/CP048486_VMw.zip","/CP048486.xml","/payload.json","/CP048486_VMw.zip/index.xml","/CP048486_VMw.zip/vendor-index.xml","/CP048486_VMw.zip/metadata.zip","/CP048486_VMw.zip/vib20/CP048486/HPE_bootbank_CP048486_HPK4.2-7.0.0.15843807.vib","/CP048486_VMw.zip/metadata.zip/vendor-index.xml","/CP048486_VMw.zip/metadata.zip/vmware.xml","/CP048486_VMw.zip/metadata.zip/vibs/CP048486--3255339833109693147.xml","/CP048486_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048486_HPK4.2-7.0.0.15843807.xml"],"md5sum":"04c181dfac8a39c5f0d731adb9892a68","name":"CP048486.zip","release":"2021-08-31T04:09:47","revision":"0","sha1sum":"413364a68fd1b1e371635059d32810d48b8bf544","size":"21MB","target_guids":["4d2340a5-304b-3030-3430-304b5744554b","562340a5-304b-3030-3438-304b57445545","4d2340a5-304b-3030-3830-304b5744554c","562340a5-304b-3030-3936-304b57445546","4d2340a5-304b-3130-3630-304b5744554e","562340a5-304b-3130-3932-304b57445548"],"type_of_change":"1","version":"HPK4","vib_list":[{"name":"CP048486","version":"HPK4.2-7.0.0.15843807"}]}],"id":{"product":"116d422873c94edd9b2d0af192be21c4","version":"910185cb75654051a8f0e72302b260fe"},"installation":{"command":"CP040919.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for VMware ESXi  - MK000400KWDUK, VK000480KWDUE, MK000800KWDUL, VK000960KWDUF, MK001600KWDUN and VK001920KWDUH Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor VMware ESXi - MK000400KWDUK、VK000480KWDUE、MK000800KWDUL、VK000960KWDUF、MK001600KWDUN、およびVK001920KWDUHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MK000400KWDUK","target_guid":"4d2340a5-304b-3030-3430-304b5744554b","type":"nvme"},{"id":"MK000800KWDUL","target_guid":"4d2340a5-304b-3030-3830-304b5744554c","type":"nvme"},{"id":"MK001600KWDUN","target_guid":"4d2340a5-304b-3130-3630-304b5744554e","type":"nvme"},{"id":"VK000480KWDUE","target_guid":"562340a5-304b-3030-3438-304b57445545","type":"nvme"},{"id":"VK000960KWDUF","target_guid":"562340a5-304b-3030-3936-304b57445546","type":"nvme"},{"id":"VK001920KWDUH","target_guid":"562340a5-304b-3130-3932-304b57445548","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-14T08:11:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000960KWDUF","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK001920KWDUH","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000800KWDUL","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK001600KWDUN","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MK000400KWDUK","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VK000480KWDUE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Plus Backplane Expander"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Plus Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; NA<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Initial Release</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5408530","datemodified":"2021-01-26T18:21:50","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/CP046385.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP046385.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP046385.scexe"],"md5sum":"f394898b0fa6c3a21e79e93075f7dcde","name":"firmware-smartarray-7b5e8400dd-1.27-1.1.x86_64.rpm","release":"2021-01-26T18:03:04","revision":"0","sha1sum":"87a41837b71553028ff4ae1ef08ded11ba69bfb4","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"type_of_change":"1","version":"1.27"}],"id":{"product":"b94490ecb4854ca6989ed2491e061c4b","version":"24d2af3292a346209305cb8ad90a068a"},"installation":{"command":"CP046385.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP046385.scexe&nbsp;script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP046385.scexe&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-7b5e8400dd-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"id":"Apollon2800Gen10Plus","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-01-03T13:04:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"}],"sw_keys":[{"name":"Capitola","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Apollo 2000 G10P","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MT001600KWHAC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3130-3630-304b57484143","Version":"HPK1"},{"DeviceName":"MT003200KWHAD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3330-3230-304b57484144","Version":"HPK1"},{"DeviceName":"MT006400KWHAE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP1725K1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3054-3630-3430-304b57484145","Version":"HPK1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MT001600KWHAC, MT003200KWHAD and MT006400KWHAE"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - &nbsp;MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n"}],"files":[{"bytes":"6884127","datemodified":"2021-12-21T07:37:38","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/CP050490.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/GP1725K1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e8ddc5265-HPK1-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050490.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050490.scexe"],"md5sum":"7587511e6bac8114697c8021a88bbd9e","name":"firmware-hdd-8e8ddc5265-HPK1-3.1.x86_64.rpm","release":"2021-12-21T07:22:43","revision":"0","sha1sum":"63d2756863c664d0230ebebfd8bbecfd24723857","size":"6MB","target_guids":["4d2340a5-3054-3130-3630-304b57484143","4d2340a5-3054-3330-3230-304b57484144","4d2340a5-3054-3630-3430-304b57484145"],"type_of_change":"2","version":"HPK1"}],"id":{"product":"0d61f1ea72cf4d4991d4093a05f8808a","version":"6e58c5e471724a989c1dd11404bb07d9"},"installation":{"command":"CP040131.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li><em>rpm -ivhコマンドを使用して、ファームウェアrpmをインストールします。 </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。'firmware-hdd--*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするには、以下のコマンドの<strong>1つ</strong>を実行します:\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションで<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、<em>rpm -e</em>コマンドを実行します。これは.rpm'拡張子なしのrpmファイル名です。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li><em>rpm2cpio .rpm | cpio -idコマンドを使用してrpmの内容を抽出します。 </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-hdd--*'ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。'firmware-hdd--*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります)</li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - MT001600KWHAC, MT003200KWHAD and MT006400KWHAE Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - MT001600KWHAC、MT003200KWHAD、およびMT006400KWHAEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MT006400KWHAE","target_guid":"4d2340a5-3054-3630-3430-304b57484145","type":"nvme"},{"id":"MT003200KWHAD","target_guid":"4d2340a5-3054-3330-3230-304b57484144","type":"nvme"},{"id":"MT001600KWHAC","target_guid":"4d2340a5-3054-3130-3630-304b57484143","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-21T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>Firmware corrects an issue where the drive will be in a failed state after an unexpected power loss. When this occurs the drive will not recover after subsequent power cycles and will not be accessible by the system configuration and Host applications.</li>\n\t<li>Refer Customer Bulletin for workarounds&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00042733en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MT003200KWHAD","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT001600KWHAC","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"MT006400KWHAE","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEQNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45514e4c","Version":"HPDB"},{"DeviceName":"MB6000JEQNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HAKPSCDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45514e4e","Version":"HPDB"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following SAS drive models: MB4000JEQNL and MB6000JEQNN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のSASドライブモデルのファームウェアを提供します。 MB4000JEQNLおよびMB6000JEQNN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPDB<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5553580","datemodified":"2021-07-23T07:22:11","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/CP048164.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/HAKPSCDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2cfaac41db-HPDB-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048164.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048164.scexe"],"md5sum":"ef3176221c6d8ebdb98f5bc89b4ac0b7","name":"firmware-hdd-2cfaac41db-HPDB-8.1.x86_64.rpm","release":"2021-07-23T07:09:12","revision":"0","sha1sum":"09b8a30f7c6914458e7f9dd2e2f551ee106e01f9","size":"5MB","target_guids":["002340a5-4d00-3442-3030-304a45514e4c","002340a5-4d00-3642-3030-304a45514e4e"],"type_of_change":"1","version":"HPDB"}],"id":{"product":"57f299c4757147d2a235078cf35bab3f","version":"a9db5f24802e45cea91b7cb3f0eabee0"},"installation":{"command":"CP040264.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB4000JEQNL and MB6000JEQNN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB4000JEQNLおよびMB6000JEQNNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"id":"MB4000JEQNL","target_guid":"002340a5-4d00-3442-3030-304a45514e4c","type":"sas"},{"id":"MB6000JEQNN","target_guid":"002340a5-4d00-3642-3030-304a45514e4e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-27T19:22:24","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB4000JEQNL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB6000JEQNN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This RPM is used to provide binary driver modules that have been pre-built for Red Hat Enterprise Linux 7 64-bit to enable the HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller.  This RPM provides a customer friendly approach to install a pre-built binary driver."},{"lang":"ja","x_late":"このRPMを使用して、HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラーを有効にする、64ビットRed Hat Enterprise Linux 7用のビルド済みバイナリドライバーモジュールを提供します。このRPMは、ユーザーが容易にインストールできるビルド済みバイナリドライバーを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"796036","datemodified":"2021-09-07T08:59:53","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-1160.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"00042f1536fc835bb5843ac9019ef425","name":"kmod-megaraid_sas-07.716.02.00-1.rhel7u9.x86_64.rpm","release":"2021-09-07T08:48:44","revision":"0","sha1sum":"0e3b25807e735d985425f2adc0ebab40af212a58","size":"777KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"},{"bytes":"795385","datemodified":"2021-09-07T09:01:14","file_list":["./etc/depmod.d/megaraid_sas.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/megaraid_sas","./lib/modules/3.10.0-1127.el7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"md5sum":"1cedaf58cd11989f147c14667aa66d54","name":"kmod-megaraid_sas-07.716.02.00-1.rhel7u8.x86_64.rpm","release":"2021-09-07T08:48:44","revision":"0","sha1sum":"7f3dd6fc3cb8f773a533a52e1c80e7f46f441ed9","size":"776KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"type_of_change":"1","version":"07.716.02.00"}],"id":{"product":"35899789a3884097b1355c74c1f6e789","version":"54b93a576df44bafbdf9684ac788ecc8"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To install the driver, type the following command:<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)<br />\n<br />\nTo upgrade the driver, type the following command:<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm (X.X.X.X-X represents the version number and uX represents the OS update)</p>\n\n<p>A REBOOT is required for your computer when the setup is complete.</p>\n"},{"lang":"ja","x_late":"<p>ドライバーをインストールするには、次のコマンドを入力します。<br />\n# rpm -ivh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）<br />\n<br />\nドライバーをアップグレードするには、次のコマンドを入力します。<br />\n# rpm -Uvh kmod-megaraid_sas-X.X.X.X-X.rhel7uX.x86_64.rpm（X.X.X.X-Xはバージョン番号を、uXはOSアップデート番号を表します）</p>\n\n<p>セットアップが完了したらコンピューターをリブートする必要があります。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"LSI Logic Corporation"}],"name":[{"lang":"en","x_late":"HPE MR416i-a, MR416i-p, MR216i-a, MR216i-p controller Driver for 64-bit Red Hat Enterprise Linux 7"},{"lang":"ja","x_late":"HPE MR416i-a、MR416i-p、MR216i-a、MR216i-pコントローラードライバーfor 64-bit Red Hat Enterprise Linux 7"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-23T14:34:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial Release</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"},{"name":"kmod-megaraid_sas","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPD7"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPD7"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SKESTND7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EH000300JWCPK, EH000600JWCPL and EH000900JWCPN"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi -&nbsp;&nbsp;EH000300JWCPK, EH000600JWCPL&nbsp;and EH000900JWCPN Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"17750356","datemodified":"2021-08-30T06:21:33","file_list":["/CP048286_BUILD_2.data","/CP048286.vmexe","/CP048286.vmexe64","/CP048286.vmfile","/CP048286_VMw.zip","/CP048286.xml","/payload.json","/CP048286_VMw.zip/index.xml","/CP048286_VMw.zip/vendor-index.xml","/CP048286_VMw.zip/metadata.zip","/CP048286_VMw.zip/vib20/CP048286/HPE_bootbank_CP048286_HPD7.2-7.0.0.15843807.vib","/CP048286_VMw.zip/metadata.zip/vendor-index.xml","/CP048286_VMw.zip/metadata.zip/vmware.xml","/CP048286_VMw.zip/metadata.zip/vibs/CP048286-9124546134892661025.xml","/CP048286_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048286_HPD7.2-7.0.0.15843807.xml"],"md5sum":"2a8501d4a382d41a6ec64b1d7ca36f74","name":"CP048286.zip","release":"2021-08-30T06:15:41","revision":"0","sha1sum":"4126fa6a0869a026c12df59767c4bf23fb614a67","size":"16MB","target_guids":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e"],"type_of_change":"1","version":"HPD7","vib_list":[{"name":"CP048286","version":"HPD7.2-7.0.0.15843807"}]}],"id":{"product":"070f2ccb66ec4478ba85a2e3d9712434","version":"3d210b2ffb594aeb8cfae9a249d9222c"},"installation":{"command":"CP040541.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン：</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL and EH000900JWCPN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EH000300JWCPK、EH000600JWCPL、およびEH000900JWCPNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EH000300JWCPK","target_guid":"452340a5-3048-3030-3330-304a5743504b","type":"sas"},{"id":"EH000600JWCPL","target_guid":"452340a5-3048-3030-3630-304a5743504c","type":"sas"},{"id":"EH000900JWCPN","target_guid":"452340a5-3048-3030-3930-304a5743504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-03T05:17:35","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000300JWCPK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000900JWCPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWCPL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the vxn driver for HPE Intel ixn and ixt 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixnおよびixt 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"960352","datemodified":"2021-11-02T08:27:42","file_list":["cp047054.xml","cpqsetup.exe","cp_data.xml","install.xml","NicCo5.dll","nicdrvr.dll","NicInVXN.dll","vxn65x64.cat","vxn65x64.din","vxn65x64.inf","vxn65x64.sys","vxnmsg.dll"],"md5sum":"403dd27477a7a9723be46c62327544fa","name":"cp047054.exe","release":"2021-11-02T08:13:35","revision":"0","sha1sum":"6edda45198af7fb6c53e8751729f9433815cd230","size":"937KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec076f9a7c"],"type_of_change":"0","version":"2.1.243.0"}],"id":{"product":"8580226958cf4ea0a4c511ccdfa9e081","version":"a8d2a4ffab9a45adb05159ab62d3b04e"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel vxn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel vxnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"211B","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c211b","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\">This product now&nbsp; supports the following the network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HPE Ethernet 10Gb 2-port 561FLR-T Adapter</li>\n\t<li>HPE Ethernet 10Gb 2-port 561T Adapter</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInVXN.dll and vxnmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"}],"sw_keys":[{"name":"vxn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD6"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNESD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB008000JWWQPおよびMB006000JWWQNドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- MB008000JWWQP and MB006000JWWQN Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD2<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5913115","datemodified":"2021-07-23T09:16:08","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/CP048200.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/SCIMARRNESD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048200.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048200.scexe"],"md5sum":"c3e6fbe9b2df49b2a6f169d791d753aa","name":"firmware-hdd-ae6b41e855-HPD6-2.1.x86_64.rpm","release":"2021-07-23T09:04:11","revision":"0","sha1sum":"bccb01c532789c3e9e2eed7183d52e586db85287","size":"5MB","target_guids":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"type_of_change":"1","version":"HPD6"}],"id":{"product":"f66d2f40fe3b49a2ae22ce155e429f5c","version":"60a417fc8d944f3d9919c79396792746"},"installation":{"command":"CP043258.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - MB008000JWWQPおよびMB006000JWWQNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB006000JWWQN","target_guid":"4d2340a5-3042-3630-3030-304a5757514e","type":"sas"},{"id":"MB008000JWWQP","target_guid":"4d2340a5-3042-3830-3030-304a57575150","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:10:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWWQP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWWQN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5433440","datemodified":"2021-09-09T20:24:48","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/CP049504.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049504.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049504.scexe"],"md5sum":"cb1cfee10967bf7c6d2951df31175cd5","name":"firmware-smartarray-f36d4ef431-0.39-2.1.x86_64.rpm","release":"2021-09-09T20:10:30","revision":"0","sha1sum":"eb82688d07c263a1f14cd80985704d79bf6e1151","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"type_of_change":"1","version":"0.39"}],"id":{"product":"e528a2af212b4bb09bfd3cb54b985653","version":"47feacdd5a9d4714863d1ac9be7b0f31"},"installation":{"command":"CP049504.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP044966.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP044966.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-f36d4ef431-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>&nbsp;on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP044966.scexeスクリプトは 'scexe-compat'フォルダーにあります。'firmware-smartarray-f36d4ef431-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./ CP044966.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*'にある<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-f36d4ef431-*'フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong></p>\n\n<p><strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant</u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux (x64) - HPE Apollo 4200 Gen10 Plusバックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0654","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0654","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0652","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0652","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0602","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0602","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0603","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0603","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"028F","subdev":"1100","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c1100","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-10-09T16:19:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial Release</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"<ul>\n\t<li>Modify Product ID&#39;s to &quot;A4200 Gen10P LFF&quot; and &quot;A4200 Gen10P SFF&quot; to distinguish the generation.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"}],"sw_keys":[{"name":"A4200 Gen10P SFF","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"A4200 Gen10P LFF","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG3"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG3"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG3"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K401HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:<br />\n&nbsp; &nbsp; &nbsp;</strong> HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; &nbsp;None</p>\n"}],"files":[{"bytes":"17924722","datemodified":"2021-08-30T06:14:21","file_list":["/CP049275_BUILD_1.data","/CP049275.vmexe","/CP049275.vmexe64","/CP049275.vmfile","/CP049275_VMw.zip","/CP049275.xml","/payload.json","/CP049275_VMw.zip/index.xml","/CP049275_VMw.zip/vendor-index.xml","/CP049275_VMw.zip/metadata.zip","/CP049275_VMw.zip/vib20/CP049275/HPE_bootbank_CP049275_HPG3.1-7.0.0.15843807.vib","/CP049275_VMw.zip/metadata.zip/vendor-index.xml","/CP049275_VMw.zip/metadata.zip/vmware.xml","/CP049275_VMw.zip/metadata.zip/vibs/CP049275--3623784505556664958.xml","/CP049275_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049275_HPG3.1-7.0.0.15843807.xml"],"md5sum":"d7936ebf2a112a03b251503cdb72d87a","name":"CP049275.zip","release":"2021-08-30T06:08:56","revision":"0","sha1sum":"740926c55af74b15731be4c7dcef7304a6827def","size":"17MB","target_guids":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP049275","version":"HPG3.1-7.0.0.15843807"}]}],"id":{"product":"a4fb8dc02faf478a85519ccf77530c6a","version":"ee8fccebdbac467789857df927f96d69"},"installation":{"command":"CP041496.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi -VK000480GWTHA、VK000960GWTHB、VK001920GWTHCおよびVK003840GWTHDドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWTHD","target_guid":"562340a5-304b-3330-3834-304757544844","type":"sata"},{"id":"VK001920GWTHC","target_guid":"562340a5-304b-3130-3932-304757544843","type":"sata"},{"id":"VK000960GWTHB","target_guid":"562340a5-304b-3030-3936-304757544842","type":"sata"},{"id":"VK000480GWTHA","target_guid":"562340a5-304b-3030-3438-304757544841","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-13T14:17:32","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This maintenance FW release addresses a rare corner case COMRESET issue at warm boot, and to address an early EOL behavior under certain use cases.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK001920GWTHC","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK003840GWTHD","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000480GWTHA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWTHB","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Emulex 10/20Gb Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Windows Server 2016用のHPE Emulex 10/20GbサーバーアダプターのiSCSIドライバー を含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"907296","datemodified":"2020-06-12T06:47:06","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp044561.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"d7398cbac6a655eb182f2b86ba3d8494","name":"cp044561.exe","release":"2020-06-12T06:33:15","revision":"0","sha1sum":"93c0e7dbdda6b4f84f1fca21bb803d28b49d12df","size":"886KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"70f19ffffee546149605e6df93bd9de3","version":"0ce26dd3cd4744ca9f29d5a742fa7ceb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE iSCSI Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbE iSCSIドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c220a","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c8144","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-12T06:00:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p style=\"text-align:left\">This product now supports the following network adapters:</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWFVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"T14SEhD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a57465643","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: EG001800JWFVC"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp;&nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4892540","datemodified":"2021-07-23T08:32:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/CP048066.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/T14SEhD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-693b9a2853-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048066.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048066.scexe"],"md5sum":"b5205e45ca0d9e3032c565d23c5289d7","name":"firmware-hdd-693b9a2853-HPD4-2.1.x86_64.rpm","release":"2021-07-23T08:20:04","revision":"0","sha1sum":"03639e5da2957c3e9839c4830c2042e2f264aaed","size":"4MB","target_guids":["452340a5-3047-3130-3830-304a57465643"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"4dae182fcdec4e4aa31d1ea079120a60","version":"afadc2f4e7af45849d4c2127ad7df913"},"installation":{"command":"CP040349.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"https://www.hp.com/swpublishing/MTX-357c87ee9b054ad7a631d9eaba\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWFVC Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - EG001800JWFVCドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EG001800JWFVC","target_guid":"452340a5-3047-3130-3830-304a57465643","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-21T11:48:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>A low-probability, high severity corner case of sustained outer-diameter activity with emergency power off when heads are at the outer diameter prevented heads from parking/latching properly on a few drives in the field.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG001800JWFVC","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.02"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.02"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R 10GBASE-T Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E15908148","Version":"7.19.02"},{"DeviceName":"HPE StoreFabric CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1931","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.02"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.02"},{"DeviceName":"HP NPAR CN1100R Dual Port Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1931","Version":"7.19.02"},{"DeviceName":"HPE NPAR 10Gb DP CN1100R-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.02.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE15908148","Version":"7.19.02"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE ProLiant QLogic NX2 Gigabit Ethernet NICs Boot code (MFW), PXE, UEFI, iSCSI, FCoE, CCM and L2 code running under Linux x86_64 platform."},{"lang":"ja","x_late":"このパッケージには、Linux x86_64プラットフォームで動作するHPE ProLiant QLogic NX2 Gigabit Ethernet NICブートコード、MFW、PXE、UEFI、iSCSI、FCoE、CCMおよびL2コードをアップグレードするための、ユーティリティおよびバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains combo image v7.19.02&nbsp;with the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"2\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>NIC</strong></td>\n\t\t\t<td><strong>Boot Code Version</strong></td>\n\t\t\t<td><strong>PXE Version</strong></td>\n\t\t\t<td><strong>UEFI Version</strong></td>\n\t\t\t<td><strong>iSCSI Version</strong></td>\n\t\t\t<td><strong>FCoE Version</strong></td>\n\t\t\t<td><strong>CCM Version</strong></td>\n\t\t\t<td><strong>L2 Version</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HP Ethernet 10Gb 2-port 530SFP+ Adapter<br />\n\t\t\tHP Ethernet 10Gb 2-port 530T Adapter</td>\n\t\t\t<td>7.16.05</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.2</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>n/a</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>\n\t\t\t<p>HP Ethernet 10Gb 2-port 533FLR-T Adapter<br />\n\t\t\tHP FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter<br />\n\t\t\tHPE FlexFabric 10Gb 4-port 536FLR-T Adapter<br />\n\t\t\tHP StoreFabric CN1100R Dual Port Converged Network Adapter<br />\n\t\t\tHPE StoreFabric CN1100R-T Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td>7.16.05</td>\n\t\t\t<td>7.14.13</td>\n\t\t\t<td>8.9.2</td>\n\t\t\t<td>7.14.0</td>\n\t\t\t<td>7.14.3</td>\n\t\t\t<td>7.14.4</td>\n\t\t\t<td>7.12.25</td>\n\t\t</tr>\n\t</tbody>\n</table>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"3271767","datemodified":"2021-12-21T08:17:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/CP050209.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/CP050209.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/nic_fw/hp_mbi_7.19.02.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.30.2-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050209.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050209.scexe"],"md5sum":"078b32b70447a989491dc447a80e84fa","name":"firmware-nic-qlogic-nx2-2.30.2-1.1.x86_64.rpm","release":"2021-12-21T08:11:15","revision":"0","sha1sum":"be3541b9d756b7d57f85d2b5dcd602d5a8f1b19e","size":"3MB","target_guids":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-168E15908148","a6b1a447-382a-5a4f-14E4-168E103C1931","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930","a6b1a447-382a-5a4f-14E4-16AE103C1931","a6b1a447-382a-5a4f-14E4-16AE15908148"],"type_of_change":"1","version":"2.30.2"}],"id":{"product":"5f7dae044b3b4d97823b1cfc69305837","version":"a1fe690adf3f4e7793610000eb1457bb"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><em><strong>Steps to update the adapter firmware using the rpm pacakge:</strong></em></p>\n\n<ul>\n\t<li>Install the firmware rpm package:<br />\n\t<em>&gt; rpm -ivh &lt;rpm_filename&gt;.rpm </em></li>\n\t<li>Check where the files are extracted:<br />\n\t<em>&gt; rpm -qlp &lt;rpm_filename&gt;.rpm</em></li>\n\t<li>Using the output from the previous step determine the location of hpsetup file, change to that directory and run &#39;<em>./hpsetup</em>&#39; to update the firmware.</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<ul>\n\t<li>Further information&nbsp;is available in CPxxxxxx.txt file.The results of the firmware upgrade are saved&nbsp;in CPxxxxxx.log at &quot;/var/cpq/.&quot;</li>\n\t<li>Network connectivity may stop during the firmware upgrade process and may need to be restarted after completion.</li>\n\t<li>When update firmware, refer to Revision History and update it to the version as stepping up or down the ladder until the version needed.&nbsp;</li>\n\t<li>Installing the&nbsp;firmware rpm package (rpm -ivh)&nbsp;does not update the adapter firmware, it merely extracts the contents of the rpm package to the local system. Updating the adapter firmware requires following the steps outlined above.</li>\n</ul>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Linux x86_64 的 HPE QLogic NX2 線上韌體升級公用程式"},{"lang":"en","x_late":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64"},{"lang":"ko","x_late":"Linux x86_64용 HPE QLogic NX2 온라인 펌웨어 업그레이드 유틸리티"},{"lang":"cn","x_late":"适用于 Linux x86_64 的 HPE QLogic NX2 在线固件升级实用程序"},{"lang":"ja","x_late":"HPE QLogic NX2オンラインファームウェアアップグレードユーティリティ for Linux x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"168E","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c339d","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c18d3","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1930","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c193a","type":"pci","ven":"14E4"},{"dev":"16A1","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a1159000ec","type":"pci","ven":"1077"},{"dev":"16A4","subdev":"00EC","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1077-16a4159000ec","type":"pci","ven":"1077"},{"dev":"168E","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-168e15908148","type":"pci","ven":"14E4"},{"dev":"168E","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-168e103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"339D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c339d","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"18D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c18d3","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"193A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c193a","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1930","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1930","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"1931","subven":"103C","target_guid":"a6b1a447-382a-5a4f-14e4-16ae103c1931","type":"pci","ven":"14E4"},{"dev":"16AE","subdev":"8148","subven":"1590","target_guid":"a6b1a447-382a-5a4f-14e4-16ae15908148","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T07:37:12","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Red Hat Enterprise Linux 8 update 4 and SUSE Linux Enterprise Server 15 Service Pack 3</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>TBD</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U40","value":"HPE Apollo 4530 Gen10"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"QLOGIC_NX2","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPD6"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SSKYBT512ED6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EG001800JWJNR and EG002400JWJNT"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EG001800JWJNRおよびEG002400JWJNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR and EG002400JWJNT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"18695036","datemodified":"2021-08-30T04:28:31","file_list":["/CP048254_BUILD_2.data","/CP048254.vmexe","/CP048254.vmexe64","/CP048254.vmfile","/CP048254_VMw.zip","/CP048254.xml","/payload.json","/CP048254_VMw.zip/index.xml","/CP048254_VMw.zip/vendor-index.xml","/CP048254_VMw.zip/metadata.zip","/CP048254_VMw.zip/vib20/CP048254/HPE_bootbank_CP048254_HPD6.2-7.0.0.15843807.vib","/CP048254_VMw.zip/metadata.zip/vendor-index.xml","/CP048254_VMw.zip/metadata.zip/vmware.xml","/CP048254_VMw.zip/metadata.zip/vibs/CP048254-1748087930984269899.xml","/CP048254_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048254_HPD6.2-7.0.0.15843807.xml"],"md5sum":"56ed0b6c39c347d6ea03cd70f50e23ba","name":"CP048254.zip","release":"2021-08-30T04:23:07","revision":"0","sha1sum":"975b4b9658f855f1692d20727ff1dc069c369261","size":"17MB","target_guids":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048254","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"58058fc7c39a49caa2844dbe139ab3f9","version":"10b023cb6a744ca7871db201b4c5029b"},"installation":{"command":"CP042785.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - EG001800JWJNR and EG002400JWJNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - EG001800JWJNRおよびEG002400JWJNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"EG001800JWJNR","target_guid":"452340a5-3047-3130-3830-304a574a4e52","type":"sas"},{"id":"EG002400JWJNT","target_guid":"452340a5-3047-3230-3430-304a574a4e54","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-02T08:42:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EG002400JWJNT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EG001800JWJNR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v2.62 (03/08/2022)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U34_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Windows","Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM), this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM) と共に使用する場合、このコンポーネントは、ユーザーが中央からリモートサーバーのファームウェアをアップデートすることを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11714280","datemodified":"2022-03-08T12:55:32","file_list":["cp051178.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_2.62_03_08_2022.signed.flash"],"md5sum":"983b91bf34fa8f116617b10dd657b796","name":"cp051178.exe","release":"2022-03-09T00:00:00","revision":"1","sha1sum":"b8d733295eef5fdc79b212b90c8e84a1ce6badfe","size":"11MB","target_guids":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"18633ffffaeb4435bcda138419e66c7a","version":"0ba2b46892c04b17818fdd0479d9866a"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system if you would like the update to take effect immediately.</p>\n\n<p><br />\n&nbsp;</p>\n\n<p><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</p>\n\n<p><br />\n </p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34)サーバー "}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-24T09:36:56","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"U34","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"tw","x_late":"本產品包含 Red Hat Enterprise Linux 7 x86_64 下執行的 HPE Intel ixgbe 乙太網路 NIC 之 SRIOV 虛擬功能驅動程式。"},{"lang":"en","x_late":"This product contains the SRIOV virtual function drivers for the HPE Intel ixgbe Ethernet NICs running under Red Hat Enterprise Linux 7 x86_64."},{"lang":"ko","x_late":"이 제품에는 Red Hat Enterprise Linux 7 x86_64에서 실행되는 HPE Intel ixgbe 이더넷 NIC용 SRIOV 가상 기능 드라이버가 포함되어 있습니다."},{"lang":"cn","x_late":"本产品包含适用于在 Red Hat Enterprise Linux 7 x86_64 下方运行的 HPE Intel ixgbe 以太网网卡的 SRIOV 虚拟功能驱动程序。"},{"lang":"ja","x_late":"この製品には、Red Hat Enterprise Linux 7 x86_64で動作するHPE Intel ixgbe Ethernet NIC用のSRIOV仮想機能ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"62432","datemodified":"2021-11-09T06:13:48","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1160.el7.x86_64","./lib/modules/3.10.0-1160.el7.x86_64/extra","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1160.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/95c341ea3efe0a82c3a09b422f83fe90b0adfc","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"fe2265357e2a9b5ce71dc22c24069344","name":"kmod-hp-ixgbevf-4.13.3-1.rhel7u9.x86_64.rpm","release":"2021-11-09T06:07:18","revision":"0","sha1sum":"b597b4b407fef85331d3d274ebefe999107753b7","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.13.3-1"},{"bytes":"62436","datemodified":"2021-11-09T06:15:09","file_list":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/3.10.0-1127.el7.x86_64","./lib/modules/3.10.0-1127.el7.x86_64/extra","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf","./lib/modules/3.10.0-1127.el7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/c3fc2e5f5c3656f69525dc298560eff873bf0e","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"md5sum":"c0322ea1b6d3c02b2c74ec9652de1d13","name":"kmod-hp-ixgbevf-4.13.3-1.rhel7u8.x86_64.rpm","release":"2021-11-09T06:07:18","revision":"0","sha1sum":"25480ba2d495b590dd3ff03a96235d06f90e1b5c","size":"60KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"type_of_change":"0","version":"4.13.3-1"}],"id":{"product":"288e2f6737ed4857873f59d466b41139","version":"f496a6fd92b648e69c845e5444ff5e00"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download README for installation notes.</p>\n"},{"lang":"ja","x_late":"<p>インストールのノートについてREADMEをダウンロードします。</p>\n"}],"manufacturer_name":[],"name":[{"lang":"tw","x_late":"適用於 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驅動程式"},{"lang":"en","x_late":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 7 x86_64"},{"lang":"ko","x_late":"Red Hat Enterprise Linux 7 x86_64용 HPE Intel ixgbevf 드라이버"},{"lang":"cn","x_late":"适用于 Red Hat Enterprise Linux 7 x86_64 的 HPE Intel ixgbevf 驱动程序"},{"lang":"ja","x_late":"HPE Intel ixgbevfドライバー for Red Hat Enterprise Linux 7 x86_64"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"152E","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1530","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>This product now supports Red Hat Enterprise Linux 7 update 9</li>\n\t<li>This product enhances reliability via adding support for new mailbox communication between PF(Physical Function) and VF(Virtual Function) and remove its potential flaws that may lead to the undefined or faulty behavior</li>\n\t<li>This product enhances compatibility where new mailbox api implementation is alo compatible with old drivers</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product addresses an issue where potential memory leak</li>\n\t<li>This product addresses an issue where eXpress Data Path(XDP) frame size calculations.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"U24","value":"HPE ProLiant XL260a Gen9 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U12","value":"HPE ProLiant XL230b Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U18","value":"HPE ProLiant XL730f Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U18","value":"HP ProLiant XL740f Gen9 Server"},{"key":"U18","value":"HP ProLiant XL750f Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"},{"name":"kmod-hp-ixgbevf","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This RPM contains the HPE Tested and Approved Linux based Mellanox RoCE (RDMA over Converged Ethernet) driver for supported HPE Mellanox adapter cards."},{"lang":"ja","x_late":"このRPMには、サポートされているHPE Mellanoxアダプターカード用のHPEによるテストと承認済みのLinuxベースMellanox RoCE (RDMA over Converged Ethernet)ドライバーが含まれます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1931979","datemodified":"2021-11-02T21:05:48","file_list":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/connectx.conf","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/infiniband/vf-net-link-name.sh","./etc/init.d/openibd","./etc/libibverbs.d/mlx4.driver","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/security/limits.d/30-libvma-limits.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./etc/udev/rules.d/82-net-setup-link.rules","./etc/udev/rules.d/90-ib.rules","./sbin/connectx_port_config","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/hca_self_test.ofed","./usr/bin/ibdev2netdev","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_get_vfs.pl","./usr/bin/mlnx_perf","./usr/bin/mlnx_qcn","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/tc_wrap.py","./usr/lib/python2.7/site-packages/dcbnetlink.py","./usr/lib/python2.7/site-packages/dcbnetlink.pyc","./usr/lib/python2.7/site-packages/dcbnetlink.pyo","./usr/lib/python2.7/site-packages/genetlink.py","./usr/lib/python2.7/site-packages/genetlink.pyc","./usr/lib/python2.7/site-packages/genetlink.pyo","./usr/lib/python2.7/site-packages/netlink.py","./usr/lib/python2.7/site-packages/netlink.pyc","./usr/lib/python2.7/site-packages/netlink.pyo","./usr/lib/python2.7/site-packages/ofed_le_utils-1.0.3-py2.7.egg-info","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/vma.service","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.2.0","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.0.0","./usr/lib64/libmlx4-rdmav2.so","./usr/lib64/libmlx5-rdmav2.so","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.0.0","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.0.0","./usr/lib64/libvma-debug.so","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.0.2","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/odp_stat.sh","./usr/sbin/ofed_uninstall.sh","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vma","./usr/sbin/vmad","./usr/share/doc/packages/ib2ib","./usr/share/doc/packages/ib2ib/README","./usr/share/doc/packages/libibumad","./usr/share/doc/packages/libibumad/AUTHORS","./usr/share/doc/packages/libibumad/COPYING","./usr/share/doc/packages/libibumad/ChangeLog","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/AUTHORS","./usr/share/doc/packages/libibverbs/COPYING","./usr/share/doc/packages/libibverbs/ChangeLog","./usr/share/doc/packages/libibverbs/README","./usr/share/doc/packages/libmlx4","./usr/share/doc/packages/libmlx4/AUTHORS","./usr/share/doc/packages/libmlx4/COPYING","./usr/share/doc/packages/libmlx4/README","./usr/share/doc/packages/libmlx5","./usr/share/doc/packages/libmlx5/AUTHORS","./usr/share/doc/packages/libmlx5/COPYING","./usr/share/doc/packages/libmlx5/README","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/AUTHORS","./usr/share/doc/packages/librdmacm/COPYING","./usr/share/doc/packages/librdmacm/README","./usr/share/doc/packages/libvma-9.0.2/README.txt","./usr/share/doc/packages/libvma-9.0.2/VMA_VERSION","./usr/share/doc/packages/libvma-9.0.2/journal.txt","./usr/share/man/man3/umad_addr_dump.3.gz","./usr/share/man/man3/umad_alloc.3.gz","./usr/share/man/man3/umad_attribute_str.3.gz","./usr/share/man/man3/umad_class_str.3.gz","./usr/share/man/man3/umad_close_port.3.gz","./usr/share/man/man3/umad_debug.3.gz","./usr/share/man/man3/umad_done.3.gz","./usr/share/man/man3/umad_dump.3.gz","./usr/share/man/man3/umad_free.3.gz","./usr/share/man/man3/umad_free_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca.3.gz","./usr/share/man/man3/umad_get_ca_namelist.3.gz","./usr/share/man/man3/umad_get_ca_portguids.3.gz","./usr/share/man/man3/umad_get_cas_names.3.gz","./usr/share/man/man3/umad_get_fd.3.gz","./usr/share/man/man3/umad_get_issm_path.3.gz","./usr/share/man/man3/umad_get_mad.3.gz","./usr/share/man/man3/umad_get_mad_addr.3.gz","./usr/share/man/man3/umad_get_pkey.3.gz","./usr/share/man/man3/umad_get_port.3.gz","./usr/share/man/man3/umad_init.3.gz","./usr/share/man/man3/umad_mad_status_str.3.gz","./usr/share/man/man3/umad_method_str.3.gz","./usr/share/man/man3/umad_open_port.3.gz","./usr/share/man/man3/umad_poll.3.gz","./usr/share/man/man3/umad_recv.3.gz","./usr/share/man/man3/umad_register.3.gz","./usr/share/man/man3/umad_register2.3.gz","./usr/share/man/man3/umad_register_oui.3.gz","./usr/share/man/man3/umad_release_ca.3.gz","./usr/share/man/man3/umad_release_port.3.gz","./usr/share/man/man3/umad_send.3.gz","./usr/share/man/man3/umad_set_addr.3.gz","./usr/share/man/man3/umad_set_addr_net.3.gz","./usr/share/man/man3/umad_set_grh.3.gz","./usr/share/man/man3/umad_set_grh_net.3.gz","./usr/share/man/man3/umad_set_pkey.3.gz","./usr/share/man/man3/umad_size.3.gz","./usr/share/man/man3/umad_status.3.gz","./usr/share/man/man3/umad_unregister.3.gz","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"md5sum":"2aee23a34a46ad84485b687ed39c60ac","name":"mlnx-ofa_kernel-4.9-OFED.4.9.4.0.8.1.sles12sp5.x86_64.rpm","release":"2021-11-02T19:55:05","revision":"0","sha1sum":"647d57df60573c56286b800fdd2e90c0d73dd8f8","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"},{"bytes":"1945316","datemodified":"2021-11-02T21:07:12","file_list":["./lib/modules/4.12.14-120-default","./lib/modules/4.12.14-120-default/updates","./lib/modules/4.12.14-120-default/updates/compat","./lib/modules/4.12.14-120-default/updates/compat/mlx_compat.ko","./lib/modules/4.12.14-120-default/updates/drivers","./lib/modules/4.12.14-120-default/updates/drivers/infiniband","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb3/iw_cxgb3.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/i40iw/i40iw.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/nes/iw_nes.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/4.12.14-120-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/4.12.14-120-default/updates/drivers/net","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx4/mlx4_en.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlx5/fpga/mlx5_fpga_tools.ko","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/4.12.14-120-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host","./lib/modules/4.12.14-120-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target","./lib/modules/4.12.14-120-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/4.12.14-120-default/updates/net","./lib/modules/4.12.14-120-default/updates/net/9p","./lib/modules/4.12.14-120-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/rds","./lib/modules/4.12.14-120-default/updates/net/rds/rds_rdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/4.12.14-120-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"md5sum":"f821c2a3e32a3ee1044d989244664920","name":"mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.4.0.8.1.sles12sp5.x86_64.rpm","release":"2021-11-02T19:55:05","revision":"0","sha1sum":"6fc53e4fdc6bd25181f4bac84a3cb0eb752aa994","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"type_of_change":"1","version":"4.9-4.0.8.1"}],"id":{"product":"38f8dc6c0e3046598e2c4afc7a94419e","version":"281e2cec49ff4cb084cbfb6b783b838f"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"name":"Linux","value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.4","description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Login as root, download the RPMs to a directory on your hard drive and change to that directory.<br />\n<br />\n<strong>Note</strong>: Irrespective of the kernel version or type used, the &quot;mlnx-ofa_kernel-4.9&quot; RPM must be installed to enable the user space functionality for RoCE. The RoCE user space library RPM (mlnx-ofa_kernel) may conflict with the OpenMPI RPMs included with the OS distribution.This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of &quot;mlnx-ofa_kernel&quot;. If already installed, uninstall any OpenMPI distribution RPMs before installing HPE Mellanox RoCE driver packages.<br />\n<br />\nTo install or upgrade the driver:<br />\nIf using 4.12.14-120-default kernel or any future errata:<br />\n<br />\n<strong># rpm -Uvh&nbsp;mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm&nbsp;mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nSetup is now complete. Reboot your computer for the driver to take effect.</p>\n"},{"lang":"ja","x_late":"<p>rootとしてログインし、rpmをご使用のハードディスク上のディレクトリにダウンロードし、そのディレクトリに移動します。<br />\n<br />\n<strong>注記</strong>：RoCEのユーザースペース機能を有効にするために、使用されているカーネルバージョンやタイプにかかわらず、\"mlnx-ofa_kernel-4.9\" RPMをインストールする必要があります。RoCEのユーザースペースライブラリであるRPM（mlnx-ofa_kernel）はOS配布に含まれるOpenMPI RPMと競合することがあります。これは既知の挙動です。Linux分布からのOpenMPI RPMは\"mlnx-ofa_kernel\"のインストレーションの前にはターゲットのノードにインストールされないことに注意が必要です。もし既にインストールされていれば、 HPE Mellanox RoCEのドライバーパッケージをインストールする前にすべてのOpenMPI配布のRPMをアンインストールしてください。<br />\n<br />\nドライバーをインストールまたはアップグレードするには次のようにします。<br />\n4.12.14-120-defaultカーネルまたは任意の将来のerrataを使用する場合：<br />\n<br />\n<strong># rpm -Uvh mlnx-ofa_kernel-4.9-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm mlnx-ofa_kernel-kmp-default-4.9_k4.12.14_120-OFED.4.9.3.1.6.1.sles12sp5.x86_64.rpm</strong><br />\n<br />\nセットアップは完了しました。ドライバーを有効にするにはコンピューターを再起動します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett-Packard Development Company, L.P."}],"name":[{"lang":"en","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) Driver for SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"},{"lang":"ja","x_late":"HPE Mellanox RoCE (RDMA over Converged Ethernet) ドライバーfor SUSE LINUX Enterprise Server 12 SP5 (AMD64/EM64T)"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"1007","subdev":"8020","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c8020","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"801F","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c801f","type":"pci","ven":"15B3"},{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-02T08:49:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>The following changes and new features are added in version 4.9:</strong></p>\n\n<ul>\n\t<li><strong>For ConnectX-5 Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Option to dump configuration space via the devlink tool in order to improve debug capabilities.</li>\n\t<li>The conventional TX descriptor (WQE or Work Queue Element) describes a single packet for transmission. Added driver support for the HW feature of multi-packet TX WQEs in XDP transmit flows. With this, the HW becomes capable of working with a new and improved WQE layout that describes several packets. In effect, this feature saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>GENEVE encapsulation/decapsulation rules offload.</li>\n\t<li>Driver support for the hardware feature of multi-packet Tx to work with a new and improved WQE layout that describes several packets instead of a single packet for XDP transmission flows. This saves PCI bandwidth and transactions, and improves transmit packet rate.</li>\n\t<li>Updating CT (Connection Tracking) rules using the software steering mechanism.</li>\n\t<li>Updating remote mirroring rules using the software steering mechanism.<br />\n\t&nbsp;</li>\n\t<li><strong>For ConnectX-4&nbsp;Adapters and above</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Exposed rx_prio[p]_discards discard counters per priority that count the number of received packets dropped due to lack of buffers on the physical port.</li>\n\t<li>Reporting TSO and CSUM offload capabilities for MPLS tagged traffic and, allowed the kernel stack to use these offloads.</li>\n\t<li>mlx5e Max Combined Channels Increased the driver&rsquo;s maximal combined channels value from 64 to 128 (however, note that OOB value will not cross 64). 128 is the upper bound. Lower maximal value can be seen on the host, depending on the number of cores and MSIX&#39;s configured by the firmware.</li>\n\t<li>Added the following RoCE accelerator counters:\n\t<ul>\n\t\t<li>roce_adp_retrans - counts the number of adaptive retransmissions for RoCE traffic.</li>\n\t\t<li>roce_adp_retrans_to - counts the number of times RoCE traffic reached timeout due to adaptive retransmission.</li>\n\t\t<li>roce_slow_restart - counts the number of times RoCE slow restart was used.</li>\n\t\t<li>roce_slow_restart_cnps - counts the number of times RoCE slow restart generated CNP packets roce_slow_restart_trans - counts the number of times RoCE slow restart changed state to slow restart.</li>\n\t</ul>\n\t</li>\n\t<li>User to register memory regions with a relaxed ordering access flag through experimental verbs. This can enhance performance, depending on architecture and scenario.<br />\n\t&nbsp;</li>\n\t<li><strong>For&nbsp;All HCA&#39;s</strong></li>\n</ul>\n\n<p><strong>Added support for the following features:</strong></p>\n\n<ul>\n\t<li>Output ibdev2netdev tool output was changed such that the bonding device now points at the bond instead of the slave interface.</li>\n\t<li>Monitoring and recovering from errors that occur on the RX queue, such as cookie errors and timeout.</li>\n\t<li>Improved GSO (Generic Segmentation Offload) workload performance by decreasing doorbells usage to the minimum required.</li>\n\t<li>TX CQE (Completion Queue Element) compression. Saves on outgoing PCIe bandwidth by compressing CQEs together. Disabled by default. Configurable via private flags of ethtool.</li>\n\t<li>Firmware Versions Query via Devlink :Added the option to query for running and stored firmware versions using the devlink tool.</li>\n\t<li>Firmware Flash Update via Devlink :Added the option to update the firmware image in the flash using the devlink tool. Usage: devlink dev flash file .mfa2 For further information on how to perform this update, see &quot;Updating Firmware Using ethtool/devlink and .mfa2 File&quot; section in MFT User Manual.</li>\n\t<li>WQE (Work Queue Element) dump, triggered by an error on Rx/Tx reporters. In addition, some dumps (not triggered by an error) can be retrieved by the user via devlink health reporters.</li>\n\t<li>GENEVE tunneled hardware offloads of TSO, CSUM and RSS.</li>\n\t<li>TCP segmentation and checksum offload support for MPLS-tagged traffic.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 4.9:</strong></p>\n\n<ul>\n\t<li>IOMMU allocation failures occurred when the device was under massive load.</li>\n\t<li>&quot;ibv_devinfo -v&quot; command did not print some of the MEM_WINDOW capabilities, even though they were supported.<br />\n\t&nbsp;</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"I36","value":"HPE ProLiant WS460c Gen9 Graphics Server Blade"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"P89","value":"HP ProLiant DL388 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel","sw_key_expectedpath":"software:rpm"},{"name":"mlnx-ofa_kernel-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"12.8.528.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.528.21"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"5967042","datemodified":"2022-01-21T09:03:10","file_list":["/CP049955_BUILD_6.data","/CP049955.vmexe","/CP049955.vmexe64","/CP049955.vmfile","/CP049955_VMw.zip","/CP049955.xml","/payload.json","/CP049955_VMw.zip/index.xml","/CP049955_VMw.zip/vendor-index.xml","/CP049955_VMw.zip/metadata.zip","/CP049955_VMw.zip/vib20/CP049955/HPE_bootbank_CP049955_2022.03.01.6-7.0.0.15843807.vib","/CP049955_VMw.zip/metadata.zip/vendor-index.xml","/CP049955_VMw.zip/metadata.zip/vmware.xml","/CP049955_VMw.zip/metadata.zip/vibs/CP049955--2175873702055695684.xml","/CP049955_VMw.zip/metadata.zip/bulletins/Smart-Component-CP049955_2022.03.01.6-7.0.0.15843807.xml"],"md5sum":"593ed389c6600e823cbfca10f8bbbfcb","name":"CP049955.zip","release":"2022-01-21T09:00:04","revision":"0","sha1sum":"43f693e58123c9a1e8a7e4ae50c1125bc7eaedc2","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2022.03.01","vib_list":[{"name":"CP049955","version":"2022.03.01.6-7.0.0.15843807"}]}],"id":{"product":"40aca5b1425544eabf3dc630ea9b775f","version":"01a34a2ebbb147afbfc6834607f6824d"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください：<br />\nオフライン：</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiantオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが用いられます</li>\n</ul>\n\n<p><strong>Remote Online、コンポーネントがSUMでサポートされているが、まだSPPの一部ではない場合：</strong></p>\n\n<ul>\n\t<li>適切なService Pack for ProLiantをダウンロードします</li>\n\t<li>Service Pack for ProLiantにコンポーネントを追加します</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でService Pack for ProLiantをマウントします</li>\n\t<li>Windows用のlaunch_sum.batまたはLinux用のlaunch_sum.shを介してSmart Update Managerを実行します</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します</li>\n\t<li>アップデートするESXiホストのIPまたはDNSアドレスを入力するか（ESXiホストがGen9サーバーの場合）、ESXiホストのiLOのIPまたはDNSアドレスを入力します（サーバーがGen10以上の場合）</li>\n\t<li>Gen9/Gen10以上に基づいてESXiホスト/iLO認証情報（rootまたは管理者のユーザー名およびパスワード）を入力します</li>\n\t<li>Smart Update Manager 6.0以降の場合は、ノードインベントリページで追加されたコンポーネントおよびService Pack for ProLiantベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n\t<li>詳しくは、<a href=\"http://www.hpe.com/jp/servers/spp_dl\">www.hpe.com/jp/servers/spp_dl</a>のService Pack for ProLiantドキュメントを参照してください</li>\n</ul>\n\n<p> </p>\n\n<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします。</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p> </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネント（CPxxxxxx.zip）を一時ディレクトリに置きます。</li>\n\t<li>同じディレクトリからSmartコンポーネントをunzipします。\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>Smartコンポーネントには、ファームウェアのインストールを実行するためにインストールする必要のあるVIBで構成されたCPxxxxx_VMw.zipが含まれています</li>\n\t<li>CPxxxxxx_VMw.zipファイルが実行可能であることを確認します。次のコマンドを実行します：\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>スタンドアロンのインストールを行うために、次のコマンドを実行します：</li>\n\t<li>esxcli software vib install -d /<path_of_CPxxxxxx_VMw.zip>/CPxxxxxx_VMw.zip</li>\n\t<li>インストールが完了したら、ディレクトリを/opt/Smart_Component/<CPxxxxxx>に変更します。次のコマンドを実行します：\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/<CPxxxxxx></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアのスタンドアロンのインストールを行うために、次のコマンドを実行します：\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Smartコンポーネントの指示に従います</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n\t<li>必要に応じてシステムを再起動し、ファームウェアのアップデートを有効にします。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  7.0"},{"lang":"ja","x_late":"HPEファームウェアフラッシュfor Emulexファイバーチャネルホストバスアダプターfor VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"PMCI PLDM FW Update for MR216i-p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"HPE_MR216i-p_Gen10P_52.16.3-3913.ilo","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"SysPowerON":false,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.16.3-3913"}]},"PackageFormat":"FWPKG-v2","Type":"Firmware","UpdatableBy":["Bmc"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"Universal Firmware PLDM file for the HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR216i-p Gen10 Plusトライモードコントローラー用のユニバーサルファームウェアPLDMファイル"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"7491284","datemodified":"2021-09-08T14:48:54","file_list":["HPE_MR216i-p_Gen10P_52.16.3-3913.ilo","HPE_MR216i-p_Gen10P_52.16.3-3913.xml","payload.json"],"md5sum":"2f62ee1f9650e1c0d314457f655c953d","name":"HPE_MR216i-p_Gen10P_52.16.3-3913.fwpkg","release":"2021-09-08T14:45:27","revision":"0","sha1sum":"1ab50b212992f520aaa23430a2dec05a7244b998","size":"7MB","target_guids":["a6b1a447-382a-5a4f-1000-10e21590032b"],"type_of_change":"1","version":"52.16.3-3913"}],"id":{"product":"87a7eb56c25b4c4c98ceb5ea24664524","version":"3f59505062c64672928677d1ee1c3448"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p><br />\nThis firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using&nbsp;SUM, which is found on the&nbsp;<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong>&nbsp;(SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the&nbsp;<strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a>を参照してください。</p>\n\n<p>ローカルホストOSの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例:<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p><br />\nこのファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR216i-p Gen10 Plus Tri Mode Controller"},{"lang":"ja","x_late":"HPE MR216i-p Gen10 Plusトライモードコントローラー"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-08T14:12:31","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Initial Build</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial Release</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"032B1590","sw_key_expectedpath":"firmware"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800374","languages":[{"lang":"fr","x_late":"Logiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Software - Storage Fibre Channel"},{"lang":"cn","x_late":"软件 - 存储光纤通道"},{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Software - Glasfaserspeicher"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Software - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Software - Canal de fibra de almacenamiento"}]},{"key":"7800374","languages":[{"lang":"tw","x_late":"軟體 ─ 儲存裝置光纖通道 HBA"},{"lang":"en","x_late":"Software - Storage Fibre Channel HBA"},{"lang":"ko","x_late":"소프트웨어 - 스토리지 파이버 채널 HBA"},{"lang":"ja","x_late":"ソフトウェア - ストレージ ファイバ チャネルHBA"},{"lang":"cn","x_late":"软件 - 存储光纤通道 HBA"}]}],"description":[{"lang":"tw","x_late":"此套件包含 Emulex 光纖通道主機匯流排配接卡的 Linux 作業系統上提供對 Smart SAN 的支援套件。"},{"lang":"en","x_late":"This package contains the kit to provide support for Smart SAN on Emulex fibre channel host bus adapters on Linux operating systems."},{"lang":"ko","x_late":"이 패키지에는 Linux 운영 체제에서 Emulex 파이버 채널 호스트 버스 어댑터에 대 한 스마트 SAN에 대 한 지원을 제공 하는 키트에 포함 됩니다."},{"lang":"cn","x_late":"该软件包提供的套件，在 Linux 操作系统上的 Emulex 光纤通道主机总线适配器上提供的 Smart SAN 的支持。"},{"lang":"ja","x_late":"このパッケージは、LinuxオペレーティングシステムでEmulexファイバーチャンネルホストバスアダプター上のSmart SANのサポートを提供するためのキットを含みます。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"20987","datemodified":"2021-12-21T06:43:08","file_list":["./opt/hpe/elx_smartsan/SmartSAN.sh","./opt/hpe/elx_smartsan/elx_ss_enablement","./opt/hpe/elx_smartsan/readme.txt","./usr/share/smartupdate/hpe-emulex-smartsan-enablement-kit/component.xml"],"md5sum":"737cfbe8e4804cdcd840d9a61a70a506","name":"hpe-emulex-smartsan-enablement-kit-1.0.0.0-4.x86_64.rpm","release":"2021-12-21T06:42:30","revision":"0","sha1sum":"2e73adc717ce2ea572ec9079b129b6d1405879c0","size":"20KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec7dd508ef"],"type_of_change":"0","version":"1.0.0.0-4"}],"id":{"product":"63a556e6179b4101ae6472eac493f29b","version":"eaa06cff96c647729e7d2ea0cb1ca938"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>SmartSAN is a 64 bit&nbsp;specific kit.&nbsp;It is recommended that you uninstall any previous kits prior to installation of this component.</p>\n\n<p style=\"margin-left:40px\">To uninstall the Emulex Smart SAN enablement RPM use the following command:</p>\n\n<p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-&lt;version&gt;.noarch.rpm</p>\n\n<p>This is a configurable component.&nbsp; It requires a configuration file in order to enable/disable Smart SAN functionality.&nbsp; If no configuration is performed, the current Smart SAN status is stated and the execution is complete.&nbsp; No further action is taken.</p>\n\n<p>&nbsp;</p>\n\n<p>For detailed information about configurable components, see the&nbsp;<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&amp;docId=a00106063en_us\"><em>Smart Update Manager User Guide </em></a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Component execution outside of HPE Service Pack for Proliant</strong>:</p>\n\n<p style=\"margin-left:40px\">1.&nbsp;Login as the system administrator (root).</p>\n\n<p style=\"margin-left:40px\">2.&nbsp;Download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<p style=\"margin-left:40px\">3.&nbsp;To install, type the following command at the prompt:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; # rpm -ivh hpe-emulex-smartsan-enablement-kit-&lt;version&gt;.x86_64.rpm<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Example: # rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-1.x86_64.rpm</p>\n\n<p style=\"margin-left:40px\">4.&nbsp;When the installation or upgrade is complete, the following message displays:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Installation complete</p>\n\n<p style=\"margin-left:40px\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>SmartSANは64ビット固有のキットです。 このコンポーネントをインストールする前に以前のキットをアンインストールすることをお勧めします。</p>\n\n<p style=\"margin-left:40px\">Emulex Smart SANイネーブルメントRPMをアンインストールするには、次のコマンドを使用します：</p>\n\n<p style=\"margin-left:40px\"># rpm -e hpe-emulex-smartsan-enablement-<version>.noarch.rpm</p>\n\n<p>これは構成可能コンポーネントです。  Smart SAN機能を有効/無効にするための構成ファイルが必要です。  実行される構成がない場合は、現在のSmart SANステータスが提示され、実行が完了します。  それ以上のアクションは行われません。</p>\n\n<p> </p>\n\n<p>構成可能コンポーネントについて詳しくは、<a href=\"https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=a00106063en_us\"><em>Smart Update Managerユーザーガイド</em></a>を参照してください。</p>\n\n<p> </p>\n\n<p><strong>\"HPE Service Pack for ProLiant\"以外でのコンポーネントの実行</strong>：</p>\n\n<p style=\"margin-left:40px\">1.  システム管理者 (root) としてログインします。</p>\n\n<p style=\"margin-left:40px\">2.  RPMをご使用のローカルドライブディレクトリにダウンロードし、そのディレクトリに移動します。</p>\n\n<p style=\"margin-left:40px\">3.  インストールするには、プロンプトで以下のコマンドを入力してください：<br />\n                    # rpm -ivh hpe-emulex-smartsan-enablement-kit-<version>.x86_64.rpm<br />\n                    例：# rpm -ivh hpe-emulex-smartsan-enablement-kit-1.0.0.0-1.x86_64.rpm</p>\n\n<p style=\"margin-left:40px\">4.  インストールまたはアップグレードが完了した場合、以下のメッセージが表示されます：<br />\n                    Installation complete</p>\n\n<p style=\"margin-left:40px\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"tw","x_late":"適用於 Linux 的 SmartSAN SmartSAN 啟用套件"},{"lang":"en","x_late":"HPE Emulex Smart SAN Enablement Kit for Linux"},{"lang":"ko","x_late":"Linux용 Emulex SmartSAN 인에이블먼트 키트"},{"lang":"cn","x_late":"Linux版SmartSAN SmartSAN支持套件"},{"lang":"ja","x_late":"HPE Emulex Smart SAN イネーブルメントキット（Linux）"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:46","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Boscawen 64G</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Added support to SLES15SP3</p>\n\n<p>Updated to version 1.0.0.0-4</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"hpe-emulex-smartsan-enablement-kit","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWCEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757434556","Version":"HPG3"},{"DeviceName":"MK000960GWCFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757434641","Version":"HPG3"},{"DeviceName":"MK001920GWCFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-304757434642","Version":"HPG3"},{"DeviceName":"MK000240GWCEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GS863aG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3234-304757434555","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"2811176","datemodified":"2021-07-25T17:06:36","file_list":["cp048624.xml","cpqsetup.exe","GS863aG3.rel","payload.json","setup.dll"],"md5sum":"db7d327828cfa37d023efa9730016dee","name":"cp048624.exe","release":"2021-07-25T16:59:05","revision":"0","sha1sum":"17ed42d1ff46df8c6ad47e28d2288fcd26121807","size":"2MB","target_guids":["4d2340a5-304b-3030-3438-304757434556","4d2340a5-304b-3030-3936-304757434641","4d2340a5-304b-3130-3932-304757434642","4d2340a5-304b-3030-3234-304757434555"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"707803ff432e4432b9c2ea604ffe836c","version":"dac48784422f4d5b9c8ea5e99c30643d"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000240GWCEU, MK000480GWCEV, MK000960GWCFA and MK001920GWCFB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64)- MK000240GWCEU、MK000480GWCEV、MK000960GWCFAおよびMK001920GWCFBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK001920GWCFB","target_guid":"4d2340a5-304b-3130-3932-304757434642","type":"sata"},{"id":"MK000240GWCEU","target_guid":"4d2340a5-304b-3030-3234-304757434555","type":"sata"},{"id":"MK000480GWCEV","target_guid":"4d2340a5-304b-3030-3438-304757434556","type":"sata"},{"id":"MK000960GWCFA","target_guid":"4d2340a5-304b-3030-3936-304757434641","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T13:12:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK000240GWCEU","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWCFA","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK001920GWCFB","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWCEV","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE VPI (Ethernet and Infiniband mode of operation) ConnectX6 devices on Windows x86_64 platform."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"21622488","datemodified":"2022-02-10T04:44:54","file_list":["cp050422.xml","cpqsetup.exe","fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"md5sum":"addb5e659d3549ef353024e72d06704d","name":"cp050422.exe","release":"2022-02-10T04:43:16","revision":"0","sha1sum":"4c912351b48a614265e9ecc0775f0e299b9105e9","size":"20MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.0.5"}],"id":{"product":"25bee0f636714c0e8bface2301234fec","version":"6ca6c792d66c4ef3ad538e11f75adcc2"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n\n<p>Click the Install button to proceed with the installation.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform"}],"prerequisites":{"required_diskspace":{"size_kb":"27000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T07:06:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21</p>\n\n<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot.&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n<strong>Additional Fixes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>\n\t<li>Improved PortXmitWait IB counter accuracy.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 20.32.1010:</strong></p>\n\n<ul>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li>\n</ul>\n\n<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. If case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit per-host per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n\t<li>Limited the external loopback speed according to the used module&#39;s capabilities.</li>\n\t<li>Modified the Effective BER calculation method. Due to this, the value of the Effective BER will be slightly higher, however the link quality remains the same as prior to this change.</li>\n\t<li>This firmware version includes the following PCIe changes:\n\t<ul>\n\t\t<li>Fixed the ACS Port Number field in DSPs and ACS Egress Control Vector field in DSPs.</li>\n\t\t<li>Added support for VSC on USP of PCIe Switch.</li>\n\t\t<li>Fixed the mapping of Legacy Interrupts in the PCIe Switch.</li>\n\t\t<li>Fixed MRRS &amp; MPS configurations in DSPs.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>System could not create more than 128K QPs.</li>\n\t<li>Incorrect indication of the PCIe link down in the AER registers on PCIe switch upstream port.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The flash frequency on boot was lower than expected (under 50Mhz). The issue was fixed by enabling the firmware to increase it on boot2 to normal frequency.</li>\n\t<li>A race condition between DC QP flush and DC packets that led to stuck slices in the hardware. To avoid such situation, firmware keeps the TCU drop set until QP flush is done.</li>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KWZQR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3130-3932-304b575a5152","Version":"HPK5"},{"DeviceName":"VO003840KWZQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"GP173300HPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304f-3330-3834-304b575a5154","Version":"HPK5"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900357","languages":[{"lang":"tw","x_late":"韌體 - PCIe NVMe 儲存磁碟"},{"lang":"en","x_late":"Firmware - PCIe NVMe Storage Disk"},{"lang":"ko","x_late":"펌웨어 - PCIe NVMe 스토리지 디스크"},{"lang":"cn","x_late":"固件 - PCIe NVMe存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: VO001920KWZQR and VO003840KWZQT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;NVMe SSD&nbsp;Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPK5<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPK3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n\n<p style=\"text-align:left\"><strong>Known Issues:</strong></p>\n\n<p style=\"text-align:left\">&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"9400814","datemodified":"2021-07-25T12:31:58","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/CP048238.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/GP173300HPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2af7385a1e-HPK5-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048238.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048238.scexe"],"md5sum":"a10cf1e1bd07cbe479d33347d1c365e2","name":"firmware-hdd-2af7385a1e-HPK5-4.1.x86_64.rpm","release":"2021-07-25T12:18:13","revision":"0","sha1sum":"486f7bab1c33f37f8769ae8c76ff2516a80f6d41","size":"8MB","target_guids":["562340a5-304f-3130-3932-304b575a5152","562340a5-304f-3330-3834-304b575a5154"],"type_of_change":"2","version":"HPK5"}],"id":{"product":"18e9f59fd9934421b3a1eafac327542f","version":"404b375e73944e9b9a29f14fe1ecce1a"},"installation":{"command":"CP041863.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left: 30pt;\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul>\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容を抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>Rpmの内容を次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容を抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left: 30pt;\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left: 30pt;\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p>画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KWZQR and VO003840KWZQT Drives"},{"lang":"ja","x_late":"オンラインNVMe SSDフラッシュコンポーネントfor Linux (x64) - VO001920KWZQRおよびVO003840KWZQTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"VO003840KWZQT","target_guid":"562340a5-304f-3330-3834-304b575a5154","type":"nvme"},{"id":"VO001920KWZQR","target_guid":"562340a5-304f-3130-3932-304b575a5152","type":"nvme"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-01T07:45:49","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>Optimized T-offset setting.</li>\n\t<li>Change MQES setting to 8192.</li>\n\t<li>Fixed LED Behavior misaligned specs issue.</li>\n\t<li>Fixed performance drop issue when 4+ SSD are installed.</li>\n\t<li>The Idle Power Management fix to keep the drive from entering and exiting the Lower Power Idle mode too frequently.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00112800en_us</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VO003840KWZQT","sw_key_expectedpath":"firmware:sd:NVME"},{"name":"VO001920KWZQR","sw_key_expectedpath":"firmware:sd:NVME"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JWFVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a5746564e","Version":"HPD4"},{"DeviceName":"MB004000JWFVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATRsnSD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57465650","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB002000JWFVN and MB004000JWFVP"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。MB002000JWFVNおよびMB004000JWFVP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB002000JWFVN and MB004000JWFVP Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16247490","datemodified":"2021-08-30T19:26:17","file_list":["/CP048318_BUILD_2.data","/CP048318.vmexe","/CP048318.vmexe64","/CP048318.vmfile","/CP048318_VMw.zip","/CP048318.xml","/payload.json","/CP048318_VMw.zip/index.xml","/CP048318_VMw.zip/vendor-index.xml","/CP048318_VMw.zip/metadata.zip","/CP048318_VMw.zip/vib20/CP048318/HPE_bootbank_CP048318_HPD4.2-7.0.0.15843807.vib","/CP048318_VMw.zip/metadata.zip/vendor-index.xml","/CP048318_VMw.zip/metadata.zip/vmware.xml","/CP048318_VMw.zip/metadata.zip/vibs/CP048318--763999349046404700.xml","/CP048318_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048318_HPD4.2-7.0.0.15843807.xml"],"md5sum":"a5966c7728f7237a4e37084c0f5adc5a","name":"CP048318.zip","release":"2021-08-30T19:21:03","revision":"0","sha1sum":"1011cd4f7cdd4772d559ef14236feed0603fb40b","size":"15MB","target_guids":["4d2340a5-3042-3230-3030-304a5746564e","4d2340a5-3042-3430-3030-304a57465650"],"type_of_change":"1","version":"HPD4","vib_list":[{"name":"CP048318","version":"HPD4.2-7.0.0.15843807"}]}],"id":{"product":"640faf1092b548cf896ce4ae4d6b3ae8","version":"88d844cee8174d70be98e050daa024bd"},"installation":{"command":"CP041752.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JWFVN and MB004000JWFVP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for VMware ESXi - MB002000JWFVNおよびMB004000JWFVPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB002000JWFVN","target_guid":"4d2340a5-3042-3230-3030-304a5746564e","type":"sas"},{"id":"MB004000JWFVP","target_guid":"4d2340a5-3042-3430-3030-304a57465650","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-04T10:15:42","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware provides a change to the Vendor ID in the VPD page that refers to HP instead of HPE.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWFVN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWFVP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"4893651","datemodified":"2021-07-23T08:10:49","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/CP048100.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/TATCATdsHPD4.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-f6d00bd17e-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048100.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048100.scexe"],"md5sum":"31302f9f366de8fc64b506c66c67a3c5","name":"firmware-hdd-f6d00bd17e-HPD4-2.1.x86_64.rpm","release":"2021-07-23T07:58:10","revision":"0","sha1sum":"3a2261b90ccc8798fa9f4614d59ae643786ee199","size":"4MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"07fc1a5a961a427ba3c2e3f341d3886e","version":"e5329206cea246008584e19ee21650c1"},"installation":{"command":"CP041750.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64)  - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-24T12:52:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"16842257","datemodified":"2021-08-27T11:52:48","file_list":["/CP048429_BUILD_3.data","/CP048429.vmexe","/CP048429.vmexe64","/CP048429.vmfile","/CP048429_VMw.zip","/CP048429.xml","/payload.json","/CP048429_VMw.zip/index.xml","/CP048429_VMw.zip/vendor-index.xml","/CP048429_VMw.zip/metadata.zip","/CP048429_VMw.zip/vib20/CP048429/HPE_bootbank_CP048429_HPD7.3-7.0.0.15843807.vib","/CP048429_VMw.zip/metadata.zip/vendor-index.xml","/CP048429_VMw.zip/metadata.zip/vmware.xml","/CP048429_VMw.zip/metadata.zip/vibs/CP048429-1200317002224867721.xml","/CP048429_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048429_HPD7.3-7.0.0.15843807.xml"],"md5sum":"8f82cc26c43c5ca0fdcc4a08caa4dcba","name":"CP048429.zip","release":"2021-08-27T11:48:13","revision":"0","sha1sum":"01546baba93b3007f1b35e8db97d2fa1068e97ea","size":"16MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7","vib_list":[{"name":"CP048429","version":"HPD7.3-7.0.0.15843807"}]}],"id":{"product":"09b4bcb98476436f9711a4ef6ff6b585","version":"5a89b51f58f94330b0808d9a1f641caa"},"installation":{"command":"CP043253.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T07:56:11","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\" style=\"color: blue; text-decoration: none;\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000150GWCNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3135-304757434e4e","Version":"HPG1"},{"DeviceName":"VK000240GWCNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3234-304757434e50","Version":"HPG1"},{"DeviceName":"VK000480GWCNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3438-304757434e51","Version":"HPG1"},{"DeviceName":"VK000960GWCNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3030-3936-304757434e52","Version":"HPG1"},{"DeviceName":"VK001600GWCNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"4IDVHPG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3130-3630-304757434e54","Version":"HPG1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR, and VK001600GWCNT Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG1</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;</p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"15854073","datemodified":"2021-08-27T08:58:05","file_list":["/CP048405_BUILD_4.data","/CP048405.vmexe","/CP048405.vmexe64","/CP048405.vmfile","/CP048405_VMw.zip","/CP048405.xml","/payload.json","/CP048405_VMw.zip/index.xml","/CP048405_VMw.zip/vendor-index.xml","/CP048405_VMw.zip/metadata.zip","/CP048405_VMw.zip/vib20/CP048405/HPE_bootbank_CP048405_HPG1.4-7.0.0.15843807.vib","/CP048405_VMw.zip/metadata.zip/vendor-index.xml","/CP048405_VMw.zip/metadata.zip/vmware.xml","/CP048405_VMw.zip/metadata.zip/vibs/CP048405-245563376691318975.xml","/CP048405_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048405_HPG1.4-7.0.0.15843807.xml"],"md5sum":"312475481c55b256fb34662549cae429","name":"CP048405.zip","release":"2021-08-27T08:52:31","revision":"0","sha1sum":"5dd277bcc601b9a45bd28e816cc23a019facb1b2","size":"15MB","target_guids":["562340a5-304b-3030-3135-304757434e4e","562340a5-304b-3030-3234-304757434e50","562340a5-304b-3030-3438-304757434e51","562340a5-304b-3030-3936-304757434e52","562340a5-304b-3130-3630-304757434e54"],"type_of_change":"1","version":"HPG1","vib_list":[{"name":"CP048405","version":"HPG1.4-7.0.0.15843807"}]}],"id":{"product":"1af1a5a1ad4c4d1883e16ca0bd801d36","version":"6f058c7df25543aea032cfd3c9354ee5"},"installation":{"command":"CP042539.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK000150GWCNN, VK000240GWCNP, VK000480GWCNQ, VK000960GWCNR and VK001600GWCNT Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK000150GWCNN、VK000240GWCNP、VK000480GWCNQ、VK000960GWCNR、およびVK001600GWCNTドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK001600GWCNT","target_guid":"562340a5-304b-3130-3630-304757434e54","type":"sata"},{"id":"VK000960GWCNR","target_guid":"562340a5-304b-3030-3936-304757434e52","type":"sata"},{"id":"VK000480GWCNQ","target_guid":"562340a5-304b-3030-3438-304757434e51","type":"sata"},{"id":"VK000240GWCNP","target_guid":"562340a5-304b-3030-3234-304757434e50","type":"sata"},{"id":"VK000150GWCNN","target_guid":"562340a5-304b-3030-3135-304757434e4e","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T03:10:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK000480GWCNQ","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000150GWCNN","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK001600GWCNT","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000960GWCNR","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"VK000240GWCNP","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains the driver for the HPE Intel ixgben Adapters running under VMware vSphere 7.0."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This product contains driver version&nbsp;1.10.3.0.</p>\n"}],"files":[{"bytes":"200287","datemodified":"2021-11-19T10:00:20","file_list":["/cp047115.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/index.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/vendor-index.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/metadata.zip","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/vib20/ixgben/INT_bootbank_ixgben_1.10.3.0-1OEM.700.1.0.15843807.vib","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/metadata.zip/vibs/ixgben-5361810902838692625.xml","/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807_18186714.zip/metadata.zip/bulletins/Intel-ixgben_1.10.3.0-1OEM.700.1.0.15843807.xml"],"md5sum":"7ec43fd5d3fcd9a420789ad8f266f92c","name":"cp047115.zip","release":"2021-11-19T09:56:05","revision":"0","sha1sum":"6ec0da4d6ace72aedbf0005d205f997cd88b1437","size":"195KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"type_of_change":"0","version":"2021.12.00","vib_list":[{"name":"ixgben","version":"1.10.3.0-1OEM.700.1.0.15843807"}]}],"id":{"product":"8dc1af4f4f75416590a7ddb9bd07a92c","version":"81ef78e8846344278b0240af1a86e2d3"},"installation":{"command":"","command_params":"maintenancemode=true","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the HPE Service Pack for ProLiant Remote Online</strong>:</p>\n\n<ol>\n\t<li>Place the SPP on a USB key using the <a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\">HPE USB Key Creator Utility</a>.</li>\n\t<li>Place the desired driver to be updated in the directory&nbsp;<em>/SPP20xxxxx/hp/swpackages</em>&nbsp;on the USB key.</li>\n\t<li>Mount the USB key on a remote server running Windows or Linux.&nbsp;</li>\n\t<li>Change directory&nbsp;to <em>/hp/swpackages</em> and execute <em>./hpsum.</em></li>\n\t<li>Select the &quot;Next&quot; button.&nbsp;</li>\n\t<li>Click &quot;Add Single Target.&quot;&nbsp;</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated.</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li>Follow Smart Update Manager steps and complete the update.</li>\n</ol>\n\n<p><strong>To update the driver using VMware tools:</strong></p>\n\n<ol>\n\t<li>Unzip the&nbsp;HPE component zip file to extract the driver zip file.</li>\n\t<li>Copy the driver zip file extracted in the previous step&nbsp;to the VMware host server.</li>\n\t<li>Unzip the driver zip file to obtain the driver offline bundle zip file.</li>\n\t<li>Use VMware vSphere Update Manager (VUM) or esxcli commands to install the driver offline bundle.</li>\n\t<li>Refer to VMware documentation for information on VUM and the esxcli commands for more information.</li>\n</ol>\n"},{"lang":"ja","x_late":"<p><strong>HPE Service Pack for ProLiantリモートオンラインからSmart Update Managerを使用する手順</strong></p>\n\n<ol>\n\t<li><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?sp4ts.oid=1008862658&lang=en&cc=us\">HPE USB Key Creator Utility</a>を使用して、SPPをUSBキーにコピーします。</li>\n\t<li>アップデートするドライバーをUSBキーの<em>/SPP20xxxxx/hp/swpackages</em>ディレクトリにコピーします。</li>\n\t<li>WindowsまたはLinuxを実行するリモートサーバーにUSBキーをマウントします。 </li>\n\t<li><em>/hp/swpackages</em>ディレクトリに移動し、<em>./hpsum</em>を実行します。</li>\n\t<li>\"次へ\"ボタンを選択します。 </li>\n\t<li>「シングルターゲットの追加」をクリックします。 </li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。</li>\n\t<li>ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li>Smart Update Managerの指示に従ってアップデートを行います。</li>\n</ol>\n\n<p><strong>VMware Toolsを使用してドライバーをアップデート:</strong></p>\n\n<ol>\n\t<li>ドライバーのzipファイルを抽出するために、HPEコンポーネントのzipファイルを解凍します。</li>\n\t<li>前の手順で抽出したドライバーのzipファイルをVMwareホストサーバーにコピーします。</li>\n\t<li>ドライバーオフラインバンドルのzipファイルを取得するために、ドライバーのzipファイルを解凍します。</li>\n\t<li>ドライバーオフラインバンドルをインストールするために、VMware vSphere Update Manager（VUM）またはesxcliコマンドを使用します。</li>\n\t<li>VUMおよびesxcliコマンドについて詳しくは、VMwareのドキュメントを参照してください。</li>\n</ol>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixgben Driver for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"512"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"1528","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c192d","type":"pci","ven":"8086"},{"dev":"1528","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1528103c211a","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D2","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d2","type":"pci","ven":"8086"},{"dev":"1563","subdev":"00D1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-1563159000d1","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d0","type":"pci","ven":"8086"},{"dev":"10ED","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10ed103c17d3","type":"pci","ven":"8086"},{"dev":"1515","subdev":"192D","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c192d","type":"pci","ven":"8086"},{"dev":"1515","subdev":"211A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-1515103c211a","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This product corrects the maximum supported number of virtual functions.</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product corrects an issue where non-working MAC anti-spoofing</li>\n\t<li>This product corrects an issue where incorrect values in virtual function counters</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"Intel-ixgben:1.10.3.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver.component:vmware:zip"},{"name":"ixgben:1.10.3.0-1OEM.700.1.0.15843807","sw_key_expectedpath":"driver:vmware:zip"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB008000JWJRQ and MB006000JWJRP"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MB008000JWJRQおよびMB006000JWJRP"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB008000JWJRQ and MB006000JWJRP Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3032464","datemodified":"2021-08-12T20:01:47","file_list":["cp049130.xml","cpqsetup.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"md5sum":"621d4170339fe9fabcdc84447c364a3a","name":"cp049130.exe","release":"2021-08-12T19:52:08","revision":"0","sha1sum":"1e811b8fedf32ad1f0041adcf9718d72c0d3840a","size":"2MB","target_guids":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"type_of_change":"1","version":"HPD9"}],"id":{"product":"0c95f7c054f047b69fbfe7c93264a982","version":"5cfad832192d444688629fb24108326c"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB008000JWJRQおよび MB006000JWJRPドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB008000JWJRQ","target_guid":"4d2340a5-3042-3830-3030-304a574a5251","type":"sas"},{"id":"MB006000JWJRP","target_guid":"4d2340a5-3042-3630-3030-304a574a5250","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:39:56","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>This firmware release provides additional protection against command timeouts.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>This firmware release provides additional protection against command timeouts.</li>\n\t<li>For more information, refer to HPE Customer Bulletin at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00117258en_us</a></li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWJRQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWJRP","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5700-764285-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F4","Version":"2.42.5700"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764283-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F2","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5056-764284-B21_Ax-CLP-8025-UEFI-14.11.49-FlexBoot-3.4.754.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F3","Version":"2.42.5056"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764286-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F5","Version":"2.42.5000"},{"DeviceName":"HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX3Pro-rel-2_42_5000-764282-B21_Ax-CLP-8025-UEFI-14.11.45-FlexBoot-3.4.752.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1007103C22F1","Version":"2.42.5000"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) adapter firmware on VMware ESXi 6.7"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware&nbsp;Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (764282-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1350110023</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (764283-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1360110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (764284-B21)</td>\n\t\t\t<td>2.42.5056</td>\n\t\t\t<td>HP_1370110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (764285-B21)</td>\n\t\t\t<td>2.42.5700</td>\n\t\t\t<td>HP_1380110017</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (764286-B21)</td>\n\t\t\t<td>2.42.5000</td>\n\t\t\t<td>HP_1390110023</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"19187482","datemodified":"2021-02-03T03:34:06","file_list":["/CP045903.vmexe","/CP045903.vmfile","/CP045903_VMw.zip","/CP045903.xml","/payload.json","/README.txt","/CP045903_VMw.zip/index.xml","/CP045903_VMw.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip","/CP045903_VMw.zip/vib20/CP045903/HPE_bootbank_CP045903_1.0.1-6.7.0.7535516.vib","/CP045903_VMw.zip/metadata.zip/vendor-index.xml","/CP045903_VMw.zip/metadata.zip/vmware.xml","/CP045903_VMw.zip/metadata.zip/bulletins/Smart-Component-CP045903_1.0.1-6.7.0.7535516.xml","/CP045903_VMw.zip/metadata.zip/vibs/CP045903-815716802762803397.xml"],"md5sum":"d6025d11031c1568d8eab8b71bb3ff06","name":"CP045903.zip","release":"2021-02-03T03:39:04","revision":"0","sha1sum":"f8d1daa1a0a32987ed82d774010a14b96cf560f9","size":"18MB","target_guids":["a6b1a447-382a-5a4f-15B3-1007103C22F4","a6b1a447-382a-5a4f-15B3-1007103C22F2","a6b1a447-382a-5a4f-15B3-1007103C22F3","a6b1a447-382a-5a4f-15B3-1007103C22F5","a6b1a447-382a-5a4f-15B3-1007103C22F1"],"type_of_change":"1","version":"1.0.5","vib_list":[{"name":"CP045903","version":"1.0.1-6.7.0.7535516"}]}],"id":{"product":"67519506663b4d259181b3f43ca2db43","version":"86f9d0e7891b4a37a4f6e38fd32f7de6"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Offline: &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>Remote Online, if the component is supported by SUM but is not yet part of an SPP:<br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at: <a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>Note: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>To use HPE Insight Control for vCenter: &nbsp;<br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>To update firmware from VMware ESXi operating system on target server: &nbsp;<br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) devices on VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1007","subdev":"22F4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f4","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F2","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f2","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f3","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F5","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f5","type":"pci","ven":"15b3"},{"dev":"1007","subdev":"22F1","subven":"103C","target_guid":"a6b1a447-382a-5a4f-15b3-1007103c22f1","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-10-16T19:30:14","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 2.42.5000:</strong><br />\n&nbsp;&nbsp; &nbsp;764282-B21<br />\n&nbsp;&nbsp; &nbsp;764286-B21&nbsp;&nbsp;</p>\n\n<p><strong>Firmware for the following devices are updated to 2.42.5056:</strong><br />\n&nbsp;&nbsp; &nbsp;764283-B21<br />\n&nbsp;&nbsp;&nbsp;&nbsp;764284-B21</p>\n\n<p><strong>Firmware for the following device&nbsp;is&nbsp;updated to 2.42.5700:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;764285-B21</p>\n\n<p><strong>New features in firmware version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>Added support for the following features.\n\t<ul>\n\t\t<li>new TLV: CX3_GLOBAL_CONF to enable/disable timestamp on incoming packets through mlxconfig configuration.</li>\n\t\t<li>User MAC configuration.</li>\n\t\t<li>Automatically collecting mstdump before driver reset.</li>\n\t\t<li>A&nbsp;mechanism to detect DEAD_IRISC (plastic) from TPT (iron) and raise an assert.</li>\n\t\t<li>A new field is added to &quot;set port&quot; command which notifies the firmware what is the user_mtu size.</li>\n\t</ul>\n\t</li>\n\t<li>Improved the debug ability for command timeout cases.</li>\n</ul>\n\n<p><strong>New features and changes&nbsp;in firmware version 2.42.5700.</strong></p>\n\n<ul>\n\t<li>Modified the mlx_cmd_get_mlx_link_status command return value to return &quot;Link Type = Ethernet&quot; in Ethernet adapter cards.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>Fixes in version 2.42.5000:</strong></p>\n\n<ul>\n\t<li>PortRcvPkts counter was prevented from being cleared after&nbsp;resetting it.</li>\n\t<li>The system&nbsp;Timed Out on the configuration cycle of&nbsp;the Virtual Functions (VFs) when more than 10 Virtual Functions&nbsp;performed FLR and the completion Time Out&nbsp;value was configured to a range of less than&nbsp;16 msec.</li>\n\t<li>The server hangs and results in NMI when running&nbsp;&ldquo;mlxfwtop &ndash;d mt4103_pci_cr0&rdquo; while&nbsp;restarting the driver in parallel (from a different&nbsp;thread). In this case, the downstream&nbsp;bridge over the device reported completion&nbsp;timeout error.</li>\n\t<li>In flow_steering,&nbsp;BMC could not receive a ping over&nbsp;IPV6 after running bmc_reboot.</li>\n\t<li>While closing the&nbsp;HCA, the RX packet caused bad access to&nbsp;resources that did not exist, and consequently caused the QPCGW or the irisc to get stuck.</li>\n\t<li>The master SMLID&nbsp;and the LID was either 0 or&nbsp;0xFFFF when the port was neither active nor&nbsp;armed.</li>\n\t<li>ibdump could not capture&nbsp;all MADs packets.</li>\n\t<li>link did not&nbsp;go up after reboot.</li>\n\t<li>Fixed a rare issue that cause the PCIe&nbsp;configuration cycle that arrived during the&nbsp;time of sw_reset to generate 2 completions.</li>\n\t<li>Network Controller Sideband Interface (NC-SI) did not&nbsp;work when adding the disable_static_steering_ini field in the ini file, due to&nbsp;memory allocation issue for this field in the&nbsp;scratchpad.</li>\n</ul>\n\n<p><strong>Fixes in version 2.42.5056:</strong></p>\n\n<ul>\n\t<li>Fixed an issue that resulted in reading from invalid I/O address on handover from UEFI boot to OS boot, when a port was configured as InfiniBand on a VPI adapter device.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HVLAeAsseFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB006000JWKGN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントは、次のドライブモデルのファームウェアを提供します: MB006000JWKGN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD1<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:<br />\n&nbsp; &nbsp; &nbsp; </strong>None</p>\n"}],"files":[{"bytes":"4303064","datemodified":"2021-07-23T18:23:01","file_list":["cp048677.xml","cpqsetup.exe","HVLAeAsseFD2.rel","payload.json","setup.dll"],"md5sum":"ebecbee7fb53861b9c545b0aba9fa6de","name":"cp048677.exe","release":"2021-07-23T18:15:05","revision":"0","sha1sum":"809dde939024709ce92767dc8c47204d43a5be6c","size":"4MB","target_guids":["4d2340a5-3042-3630-3030-304a574b474e"],"type_of_change":"1","version":"HPD2"}],"id":{"product":"3c5ca1f7884d46278989b90e474b83e1","version":"6aed724779ac4ec68b94959e4e7d2edb"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB006000JWKGN ドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB006000JWKGN","target_guid":"4d2340a5-3042-3630-3030-304a574b474e","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-17T08:54:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB006000JWKGN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB6000GVYYU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SMPN6TG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304756595955","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB6000GVYYU"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"3420176","datemodified":"2021-07-25T15:24:12","file_list":["cp048612.xml","cpqsetup.exe","payload.json","setup.dll","SMPN6TG2.rel"],"md5sum":"60bdb699138f4698820ba6ea7f3a2e46","name":"cp048612.exe","release":"2021-07-25T15:17:05","revision":"0","sha1sum":"ccb32bf1447365d9897e18a70ca5384316ec2d7f","size":"3MB","target_guids":["002340a5-4d00-3642-3030-304756595955"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"f620be56e3714dd58684aa99e9723c4b","version":"ff00e929cc4a462bb3b6b71e041e573b"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\" style=\"text-decoration-line: none; color: blue;\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB6000GVYYU Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) -  MB6000GVYYUドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB6000GVYYU","target_guid":"002340a5-4d00-3642-3030-304756595955","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T11:39:58","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000GVYYU","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This product contains be2net drivers for the HPE Blade Emulex 10/20GbE Server Adapters running under SUSE Linux Enterprise Server 15."},{"lang":"ja","x_late":"この製品には、SUSE Linux Enterprise Server 15で動作するHPE Blade Emulex 10/20GbE サーバーアダプター用のbe2net ドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"105347","datemodified":"2021-03-08T20:12:29","file_list":["./lib/modules/5.3.18-22-default","./lib/modules/5.3.18-22-default/updates","./lib/modules/5.3.18-22-default/updates/be2net","./lib/modules/5.3.18-22-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"beea0c660636fe82866a1376e594c8b8","name":"be2net_bl-kmp-default-12.0.1342.0_k5.3.18_22-1.sles15sp2.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"ae7b8285c1e582c955645fbd589f6604ec304971","size":"102KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"},{"bytes":"106974","datemodified":"2021-03-08T20:16:35","file_list":["./lib/modules/4.12.14-195-default","./lib/modules/4.12.14-195-default/updates","./lib/modules/4.12.14-195-default/updates/be2net","./lib/modules/4.12.14-195-default/updates/be2net/be2net.ko","./usr/share/smartupdate/be2net_bl-kmp-default/component.xml"],"md5sum":"76dac42c67bd014951471f0991bc9b0f","name":"be2net_bl-kmp-default-12.0.1342.0_k4.12.14_195-1.sles15sp1.x86_64.rpm","release":"2021-03-08T20:04:05","revision":"0","sha1sum":"a30cc46dbf6538d0dd24d2386e0e1b1ec89c475d","size":"104KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec77a8ea21"],"type_of_change":"0","version":"12.0.1342.0-1"}],"id":{"product":"e7f36bf9643a4e489310dc38c624a57b","version":"1a5ab721a91746cda8d949d335f821dd"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>The binary RPM package(s) provided by&nbsp;this product&nbsp;are pre-compiled kernel module drivers built specifically for the default inbox kernel&nbsp;(stock kernel) that ships with the Linux distribution.&nbsp; HPE has tested and approved these pre-compiled kernel module RPMs for use with the specified kernel.&nbsp;</p>\n\n<p>These pre-compiled RPM packages may not install or function as expected on a different kernel (e.g. errata kernel).&nbsp;If you are not using a default inbox kernel, you should&nbsp;download the driver source package (i.e. &lt;driver&gt;.src.rpm) and compile&nbsp;a new driver for your&nbsp;target system from the driver source.</p>\n\n<p>To find the location of the driver source RPM, execute&nbsp;the following command for&nbsp;the kernel module driver RPM:&nbsp; <strong><em>localhost&gt; rpm -qpi &lt;kernel module driver name&gt;.rpm</em></strong></p>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Drivers for SUSE Linux Enterprise Server 15"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバー for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2021-03-19T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>These drivers have been&nbsp;updated to maintain compatibility with the latest firmware.</p>\n","latest_fixes_x_late":"<p>These drivers have been recompiled with a build setting that allows SUM to identify them correctly for installation on systems they support.</p>\n"},{"curr_enhancements_x_late":"<p>This product now supports SUSE Linux Enterprise Server 15 SP2.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"},{"key":"03010201","value":"HPE Integrity Superdome X Server"},{"key":"03010202","value":"HPE Integrity Superdome X Server GH_NH"}],"sw_keys":[{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"},{"name":"be2net_bl-kmp-default","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10Gb Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C21D4","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E 10GBASE-T Dual Port Converged Network Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072015908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Converged Network Adapter (FCoE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072415908153","Version":"12.0.1345.0"},{"DeviceName":"HPE CN1200E-T 10GBASE-T Dual Port Converged Network Adapter  (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"brcmflashStandalone-windows-12.0.1345.0-1//firmware//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-072215908153","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Converged Network and Network only adapters. \n\n"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"7603832","datemodified":"2021-08-27T06:37:17","file_list":["brcmflashStandalone-windows-12.0.1345.0-1/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/firmware/oc14-12.0.1345.0.ufi","brcmflashStandalone-windows-12.0.1345.0-1/win/","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmflash.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/brcmwinlpcfg.bat","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmflash.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/BrcmMILI.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/brcmwinlpcfg.exe","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/firmware/","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/libbrcmdfc.dll","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/RM.INI","cp046768.xml","cpqsetup.exe","fwmatrix.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","brcmflashStandalone-windows-12.0.1345.0-1/win/x64/readme.txt","reference.xml"],"md5sum":"1f2a827375b730b7876ea0cd64241fc4","name":"cp046768.exe","release":"2021-08-27T06:22:14","revision":"0","sha1sum":"769b489b08b2ef9e5bfaf31e52e2e106df9ef651","size":"7MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C21D4","a6b1a447-382a-5a4f-10DF-0722103C21D4","a6b1a447-382a-5a4f-10DF-0720103C21D4","a6b1a447-382a-5a4f-10DF-072015908153","a6b1a447-382a-5a4f-10DF-072415908153","a6b1a447-382a-5a4f-10DF-072215908153"],"type_of_change":"1","version":"2021.10.01"}],"id":{"product":"3792f94db020466a8427ae92f8d0ad7e","version":"9754e84595644bf0a5f97bbf0b6dcd08"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p dir=\"LTR\">Download the Smart Component to a directory on your hard drive and change to that directory.</p>\n\n<p>The downloaded file is a self-extracting executable with a filename based on the Component Number.<br />\nFrom that drive and directory, execute the downloaded file.<br />\n<br />\nClick the &quot;Install&quot; button to proceed with the installation.</p>\n"},{"lang":"ja","x_late":"<p dir=\"LTR\">Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。</p>\n\n<p>ダウンロードされたファイルは、コンポーネント番号をファイル名に持つ自己解凍型実行可能ファイルです。<br />\nそのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br />\n<br />\n［インストール］ボタンをクリックして、インストールを開始します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Converged Network Adapters for Microsoft Windows Server 2016/2019(x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"1024"},"supported_devices":[{"dev":"0724","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c21d4","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072415908153","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072215908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:13:15","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" style=\"width:800px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot BIOS</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-T Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</td>\n\t\t\t<td>10Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE CN1200E Dual Port Converged Network Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE&nbsp;CN1200E-T Dual Port Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Fixed a behavior with internal engineering data display</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware version:</p>\n\n<p dir=\"LTR\">&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Speed</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Universal Boot Image</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Firmware</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">UEFI</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">Boot BIOS</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E Dual Port Converged Network Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE CN1200E-T Dual Port Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">20Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1277.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1345.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1269.0</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.0.1171.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd184934a314","Version":"1.00"},{"DeviceName":"HPE Apollo 2000 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TiogaPass-Release-1.00-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c574673f","Version":"1.00"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 2000 Gen10 Backplane Expander"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 2000 Gen10バックプレーンエキスパンダーを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Supplemental Update / Online ROM Flash Component for Linux &ndash; HPE Apollo 2000 Gen10 Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00(B)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; </strong>None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"},{"lang":"ja","x_late":"<p><strong>提供名：<br />\n     </strong>サプリメンタルアップデート / オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア</p>\n\n<p><strong>リリースバージョンおよび/または日付:</strong><br />\n     1.00(B)<br />\n<br />\n<strong>最新の推奨またはクリティカルバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>前のファームウェアバージョン：</strong><br />\n     1.00<br />\n<br />\n<strong>ファームウェアの関連性：</strong><br />\n     なし<br />\n<br />\n<strong>改善点/新しい機能：</strong></p>\n\n<ul>\n\t<li>SUSE Linux Enterprise Server 15 OSのサポートを追加しました</li>\n</ul>\n\n<p><strong>修正された問題点：</strong></p>\n\n<p><strong>     </strong>なし</p>\n\n<p><strong>既知の問題点：</strong><br />\n     なし</p>\n"}],"files":[{"bytes":"5246419","datemodified":"2018-09-25T13:59:51","file_list":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/CP037610.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/TiogaPass-Release-1.00-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-1.00-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP037610.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP037610.scexe"],"md5sum":"85ecb6e6cfe6fc900fa01a0c6c0a103e","name":"firmware-smartarray-9f082dffb4-1.00-2.1.x86_64.rpm","release":"2018-10-23T00:00:00","revision":"1","sha1sum":"1737d6844da1dbe5ea5a50bf4691f77f86f99a09","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd184934a314","b99dfb74-f0bc-464f-b418-cd18c574673f"],"type_of_change":"0","version":"1.00"}],"id":{"product":"b59071ade4f9427093d3054145f8756e","version":"f6958296a88d45ea87f64a0f531f8a89"},"installation":{"command":"CP037610.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p><strong><em>Updating firmware with rpm installed:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Install the firmware rpm using the command:&nbsp; <em>rpm -ivh &lt;rpm_filename&gt;.&nbsp; </em>This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location</li>\n\t<li>The CP037610.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-smartarray-9f082dffb4-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above&nbsp;</li>\n\t<li>To install firmware, you can execute <strong>ONE</strong> of the following commands:\n\t<ul>\n\t\t<li>./CP037610.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em> in the &#39;/usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n\t<li>To uninstall the rpm, run the command: <em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension</li>\n</ul>\n\n<p><strong><em>Updating firmware without installing the rpm:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>Extract the contents of the rpm using the command: <em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp; </em>This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*&#39; location and run <em>./setup</em> to update the firmware. The actual name of the &#39;firmware-smartarray-9f082dffb4-*&#39; folder is based on the version of the rpm installed in the step above</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory</li>\n</ul>\n\n<p><strong><em>Additional Information:</em></strong></p>\n\n<p>Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong></p>\n\n<p><strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the <a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>on a USB key using the <a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&amp;lang=en&amp;cc=us\"><u>USB Key&nbsp;Utility for Windows</u></a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /SPP20xxxxx/packages</li>\n\t<li>Run launch_sum.sh script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p><strong>Additional Information:</strong></p>\n\n<ul>\n\t<li>System AC/DC power cycle is required after a firmware update in order for the update to take effect and for hardware stability to be maintained.</li>\n\t<li>To perform a system AC/DC power cycle: &nbsp;Disconnect the power cords from the server, wait 5 seconds and then reinsert the power cords.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p><strong><em>rpmインストールによるファームウェアのアップデート:</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>コマンドを使用して、ファームウェアrpmをインストールします:  <em>rpm -ivh <rpm_filename>。  </em>これは、'/usr/lib/x86_64-linux-gnu' の場所へrpmの内容を解凍します。</li>\n\t<li>CP037610.scexeスクリプトは'scexe-compat'フォルダーにあります。'firmware-smartarray-9f082dffb4-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul>\n\t\t<li>./CP037610.scexe（'/usr/lib/x86_64-linux-gnu/scexe-compat'で実行）（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*'の場所に<em>./setup</em>を追加してください。</li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド: <em>rpm -e <rpm_package_name></em>（'.rpm' 拡張子の付いていないrpmファイル名）を実行します。</li>\n</ul>\n\n<p><strong><em>rpmのインストールなしでのファームウェアのアップデート：</em></strong></p>\n\n<ul style=\"list-style-type:square; margin-left:40px\">\n\t<li>rpmの内容を次のコマンドを用いて抽出します。 <em>rpm2cpio <rpm_filename>.rpm | cpio -id.  </em>これは、現在のディレクトリの‘usr’フォルダーへrpmの内容を抽出します。</li>\n\t<li>'usr/lib/x86_64-linux-gnu/firmware-smartarray-9f082dffb4-*'に移動し、ファームウェアをアップデートするために<em>./setup</em>を実行します。'firmware-smartarray-9f082dffb4-*'フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p><strong><em>追加情報：</em></strong></p>\n\n<p>ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容を解凍するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p> </p>\n\n<p><strong>Smart Update Managerを使用するには Service Pack for ProLiant から以下の手順に従ってください:</strong></p>\n\n<p><strong>オフライン：</strong></p>\n\n<ul>\n\t<li><a href=\"https://h20566.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658&lang=en&cc=us\"><u>USB Key Utility for Windows</u></a>を使用して、<a href=\"http://www.hpe.com/info/spp\"><u>Service Pack for ProLiant </u></a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/SPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>オンライン：</strong></p>\n\n<ul>\n\t<li>rootとしてログインします。（ROMアップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>アップデートに必要なファームウェアをSPP20xxxxx/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにあるlaunch_sum.shスクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p><strong>追加情報：</strong></p>\n\n<ul>\n\t<li>アップデートを有効にして、ハードウェアの安定性を維持するには、ファームウェアのアップデート後にシステムのAC/DC電源を再投入する必要があります。</li>\n\t<li>システムのAC/DC電源の再投入を実行するには、以下の手順に従ってください。 サーバーから電源コードを取り外し、5秒待ってから電源コードを再度取り付けます。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Backplane Expander Firmware"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Linux（x64） - HPE Apollo 2000 Gen10バックプレーンエキスパンダーファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"028F","subdev":"0601","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0601","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0600","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0600","type":"pci","ven":"9005"},{"dev":"193F","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-193f159000e4","type":"pci","ven":"103C"},{"dev":"A186","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a186159000e5","type":"pci","ven":"8086"},{"dev":"A1D6","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a1d6159000e6","type":"pci","ven":"8086"},{"dev":"A206","subdev":"00E5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a206159000e5","type":"pci","ven":"8086"},{"dev":"A256","subdev":"00E6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-8086-a256159000e6","type":"pci","ven":"8086"},{"dev":"028F","subdev":"0651","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0651","type":"pci","ven":"9005"},{"dev":"028F","subdev":"0650","subven":"103C","target_guid":"a6b1a447-382a-5a4f-9005-028f103c0650","type":"pci","ven":"9005"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":true},"release_date":"2019-10-04T14:11:43","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for SUSE Linux Enterprise Server 15 OS</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"U38","value":"HPE Apollo r2800 Gen10 24 SFF Flexible Configure-to-order Chassis"}],"sw_keys":[{"name":"Apollor2800Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"},{"name":"Tioga Pass","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE LPe1605 16Gb Fibre Channel Host Bus Adapter for BladeSystem c-Class","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//A12852812.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E200103C1956","Version":"12.8.528.12"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Mezzanine Fibre Channel host bus adapters."}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"5378724","datemodified":"2021-08-25T07:18:38","file_list":["/CP046786_BUILD_15.data","/CP046786.vmexe","/CP046786.vmexe64","/CP046786.vmfile","/CP046786_VMw.zip","/CP046786.xml","/payload.json","/CP046786_VMw.zip/index.xml","/CP046786_VMw.zip/vendor-index.xml","/CP046786_VMw.zip/metadata.zip","/CP046786_VMw.zip/vib20/CP046786/HPE_bootbank_CP046786_2021.10.01.15-6.7.0.7535516.vib","/CP046786_VMw.zip/metadata.zip/vendor-index.xml","/CP046786_VMw.zip/metadata.zip/vmware.xml","/CP046786_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046786_2021.10.01.15-6.7.0.7535516.xml","/CP046786_VMw.zip/metadata.zip/vibs/CP046786-1111166117241574316.xml"],"md5sum":"bc65a514af1d75ebd6c27be2584a404f","name":"CP046786.zip","release":"2021-08-25T07:13:15","revision":"0","sha1sum":"c92d4f0a3edaf826b9b2553f05aa74cf9a98d43e","size":"5MB","target_guids":["a6b1a447-382a-5a4f-10DF-E200103C1956"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046786","version":"2021.10.01.15-6.7.0.7535516"}]}],"id":{"product":"ab64ba8d4a0a499eb17eec922888ce81","version":"18a9f94c974e40939ceb4b2f3a4c244a"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated if the ESXi host is Gen9 Server or Enter the IP or DNS address of the iLO of the ESXi host if the Sever is Gen10 and above</li>\n\t<li>Enter the ESXi host/iLO credentials (root or administrator username and password) based on Gen9/Gen10 and above</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Mezzanine Fibre Channel Host Bus Adapters for VMware vSphere  6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"E200","subdev":"1956","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-e200103c1956","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T06:42:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\"><strong>Added the following:-</strong></p>\n\n<ul dir=\"ltr\">\n\t<li>Added support for Distributed Management Task Force (DMTF) &ndash; Platform Level Data Model (PLDM) Firmware Update to the SN1200E, SN1600E, and SN1610E</li>\n\t<li>The adapter will now reset to defaults when the user activates Hewlett Packard Enterprise (HPE) Secure Erase from Hewlett Packard Enterprise (HPE) intelligent provisioning</li>\n\t<li>Added support for Fabric Performance Impact Notifications (FPIN)</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.12</td>\n\t\t\t<td>12.8.352.10</td>\n\t\t\t<td>12.8.352.5</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p><strong>Fixed the following:-</strong></p>\n\n<ul>\n\t<li>Fixed a behavior&nbsp;where the SN1600E would wrongly display an unwanted message when loading Unified Extensible Firmware Interface (UEFI) driver defaults</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This Firmware package contains following firmware versions:&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE 16Gb LPe1605 Fibre Channel Host Bus Adapter for BladeSystem c-Class</td>\n\t\t\t<td>16Gb</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.12</td>\n\t\t\t<td>12.8.528.10</td>\n\t\t\t<td>12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Blade Emulex 10/20GbE Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Blade Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2016が含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1607040","datemodified":"2021-07-21T19:27:07","file_list":["bepnic.dll","bepnic.rtf","cp045173.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"ee0c489989fb8c80032aa73e04a0daee","name":"cp045173.exe","release":"2021-07-21T19:13:06","revision":"0","sha1sum":"ee7530c0102fa39511fed97f8c11ad5704b87459","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1344.0"}],"id":{"product":"950aa10923d94fe39adbfe18fa1f4f69","version":"cb83568273b94c7ab80ecf9d976c3b4f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Blade Emulex 10/20GbEドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1935","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-03T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>This driver addresses a Windows Stop Error (BSOD) seen after Windows Event ID 67.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on Linux Operating Systems."},{"lang":"ja","x_late":"このパッケージには、Linuxオペレーティングシステム上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"3280487","datemodified":"2022-02-07T09:16:44","file_list":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/CP050389.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050389.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050389.scexe"],"md5sum":"7f816f253647b4834cb5a78e300249b4","name":"firmware-nic-mellanox-eth-only-mft-1.0.6-1.1.x86_64.rpm","release":"2022-02-07T09:15:51","revision":"0","sha1sum":"486b4331f7792623ee3fcfd71ffdb6a0246a9310","size":"3MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.6"}],"id":{"product":"35cb34a457a347fd86df4f560cf6cf57","version":"deeafe7d44914e1b9e6c7941039ecfc2"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Updating firmware with rpm installed:</strong></p>\n\n<ul>\n\t<li>Install the RPM as: rpm -ivh &lt;rpm_filename&gt;.rpm. This will extract the contents to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CPxxxxxx.scexe script will be located in the &#39;scexe-compat&#39; folder.&nbsp;</li>\n\t<li>From the terminal, you can either call the &quot;./CPxxxxxx.scexe&quot; under &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR) &quot;./setup&quot; under &#39;firmware-nic-*&#39; location, to update the firmware (The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed).</li>\n\t<li>To uninstall, run: rpm -e &lt;rpm_package_name&gt;</li>\n</ul>\n\n<p><strong>Updating firmware without installing rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm as: rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id</li>\n\t<li>This will extract the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>From the terminal, navigate to &#39;usr/lib/x86_64-linux-gnu/firmware-nic-*&#39; location and run &quot;./setup&quot; to update the firmware. The actual name of the &#39;firmware-nic-*&#39; folder is determined based on the rpm installed.</li>\n</ul>\n"},{"lang":"ja","x_late":"<p><strong>rpmインストールによるファームウェアのアップデート:</strong></p>\n\n<ul>\n\t<li>RPMを次のコマンドでインストールします: rpm -ivh <rpm_filename>.rpm これは、'/usr/lib/x86_64-linux-gnu'へコンテンツを解凍します。</li>\n\t<li>CPxxxxxx.scexeスクリプトは、'scexe-compat'フォルダーにあります。 </li>\n\t<li>ターミナルから、'/usr/lib/x86_64-linux-gnu/scexe-compat'の下の\"./CPxxxxxx.scexe\"を呼び出すか、'firmware-nic-*'の下の\"./setup\"を呼び出してファームウェアをアップデートします('firmware-nic-*'フォルダーの実際の名前はインストールしたrmpによって異なります)。</li>\n\t<li>アンインストールするには、次のコマンドを実行します: rpm -e <rpm_package_name></li>\n</ul>\n\n<p><strong>rpmのインストールなしでのファームウェアのアップデート：</strong></p>\n\n<ul>\n\t<li>rpmの内容を次のコマンドで抽出します: rpm2cpio <rpm_filename>.rpm | cpio -id</li>\n\t<li>これは、現在のディレクトリの'usr'フォルダーへrpmの内容を解凍します。</li>\n\t<li>ターミナルから'usr/lib/x86_64-linux-gnu/firmware-nic-*'に移動し、ファームウェアをアップデートするために./setupを実行します。'firmware-nic-*'フォルダーの実際の名前は、インストールしたrpmによって異なります。</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（Linux x86_64）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T08:47:16","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.31.1014:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD1"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD1"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD1"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD1"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD1"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD1"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD1"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD1"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD1"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD1"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD1"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HBCQSssseFD1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD1"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFL およびEO001600JXBFN"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN&nbsp;Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD1<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5272927","datemodified":"2021-07-27T13:03:47","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/CP049153.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/HBCQSssseFD1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD1-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049153.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049153.scexe"],"md5sum":"f4981fad7c37ba7ff747fad97e234fd5","name":"firmware-hdd-24384980ec-HPD1-2.1.x86_64.rpm","release":"2021-07-27T12:52:08","revision":"0","sha1sum":"517aa7b2325083bbf0b68eb88177a9f88efc544a","size":"5MB","target_guids":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"type_of_change":"1","version":"HPD1"}],"id":{"product":"8d0bd1ce26004a9e8191551757cba42d","version":"f672bc23441f4266b6128820bc0970ee"},"installation":{"command":"CP040307.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux（x64）- MO000800JXBEV、MO001600JXBFP、MO003200JXBFQ、MO006400JXBFR、MO000960JXBFA、MO001920JXBFT、MO003840JXBFU、MO007680JXBGA、MO015360JXBFV、EO000400JXBEU、EO000800JXBFLおよびEO001600JXBFNドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO000800JXBEV","target_guid":"4d2340a5-304f-3030-3830-304a58424556","type":"sas"},{"id":"MO001600JXBFP","target_guid":"4d2340a5-304f-3130-3630-304a58424650","type":"sas"},{"id":"MO003200JXBFQ","target_guid":"4d2340a5-304f-3330-3230-304a58424651","type":"sas"},{"id":"MO006400JXBFR","target_guid":"4d2340a5-304f-3630-3430-304a58424652","type":"sas"},{"id":"MO000960JXBFA","target_guid":"4d2340a5-304f-3030-3936-304a58424641","type":"sas"},{"id":"MO001920JXBFT","target_guid":"4d2340a5-304f-3130-3932-304a58424654","type":"sas"},{"id":"MO003840JXBFU","target_guid":"4d2340a5-304f-3330-3834-304a58424655","type":"sas"},{"id":"MO007680JXBGA","target_guid":"4d2340a5-304f-3730-3638-304a58424741","type":"sas"},{"id":"MO015360JXBFV","target_guid":"4d2340a5-304f-3531-3336-304a58424656","type":"sas"},{"id":"EO000400JXBEU","target_guid":"452340a5-304f-3030-3430-304a58424555","type":"sas"},{"id":"EO000800JXBFL","target_guid":"452340a5-304f-3030-3830-304a5842464c","type":"sas"},{"id":"EO001600JXBFN","target_guid":"452340a5-304f-3130-3630-304a5842464e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-27T12:49:29","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;. Support for second source PMIC from IDT.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MO001920JXBFT","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000400JXBEU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000800JXBEV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003840JXBFU","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO003200JXBFQ","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO015360JXBFV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO001600JXBFN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO001600JXBFP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO000960JXBFA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO007680JXBGA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO000800JXBFL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO006400JXBFR","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD6"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD6"},{"DeviceName":"MB001000JWWPV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"SCIMARRNNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304a57575056","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB004000JWWQB, MB002000JWWQA and MB001000JWWPV"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD6</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp;&nbsp; None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>&nbsp;Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"18087435","datemodified":"2021-08-27T12:01:32","file_list":["/CP048431_BUILD_2.data","/CP048431.vmexe","/CP048431.vmexe64","/CP048431.vmfile","/CP048431_VMw.zip","/CP048431.xml","/payload.json","/CP048431_VMw.zip/index.xml","/CP048431_VMw.zip/vendor-index.xml","/CP048431_VMw.zip/metadata.zip","/CP048431_VMw.zip/vib20/CP048431/HPE_bootbank_CP048431_HPD6.2-7.0.0.15843807.vib","/CP048431_VMw.zip/metadata.zip/vendor-index.xml","/CP048431_VMw.zip/metadata.zip/vmware.xml","/CP048431_VMw.zip/metadata.zip/vibs/CP048431-8751542515098303286.xml","/CP048431_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048431_HPD6.2-7.0.0.15843807.xml"],"md5sum":"2fce5512ec5d8b51ac9f4b1c1b07a43b","name":"CP048431.zip","release":"2021-08-27T11:56:41","revision":"0","sha1sum":"1bc22304a8caa8e90df10b7e56199a7b61e77ea5","size":"17MB","target_guids":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141","4d2340a5-3042-3130-3030-304a57575056"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048431","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"b1381f6ec67b40269898593ac27aca95","version":"d2efdafe96924d7ab40eb718466b95a9"},"installation":{"command":"CP043266.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Ensure that CPXXXXXX.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPXXXXXX.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod x CPXXXXXX.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>From the same directory, execute the Smart Component. For example: ./CPXXXXXX.vmexe&nbsp; (or)&nbsp; ./CPXXXXXX.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/hp/swpackagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加します。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>CPXXXXXX.vmexe(ESXi 6.7 &以前のバージョン)およびCPXXXXXX.vmexe64(ESXi 7.0)は、次のコマンドを使用して実行可能です:</li>\n</ul>\n\n<p>             chmod x CPXXXXXX.vmexe    または    chmod x CPXXXXXX.vmexe64</p>\n\n<ul>\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例：./CPXXXXXX.vmexe(または)./CPXXXXXX.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります:rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB, MB002000JWWQA and MB001000JWWPV Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB004000JWWQB、MB002000JWWQA、およびMB001000JWWPVドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB004000JWWQB","target_guid":"4d2340a5-3042-3430-3030-304a57575142","type":"sas"},{"id":"MB002000JWWQA","target_guid":"4d2340a5-3042-3230-3030-304a57575141","type":"sas"},{"id":"MB001000JWWPV","target_guid":"4d2340a5-3042-3130-3030-304a57575056","type":"sas"}],"supported_operating_systems":[{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-10T09:00:34","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This firmware version updates the Vendor ID in the standard inquiry to &lsquo;HPE&rsquo;, in previous versions it was &lsquo;HP.&rsquo;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB002000JWWQA","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB001000JWWPV","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB004000JWWQB","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v2.56 (02/10/2022)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"A43_2.56_02_10_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v2.56 (02/10/2022)"}]},"PackageFormat":"Linux","Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央のロケーションからリモートサーバーのファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアをアップデートするために使用者がサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"33897806","datemodified":"2022-02-21T05:36:17","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/A43_2.56_02_10_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/CP050444.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-2.56_2022_02_10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP050444.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP050444.scexe"],"md5sum":"7ab7f497115896e36992a85899f2ce10","name":"firmware-system-a43-2.56_2022_02_10-1.1.x86_64.rpm","release":"2022-02-21T05:30:06","revision":"0","sha1sum":"55ecca49bbc6d1dfdcebdc89d4d0eb7e6c169c93","size":"32MB","target_guids":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"type_of_change":"2","version":"2.56_02-10-2022"}],"id":{"product":"be8e1065c14f4a6883e7804dae8c691e","version":"6af6a9e3272c40ca84caf69302f9508f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus（A43）サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-13T06:05:45","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Corrected Memory Error Threshold Events being logged to the Integrated Management Log (IML) incorrectly.  The system monitors corrected memory errors and notifies the user via a Corrected Memory Error Threshold Event when action is recommended due to an increased risk of an uncorrected memory error.  Previous versions of the System ROM may log a Corrected Memory Error Threshold Event in cases where the system is not at an increased risk of an uncorrected memory error.  It is strongly recommended that the System ROM be updated to this version or later before replacing DIMMs due to Corrected Memory Error Threshold Events.</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>None<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue that can result in Correctable Memory Error Threshold Events on DIMM slots 9/10/13/14/15/16 with AMD EPYC 7773/7573/7473/7373 CPU SKUs not being reported in the IML (Integrated Management Log).</p><p>Addressed an issue where RAID volumes will be lost when using the \"Restore Default Manufacturing Settings\" feature.</p><p>Addressed an issue where if the Administrator Password and Power-On Password are set, after clearing power-on password, Administrator Password is also cleared.</p><p>Addressed and issue where a system with Microsoft BitLocker enabled may incorrectly and intermittently prompt the user to unlock drives after a graceful OS reboot.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"}],"sw_keys":[{"name":"A43","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for Mellanox CX5 and CX6DX Ethernet NICs for Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Mellanox CX5およびCX6DX Ethernet NIC for Microsoft Windows Server 2016用のドライバーを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1985728","datemodified":"2021-12-07T10:00:49","file_list":["cp050316.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"md5sum":"8b62fb1d945222b9a1b009034ce82553","name":"cp050316.exe","release":"2021-12-07T09:47:05","revision":"0","sha1sum":"d379b89f14a45abc0559bf2583e2af582235f57f","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"type_of_change":"1","version":"2.80.25134.0"}],"id":{"product":"7c884a6e0000498786309bba3a9762e5","version":"c15b64e2897c4ce2ba5fe04a99d29ed9"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>[インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Mellanox CX5 and CX6DX Driver for Microsoft Windows Server 2016"},{"lang":"ja","x_late":"Mellanox CX5およびCX6DXドライバーfor Microsoft Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_devices":[{"dev":"1017","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30116","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30052","type":"pci","ven":"15B3"},{"dev":"1017","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101715b30117","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30042","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30102","type":"pci","ven":"15B3"},{"dev":"1015","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101515b30047","type":"pci","ven":"15B3"},{"dev":"101D","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101d15b30040","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0117","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30117","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0040","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30040","type":"pci","ven":"15B3"},{"dev":"101e","subdev":"0042","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30042","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0102","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30102","type":"pci","ven":"15B3"},{"dev":"1016","subdev":"0047","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101615b30047","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0116","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30116","type":"pci","ven":"15B3"},{"dev":"1018","subdev":"0052","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101815b30052","type":"pci","ven":"15B3"},{"dev":"101f","subdev":"0007","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30007","type":"pci","ven":"15b3"},{"dev":"101f","subdev":"0012","subven":"15b3","target_guid":"a6b1a447-382a-5a4f-15b3-101f15b30012","type":"pci","ven":"15b3"},{"dev":"101E","subdev":"0007","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30007","type":"pci","ven":"15B3"},{"dev":"101E","subdev":"0012","subven":"15B3","target_guid":"a6b1a447-382a-5a4f-15b3-101e15b30012","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-07T07:23:41","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>This product correct an issue which mlx5cmd tools reporting of the OS version that a VF is running.</li>\n\t<li>This product correct an issue which incorrect report related to the firmware traces to be logged ( FwTracer) &nbsp;feature on the VF</li>\n\t<li>This product correct an issue which prevented the package downgrade from replacing mlxdevx.dll in the system folder.</li>\n\t<li>This product correct an issue which cause TCP connection to drop&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p>This driver now allows the Event Viewer to overcome an OS limitation related to long names.</p>\n","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue which fixed a possible system crash when deleting vPort under Rx traffic.</li>\n\t<li>This product correct an issue which fixed an issue that allowed the installation process to be completed successfully even though one of the drivers was not updated.</li>\n\t<li>This product correct an issue which fixed an issue that caused traffic lose and connection closure when TCP Timestamp option (ts-val) is present and the MSB is set together with RSC.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"H10","value":"HPE Edgeline e920t Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920 Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"H10","value":"HPE Edgeline e920d Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"mlx5.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"7800032","languages":[{"lang":"fr","x_late":"Logiciel - Gestion du système"},{"lang":"en","x_late":"Software - System Management"},{"lang":"cn","x_late":"软件 - 系统管理"},{"lang":"tw","x_late":"軟體 ─ 系統管理"},{"lang":"de","x_late":"Software - Systemverwaltung"},{"lang":"ko","x_late":"소프트웨어 - 시스템 관리"},{"lang":"it","x_late":"Software - Gestione sistema"},{"lang":"ja","x_late":"ソフトウェア - システム マネジメント"},{"lang":"es","x_late":"Software - Administración del sistema"}]}],"description":[{"lang":"en","x_late":"Agentless Management Service (AMSD) provides support for Integrated Lights-Out 5 (iLO 5) Embedded Health and Alerting."},{"lang":"ja","x_late":"Agentless Management Service（AMSD）は、Integrated Lights Out 5（iLO 5）内蔵ヘルスおよびアラートのサポートを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"64","language":[{"lang":"tw","x_late":"Lights-Out"},{"lang":"en","x_late":"Lights Out"}]}],"documentation":[],"files":[{"bytes":"2891210","datemodified":"2021-12-06T05:24:07","file_list":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/cpqiScsi","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"md5sum":"30d416f02bab2371dc7aba2e45c08ae1","name":"amsd-2.6.0-1701.1.sles15.x86_64.rpm","release":"2021-12-06T05:12:05","revision":"0","sha1sum":"81029bccc9b5b851b729f9bc2a1024f5879be8a1","size":"2MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"type_of_change":"0","version":"2.6.0"}],"id":{"product":"cd4b5a9c9ed9405abbc5be7a9f037870","version":"6fe2b01c455a48e1aa6f16a2333249a9"},"installation":{"command":"","command_params":"","install_caps":{},"per_device_install_time_seconds":0,"reboot_details":[],"reboot_required":""},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Login as the system administrator (root), download the RPM to a directory on your hard drive and change to that directory.</p>\n\n<ul>\n\t<li>To install the package type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-&lt;version&gt;.rpm</li>\n\t</ul>\n\t</li>\n\t<li>To check whether the package is loaded properly type:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>Additional help is available by typing:\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"},{"lang":"ja","x_late":"<p>システム管理者（root）としてログインし、RPMをハードディスク上のディレクトリにダウンロードした後、そのディレクトリに移動します。</p>\n\n<ul>\n\t<li>パッケージをインストールするには、次のようにタイプします。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>rpm -Uvh amsd-<version>.rpm</li>\n\t</ul>\n\t</li>\n\t<li>パッケージが正しくロードされているか、以下をタイプして確認します。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>systemctl status amsd</li>\n\t\t<li>systemctl status smad</li>\n\t</ul>\n\t</li>\n\t<li>以下のコマンドを実行してヘルプを参照してください。\n\t<ul style=\"list-style-type:circle\">\n\t\t<li>man amsd</li>\n\t</ul>\n\t</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Agentless Management Service (iLO 5) for SUSE Linux Enterprise Server 15"}],"prerequisites":{"required_diskspace":{"size_kb":"0"},"supported_devices":[{"dev":"3307","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3307159000e4","type":"pci","ven":"103C"},{"dev":"3306","subdev":"00E4","subven":"1590","target_guid":"a6b1a447-382a-5a4f-103c-3306159000e4","type":"pci","ven":"103C"}],"supported_operating_systems":[{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-03T14:30:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>New support added to amsd:</p>\n\n<ul>\n\t<li>Enhance the direct-attached SATA Drive Status - smart Error&nbsp;and failed.</li>\n\t<li>Enhance the direct-attached SATA Drive Status under hot-plug and hot-remove.</li>\n\t<li>Provide the new OID, cpqIdeAtaDiskCapacityLowBytes and cpqIdeAtaDiskCapacityHighBytes for SATA HD capacity support</li>\n\t<li>HPE Synergy 4610C 10/25Gb Ethernet Adapter.</li>\n\t<li>HPE FC HBA/SN1700E</li>\n\t<li>HPE DSP DSC-25/100 Ent/Cld 10/25/100Gb</li>\n\t<li>Support for SUSE Linux Enterprise Server 15 Service Pack 3</li>\n</ul>\n","latest_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fixed the following items:</p>\n\n<ul>\n\t<li>The incorrect cpqSePciSlotWidth data may display due to data source, PCI max link, which is only for embedded devices. The fix uses the SMBIOS 9 for all the PCI devices as the priority.</li>\n\t<li>Users may see the 34464 Mbps NIC speed on the 100Gb NIC option because the data only shows the lower bits of the speed variable. The fix conducts the upper bits of the speed variable to present correct info.</li>\n\t<li>Users may see an empty entry for the SATA location due to leading space chars within SMBIOS. The fix removes the redundant space in the data.</li>\n\t<li>Provide the cpqScsi information (cpqSsci_rev.service) for the amsd reverse(agent) mode.</li>\n\t<li>Added protection to prevent the segfault under amsd reverse(agent) mode. This may happen when iLO does a reset without responses to amsd.</li>\n\t<li>Addressed the display of an&nbsp;IPV6 address that is shown in cpqNic when IPV6 support&nbsp;is disabled in the&nbsp;&nbsp;OS.</li>\n\t<li>Updated the driver vendor info in the AHS log.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A45","value":"HPE XL925g Quad Gen10 Plus EPYC Server"},{"key":"I44","value":"HPE Synergy 480 Gen10 Plus Compute Module"},{"key":"U61","value":"HPE ProLiant ML30 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U24","value":"HPE ProLiant XL2x260w Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"amsd","sw_key_expectedpath":"software:rpm"}],"upgrade_requirements":""}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1010-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binary for upgrading HPE Ethernet 10Gb 2-port 548SFP+ Adapter firmware on ESXi 6.7."},{"lang":"ja","x_late":"このパッケージには、ESXi 6.7上でHPE Ethernet 10Gb 2ポート548SFP+アダプターのファームウェアをアップグレードするためのユーティリティとバイナリが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>Mellanox Ethernet Only Adapters</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE Ethernet 10Gb 2-port 548SFP+ Adapter (P11338-B21)</td>\n\t\t\t<td>14.32.1010</td>\n\t\t\t<td>HPE0000000038</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"15960465","datemodified":"2022-02-14T07:01:05","file_list":["/CP050392.vmexe","/CP050392.vmfile","/CP050392.xml","/CP050392_VMw.zip","/payload.json","/CP050392_VMw.zip/index.xml","/CP050392_VMw.zip/vendor-index.xml","/CP050392_VMw.zip/metadata.zip","/CP050392_VMw.zip/vib20/CP050392/HPE_bootbank_CP050392_1.0.4-6.7.0.7535516.vib","/CP050392_VMw.zip/metadata.zip/vendor-index.xml","/CP050392_VMw.zip/metadata.zip/vmware.xml","/CP050392_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050392_1.0.4-6.7.0.7535516.xml","/CP050392_VMw.zip/metadata.zip/vibs/CP050392--3506359810161736166.xml"],"md5sum":"9038352935cd6ece894329e7a9f414cb","name":"CP050392.zip","release":"2022-02-14T07:16:48","revision":"0","sha1sum":"b8477c334fe3507f2f3d41d51583e461b83fea7f","size":"15MB","target_guids":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"type_of_change":"1","version":"1.0.6","vib_list":[{"name":"CP050392","version":"1.0.4-6.7.0.7535516"}]}],"id":{"product":"24a612c609984b6d85fe7fd4ee8bdcc3","version":"1014050acec645c7b5e6c693947443c3"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"no"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline: &nbsp; &nbsp;&nbsp;</strong><br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong>&nbsp;</p>\n\n<p style=\"margin-left:40px\">Enable SSH on the ESXi host.<br />\nLogin as root. (You must be logged in as root user in order to apply the update)&nbsp;<br />\nPlace the Smart Component in a temporary directory (Example /tmp/)<br />\nCheck if nmst module is loaded already using the command: vmkload_mod -l | grep nmst<br />\nIf the module is not loaded, use this command to load the module: vmkload_mod nmst<br />\n<br />\nUnzip the component.</p>\n\n<p style=\"margin-left:80px\"># unzip CPXXXXXX.zip</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">From the same directory, update the firmware using legacy Smart Component by executing vmexe&nbsp;file:</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\"># ./CPXXXXXX.vmexe</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">OR</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">Follow&nbsp;below steps to update the firmware using signed VIB:</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\"># esxcli software component apply -d /tmp/CPXXXXXX_VMw.zip</p>\n\n<p style=\"margin-left:80px\">Note : add&nbsp; --no-sig-check to signature checking needs to be skipped.</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\"># cd /opt/Smart_Component/CP0XXXXX/</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\"># Update the firmware by running the command &quot;./Execute_Component -s -f&quot;<br />\n&nbsp;</p>\n\n<p style=\"margin-left:80px\">Follow the directions given by the Smart Component.</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">Logout.</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">Disable SSH on the ESXi host.</p>\n\n<p style=\"margin-left:80px\">&nbsp;</p>\n\n<p style=\"margin-left:80px\">Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for  HPE Ethernet 10Gb 2-port 548SFP+ Adapter"},{"lang":"ja","x_late":"HPE Ethernet 10Gb 2ポート548SFP+アダプター用オンラインファームウェアアップグレードユーティリティ（ESXi 6.7）"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"1015","subdev":"02C1","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-1015159002c1","type":"pci","ven":"15B3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-09T08:51:13","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following device is&nbsp;updated to 14.31.1014:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n</ul>\n\n<p>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;</p>\n","latest_fixes_x_late":"<p><strong>Following issues have been fixed in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>TX PRBS was not changed even after reconfiguring it, all PRBS mode were enabled in test mode.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n</ul>\n\n<p style=\"margin-left:40px\"><strong>Additional Fixes included in version 14.31.1014:</strong></p>\n\n<ul>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.<br />\n\t&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following device has been updated to 14.32.1010:</strong></p>\n\n<ul>\n\t<li>P11338-B21 (HPE Ethernet 10Gb 2-port 548SFP+ Adapter)</li>\n</ul>\n\n<p><strong>New features and changes included in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Added 3 new assert filters (Health buffer, NVlog, FW trace). The assert will be exposed now if its severity level is equal to or above the new filter.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its &nbsp;rate limit.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it:PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a non-zero value.</li>\n\t<li>Limited the external loopback speed to the used module&#39;s capabilities.</li>\n\t<li>Improved linkup time when using the fast linkup capability.</li>\n\t<li>Added support for the slow_restart and slow_restart_idle parameters to enable Zero Touch RoCE capability.</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 14.32.1010:</strong></p>\n\n<ul>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The system could not create more than 128K QPs.</li>\n\t<li>On rare occasions, the system got into an unresponsive state when a peer port went down while using an Optical module.</li>\n\t<li>Packet Pacing rate was used if asymmetric VFs was enabled.</li>\n\t<li>Incorrect RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>Issue with RSS on IPSec flows in ConnectX-4 Lx led to performance degradation. In this scenario, the SPI optimization caused packets from a given host to hash to the same CPU core. The fix was to ignore SPI optimization according to l4_type in ConnectX-4 Lx adapter cards.</li>\n\t<li>The GetInventory NC-SI command reported leading 0xf in firmware version when it started with 0.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"","value":"HPE Apollo 6500 Gen10 Plus (Chassis)"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE Apollo n2600 24SFF Gen10 Plus CTO Chassis"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE Apollo 4100 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"}],"sw_keys":[{"name":"Mellanox_NIC_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06154-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06250-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.32.1010"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_32_1010-P06251-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.32.1010"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This package contains the utilities and binaries for upgrading HPE Mellanox VPI (Ethernet and Infiniband mode of operation) ConnectX6 adapter firmware on VMware ESXi 6.7"},{"lang":"ja","x_late":"このパッケージは、VMware ESXi 6.7上でHPE Mellanox VPI (EthernetおよびInfinibandモードで動作) ConnectX6アダプターファームウェアをアップグレードするためのユーティリティおよびバイナリを含みます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[{"lang":"en","x_late":"<p>This software package contains the following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td><strong>InfiniBand Card Type</strong></td>\n\t\t\t<td><strong>Firmware Version</strong></td>\n\t\t\t<td><strong>PSID</strong></td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter (P06154-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000034</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter (P06250-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000035</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter (P06251-B21)</td>\n\t\t\t<td>20.32.1010</td>\n\t\t\t<td>HPE0000000036</td>\n\t\t</tr>\n\t</tbody>\n</table>\n"}],"files":[{"bytes":"27993307","datemodified":"2022-02-05T14:01:17","file_list":["/CP050420.vmexe","/CP050420.vmfile","/CP050420.xml","/CP050420_VMw.zip","/payload.json","/CP050420_VMw.zip/index.xml","/CP050420_VMw.zip/vendor-index.xml","/CP050420_VMw.zip/metadata.zip","/CP050420_VMw.zip/vib20/CP050420/HPE_bootbank_CP050420_1.0.3-6.7.0.7535516.vib","/CP050420_VMw.zip/metadata.zip/vendor-index.xml","/CP050420_VMw.zip/metadata.zip/vmware.xml","/CP050420_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050420_1.0.3-6.7.0.7535516.xml","/CP050420_VMw.zip/metadata.zip/vibs/CP050420--4633501555103672255.xml"],"md5sum":"dd6eb91bab1323a3e70f787446bd11df","name":"CP050420.zip","release":"2022-02-05T17:14:05","revision":"0","sha1sum":"d6be6a3ce0382bbe71a736e5d232f37c38588c89","size":"26MB","target_guids":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"type_of_change":"1","version":"1.0.3","vib_list":[{"name":"CP050420","version":"1.0.3-6.7.0.7535516"}]}],"id":{"product":"f1f8da98d16b4dea87d58e2bbca62959","version":"8287edf07ffd42ae963b3561ec985fd4"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":360,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active","OSVersion":{"name":"Linux","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"4.11","description":"HPE Mellanox MFT Driver version 4.11 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>Offline:</strong>&nbsp;&nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>Remote Online, if the component is supported by SUM but is not yet part of an SPP:</strong><br />\n&nbsp; &nbsp; Download the appropriate SPP<br />\n&nbsp; &nbsp; Add the component to the SPP &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated<br />\n&nbsp; &nbsp; Run SUM<br />\n&nbsp; &nbsp; Add the ESXi host to be updated as a remote target/node &nbsp;<br />\n&nbsp; &nbsp; Enter IP or DNS address of the ESXi host to be updated &nbsp;<br />\n&nbsp; &nbsp; Enter the ESXi host credentials (root or administrator username and password) &nbsp;<br />\n&nbsp; &nbsp; For SUM 6.0 and newer, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.<br />\n&nbsp; &nbsp; Follow Smart Update Manager Steps to complete the firmware update<br />\n&nbsp; &nbsp; Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx\">https://techlibrary.hpe.com/us/en/enterprise/servers/products/service_pack/spp/index.aspx</a></p>\n\n<p>&nbsp;</p>\n\n<p><strong>Note</strong>: While updating firmware using SUM, &quot;View Devices&quot; option on the review page does not list the exact name of the adapter. This is an expected behavior and does not affect the functionality of the component.</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To use HPE Insight Control for vCenter: &nbsp;</strong><br />\n&nbsp; &nbsp; Log in to the vSphere Client &nbsp; &nbsp;&nbsp;<br />\n&nbsp; &nbsp; Select a server or cluster in the inventory tree &nbsp;<br />\n&nbsp; &nbsp; Click the HPE Insight Management tab &nbsp; &nbsp;<br />\n&nbsp; &nbsp; Follow Insight Control for vCenter steps to update firmware using a Smart Component</p>\n\n<p>&nbsp;</p>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server: &nbsp;</strong><br />\n&nbsp; &nbsp; Enable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Login as root. (You must be root in order to apply the update) &nbsp;<br />\n&nbsp; &nbsp; Place the Smart Component in a temporary directory<br />\n&nbsp; &nbsp; Check if the nmst module is loaded already: vmkload_mod -l | grep nmst<br />\n&nbsp; &nbsp; If module is not loaded, use the command to load the module: vmkload_mod nmst<br />\n&nbsp; &nbsp; From the same directory, execute the Smart Component. For example: unzip CPXXXXXX.zip; ./CPXXXXXX.vmexe<br />\n&nbsp; &nbsp; Follow the directions given by the Smart Component.<br />\n&nbsp; &nbsp; Logout.<br />\n&nbsp; &nbsp; Disable SSH on the ESXi host.<br />\n&nbsp; &nbsp; Reboot your system, if required, for the firmware update to take effect.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Firmware Upgrade Utility (ESXi 6.7) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 6.7"},{"lang":"ja","x_late":"オンラインファームウェアアップグレードユーティリティ (ESXi 6.7) for HPE Mellanox VPI (EthernetおよびInfinibandモード) ConnectX6デバイス - VMware ESXi 6.7"}],"prerequisites":{"required_diskspace":{"size_kb":"8000"},"supported_devices":[{"dev":"101B","subdev":"02AB","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ab","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AE","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002ae","type":"pci","ven":"15b3"},{"dev":"101B","subdev":"02AF","subven":"1590","target_guid":"a6b1a447-382a-5a4f-15b3-101b159002af","type":"pci","ven":"15b3"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-01-10T07:06:17","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p><strong>Firmware for the following devices are updated to 20.31.1014:</strong></p>\n\n<p style=\"margin-left:40px\">HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter - P06154-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter - P06250-B21<br />\nHPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter - P06251-B21</p>\n\n<p><strong>New features and changes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>NIC scheduling feature support has been disabled for non-privileged functions.</li>\n\t<li>Implemented a new NC-SI command get_debug_info to get mstdump via the NC-SI protocol to debug a device if the PCI link fails for any given reason.</li>\n\t<li>Updated the NC-SI speed reporting output to support 200GbE speed. Now when running the NC-SI command, the output presents 200GbE speed as well.</li>\n\t<li>support for Enabling/Disabling NIC and RDMA (port/partition) was included via the UEFI HII system settings.</li>\n\t<li>Increased the maximum number of MSIX per VF to 127.</li>\n\t<li>Asymmetrical MSIX Configuration: This feature allows the device to be configured with a different number of MSIX vectors per physical PCI functions.To use this feature, please follow these steps:\n\t<ul>\n\t\t<li>Clear NUM_PF_MSIX_VALID to disable global symmetrical MSIX configuration.</li>\n\t\t<li>Set PF_NUM_PF_MSIX_VALID to enable asymmetrical per Physical Function MSIX configuration.</li>\n\t\t<li>Configure PF_NUM_PF_MSIX per physical PCI function.</li>\n\t</ul>\n\t</li>\n\t<li>RDMA partitioning and RDMA counters in IB mode.</li>\n\t<li>Added a new bit (&quot;data_in_order&quot;) to query the QP and allow a process/library to detect when the AR is enabled.</li>\n\t<li>A new flex parser to support GENEVE hardware offload and ICMP.</li>\n\t<li>When the non-page-supplier-FLR funcion is initiated, the firmware triggers a page event to the page supplier to indicate that all pages should be returned for the FLR function.</li>\n\t<li>Enabled UID 0 to create resources with UMEM (User Memory).</li>\n\t<li>Receiving and sending native IB packets from/to the software (including all headers) via raw IBL2 QPs.</li>\n\t<li>RX RDMA NIC flow table on an IB port. Now the software can steer native IB packets to raw IB receive queues according to the DLID and &nbsp;the DQPN. &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</li>\n</ul>\n","latest_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Occasional performance issues related to RC QPs using E2E-credits (not connected to SRQ and doing send/receive traffic) when the ROCE_ACCL tx_window was enabled.</li>\n\t<li>A fatal error occurred and eventually resulted in the HCA to get into an unresponsive state when a packet was larger than a strided receive WQE that was being scattered.</li>\n\t<li>A rare issue that caused RX pipe to unresponsive state.</li>\n\t<li>The resource number size (a 64 bit number) was overwritten with a 32 bit number and erased the high bits when de-allocating the resource number.</li>\n\t<li>CRT_DCR with index larger than 1 &lt;&lt; 21 occasionally collided with the CRT_SW_RESERVED address.</li>\n\t<li>An issue that caused the TX queue to get into an unresponsive state when the VF rate limiter was set.</li>\n\t<li>In InfiniBand non-virtualization system, due to a corrupted steering root, traffic fails after a warm reboot.&nbsp;&nbsp;</li>\n</ul>\n\n<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br />\n<strong>Additional Fixes included in version 20.31.1014:</strong></p>\n\n<ul>\n\t<li>Disabled the CNP counter &ldquo;rp_cnp_ignored &quot; (triggered by OOS (out-of-sequence)) when all ports are IB.</li>\n\t<li>Fixed the TMP421 sensor temperature reporting.</li>\n\t<li>Fixed the rate select mechanism in QSFP modules.</li>\n\t<li>Fixed classification issues for &quot;Passive&quot; cables to be more robust.</li>\n\t<li>Initialized the rate table in the static configuration so it will be configured at the link-not-up scenarios.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</li>\n\t<li>Improved PortXmitWait IB counter accuracy.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p><strong>Firmware for the following devices has been updated to 20.32.1010:</strong></p>\n\n<ul>\n\t<li>HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe3 x16 MCX653105A-HDAT Adapter - P06154-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe3 x16 MCX653105A-ECAT Adapter - P06250-B21</li>\n\t<li>HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe3 x16 MCX653106A-ECAT Adapter - P06251-B21</li>\n</ul>\n\n<p><strong>New features and changes included in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>Added support for blocking unwanted GMP classes by dedicated MADs.</li>\n\t<li>Added a new NvConfig parameter LOG_MAX_QUEUE to set the maximum number of work queue resources (QP, RQ, SQ...) that can be created per function. The default value is 2^17.</li>\n\t<li>Added a Congestion Control Key to all Congestion Control MADs to authenticate that they are originated from a trusted source.</li>\n\t<li>Added an SMP firewall to block the option of sending SMPs (MADS sent on QP0 from the Subnet Manager) from unauthorized hosts to prevent fake SMPs from being recognized as the SM.</li>\n\t<li>Vendor Specific MADs Class 0x9 is no longer supported by the firmware. If case the firmware detects such MAD, the firmware will return a &quot;NOT SUPPORTED&quot; error to the user.</li>\n\t<li>Blocked the VF&#39;s ability to use both padding and signature in order to prevent the NIC from getting into an unresponsive state.</li>\n\t<li>Enabled Rate Limit per VM instead of VM-TC. This capability is implemented by adding support to a new Scheduling element type: rate limit elements that will connect to the rate_limit and will share its rate limit.</li>\n\t<li>Performance improvements in the DCT with AR flow by exposing a hint to the software in DCI software context that indicates that RDMA WRITE on this DCI is not supported.</li>\n\t<li>Added support for dynamic timeout mechanism when in InfiniBand mode.</li>\n\t<li>Added support for QSHR access register to enable Set and Query rate limit per-host per-port.</li>\n\t<li>The firmware now exposes a new Software Steering ICM resource for VXLAN encap expand in order for the SW Steering to manage this resource directly.</li>\n\t<li>Added support for asymmetrical VFs per PF. To enable it: PF_NUM_OF_VF_VALID must be true, and PF_NUM_OF_VF to a none zero value.</li>\n\t<li>Added 2 new MAD access registers to enable mlxlink to read/write access registers by LID (to the whole subnet).</li>\n\t<li>Enabled the exposure of new ICM resource to the software steering for VXLAN encapsulation expansion.</li>\n\t<li>Added support for DSFP AOC (CMIS) v4 when error code is not reported by the module.</li>\n\t<li>Limited the external loopback speed according to the used module&#39;s capabilities.</li>\n\t<li>Modified the Effective BER calculation method. Due to this, the value of the Effective BER will be slightly higher, however the link quality remains the same as prior to this change.</li>\n\t<li>This firmware version includes the following PCIe changes:\n\t<ul>\n\t\t<li>Fixed the ACS Port Number field in DSPs and ACS Egress Control Vector field in DSPs.</li>\n\t\t<li>Added support for VSC on USP of PCIe Switch.</li>\n\t\t<li>Fixed the mapping of Legacy Interrupts in the PCIe Switch.</li>\n\t\t<li>Fixed MRRS &amp; MPS configurations in DSPs.</li>\n\t</ul>\n\t</li>\n</ul>\n","curr_fixes_x_late":"<p><strong>The following issues have been fixed in version 20.32.1010:</strong></p>\n\n<ul>\n\t<li>System could not create more than 128K QPs.</li>\n\t<li>Incorrect indication of the PCIe link down in the AER registers on PCIe switch upstream port.</li>\n\t<li>Invalid RNR timeout when trying to set it during the rts2rts_qp transition.</li>\n\t<li>The flash frequency on boot was lower than expected (under 50Mhz). The issue was fixed by enabling the firmware to increase it on boot2 to normal frequency.</li>\n\t<li>A race condition between DC QP flush and DC packets that led to stuck slices in the hardware. To avoid such situation, firmware keeps the TCU drop set until QP flush is done.</li>\n\t<li>Firmware got into an unresponsive state and caused unexpected behavior when connecting an optical transceiver that support RxLOS and the remote side port was down.</li>\n\t<li>The link status was reported incorrectly and consequently caused the link to go down due to incorrect definition of the RX_LOS polarity in the INI.</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"02020001","value":"HPE Superdome Flex 280"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"03020102","value":"HPE Superdome Flex 2"},{"key":"03020101","value":"HPE Superdome Flex Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"Mellanox_VPI_CX6_MFT","sw_key_expectedpath":"firmware:nic"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWTFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757544645","Version":"HPG7"},{"DeviceName":"MB014000GWTFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG07abHPG7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757544646","Version":"HPG7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB012000GWTFE and MB014000GWTFF"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp; </strong>Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp; &nbsp; &nbsp;</strong>HPG7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp;&nbsp; HPG6<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16275499","datemodified":"2021-08-26T14:12:34","file_list":["/CP048336_BUILD_2.data","/CP048336.vmexe","/CP048336.vmexe64","/CP048336.vmfile","/CP048336_VMw.zip","/CP048336.xml","/payload.json","/CP048336_VMw.zip/index.xml","/CP048336_VMw.zip/vendor-index.xml","/CP048336_VMw.zip/metadata.zip","/CP048336_VMw.zip/vib20/CP048336/HPE_bootbank_CP048336_HPG7.2-7.0.0.15843807.vib","/CP048336_VMw.zip/metadata.zip/vendor-index.xml","/CP048336_VMw.zip/metadata.zip/vmware.xml","/CP048336_VMw.zip/metadata.zip/vibs/CP048336-8581921282004777982.xml","/CP048336_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048336_HPG7.2-7.0.0.15843807.xml"],"md5sum":"ddccbdf304ecb51c6edddb7baf879905","name":"CP048336.zip","release":"2021-08-26T14:07:16","revision":"0","sha1sum":"602d52518dec62ddc4f5407c446c16629d1d20dc","size":"15MB","target_guids":["4d2340a5-3042-3231-3030-304757544645","4d2340a5-3042-3431-3030-304757544646"],"type_of_change":"1","version":"HPG7","vib_list":[{"name":"CP048336","version":"HPG7.2-7.0.0.15843807"}]}],"id":{"product":"e6ce1a91bd5b4f829c98f53210189206","version":"61934bc349d348f4bc2d986d9beab645"},"installation":{"command":"CP042459.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWTFE and MB014000GWTFF Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB012000GWTFEおよびMB014000GWTFFドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB014000GWTFF","target_guid":"4d2340a5-3042-3431-3030-304757544646","type":"sata"},{"id":"MB012000GWTFE","target_guid":"4d2340a5-3042-3231-3030-304757544645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T20:38:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWTFE","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MB014000GWTFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300214","languages":[{"lang":"fr","x_late":"Pilote - Contrôleur de stockage"},{"lang":"en","x_late":"Driver - Storage Controller"},{"lang":"cn","x_late":"驱动程序 - 存储控制器"},{"lang":"tw","x_late":"驅動程式 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Treiber - Speichercontroller"},{"lang":"ko","x_late":"드라이버 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Driver - Controller di memorizzazione"},{"lang":"ja","x_late":"ドライバ - ストレージ コントローラ"},{"lang":"es","x_late":"Controlador - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This driver, MegaSAS35, provides Windows 64-bit support for HPE Smart Array MR controllers"},{"lang":"ja","x_late":"このドライバーMegaSAS35は、HPE SmartアレイMRコントローラー用のWindows 64-bitサポートを提供します"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"892256","datemodified":"2021-09-08T05:06:49","file_list":["cp049479.xml","cpqsetup.exe","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"md5sum":"5b6db124a8da0d76c8ba7dce8c4d35ab","name":"cp049479.exe","release":"2021-09-08T05:04:33","revision":"0","sha1sum":"d070005e495db89a74c580211132ac68e3dcf2e0","size":"871KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"type_of_change":"1","version":"7.716.3.0"}],"id":{"product":"8dad994cacb24e87b613f12e36f4c8c5","version":"c2b7bb717569440ab07244b1d29f3619"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":400,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.</p>\n\n<p>From that drive and directory, execute the downloaded file.</p>\n"},{"lang":"ja","x_late":"<p>Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己抽出型の実行ファイルです。</p>\n\n<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE MR416i-p,MR416i-a, MR216i-p, MR216i-a 64-bit controller driver for Microsoft Windows 2016 edition."},{"lang":"ja","x_late":"HPE MR416i-p、MR416i-a、MR216i-p、MR216i-a 64-bitコントローラードライバーfor Microsoft Windows 2016 edition。"}],"prerequisites":{"required_diskspace":{"size_kb":"1440"},"supported_devices":[{"dev":"10E2","subdev":"0293","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e215900293","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032A","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032a","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032B","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032b","type":"pci","ven":"1000"},{"dev":"10E2","subdev":"032C","subven":"1590","target_guid":"a6b1a447-382a-5a4f-1000-10e21590032c","type":"pci","ven":"1000"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-10-07T11:23:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Initial build</p>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Initial build</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"MegaSas35.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"AC963EEB-ED78-4F36-8CC1-29D85F34A0AC","Devices":{"Device":[{"DeviceName":"HPE 16GB NVDIMM Single Rank x4 DDR4-2666","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"hpe_16gib_skh_v1_04_2666.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"805DD01C-EB5A-1E76-80AD-80AD80AD80AD","Version":"1.04"}]},"Type":"Firmware","UpdatableBy":["Uefi"],"package":{"category":[{"key":"2900365","languages":[{"lang":"en","x_late":"Firmware - NVDIMM"},{"lang":"ja","x_late":"ファームウェア - NVDIMM"}]}],"description":[{"lang":"en","x_late":"This firmware package provides updated firmware for HPE 16GB NVDIMM-N DDR4-2666 Modules. It can be installed online through the use of tools such as Smart Update Manager (SUM) and the RESTful Interface Tool (iLOrest) on supported Operating Systems. Additionally, when used in conjunction with SUM or iLOrest, this firmware package allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このファームウェアパッケージは、HPE 16GB NVDIMM-N DDR4-2666モジュールのアップデートされたファームウェアを提供します。これは、サポート対象のオペレーティングシステムでSmart Update Manager(SUM)やRESTfulインターフェイスツール(iLOREST)などのツールを使用して、オンラインでインストールできます。さらに、SUMまたはiLOrestと共に使用する場合、このファームウェアパッケージは、ユーザーが中央ロケーションからリモートサーバー上のファームウェアをアップデートすることを可能にします。このリモート展開機能により、ファームウェアのアップデートを実行するために、ユーザーがサーバーの存在する場所へ移動する必要がなくなります。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"114396","datemodified":"2021-06-10T11:58:04","file_list":["hpe_16gib_skh_v1_04_2666.bin","nvdimm-16gb_1.04.xml","payload.json"],"md5sum":"64c4fed5e27e4d38102ae1204818c717","name":"nvdimm-16gb_1.04.fwpkg","release":"2021-06-10T11:56:05","revision":"0","sha1sum":"03514d9d253cd543b8b3f4441b931fe3c7681055","size":"111KB","target_guids":["805DD01C-EB5A-1E76-80AD-80AD80AD80AD"],"type_of_change":"1","version":"1.04"}],"id":{"product":"058a033acd864749bc51a480576695e0","version":"fe38f67181fa490a8f46c8fe683c331f"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To flash this firmware package, use the following iLOrest command. &nbsp;See&nbsp;<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>&nbsp;to download the latest version of the iLOrest tool.</p>\n\n<p>localhost OS example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt;&nbsp;</em></strong></p>\n\n<p>remote example:<br />\n<strong><em>ilorest flashfwpkg &lt;file_name.fwpkg&gt; --url &lt;iLO5_IP_Address&gt; -u &lt;iLO5_username&gt; -p &lt;iLO5_password&gt;</em></strong></p>\n\n<p>&nbsp;</p>\n\n<p>This firmware package can also be installed with the latest version of Smart Update Manager (SUM).</p>\n\n<p><strong>Supplemental updates</strong>&nbsp;for supported ProLiant servers and options can be done by using SUM, which is found on the <strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant</a></strong> (SPP) ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;firmware packages and components&nbsp;to be updated in the directory&nbsp;&quot;\\packages&quot; on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n\n<p>Reboot your system for the update to take effect immediately.</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p>このファームウェアパッケージをフラッシュするには、次のiLOrestコマンドを使用します。 iLOrestツールの最新バージョンをダウンロードするには、<u><a href=\"http://www.hpe.com/servers/resttool\">http://www.hpe.com/servers/resttool</a></u>を参照してください。</p>\n\n<p>ローカルホストOSの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> </em></strong></p>\n\n<p>リモートの例：<br />\n<strong><em>ilorest flashfwpkg <file_name.fwpkg> --url <iLO5_IP_Address> -u <iLO5_username> -p <iLO5_password></em></strong></p>\n\n<p> </p>\n\n<p>このファームウェアパッケージは、Smart Update Manager（SUM）の最新バージョンでもインストールできます。</p>\n\n<p>サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、<strong><a href=\"http://www.hpe.com/info/spp\" style=\"text-decoration-line: none; color: blue;\">Service Pack for ProLiant</a></strong> (SPP) ISO上にあるSUMを使用して実行できます。</p>\n\n<ul>\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">USB Key Utility</a></strong>を使用して、Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートに必要なファームウェアパッケージおよびコンポーネントをUSBキーの\"\\packages\"ディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n\n<p>アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Firmware Package - 16GB NVDIMM-N DDR4-2666"},{"lang":"ja","x_late":"ファームウェアパッケージ - 16GB NVDIMM-N DDR4-2666"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"ven_ad80&dev_ad80&subsys_ad80ad80","target_guid":"805dd01c-eba5-1e76-ad80-ad80ad80ad80","type":"nvdimm"}],"supported_operating_systems":[{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"0","minor":"0","name":"Cross Operating System","platform":"oi","sr":"OEM"},{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T02:07:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now supports Microsoft Windows Server 2019, Red Hat Enterprise Linux 8, SUSE Linux Enterprise Server 15 and VMware ESXi 7.0.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Add Microsoft Windows Server 2022 support.</li>\n\t<li>Add VMWare&nbsp;vSphere 6.5&nbsp;U3 support.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"80AD80AD80AD80AD","sw_key_expectedpath":"firmware:nvdimm"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB4000JEXYA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3442-3030-304a45585941","Version":"HPD9"},{"DeviceName":"MB6000JEXYB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TTMRESD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-3642-3030-304a45585942","Version":"HPD9"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB4000JEXYA and MB6000JEXYB"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。 MB4000JEXYAおよびMB6000JEXYB"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD9<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD8<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPD8</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None.</p>\n\n<p>&nbsp;<strong>Known Issues:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n"}],"files":[{"bytes":"16233342","datemodified":"2021-08-26T20:10:14","file_list":["/CP048369_BUILD_2.data","/CP048369.vmexe","/CP048369.vmexe64","/CP048369.vmfile","/CP048369_VMw.zip","/CP048369.xml","/payload.json","/CP048369_VMw.zip/index.xml","/CP048369_VMw.zip/vendor-index.xml","/CP048369_VMw.zip/metadata.zip","/CP048369_VMw.zip/vib20/CP048369/HPE_bootbank_CP048369_HPD9.2-7.0.0.15843807.vib","/CP048369_VMw.zip/metadata.zip/vendor-index.xml","/CP048369_VMw.zip/metadata.zip/vmware.xml","/CP048369_VMw.zip/metadata.zip/vibs/CP048369-7910780000386806495.xml","/CP048369_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048369_HPD9.2-7.0.0.15843807.xml"],"md5sum":"d4996d54dc6545f9cda75c0d9df4ddf8","name":"CP048369.zip","release":"2021-08-26T20:05:19","revision":"0","sha1sum":"35f223d77db3b3feffad771cc13974160b1679b0","size":"15MB","target_guids":["002340a5-4d00-3442-3030-304a45585941","002340a5-4d00-3642-3030-304a45585942"],"type_of_change":"1","version":"HPD9","vib_list":[{"name":"CP048369","version":"HPD9.2-7.0.0.15843807"}]}],"id":{"product":"1bfd9c2e979e4c999fa2978061e8b412","version":"9f43d2e224554a129b092d1ce7da8507"},"installation":{"command":"CP040533.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB4000JEXYA and MB6000JEXYB Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB4000JEXYAおよびMB6000JEXYBドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB4000JEXYA","target_guid":"002340a5-4d00-3442-3030-304a45585941","type":"sas"},{"id":"MB6000JEXYB","target_guid":"002340a5-4d00-3642-3030-304a45585942","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-07T20:14:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U1</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB6000JEXYB","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB4000JEXYA","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE FlexFabric 20Gb 2-port 650FLB Adapter (BLOM)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650FLB Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1935","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (iSCSI)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0722103C1934","Version":"12.0.1345.0"},{"DeviceName":"HPE FlexFabric 20Gb 2-port 650M Adapter (Mezz)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0724103C1934","Version":"12.0.1345.0"},{"DeviceName":"HP FlexFabric 20Gb 2-port 650M Adapter (NIC)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//oc14-12.0.1345.0.ufi","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-0720103C1934","Version":"12.0.1345.0"}]},"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900095","languages":[{"lang":"fr","x_late":"Micrologiciel - Réseau"},{"lang":"en","x_late":"Firmware - Network"},{"lang":"cn","x_late":"固件 - 网络"},{"lang":"tw","x_late":"韌體 ─ 網路"},{"lang":"de","x_late":"Firmware - Netzwerk"},{"lang":"ko","x_late":"펌웨어 - 네트워크"},{"lang":"it","x_late":"Firmware - Rete"},{"lang":"ja","x_late":"ファームウェア - ネットワーク"},{"lang":"es","x_late":"Firmware - Red"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware for Mezzanine Converged Network adapters."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"13150626","datemodified":"2021-08-20T08:17:28","file_list":["/CP046755_BUILD_6.data","/CP046755.vmexe","/CP046755.vmexe64","/CP046755.vmfile","/CP046755_VMw.zip","/CP046755.xml","/payload.json","/CP046755_VMw.zip/index.xml","/CP046755_VMw.zip/vendor-index.xml","/CP046755_VMw.zip/metadata.zip","/CP046755_VMw.zip/vib20/CP046755/HPE_bootbank_CP046755_2021.10.01.6-7.0.0.15843807.vib","/CP046755_VMw.zip/metadata.zip/vendor-index.xml","/CP046755_VMw.zip/metadata.zip/vmware.xml","/CP046755_VMw.zip/metadata.zip/vibs/CP046755-2432597108161047154.xml","/CP046755_VMw.zip/metadata.zip/bulletins/Smart-Component-CP046755_2021.10.01.6-7.0.0.15843807.xml"],"md5sum":"cf38919a56384256af414cf6de827fe2","name":"CP046755.zip","release":"2021-08-20T08:12:05","revision":"0","sha1sum":"061a787aec37b8e9401407312c73ff5b8777c509","size":"12MB","target_guids":["a6b1a447-382a-5a4f-10DF-0724103C1935","a6b1a447-382a-5a4f-10DF-0722103C1935","a6b1a447-382a-5a4f-10DF-0720103C1935","a6b1a447-382a-5a4f-10DF-0722103C1934","a6b1a447-382a-5a4f-10DF-0724103C1934","a6b1a447-382a-5a4f-10DF-0720103C1934"],"type_of_change":"1","version":"2021.10.01","vib_list":[{"name":"CP046755","version":"2021.10.01.6-7.0.0.15843807"}]}],"id":{"product":"c8a46fd2450f49dda4e8a0e964d64309","version":"11aa8de17b094a838a7f7130a4fe54c4"},"installation":{"command":"hpsetup","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the&nbsp;Service Pack for ProLiant:<br />\nOffline:</strong></p>\n\n<ul>\n\t<li>Service Pack ProLiant Offline mode boots a special Linux OS environment, thus the Linux Smart Component are used, not the VMware Smart Components</li>\n</ul>\n\n<p><strong>Remote Online, <strong>if the component is supported by SUM but is not yet part of an SPP:</strong></strong></p>\n\n<ul>\n\t<li>Download the appropriate Service Pack for ProLiant</li>\n\t<li>Add the component to the Service Pack for ProLiant</li>\n\t<li>Mount the&nbsp;Service Pack for ProLiant on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated</li>\n\t<li>Run Smart Update Manager via launch_sum.bat for Windows or launch_sum.sh for Linux</li>\n\t<li>Add the ESXi host to be updated as a remote target/node</li>\n\t<li>Enter the IP or DNS address of the ESXi host to be updated</li>\n\t<li>Enter the ESXi host credentials (root or administrator username and password)</li>\n\t<li>For Smart Update Manager 6.0 and newer, select both the Additional Package with the added component and the Service Pack for ProLiant Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n\t<li>Refer to the Service Pack for ProLiant Documentation for detailed instructions at: <a href=\"http://www.hpe.com/servers/spp/download\">www.hpe.com/servers/spp/download</a></li>\n</ul>\n\n<p><strong>To use HPE Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client.</li>\n\t<li>Select a server or cluster in the inventory tree.</li>\n\t<li>Click the HPE Insight Management tab.</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the Smart Component (CPxxxxxx.zip) in a temporary directory.</li>\n\t<li>From the same directory, unzip the Smart Component.\n\t<ul>\n\t\t<li>unzip CPxxxxxx.zip</li>\n\t</ul>\n\t</li>\n\t<li>The smart component includes CPxxxxx_VMw.zip which consists of VIB which needs to be installed to perform firmware installation</li>\n\t<li>Ensure that the file CPxxxxxx_VMw.zip is executable. Execute the command:\n\t<ul>\n\t\t<li>chmod +x CPxxxxxx_VMw.zip</li>\n\t</ul>\n\t</li>\n\t<li>To perform the standalone installation, execute the command:</li>\n\t<li>esxcli software vib install -d /&lt;path_of_CPxxxxxx_VMw.zip&gt;/CPxxxxxx_VMw.zip</li>\n\t<li>Once the installation completes, change directory to /opt/Smart_Component/&lt;CPxxxxxx&gt;. Execute the comand:\n\t<ul>\n\t\t<li>cd /opt/Smart_Component/&lt;CPxxxxxx&gt;</li>\n\t</ul>\n\t</li>\n\t<li>To perform standalone installation of the firmware,Execute the command:\n\t<ul>\n\t\t<li>./ Execute_Component</li>\n\t</ul>\n\t</li>\n\t<li>Follow the directions given by the Smart Component</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n\t<li>Reboot your system, if required, for the firmware update to take effect</li>\n</ul>\n\n<p>&nbsp;</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Firmware Flash for Emulex Mezzanine Converged Network Adapters for VMware vSphere 7.0"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"0724","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"},{"dev":"0724","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0724103c1934","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-03-04T05:47:50","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1336.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":"<p dir=\"LTR\"><strong>Fixed the following:</strong></p>\n\n<ul>\n\t<li>Fixed a behavior with internal engineering data displays</li>\n</ul>\n"},{"curr_enhancements_x_late":"<p dir=\"LTR\">Updated CNA (XE100 series) firmware</p>\n\n<p>This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td>Adapter</td>\n\t\t\t<td>Speed</td>\n\t\t\t<td>Universal Boot Image</td>\n\t\t\t<td>Firmware</td>\n\t\t\t<td>UEFI</td>\n\t\t\t<td>Boot Bios</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650FLB Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td>HPE FlexFabric 20Gb 2-port 650M Adapter</td>\n\t\t\t<td>20Gb</td>\n\t\t\t<td>12.0.1277.0</td>\n\t\t\t<td>12.0.1345.0</td>\n\t\t\t<td>12.0.1269.0</td>\n\t\t\t<td>12.0.1171.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"}],"sw_keys":[{"name":"emulex_cna","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050868.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.04.601"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 SPS firmware that can be installed directly on supported Operating Systems. "},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"3803816","datemodified":"2022-01-26T03:43:22","file_list":["cp050868.compsig","cp050868.zip","cp050869.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"90f97bc71da872eeb8fc4d19d1cabb55","name":"cp050869.exe","release":"2022-01-26T03:42:13","revision":"0","sha1sum":"809a0b8ee398b0a77c97e1fa05699772a7ec94fe","size":"3MB","target_guids":["a6b1a447-382a-5a4f-3c10-86800a000101"],"type_of_change":"0","version":"04.01.04.601"}],"id":{"product":"ffc5db5b28504df99cd08b4bf08ccc7d","version":"208454153dfb46ff9c6b0492a5213957"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"0.1.4.0","description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p style=\"margin-left:0px; margin-right:0px\"><strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;the Service Pack for ProLiant (SPP) ISO&nbsp;except for Edgeline blades which are not supported by the Service Pack for ProLiant (SPP) ISO</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option1:</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li>Place the Service Pack for ProLiant on a USB key using the <strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&amp;sp4ts.oid=1008862658\">USB Key Creator Utility</a></strong>.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n\t<li>Boot the server to the USB key to update the firmware and software&nbsp;in the usual manner.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">Option 2:</p>\n\n<ul>\n\t<li>Mount the SPP ISO</li>\n\t<li>Copy the desired update component(s) in a temporary directory.</li>\n\t<li>Start SUM and navigate to the Baseline Library panel.</li>\n\t<li>Select Add from the Actions menu and add the mounted SPP.</li>\n\t<li>Select Add from the Actions menu and add the temporary directory as an Additional Packages folder.</li>\n\t<li>Select Create Custom from the Actions menu and create a custom SPP using both imported SPP and the Additional Packages.</li>\n\t<li>Launch the remote console from the iLO on the managed server and mount the newly created custom SPP via Virtual Media.</li>\n\t<li>Restart the server to boot to the SPP to perform the install.</li>\n</ul>\n\n<p>Note that this mechanism can be scripted through iLO for performing updates to multiple servers.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください:</p>\n\n<p>1.      コンポーネントをテンポラリディレクトリに置きます。<br />\n2.     同じディレクトリからダブルクリックしてコンポーネントを実行します。<br />\n3.     コンポーネントダイアログウィンドウが表示されたら、ファームウェアアップグレードを実行するためにインストールボタンをクリックします。<br />\n4.     アップデートを直ちに有効にするにはシステムを再起動してください。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">サポートされるProLiantサーバーおよびオプションのための<strong>Supplementalアップデート</strong>は、Service Pack for ProLiant (SPP) ISOでサポートされていないEdgelineブレードを除き、Service Pack for ProLiant (SPP) ISOを使用して実行できます。</p>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション1：</p>\n\n<ul style=\"list-style-type:disc\">\n\t<li><strong><a href=\"https://support.hpe.com/hpesc/public/home/driverHome?pmasr=0&sp4ts.oid=1008862658\">HP USB Key Utility</a></strong>を使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n\t<li>サーバーをUSBキーで起動して、ファームウェアとソフトウェアを通常の方法でアップデートします。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px\">オプション2：</p>\n\n<ul>\n\t<li>SPP ISOをマウントします</li>\n\t<li>目的のアップデートコンポーネントを一時ディレクトリにコピーします。</li>\n\t<li>SUMを起動し、ベースラインライブラリパネルに移動します。</li>\n\t<li>アクションメニューから追加を選択し、マウントされたSPPを追加します。</li>\n\t<li>アクションメニューから追加を選択し、追加パッケージフォルダーとして一時ディレクトリを追加します。</li>\n\t<li>アクションメニューからカスタムの作成を選択し、インポートされたSPPと追加パッケージの両方を使用してカスタムSPPを作成します。</li>\n\t<li>管理対象サーバーでiLOからリモートコンソールを起動し、仮想メディアを介して新しく作成したカスタムSPPをマウントします。</li>\n\t<li>サーバーを再起動して、インストールを実行するSPPを起動します。</li>\n</ul>\n\n<p>このメカニズムは、複数のサーバーに対するアップデートを実行するためにiLOによってスクリプト化できることに注意してください。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows x64 - HPE Gen10サーバー向けServer Platform Services(SPS)ファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1809 & later)","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minor":"0","name":"Microsoft Windows 10 (64bit, version 1803 & older)","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-26T03:40:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.1 guidance.</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>This version of the Server Platform Services (SPS) Firmware addresses an issue where not all PCIe devices will be managed properly by the system when there are more than 16 PCIe devices present in the platform. This would include PCIe devices in PCIe slots or NVMe drives. This issue would typically manifest itself as iLO Firmware not properly reporting thermals from a device when a server was in this heavily loaded configuration.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n"},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>This version of the Server Platform Services (SPS) Firmware contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Enhancements/New Features:</strong></p><p>This version is in compliance with IPU.2021.2 guidance.</p><p><strong>Known Issues:</strong></p>None","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"U45","value":"HPE Proliant XL270d Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910 Server Blade"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"I43","value":"HPE Synergy 660 Gen10 Compute Module"},{"key":"I42","value":"HPE Synergy 480 Gen10 Compute Module"},{"key":"U39","value":"HPE ProLiant XL420 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U39","value":"HPE Apollo 4200 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"H08","value":"HPE ProLiant e910t Server Blade"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"}],"sw_keys":[{"name":"SPS_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":false,"FileName":"cp050814.zip","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.039"}]},"PackageFormat":"Windows","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component provides updated HPE Gen10 Plus SPS firmware that can be installed directly on supported Operating Systems."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能な、アップデートされたHPE Gen10 Plus SPSファームウェアを提供します。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"2912608","datemodified":"2022-01-26T03:09:01","file_list":["cp050814.compsig","cp050814.zip","cp050815.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"md5sum":"5d6dc21b739cce408be4139c23d30630","name":"cp050815.exe","release":"2022-01-26T03:07:04","revision":"0","sha1sum":"c8f35bb05238d60ba3f94f97a35d4f13be2208b3","size":"2MB","target_guids":["a6b1a447-382a-5a4f-8086-43e080867270"],"type_of_change":"1","version":"06.00.03.039"}],"id":{"product":"10b8cebc40fb4b69b234ff81bd7e1d1f","version":"1eb4ac0b41e84d18945215e570ac7cfd"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":600,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Windows operating system on target server:</p>\n\n<p>1.&nbsp;&nbsp;&nbsp;&nbsp; Place the Component in a temporary directory.<br />\n2.&nbsp;&nbsp;&nbsp;&nbsp; From the same directory, run the Component by double-clicking it.<br />\n3.&nbsp;&nbsp;&nbsp;&nbsp; When the Component dialog window displays, click the Install button to initiate the firmware upgrade.<br />\n4.&nbsp;&nbsp;&nbsp;&nbsp; Reboot your system for the update to take effect immediately.</p>\n\n<p><strong>To verify the HPE SHA256 Authenticode digital signature, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Download cp047662.exe to a system running a supported version of Microsoft Windows Server OS. By downloading this file, you are agreeing to the license terms in HPE License Agreement v1.pdf, listed in the &#39;License&#39; field.<br />\n2. &nbsp; &nbsp;Right-click the filename then select Properties<br />\n3. &nbsp; &nbsp;When the Properties window displays, click the Digital Signature tab<br />\n4. &nbsp; &nbsp;Select the first entry in the Signature List and click the Details button.&nbsp;<br />\n5. &nbsp; &nbsp;The signature status will display at the top of the Details dialog.<br />\n6. &nbsp; &nbsp;If the signature message states that &ldquo;This digital signature is OK.&rdquo;, then the firmware package is authenticated as an HPE package<br />\n7. &nbsp; &nbsp;If the message &ldquo;This digital signature is not OK.&rdquo; displays, then do the following:<br />\n&nbsp; &nbsp; &nbsp; &nbsp; a. &nbsp; &nbsp;Do not deploy the firmware.<br />\n&nbsp; &nbsp; &nbsp; &nbsp; b. &nbsp; &nbsp;Download firmware a second time and verify the signature again. If the signature is not OK, then contact HPE Technical Support.&nbsp;</p>\n\n<p><br />\n<strong>To verify the SHA256 hash value, do the following steps:</strong><br />\n1. &nbsp; &nbsp;Use Microsoft Windows CRC/SHA tool to calculate the SHA256 hash value for cp047662.exe.&nbsp;<br />\n2. &nbsp; &nbsp;Compare the calculated value with the SHA256 value displayed in the Installation Instruction tab of the HPE Support Center download page.<br />\n&bull; &nbsp; &nbsp;If the values match, then the integrity of the downloaded file has been verified.<br />\n&bull; &nbsp; &nbsp;If the values do not match, do not deploy the file or its contents.<br />\n&bull; &nbsp; &nbsp;Download the file a second time and compare the new hash value.&nbsp;<br />\n&bull; &nbsp; &nbsp;If the hash values do not match, then do not deploy the downloaded file and contact HPE Technical Support.</p>\n\n<p>Execute the file &nbsp;cp047662.exe and follow onscreen instructions to finish the installation.<br />\nAfter the driver installaton is complete, please restart the server.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Windows x64 - Server Platform Services (SPS) ファームウェアfor HPE ProLiant DL20 Gen10 Plus"}],"prerequisites":{"required_diskspace":{"size_kb":"1000"},"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-20T09:37:06","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p><strong>Important Notes:</strong></p>\n\n<p>None</p>\n\n<p><strong>Firmware Dependencies:</strong></p>\n\n<p>None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<p>This version of the System ROM contains updates aligned with the Tatlow PLR2 BKC WW50.</p>\n\n<p><strong>Known Issues:</strong></p>\n\n<p>None</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"FTP","value":"FTP-Only System"},{"key":"U60","value":"HPE ProLiant DL20 Gen10 Plus Server"}],"sw_keys":[{"name":"SPS_UEFI_Gen10","sw_key_expectedpath":"firmware:sd:sps"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EK0800JVYPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-304b-3830-304a5659504e","Version":"HPD7"},{"DeviceName":"EO1600JVYPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4500-314f-3630-304a56595050","Version":"HPD7"},{"DeviceName":"MK0800JVYPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-304b-3830-304a56595051","Version":"HPD7"},{"DeviceName":"MO1600JVYPR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"PLTGIID7.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"002340a5-4d00-314f-3630-304a56595052","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"このSmartコンポーネントは、次のドライブモデルのファームウェアを提供します。EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Linux (x64)&nbsp;- EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPD7</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL:&nbsp;<a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"5195534","datemodified":"2021-07-23T09:20:00","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/CP048202.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/PLTGIID7.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-481c8ea9a7-HPD7-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048202.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048202.scexe"],"md5sum":"3c31d6cd6ac2d3c2458936d7b122c3ff","name":"firmware-hdd-481c8ea9a7-HPD7-4.1.x86_64.rpm","release":"2021-07-23T09:08:10","revision":"0","sha1sum":"a14dc2db10c1f56e3fc95e44f1dd45bf46f8ff4f","size":"4MB","target_guids":["002340a5-4500-304b-3830-304a5659504e","002340a5-4500-314f-3630-304a56595050","002340a5-4d00-304b-3830-304a56595051","002340a5-4d00-314f-3630-304a56595052"],"type_of_change":"2","version":"HPD7"}],"id":{"product":"189399e2f82a48ee85c54d779b410263","version":"83f8a4db53984c1097dbae958adb1a17"},"installation":{"command":"CP043252.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) -  EK0800JVYPN, EO1600JVYPP, MK0800JVYPQ and MO1600JVYPR Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Linux (x64) - EK0800JVYPN、EO1600JVYPP、MK0800JVYPQ、およびMO1600JVYPRドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MO1600JVYPR","target_guid":"002340a5-4d00-314f-3630-304a56595052","type":"sas"},{"id":"EO1600JVYPP","target_guid":"002340a5-4500-314f-3630-304a56595050","type":"sas"},{"id":"MK0800JVYPQ","target_guid":"002340a5-4d00-304b-3830-304a56595051","type":"sas"},{"id":"EK0800JVYPN","target_guid":"002340a5-4500-304b-3830-304a5659504e","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-28T11:19:21","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>&nbsp;Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"<ul>\n\t<li>The issue affects SSDs with an HPE firmware version prior to HPD7 that results in SSD failure at 40,000 hours of operation (i.e., 4 years, 205 days 16 hours), neither the SSD nor the data can be recovered, after the SSD failure occurs.</li>\n\t<li>In addition, SSDs which were put into service at the same time will likely fail nearly simultaneously.</li>\n\t<li>For more information, refer to HPE Customer Advisory at the following URL: <a href=\"https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us\">https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00097382en_us</a>.</li>\n</ul>","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EK0800JVYPN","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EO1600JVYPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MO1600JVYPR","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MK0800JVYPQ","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Critical"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWFVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a5746564b","Version":"HPD4"},{"DeviceName":"MB006000JWFVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TATCATdsHPD4.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5746564c","Version":"HPD4"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MB004000JWFVK and MB006000JWFVL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) -&nbsp;MB004000JWFVK and MB006000JWFVL&nbsp;Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD4<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPD3<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp; &nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3036072","datemodified":"2021-07-23T18:55:35","file_list":["cp048562.xml","cpqsetup.exe","payload.json","setup.dll","TATCATdsHPD4.REL"],"md5sum":"246fba3c6a68181f7e4d69c264afac8e","name":"cp048562.exe","release":"2021-07-23T18:48:05","revision":"0","sha1sum":"c7a999fc8d065bcf8623cdbc222ae6704f21a3a5","size":"2MB","target_guids":["4d2340a5-3042-3430-3030-304a5746564b","4d2340a5-3042-3630-3030-304a5746564c"],"type_of_change":"1","version":"HPD4"}],"id":{"product":"e0822b357e024225a58d203426c0d686","version":"195ef2bbd73c45eb818369020e4af28f"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWFVK and MB006000JWFVL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Windows (x64) - MB004000JWFVKおよびMB006000JWFVLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB004000JWFVK","target_guid":"4d2340a5-3042-3430-3030-304a5746564b","type":"sas"},{"id":"MB006000JWFVL","target_guid":"4d2340a5-3042-3630-3030-304a5746564c","type":"sas"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-16T06:55:48","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>There is no compelling reason to update this firmware. Risk is that whoever looks at the Vendor ID in the VPD page will notice that it refers to HP instead of HPE. There is no functional risk if not upgraded.&nbsp;</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.<br />\n\t&nbsp;</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB004000JWFVK","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB006000JWFVL","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOk":true,"FileName":"U40_2.62_03_08_2022.signed.flash","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"SysPowerON":false,"Type":"Firmware","UefiFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v2.62 (03/08/2022)"}]},"PackageFormat":"Linux","Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"1200212","languages":[{"lang":"fr","x_late":"BIOS - ROM système"},{"lang":"en","x_late":"BIOS - System ROM"},{"lang":"cn","x_late":"BIOS - ?? ROM"},{"lang":"tw","x_late":"BIOS - ?? ROM"},{"lang":"de","x_late":"BIOS - System-ROM"},{"lang":"ko","x_late":"BIOS - ??? ROM"},{"lang":"it","x_late":"BIOS - ROM di sistema"},{"lang":"ja","x_late":"BIOS - ????ROM"},{"lang":"es","x_late":"BIOS - ROM del sistema"}]}],"description":[{"lang":"en","x_late":"This component provides updated system firmware that can be installed directly on supported Operating Systems. Additionally, when used in conjunction with Smart Update Manager (SUM) and Insight Control for VMware vCenter, this Component allows the user to update firmware on remote servers from a central location. This remote deployment capability eliminates the need for the user to be physically present at the server in order to perform a firmware update."},{"lang":"ja","x_late":"このコンポーネントは、サポートされるオペレーティングシステム上で直接インストール可能なアップデートされたシステムファームウェアを提供します。 さらに、Smart Update Manager (SUM)およびInsight Control for VMware vCenterと共に使用する場合、このコンポーネントは、ユーザーが中央ロケーションから遠隔地にあるサーバーのファームウェアを更新することを可能にします。 このリモート展開機能により、ファームウェアをアップデートするためにユーザーがサーバーへ物理的に移動する必要がなくなります。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"11505916","datemodified":"2022-03-08T13:53:55","file_list":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/CP051283.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/U40_2.62_03_08_2022.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-2.62_2022_03_08-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP051283.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP051283.scexe"],"md5sum":"de8d875a7680f74b80a1bf27a78d3a47","name":"firmware-system-u40-2.62_2022_03_08-1.1.x86_64.rpm","release":"2022-03-08T13:44:12","revision":"0","sha1sum":"940b4a082e7b67d5e62e203a636d7e9c084d4a8e","size":"10MB","target_guids":["00000000-0000-0000-0000-00000000020f"],"type_of_change":"1","version":"2.62_03-08-2022"}],"id":{"product":"672edcd2af9a4bd18876e5e3192cd831","version":"4009120372974c03860d89e42d21513a"},"installation":{"command":"","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"name":"VMware","value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"name":"VMware","value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.0.3.9-1OEM","description":"HP CRU Driver for VMware ESXi 5.1"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"name":"VMware","value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"5.5.4.1-1OEM","description":"HP CRU Driver for VMware ESXi 5.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"name":"VMware","value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.0.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.0"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"6.5.8.0-1OEM","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"name":"VMware","value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"650.6.5.8","description":"HP CRU Driver for VMware ESXi 6.5"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939","description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Lights-Out Drivers and Agents for Linux"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP Channel Interface Driver for VMWare"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE Channel Interface Driver for VMware"},{"Condition":"AlreadyActive","DeviceGuid":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"name":"VMware","value":"*"},"RequirementGUID":"","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active"},{"Condition":"InstalledBefore","DeviceGuid":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"name":"Windows","value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"*","description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>To update firmware from Linux operating system on target server:<br />\n&nbsp;<br />\nInstall the RPM package<br />\n&gt; rpm -Uvh &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nSee where the files land<br />\n&gt; rpm -qlp &lt;filename&gt;.rpm<br />\n&nbsp;<br />\nChange to the directory you see in the previous step and run hpsetup by typing &lsquo;./hpsetup&rsquo; at the command prompt.<br />\n<br />\n<br />\n<strong>Supplemental updates</strong> for supported ProLiant servers and options can be done by using&nbsp;Smart Update Manager, which is found on the Service Pack for ProLiant ISO.</p>\n\n<ul>\n\t<li>Place the Service Pack for ProLiant on a USB key using the USB Key Creator Utility.</li>\n\t<li>Place the desired&nbsp;components&nbsp;to be updated in the directory, \\packages on the USB key.</li>\n</ul>\n\n<p>Update the firmware and software&nbsp;in the usual manner.</p>\n"},{"lang":"ja","x_late":"<p>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。<br />\n <br />\nRPMパッケージをインストールします。<br />\n>rpm -Uvh <filename>.rpm<br />\n <br />\nファイルの保存場所を確認してください。<br />\n>rpm -qlp <filename>.rpm<br />\n <br />\n前のステップで表示されたディレクトリに変更し、コマンドプロンプトで‘./hpsetup’とタイプしてhpsetupを実行します。<br />\n<br />\n<br />\nサポートされるProLiantサーバーおよびオプションのための<strong>サプリメンタルアップデート</strong>は、Service Pack for ProLiant ISOにあるSmart Update Managerから行うことができます。</p>\n\n<ul>\n\t<li>USB Key Utilityを使用して、HP Service Pack for ProLiantをUSBキーにコピーします。</li>\n\t<li>アップデートする予定のコンポーネントをUSBキーの\\packagesディレクトリにコピーします。</li>\n</ul>\n\n<p>通常の手順でファームウェアおよびソフトウェアをアップデートします。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers"},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネントfor Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) サーバー"}],"prerequisites":{"required_diskspace":{"size_kb":"11000"},"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"6","minor":"0","name":"Red Hat Enterprise Linux 6 Server (x86-64)","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"11","minor":"0","name":"SUSE LINUX Enterprise Server 11 (AMD64/EM64T)","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2022-04-04T03:11:39","revision_history":[{"lang":"en","latest_enhancements_x_late":null,"latest_fixes_x_late":"<p><strong>Important Notes:</strong></p>This version of the System ROM contains updates aligned with the Intel Product Update (IPU) version IPU.2021.2 guidance.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides BIOS mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0092, CVE-2021-0093, CVE-2021-0144. These issues are not unique to HPE servers. </p><p>This revision of the System ROM includes Intel Platform Update 2021.2. It provides Authenticated Code Module (ACM) mitigations for security vulnerabilities documented as INTEL-SA-00527 (2/8) for CVE-2021-0099, CVE-2021-0103,\nCVE-2021-0107, CVE-2021-0111, CVE-2021-0114, CVE-2021-0115, CVE-2021-0116, CVE-2021-0117, CVE-2021-0118, CVE-2021-0125, CVE-2021-0124. These issues are not unique to HPE servers.</p><p>Addressed an issue (SIK6906) where the systems with HPE NS204i-p NVMe OS Boot Device may shut down intermittently and may log the following System Overheating message in the Integrated Management Log (IML): \"System Overheating (Temperature Sensor 47, Location I/O Board, Temperature61) ACTION:Check fans, processor heat sink and air baffles installation.\"</p><p>Addressed an issue where the system may not automatically restart due to a hang condition during the boot process after a cold boot when the IPMI Watchdog Timer feature is enabled in the ROM-Based Setup Utility (RBSU).</p><p><strong>Known Issues:</strong></p>None"},{"curr_enhancements_x_late":null,"curr_fixes_x_late":"<p><strong>Important Notes:</strong></p>This System ROM should be considered Critical for any systems using the v2.60 revision of the System ROM.<p><strong>Firmware Dependencies:</strong></p>None<p><strong>Problems Fixed:</strong></p><p>Addressed an issue where the Advanced Memory Protection (AMP) mode was incorrectly forced to Advanced ECC from HPE Fast Fault Tolerant (ADDDC) mode after updating to Sysrom ROM 01/13/2022 v2.60.</p><p><strong>Known Issues:</strong></p>None","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"U40","sw_key_expectedpath":"firmware:system"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"M52004G3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive model: VK003840GWSXL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"16486555","datemodified":"2021-08-27T10:39:00","file_list":["/CP048410_BUILD_2.data","/CP048410.vmexe","/CP048410.vmexe64","/CP048410.vmfile","/CP048410_VMw.zip","/CP048410.xml","/payload.json","/CP048410_VMw.zip/index.xml","/CP048410_VMw.zip/vendor-index.xml","/CP048410_VMw.zip/metadata.zip","/CP048410_VMw.zip/vib20/CP048410/HPE_bootbank_CP048410_HPG3.2-7.0.0.15843807.vib","/CP048410_VMw.zip/metadata.zip/vendor-index.xml","/CP048410_VMw.zip/metadata.zip/vmware.xml","/CP048410_VMw.zip/metadata.zip/vibs/CP048410-145575630117397249.xml","/CP048410_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048410_HPG3.2-7.0.0.15843807.xml"],"md5sum":"a68b130f5971006a0372c8cceb555761","name":"CP048410.zip","release":"2021-08-27T10:34:09","revision":"0","sha1sum":"60b795b4d3142740242ae930401fe3b214791ca6","size":"15MB","target_guids":["562340a5-304b-3330-3834-30475753584c"],"type_of_change":"1","version":"HPG3","vib_list":[{"name":"CP048410","version":"HPG3.2-7.0.0.15843807"}]}],"id":{"product":"f2d480bbb5d747efac90df2828bbca07","version":"7eefa6e53c1949d180cc0f73930c6eda"},"installation":{"command":"CP040786.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>HP Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - VK003840GWSXLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"VK003840GWSXL","target_guid":"562340a5-304b-3330-3834-30475753584c","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T05:41:52","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Improved Product Quality and Reliability. Changed Cap Charge Timeout to 14 seconds from 4 seconds to provide additional time for cap charge in marginal power environment.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"VK003840GWSXL","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for the HPE Emulex 10/20 GbE Server Adapters for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、HPE Emulex 10/20GbEサーバーアダプタードライバー for Windows Server 2016を含んでいます。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"1613208","datemodified":"2020-06-12T11:05:50","file_list":["bepnic.dll","bepnic.rtf","cp044541.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","occfg.exe","ocnd65.cat","ocnd65.inf","ocnd65.sys"],"md5sum":"15cebde2a9436105658e4a57e87db28e","name":"cp044541.exe","release":"2020-06-12T10:52:05","revision":"0","sha1sum":"2bfc995dcd8113e38aff799c73cda3d66774cee5","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ecfe4a13f6"],"type_of_change":"0","version":"12.0.1195.0"}],"id":{"product":"a0c7bf6781ed49d0a1fa08387a0fba69","version":"b0dcc06402cc405fa2ceff7f256a9fe3"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>\n          [インストール]ボタンをクリックして、インストールを開始してください。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Emulex 10/20 GbE Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Emulex 10/20 GbEドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"1500"},"supported_devices":[{"dev":"0728","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c220a","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c21d4","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8144","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0720103c8144","type":"pci","ven":"10DF"},{"dev":"0720","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072015908153","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"220A","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c220a","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"21D4","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0728103c21d4","type":"pci","ven":"10DF"},{"dev":"0728","subdev":"8153","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-072815908153","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2020-07-11T01:46:20","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product now remove&nbsp;supports Synergy and Blade&nbsp;Server.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product now supports the following network adapters:</p>\n\n<ul>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-T Adapter</li>\n\t<li>HP FlexFabric 10Gb 2-port 556FLR-SFP+ Adapter</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server\n"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"}],"sw_keys":[{"name":"ocnd65.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLEAHasseFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB012000GWDFE"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Linux (x64) -&nbsp;&nbsp;MB012000GWDFE Drive</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; HPG2</p>\n\n<p><strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"6044724","datemodified":"2021-07-23T07:21:25","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/CP048137.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/HLEAHasseFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP048137.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP048137.scexe"],"md5sum":"48ae07ad5f154813cfd5c73f0f0732dd","name":"firmware-hdd-059b8654a6-HPG3-2.1.x86_64.rpm","release":"2021-07-23T07:09:09","revision":"0","sha1sum":"914964959a7648f7d9554358cc9bf7fa4eb09418","size":"5MB","target_guids":["4d2340a5-3042-3231-3030-304757444645"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"ae7662457b594bb08733bceba6635c72","version":"fa5acad2d85e42cdaefd0f2b69d88fc8"},"installation":{"command":"CP040337.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul>\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh .&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul>\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e </em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul>\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio .rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd--*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd--*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>Online:</strong></p>\n\n<ul>\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p>Follow the instructions on the screen.</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux (x64) - MB012000GWDFEドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"MB012000GWDFE","target_guid":"4d2340a5-3042-3231-3030-304757444645","type":"sata"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-06-26T12:05:09","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<p>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</p>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB012000GWDFE","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TAMG08acHPG3.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG3"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive model: MB016000GWXKK"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp; &nbsp; Online&nbsp;HDD/SSD Flash Component for Windows&nbsp;(x64) - MB016000GWXKK Drive</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;HPG3<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp; None<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"3710568","datemodified":"2021-07-26T16:29:04","file_list":["cp049127.xml","cpqsetup.exe","payload.json","setup.dll","TAMG08acHPG3.REL"],"md5sum":"0b67804894c264bacab9ace90f5e1cbc","name":"cp049127.exe","release":"2021-07-26T16:18:04","revision":"0","sha1sum":"9d750e9fe79ed23f4e863a20ff6bad57a5bca262","size":"3MB","target_guids":["4d2340a5-3042-3631-3030-304757584b4b"],"type_of_change":"1","version":"HPG3"}],"id":{"product":"d05a1433339f497faa2734fb31c015eb","version":"ff851755b36f45b1af25354b0b757c07"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run <em>launch_sum.bat</em> script which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MB016000GWXKK","target_guid":"4d2340a5-3042-3631-3030-304757584b4b","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T16:05:59","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2022.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB016000GWXKK","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the driver for HPE Intel ixn 10 Gigabit Ethernet NICs running under Microsoft Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージは、Microsoft Windows Server 2016で動作しているHPE Intel ixn 10 Gigabit Ethernet NIC用のドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1146488","datemodified":"2021-11-02T08:59:51","file_list":["cp047056.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn65x64.cat","ixn65x64.din","ixn65x64.inf","ixn65x64.sys","ixnmsg.dll","NicCo5.dll","nicdrvr.dll","NicInIXN.dll"],"md5sum":"196c53f3bcd532b32e0d9cb036fd7675","name":"cp047056.exe","release":"2021-11-02T08:45:59","revision":"0","sha1sum":"66c3dfc506bbaa48f03bfc03d4cf2e6369ca66c9","size":"1MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f"],"type_of_change":"0","version":"4.1.239.0"}],"id":{"product":"d7031a8852f2411096f049c632e0a499","version":"520027566f164cd495d018e2e4a08ce6"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.<br><p>From that drive and directory, execute the downloaded file.   <br><p>Click the \"Install\" button to proceed with the installation.<br>"},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。ダウンロードしたファイルは、Smartコンポーネント番号に基づくファイル名を持つ、自己解凍型の実行ファイルです。<br><p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<br><p>［インストール］ボタンをクリックして、インストールを開始します。<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Intel ixn Driver for Windows Server 2016"},{"lang":"ja","x_late":"HPE Intel ixnドライバー for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"400"},"supported_devices":[{"dev":"10FB","subdev":"17D0","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d0","type":"pci","ven":"8086"},{"dev":"10FB","subdev":"17D3","subven":"103C","target_guid":"a6b1a447-382a-5a4f-8086-10fb103c17d3","type":"pci","ven":"8086"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-09T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>This product contains Windows system update supported improvements.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>This product is updated to maintain compatibility with updated Windows installation library NicInIXN.dll and ixnmsg.dll.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U17","value":"HPE ProLiant DL580 Gen9 Server"},{"key":"P86","value":"HPE ProLiant DL120 Gen9 Server"},{"key":"U44","value":"HPE ProLiant ML30 Gen10 Server"},{"key":"U43","value":"HPE ProLiant DL20 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"J10","value":"HP ProLiant ML10 v2 Server"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U13","value":"HPE ProLiant XL230a Gen9 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"P95","value":"HPE ProLiant ML150 Gen9 Server"},{"key":"U13","value":"HPE ProLiant XL250a Gen9 Server"},{"key":"U25","value":"HPE ProLiant XL270d Gen9 Server"},{"key":"P85","value":"HPE ProLiant DL560 Gen9 Server"},{"key":"U23","value":"HPE ProLiant ML30 Gen9 Server"},{"key":"U21","value":"HPE ProLiant XL450 Gen9 Server"},{"key":"","value":"HPE ProLiant MicroServer Gen10 Server"},{"key":"U19","value":"HPE Apollo 4200 Gen9 Server"},{"key":"U22","value":"HPE ProLiant DL20 Gen9 Server"},{"key":"U14","value":"HPE ProLiant XL190r Gen9 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U33","value":"HPE ProLiant ML110 Gen10 Server"},{"key":"U14","value":"HPE ProLiant XL170r Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL360 Gen9 Server"},{"key":"P89","value":"HPE ProLiant DL380 Gen9 Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U15","value":"HPE ProLiant DL60 Gen9 Server"},{"key":"U15","value":"HPE ProLiant DL80 Gen9 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"P99","value":"HPE ProLiant ML110 Gen9 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"P92","value":"HPE ProLiant ML350 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL160 Gen9 Server"},{"key":"U20","value":"HPE ProLiant DL180 Gen9 Server"},{"key":"O42","value":"HP ProLiant ML10 Gen9 Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"U26","value":"HPE ProLiant Thin Micro TM200 Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"},{"key":"U31","value":"HPE ProLiant DL160 Gen10 Server"}],"sw_keys":[{"name":"ixn65x64.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"12.8.528.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"12.8.528.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"12.8.528.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"12.8.528.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P12852821.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"12.8.528.21"}]},"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"],"package":{"category":[{"key":"2900374","languages":[{"lang":"fr","x_late":"Micrologiciel - Stockage Fibre Channel"},{"lang":"en","x_late":"Firmware - Storage Fibre Channel"},{"lang":"cn","x_late":"固件 - 存储光纤通道"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置光纖通道"},{"lang":"de","x_late":"Firmware - Glasfaserspeicher"},{"lang":"ko","x_late":"펌웨어 - 스토리지 파이버 채널"},{"lang":"it","x_late":"Firmware - Memorizzazione Fibre Channel"},{"lang":"ja","x_late":"ファームウェア - ストレージ ファイバ チャネル"},{"lang":"es","x_late":"Firmware - Canal de fibra de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This component upgrades the operating firmware and boot BIOS of Emulex Fibre Channel host bus adapters."},{"lang":"ja","x_late":"このコンポーネントは、EmulexファイバーチャネルホストバスアダプターのオペレーティングファームウェアとブートBIOSをアップグレードします。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[],"files":[{"bytes":"11895566","datemodified":"2021-11-18T12:19:36","file_list":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/CP049956.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/elxflashStandalone-linux-12.8.528.12-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/firmware/B12852821.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/firmware/P12852821.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2022.03.01-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049956.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049956.scexe"],"md5sum":"f5ec7a6c691708a6b3a532c65a8de53e","name":"firmware-fc-emulex-2022.03.01-1.1.x86_64.rpm","release":"2021-11-18T12:05:09","revision":"0","sha1sum":"7705eb9e4d7ae72d97927d367e9248cc4d238800","size":"11MB","target_guids":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"type_of_change":"1","version":"2022.03.01"}],"id":{"product":"ccd2fccdbff94b0ab75d085d46522784","version":"0ee427ec091343ef90af3af195100b10"},"installation":{"command":"installer","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":180,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"1.37","description":"For Gen10 server iLO version 1.37 or greater is required and should be already active"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","DeviceGuid":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","ServerModel":["*"],"Target_guids":[],"Type":"GTE","Version":"2.62","description":"For Gen9 server iLO version 2.62 or greater is required and should be already active"}]}]}]},"installation_notes":[{"lang":"en","x_late":"<p>Firmware installation is a two-step process.&nbsp; Install the firmware installation tool rpm, then execute the installed tool to update the firmware.<br />\n&nbsp;<br />\n&nbsp;1. Install the firmware installation tool:&nbsp; rpm -Uvh &lt;rpm_package_name&gt;.rpm&nbsp; This extracts the firmware installation tool to /usr/lib/x86_64-linux-gnu (64-bit systems) .<br />\n&nbsp;<br />\n&nbsp;2. cd to the appropriate location for your system, and update the firmware by executing ./setup<br />\n&nbsp;<br />\n&nbsp;When the firmware installation completes, you may remove the firmware installation tool from your system using the rpm -e command : rpm -e &lt;rpm_package_name&gt;.</p>\n"},{"lang":"ja","x_late":"<p>ファームウェアインストールは、2段階のプロセスです。  ファームウェアインストールツールrpmをインストールし、ファームウェアをアップデートするため、インストールしたツールを実行します。<br />\n <br />\n 1. ファームウェアインストレーションツール：rpm -Uvh <rpm_package_name>.rpmをインストールします。これにより、ファームウェアインストレーションツールが/usr/lib/x86_64-linux-gnuに抽出されます（64ビットシステム）。<br />\n <br />\n 2. 使用するシステムの適切な場所へcdし、./setupを実行してファームウェアをアップデートします<br />\n <br />\n ファームウェアインストレーションの完了後は、rpm -eコマンド（rpm -e <rpm_package_name>）を使用して、システムからファームウェアインストレーションツールを削除してもかまいません。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)"}],"prerequisites":{"required_diskspace":{"size_kb":"20000"},"supported_devices":[{"dev":"F400","subdev":"0368","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900368","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"0367","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f40015900367","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0214","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900214","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0213","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900213","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0202","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900202","type":"pci","ven":"10DF"},{"dev":"E300","subdev":"0201","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-e30015900201","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D5","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d5","type":"pci","ven":"10DF"},{"dev":"F400","subdev":"02D6","subven":"1590","target_guid":"a6b1a447-382a-5a4f-10df-f400159002d6","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-12-11T07:05:36","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellspacing=\"1\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">64Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p dir=\"LTR\">This Firmware package contains following firmware versions:</p>\n\n<table border=\"1\" cellpadding=\"1\" cellspacing=\"1\" dir=\"LTR\" style=\"width:935px\">\n\t<tbody>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Adapter</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Speed</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Universal Boot Image</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Firmware</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>UEFI</strong></p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\"><strong>Boot Bios</strong></p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">16Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Single Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">HPE SN1610E 32Gb Dual Port Fibre Channel Host Bus Adapter</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">32Gb</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.21</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.528.10</p>\n\t\t\t</td>\n\t\t\t<td style=\"vertical-align:middle\">\n\t\t\t<p dir=\"LTR\">12.8.502.0</p>\n\t\t\t</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb&nbsp;Single Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t\t<tr>\n\t\t\t<td style=\"vertical-align:middle\">HPE&nbsp;SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter</td>\n\t\t\t<td style=\"vertical-align:middle\">64Gb</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.21</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.528.10</td>\n\t\t\t<td style=\"vertical-align:middle\">12.8.502.0</td>\n\t\t</tr>\n\t</tbody>\n</table>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A41","value":"HPE ProLiant DL325 Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL190r Gen10 Server"},{"key":"U38","value":"HPE ProLiant XL170r Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"},{"key":"U41","value":"HPE ProLiant ML350 Gen10 Server"},{"key":"U32","value":"HPE ProLiant DL360 Gen10 Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"","value":"HPE ProLiant DL388 Gen10 Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"","value":"HPE Apollo 2000 Gen10 Plus System"},{"key":"A47","value":"HPE ProLiant XL675d Gen10 Plus Server"},{"key":"U37","value":"HPE ProLiant XL230k Gen10 Server"},{"key":"U36","value":"HPE ProLiant DL120 Gen10 Server"},{"key":"U34","value":"HPE ProLiant DL580 Gen10 Server"},{"key":"U30","value":"HPE ProLiant DL380 Gen10 Server"},{"key":"A48","value":"HPE ProLiant XL645d Gen10 Plus Servers"},{"key":"U34","value":"HPE ProLiant DL560 Gen10 Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"A40","value":"HPE ProLiant DL385 Gen10 Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U31","value":"HPE ProLiant DL180 Gen10 Server"}],"sw_keys":[{"name":"emulex","sw_key_expectedpath":"firmware:emulex"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This component contains the driver for Broadcom NetXtreme-E devices for Windows Server 2016."},{"lang":"ja","x_late":"このコンポーネントパッケージには、Windows Server 2016用Broadcom NetXtreme-Eデバイスのドライバーが含まれています。"}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]},{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"ja","x_late":"ネットワーク"},{"lang":"cn","x_late":"网络"}]}],"documentation":[],"files":[{"bytes":"1017632","datemodified":"2021-01-14T09:17:45","file_list":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp045254.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"529af92643339b8aff039ede88b319cc","name":"cp045254.exe","release":"2021-01-14T09:03:05","revision":"0","sha1sum":"0ab41c01f8b39fde8318f720d1d082b189367a38","size":"0MB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"type_of_change":"0","version":"218.0.32.0"}],"id":{"product":"4db7819f5f294e828ed2663d73c4bc75","version":"ad377dec54a74be9a64df62a6fb23369"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the \"Install\" button to proceed with the installation."},{"lang":"ja","x_late":"Smartコンポーネントをハードディスクドライブにダウンロードし、そのディレクトリに移動します。<p>そのドライブのディレクトリから、ダウンロードしたファイルを実行します。<p>［インストール］ボタンをクリックして、インストールを開始します。"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Broadcom NetXtreme-E Driver for Windows Server 2016"},{"lang":"ja","x_late":"Broadcom NetXtreme-Eドライバーfor Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"600"},"supported_devices":[{"dev":"16D7","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41597","type":"pci","ven":"14E4"},{"dev":"16D7","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d714e41596","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41593","type":"pci","ven":"14E4"},{"dev":"16D8","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d814e41592","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41595","type":"pci","ven":"14E4"},{"dev":"16D6","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16d614e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41593","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41592","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41593","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41592","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"0000","subven":"0000","target_guid":"","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41595","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41594","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41597","type":"pci","ven":"14E4"},{"dev":"16BD","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16bd14e41596","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41595","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41594","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41597","type":"pci","ven":"14E4"},{"dev":"16C5","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c514e41596","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41593","type":"pci","ven":"14E4"},{"dev":"16EE","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ee14e41592","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41593","type":"pci","ven":"14E4"},{"dev":"16EF","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ef14e41592","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41595","type":"pci","ven":"14E4"},{"dev":"16EB","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16eb14e41594","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41597","type":"pci","ven":"14E4"},{"dev":"16ED","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ed14e41596","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41595","type":"pci","ven":"14E4"},{"dev":"16DE","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16de14e41594","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41597","type":"pci","ven":"14E4"},{"dev":"16EC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16ec14e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D8","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d8","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D6","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d6","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"16D7","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e416d7","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41593","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1593","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41593","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1592","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41592","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41595","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41594","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41597","type":"pci","ven":"14E4"},{"dev":"16C1","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16c114e41596","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1595","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41595","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1594","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41594","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1597","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41597","type":"pci","ven":"14E4"},{"dev":"16DC","subdev":"1596","subven":"14E4","target_guid":"a6b1a447-382a-5a4f-14e4-16dc14e41596","type":"pci","ven":"14E4"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-01-12T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"<p>Initial release.</p>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<ul>\n\t<li>This product correct an issue where an system are freeze and reboot when system recovering after non-fatal error.</li>\n\t<li>This product correct an issue which fixes VF will not load on certain Virtual OS when Windows is host OS.&nbsp;</li>\n\t<li>This product correct an issue which fixes user mode RDMA blue screen of death (BSoD) caused by an IRP SystemBuffer access race condition</li>\n\t<li>This product corrects a Windows Stop Error blue screen of death (BSoD) seen when uninstalling the NDIS driver</li>\n</ul>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U56","value":"HPE ProLiant DL110 Gen10 Plus Telco Server"},{"key":"U47","value":"HPE ProLiant XL220n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"U47","value":"HPE Apollo n2800 24SFF Gen10 Plus CTO Chassis"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"U47","value":"HPE ProLiant XL290n Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U50","value":"HPE ProLiant XL420 Gen10 Plus Servers"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"A46","value":"HPE ProLiant XL225n Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"U48","value":"HPE ProLiant MicroServer Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"}],"sw_keys":[{"name":"bnxtnd.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4510 Gen10 Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"Talladega-Release-1.56-build-000.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd180c771051","Version":"1.56"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900214","languages":[{"lang":"fr","x_late":"Micrologiciel - Contrôleur de stockage"},{"lang":"en","x_late":"Firmware - Storage Controller"},{"lang":"cn","x_late":"固件 - 存储控制器"},{"lang":"tw","x_late":"韌體 ─ 儲存裝置控制器"},{"lang":"de","x_late":"Firmware - Speichercontroller"},{"lang":"ko","x_late":"펌웨어 - 스토리지 컨트롤러"},{"lang":"it","x_late":"Firmware - Controller di memorizzazione"},{"lang":"ja","x_late":"ファームウェア - ストレージ コントローラ"},{"lang":"es","x_late":"Firmware - Controlador de almacenamiento"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the HPE Apollo 45xx Gen10 Backplane Expanders"},{"lang":"ja","x_late":"このSmartコンポーネントは、HPE Apollo 45xx Gen10バックプレーンエキスパンダーのファームウェアを提供します"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; Online ROM Flash Component for Windows &ndash; HPE Apollo 45xx Gen10&nbsp;Backplane Expander Firmware</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp; &nbsp; &nbsp;1.56(C)<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;1.00<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added HPE Smart Array p824i-p controller support</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"5731776","datemodified":"2018-12-12T14:04:04","file_list":["cp037765.xml","cpqsetup.exe","flash_Exp_1.00.bat","payload.json","setup.bat","setup.dll","storcli64.exe","Talladega-Release-1.56-build-000.bin"],"md5sum":"143ec9be382ba3121af59a7bd7c0cbfd","name":"cp037765.exe","release":"2018-12-12T19:56:04","revision":"0","sha1sum":"1323db26a9c8351b8b23825c5e577fe5915fb5c8","size":"5MB","target_guids":["b99dfb74-f0bc-464f-b418-cd180c771051"],"type_of_change":"0","version":"1.56"}],"id":{"product":"466714784bac4803a010a4a944178d10","version":"597ef8fdd0c9438da8f7c1eb7edfbc73"},"installation":{"command":"setup.bat","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後必須重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅해야 합니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要です。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"yes"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Reboot your system if you would like the update to take effect immediately.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a></strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\SPP20xxxxx\\packages</li>\n\t<li>Run launch_sum.bat script which is found in the root of the ISO</li>\n\t<li>Follow the instructions on the screen</li>\n</ul>\n\n<p>&nbsp;</p>\n\n<p>&nbsp;</p>\n"},{"lang":"ja","x_late":"<p><strong>ターゲットサーバー上のWindowsオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>Smartコンポーネントを一時ディレクトリに置きます。</li>\n\t<li>Smartコンポーネントをダブルクリックします。</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>アップデートをすぐに適用したい場合は、ご使用のシステムを再起動してください。</li>\n</ul>\n\n<p><strong>HP Smart Update Managerを使用するには、\n          </strong><strong><a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant:</a>から以下の手順に従ってください</strong></p>\n\n<ul>\n\t<li>ディレクトリ\\SPP20xxxxx\\hp\\swpackagesにアップデートに必要なファームウェアをコピーします。</li>\n\t<li>ISOのルートにある launch_hpsum.bat スクリプトを実行します。</li>\n\t<li>画面の指示に従います。</li>\n</ul>\n\n<p> </p>\n\n<p> </p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online ROM Flash Component for Windows (x64) - HPE Apollo 45xx Gen10 Backplane Expander Firmware "},{"lang":"ja","x_late":"オンラインROMフラッシュコンポーネント for Windows (x64) - HPE Apollo 45xx Gen10バックプレーンエキスパンダーファームウェア "}],"prerequisites":{"required_diskspace":{"size_kb":"15000"},"supported_devices":[{"id":"Apollo 4510Gen10","target_guid":"","type":"agp"}],"supported_operating_systems":[{"major":"6","minor":"3","name":"Microsoft Windows Server 2012 R2","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":true},"release_date":"2018-11-03T16:51:25","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Windows Server 2019 OS</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added HPE Smart Array p824i-p controller support</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"U40","value":"HPE Apollo 4510 System"},{"key":"U40","value":"HPE ProLiant XL450 Gen10 Server"}],"sw_keys":[{"name":"Apollo 4510Gen10","sw_key_expectedpath":"firmware:sd:sasexpander"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Type":"Software","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"11300095","languages":[{"lang":"fr","x_late":"Pilote - Réseau"},{"lang":"en","x_late":"Driver - Network"},{"lang":"cn","x_late":"驱动程序 - 网络"},{"lang":"tw","x_late":"驅動程式 ─ 網路"},{"lang":"de","x_late":"Treiber - Netzwerk"},{"lang":"ko","x_late":"드라이버 – 네트워크"},{"lang":"it","x_late":"Driver - Rete"},{"lang":"ja","x_late":"ドライバ - ネットワーク"},{"lang":"es","x_late":"Controlador - Red"}]}],"description":[{"lang":"en","x_late":"This Component Package contains the iSCSI driver for the HPE Blade Emulex 10/20Gb Server Adapters for Windows Server 2016."}],"divisions":[{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"cn","x_late":"服务器"},{"lang":"ja","x_late":"サーバ"}]},{"key":"65","language":[{"lang":"tw","x_late":"網路"},{"lang":"en","x_late":"Networking"},{"lang":"ko","x_late":"네트워킹"},{"lang":"cn","x_late":"网络"},{"lang":"ja","x_late":"ネットワーク"}]}],"documentation":[],"files":[{"bytes":"914144","datemodified":"2019-10-24T22:59:11","file_list":["be2iscsi.cat","be2iscsi.inf","be2iscsi.sys","bepiscsi.dll","cp039931.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"md5sum":"746411ce6afcc96d398b2e6a03c2d62c","name":"cp039931.exe","release":"2019-10-24T21:44:03","revision":"0","sha1sum":"d8ae6b9adf201fbafe1672a6b0dea792c36bc509","size":"892KB","target_guids":["20a6e8e4-bf33-4c71-a6bf-d9ec037c8524"],"type_of_change":"0","version":"12.0.1171.0"}],"id":{"product":"9017d5d393b24dab905e04b38c0d82f3","version":"e176eabb9c134c88ae1e0d1f591d5735"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":0,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後無需重新啟動，更新就會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot is not required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"설치 후 재부팅하지 않아도 업데이트가 적용되고 하드웨어 안정성이 유지됩니다."},{"lang":"cn","x_late":"安装之后无需重启即可使更新生效并可保持硬件稳定性。"},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後の再起動は必要ありません。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"Download the Smart Component to a directory on your hard drive and change to that directory.<p>From that drive and directory, execute the downloaded file.<p>Click the Install button to proceed with the installation.<br>"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"HPE Blade Emulex 10/20GbE iSCSI Driver for Windows Server 2016"}],"prerequisites":{"required_diskspace":{"size_kb":"320"},"supported_devices":[{"dev":"0722","subdev":"1935","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1935","type":"pci","ven":"10DF"},{"dev":"0722","subdev":"1934","subven":"103C","target_guid":"a6b1a447-382a-5a4f-10df-0722103c1934","type":"pci","ven":"10DF"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2019-11-08T00:00:00","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<p>Initial release.</p>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"I38","value":"HPE ProLiant BL660c Gen9 Server"},{"key":"I41","value":"HPE ProLiant BL460c Gen10 Server"},{"key":"I36","value":"HPE ProLiant BL460c Gen9 Server"}],"sw_keys":[{"name":"be2iscsi.sys","sw_key_expectedpath":"%systemroot%\\system32\\drivers"}],"upgrade_requirements":"Optional"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWAYK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a5741594b","Version":"HPD6"},{"DeviceName":"MB008000JWAYH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"HLIBRHsseFD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57415948","Version":"HPD6"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This Smart Component provides firmware for the following drive models: MB010000JWAYK and MB008000JWAYH"},{"lang":"ja","x_late":"このSmartコンポーネントが、ファームウェアを提供できるドライブモデル： MB010000JWAYKおよびMB008000JWAYH"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp; &nbsp;&nbsp; Online&nbsp;HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives<br />\n<br />\n<strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD6<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD5<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n&nbsp;</p>\n\n<p><strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n\n<p>&nbsp;</p>\n"}],"files":[{"bytes":"18601443","datemodified":"2021-08-26T12:47:37","file_list":["/CP048334_BUILD_2.data","/CP048334.vmexe","/CP048334.vmexe64","/CP048334.vmfile","/CP048334_VMw.zip","/CP048334.xml","/payload.json","/CP048334_VMw.zip/index.xml","/CP048334_VMw.zip/vendor-index.xml","/CP048334_VMw.zip/metadata.zip","/CP048334_VMw.zip/vib20/CP048334/HPE_bootbank_CP048334_HPD6.2-7.0.0.15843807.vib","/CP048334_VMw.zip/metadata.zip/vendor-index.xml","/CP048334_VMw.zip/metadata.zip/vmware.xml","/CP048334_VMw.zip/metadata.zip/vibs/CP048334-5781854618042290416.xml","/CP048334_VMw.zip/metadata.zip/bulletins/Smart-Component-CP048334_HPD6.2-7.0.0.15843807.xml"],"md5sum":"6b452ad211cb63153a35a062a581697a","name":"CP048334.zip","release":"2021-08-26T12:42:10","revision":"0","sha1sum":"c8b40ab61dbad03e50e69bc5261b1aa5856f31d2","size":"17MB","target_guids":["4d2340a5-3042-3031-3030-304a5741594b","4d2340a5-3042-3830-3030-304a57415948"],"type_of_change":"1","version":"HPD6","vib_list":[{"name":"CP048334","version":"HPD6.2-7.0.0.15843807"}]}],"id":{"product":"58002f5fbb3c4bdca0598c03bb921813","version":"c86b80c8d73b4e7cbfcdeff981153ae7"},"installation":{"command":"CP040637.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use Smart Update Manager from the Service Pack for ProLiant:<br />\n<br />\n&nbsp;&nbsp;&nbsp;&nbsp; Offline (</strong>The SPP Offline mode boots a special Linux OS environment, thus the Linux Smart Components are used, not the VMware Smart Components<strong>):</strong></p>\n\n<ul>\n\t<li>Place the&nbsp;<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant&nbsp;</a>on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired Linux firmware component to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for ProLiant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p><strong>&nbsp;&nbsp;&nbsp;&nbsp; Remote Online:</strong></p>\n\n<ul>\n\t<li>Download the appropriate SPP.</li>\n\t<li>Add the component to the SPP.</li>\n\t<li>Mount the SPP on a remote server running Windows or Linux that has a network connection to the ESXi host to be updated.</li>\n\t<li>Run SUM.</li>\n\t<li>Add the ESXi host to be updated as a remote target/node.</li>\n\t<li>Enter IP or DNS address of the ESXi host to be updated Enter the ESXi host credentials (root or administrator username and password).</li>\n\t<li><strong>For SUM 6.0 and newer</strong>, select both the Additional Package with the added component and the SPP Baseline on the node Inventory page.</li>\n\t<li>Follow Smart Update Manager Steps and complete the firmware update.</li>\n</ul>\n\n<p>Refer to the SPP documentation for detailed instructions at:&nbsp;<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Enable Tech Support Mode on the ESXi host.</li>\n\t<li>Login as root. (You must be root in order to apply the update.)</li>\n\t<li>Place the Smart Component zip file in a temporary directory.</li>\n\t<li>Unzip the file CPxxxxxx.zip</li>\n\t<li>Ensure that CPxxxxxx.vmexe (ESXi 6.7 &amp; Prior Versions) &nbsp;and CPxxxxxx.vmexe64 (ESXi 7.0) is executable by using the command:</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;chmod +x CPxxxxxx.vmexe&nbsp;&nbsp;&nbsp;&nbsp;(or)&nbsp;&nbsp;&nbsp; chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>From the same directory, execute the Smart Component. For example: ./CPxxxxxx.vmexe&nbsp; (or)&nbsp; ./CPxxxxxx.vmexe64</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">&nbsp;</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Additional information to execute VIB file.</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip&nbsp; or esxcli software component apply --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip (if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component with command set options -s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;or esxcli software vib install --no-sig-check &ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip &nbsp;(if vib file is unsigned)</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component&rdquo; with command set options &ldquo;-s, -f, -e, -g etc. if required.</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">full path is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>Smart Update Managerを使用するには、Service Pack for ProLiantから以下の手順に従ってください:<br />\n<br />\n     オフライン(</strong>SPPオフラインモードは特別なLinux OS環境を起動します。したがって、VMware Smartコンポーネントではなく、Linux Smartコンポーネントが使用されます<strong>):</strong></p>\n\n<ul>\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\">USB Key Utility for Windows</a>を使用して、<a href=\"http://www.hpe.com/info/spp\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートに必要なLinuxファームウェアコンポーネントをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p><strong>     リモートオンライン:</strong></p>\n\n<ul>\n\t<li>適切なSPPをダウンロードします。</li>\n\t<li>SPPにコンポーネントを追加しました。</li>\n\t<li>アップデート対象のESXiホストへのネットワーク接続を持つWindowsまたはLinuxを実行しているリモートサーバー上でSPPをマウントします。</li>\n\t<li>SUMを実行します。</li>\n\t<li>リモートターゲット/ノードとしてアップデート対象のESXiホストを追加します。</li>\n\t<li>アップデート対象のESXiホストのIPまたはDNSアドレスを入力します。ESXiホスト認証情報(rootまたは管理者ユーザー名およびパスワード)を入力します。</li>\n\t<li><strong>SUM 6.0以降の場合は</strong>、ノードインベントリページで追加されたコンポーネントおよびSPPベースラインの両方の追加パッケージを選択します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p>詳細な手順については、以下にアクセスしてSPPドキュメントを参照してください:<a href=\"http://www.hpe.com/info/spp/documentation\">http://www.hpe.com/info/spp/documentation</a><br />\n </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。(アップデートを適用するにはrootとしてログインする必要があります。)</li>\n\t<li>Smartコンポーネントzipファイルを一時ディレクトリに置きます。</li>\n\t<li>CPxxxxxx.zipファイルをunzipします</li>\n\t<li>CPxxxxxx.vmexe（ESXi 6.7 &以前のバージョン）およびCPxxxxxx.vmexe64（ESXi 7.0）は、次のコマンドを使用して実行可能です。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">             chmod +x CPxxxxxx.vmexe    または    chmod +x CPxxxxxx.vmexe64</p>\n\n<ul style=\"list-style-type:square\">\n\t<li>同じディレクトリからSmartコンポーネントを実行します。例:  ./CPxxxxxx.vmexe(または)./CPxxxxxx.vmexe64</li>\n\t<li>Smartコンポーネントの指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"> </p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software component apply --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip (vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行: 必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>vibファイルのインストール:esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zipまたはesxcli software vib install --no-sig-check –d <フルパス>/CPxxxxxx_VMw.zip(vibファイルが署名されていない場合)</li>\n\t<li>パス“/opt/Smart_Component/CPxxxxxx”からのバイナリの実行：必要に応じて、コマンドセットオプション-s、-f、-e、-gなどを指定した./Execute_Component。</li>\n\t<li>vibファイルの削除:esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">フルパスは、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for VMware ESXi - MB010000JWAYK and MB008000JWAYH Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor VMware ESXi - MB010000JWAYKおよびMB008000JWAYHドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"6000"},"supported_devices":[{"id":"MB010000JWAYK","target_guid":"4d2340a5-3042-3031-3030-304a5741594b","type":"sas"},{"id":"MB008000JWAYH","target_guid":"4d2340a5-3042-3830-3030-304a57415948","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-07-05T19:44:39","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Reliability enhancements and VENDOR IDENTIFICATION field change from &ldquo;HP&rdquo; to HPE&rdquo;.</li>\n</ul>\n"},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for VMware 7.0 U3</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MB008000JWAYH","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"MB010000JWAYK","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"Gen10Plus_UBM3_Backplane_PIC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"UBM3_V1.24.hex.fw","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd181e51629e","Version":"1.24"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900027","languages":[{"lang":"tw","x_late":"韌體 ─ 系統"},{"lang":"en","x_late":"Firmware - System"},{"lang":"ko","x_late":"펌웨어 - 시스템"},{"lang":"ja","x_late":"ファームウェア - システム"},{"lang":"cn","x_late":"固件 - 系统 ROM"}]}],"description":[{"lang":"en","x_late":"This component updates the firmware on ProLiant Gen10Plus UBM3 storage backplanes."},{"lang":"ja","x_late":"このコンポーネントは、ProLiant Gen10Plus UBM3ストレージバックプレーンをアップデートします。"}],"divisions":[{"key":"68","language":[{"lang":"en","x_late":"ServerOptions"},{"lang":"ko","x_late":"서버 옵션"},{"lang":"ja","x_late":"サーバ オプション"},{"lang":"cn","x_late":"服务器选项"}]},{"key":"6","language":[{"lang":"tw","x_late":"伺服器"},{"lang":"en","x_late":"Server"},{"lang":"ko","x_late":"서버"},{"lang":"ja","x_late":"サーバ"},{"lang":"cn","x_late":"服务器"}]}],"documentation":[],"files":[{"bytes":"14024321","datemodified":"2022-01-17T16:18:40","file_list":["/CP050751_BUILD_6.data","/CP050751.vmexe","/CP050751.vmexe64","/CP050751.vmfile","/CP050751_VMw.zip","/CP050751.xml","/payload.json","/CP050751_VMw.zip/index.xml","/CP050751_VMw.zip/vendor-index.xml","/CP050751_VMw.zip/metadata.zip","/CP050751_VMw.zip/vib20/CP050751/HPE_bootbank_CP050751_1.24.6-7.0.0.15843807.vib","/CP050751_VMw.zip/metadata.zip/vendor-index.xml","/CP050751_VMw.zip/metadata.zip/vmware.xml","/CP050751_VMw.zip/metadata.zip/vibs/CP050751-8128165463961199537.xml","/CP050751_VMw.zip/metadata.zip/bulletins/Smart-Component-CP050751_1.24.6-7.0.0.15843807.xml"],"md5sum":"e721b4da316dd83319c9ada1bf447d64","name":"CP050751.zip","release":"2022-01-17T16:07:05","revision":"0","sha1sum":"97c5891ba507187f85c7b21d559ea7b234d1f1a9","size":"13MB","target_guids":["b99dfb74-f0bc-464f-b418-cd181e51629e"],"type_of_change":"1","version":"1.24","vib_list":[{"name":"CP050751","version":"1.24.6-7.0.0.15843807"}]}],"id":{"product":"0720b596fe34472ebce943ceb259ae5a","version":"2e459fb1212c4818a3828db773814fcc"},"installation":{"command":"CP050751.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":300,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後不一定要重新啟動。更新會在重新啟動後生效。無需重新啟動，就會維持硬體穩定。"},{"lang":"en","x_late":"Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot."},{"lang":"ko","x_late":"재부팅은 설치 후 선택 사항입니다. 업데이트는 재부팅 후 적용됩니다. 하드웨어 안정성은 재부팅하지 않아도 유지됩니다."},{"lang":"ja","x_late":"インストール後の再起動はオプションです。 アップデートは再起動後に有効になります。 ハードウェアの安定は、再起動しなくても維持されます。"},{"lang":"cn","x_late":"安装后重启是可选操作。更新将在重启后生效。无需重启即可保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To use HPE&nbsp;Insight Control for vCenter :</strong></p>\n\n<ul>\n\t<li>Log in to the vSphere Client</li>\n\t<li>Select a server or cluster in the inventory tree</li>\n\t<li>Click the HPE Insight Management tab</li>\n\t<li>Follow Insight Control for vCenter steps to update firmware using a Smart Component</li>\n</ul>\n\n<p><strong>To update firmware from VMware ESXi operating system on target server:</strong></p>\n\n<ul>\n\t<li>Enable Tech Support Mode on the ESXi host</li>\n\t<li>Login as root. (You must be root in order to apply the update)</li>\n\t<li>Place the Smart Component zip file in a temporary directory</li>\n\t<li>Unzip the file CPXXXXXX.zip</li>\n\t<li>Follow the directions mentioned in the Additional Information.</li>\n\t<li>Logout</li>\n\t<li>Disable Tech Support Mode on the ESXi host</li>\n</ul>\n\n<p><strong>Additional information to execute VIB file.</strong></p>\n\n<p><u>Commands required to execute VIB file on ESXi 7.0</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software component apply &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./Execute_Component&nbsp;</li>\n\t<li>Removing vib file : esxcli software component remove &ndash;n Smart-Component-CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>Commands required to execute VIB file on ESXi 6. 7 and prior versions.</u></p>\n\n<ul>\n\t<li>Installing vib file : esxcli software vib install &nbsp;&ndash;d &lt;full path&gt;/CPxxxxxx_VMw.zip.</li>\n\t<li>Executing the binary from path &ldquo;/opt/Smart_Component/CPxxxxxx&rdquo; : ./ Execute_Component</li>\n\t<li>Removing vib file : esxcli software vib remove &ndash;n CPxxxxxx</li>\n\t<li>After removing the vib, we need to manually remove the folders using : rm &ndash;rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p>&lt;full path&gt; is the temporary directory path where zip file was unpacked CPxxxxxx.zip</p>\n"},{"lang":"ja","x_late":"<p><strong>HPE Insight Control for vCenterを使用するには、以下の手順に従ってください：</strong></p>\n\n<ul>\n\t<li>vSphereクライアントにログインします。</li>\n\t<li>インベントリツリーのサーバーまたはクラスターを選択します。</li>\n\t<li>HPE Insight Managementタブをクリックします</li>\n\t<li>HP Insight Control for VMware vCenterの指示に従ってSmartコンポーネントを使いファームウェアのアップデートを行います</li>\n</ul>\n\n<p><strong>ターゲットサーバー上のVMware ESXiオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<ul>\n\t<li>ESXiホスト上のTech Support Modeを有効にします。</li>\n\t<li>rootとしてログインします。（アップデートを適用するにはrootとしてログインする必要があります）</li>\n\t<li>Smartコンポーネントzipファイルをテンポラリディレクトリに置きます。</li>\n\t<li>CPXXXXXX.zipファイルをunzipします</li>\n\t<li>「追加情報」に記載されている指示に従います。</li>\n\t<li>ログアウトします。</li>\n\t<li>ESXiホスト上のTech Support Modeを無効にします</li>\n</ul>\n\n<p><strong>VIBファイルを実行するための追加情報。</strong></p>\n\n<p><u>ESXi 7.0でVIBファイルを実行するために必要なコマンド</u></p>\n\n<ul>\n\t<li>vibファイルのインストール：esxcli software component apply  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./Execute_Component </li>\n\t<li>vibファイルの削除：esxcli software component remove –n Smart-Component-CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><u>ESXi 6. 7以前のバージョンでVIBファイルを実行するために必要なコマンド。</u></p>\n\n<ul>\n\t<li>vibファイルの削除: esxcli software vib install  –d <フルパス>/CPxxxxxx_VMw.zip。</li>\n\t<li>パス\"/opt/Smart_Component/CPxxxxxx\"からのバイナリの実行：./ Execute_Component</li>\n\t<li>vibファイルの削除：esxcli software vib remove –n CPxxxxxx</li>\n\t<li>vibを削除した後、次のコマンドを使用して手動でフォルダーを削除する必要があります：rm –rf /opt/Smart_Component/CPxxxxxx</li>\n</ul>\n\n<p><フルパス>は、zipファイル（CPxxxxxx.zip）が解凍された一時ディレクトリパスです</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online Flash Component for VMware Esxi - Gen10Plus UBM3 Backplane PIC Firmware"},{"lang":"ja","x_late":"オンラインフラッシュコンポーネントfor VMware Esxi - Gen10Plus UBM3バックプレーンPICファームウェア"}],"prerequisites":{"required_diskspace":{"size_kb":"12000"},"supported_devices":[{"id":"9675b54e-1c96-44c3-a7a1-901503000000","target_guid":"","type":"nvmeubmpic"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"VMware ESXi 7.0","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"7","name":"VMware vSphere 6.7","platform":"vmware_esx_server","sr":"OEM"},{"major":"6","minor":"5","name":"VMware vSphere 6.5","platform":"vmware_esx_server","sr":"OEM"}],"supported_platforms":true},"release_date":"2022-02-07T10:27:22","revision_history":[{"lang":"en","latest_enhancements_x_late":"","latest_fixes_x_late":"<ul>\n\t<li>Update device guid</li>\n\t<li>Fixed FW update causing NVME drive missing</li>\n</ul>\n"},{"curr_enhancements_x_late":"","curr_fixes_x_late":"<p>Fix issues</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus v2 Server"},{"key":"A43","value":"HPE ProLiant DL345 Gen10 Plus Server"},{"key":"A43","value":"HPE ProLiant DL325 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus v2 Server"},{"key":"A42","value":"HPE ProLiant DL365 Gen10 Plus Server"},{"key":"U50","value":"HPE Apollo 4200 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL380 Gen10 Plus Server"},{"key":"U46","value":"HPE ProLiant DL360 Gen10 Plus Server"},{"key":"A42","value":"HPE ProLiant DL385 Gen10 Plus Server"},{"key":"02020001","value":"HPE Superdome Flex 280"}],"sw_keys":[{"name":"UBM3","sw_key_expectedpath":"firmware:sd:disk_enclosure"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD7"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD7"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"TA14SXn0HPD7.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD7"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900260","languages":[{"lang":"tw","x_late":"韌體 ─ SAS 儲存磁碟"},{"lang":"en","x_late":"Firmware - SAS Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SAS 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SASストレージ ディスク"},{"lang":"cn","x_late":"固件 - SAS 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: EH000900JWHPP, EH000600JWHPN and EH000300JWHPL"},{"lang":"ja","x_late":"このx64 Smartコンポーネントが、ファームウェアを提供できるドライブモデル: EH000900JWHPP、EH000600JWHPN および EH000300JWHPL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Online&nbsp;HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives</p>\n\n<p><strong>Release Version and/or Date:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD7<br />\n<br />\n<strong>Last Recommended or Critical Version:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Previous Version of Firmware:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; HPD4<br />\n<br />\n<strong>Firmware Dependency:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None<br />\n<br />\n<strong>Enhancements/New Features:</strong></p>\n\n<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<p>&nbsp; &nbsp; &nbsp;None</p>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp; None</p>\n"}],"files":[{"bytes":"4858372","datemodified":"2021-07-26T18:20:20","file_list":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/CP049137.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/TA14SXn0HPD7.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD7-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP049137.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP049137.scexe"],"md5sum":"0d09024de23d1cda500736d939e63a87","name":"firmware-hdd-8d68452816-HPD7-2.1.x86_64.rpm","release":"2021-07-26T18:07:04","revision":"0","sha1sum":"7d7717d64db5c4d3725420259aa6e0874f7ed7dd","size":"4MB","target_guids":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"type_of_change":"1","version":"HPD7"}],"id":{"product":"6f10e85c0a8e4d0f99dcb8584f535fd3","version":"7f6005e31aa240b688679bd7c5e9b51d"},"installation":{"command":"CP041672.scexe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To update firmware from Linux operating system on target server:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware by installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Install the firmware rpm using the command:&nbsp;&nbsp;<em>rpm -ivh &lt;rpm_filename&gt;.&nbsp;</em>&nbsp;This extracts the contents of the rpm&nbsp;to the &#39;/usr/lib/x86_64-linux-gnu&#39; location.</li>\n\t<li>The CP&lt;nnnnnn&gt;.scexe script is located in the &#39;scexe-compat&#39; folder. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the&nbsp;rpm installed in the first step above. &nbsp;</li>\n\t<li>To install firmware, you can execute&nbsp;<strong>ONE</strong>&nbsp;of the following commands:\n\t<ul style=\"list-style-type:square\">\n\t\t<li>./CP&lt;nnnnnn&gt;.scexe in the &#39;/usr/lib/x86_64-linux-gnu/scexe-compat&#39; location (OR)</li>\n\t\t<li><em>./setup</em>&nbsp;in the &#39;/usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location</li>\n\t</ul>\n\t</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n\t<li>To uninstall the rpm, run the command:&nbsp;<em>rpm -e &lt;rpm_package_name&gt;</em>, which is the rpm filename without the &#39;.rpm&#39; extension.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Updating firmware without installing the rpm:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Extract the contents of the rpm using the command:&nbsp;<em>rpm2cpio &lt;rpm_filename&gt;.rpm | cpio -id.&nbsp;</em>&nbsp;This extracts the contents of the rpm to &#39;usr&#39; folder in the current directory.</li>\n\t<li>Navigate to the&nbsp;&#39;usr/lib/x86_64-linux-gnu/firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; location and run&nbsp;<em>./setup</em>&nbsp;to update the firmware. The actual name of the &#39;firmware-hdd-&lt;xxxxxxxxxx&gt;-*&#39; folder is based on the version of the rpm installed in the step above.</li>\n\t<li>The results of the firmware upgrade are saved to the Component.log file, located in the /var/cpq/ directory.</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>Additional Information:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">Installing the firmware rpm package (rpm -ivh) does not update the firmware.&nbsp;&nbsp;It merely extracts the rpm content to the local system. Updating the firmware on the local system requires following the&nbsp;above outlined steps.</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>To use Smart Update Manager from the Service Pack for ProLiant:</strong><br />\n<br />\n<strong>Offline:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Place the&nbsp;<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant</a>&nbsp;on a USB key using the&nbsp;<a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>.</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages on the USB key.</li>\n\t<li>Boot from the newly created Service Pack for Proliant USB key.</li>\n\t<li>Follow Smart Update Manager steps to complete firmware update.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Online:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>Login as root. (You must be root in order to apply the ROM update.)</li>\n\t<li>Place the desired firmware to be updated in the directory, /packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.sh</em>&nbsp;script which is found in the root of the ISO.</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">Follow the instructions on the screen.</p>\n"},{"lang":"ja","x_late":"<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>ターゲットサーバー上のLinuxオペレーティングシステムからファームウェアをアップデートするには、以下の手順に従ってください。</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールによりファームウェアをアップデート：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>コマンド <em>rpm -ivh <rpm_filename>を使用して、ファームウェアrpmをインストールします： </em> これは、'/usr/lib/x86_64-linux-gnu'へrpmの内容をを抽出します。</li>\n\t<li>CP<nnnnnn>.scexeスクリプトは、scexe-compatフォルダーにあります。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記の最初のステップでインストールされるrpmのバージョンに基づきます。 </li>\n\t<li>ファームウェアをインストールするために、以下のコマンドの<strong>1つ</strong>を実行することができます：\n\t<ul style=\"list-style-type:square\">\n\t\t<li>'/usr/lib/x86_64-linux-gnu/scexe-compat'で、./CP<nnnnnn>.scexe（または）</li>\n\t\t<li>'/usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*'で、<em>./setup</em></li>\n\t</ul>\n\t</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n\t<li>rpmをアンインストールするには、コマンド:<em>rpm -e <rpm_package_name></em>(.rpm拡張子の付いていないrpmファイル名)を実行します。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>rpmのインストールなしでのファームウェアのアップデート:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rpmの内容をを次のコマンドを用いて抽出します。<em>rpm2cpio <rpm_filename>.rpm | cpio -id </em> これは、現在のディレクトリの'usr'フォルダーへrpmの内容をを抽出します。</li>\n\t<li>usr/lib/x86_64-linux-gnu/firmware-hdd-<xxxxxxxxxx>-*ロケーションに移動し、<em>./setup</em>を実行してファームウェアをアップデートします。firmware-hdd-<xxxxxxxxxx>-*フォルダーの実際の名前は、上記のステップでインストールされるrpmのバージョンに基づきます。</li>\n\t<li>ファームウェアアップグレードの結果は、/var/cpq/ディレクトリにあるComponent.logファイルに保存されます。</li>\n</ul>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\"><strong>追加情報:</strong></p>\n\n<p style=\"margin-left:30pt; margin-right:0px; text-align:left\">ファームウェアrpmパッケージのインストール（rpm -ivh）は、ファームウェアをアップデートしません。  単に、ローカルシステムへのrpmの内容をを抽出するだけです。ローカルシステムのファームウェアをアップデートするには、上記の手順に従う必要があります。</p>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>Smart Update Managerを使用するにはService Pack for ProLiantから以下の手順に従ってください：</strong><br />\n<br />\n<strong>オフライン:</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li><a href=\"http://h20564.www2.hpe.com/hpsc/swd/public/readIndex?sp4ts.oid=1008862658\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">USB Key Utility for Windows</a>を使用して、<a href=\"https://www.hpe.com/servers/spp/download\" style=\"color: rgb(0, 0, 255); text-decoration: none;\">Service Pack for ProLiant </a>をUSBキーにコピーします。</li>\n\t<li>アップデートするファームウェアをUSBキーの/packagesディレクトリにコピーします。</li>\n\t<li>新たに作成したService Pack for ProLiant USBキーから起動します。</li>\n\t<li>Smart Update Managerの指示に従ってファームウェアのアップデートを行います。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\"><strong>オンライン：</strong></p>\n\n<ul style=\"list-style-type:square\">\n\t<li>rootとしてログインします。(ROMアップデートを適用するにはrootとしてログインする必要があります) </li>\n\t<li>アップデートするファームウェアを/packagesディレクトリにコピーします。</li>\n\t<li>ISOのルートにある<em>launch_sum.sh</em>スクリプトを実行します。</li>\n</ul>\n\n<p style=\"margin-left:0px; margin-right:0px; text-align:left\">画面の指示に従います。</p>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネントfor Linux(x64) - EH000900JWHPP、EH000600JWHPNおよびEH000300JWHPLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"4000"},"supported_devices":[{"id":"EH000300JWHPL","target_guid":"452340a5-3048-3030-3330-304a5748504c","type":"sas"},{"id":"EH000600JWHPN","target_guid":"452340a5-3048-3030-3630-304a5748504e","type":"sas"},{"id":"EH000900JWHPP","target_guid":"452340a5-3048-3030-3930-304a57485050","type":"sas"}],"supported_operating_systems":[{"major":"7","minor":"0","name":"Red Hat Enterprise Linux 7 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"},{"major":"12","minor":"0","name":"SUSE Linux Enterprise Server 12","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"15","minor":"0","name":"SUSE Linux Enterprise Server 15","platform":"suse_linux_enterprise_server_x86_64","sr":"OEM"},{"major":"8","minor":"0","name":"Red Hat Enterprise Linux 8 Server","platform":"red_hat_enterprise_linux_x86_64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-08-26T18:03:30","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.3</li>\n</ul>\n","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for RHEL 8.4 and SLES15SP3.</li>\n</ul>\n","curr_fixes_x_late":"","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"EH000900JWHPP","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000300JWHPL","sw_key_expectedpath":"firmware:sd:SAS"},{"name":"EH000600JWHPN","sw_key_expectedpath":"firmware:sd:SAS"}],"upgrade_requirements":"Recommended"}},{"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG2"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG2"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG2"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOk":false,"FileName":"K503HPG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UefiFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG2"}]},"Type":"Firmware","UpdatableBy":["RuntimeAgent"],"package":{"category":[{"key":"2900324","languages":[{"lang":"tw","x_late":"韌體 ─ SATA 儲存磁碟"},{"lang":"en","x_late":"Firmware - SATA Storage Disk"},{"lang":"ko","x_late":"펌웨어 - SATA 스토리지 디스크"},{"lang":"ja","x_late":"ファームウェア - SATAストレージ ディスク"},{"lang":"cn","x_late":"固件 - SATA 存储磁盘"}]}],"description":[{"lang":"en","x_late":"This x64 Smart Component provides firmware for the following drive models: MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL"},{"lang":"ja","x_late":"このx64Smartコンポーネントが、ファームウェアを提供できるドライブモデル: MK000480GWXFF、MK000960GWXFH、MK001920GWXFK、およびMK003840GWXFL"}],"divisions":[{"key":"9","language":[{"lang":"tw","x_late":"儲存裝置"},{"lang":"en","x_late":"Storage"},{"lang":"ko","x_late":"스토리지"},{"lang":"ja","x_late":"ストレージ"},{"lang":"cn","x_late":"存储设备"}]}],"documentation":[{"lang":"en","x_late":"<p><strong>Deliverable Name:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>Online&nbsp;HDD/SSD Flash Component for Windows (x64)&nbsp;- MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives</p>\n\n<p><strong>Release Version and/or Date:<br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</strong>HPG2</p>\n\n<p><strong>Last Recommended or Critical Version:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1</p>\n\n<p><strong>Previous Version of Firmware:</strong><br />\n&nbsp; &nbsp; &nbsp;HPG1<br />\n<strong>Firmware Dependency:&nbsp;&nbsp;</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None&nbsp;<strong>&nbsp;</strong></p>\n\n<p><strong>Enhancements/New Features :</strong></p>\n\n<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n\n<p><strong>Problems Fixed:</strong></p>\n\n<ul>\n\t<li>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</li>\n</ul>\n\n<p><strong>Known Issues:</strong><br />\n&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;None</p>\n"}],"files":[{"bytes":"7426344","datemodified":"2021-08-17T11:17:47","file_list":["cp049300.xml","cpqsetup.exe","K503HPG2.rel","payload.json","setup.dll"],"md5sum":"b2c85349569ce17a991baff3fcd127b6","name":"cp049300.exe","release":"2021-08-17T11:10:12","revision":"0","sha1sum":"1c9369015612b4ac9b98c5795e982164838af7bc","size":"7MB","target_guids":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"type_of_change":"1","version":"HPG2"}],"id":{"product":"8ebc8805a4344ec4a24a5c7109c6e07f","version":"4496af98da914abeac467b93da88b675"},"installation":{"command":"cpqsetup.exe","command_params":"","install_caps":{"needuseracct":"no","silent":"yes"},"per_device_install_time_seconds":120,"reboot_details":[{"language":[{"lang":"tw","x_late":"安裝後可能需要重新啟動，更新才會生效，並維持硬體穩定。"},{"lang":"en","x_late":"Reboot may be required after installation for updates to take effect and hardware stability to be maintained."},{"lang":"ko","x_late":"업데이트가 적용되고 하드웨어 안정성이 유지되려면 설치 후 재부팅이 필요할 수 있습니다."},{"lang":"ja","x_late":"アップデートの効果とハードウェアの安定を得るために、インストール後再起動が必要になることがあります。"},{"lang":"cn","x_late":"安装之后必须重启才能使更新生效并保持硬件稳定性。"}]}],"reboot_required":"no"},"installation_dependency":{},"installation_notes":[{"lang":"en","x_late":"<p><strong>To update firmware from Windows operating system on target server:</strong></p>\n\n<ul>\n\t<li>Place the Smart Component in a temporary directory.</li>\n\t<li>Double-click on the Smart Component.</li>\n\t<li>Follow the directions given by the Smart Component.</li>\n</ul>\n\n<p><strong>To use Smart Update Manager from the </strong><a href=\"https://www.hpe.com/servers/spp/download\"><strong>Service Pack for ProLiant</strong></a><strong>:</strong></p>\n\n<ul>\n\t<li>Place the desired firmware to be updated in the directory, \\\\packages.</li>\n\t<li>Run&nbsp;<em>launch_sum.bat</em> script&nbsp;which is found in the root folder of the SPP.</li>\n\t<li>Follow the instructions on the screen.</li>\n</ul>\n"}],"manufacturer_name":[{"lang":"en","x_late":"Hewlett Packard Enterprise"},{"lang":"cn","x_late":"惠普企业"}],"name":[{"lang":"en","x_late":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives"},{"lang":"ja","x_late":"オンラインHDD/SSDフラッシュコンポーネント for Windows(x64)- MK000480GWXFF、 MK000960GWXFH、MK001920GWXFKおよびMK003840GWXFLドライブ"}],"prerequisites":{"required_diskspace":{"size_kb":"3000"},"supported_devices":[{"id":"MK003840GWXFL","target_guid":"4d2340a5-304b-3330-3834-30475758464c","type":"sata"},{"id":"MK001920GWXFK","target_guid":"4d2340a5-304b-3130-3932-30475758464b","type":"sata"},{"id":"MK000960GWXFH","target_guid":"4d2340a5-304b-3030-3936-304757584648","type":"sata"},{"id":"MK000480GWXFF","target_guid":"4d2340a5-304b-3030-3438-304757584646","type":"sata"}],"supported_operating_systems":[{"major":"10","maximumbuild":"17599","minimumbuild":"14393","minor":"0","name":"Microsoft Windows Server 2016","platform":"nt_x86-64","sr":"OEM"},{"major":"10","maximumbuild":"18999","minimumbuild":"17600","minor":"0","name":"Microsoft Windows Server 2019","platform":"nt_x86-64","sr":"OEM"},{"major":"10","minimumbuild":"20317","minor":"0","name":"Microsoft Windows Server 2022","platform":"nt_x86-64","sr":"OEM"}],"supported_platforms":false},"release_date":"2021-09-17T10:49:28","revision_history":[{"lang":"en","latest_enhancements_x_late":"<ul>\n\t<li> Added support for Windows Server 2019.</li>\n</ul>","latest_fixes_x_late":""},{"curr_enhancements_x_late":"<ul>\n\t<li>Added support for Microsoft Server Windows 2022.</li>\n</ul>\n","curr_fixes_x_late":"<p>This&nbsp;FW release deploys an Enhanced Media Scan algorithm that addresses an issue when the host system does not provide enough idle time for drive&rsquo;s Foreground Media Scan to be activated, which is needed to ensure long term drive reliability. It also addresses few minor issues.</p>\n","lang":"en"}],"schema_version":"1.0.0.0","supported_products":[],"sw_keys":[{"name":"MK001920GWXFK","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000960GWXFH","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK003840GWXFL","sw_key_expectedpath":"firmware:sd:SATA"},{"name":"MK000480GWXFF","sw_key_expectedpath":"firmware:sd:SATA"}],"upgrade_requirements":"Recommended"}}]}